Chief Manufacturing TV Mount 8805 000009 User Manual

I N S T R U C T I O N  
M A N U A L  
Plasma Display  
Electric  
Pop-Up Lift (PUL)  
Your Plasma Display Electric Pop-Up Lift is designed for  
installation in furniture or cabinets. Display mounting is  
made easy using the Q-latch mounting system and your  
PUL provides a smooth, quiet and reliable lift for your dis-  
play.  
The versatile Q-latch system not only makes mounting  
safe and easy, it makes changing display makes and mod-  
els quick and inexpensive. Simply install the PSB mount-  
ing bracket designed specifically for the display and mount  
it on the PUL.  
Superior performance and dependability are designed into  
your PUL. The lift is made using heavy duty steel and alu-  
minum extrusion construction. All electrical components  
are UL/TUV listed and the use of low voltage, solid state  
circuitry controls ensure safety and reliability.  
BEFORE YOU BEGIN  
CAUTION: To prevent damage to the PUL, which could affect or void the Factory warranty, thoroughly  
study all instructions and illustrations before you begin to install or operate the unit. Pay particular atten-  
tion to the “Important Precautions” on Page 1.  
• If you have any questions about this installation, contact Chief Manufacturing at 1-800-582-6480.  
PART NO. 8805-000009 (Rev. C)  
CHIEF MANUFACTURING INC.  
©2000 Chief Manufacturing  
1-800-582-6480 952-894-6280 FAX 952-894-6918  
8401 EAGLE CREEK PARKWAY, STE. 700  
SAVAGE, MINNESOTA 55378 USA  
05-05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
CONTENTS  
WEIGHT, SIZE, AND VERTICAL  
TRAVEL SPECIFICATIONS ............................. 3  
INSPECT AND TEST THE UNIT  
Inspect The Unit ................................................... 5  
Test The Unit ....................................................... 5  
PREPARE THE FURNITURE/CABINET  
General Guidelines ............................................... 6  
Retracted Position Finish Piece Option ............... 7  
Attach Brackets to the Display ............................ 10  
Mount the Display ............................................... 10  
ADJUSTMENTS ................................................. 11  
Width Adjustment ................................................ 11  
Adjust Vertical Travel .......................................... 11  
Pushbutton ........................................................... 13  
Extend and Retract Terminals to beTriggered by  
Separate Dry Contacts ......................................... 13  
12 Volt Out Supply .............................................. 17  
24 Volt Out Supply .............................................. 17  
Two Dry Contact Closures .................................. 17  
TROUBLESHOOTING .......................................... 19  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
3. Determine the inside dimensions available in your furniture/  
Table 1: Weight, Size, and Vertical Travel  
Lift  
Capacity  
Outside  
Dimensions  
Max. Equipment Size  
HxWxD  
Vertical  
Travel  
Model  
230Lbs  
104.3Kgs  
33.75”x7.7”  
(857.3mmx195.6mm)  
25.5”x54.125”x6.5”  
(647.7mmx1374.8mmx165.1mm)  
28”  
711.2mm  
PUL4228  
PUL4233  
230Lbs  
104.3Kgs  
38.75”x7.7”  
(984.3mmx195.6mm)  
30.5”x54.125”x6.5”  
(774.7mmx1374.8mmx165.1mm)  
33”  
838.2mm  
230Lbs  
104.3Kgs  
44.75”x7.7”  
(1136.7mmx195.6mm)  
36.5”x54.125”x6.5”  
(927.1mmx1374.8mmx165.1mm)  
39”  
990.6mm  
PUL4239  
PUL4245  
PUL4251  
PUL4257  
230Lbs  
104.3Kgs  
50.75”x7.7”  
42.5”x54.125”x6.5”  
45”  
1143.0mm  
(1289.1mmx195.6mm) (1079.5mmx1374.8mmx165.1mm)  
230Lbs  
104.3Kgs  
56.75”x7.7”  
48.5”x54.125”x6.5”  
51”  
1295.4mm  
(1441.5mmx195.6mm) (1231.9mmx1374.8mmx165.1mm)  
230Lbs  
104.3Kgs  
62.75”x7.7”  
54.5”x54.125”x6.5”  
57”  
1447.8mm  
(1593.9mmx195.6mm) (1384.3mmx1374.8mmx165.1mm)  
Table 2: Adjustable Width  
Model  
Outside  
Inside  
44.125” to 56.125”  
1120.8mm to 1425.6mm  
42.125” to 54.125”  
1070.0mm to 1374.8mm  
PUL4228  
PUL4233  
44.125” to 56.125”  
42.125” to 54.125”  
1120.8mm to 1425.6mm  
1070.0mm to 1374.8mm  
PUL4239  
PUL4245  
PUL4251  
PUL4257  
44.125” to 56.125”  
1120.8mm to 1425.6mm  
42.125” to 54.125”  
1070.0mm to 1374.8mm  
44.125” to 56.125”  
1120.8mm to 1425.6mm  
42.125” to 54.125”  
1070.0mm to 1374.8mm  
44.125” to 56.125”  
1120.8mm to 1425.6mm  
42.125” to 54.125”  
1070.0mm to 1374.8mm  
44.125” to 56.125”  
42.125” to 54.125”  
1120.8mm to 1425.6mm  
1070.0mm to 1374.8mm  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
DIMENSIONAL DRAWING  
See Table 1 on page 3 for outside adjustable width, dimension “H” and dimension “W”.  
Front View  
Side View  
1.48  
24.25  
11" MAX  
4" MIN  
ADJUSTMENT  
2.459  
5.000  
2.3  
4.88  
DIMENSION "H"  
OUTSIDE  
ADJUSTABLE  
7.730  
WIDTH  
44.125 NIM - 56.125 MAX  
26.5  
5.0  
Top View  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
INSPECT AND TEST THE UNIT BEFORE INSTALLING  
Inspect The Unit  
1. Carefully inspect the Plasma Display Electric Pop-Up Lift  
(PUL) for shipping damage. If any damage is apparent, call  
your carrier claims agent and do not continue with the installa-  
tion until the carrier has reviewed the damage.  
NOTE: Read all assembly instructions before starting assem-  
bly.  
2. Carefully inspect PUL components for damage, checking verti-  
cal extrusion arms to make sure they are parallel.  
Figure 1. Connection to Housing  
IMPORTANT: Before mounting the lift in the furniture/cabinet,  
make the following tests to be sure that it operates properly and has  
not been damaged in shipping.  
Test The Unit  
1. Set the PUL on a clean, level surface.  
2. Connect the motor control box to the control circuit housing  
(see Figure 1, Figure 2, and Figure 3).  
3. Install two terminal blocks in control box (see Figure 2).  
Figure 2. Front Connection to Control Box  
NOTE: The lift is supplied with a momentary push button on  
the end of a cable to help you pretest the operation.  
3. Connect the momentary push button (provided) cable leads to  
terminals #6 and #1 and add a jumper wire (provided - electri-  
cal wire about 4 in. long with 1/4 in. stripped at each end)  
between terminals #2 and #5 on the same terminal block (see  
Fig. 4).  
4. Plug the lift’s power cord (see Figure 3) into a 110V 60 Hz or  
220V 50 Hz (as appropriate) 15-amp outlet.  
NOTE: The lift draws approximately 1.5 amps.  
Figure 3. Back Connection and Power Cord  
to Control Box  
WARNNG: Be aware during the  
installation that this is a motorized  
device, and there are pinch points for  
people and for electrical wiring.  
Keep hands and electrical wiring  
away from internal components of  
the mechanism  
To  
5. Operate the lift much like a garage-door opener: press the but-  
ton when the lift is at its “bottom” position and it will move  
“up”; press again when it is at its “top” position and it will  
move “down”; press while moving and it will stop.  
Use the push button to check that the lift runs to the top and  
bottom of its travel without any interference that might indicate  
damage during shipment.  
To push button  
To jumper  
6. Unplug the lift’s power cord.  
Figure 4. Test Wiring  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
PREPARE THE FURNITURE/CABINET AND INSTALL THE LIFT  
Because of the wide variety of possible mounting situations, Chief Manufacturing can only provide general guidelines  
for lift installation. Study the following information carefully, and adapt it as necessary to fit your specific installation.  
WARNING: Be especially aware of the weight of the unit, and  
the potential for personal injury or of damage to the unit if it is  
not adequately mounted. The lift (without a projector) weighs  
approximately 150 lbs (68 kg).  
The “General Guidelines” below and the information on the following pages cover the most common mounting situa-  
tions:  
General Guidelines  
Compare the inside dimensions of the furniture/cabinet in which the lift will be installed with the dimensional requirements of  
your display and any additional space required for your application. Allow for movement of the lift and the display.  
Prepare the Furniture/Cabinet  
WARNNG: Be aware during the instal-  
lation that this is a motorized device,  
and there are pinch points for people  
and for electrical wiring. Keep hands  
and electrical wiring away from inter-  
nal components of the mechanism  
1. Determine size and weight of display to be lifted. See  
limitations.  
2. Determine vertical travel height required for presentation  
viewing. See Table 1 for height limitations.  
Furniture Opening Finish Piece Options  
Because of the wide variety of possible mounting sit-  
uations, Chief Manufacturing can only provide gen-  
eral guidelines for finish options. Study the following  
information carefully, and adapt it as necessary to fit  
your specific installation.  
NOTE: Always leave access to the lift for maintenance pur-  
poses.  
Extended Position Finish Piece Option  
A finish piece, covering the opening when the unit is  
in the fully extended position, may be installed for  
estetic purposes. Using the material cut slight smaller  
than the opening size, install the finish piece as fol-  
lows:  
1. Measure the width of the finish piece.  
2. Measure the distance between the verticle extrusion arms and  
subtract a nominal amount for clearance.  
CAUTION: Failure to allow clearance for the finish piece to  
retract to the fully lowered position may result in damage to the fin-  
ish piece, damage to the lift, and damage to the plasma.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
3. Make sure the finish piece measured in step 1 is smaller than  
the clearance distance measured in step 2 and note any cord  
management access holes that may be necessary.  
4. Measure the thickness of the finish piece, add this thickness to  
the length of the five capscrews used to secure the plasma  
mounting assembly when a backing is not used, and obtain the  
five longer 3/8-16 capscrews for assembly with backing.  
5. Place the finish piece on the shelf, making sure it is correctly  
positioned to allow clearance when lowered, and transfer the  
pattern of the five access holes onto the finish piece.  
Plasma Mounting  
Assembly  
Shelf  
6. Drill five through holes, with clearance for 3/8” bolts, in the  
finish piece and any cord management holes that may be nec-  
essary.  
7. Place the finish piece on the shelf.  
8. Place the plasma mounting assembly on top of the finish piece  
(see Figure 5).  
Figure 5. Plasma Mounting Assembly  
9. Using a 5/16” Allen wrench inserted through the five access  
holes on the bottom of the shelf (see Figure 6), install five  
longer 3/8-16 cap screws.  
10. With the aid of another person, lift the display up to the mount,  
aligning the PSB mounting buttons on the display with the  
teardrop slots on the mount, set the plasma into place and  
adjust mounting assembly to ensure proper clearance is  
achieved.  
Access Holes  
11. Measure and record clearance dimensions and, with the aid of  
another person, remove plasma.  
WARNNG: Be aware during the installa-  
tion that this is a motorized device, and  
there are pinch points for people and for  
electrical wiring. Keep hands and electri-  
cal wiring away from internal components  
of the mechanism  
Figure 6. Access Holes  
12. Carefully, without plasma mounted on lift, operate lift to  
ensure finish piece has sufficient clearance during full travel.  
Retracted Position Finish Piece Option  
A finish piece, covering the opening when the unit is  
retracted, may be installed for estetic purposes. Install  
the finish piece as follows:  
1. Complete the instructions in “Extended Position Finish Piece  
2. Cut two side pieces, matching the width of the extended posi-  
tion finish piece, to a length slightly longer than the distance  
the plasma will travel (this will be trimmed later).  
3. Cut a top piece, matching the dimensions of your extended  
position finish piece (see Figure 7).  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
4. With the extended position finish piece and the plasma-  
mounted, lower the unit to its fully retracted position.  
Retracted Position  
Finish Piece  
Backing  
5. Place the side pieces in position (do not attach).  
6. Place the top piece in position (do not attach).  
7. Measure the distance from the top surface of the top piece to  
the top surface of your furniture and cut this dimension from  
each side piece (see Figure 8).  
Side Pieces  
8. Remove and assemble finish pieces (bottom, sides and top),  
making sure your finished box is square.  
Plasma  
CAUTION: A backing is recommended for support. Frame move-  
ment could result in damage to the frame, damage to the lift, and  
damage to the plasma.  
Extendeded Position  
Finish Piece  
CAUTION: Check plasma ventilation requirements. Provide ven-  
tillation for your application.  
9. Measure box, construct a backing for lateral support, and  
install backing.  
Figure 7. Retracted Position Finish Piece  
WARNNG: Be aware during the installation that this is a  
motorized device, and there are pinch points for people and for  
electrical wiring. Keep hands and electrical wiring away from  
internal components of the mechanism  
CAUTION: Failure to allow clearance for the finish pieces to  
retract to the fully lowered position may result  
in damage to the finish pieces, damage to the  
lift, and damage to the plasma.  
Finish Piece  
10. Carefully, without plasma mounted on  
lift, operate lift to ensure the finish pieces  
have sufficient clearance during full travel  
and that top finish piece is flush with the furniture top when  
fully retracted.  
Furniture  
Figure 8. Side Piece Dimensions  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
Install the PUL into the Cabinet  
1. Adjust motor/control box unit (see Figure 9).  
NOTE: The motor/control box unit is factory set to the nar-  
rowest horizontal position.  
a. Loosen the six 5/16”-18X5/8” hex head bolts on the front  
of each half of the motor/control box and eight 1/4-20  
socket head allen screws (4 front and 4 back) on the  
bracket mounting crossbrace. Slide both halves of the lift  
all the way in and out to ensure the lift can be adjusted  
freely.  
Eight 1/4-20 Socket  
Head AllenScrews  
c. Measure the width of the inside enclosure where the lift  
will be mounted.  
Bracket Mounting Crossbrace  
Six Hex Head Bolts  
d. Adjust the width of the lift, allowing for clearance, and  
hand tighten all bolts loosened in step a.  
Motor/Control Box  
NOTE: The unit must be installed square and parallel in ALL  
dimensions for smooth and reliable operation. The extrusions  
housing the chains must also remain exactly square to the  
power box and parallel to each other after it has been installed.  
Shims may be required between the unit and the enclosure to  
maintain parallel dimensions between the extrusions.  
Figure 9. Motor/Control Box  
2. Place the unit into the enclosure so the load to be lifted is cen-  
tered over the vertical extrusion beams.  
Optional holes requiring spacers between  
the lift and the bottom of the enclosure  
3. With the lift in place, use the base of the lift mechanism as a  
template to transfer 4 holes (17/64” diameter) to the enclosure  
bottom.  
NOTE: If desired, you can use the additional four holes in the cor-  
ners of the lift, but you must fill the space between the lift and  
enclosure bottom to prevent warping.  
4. Remove the lift mechanism from the enclosure.  
5. Drill the 4 holes (17/64” diameter) in the bottom of the enclo-  
sure.  
Thru bolt, two fender washers  
and Nyloc Nut two places  
each side  
6. Place the unit into the enclosure so the holes in the mechanism  
line up with the holes in the enclosure.  
7. Secure the unit into the enclosure using 4 thru bolts (1/4-20 or  
larger), 8 fender washers, and 4 Nyloc nuts (see Figure 10).  
Tighten securely.  
Figure 10. Secure Lift  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
INSTALL THE DISPLAY ON THE LIFT  
Attach Brackets to the Display  
1. Follow the instructions accompanying the PSB brackets  
designed for your display.  
Remove screws  
Mount the Display  
1. Remove 4 screws and slide back panel cover up and out (see  
Figure 11).  
2. Make sure the latch on the mount is lowered to the side before  
attempting to place the display on the mount (see Figure 12).  
3. With the aid of another person, lift the display up to the mount,  
aligning the PSB mounting buttons on the display with the  
teardrop slots on the mount, and set the plasma into place.  
Figure 11. Back Panel Cover Removal  
CAUTION: If the latch does not travel to the full upright position,  
remove and reset the display.  
Latch Lowered  
4. While supporting the display, raise the latch.  
5. Install Q-clamp (see Figure 13).  
Raise Latch to Secure Display  
6. Install back panel cover and secure using 4 screws.  
Tear Drop Slots  
Figure 12. Latch and Tear Drop Slots  
Q-clamp  
Figure 13. Install Q-clamp  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
ADJUSTMENTS  
WARNING: Be aware during the  
installation that this is a motorized  
device, and there are pinch points for  
people and for electrical wiring.  
Width Adjustment  
Eight 1/4-20 Socket  
Head AllenScrews  
Adjust width as follows (see Figure 14):  
1. Loosen the six 5/16”-18X5/8” hex head bolts on the front of  
each half of the motor/control box and eight 1/4-20 socket head  
Allen screws (4 front and 4 back) on the bracket mounting  
crossbrace.  
Bracket Mounting Crossbrace  
Motor/Control Box  
Six Hex Head Bolts  
2. Slide the halves of the lift to the disired width and secure by  
tightening the bolts and socket head Allen screws loosened in  
Step 1.  
Figure 14. Width Adjustmentr  
Adjust Vertical Travel  
WARNING: Be aware during the  
installation that this is a motorized  
device, and there are pinch points for  
people and for electrical wiring.  
CCW  
CW  
CAUTION: Vertical travel adjustment must always be made with  
the shelf in the middle of travel position and the power switch OFF.  
There are two knobs for setting the travel limits, which are located  
at one end of the base controller housing (see Figure 15). The knob  
closest to the outside is the down stop limit adjustment. The knob  
closest to the center is the up stop limit adjustment  
1. With the shelf in the middle of travel position and the power  
switch OFF, adjust the down limit to the desired height by turn-  
ing the down stop adjustment knob (clockwise = higher posi-  
tion, counterclockwise = lower position).  
CAUTION: The unit must always be able to reach its own limit  
switches and turn itself off.  
2. Check to be sure the limit switch stops the unit and the unit is  
not being stopped due to interference.  
Figure 15. Vertical Travel Adjustment  
3. With the shelf in the middle of travel position and the power  
switch OFF, adjust the up limit to the desired height by turning  
the down stop adjustment knob (clockwise = higher position,  
counterclockwise = lower position)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
THIS PAGE INTENTIONALLY BLANK  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
WIRING EXAMPLES  
The information on the following pages cover the most common wiring options:  
Pushbutton  
Extend and Retract Terminals to be Triggered By  
Separate Dry Contacts  
Remote (RC-10)  
12 Volt out supply  
24 Volt out supply  
Two dry contact closures  
Voltage Sensing  
Figure 16. 12 Volt Supply Jumper  
Pushbutton  
Wire for pushbutton operation as follows:  
1. Install a wire between terminal 5 (extend/retract common) and  
ground terminal 3 (see Figure 16).  
2. Connect one wire from pushbutton to terminal #4  
(12 VDC power supply) and the other wire from the pushbut-  
ton to terminal #6 (extend/retract) (see Figure 17).  
Figure 17. Pushbutton Wires  
With the unit plugged in, push the button once and the unit should  
extend. Push the button during travel and the unit will stop at that  
location. Push the button after the unit is extended or stopped in  
mid-travel and the unit will retract.  
Common  
Extend and Retract Terminals to be Triggered By  
Separate Dry Contacts  
These terminals can be used with a wall switch or a separate set of  
dry contacts for dedicated extend and dedicated retract. Momentary  
contacts are preferable.  
Figure 18. Common for Extend and Retract Contacts  
NOTE: The connection between the ground (#13) and any other  
terminal connection must be broken (open) before completing the  
next circuit.  
Extend  
1. Connect the common to terminal #13 (see Figure 18).  
2. Connect the extend to terminal #11 (see Figure 19).  
3. Connect the retract to terminal #12 (see Figure 20).  
Figure 19. Extend Contact Wiring  
Completing the circuit between terminal #13 and terminal #11 will  
cause the unit to extend to the show position (see “Adjust Vertical  
Travel” on page 11 to change height setting). Completing the cir-  
cuit between terminal #13 and terminal #12 will cause the unit to  
retract to the closed position.  
Retract  
Figure 20. Retract Contact Wiring  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
THIS PAGE INTENTIONALLY BLANK  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
Remote (RC-10)  
RC-10 Controller  
Circuit Board Box Assembly  
RC-10 Remote  
Figure 21. Contacts Connection  
Wire for remote (RC-10) operation as follows (see Figure 21):  
1. Install a jumper wire between terminals #6 and  
terminal #2 (see Figure 22).  
2. Connect the white wire of the RC-10 controller unit to  
terminal #1 (see Figure 23).  
3. Connect the red wire of the RC-10 controller unit to  
terminal #2.  
Figure 22. Contacts Connection  
4. Connect the black wire of the RC-10 controller unit to  
terminal #5.  
Black lead  
Red lead  
5. Connect the power source to the lift.  
NOTE: If the unit does not activate, check to make sure the 9 volt  
battery is working and make sure the dip switches in the send-  
ing unit match the dip switch settings in the controller unit (see  
Figure 24).  
