ꢀA/C-HEATER SYSTEM - MANUAL
ꢀ2001 Chevrolet Camaro
2000-01 MANUAL A/C-HEATER SYSTEMS
General Motors
Chevrolet; Camaro
Pontiac; Firebird
* PLEASE READ THIS FIRST *
WARNING: To avoid injury from accidental air bag deployment, read and
carefully follow all SERVICE PRECAUTIONS and DISABLING &
ACTIVATING AIR BAG SYSTEM procedures in AIR BAG RESTRAINT
SYSTEM article in ACCESSORIES/SAFETY EQUIPMENT section.
SPECIFICATIONS
SPECIFICATIONS
Application
Specification
Compressor Type ................................. Harrison V7 7-Cyl.
System Oil Capacity (1) ..................................... 9 ozs.
Refrigerant (R-134a) Capacity ............................ 24.0 ozs.
System Operating Pressures (2)
2000 Models
High Side ........................ 115-200 psi (8.1-14.1 kg/cm )
Low Side ............................ 25-37 psi (1.8-2.6 kg/cm )
2001 Models
High Side ....................... 202-244 psi (14.2-17.2 kg/cm )
Low Side ............................ 40-44 psi (2.8-3.1 kg/cm )
(1) - Use PAG Refrigerant Oil (Part No. 12345923).
(2) - Measured at ambient temperature of 70-80 F (21-27 C),
with more than 50 percent relative humidity.
DESCRIPTION
The manual A/C-heater system delivers heated or cooled and
dehumidified air. Air distribution is controlled through a manual A/C-
heater control panel and vacuum-operated doors.
OPERATION
A/C-HEATER CONTROL PANEL
Several mode settings are available on the A/C-heater control
panel to allow selection of a desirable comfort level. See Fig. 1. The
available settings are as follows:
OFF
No blower and A/C operation in this position. With vehicle
moving forward, a slight amount of air will enter passenger
compartment.
MAX
Maximum cooling is provided in this setting. Conditioned air
is distributed through dash registers. This is the only mode in which
Download from Www.Somanuals.com. All Manuals Search And Download.
1) Remove right instrument panel sound insulator. Remove
temperature control cable from heater housing. Move temperature
control knob from full cold to full hot setting. If cable binds or
pulley does not rotate freely, replace cable. Set temperature control
knob to detent position halfway between full cold and full hot
setting.
2) If control cable pulley is offset by 5-10 degrees toward
full cold side, no adjustment is necessary. See Fig. 2. If control
cable pulley is offset toward full hot side, remove spring from
control cable pulley. Rotate pulley 5-10 degrees toward full cold.
Install control cable pulley spring. Install temperature control cable
to heater housing.
Fig. 2: Adjusting Temperature Control Cable
Courtesy of General Motors Corp.
TROUBLE SHOOTING
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE:
For additional trouble shooting information, see MANUAL
A/C-HEATER SYSTEMS - TROUBLE SHOOTING article.
BLOWER MOTOR
1) If blower does not operate, check HVAC fuse (20-amp) in
instrument panel fuse block. If fuse is blown, check for short to
ground in Brown wire between HVAC fuse (20-amp) and mode selector
switch 3-pin connector terminal "C". If fuse is okay, check I/P-1 fuse
(40-amp) in underhood electrical center. If fuse is blown, check for
short to ground in Red wire between I/P-1 fuse (40-amp) and blower
motor relay harness connector terminal A2.
2) Ensure ground connectors located near left or right "A"
pillar, bolted to instrument panel mounting stud behind kick panel are
clean and tight. Check for a broken or partially broken wire inside of
insulation which could cause system malfunction but prove good in a
continuity/voltage check with system disconnected. Check for proper
installation of aftermarket electronic equipment.
