COOPER LIGHTING - SURE-LITES
DIMENSIONS
DESCRIPTION
The Sure-Lites UNH/PLX Series
Exits combine a self powered
emergency exit with-emergency
lighting needs. During the
12 1/4"
emergency mode, the exit has
sufficient capacity to power the
exit as well as the emergency
lighting heads for 90 minutes.
With an extensive range of field
installed accessories, choice of
faces and the variety of
mounting configurations, the
basic exit can be tailored to fit
almost any application.
(311mm)
7 1/2"
(191mm)
12 1/4" (311mm)
UNH/PLX
SERIES
2 1/4" (57mm)
Steel
Self-Powered with
Emergency Heads
INCANDESCENT EXITS
Type
Mounting
Stencil Face, White Finish
Red Letters
Stencil Face, Black Finish
Stencil Face, Blk/Silver Finish
Green Letters Red Letters
Green Letters Red Letters
UNH1SGBDH UNH1SRBSDH
UNH1OFBDH (specify lens)
Green Letters
UNH1SGBSDH
UNH1OFBSDH (specify lens)
Incandescent,
Fluorescent, LED Lamping
Universal(1)
Wall/Ceiling/End UNH1SRWDH UNH1SGWDH UNH1SRBDH
Universal Open Face(2) Wall/Ceiling/End UNH1OFWDH (specify lens)
FLUORESCENT EXITS
EXIT LIGHTING
Universal(1)
Wall/Ceiling/End PLX7202RP
PLX7202GP
PLX7202RB
PLX7202OB (specify lens)
PLX7202GB
PLX7202RBS
PLX7202OBS (specify lens)
PLX7202GBS
Universal Open Face(2) Wall/Ceiling/End PLX7202OP (specify lens)
•
•
•
Dual-voltage input
120/277VAC, 60Hz
LED EXITS
Type
Mounting
Stencil Face, White Stencil Face, White
Stencil Face, Black
Finish, Red Letters
Stencil Face, Black
Finish, Green Letters
20 gauge (white/black)
steel housing
Finish, Red Letters
Finish, Green Letters
Universal
Wall/Ceiling/End
UNH1SRWDHL
UNH1SGWDHL
UNH1SRWBDHL
UNH1SGWBDHL
AC incandescent: (2) 20W
T6 1/2 intermediate base
lamps - DC: two 6V, 3.6W DC
lamps
WATTAGE RATINGS
PLX-7202
UNH
Lead Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs. Nickel Cadmium=24W for 1 1/2 hrs.; 18W for 2 hrs.
Lead Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs. Nickel Cadmium=24W for 1 1/2 hrs.; 18W for 2 hrs.
•
•
AC fluorescent: (2) 5W F5TT
lamps - DC: three 6V, 3.6W
DC lamps
ORDERING INFORMATION
SAMPLE NUMBER: UNH1SRWDHSD
AC LED: long-life LED
lamp modules;
DC: two 6V, 3.6W DC lamps
Model Number
Factory Options
Accessories
Tamperproof Accessories
TPK1CP=Tamperproof
Screws
0590A638SP=Screwdriver
bit for TPK1CP Screws
See chart
(For ordering with incandescent and LED, add
option numbers in order listed after series;
e.g. UNH17090SRBDHL. For ordering with fluorescent
add option numbers in order listed after “PLX7202”;
e.g. PLX720270GP.)
(Order Separately)
FL1=Flasher Kit
BZ1=Buzzer Kit
•
•
Two thermoplastic heads
with matching finish
Pendant Kit
WG2=Wire Guard
VS2=Polycarbonate Vandal
Shield
VS2WP=Polycarbonate
Vandal Shield -
Heads have 6V, 9W wedge
base style lamps (7.2W
on nickel cadmium exits)
PK18-BK=Black, 18" long
PK18-WH=White, 18" long
70=Nickel Cadmium Batteries
20=DC Flasher
30=DC Flasher/Buzzer
Canopy Kit
CAN571=White
CAN578=Black
90=DC Fire Alarm Interface (Incandescent & LED)
SD=Self-Diagnostics (Add to end of catalog number;
e.g. PLX7202RPSD)
•
•
Lead Calcium or Premium
Nickel Cadmium batteries
Weatherproof
Universal: both single and
double face; ceiling, wall and
end mountable
Energy Data
Charge Mode (Fully Discharged Battery) Lead Calcium Battery
Input Power: Input Current (Max.): Power Factor:
120V 277V 120V 277V 120V 277V
Charged Mode (Fully Discharged Battery) Lead Calcium Battery
T.H.D.:
120V 277V
•
•
Knockouts for chevron
directional indicators
Universal styles include
canopy, backplate, and two
stencil faces
Incandescent Exits 20W Lamps
Fluorescent Exits 5W lamps
LED Exits Red
53W
33W
12.6W
15.8W
51W
33W
13.2W
15.4W
.45A
.44A
.11A
.14A
.19A
.18A
.05A
.06A
>.99 >.98
>.62 >.65
>.91 >.91
>.97 >.96
<9% 10%
<10% <10%
<39% <42%
<25% <29%
LED Exits Green
•
Line-latching, Solid-State
voltage limited charger,
Solid-State switching, low-
voltage disconnect,
Standby Mode (Fully Charged Battery) Sealed Nickel Cadmium Battery Input Power consumption is reduced by
approximately 7.5 Watts in the standby operating mode
Sealed Lead Calcium Battery
Incandescent Exits 20W Lamps
Fluorescent Exits 5W lamps
LED Exits Red
47W
26W
9.1W
10.3W
44W
26W
9.1W
10.3W
.40A
.41A
.08A
.09A
.16A
.16A
.04A
.04A
>.98 >.98
>.52 >.57
>.90 >.89
>.96 >.95
<8% <8%
<11% <10%
<36% <40%
<24% <29%
brownout circuit,
overload/short-circuit
protection, test switch/power
indicator light
LED Exits Green
•
UL 924 Listed, life safety
NFPA 101, NEC/OSHA, most
state and local codes
(1) Universal Face Exits include two stencil faces, canopy and backplate. (2) For Open Face Exits, specify lens desired: 004346SP-red letters, white
background; 004347SP - green letters, white background; 004340SP - white letters, red background; 004341SP-white letters, green background;
654 COOPER LIGHTING
Special wording, consult your Cooper Lighting Representative. Order Separately.