Figure 23. Contacts Connection  
Figure 24. Dip Switches  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
THIS PAGE INTENTIONALLY BLANK  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
12 Volt Out Supply  
This internal power supply can be used to power external  
devices &/or to initiate specific functions (see Pushbutton  
operation and Figure 25).  
1. Connect one lead to 12 VOLT GROUND (terminal #9).  
2. Connect one lead to 12 VOLTS OUT (terminal #10).  
24 Volt Out Supply  
Figure 25. 12 Volts  
This internal power supply can be used to power external  
devices & remote controllers (see Figure 26).  
1. Connect one lead to 24 VOLT COMMON (terminal #2).  
2. Connect one lead to 24 VOLTS OUT (terminal #1).  
Two Dry Contact Closures  
NOTE: Dry contacts are rated for 1 Amp @ 24 volts.  
Figure 24. 26 Volts  
These contacts can be used to complete circuits to external  
devices (see Figure 27 and Figure 28).  
1. Connect one lead to terminal #17 (extend limit common).  
2. Connect one lead to terminal #16 (closes when unit  
reaches full extension).  
3. Connect one lead to terminal #19 (retract limit common).  
Figure 27. Extend Dry Contacts  
4. Connect one lead to terminal #18 (closes when unit is  
fully retracted).  
Low Voltage Sensing  
1. Connect positive lead (5 - 30 volts AC/DC) to terminal #7  
and ground of switching device to terminal #8 (see  
Figure 29). Unit extends when voltage is sensed, retracts  
when voltage ceases.  
Figure 28. Retract Dry Contacts  
Example using internal 12 volt DC supply (Figure 30):  
1 2 3 4 5 6 7 8  
Figure 29. Low Voltage Sensing  
Figure 30. 12 Volt DC Supply  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
THIS PAGE INTENTIONALLY BLANK  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
TROUBLESHOOTING  
If the lift is installed according to these instructions, it should operate trouble-free indefinitely. If you do encounter a problem, and  
it isn’t covered by the troubleshooting suggestions below, call the Technical Services Department at Chief Manufacturing:  
1-800-582-6480  
952-894-6280  
Possible  
Symptom(s)  
No Movement and No  
Causes  
No Power  
Suggested Action  
1. Check power to unit (supply, cord, activation  
Sound  
control, and connections).  
No power: Provide power, repair cord, tighten  
connections or repair activation control.  
Power:  
Check fuse on circuit board. If fuse is OK,  
proceed to next step.  
Faulty Circuit Board  
2. Check circuit board as follows:  
Make three jumper wires with ends stripped.  
Install one jumper wire on terminal 11.  
Install one jumper wire on terminal 12.  
Install one jumper wire on terminal 13.  
Momentarily touch jumper wire from terminal 11 to  
terminal 13. Unit should extend.  
Momentarily touch jumper wire from terminal 12 to  
terminal 13. Unit should retract.  
Activates  
In both  
Directions: Circuit board OK, faulty activation  
interface. Check remote switch, circuit, or  
batteries in remote control.  
Unit  
Fails  
Both/Either  
Direction: Call Chief Manufacturing.  
Unit Operates Noisily  
(Squeeling or grinding)  
Track Misalignment  
1. Check for noise and/or metal shavings in track  
Noise or  
Shavings: Check and adjust track and/or shelf as  
necessary.  
No Track  
Noise:  
Possible brake problem, call Chief  
Manufacturing  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
TERMINAL FUNCTION DEFINITIONS  
TERMINAL  
NUMBER  
FUNCTION  
DESCRIPTION  
WIRING OPTIONS  
NOTES  
This is an internal power supply for  
powering external devices & Remote  
Controllers.  
24 VOLT AC  
24 volt AC output  
1
2
Chief Mfg. offers the RC-10 Radio  
Frequency Remote Controller which runs  
off of this power supply.  
24 VOLT AC  
COMMON  
24 volt AC common  
GROUND  
Ground  
This is an internal power supply for  
powering external devices &/or used for  
initiating specific functions  
3
4
(Extend/Retract 5 or Voltage Sensor 7).  
12 VOLT DC  
12 volt DC  
Initiates movement if lift is static, or To Operate using Internal Power  
Function operates on momentary switch  
only.  
EXTEND/  
RETRACT  
stops movement if lift is in motion.  
Direction of travel will be opposite  
of last direction of travel.  
Source  
5
6
Connect terminals 3 & 6 with  
Jumper Wire. Connect  
Momentary Switch to terminal 4.  
Connect other line of Momentary  
Switch to terminal 5.  
Operating range is 5 – 30 Volts AC or DC  
Used in conjunction with  
Extend/Retract when using an  
external power source to initiate  
movement.  
EXTEND/  
RETRACT  
COMMON  
To Operate using External Power  
Source  
Connect External Power Supply’s EXTEND/RETRACT TERMINAL 5.  
Common to terminal 6. Connect  
NOT TO BE USED AS GROUND FOR  
FUNCTION OTHER THAN  
initiating signal to terminal 5.  
When terminal senses voltage, unit  
will extend.  
Voltage Sensing  
Connect positive lead to terminal  
7. Connect Ground of switching  
device to terminal 8.  
VOLTAGE  
SENSOR  
Operating range is 5 – 30 Volts AC or DC  
7
8
When terminal senses cessation of  
voltage, unit will retract.  
Single-Pull/Throw Latching  
Switch  
Connect terminals 3 & 8 with  
Jumper Wire. Connect first  
Switch Terminal to terminal 4.  
NOT TO BE USED AS GROUND FOR  
FUNCTION OTHER THAN VOLTAGE  
SENSOR TERMINAL 7.  
VOLTAGE  
SENSOR  
COMMON  
Used in conjunction with Voltage  
Sensor when using an external  
power source to initiate movement. Connect other Switch Terminal to  
terminal 7.  
Extends unit to maximum limit,  
Feature not available on all models.  
bypassing normal-use travel setting.  
SERVICE  
EXTEND  
Momentary or Latching contact to  
If using Latching Switch, be sure to  
disengage Switch prior to initiating any  
other function.  
9
Ground terminals 3, 10, 13, or 20.  
Often used for servicing projectors  
in ceiling lifts on PCL and MD  
models  
GROUND  
Ground  
10  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual  
Plasma Display Electric Pop-Up Lift  
Extends unit to preset travel limit.  
If using Latching Switch, be sure to  
disengage Switch prior to initiating any  
other function.  
EXTEND  
11  
12  
Customer within a preset maximum  
range may adjust travel limits.  
Momentary or Latching contact to  
Ground terminals 3, 10, 13, or 20.  
Retracts unit to preset travel limit.  
If using Latching Switch, be sure to  
disengage Switch prior to initiating any  
other function.  
RETRACT  
GROUND  
Travel limits may be adjusted by  
customer within a preset maximum  
range.  
Ground  
13  
14  
Immediately reverses direction of  
travel when triggered while unit is  
extending.  
Chief Mfg. offers the SS-10 Pressure  
Sensitive Safety Strip to provide this  
function.  
Please specify how many inches required  
spanning entire pinch zone.  
The SS-10 must be ordered with the ST-15  
Terminals.  
EXTEND  
ERROR  
Momentary contact to Ground  
terminals 3, 10, 13, or 20.  
Immediately reverses direction of  
travel when triggered while unit is  
retracting.  
RETRACT  
ERROR  
15  
16  
EXTEND  
LIMIT  
RELAY  
Closes set of internal dry contacts  
when unit reaches full extension.  
RATED FOR 1 AMP @ 24 VOLTS  
EXTEND  
LIMIT  
17  
18  
RELAY  
COMMON  
RETRACT  
LIMIT  
RELAY  
Closes set of internal dry contacts  
when unit reaches full retraction.  
RATED FOR 1 AMP @ 24 VOLTS  
RETRACT  
LIMIT  
19  
20  
RELAY  
COMMON  
GROUND  
Ground  
WIRING THE RC-10  
Connect white lead to terminal 1, red lead to terminal 2, and black lead to terminal 5.  
Place jumper wire fromterminal 2 to terminal 6  
WIRING A MOMENTARY PUSH BUTTON  
Connect terminals 3 & 6 with Jumper Wire. Connect Momentary Switch to terminal  
4. Connect other line of Momentary Switch to terminal 5.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Server 26589 User Manual
Bogen Stereo Amplifier C10MOH User Manual
Bogen Stereo System LUAMFMT User Manual
Boss Audio Systems Car Amplifier BV9997BI User Manual
Braun Electric Shaver 350CC 4 User Manual
Bush Hog Compact Loader FC 0014 User Manual
Canon Camera Accessories PB E2 User Manual
Canon Scanner CR 180 User Manual
Channel Vision Camera Accessories B 201 User Manual
Chef Pepin Fryer CH48275 User Manual