Compaq Switch 230934 002 User Manual

StorageWorks by Compaq  
Modular SAN Array Fabric Switch 6  
User Guide  
Part Number 230934-002  
June 2002 (Second Edition)  
This guide is designed to be used as step-by-step instructions for  
installation and as a reference for operation, troubleshooting, and future  
upgrades.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intended Audience............................................................................................................vii  
Important Safety Information ...........................................................................................vii  
Compaq Authorized Reseller ...................................................................................... xi  
Chapter 1  
Overview of the Switch  
The MSA Fabric Switch 6 ...............................................................................................1-2  
Features............................................................................................................................1-3  
Rear View of the Modular San Array 1000.....................................................................1-4  
Installation .......................................................................................................................1-5  
Ethernet RJ-45 Cable ................................................................................................1-5  
DB-9 Serial Cable .....................................................................................................1-5  
Hot-Pluggable ...........................................................................................................1-6  
Modular SAN Array Fabric Switch 6 User Guide  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Chapter 2  
Connecting a Terminal to the Switch ....................................................................... 2-3  
Logging in to the Text-based UI............................................................................... 2-5  
Chapter 3  
Launching the Management Utility................................................................................. 3-3  
Describing the Console ................................................................................................... 3-4  
Task Selection Toolbar............................................................................................. 3-5  
Status Panel............................................................................................................... 3-5  
Main Management Panel.......................................................................................... 3-8  
Using MSA Fabric Switch 6 Management Utility........................................................ 3-15  
Managing and Monitoring Individual Ports............................................................ 3-15  
Managing from the System Information Panel....................................................... 3-31  
Monitoring from the Device View ......................................................................... 3-48  
Session Configuration............................................................................................. 3-49  
Setting up Zoning ................................................................................................... 3-50  
iv  
Modular SAN Array Fabric Switch 6 User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting Guidelines.............................................................................................4-1  
Troubleshooting the MSA Fabric Switch 6 .....................................................................4-2  
Temperature Control........................................................................................................4-8  
Preventative Maintenance Solutions................................................................................4-8  
Regulatory Compliance Notices  
Federal Communications Commission Notice ...............................................................A-1  
Federal Communications Commission Notice ...............................................................A-2  
Modifications ...........................................................................................................A-2  
Cables.......................................................................................................................A-2  
Canadian Notice (Avis Canadien) ..................................................................................A-2  
European Union Notice ..................................................................................................A-3  
Appendix B  
Electrostatic Discharge  
Grounding Methods........................................................................................................ B-2  
Modular SAN Array Fabric Switch 6 User Guide  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Appendix C  
Invoking the Command Line Interface ...........................................................................C-3  
Using the Command Line Interface ................................................................................C-4  
Beacon ......................................................................................................................C-5  
Setting up Zoning..........................................................................................................C-37  
Appendix D  
Laser Precautions and Fibre Cables  
Laser Precautions......................................................................................................D-1  
Fibre Channel Cable .................................................................................................D-2  
Appendix E  
Updating the Fabric Switch MSA Fabric Switch 6 Management Utility  
Finding the MSA Fabric Switch 6 Management Utility Version Number...............E-1  
Downloading the Switch Management Utility Update.............................................E-1  
Updating the Switch using the Web Browser Interface............................................E-2  
Updating the Switch using the Command Line Interface.........................................E-2  
Updating the Switch 6 using the Boot Menu............................................................E-4  
Index  
vi  
Modular SAN Array Fabric Switch 6 User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About This Guide  
This guide is designed to be used as step-by-step instructions for installation and as a  
reference for operation, troubleshooting, and future upgrades.  
Intended Audience  
This guide is intended for readers with a moderate level of SAN and system  
administration experience.  
Important Safety Information  
Before installing this product, read the Important Safety Information document  
provided.  
Symbols on Equipment  
The following symbols may be placed on equipment to indicate the presence of  
potentially hazardous conditions:  
WARNING: This symbol, in conjunction with any of the following symbols,  
indicates the presence of a potential hazard. The potential for injury exists if  
warnings are not observed. Consult your documentation for specific details.  