SYSTEM TESTS
WARNING: To avoid injury from accidental air bag deployment, read and
carefully follow all SERVICE PRECAUTIONS and DISABLING &
ACTIVATING AIR BAG SYSTEM procedures in AIR BAG SYSTEM SAFETY
article in GENERAL SERVICING.
A/C SYSTEM PERFORMANCE
1) Rotate temperature control knob from full cold to full hot
and back to full cold. Listen for temperature valve to seat in both
full hot and full cold position. If temperature valve seats in both
positions, go to next step. If temperature valve does not seat in both
positions, go to step 4).
2) Park vehicle out of direct sunlight. Close doors and
windows. Open driver’s window 5-6" (127-152 mm). Open engine hood.
Place vehicle in Park (A/T) or Neutral (M/T), and set parking brake.
Set temperature control to maximum cold, maximum A/C, and blower to
high speed. Start engine and go to next step.
3) Observe A/C compressor. If compressor engages, go to next
step. If compressor does not engage, see A/C COMPRESSOR CLUTCH
CONTROLS - ALL MODELS article.
4) Check cooling fan operation. If both cooling fans are
operating, go to next step. If both cooling fans are not operating,
see ELECTRIC COOLING FANS - ALL MODELS article.
5) Connect A/C manifold gauge set. Place thermometer at
instrument panel center vent. Set temperature control to maximum cold,
maximum A/C, and blower to high speed. Run engine at idle for 2
minutes. Note high-side and low-side pressures on A/C manifold gauge
set. Determine relative humidity and ambient air temperature.
Ensure system is operating within specified range. See
A/C SYSTEM PERFORMANCE PRESSURE SPECIFICATIONS (2000 MODELS) and
A/C SYSTEM PERFORMANCE TEMPERATURE SPECIFICATIONS (2000 MODELS)
tables. Also see
A/C SYSTEM PERFORMANCE PRESSURE SPECIFICATIONS (2001 MODELS) and
A/C SYSTEM PERFORMANCE TEMPERATURE SPECIFICATIONS (2001 MODELS).
6) If system is operating within specified range, system is
okay. If system is not operating within specified range, check
Variable Displacement Orifice Tube (VDOT) system. See MANUAL A/C-
HEATER SYSTEMS - TROUBLE SHOOTING article.
A/C SYSTEM PERFORMANCE PRESSURE SPECIFICATIONS (2000 MODELS)
Download from Www.Somanuals.com. All Manuals Search And Download.
Ambient Temp.
F ( C)
High Pressure
psi (kg/cm )
Low Pressure
psi (kg/cm )
70-80 (21-29) (1) ...... 115-190 (8.1-13.4) ........ 24-34 (1.7-2.4)
70-80 (21-29) (2) ...... 115-200 (8.1-14.1) ........ 25-37 (1.8-2.6)
80-90 (27-33) (1) ...... 140-215 (9.8-15.1) ........ 28-38 (2.0-2.7)
80-90 (27-33) (2) ..... 150-235 (10.5-16.5) ....... 30-40 (2.1-2.8)
90-100 (33-38) (3) .... 165-260 (11.6-18.2) ....... 34-43 (2.4-3.0)
90-100 (33-38) (4) .... 185-270 (13.0-19.0) ....... 36-48 (2.5-3.4)
100-110 (38-44) (5) ... 210-290 (14.8-20.4) ....... 40-49 (2.8-3.4)
100-110 (38-44) (6) ... 220-310 (15.5-21.8) ....... 43-52 (3.0-3.7)
(1) - With relative humidity at less than 50 percent.
(2) - With relative humidity at more than 50 percent.
(3) - With relative humidity at less than 40 percent.
(4) - With relative humidity at more than 40 percent.
(5) - With relative humidity at less than 20 percent.
(6) - With relative humidity at more than 20 percent.
A/C SYSTEM PERFORMANCE TEMPERATURE SPECIFICATIONS (2000 MODELS)
Ambient Temp. F ( C)
Center Vent Temp. F ( C)
70-80 (21-27) (1) ...................................... 38-48 (3-9)
70-80 (21-27) (2) ..................................... 40-55 (4-13)
80-90 (27-33) (1) ..................................... 38-55 (3-13)
80-90 (27-33) (2) ..................................... 45-65 (7-18)
90-100 (33-38) (3) .................................... 45-63 (7-17)
90-100 (33-38) (4) ................................... 55-68 (13-20)
100-110 (38-44) (5) .................................. 53-64 (12-18)
100-110 (38-44) (6) .................................. 58-70 (14-21)
(1) - With relative humidity at less than 50 percent.
(2) - With relative humidity at more than 50 percent.
(3) - With relative humidity at less than 40 percent.
(4) - With relative humidity at more than 40 percent.
(5) - With relative humidity at less than 20 percent.
(6) - With relative humidity at more than 20 percent.
A/C SYSTEM PERFORMANCE PRESSURE SPECIFICATIONS (2001 MODELS)
Ambient Temp.
F ( C)
High Pressure
psi (kg/cm)
Low Pressure
psi (kg/cm)
50-55 (13-18) (1) ..... 157-187 (11.0-13.1) ....... 32-37 (2.2-2.6)
66-75 (19-24) (2) ..... 177-218 (12.4-15.3) ....... 36-41 (2.5-2.9)
76-85 (25-29) (3) ..... 202-244 (14.2-17.2) ....... 40-44 (2.8-3.1)
86-95 (30-35) (4) ..... 218-261 (15.3-18.4) ....... 42-46 (3.0-3.2)
96-105 (36-41) (6) .... 245-293 (17.2-20.6) ....... 46-51 (3.2-3.6)
106-115 (42-46) (5) ... 255-300 (17.9-21.0) ....... 48-53 (3.4-3.7)
116-120 (47-49) (7) ... 273-303 (19.2-21.3) ....... 49-54 (3.4-3.8)
(1) - With relative humidity at 0-50 percent.
(2) - With relative humidity at more than 40 percent.
(3) - With relative humidity at more than 60 percent.
(4) - With relative humidity at more than 30 percent.
(5) - With relative humidity at more than 40 percent.
(6) - With relative humidity at more than 20 percent.
(7) - With relative humidity at less than 30 percent.
Download from Www.Somanuals.com. All Manuals Search And Download.
A/C SYSTEM PERFORMANCE TEMPERATURE SPECIFICATIONS (2001 MODELS)
Ambient Temp. F ( C)
Center Vent Temp. F ( C)
70-80 (21-27) (1) ...................................... 38-48 (3-9)
70-80 (21-27) (2) ..................................... 40-55 (4-13)
80-90 (27-33) (1) ..................................... 38-55 (3-13)
80-90 (27-33) (2) ..................................... 45-65 (7-18)
90-100 (33-38) (3) .................................... 45-63 (7-17)
90-100 (33-38) (4) ................................... 55-68 (13-20)
100-110 (38-44) (5) .................................. 53-64 (12-18)
100-110 (38-44) (6) .................................. 58-70 (14-21)
(1) - With relative humidity at less than 50 percent.
(2) - With relative humidity at more than 50 percent.
(3) - With relative humidity at less than 40 percent.
(4) - With relative humidity at more than 40 percent.
(5) - With relative humidity at less than 20 percent.
(6) - With relative humidity at more than 20 percent.
DIAGNOSTIC SYSTEM TEST
1) Connect scan tool to Data Link Connector (DLC). DLC is
located under instrument panel, near steering column. If scan tool
powers up, go to next step. If scan tool does not power up, go to
appropriate BODY CONTROL MODULES article in ACCESSORIES & EQUIPMENT.
2) Turn ignition switch to ON position. Attempt to establish
communications with A/C-heater control module, Body Control Module
(BCM) and Powertrain Control Module (PCM). If communications is
establish to all desired modules, go to next step. If communications
is not established to all desired modules, go to appropriate BODY
CONTROL MODULES article in ACCESSORIES & EQUIPMENT.
3) Following scan tool manufacturer’s instructions, select
DISPLAY DTCs function for A/C-heater control module, BCM and PCM. If
any Diagnostic Trouble Codes (DTCs) are displayed, go to next step. If
no DTCs are displayed, perform procedure for appropriate symptom.
4) If scan tool displays any DTCs beginning with "U", go to
appropriate BODY CONTROL MODULES article in ACCESSORIES & EQUIPMENT.
If no DTCs beginning with "U" are displayed, go to next step.
5) If scan tool displays any DTCs beginning with "B", go to
appropriate BODY CONTROL MODULES article in ACCESSORIES & EQUIPMENT.
If no DTCs beginning with "B" are displayed, go to next step.
6) If scan tool displays any DTCs beginning with "P", go to
appropriate SELF-DIAGNOSTICS article in ENGINE PERFORMANCE. If no DTCs
beginning with "P" are displayed, perform procedure for appropriate
symptom.
BLOWER MOTOR ALWAYS ON
2000 Models
1) Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2) Turn ignition switch to OFF position. Disconnect blower
motor relay. Using test light connected to ground, probe blower motor
relay harness connector terminal A1 (Orange wire). If test light
illuminates, go to next step. If test light does not illuminate, go to
step 4).
3) Repair short to battery voltage in Orange wire between
blower motor relay harness connector terminal A1 and blower motor
switch harness connector C1 terminal "B" located at A/C-heater control
panel. After repair, go to step 9).
4) Using test light connected to ground, probe blower motor
Download from Www.Somanuals.com. All Manuals Search And Download.
relay harness connector terminal B2 (Dark Blue wire). If test light
illuminates, go to next step. If test light does not illuminate, go to
step 6).
5) Repair short to battery voltage in Dark Blue wire between
blower motor relay harness connector terminal B2 and blower motor
resistor harness connector terminal "C". After repair, go to step 9).
6) Using test light connected to ground, probe blower motor
relay harness connector terminal C1 (Purple wire). If test light
illuminates, go to next step. If test light does not illuminate, go to
step 8).
7) Repair short to battery voltage in Purple wire between
blower motor relay harness connector terminal C1 and blower motor
harness connector terminal "B". After repair, go to step 9).
8) Replace blower motor relay. After repair, go to next step.
9) Operate blower system to verify repair. If blower motor
operates normally, repair is complete. If blower motor is still
inoperative, return to step 2).
2001 Models
1) Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2) Turn ignition switch to ON position. Set mode switch in
OFF position. If blower motor is off, problem is intermittent. Check
for faulty wiring or poor connections. Repair or replace as necessary.
After repair, go to step 14). If no problem is found, go to next step.
3) Turn ignition switch to OFF position. Disconnect blower
motor relay. Turn ignition switch to ON position. If blower motor does
not operate, go to next step. If blower motor operates, go to 11).
4) Ensure mode switch is in OFF position. Set blower speed
switch at lowest speed position. Using test light connected to ground,
probe blower motor relay harness connector terminal B2. If test light
illuminates, go to next step. If test light does not illuminate, go to
step 6).
5) Check Orange wire between blower motor switch harness
connector C1 terminal "B" and blower motor relay harness connector
terminal B2 for short to voltage. Repair Orange wire as necessary.
After repair, go to step 14). If wire is okay, go to step 10).
6) Using test light connected to ground, probe blower motor
relay harness connector terminal B2 (Dark Blue wire). If test light
illuminates, go to next step. If test light does not illuminate, go to
step 9).
7) Check Dark Blue wire between blower motor relay harness
connector terminal B2 and blower motor resistor harness connector
terminal "C" for short to voltage. Repair Dark Blue wire as necessary.
After repair, go to step 14). If wire is okay, go to next step.
8) Check Yellow, Tan and Light Blue wires for short to
voltage between blower motor switch harness connector C1 at A/C-heater
control panel and blower motor resistor harness connector. Repair
suspect wire as necessary. After repair, go to step 14). If wires are
okay, go to step 10).
9) Check for poor connections or connector damage at blower
motor relay harness connectors. Repair or replace as necessary. After
repair, go to step 14). If connections are okay, go to step 12).
10) Check for poor connections or connector damage at A/C-
heater control panel harness connectors. Repair or replace as
necessary. After repair, go to step 14). If connections are okay, go
to step 13).
11) Repair short to voltage in Purple wire between blower
motor harness connector terminal "B" and blower motor relay harness
connector terminal C1. After repair, go to step 14).
12) Replace blower motor relay. After repair, go to step 14).
13) Replace A/C-heater control panel. See
A/C-HEATER CONTROL PANEL under REMOVAL & INSTALLATION. After repair,
go to next step.
Download from Www.Somanuals.com. All Manuals Search And Download.
14) Operate blower system to verify repair. If blower motor
operates normally, repair is complete. If blower motor is still
inoperative, return to step 2).
BLOWER MOTOR INOPERATIVE IN HIGH SPEED
2000 Models
1) Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2) Set mode switch in VENT position. Set blower motor switch
in highest speed position. Using test light connected to ground,
backprobe A/C-heater control panel harness connector C1 terminal "B"
(Orange wire). If test light illuminates, go to next step. If test
light does not illuminate, go to step 4).
3) Using test light connected to ground, probe blower motor
relay harness connector terminal A1 (Orange wire). If test light
illuminates, go to step 6). If test light does not illuminate, go to
step 7).
4) Check for poor connection or connector damage at A/C-
heater control panel harness connector C1. See WIRING DIAGRAMS. Repair
or replace as necessary. After repair, go to step 13). If connections
are okay, go to next step.
5) Replace blower motor switch. See BLOWER MOTOR SWITCH under
REMOVAL & INSTALLATION. After repair, go to step 13).
6) Connect test light between blower motor relay harness
connector terminals A1 (Orange wire) and C2 (Black wire). If test
light illuminates, go to step 8). If test light does not illuminate,
go to step 9).
7) Repair open or poor connection in Orange wire between
blower motor relay harness connector terminal A1 and blower motor
resistor harness connector terminal "C". After repair, go to step 13).
8) Connect test light between blower motor relay harness
connector terminals A2 (Red wire) and C2 (Black wire). If test light
illuminates, go to step 10). If test light does not illuminate, go to
step 12).
9) Repair open or poor connection in Black wire between
blower motor relay harness connector terminal C2 and ground. After
repair, go to step 13).
10) Check for poor connections or connector damage at blower
motor relay harness connector. Repair or replace as necessary. After
repair, go to step 13). If connections are okay, go to next step.
11) Replace blower motor relay. After repair, go to step 13).
12) Repair open or poor connection in Red wire between blower
motor relay harness connector terminal A2 and I/P MAXI-FUSE No. 1
located in underhood electrical center. After repair, go to next step.
13) Operate blower system to verify repair. If blower motor
operates normally, repair is complete. If blower motor is still
inoperative in high speed, return to step 3).
BLOWER MOTOR INOPERATIVE
2000 Models
1) Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2) Turn ignition switch to ON position. Set mode selector
switch to VENT position. Using test light connected to ground, probe
A/C-heater control panel harness connector C1 terminal "E" (Light
Green wire). If test light illuminates, go to next step. If test light
does not illuminate, go to step 15).
3) Set blower motor switch in low speed position. Using test
light connected to ground, probe A/C-heater control panel harness
connector C1 terminal "A" (Yellow wire). If test light illuminates, go
to next step. If test light does not illuminate, go to step 5).
4) Turn ignition switch to OFF position. Disconnect blower
motor relay. