ice systems
built
for
the
long
haul.
Download from Www.Somanuals.com. All Manuals Search And Download.
THE LONG HAUL.
Self-Insulated
ABS Evaporator
Housing
Programmable Water
Control
Quick-Change
Merchandising Panel
Nickel-Plated
Copper Evaporator
Front-Mounted LED
Insulated,
Double-Wall
Bulkhead
Future Proof R-404a
Refrigerant
In-Line
Water Pump
Exclusive Ice
Harvest System
Microban®
Antimicrobial
Product Protection
Front Serviceable
*See warranty for details.
Download from Www.Somanuals.com. All Manuals Search And Download.
Series 50†
DIMENSIONS/CAPACITY
C
U
B
E
Model
Nominal
Capacity
Cabinet
Finish
Number
Dimensions
ACS50
46 lbs.
15"w x 24"d x 34"h
E
ARI CERTIFIED PERFORMANCE
Ice Harvest
Rate
lbs. per 24 hrs.
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
Capacity
Storage Bin
(lbs.)
Model
Number
ACS50
38
38.5
14.3
n/a
25
Rated in accordance with ARI Standard 810-91 and 820-88.
34 "
PRODUCTION CHART
AIR-COOLED
R
S
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
70
80
90
46 lbs.
44 lbs.
42 lbs.
41 lbs.
40 lbs.
38 lbs.
40 lbs.
40 lbs.
35 lbs.
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Number Condenser
Refrigerant Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Voltage
Type
Electrical Capacity Fuse Size
Weight
Weight Temperature Temperature Pressure Range
ACS50SL Air-Cooled
R-134a
115/60/1
15
15
110 lbs.
100 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
†Limited lifetime warranty not applicable to this model.
ACS50
Series 200
DIMENSIONS/CAPACITY
Nominal
Capacity
Model
Cabinet
Number
Dimensions
Finish
Polyethylene
SS
IACS224/IWCS224
IACS227/IWCS227
251 lbs
326 lbs
24"w x 24"d x 39"h
27"w x 28"d x 39"h
ARI CERTIFIED PERFORMANCE
39"
Ice Harvest
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Water Use
per 100 lbs.
Capacity
Storage Bin
( lbs.)
Model
Number
Rate
lbs. per 24 hrs.
IACS224
IWCS224
IACS227
IWCS227
150
145
240
240
25.0
22.0
27.0
27.0
10.6
10.5
9.8
n/a
195
n/a
160
77
77
75
75
7.6
Rated in accordance with ARI Standard 810-91 and 820-88.
IACS-224 PRODUCTION CHART
AIR-COOLED
Water Temperature (˚F)
50 70 80
WATER-COOLED
Water Temperature (˚F)
50 70 80
IACS224
Air Temp (˚F)
Air Temp (˚F)
50
70
90
251 lbs. 226 lbs. 214 lbs.
226 lbs. 198 lbs. 177 lbs.
167 lbs. 150 lbs. 137 lbs.
50
70
90
221 lbs. 179 lbs. 171 lbs.
218 lbs. 165 lbs. 155 lbs.
164 lbs. 145 lbs. 130 lbs.
IACS-227 PRODUCTION CHART
AIR-COOLED
Water Temperature (˚F)
50 70 80
WATER-COOLED
Water Temperature (˚F)
50 70 80
39"
Air Temp (˚F)
Air Temp (˚F)
50
70
90
326 lbs. 295 lbs. 271 lbs.
312 lbs. 290 lbs. 267 lbs.
263 lbs. 240 lbs. 220 lbs.
50
70
90
330 lbs. 300 lbs. 270 lbs.
310 lbs. 280 lbs. 260 lbs.
280 lbs. 240 lbs. 230 lbs.
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Refrigerant Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Voltage
Number Condenser
Type
Electrical Capacity Fuse Size
Weight
182 lbs.
182 lbs.
230 lbs.
230 lbs.
Weight Temperature Temperature Pressure Range
IACS224 Air-Cooled
R-404a
115/60/1
115/60/1
115/60/1
115/60/1
15
15
20
20
15
15
20
20
146 lbs.
146 lbs.
198 lbs.
198 lbs.
50°F-100°F
50°F-100°F
50°F-100°F
50°F-100°F
45°F-90°F 20-120 psi 110-126
45°F-90°F 20-120 psi 110-126
45°F-90°F 20-120 psi 110-126
45°F-90°F 20-120 psi 110-126
IWCS224 Water-Cooled R-404a
IACS227 Air-Cooled R-404a
IWCS227 Water-Cooled R-404a
IACS227
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Series 322†
C
U
B
E
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Number
Cabinet
Finish
Water
Electrical Service
Opening
Dimensions
Inlets/Outlets
Drainhose
1
3
3
3
9
9
7
"
"
"
"
SS
SS
" male flare
16" I.D. x 3 " O.D.
" diameter hole
⁄
⁄
⁄
⁄
⁄
⁄
8
AC322
WC322
359 lbs.
341 lbs.
22 w x 23 d x 16
h
h
2
8
8
4
1
3
7
"
"
" male flare
16" I.D. x 3 " O.D.
" diameter hole
⁄
2
⁄
8
⁄
8
⁄
⁄
4
⁄
8
22 w x 23 d x 16
163⁄8
"
397⁄8
"
ARI CERTIFIED PERFORMANCE
KWH
Ice Harvest
Rate
Potable Water
Use
Condenser
Model
Number
Consumption
per 100 lbs.
Water Use
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
AC322
270
270
23.9
23.9
8.7
8.7
n/a
WC322
170
R
S
Rated in accordance with ARI Standard 810-91.
231⁄2
"
PRODUCTION CHART
AIR-COOLED
Water Temperature (˚F)
50 70 80
WATER-COOLED
Water Temperature (˚F)
Air Temp (˚F) 50 70 80
Air Temp (˚F)
50
70
90
359 lbs. 321 lbs. 312 lbs.
333 lbs. 313 lbs. 277 lbs.
305 lbs. 270 lbs. 249 lbs.
50
70
90
341 lbs. 300 lbs. 281 lbs.
326 lbs. 289 lbs. 266 lbs.
315 lbs. 270 lbs. 251 lbs.
AC322/B122AP
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Refrigerant Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Voltage
Number Condenser
Type
Electrical Capacity Fuse Size
Weight
138 lbs.
134 lbs.
Weight Temperature Temperature Pressure Range
AC322 Air-Cooled
WC322 Water-Cooled
R-404a
R-404a
115/60/1
115/60/1
20
20
20
20
122 lbs.
118 lbs.
50°F-100°F
50°F-100°F
45°F-90°F 20-120 psi 110-126
45°F-90°F 20-120 psi 110-126
†Limited lifetime warranty does not apply to this model.
Series 300"Xtreme"
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Number
Cabinet
Finish
Water
Inlets/Outlets
Electrical Service
Opening
Dimensions
Drainhose
23 "
3
9
3
7
XAC322
XAC330
XWC322
XWC330
342 lbs.
342 lbs.
334 lbs.
334 lbs.
22"w x 241 "d x 23"h
" male flare
" male flare
" male flare
" male flare
16" I.D. x " O.D.
" diameter hole
" diameter hole
⁄
2
⁄
8
⁄
⁄
⁄
SS
SS
SS
SS
4
8
1
3
3
3
9
7
7
7
"
"
"
16" I.D. x 3 " O.D.
⁄
⁄
⁄
⁄
⁄
⁄
30 w x 24 d x 23 h
2
8
4
8
1
9
9
"
"
"
16" I.D. x 3 " O.D.
" diameter hole
" diameter hole
⁄
2
⁄
8
⁄
⁄
22 w x 24 d x 23 h
4
8
1
"
"
"
16" I.D. x 3 " O.D.
⁄
⁄
8
⁄
⁄
4
⁄
8
30 w x 24 d x 23 h
2
ARI CERTIFIED PERFORMANCE
Ice Harvest
Rate
71 "
Potable Water
Use
KWH
Condenser
Water Use
per 100 lbs.
Model
Number
Consumption
per 100 lbs.
lbs. per 24 hrs.
per 100 lbs.
XAC322/XAC330
XWC322/XWC330
269
269
16.7
16.7
8.5
6.8
n/a
149
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
AIR-COOLED
WATER-COOLED
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
50
70
90
342
338
285
326
310
269
312
304
258
50
70
90
334
315
299
302
287
281
292
285
268
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant Standard
Circuit Maximum Shipping Operating
Ambient
Water
Water
Voltage
Number Condenser
Type
Electrical Capacity Fuse Size
Weight
148 lbs.
144 lbs.
163 lbs.
155 lbs.
Weight Temperature Temperature Pressure Range
XAC322/XWC322
XAC322 Air-Cooled
XWC322 Water-Cooled
XAC330 Air-Cooled
XWC330 Water-Cooled
R-404a
R-404a
R-404a
R-404a
115/60/1
115/60/1
115/60/1
115/60/1
20
20
20
20
20
20
20
20
123 lbs.
119 lbs.
136 lbs.
128 lbs.
50°F-100°F
50°F-100°F
45°F-90°F 20-80 psi 110-126
45°F-90°F 20-80 psi 110-126
50°F-100°F
50°F-100°F
45°F-90°F 20-80 psi 110-126
45°F-90°F 20-80 psi 110-126
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Series 500"Xtreme"
DIMENSIONS/CAPACITY
PLUMBING
Model
Nominal
Capacity
Cabinet
Finish
Water
Electrical Service
Opening
C
U
B
E
Number
Dimensions
Inlets/Outlets
Drainhose
3
9
9
9
9
9
9
7
XAC522
XWC522
XRC522
XAC530
XWC530
XRC530
600 lbs.
600 lbs.
540 lbs.
540 lbs.
600 lbs.
600 lbs.
22"w x 241 "d x 23"h
SS
SS
SS
SS
SS
SS
" male flare
16" I.D. x 3 " O.D.
" diameter hole
⁄
⁄
⁄
⁄
⁄
2
8
4
8
1
3
7
"
"
"
" male flare
16" I.D. x 3 " O.D.
" diameter hole
⁄
⁄
8
⁄
⁄
⁄
8
22 w x 24 d x 23 h
2
4
1
3
7
"
"
"
" male flare
16" I.D. x 3 " O.D.
" diameter hole
⁄
⁄
8
⁄
⁄
⁄
8
22 w x 24 d x 23 h
2
4
1
3
7
"
"
"
" male flare
16" I.D. x 3 " O.D.
" diameter hole
⁄
⁄
8
⁄
⁄
⁄
8
30 w x 24 d x 23 h
2
4
1
3
7
"
"
"
" male flare
16" I.D. x 3 " O.D.
" diameter hole
⁄
⁄
8
⁄
⁄
⁄
8
30 w x 24 d x 23 h
2
4
23 "
1
3
7
"
"
"
" male flare
16" I.D. x 3 " O.D.
" diameter hole
⁄
⁄
8
⁄
⁄
4
⁄
8
30 w x 24 d x 23 h
2
ARI CERTIFIED PERFORMANCE
Ice Harvest
Rate
Potable Water
Use
per 100 lbs.
KWH
Consumption
per 100 lbs.
Condenser
Model
Number
Water Use
lbs. per 24 hrs.
per 100 lbs.
61 "
XAC522/XAC530
XWC522/XWC530
XRC522/XRC530
475
475
475
17.0
17.0
17.0
6.7
5.8
6.7
n/a
133
n/a
R
S
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
WATER-COOLED
AIR-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
600
597
513
70
80
Air Temp (˚F)
50
540
540
532
70
515
494
475
80
Air Temp (˚F)
50
600
597
513
70
80
50
70
90
596
549
475
542
536
454
50
70
90
489
475
454
50
70
90
596
549
475
542
536
454
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Refrigerant Standard
Circuit Maximum Shipping Operating
Ambient
Water
Voltage
XAC522/XAC530
Number Condenser
Type
Electrical Capacity Fuse Size
Weight
162 lbs.
145 lbs.
165 lbs.
170 lbs.
153 lbs.
180 lbs.
Weight Temperature Temperature Pressure Range
XAC522 Air-Cooled
R-404a
R-404a
R-404a
R-404a
R-404a
R-404a
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
20
20
20
20
20
20
20
20
20
20
20
20
135 lbs.
117 lbs.
141 lbs.
143 lbs.
125 lbs.
149 lbs.
50°F-100°F
50°F-100°F
50°F-100°F
45°F-90°F 20-80 psi 110-126
45°F-90°F 20-80 psi 110-126
45°F-90°F 20-80 psi 110-126
Water-Cooled
XWC522
XRC522 AC Remote*
XAC530 Air-Cooled
XWC530 Water-Cooled
XRC530 AC Remote*
50°F-100°F
50°F-100°F
45°F-90°F 20-80 psi 110-126
45°F-90°F 20-80 psi 110-126
50°F-100°F
45°F-90°F 20-80 psi 110-126
* Use Remote Condenser CR-500.
Series 600"Xtreme"
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Number
Cabinet
Finish
Water
Inlets/Outlets
Electrical Service
Opening
Dimensions
Drainhose
3
9
7
XAC630
XWC630
XRC630
722 lbs.
671 lbs.
722 lbs.
30"w x 241 2"d x 25"h
SS
SS
SS
8 " male flare
⁄
16" I.D. x 3 4 " O.D.
8 " diameter hole
⁄
⁄
⁄
⁄
3
9
9
7
30"w x 241 2"d x 25"h
⁄
8 " male flare
16" I.D. x 3 4 " O.D.
8 " diameter hole
⁄
⁄
⁄
4
⁄
25 "
3
7
30"w x 241 "d x 25"h
" male flare
16" I.D. x 3 " O.D.
" diameter hole
⁄
2
⁄
8
⁄
⁄
⁄
8
ARI CERTIFIED PERFORMANCE
Ice Harvest
Rate
Potable Water
Use
KWH
Condenser
Model
Number
Consumption
per 100 lbs.
Water Use
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
73 "
XAC630
XWC630
XRC630
547
589
547
16.3
17.4
16.3
6.9
5.6
6.9
n/a
116
n/a
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
WATER-COOLED
AIR-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
50 70 80
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
90
722 lbs. 648 lbs.
672 lbs. 609 lbs.
606lbs. 547 lbs.
634 lbs.
589 lbs.
521 lbs.
50
70
90
671 lbs. 603 lbs. 556 lbs.
661 lbs. 594 lbs. 551 lbs.
652 lbs. 589 lbs. 542 lbs.
50
70
90
722 lbs. 648 lbs. 634 lbs.
672 lbs. 609 lbs. 589 lbs.
606 lbs. 547 lbs. 521 lbs.
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Refrigerant Standard
Circuit Maximum Shipping Operating
Ambient
Water
Voltage
Number Condenser
Type
Electrical Capacity Fuse Size
Weight
201 lbs.
197 lbs.
209 lbs.
Weight Temperature Temperature Pressure Range
XAC630 Air-Cooled
XWC630 Water-Cooled
XRC630 AC Remote*
R-404a
R-404a
R-404a
208/230/60/1
208/230/60/1
208/230/60/1
20
20
20
20
20
20
172 lbs.
168 lbs.
180 lbs.
50°F-100°F
50°F-100°F
50°F-100°F
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
XAC630/B530AP
*Use Remote Condenser CR-800.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Series 800"Xtreme"
C
U
B
E
30 "
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Number
Cabinet
Finish
Water
Electrical Service
Opening
Dimensions
Inlets/Outlets
Drainhose
3
9
9
9
7
30"w x 241 2"d x 25"h
SS
SS
SS
8 " male flare
⁄
8 " male flare
" male flare
16" I.D. x 3 4 " O.D.
8 " diameter hole
⁄
⁄
25 "
XAC830
XWC830
XRC830
771 lbs.
780 lbs.
771 lbs.
⁄
⁄
⁄
⁄
⁄
3
7
30"w x 241 2"d x 25"h
⁄
16" I.D. x 3 4 " O.D.
8 " diameter hole
⁄
8
⁄
3
7
30"w x 241 "d x 25"h
16" I.D. x 3 " O.D.
" diameter hole
⁄
2
⁄
⁄
⁄
8
4
ARI CERTIFIED PERFORMANCE
KWH
73 "
Ice Harvest
Rate
Potable Water
Use
Condenser
Model
Consumption
per 100 lbs.
Water Use
Number
XAC830
XWC830
XRC830
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
666
700
666
16.3
17.4
16.3
6.9
5.6
6.9
n/a
116
n/a
R
S
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
WATER-COOLED
AIR-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
50 70 80
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
90
771 lbs. 752 lbs.
747 lbs. 730 lbs.
703 lbs. 666 lbs.
740 lbs.
712 lbs.
621 lbs.
50
70
90
780 lbs. 742 lbs. 715 lbs.
761 lbs. 724 lbs. 693 lbs.
736 lbs. 700 lbs. 676 lbs.
50
70
90
771 lbs. 752 lbs. 740 lbs.
747 lbs. 730 lbs. 712 lbs.
703 lbs. 666 lbs. 621 lbs.
XAC830/B842SS
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Refrigerant Standard
Circuit Maximum Shipping Operating
Ambient
Water
Voltage
Number Condenser
Type
Electrical Capacity Fuse Size
Weight
211 lbs.
207 lbs.
223 lbs.
Weight Temperature Temperature Pressure Range
XAC830 Air-Cooled
XWC830 Water-Cooled
XRC830 AC Remote*
R-404a
R-404a
R-404a
208/230/60/1
208/230/60/1
208/230/60/1
20
20
20
20
20
20
182 lbs.
178 lbs.
194 lbs.
50°F-100°F
50°F-100°F
50°F-100°F
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
*Use Remote Condenser CR-800.
Series 1000"Xtreme"
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Number
Cabinet
Finish
Water
Inlets/Outlets
Electrical Service
Opening
30 "
Dimensions
Drainhose
3
9
9
9
7
XAC1030
XWC1030
XRC1030
950 lbs.
959 lbs.
950 lbs.
30"w x 25"d x 25"h
30"w x 25"d x 25"h
30"w x 25"d x 25"h
" male flare
" male flare
" male flare
16" I.D. x 3 " O.D.
" diameter hole
" diameter hole
" diameter hole
⁄
⁄
⁄
⁄
SS
SS
SS
8
4
8
3
7
16" I.D. x 3 " O.D.
⁄
⁄
⁄
⁄
8
4
8
3
7
16" I.D. x 3 " O.D.
⁄
8
⁄
⁄
4
⁄
8
25"
ARI CERTIFIED PERFORMANCE
KWH
Ice Harvest
Rate
Potable Water
Use
Condenser
Model
Number
Consumption
per 100 lbs.
Water Use
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
XAC1030
XWC1030
XRC1030
830
887
830
13.2
13.2
13.2
7.0
5.5
7.0
n/a
112.7
n/a
73"
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
WATER-COOLED
AIR-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
50 70 80
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
90
950 lbs. 901 lbs.
918 lbs. 877 lbs.
854 lbs. 830 lbs.
890 lbs.
860 lbs.
799 lbs.
50
70
90
959 lbs. 916 lbs. 873 lbs.
939 lbs. 904 lbs. 869 lbs.
900 lbs. 887 lbs. 861 lbs.
50
70
90
950 lbs. 901 lbs. 890 lbs.
918 lbs. 877 lbs. 860 lbs.
854 lbs. 830 lbs. 799 lbs.
SPECIFICATIONS
OPERATING LIMITS
Water
XAC1030/B1048SS
Model
Refrigerant Standard
Circuit Maximum Shipping Operating
Ambient
Water
Voltage
Number Condenser
Type
Electrical Capacity Fuse Size
Weight
226 lbs.
215 lbs.
225 lbs.
Weight Temperature Temperature Pressure Range
XAC1030 Air-Cooled
XWC1030 Water-Cooled
XRC1030 AC Remote*
R-404a
R-404a
R-404a
208/230/60/1
208/230/60/1
208/230/60/1
20
20
20
20
20
20
197 lbs.
186 lbs.
196 lbs.
50°F-100°F
50°F-100°F
50°F-100°F
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
*Use Remote Condenser CR-1200.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Series 1200"Xtreme"
C
U
B
E
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Number
Cabinet
Finish
Water
Inlets/Outlets
Electrical Service
Opening
30 "
Dimensions
Drainhose
3
9
9
9
7
XAC1230
XWC1230
XRC1230
1177 lbs.
1062 lbs.
1177 lbs.
30"w x 241 "d x 28"h
" male flare
" male flare
" male flare
16" I.D. x 3 " O.D.
" diameter hole
" diameter hole
" diameter hole
⁄
⁄
⁄
⁄
⁄
SS
SS
SS
2
8
4
8
3
7
30"w x 241 "d x 25"h
16" I.D. x 3 " O.D.
⁄
⁄
⁄
⁄
⁄
2
8
4
8
3
7
30"w x 241 "d x 25"h
16" I.D. x 3 " O.D.
⁄
2
⁄
8
⁄
⁄
4
⁄
8
25” (water / remote
cooled)
28 " (air-cooled)
ARI CERTIFIED PERFORMANCE
Potable Water
Use
Ice Harvest
Rate
KWH
Condenser
Model
Number
Consumption
per 100 lbs.
Water Use
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
R
S
76 "
XAC1230
XWC1230
XRC1230
1019
1029
1019
14.6
14.6
14.6
6.5
5.2
6.5
n/a
79.8
n/a
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
WATER-COOLED
AIR-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
50 70 80
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
90
1177 lbs. 1137 lbs. 1070 lbs.
1143 lbs. 1098 lbs. 1039 lbs.
1076 lbs. 1019 lbs. 977 lbs.
50
70
90
1062 lbs. 1055 lbs. 1042 lbs.
1059 lbs. 1046 lbs. 1027 lbs.
1052 lbs. 1029 lbs. 1006 lbs.
50
70
90
1177 lbs. 1137 lbs. 1070 lbs.
1143 lbs. 1098 lbs. 1039 lbs.
1076 lbs. 1019 lbs. 977 lbs.
SPECIFICATIONS
OPERATING LIMITS
Water
XAC1230/B1048SS
Model
Refrigerant Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Voltage
Number Condenser
Type Electrical Capacity Fuse Size Weight
Weight Temperature Temperature Pressure Range
XAC1230 Air-Cooled
XWC1230 Water-Cooled
R-404a 208-230/60/1
R-404a 208-230/60/1
20
20
20
20
20
20
258 lbs.
234 lbs.
247 lbs.
229 lbs.
205 lbs.
218 lbs.
50°F-100°F
50°F-100°F
50°F-100°F
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
XRC1230 AC Remote* R-404a 208-230/60/1
*Use Remote Condenser CR-1200.
Series 1400"Xtreme"
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Number
Cabinet
Finish
Water
Inlets/Outlets
Electrical Service
Opening
Dimensions
Drainhose
3
9
9
9
7
XAC1444
1630 lbs.
1505 lbs.
1630 lbs.
44"w x 243 "d x 25"h
" male flare
" male flare
" male flare
16" I.D. x 3 " O.D.
" diameter hole
" diameter hole
" diameter hole
⁄
⁄
⁄
⁄
⁄
SS
SS
SS
4
8
4
8
3
7
1444
XWC
44"w x 243 "d x 25"h
16" I.D. x 3 " O.D.
⁄
⁄
⁄
⁄
⁄
4
8
4
8
3
7
1444
XRC
44"w x 243 "d x 25"h
16" I.D. x 3 " O.D.
⁄
4
⁄
8
⁄
⁄
4
⁄
8
25 "
ARI CERTIFIED PERFORMANCE
KWH
Ice Harvest
Rate
Potable Water
Use
Condenser
Model
Number
Consumption
per 100 lbs.
Water Use
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
XAC1444
XWC1444
XRC1444
1275
1374
1275
14.3
14.3
14.3
6.8
5.5
6.8
n/a
130
n/a
73 "
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
WATER-COOLED
AIR-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
50 70 80
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
90
1630 lbs. 1505 lbs. 1470 lbs.
1537 lbs. 1416 lbs. 1380 lbs.
1340 lbs. 1275 lbs. 1198 lbs.
50
70
90
1505 lbs. 1391 lbs. 1362 lbs.
1473 lbs. 1385 lbs. 1346 lbs.
1409 lbs. 1374 lbs. 1315 lbs.
50
70
90
1630 lbs. 1505 lbs. 1470 lbs.
1537 lbs. 1416 lbs. 1380 lbs.
1340 lbs. 1275 lbs. 1198 lbs.
SPECIFICATIONS
OPERATING LIMITS
Water
XAC1444/B1048SS
Model
Refrigerant Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Voltage
Number Condenser
Type
Electrical Capacity Fuse Size Weight
Weight Temperature Temperature Pressure Range
XAC1444 Air-Cooled
XWC1444 Water-Cooled
XRC1444 AC Remote*
R-404a
R-404a
R-404a
208/230/60/1
208/230/60/1
208/230/60/1
30
30
30
30
30
30
317 lbs.
295 lbs.
308 lbs.
274 lbs.
252 lbs.
265 lbs.
50°F-100°F
50°F-100°F
50°F-100°F
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
*Use Remote Condenser CR-1400.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Series 1800"Xtreme"
C
U
B
E
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Number
Cabinet
Finish
Water
Inlets/Outlets
Electrical Service
Opening
Dimensions
Drainhose
3
9
9
9
7
XAC1844
1947 lbs.
1700 lbs.
1947 lbs.
44"w x 243 "d x 25"h
" male flare
" male flare
" male flare
16" I.D. x 3 " O.D.
" diameter hole
" diameter hole
⁄
⁄
⁄
⁄
⁄
⁄
⁄
⁄
8
SS
SS
SS
4
8
4
8
3
7
1844
XWC
44"w x 243 "d x 25"h
16" I.D. x 3 " O.D.
⁄
⁄
⁄
4
8
4
3
7
1844
XRC
44"w x 243 "d x 25"h
16" I.D. x 3 " O.D.
" diameter hole
⁄
4
⁄
8
⁄
4
⁄
8
25 "
ARI CERTIFIED PERFORMANCE
Potable Water
Use
Ice Harvest
Rate
KWH
Condenser
Model
Number
Consumption
per 100 lbs.
Water Use
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
XAC1844
XWC1844
XRC1844
1600
1610
1600
14.5
14.5
14.5
7.3
6.0
7.3
n/a
150
n/a
73 "
R
S
Rated in accordance with ARI Standard 810-91.
PRODUCTION CHART
WATER-COOLED
AIR-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
50 70 80
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
90
1947 lbs. 1637 lbs. 1328 lbs.
1928 lbs. 1619 lbs. 1309 lbs.
1909 lbs. 1600 lbs. 1290 lbs.
50
70
90
1700 lbs. 1650 lbs. 1610 lbs.
1660 lbs. 1630lbs. 1580 lbs.
1640 lbs. 1610 lbs. 1550 lbs.
50
70
90
1947 lbs. 1637 lbs. 1328 lbs
1928 lbs. 1619 lbs. 1309 lbs.
1909 lbs. 1600 lbs. 1290 lbs.
XAC1844/B1048SS
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Refrigerant Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Voltage
Number Condenser
Type
Electrical Capacity Fuse Size Weight
Weight Temperature Temperature Pressure Range
XAC1844 Air-Cooled
XWC1844 Water-Cooled
XRC1844 AC Remote*
R-404a
R-404a
R-404a
208/230/60/1
208/230/60/1
208/230/60/1
30
30
30
30
30
30
367 lbs.
345 lbs.
358 lbs.
324 lbs.
302 lbs.
315 lbs.
50°F-100°F
50°F-100°F
50°F-100°F
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
45°F-90°F 20-80 psi 198-253
*Use Remote Condenser CR-2400.
Series 2448
DIMENSIONS/CAPACITY
C
H
U
N
K
L
Model
Number
Nominal
Capacity
Cabinet
Finish
Dimensions
IRC2448
IRC2448-3PH
IWC2448
2460 lbs.
2460 lbs.
2534 lbs.
48w x 231 "d x 28"h
SS
SS
SS
⁄
2
48w x 231 "d x 28"h
⁄
2
48w x 231 "d x 28"h
⁄
2
ARI CERTIFIED PERFORMANCE
Ice Harvest
Rate
28"
Potable Water
Use
KWH
Consumption
per 100 lbs.
Condenser
Water Use
Model
Number
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
IRC2448
IRC2448-3PH
IWC2448
2024
2024
2200
15.0
15.0
15.0
8.0
8.0
6.0
n/a
n/a
135
76"
PRODUCTION CHART
48"
REMOTE AIR-COOLED
Water Temperature (˚F)
50 70 80
REMOTE WATER-COOLED
Water Temperature (˚F)
50 70 80
Air Temp (˚F)
Air Temp (˚F)
50
70
90
2460 lbs. 2288 lbs. 2224 lbs.
2401 lbs. 2244 lbs. 2186 lbs.
2163 lbs. 2024 lbs. 1938 lbs.
50
70
90
2534 lbs. 2240 lbs. 2138 lbs.
2500 lbs. 2221 lbs. 2096 lbs.
2283 lbs. 2200 lbs. 2057 lbs.
E
T
S
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Number
Refrigerant Standard Circuit Maximum Shipping Operating Ambient
Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
Water Voltage
IRC2448/B1048SS
Condenser
IRC2448
AC Remote*
R-404a 208-230/60/1
R-404a 208-230/60/3
R-404a 208-230/60/1
30
30
30
30
30
30
396 lbs. 335 lbs. 50°F-100°F
50°F-90°F 20-120 psi 198-235
50°F-90°F 20-120 psi 198-235
50°F-90°F 20-120 psi 198-235
IRC2448-3PH AC Remote*
IWC2448 Water-Cooled
*Use Remote Condenser CR-2400.
396 lbs. 335 lbs. 50°F-100°F
388 lbs. 327 lbs. 50°F-100°F
9
Download from Www.Somanuals.com. All Manuals Search And Download.
141⁄2
"
Series 500
DIMENSIONS/CAPACITY
241⁄2
"
PLUMBING
Model
Nominal
Capacity
Cabinet
Finish
Water
Electrical Service
Opening
C
H
U
N
K
L
Number
Dimensions
141 "w x 25"d x 241 "h
141 "w x 25"d x 241 "h
Inlets/Outlets
Drainhose
1
3
3
7
WCC-500A
WCC-500W
391 lbs.
391 lbs.
SS
SS
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
⁄
⁄
⁄
4
⁄
⁄
⁄
2
2
8
8
" MF / 3 "FPT
" I.D. x 9 16 " O.D.
⁄
" diameter hole
1
7
⁄
2
⁄
2
⁄
4
⁄
⁄
8
⁄
8
8
PRODUCTION CHART
721⁄2
"
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
391 lbs.
369 lbs.
317 lbs.
351 lbs.
329 lbs.
285 lbs.
330 lbs.
310 lbs.
271 lbs.
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Number
Refrigerant Standard Circuit Maximum Shipping Operating
Type
Ambient
Water
Voltage
Condenser
Electrical Capacity Fuse Size Weight
Weight Temperature Temperature Pressure Range
WCC-500A Air-Cooled
Water-Cooled
R-404a
R-404a
115/60/1
115/60/1
15
15
15
15
154 lbs.
154 lbs.
142 lbs.
142 lbs.
50°F-100°F
50°F-100°F
50°F-90°F 20-120 psi 110-126
50°F-90°F 20-120 psi 110-126
WCC-500W
E
T
S
WCC500/B530SS
Series 700
DIMENSIONS/CAPACITY
PLUMBING
Model
Number
Nominal
Cabinet
Finish
Water
Inlets/Outlets
Electrical Service
Opening
Capacity
636 lbs.
636 lbs.
636 lbs.
Dimensions
141 "w x 25"d x 241 "h
Drainhose
1
3
7
" I.D. x 9 16 " O.D.
" diameter hole
241⁄2
"
WCC-700A
WCC-700W
WCC-700R
SS
SS
SS
" male flare
⁄
⁄
⁄
⁄
⁄
⁄
2
2
4
8
8
141 "w x 25"d x 241 "h
" MF / 3 "FPT
" I.D. x 9 16 " O.D.
⁄
" diameter hole
1
3
3
7
⁄
2
⁄
⁄
⁄
⁄
8
⁄
8
2
4
8
141 "w x 25"d x 241 "h
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
1
7
⁄
2
⁄
2
⁄
4
⁄
8
⁄
⁄
8
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
636 lbs.
616 lbs.
570 lbs.
570 lbs.
550 lbs.
513 lbs.
536 lbs.
518 lbs.
489 lbs.
721⁄2
"
SPECIFICATIONS
OPERATING LIMITS
Ambient
Model
Number
Refrigerant Standard
Circuit Maximum Shipping Operating
Water
Water
Voltage
Condenser
Type
Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
WCC-700A Air-Cooled
R-404a
R-404a
R-404a
R-404a
R-404a
115/60/1
115/60/1
20
20
20
20
20
20
20
20
20
20
163 lbs.
163 lbs.
138 lbs.
163 lbs.
163 lbs.
152 lbs. 50°F-100°F
152 lbs. 50°F-100°F
126 lbs. 50°F-100°F
152 lbs. 50°F-100°F
152 lbs. 50°F-100°F
50°F-90°F 20-120 psi 110-126
50°F-90°F 20-120 psi 110-126
50°F-90°F 20-120 psi 110-126
50°F-90°F 20-120 psi 198-253
50°F-90°F 20-120 psi 198-253
Water-Cooled
AC Remote
Air-Cooled
Water-Cooled
WCC-700W
WCC-700R*
WCC-701A
WCC-701W
115/60/1
208-230/60/1
208-230/60/1
*Use Remote Condenser WCU.
WCC700/B842SS
22"
Series 1000
DIMENSIONS/CAPACITY
PLUMBING
27"
Model
Nominal
Capacity
Cabinet
Finish
Water
Inlets/Outlets
Electrical Service
Opening
Number
Dimensions
Drainhose
1
3
3
3
7
WCC-1001A
WCC-1001W
WCC-1001R
1015 lbs.
1015 lbs.
1015 lbs.
22"w x 24"d x 27"h
22"w x 24"d x 27"h
22"w x 24"d x 27"h
SS
" male flare
" I.D. x 9 16 " O.D.
" I.D. x 9 16 " O.D.
⁄
" diameter hole
⁄
⁄
⁄
⁄
4
8
8
1
7
SS
" MF / 3 "FPT
" diameter hole
⁄
⁄
⁄
8
⁄
8
4
8
1
7
SS
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
⁄
4
⁄
8
⁄
⁄
8
PRODUCTION CHART
75"
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
1015 lbs.
940 lbs.
831 lbs.
909 lbs.
839 lbs.
748 lbs.
856 lbs.
790 lbs.
711 lbs.
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Number
Refrigerant Standard
Circuit Maximum Shipping Operating
Ambient
Water
Voltage
Condenser
Air-Cooled
Water-Cooled
AC Remote
Type
Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
R-404a
R-404a
R-404a
208-230/60/1
208-230/60/1
208-230/60/1
15
15
15
15
15
15
210 lbs.
210 lbs.
210 lbs.
194 lbs. 50°F-100°F
194 lbs. 50°F-100°F
194 lbs. 50°F-100°F
50°F-90°F 20-120 psi 198-253
50°F-90°F 20-120 psi 198-253
50°F-90°F 20-120 psi 198-253
WCC-1001A
WCC-1001W
WCC-1001R*
WCC1001/B1048SS
*Use Remote Condenser WC1.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Series 2000
30"
C
H
U
N
K
L
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Number
Cabinet
Finish
Water
Electrical Service
Opening
Dimensions
Inlets/Outlets
Drainhose
28"
1
3
3
3
7
WCC-2001A
WCC-2001W
WCC-2001R
1999 lbs.
1999 lbs.
1999 lbs.
30"w x 24"d x 28"h
30"w x 24"d x 28"h
30"w x 24"d x 28"h
SS
SS
SS
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
⁄
4
⁄
⁄
⁄
8
8
" MF / 3 "FPT
" I.D. x 9 16 " O.D.
⁄
" diameter hole
1
7
⁄
⁄
⁄
8
⁄
8
4
8
1
7
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
⁄
4
⁄
8
⁄
⁄
8
PRODUCTION CHART
76"
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
1999 lbs.
1735 lbs.
1403 lbs.
1790 lbs.
1684 lbs.
1458 lbs.
1201 lbs.
1549 lbs.
1262 lbs.
SPECIFICATIONS
OPERATING LIMITS
Ambient
Model
Refrigerant Standard
Circuit Maximum Shipping Operating
Water
Water
Voltage
Number
Condenser
Air-Cooled
Water-Cooled
AC Remote
Type
Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
R-404a
R-404a
R-404a
208-230/60/1
208-230/60/1
208-230/60/1
15
15
15
15
15
15
342 lbs.
342 lbs.
342 lbs.
317 lbs. 50°F-100°F
317 lbs. 50°F-100°F
317 lbs. 50°F-100°F
50°F-90°F 20-120 psi 198-253
50°F-90°F 20-120 psi 198-253
50°F-90°F 20-120 psi 198-253
WCC-2001A
WCC-2001W
WCC-2001R*
E
T
S
*Use Remote Condenser CR-1200.
WCC2001/B1048SS
Series 200 & Series 525
DIMENSIONS/CAPACITY
Nominal
PLUMBING
Model
Cabinet
Finish
Water
Number
Capacity
Dimensions
Bin Capacity
75 lbs.
Inlets/Outlets
Drainhose
1
1
5
1
"
"
"
"
⁄
2
⁄
2
⁄
4
⁄
8
AF200PSCR
219 lbs.
25"w x 26 d x 40"h
E or SS
male flare
O.D. x
O.D.
40 "
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
219 lbs.
208 lbs.
161 lbs.
188 lbs.
174 lbs.
130 lbs.
175 lbs.
166 lbs.
117 lbs.
F
L
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Refrigerant Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Voltage
Number
Condenser
Type
Electrical Capacity Fuse Size
Weight
Weight
Temperature Temperature Pressure Range
AF200PSCR Air-Cooled
R-404a
115/60/1 15 15
220 lbs.
190 lbs.
50°F-100°F 50°F-90°F 20-120 psi 110-126
AF200PSCR
A
K
E
R
S
DIMENSIONS/CAPACITY
Nominal
PLUMBING
Model
Number
Cabinet
Finish
Water
Condensate
Drain
Capacity
Dimensions
Bin Capacity
175 lbs.
Inlets/Outlets
Bin Drain
3
1
3
1
3
"
"
"
"
4
⁄
⁄
⁄
8
⁄
2
⁄
AF525PSCR
654 lbs.
38 4"w x 26 d x 40"h
E or SS
male flare
O.D. tube
FPT
2
40 "
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
654 lbs.
639 lbs.
562 lbs.
588 lbs.
563 lbs.
479 lbs.
552 lbs.
521 lbs.
448 lbs.
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Number
Refrigerant Standard Circuit Maximum Shipping Operating
Ambient
Water Voltage
Condenser
Type
Electrical Capacity Fuse Size Weight
Weight Temperature Temperature Pressure Range
AF525PSCR Air-Cooled
R-404a
115/60/1 20 20 282 lbs.
240 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
AF525PSCR
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Series 725
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
F
L
Model
Cabinet
Finish
Water
Condensate
Drain
40 "
Number
Dimensions
Bin Capacity
300 lbs.
Inlets/Outlets
Bin Drain
3
1
3
"
"
"
⁄
4
⁄
8
⁄
2
AF725PSCR
654 lbs.
48"w x 30"d x 40"h
E or SS
male flare
O.D. tube
FPT
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
A
K
E
R
S
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
654 lbs.
639 lbs.
562 lbs.
588 lbs.
563 lbs.
479 lbs.
552 lbs.
521 lbs.
448 lbs.
AF725PSCR
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Number
Refrigerant Standard Circuit
Maximum Shipping Operating
Ambient
Water
Voltage
Condenser
Type
Electrical Capacity Fuse Size Weight Weight
Temperature Temperature Pressure Range
AF725PSCR Air-Cooled
R-404a
115/60/1
20
20
334 lbs.
300 lbs.
50°F-100°F 50°F-90°F 20-120 psi 110-126
241⁄2
"
Series 500
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Cabinet
Finish
Water
Inlets/Outlets
Electrical Service
Opening
Number
Dimensions
141 "w x 25"d x 241 "h
Drainhose
1
3
3
7
WCF-510A
WCF-510W
460 lbs.
460 lbs.
SS
SS
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
⁄
⁄
⁄
4
⁄
⁄
⁄
⁄
2
2
8
8
141 "w x 25"d x 241 "h
" MF / 3 "FPT
" I.D. x 9 16 " O.D.
⁄
" diameter hole
1
7
⁄
2
⁄
2
⁄
4
⁄
⁄
8
8
8
721⁄2
"
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
460 lbs.
442 lbs.
407 lbs.
412 lbs.
394 lbs.
367 lbs.
388 lbs.
371 lbs.
349 lbs.
SPECIFICATIONS
OPERATING LIMITS
Ambient
Model
Number
Refrigerant Standard Circuit Maximum Shipping Operating
Water
Water
Voltage
Condenser
Type
Electrical Capacity Fuse Size Weight
Weight Temperature Temperature Pressure Range
WCF-510A Air-Cooled
Water-Cooled
R-404a
R-404a
115/60/1
115/60/1
15
15
15
15
154 lbs.
154 lbs.
142 lbs.
142 lbs.
50°F-100°F
50°F-100°F
50°F-90°F 20-120 psi 110-126
50°F-90°F 20-120 psi 110-126
WCF-510W
Series 700
WCF510/B530SS
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Number
Cabinet
Finish
Water
Electrical Service
Opening
Dimensions
141 "w x 25"d x 241 "h
Inlets/Outlets
Drainhose
1
3
3
3
7
WCF-710A
WCF-710W
WCF-710R
936 lbs.
936 lbs.
936 lbs.
SS
SS
SS
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
⁄
⁄
2
⁄
4
⁄
⁄
⁄
2
8
8
241⁄2
"
141 "w x 25"d x 241 "h
" MF / 3 "FPT
" I.D. x 9 16 " O.D.
⁄
" diameter hole
1
7
⁄
⁄
2
⁄
⁄
⁄
8
⁄
8
2
4
8
141 "w x 25"d x 241 "h
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
1
7
⁄
2
⁄
2
⁄
4
⁄
8
⁄
⁄
8
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
936 lbs.
892 lbs.
779 lbs.
838 lbs.
796 lbs.
701 lbs.
789 lbs.
750 lbs.
667 lbs.
721⁄2
"
SPECIFICATIONS
OPERATING LIMITS
Ambient
Model
Number
Refrigerant Standard
Circuit Maximum Shipping Operating
Water
Water
Voltage
Condenser
Type
Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
WCF-710A Air-Cooled
R-404a
R-404a
R-404a
R-404a
R-404a
115/60/1
115/60/1
20
20
20
20
20
20
20
20
20
20
163 lbs.
163 lbs.
138 lbs.
163 lbs.
163 lbs.
152 lbs. 50°F-100°F
152 lbs. 50°F-100°F
126 lbs. 50°F-100°F
152 lbs. 50°F-100°F
152 lbs. 50°F-100°F
50°F-90°F 20-120 psi 110-126
50°F-90°F 20-120 psi 110-126
50°F-90°F 20-120 psi 110-126
50°F-90°F 20-120 psi 198-253
50°F-90°F 20-120 psi 198-253
Water-Cooled
AC Remote
Air-Cooled
Water-Cooled
WCF-710W
WCF-710R*
WCF-710A
WCF-710W
115/60/1
208-230/60/1
208-230/60/1
*Use Remote Condenser WCU.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
WCF710/B842SS
Series 1000
22"
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
F
L
Model
Cabinet
Finish
Water
Electrical Service
Opening
Number
Dimensions
Inlets/Outlets
Drainhose
27"
1
3
3
3
7
WCF-1101A
WCF-1101W
WCF-1101R
1559 lbs.
1559 lbs.
1559 lbs.
22"w x 24"d x 27"h
22"w x 24"d x 27"h
22"w x 24"d x 27"h
SS
SS
SS
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
⁄
4
⁄
⁄
⁄
8
8
" MF / 3 "FPT
" I.D. x 9 16 " O.D.
⁄
" diameter hole
1
7
⁄
⁄
⁄
8
⁄
8
4
8
1
7
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
⁄
4
⁄
8
⁄
⁄
8
A
K
E
R
S
PRODUCTION CHART
75"
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
1559 lbs.
1426 lbs.
1260 lbs.
1396 lbs.
1314 lbs.
1198 lbs.
1079 lbs.
1273 lbs.
1134 lbs.
SPECIFICATIONS
OPERATING LIMITS
Ambient
Model
Number
Refrigerant Standard
Circuit Maximum Shipping Operating
Water
Water
Voltage
Condenser
Air-Cooled
Water-Cooled
AC Remote
Type
Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
R-404a
R-404a
R-404a
208-230/60/1
208-230/60/1
208-230/60/1
15
15
15
15
15
15
210 lbs.
210 lbs.
210 lbs.
194 lbs. 50°F-100°F
194 lbs. 50°F-100°F
194 lbs. 50°F-100°F
50°F-90°F 20-120 psi 198-253
50°F-90°F 20-120 psi 198-253
50°F-90°F 20-120 psi 198-253
WCF-1101A
WCF-1101W
WCF-1001R*
*Use Remote Condenser WC1.
WCF1101/B1048SS
30"
Series 2000
28"
DIMENSIONS/CAPACITY
Nominal
Capacity
PLUMBING
Model
Cabinet
Finish
Water
Electrical Service
Opening
Number
Dimensions
Inlets/Outlets
Drainhose
D
I
S
P
E
N
S
E
R
S
1
3
3
3
7
WCF-2201A
WCF-2201W
WCF-2201R
2506 lbs.
2506 lbs.
2506 lbs.
30"w x 24"d x 28"h
30"w x 24"d x 28"h
30"w x 24"d x 28"h
SS
SS
SS
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
⁄
4
⁄
⁄
⁄
8
8
" MF / 3 "FPT
" I.D. x 9 16 " O.D.
⁄
" diameter hole
1
7
⁄
⁄
⁄
8
⁄
8
4
8
1
7
" male flare
" I.D. x 9 16 " O.D.
" diameter hole
⁄
4
⁄
8
⁄
⁄
8
76"
PRODUCTION CHART
AIR-TEMPERATURE
WATER-TEMPERATURE
50ºF
70ºF
80ºF
50ºF
70ºF
90ºF
2506 lbs.
2280 lbs.
1901 lbs.
2244 lbs.
2112 lbs.
1916 lbs.
1628 lbs.
2036 lbs.
1711 lbs.
SPECIFICATIONS
OPERATING LIMITS
Water
Model
Number
Refrigerant Standard
Circuit Maximum Shipping Operating
Ambient
Water
Voltage
Condenser
Air-Cooled
Water-Cooled
AC Remote
Type
Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
R-404a
R-404a
R-404a
208-230/60/1
208-230/60/1
208-230/60/1
15
15
15
15
15
15
342 lbs.
342 lbs.
342 lbs.
317 lbs. 50°F-100°F
317 lbs. 50°F-100°F
317 lbs. 50°F-100°F
50°F-90°F 20-120 psi 198-253
50°F-90°F 20-120 psi 198-253
50°F-90°F 20-120 psi 198-253
WCF-2201A
WCF-2201W
WCF-2201R*
WCF2201/B1048SS
*Use Remote Condenser CR1200.
DP-230
Nominal
Storage Capacity
Shipping
Weight
Operating Standard
Method of
Dispensing
Model
Dimensions
Cabinet Finish
Weight
170 lbs.
172 lbs.
170 lbs.
170 lbs.
Electrical
115/60/1
115/60/1
115/60/1
115/60/1
3
3
3
3
200 lbs.
"
"
"
"
All Polyethylene 200 lbs.
All Polyethylene 202 lbs.
All Polyethylene 200 lbs.
All Polyethylene 200 lbs.
Push Button
Coin/Token
⁄
30"w x 30"d x 59
30"w x 30"d x 59
30"w x 30"d x 59
30"w x 30"d x 59
h
h
h
h
8
DPP-230
161467000
161467001
161467002
59 3⁄8
"
200 lbs.
⁄
8
200 lbs.
⁄
8
Key Operated
Card Key
200 lbs.
⁄
8
Bin Drain: 1" vinyl tube
1
Drain Connection: " FPT
⁄
2
Use with any 22" or 30" “I” Series cube icemaker.
DPP-230
13
Download from Www.Somanuals.com. All Manuals Search And Download.
D
I
S
P
E
N
S
E
R
S
D-45
Model
Nominal
Cup
Shipping
Weight
Operating
Weight
Standard
Electrical
28"
Number
Model Dimensions Storage Capacity
Cabinet Finish
Clearance
D-45
45 lbs.
SS cabinet, ABS liner
7"
67 lbs.
53 lbs.
115/60/1
16"w x 22"d x 28"h
3
Drain Connection: " FPT
⁄
4
D-45
ED-150/200/250/300
Model
Number
Nominal
Storage Capacity
Cup
Clearance
Shipping
Weight
Operating Standard
Model Dimensions
Cabinet Finish
Weight
135 lbs.
177 lbs.
180 lbs.
226 lbs.
Electrical
115/60/1
115/60/1
115/60/1
115/60/1
5
ED-150
"
"
"
150 lbs.
SS cabinet, ABS liner
SS cabinet, ABS liner
SS cabinet, ABS liner
SS cabinet, ABS liner
10"
151 lbs.
197 lbs.
201 lbs.
251 lbs.
⁄
22"w x 30"d x 35
30"w x 30"d x 35
h
h
h
8
5
5
ED-200
200 lbs.
10"
⁄
8
ED-250
250 lbs.
10"
⁄
8
30"w x 30"d x 39
5
15
ED-300
"
300 lbs.
10"
⁄
⁄
16
44 8"w x 30"d x 36
h
355⁄8
"
3
"
⁄
4
Drain Connection:
FPT
Use with Cornelius 330, 530, 630, 830, 1030 and 1230 “I” Series cube icemakers.
COMPATIBLE ICEMAKER "X" SERIES
Model
Number 322
522
330
530
630
830
1030
1230
1444
D45
D100
x
x
x
x
ED150
ED200
ED250
ED300
x
x
x
A
C
C
E
S
S
O
R
I
E
S
14
x
x
x
x
x
x
ED-200
Cornelius Bagger
Remote Condensers
• Time-saving
• No mess
• Less melting
• Convenient
• Weatherproof housing
• High-efficiency copper and
aluminum condenser
• Reduces air conditioning
requirements
• Innovative design
Dimensions: 22"w x 101⁄4"d x 281⁄2"h
Shipping weight: 15 lbs.
Cabinet Finish: Galvanized
Model
Standard
Electrical
Shipping
Weight
Operating
Weight
Model
Number
Description
Number
CR-500
CR-800
CR-1200
CR-1400
CR-2400
WC-1
Refrigerant
R-404-A
R-404-A
R-404-A
R-404-A
R-404-A
R-404-A
R-404-A
Dimensions
1
1
1
1
1
3
B28
BG8
TR2
Bagger w/sealing tape dispenser
1000 Count 81 lb. ice bags
Sealing tape (single roll)
115/60/1
72 lbs.
100 lbs.
115 lbs.
130 lbs.
124 lbs.
62 lbs.
68 lbs.
90 lbs.
"
"
"
"
"
⁄
⁄
18 4"w x 14"d x 34
h
h
h
h
h
"
4
1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
115/60/1
⁄
⁄
8
28 2"w x 14"d x 40
1
105 lbs.
115 lbs.
114 lbs.
57 lbs.
⁄
⁄
8
28 2"w x 14"d x 40
1
⁄
⁄
8
28 2"w x 14"d x 40
1
⁄
⁄
28 2"w x 15"d x 37
4
1
1
1
⁄
⁄
⁄
2
21 4"w x 12 4"d x 16
h
1
1
1
WCU
128 lbs.
118 lbs.
"
⁄
h
2
⁄
⁄
18 4"w x 25 4"d x 16
All Cornelius products meet appropriate agency approval, as listed below.
Download from Www.Somanuals.com. All Manuals Search And Download.
B
I
N
S
B122AP
B230AP
B322AP
B430AP
B530AP
B842SS
B1048SS
B1315SBB
FR-300SS with WCF700
• Easy Maintenance Bin
Liners…All rotomolded
polyethylene bin liners will
not crack, chip, dent or rust.
Our seamless design with
large radius corners allows
for easy cleaning and
• Extra Wide Doors…
All Cornelius storage bins
are equipped with full-
width urethane foam
insulated stainless steel
doors with chemical
resistant gasketing.
• Wide Selection…
Twelve models ranging from
120 to 1315 lbs. storage
capacity.
• Corrosion Proof…
All Cornelius storage bins
constructed of rotomolded
polyethylene or 304 grade
stainless steel are virtually
corrosion proof. Our standard
baked enamel finished bins
will provide years of
enhances ice removal.
• Warranty…All Cornelius
storage bins are covered by
our comprehensive product
warranty. Contact your local
Cornelius agent for warranty
details.
• CFC Free Insulation…
All Cornelius bins are
constructed with an average
11⁄ " of rigid CFC free foam
2
insulation, providing superior
insulation efficiency.
corrosion resistant service.
Bin Model
Dimensions
Nominal
*Certified
Storage Capacity Storage Capacity
Cuber Series
Chunklet/Flaker Series
Shipping Weight.
W
22"
30"
22"
30"
30"
42"
48"
48"
261⁄2"
D
29"
H
322 330 522 530 630 830 1030 1230 1444 1844 2448 500 700 1000 2000
x
B122
B230
231⁄2" *
231⁄2"*
48"*
120 lbs.
200 lbs.
300 lbs.
400 lbs.
500 lbs.
800 lbs.
1000 lbs.
1315 lbs.
300 lbs.
90 lbs.
120 lbs.
260 lbs.
290 lbs.
400 lbs.
580 lbs.
670 lbs.
1160 lbs.
260 lbs.
46 lbs.
54 lbs.
29"
1
x
1
1
x
1
x
1
1
B322
313⁄4"
325⁄16"
325⁄16"
32"
1
1
1
1
1
1
1
1
1
1
90 lbs.
B430
38"*
x
x
x
x
x
x
1
1
92 lbs.
B530
48"*
108 lbs.
160 lbs.
182 lbs.
360 lbs.
285 lbs.
B842
48"*
1
1
1
1
x
1
1
x
1
1
x
x
B1048
1315-SBB
FR-300SS
32"
48"*
1
1
x
x
1
34"
68"*
x
x
x
42"
381⁄4"**
x
x
Rated in accordance with ARI standard 820-88.
1 – Top adapter required
– Height dimensions include 6" adjustable legs
*
** – Bin supplied with 5" casters
15
Download from Www.Somanuals.com. All Manuals Search And Download.
MECHANICAL REQUIREMENTS FOR INSTALLATION OF
CORNELIUS ICE MACHINES AND STORAGE BINS
S
P
E
C
I
F
I
C
A
T
I
O
N
LOCATION
Always locate the ice machine where ambient temperatures will not fall below 50˚F nor rise above 100˚F.
CLEARANCE
Always make certain the machine and storage bin will fit through all doors and hallways leading to the final installation site.
When installed, there must be a 6-inch air clearance on rear, top and right side of Cornelius modular icemakers. Air intake and
discharge areas require a 6-inch clearance on all machines. Keep in mind when selecting the icemaker location that modular
machines may be stacked to increase production capacity as requirements grow.
UTILITY CONNECTIONS
Electrical, water and drain connections must be within 6 feet of machine location. All connections must meet national,
state and local codes.
ELECTRICAL REQUIREMENTS
Separate circuits, fuses and/or breakers are required for each icemaker or dispenser. Wire, fuse and circuit breaker sizes must be
calculated by a qualified electrician, based on the model’s specifications and must meet all national, state and local codes.
PLUMBING REQUIREMENTS
Ice machines must always be connected to the building’s cold water supply. For proper operation, water temperatures must not
exceed 45˚F-90˚F and pressure must be within 20-120 psi. Icemaker drain tubing must be a minimum of 1/2" I.D. Bin drain tubing must be
a minimum of 3/4" I.D. Icemaker and bin drains must be vented. Separate drain lines must be used for the icemaker and bin. Water-cooled
condenser drains must not be vented nor connected to icemaker or bin drain lines. All plumbing must meet national, state and local codes.
QUICK REFERENCE SIZING GUIDE BY CUSTOMER VOLUME
Customers
Application
Sizing Guide (daily ice use)
100
250
500
1,000
1,500
(figures below include a 20% safety factor)
Restaurant
1.5 lbs. ice per meal sold
3.0 lbs. ice per seat
180
360
45
—
38
60
90
600
120
1,200
120
450
900
113
—
900
1,800
225
—
188
300
450
3,000
600
6,000
600
1,800
3,600
450
2,700
5,400
675
—
563
Cocktail Bar
Water Glass
Salad Bar
Beverage Only
Beverage Only
Beverage Only
Guest Ice
Hotel Catering
Patient Ice
Cafeteria
6 oz. ice per 12 oz. glass
35 lbs. of ice per cubic foot
5 oz. ice per 7-10 oz. cup
8 oz. ice per 12-16 oz. cup
12 oz. ice per 18-24 oz. cup
5 lbs. per hotel room
1 lb. per person
—
375
600
900
94
150
225
1,500
300
3,000
300
900
1,350
9,000
1,800
18,000
1,800
6,000
1,200
12,000
1,200
G
U
I
10 lbs. per patient
1 lb. per person served
QUICK SIZING GUIDELINES
To determine the ice usage in a bar or restaurant, count the number of chairs for customers, multiply that number by 3 lbs. of ice
per bar stool and 1.5 lbs. per table seat. This should fulfill the customer’s needs, unless they are offering self-serve beverages or there is
an exceptionally large carry-out business. If the carry-out customer is at least one-third of the in-store business, add 1 lb. of ice for
each carry-out customer. Nursing home and hospital ice needs are calculated in much the same way. It is only necessary to count the
number of beds and refer to the following amounts: Hospitals need 10 lbs. of ice per bed; nursing homes require 6 lbs. of ice per bed.
Be sure to take into consideration other uses such as cafeterias and staff dining rooms, provided these areas do not have their own
icemakers. For churches or other places that use ice only once or twice a week, a small production machine on a large bin may be
adequate and economical to fulfill an occasional need for ice. However, if this is done and two meetings are scheduled one after the
other, the machine may not have time to adequately refill the bin before the start of the second engagement. When calculating total
daily ice usage make certain to include all anticipated ice usage. The final step is to consult the Cornelius specification sheets for the
model selected to determine its production capabilities under the operating conditions at the customer’s place of business.
D
E
16
Download from Www.Somanuals.com. All Manuals Search And Download.
CALCULATION METHOD FOR SIZING ICE MACHINES AND STORAGE BINS
S
P
E
C
I
F
I
C
A
T
I
O
N
The quick reference sizing guide works well in many cases; however, more and more customers’ ice needs are changing. Today’s
customers use ice for numerous applications such as product cooling, self-serve beverages, product packaging, display and, in
some cases, retail package sales. To meet customer needs, a more detailed calculation of ice usage and storage requirements is
required. Listed below are the formulas and guidelines for use in these calculations.
SIZING ICE MACHINES
– You need to know the size and quantity of drinks sold. Refer to the following table.
SELF-SERVE BEVERAGES OR CARRY-OUT
This table assumes the cups are completely filled with ice.
Cup Size (fl. oz.)
Average Beverage (fl. oz.)
Average Ice (oz.)
6
3
6
3
6
12
16
20
32
48
8
8
10
16
24
10
16
24
After establishing the number of different sized cups sold in a busy day and multiplying that number by the quantities
indicated, a fairly accurate estimate can be determined. If the establishment uses an ice-cooled beverage dispenser, iced salad
bar or some other type of display that requires ice, the amounts needed are examined separately under the Product
Display/Packing and Coldplate Cooling sections.
– To calculate the amount of ice consumed cooling the coldplate, choose the appropriate operating condi-
COLDPLATE COOLING
tion and multiply by the “average amount of beverage” in the “average cup size.”
EXAMPLE:
Soda/Syrup Inlet Temperature
Find the amount of ice “burned” on a coldplate for a system that has the following
Drinks
per min. 50
operating conditions:
60
70
80
90
100
1.
80˚F inlet soda/syrup temperature
2
4
0.6
1.1
1.7
2.3
2.6
3.4
3.9
1.1
2.3
3.4
4.5
5.6
6.8
7.9
1.7
3.4
5.1
6.8
8.5
2.3
4.5
6.8
9.0
2.8
5.6
8.5
3.4
6.8
10.2
2.
3.
6 vends/minute
18 fl. oz. average amount of beverage drink
6
8
11.3 13.5
Therefore:
10
12
14
11.3 14.1 16.9
13.5 16.9 20.3
15.8 19.7 23.7
From the table choose row “6” and column “80.”
This gives a constant of 6.8.
10.2
11.8
6.8 x 18 = 122.4 lbs./hour
– To size an icemaker to handle product display or packing, it is necessary to determine the
PRODUCT DISPLAY/PACKING
G
U
I
cubic feet of ice needed in 24 hours (length x width x depth). Since the calculations are done using the foot as the standard unit
of measure, the depth must be converted into feet. If the depth is less than 12 inches, divide depth required by 12 to make the
conversion to feet. A cubic foot of ice weighs approximately 35 lbs., so multiply the cubic feet of space to be used for product
display or packing by 35 to determine the ice needs for a 24-hour period.
EXAMPLE:
A supermarket has a fish display case that is 25 feet long and 3 feet deep.
They wish to set the fish in ice to a depth of 6 inches (6 inches = .50 foot).
Ice requirement for 24 hours: 25 ft. x 3 ft. x .5 ft. = 37.5 cu.ft.
37.5 cu. ft. x 35 lbs. = 1,312.5 lbs.
D
E
SAMPLE:
A restaurant has 200 table seats with 4 turns per night, 20 stools at the bar and a salad bar that measures 6 ft. x 3 ft. with a required
ice depth of 4 inches.
General ice usage: 20 (bar stools) x 3 lbs. = 60 lbs.
200 (seats) x 4 (turns) x 1.5 lbs. = 1,200 lbs.
Product display:
6 ft. x 3 ft. x .33 ft. = 5.94 cu. ft.
5.94 cu. ft. x 35 lbs. = 207.9 lbs.
Finally, add all ice usage to determine the requirement for a 24-hour period:
1,200 lbs. + 60 lbs. + 207.9 lbs. = 1,467.9 lbs. ice per day
17
Download from Www.Somanuals.com. All Manuals Search And Download.
The previous sizing methods assume that the icemaker will run continuously 24 hours a day. This total utilization of the icemaker
gives the customer the most cost effective way of producing the required ice. It also requires the bin to be properly sized or the cus-
tomer will run out of ice.
S
P
E
C
I
F
I
C
A
T
I
O
N
The example below shows how two operations can have very different usage patterns, yet still require the same size icemaker.
Convenience Store
400 lbs.
Restaurant
Closed
Monday
Tuesday
Wednesday
Thursday
Friday
400 lbs.
200 lbs.
200 lbs.
200 lbs.
700 lbs.
800 lbs.
700 lbs.
2,800 lbs.
400 lbs.
400 lbs.
400 lbs.
Saturday
Sunday
400 lbs.
400 lbs.
Weekly Total
2,800 lbs.
Using our formula - 2,800 lbs. wkly. usage ÷ 7 days x 1.2 (“safety factor”) = 480 lbs. ice/day
SIZING STORAGE BINS
When ice is used in equal amounts 7 days per week, as in our convenience store example, the storage bin can be sized to
match the production capacity of the icemaker. Each day approximately 500 lbs. will be produced and 500 lbs. will be used.
Some people think that to size the bin they need only match the bin to the highest day’s usage. This will not always work
and often results in a customer running out of ice. If we had used this method for the restaurant example above, we would
have specified an 800 lb. bin. On Friday, the restaurant would have used 700 lbs. of ice, leaving 100 lbs. in the bin. With
Saturday’s production of 500 lbs. we would have only 600 lbs. in the bin — and we would need 800 lbs. — leaving us 200 lbs.
short on Saturday and again on Sunday. The result would be an unhappy customer.
This is the case in our restaurant example. There are three days — Friday, Saturday and Sunday — when the required amount
of ice exceeds the production capacity of the icemaker (these are called “peaks”). In this case, the bin and not the icemaker should
be sized to take care of these “peak” days.
The best way to determine the size bin required is to work backwards from the last “peak” day — in this case Sunday. Take the
amount by which each day’s usage exceeds the 500 lb. daily production of the icemaker.
Sunday usage
Saturday usage
Friday usage
- 700 lbs. = 200 lbs. over production
- 800 lbs. = 300 lbs. over production
- 700 lbs. = 200 lbs. over production
Total = 700 lbs. over production
G
U
I
Add the total (700 lbs.) to the daily production figure (500 lbs.) to get the bin capacity required to meet the restaurant’s
weekend demand for ice. This method tells us we need at least a 1,200 lb. bin.
Once you think you know the size of the bin required, you can check your estimate as follows:
Assuming the bin is empty Sunday evening, 500 lbs. will be produced on Monday with no usage, and another 500 lbs. on Tuesday
for a total of 1,000 lbs. in the bin. Tuesday’s usage of 200 lbs. will lower the bin contents to 800 lbs. but with 500 lbs. of production,
the bin will be full at 1,200 lbs. on Wednesday. The same will be true for Thursday. As we enter the weekend peak period on Friday
we have 1,200 lbs. in the bin from which we will use 700 lbs. This leaves 500 lbs. in the bin, plus 500 lbs. produced in 24 hours for a
total of 1,000 lbs. Saturday’s usage of 800 lbs. reduces the ice available to 200 lbs., plus 500 lbs. of production for a total of 700 lbs. -
exactly the amount needed for Sunday’s usage.
D
E
It’s always a good idea to add the same 20% “safety factor” to the bin as we did to the icemaker. This adjusts for the ice voids
and pyramiding that can occur in the bin. In the case of our restaurant, the addition of the “safety factor” means we would look for
a bin with a storage capacity of approximately 1,400 lbs. (1,200 x 1.2 = 1,440). We can see that an icemaker rated at 500 lbs. of daily
product would easily meet the needs of both of the previous examples, provided that the icemaker runs continuously.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
A GENERAL REVIEW OF THE RULES FOR SIZING ICEMAKERS AND BINS
1. Ice needs are seldom uniform; more ice is generally needed in summer than in winter. Understanding the ice usage of the
customer is a must to assure sufficient ice is available to meet peak demands. Remember, water temperature, as well as the
surrounding air temperature, affects the output capacity of icemakers. Determine what these factors will be during the
peak demand periods. Then verify the icemaker and storage bin selection by the preceding method and refer to the
machine’s production chart to determine the expected capacity under these conditions.
S
P
E
C
I
F
I
C
A
T
I
O
N
2. Determine the size of the icemaker required by dividing the “worst case” week’s total ice usage by seven. Then add in a 20%
“safety factor.”
3. If equal amounts of ice are used each day (including weekends), size the bin to match the ice production.
4. If there are peaks (where a day’s usage exceeds a day’s production), size the bin to store adequate ice to meet the peak
demand(s).
5. Remember that the per pound cost of making ice is about four times the per pound cost of storing ice.
It’s always much less expensive for the customer to meet their “peak” demands by using the storage bin when possible.
6. When sizing the bin, double-check the bin’s true capacity, using the current ARI directory.
7. A final element to take into account is the shape of the bin, the location of the icemaker(s) on the bin, and the size and
location of the icemaker(s’) ice discharge. An ice discharge opening centered on an extremely wide bin will result in much
more pyramiding and, therefore, less storage.
CUBE ICE MACHINES
Model __________ manufactured by IMI Cornelius, rated in accordance with and certified to comply to ARI Standard 810-91,
having a 24-hour production capacity of _________ lbs. at 90˚F air and 70˚F water temperatures. Cubers to be certified to NSF
Standard 12 and display symbol of certifying agency. Ice machines will include, as standard equipment, the following:
•
•
•
•
•
•
•
•
304-grade stainless steel frame assembly and exterior panels.
Built-in water strainer and pressure regulating flow control.
Self-diagnosing solid state microprocessor control system, with programmable flush cycle.
Thermistor-type sensors for uniform ice-thickness control and condenser fan control.
Environmentally safe R-404a refrigerant.
Split-compartment design, isolating critical components of wet environment.
Non-corrosive ABS evaporator compartment.
Epoxy encapsulated proximity switch for harvest termination and full bin control.
ICE STORAGE BIN
Model ________ manufactured by IMI Cornelius, rated in accordance with and certified to comply with ARI Standard 820-88, to
have a storage capacity of _______ lbs. Exterior finish of __________, with interior liner of one-piece seamless roto-molded
polyethylene. Ice machine with storage bin will measure ______" wide, _______" deep and ______" high including 6" adjustable
legs. Storage bin to be certified to NSF Standard 12 and display symbol of certifying agency.
G
U
I
HOSPITALITY DISPENSER
Model ___________ dispenser manufactured by IMI Cornelius, for use with series ____________ cube ice machine. Dispenser to
be rated in accordance with and certified to comply with ARI Standard 820-88, having a storage capacity of _____ lbs. Dispenser will
be equipped to be actuated by __________ (push button, key, room card, coin/token) control. Storage bin to be classified to NSF
Standard 12 and display symbol of certifying agency. The dispenser will include, as standard equipment, the following:
D
E
•
•
•
•
Solid state adjustable portion control.
Adjustable automatic off-cycle agitation.
Interior and exterior roto-molded polyethylene construction.
6-inch adjustable legs.
FLAKE ICE MACHINES
Model ___________ manufactured by IMI Cornelius, having a 24-hour production capacity of ________lbs. at 90˚F air and 70˚F
water temperatures. Flakers to be certified to NSF Standard 12 and display symbol of certifying agency. Flakers will include, as
standard equipment, the following:
•
•
•
300 series stainless steel evaporator.
Top-mounted auger drive mechanism.
Manual reset auger motor overload control.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
CATG 8699
© 2002 IMI Cornelius
Download from Www.Somanuals.com. All Manuals Search And Download.
|