Modular SAN Array Fabric Switch 6 User Guide  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
About This Guide  
This symbol indicates the presence of hazardous energy circuits or electric  
shock hazards. Refer all servicing to qualified personnel.  
WARNING: To reduce the risk of injury from electric shock hazards, do not  
open this enclosure. Refer all maintenance, upgrades, and servicing to  
qualified personnel.  
This symbol indicates the presence of electric shock hazards. The area  
contains no user or field serviceable parts. Do not open for any reason.  
WARNING: To reduce the risk of injury from electric shock hazards, do not  
open this enclosure  
This symbol on an RJ-45 receptacle indicates a network interface connection.  
WARNING: To reduce the risk of electric shock, fire, or damage to the  
equipment, do not plug telephone or telecommunications connectors into this  
receptacle.  
This symbol indicates the presence of a hot surface or hot component. If this  
surface is contacted, the potential for injury exists.  
WARNING: To reduce the risk of injury from a hot component, allow the  
surface to cool before touching.  
These symbols, on power supplies or systems, indicate that the  
equipment is supplied by multiple sources of power.  
WARNING: To reduce the risk of injury from electric shock,  
remove all power cords to completely disconnect power from the  
system.  
This symbol indicates that the component exceeds the recommended  
weight for one individual to handle safely.  
WARNING: To reduce the risk of personal injury or damage to the  
equipment, observe local occupational health and safety requirements  
and guidelines for manual material handling.  
Weight in kg  
Weight in lb  
viii  
Modular SAN Array Fabric Switch 6 User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About This Guide  
Rack Stability  
WARNING: To reduce the risk of personal injury or damage to the equipment,  
be sure that:  
The leveling jacks are extended to the floor.  
The full weight of the rack rests on the leveling jacks.  
The stabilizing feet are attached to the rack if it is a single-rack installation.  
The racks are coupled in multiple-rack installations.  
Only one component is extended at a time. A rack may become unstable if  
more than one component is extended for any reason.  
Symbols in Text  
These symbols may be found in the text of this guide. They have the following  
meanings.  
WARNING: Text set off in this manner indicates that failure to follow directions  
in the warning could result in bodily harm or loss of life.  
CAUTION: Text set off in this manner indicates that failure to follow directions could  
result in damage to equipment or loss of information.  
IMPORTANT: Text set off in this manner presents clarifying information or specific  
instructions.  
NOTE: Text set off in this manner presents commentary, sidelights, or interesting points of  
information.  
Modular SAN Array Fabric Switch 6 User Guide  
ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
About This Guide  
Text Conventions  
This document uses the following conventions:  
Italic type is used for complete titles of published guides or variables. Variables  
include information that varies in system output, in command lines, and in  
command parameters in text.  
Bold type is used for emphasis, for onscreen interface components (window  
titles, menu names and selections, button and icon names, and so on), and for  
keyboard keys.  
Monospace typefaceis used for command lines, code examples, screen  
displays, error messages, and user input.  
Sans serif typeface is used for uniform resource locators (URLs).  
Related Documents  
For additional information on the topics covered in this guide, refer to the  
following documentation:  
StorageWorks by Compaq Modular SAN Array 1000 User Guide, part number  
230941  
StorageWorks by Compaq Modular SAN Array 1000 Installation Overview,  
part number 230935  
Getting Help  
If you have a problem and have exhausted the information in this guide, you can get  
further information and other help in the following locations.  
x
Modular SAN Array Fabric Switch 6 User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
About This Guide  
HP Technical Support  
In North America, call the HP Technical Support Phone Center at 1-800-652-6727.  
This service is available 24 hours a day, 7 days a week. For continuous quality  
improvement, calls may be recorded or monitored. Outside North America, call the  
nearest HP Technical Support Phone Center. Telephone numbers for worldwide  
Technical Support Centers are listed on the HP website, www.hp.com.  
Be sure to have the following information available before you call HP:  
Technical support registration number (if applicable)  
Product serial number  
Product model name and number  
Applicable error messages  
Add-on boards or hardware  
Third-party hardware or software  
Operating system type and revision level  
HP Website  
The HP website has information on this product as well as the latest drivers and flash  
ROM images. You can access the HP website at www.hp.com.  
HP Authorized Reseller  
For the name of your nearest HP authorized reseller:  
In the United States, call 1-800-345-1518.  
In Canada, call 1-800-263-5868.  
Elsewhere, see the HP website for locations and telephone numbers.  
Modular SAN Array Fabric Switch 6 User Guide  
xi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
1
Overview of the Switch  
This guide provides specific information for installing and configuring the  
MSA Fabric Switch 6 and its component parts.  
Table 1-1: Organization of this Guide  
For information about  
Overview of the Switch  
See  
Chapter 1  
Chapter 2  
Chapter 3  
Chapter 4  
Appendix A  
Appendix B  
Appendix C  
Appendix D  
Appendix E  
Initial Configuration of the Switch  
MSA Fabric Switch 6 Management Utility  
Troubleshooting  
Regulatory Compliance Notices  
Electrostatic Notices  
Command Line Interface  
Laser Precautions  
Updating the MSA Fabric Switch 6 Management  
Utility  
WARNING: To reduce the risk of personal injury or damage to the equipment,  
refer to the user documentation supplied with the server and observe the  
appropriate safety precautions.  
Modular SAN Array Fabric Switch 6 User Guide  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Overview of the Switch  
The MSA Fabric Switch 6  
The MSA Fabric Switch 6 is an integrated six-port module, featuring a 12 Gbps  
switch engine that enables full duplex non-blocking performance on all ports.  
Figure 1-1: The MSA Fabric Switch 6  
1-2  
Modular SAN Array Fabric Switch 6 User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Overview of the Switch  
Features  
The MSA Fabric Switch 6 includes:  
A main board enclosing the 12 Gbps switching engine  
Microprocessor and other hardware logic to support the switch software agents  
MSA Fabric Switch 6 Management Utility  
— Full Duplex Communications - A pair of nodes can simultaneously send and  
receive data for an aggregate of 2 Gbps  
— Automatic Port Bypass - Improves SAN reliability by automatically  
bypassing errant ports  
Global Status Indicator (GSI)  
RS-232 serial interface port for configuring the MSA Fabric Switch 6  
10-base T Ethernet port for communications to host resident management  
software applications  
Null modem cable  
Five external 2/1 Gbps ports, 1 internal 2/1 Gbps port  
Auto switch between 1 and 2 Gbps  
Array Configuration Utility-XE (ACU-XE) configuration support  
Compaq Insight Manager (CIM-XE) launch of the Management Utility  
Modular SAN Array Fabric Switch 6 User Guide  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Overview of the Switch  
Rear View of the Modular San Array 1000  
Figure 1-2 is an illustration of the rear panel of the MSA1000 with an MSA Fabric  
Switch 6 installed.  
3
2
1
4
Figure 1-2: MSA1000 rear panel with a Fabric Switch 6  
Item  
Description  
Function  
Œ
Port Link Indicators  
See indicators table in Chapter 4,  
“Troubleshooting.”  

RS-232 DB-9 Serial  
Port  
A male serial port that may be  
connected to a host system with a  
standard 9-pin female to 9-pin female  
null modem cable. This port can be  
used to perform initial configuration or  
local management diagnostic tasks.  
RJ-45 Ethernet  
connector  
Ethernet connector to connect the  
device to a network for management  
purposes.  
Global Status  
Indicator  
The Global Status Indicator provides a  
visual reference to the status of the  
switch. See the indicators table in  
Chapter 4, “Troubleshooting,” for more  
information.  
1-4  
Modular SAN Array Fabric Switch 6 User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Overview of the Switch  
Installation  
Before the MSA Fabric Switch 6 can communicate with Compaq-managed devices,  
all devices must be properly connected and powered on.  
Ethernet RJ-45 Cable  
This connector is provided for management through Simple Network Management  
Protocol (SNMP). By default, the MSA Fabric Switch 6 is configured to use an IP  
address of 127.0.0.1. To change this IP address, use ACU-XE, a terminal, or a  
terminal emulator connected to the DB-9 serial port. Refer to Chapter 2, Initial  
Configuration of the Switch,for more detailed information on this subject.  
DB-9 Serial Cable  
This connector is provided for advanced configuration and management.  
The MSA Fabric Switch 6 is designed to function directly out of its shipping  
container with no special configuration required. However, you have the ability to  
configure and monitor various aspects of the MSA Fabric Switch 6 by using  
ACU-XE or CIM-XE or by connecting a terminal or terminal emulator to the serial  
port. See Chapter 2, Initial Configuration of the Switch,for more information on  
using this interface.  
Modular SAN Array Fabric Switch 6 User Guide  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Overview of the Switch  
Hot-Pluggable  
The MSA Fabric Switch 6 is hot-pluggable. The unit can be installed and replaced  
without power-cycling the MSA1000.  
When adding or replacing a switch, allow sufficient time to complete the power-on  
self-tests (POST) and configuration tasks before using.  
To power on the unit properly:  
1. Power on the MSA1000.  
On power up, the switch will run several POST tests and the GSI indicator will  
display changing patterns (refer to the section Reading the Global Service  
Indicatorin Chapter 4, Troubleshooting).  
2. Power on I/O device(s).  
3. Verify that the storage device(s) are visible to the host(s).  
4. Start Applications.  
Before the MSA Fabric Switch 6 can communicate with Compaq-managed devices,  
all devices must be properly configured, connected, and powered up. See Chapter 2,  
Initial Configuration of the Switch,for installation instructions.  
1-6  
Modular SAN Array Fabric Switch 6 User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
Initial Configuration of the Switch  
This chapter details the procedures used to initially configure the MSA Fabric  
Switch 6. Preliminary switch configuration includes entering the Ethernet and the  
SNMP settings.  
Two configuration methods are available:  
Using the text-based user interface to configure the switch  
Using the Array Configuration Utility-XE (ACU-XE) to configure the switch  
Modular SAN Array Fabric Switch 6 User Guide  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Initial Configuration of the Switch  
Configuration Overview  
When a switch is initially connected to a network, the network does not recognize it  
and does not know its IP address. Accessing the switch and entering the Ethernet and  
SNMP settings assigns the switch a location and makes it available to the network.  
After the switch is accessible, additional parameters must be entered. These  
secondary configuration tasks can be performed from four different user interfaces,  
including the text-based user interface (text-based UI), Command Line Interface  
(CLI), the ACU-XE, and the Compaq MSA Fabric Switch 6 Management Utility.  
The text-based UI can be used for the initial configuration tasks and the CLI can be  
accessed from this interface to perform advanced configuration tasks.  
The CLI of the switch provides access to extensive management and monitoring  
functions and is available directly through the serial port in the front of the switch or  
remotely through the switch’s Ethernet interface using telnet. During initial set-up, it  
is accessed through the text-based UI. Subsequently, the system defaults to the CLI  
or the text-based UI, depending on which interface was used last. For information on  
the CLI, refer to Appendix C, “Command Line Interface.”  
The ACU-XE is a web-based user interface primarily used to configure the array  
controllers and hard drive arrays of the MSA1000. In addition, the ACU-XE can be  
used to configure the switch. Instructions for configuring the switch using the  
ACU-XE are included in this chapter. For information on using the ACU-XE to  
configure the storage, refer to the StorageWorks by Compaq Modular SAN Array  
1000 User Guide or the Compaq Array Configuration Utility XE User Guide.  
The MSA Fabric Switch 6 Management Utility provides most of the functions  
available in the text-based UI and the CLI, but in a user-friendly, web-based,  
graphical interface. It is accessible from Compaq Insight Manager (CIM-XE) or any  
workstations equipped with a web browser. For more information, refer to  
www.compaq.com/storageworks.  
2-2  
Modular SAN Array Fabric Switch 6 User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Initial Configuration of the Switch  
Using the Text-based UI to Configure the Switch  
The text-based UI of the switch is available directly through the serial port in the  
front of the switch. After the Ethernet settings are entered, the text-based UI can be  
accessed remotely through the switch’s Ethernet interface using telnet. With the  
following exceptions, all functions of the menu interface are available either directly  
or through telnet.  
The telnet interface is available only after the MSA Switch is completely booted.  
This means the results of the initialization tests are not viewable and if a reset is  
issued, the telnet connection is terminated.  
Users are unable to change the password over the telnet interface.  
Another difference between using the serial port interface and telnet is that when  
using telnet, you can only get access to the switch after it has started up and has  
initialized its network parameters. Consequently, you must have a directly-connected  
terminal to initially configure network parameters and to view the power-up  
information of the MSA Switch.  
Connecting a Terminal to the Switch  
NOTE: This process uses a computer running on Microsoft Windows NT 4.0 or later.  
However, the switch can communicate with any operating system that utilizes a terminal  
emulator. If your computer uses another operating system, be sure that the baud rate, data  
bits, stop bits, parity, and terminal emulation are set for the selected serial port as specified in  
this procedure.  
To directly connect a terminal to the MSA Switch:  
1. Make sure there is power to the switch and attach a terminal or terminal  
emulator.  
2. Connect a server serial port to the switch’s DB-9 serial port.  
3. Power on the server (if it is not already on).  
4. Access the terminal emulator on the server. In Windows NT 4.0, select  
StartProgramsAccessoriesHyperTerminal  
Modular SAN Array Fabric Switch 6 User Guide  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Initial Configuration of the Switch  
5. Set up the properties for the terminal connection.  
In Windows NT 4.0:  
a. Double-click the Hypertrm icon.  
b. Enter a name for the connection in the New Connection dialog box, select an  
icon to represent the switch for future use, and click OK.  
The Connect To dialog box is displayed.  
6. From the Connect using drop-down menu, select the communications port  
assigned to the serial port (for example, COM1, COM2) and click OK. In the  
properties dialog box, enter the following port settings and select OK.  
Table 2-1: Default Serial Port Settings  
Type  
Setting  
38,600  
8
Bits per second (baud rate)  
Data bits  
Parity  
None  
1
Stop bits  
Flow control  
None  
7. Select FileProperties to show the connection properties dialog box. Select the  
Settings tab. From the Emulation pull-down menu, select VT100 and click OK.  
8. Power ON all peripheral device(s).  
9. Wait at least ten seconds and power cycle the MSA1000. The switch sends a  
series of Power-on Self-Test (POST) messages in HyperTerminal.  
2-4  
Modular SAN Array Fabric Switch 6 User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Initial Configuration of the Switch  
Logging in to the Text-based UI  
Upon connection to the switch or completion of the start-up sequence, you must log  
into the MSA Switch to access the management functions. To do this, you must login  
as “user” and enter the password assigned to the switch.  
The default login variables assigned at the factory are:  
Login: user  
Password: ADMIN  
To access the text-base UI:  
1. At the Login prompt, enter user as the login variable.  
>Login: user  
2. At the password prompt, enter the assigned password.  
>Password: ADMIN  
Upon successful login, the main menu is displayed. Figure 2-1 is an illustration  
of the initial Login menu.  
Figure 2-1: Login menu  
The main menu contains a brief summary of the status of the switch, including the  
model number, the firmware version, and whether it passed its self-test.  
NOTE: If the text-based UI from the previous connection was logged out while in the CLI, the  
CLI prompt is displayed. To return to the text-menu interface from the CLI prompt, enter exit at  
the prompt.  
Modular SAN Array Fabric Switch 6 User Guide  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Initial Configuration of the Switch  
Accessing Networking Parameters  
Select option 2. Networking parameters to access the Network Parameter menu,  
which is shown Figure 2-2. The first option in this menu allows the user to return to  
the main menu. Any changes made are reset to the previous value.  
The second, third, and fourth parameters are used to configure the Ethernet settings  
for the MSA Switch. All these parameters must be set appropriately for the site  
before the MSA Switch can be managed over the Ethernet and connected to using  
telnet.  
Figure 2-2: Network Parameters menu  
2-6  
Modular SAN Array Fabric Switch 6 User Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.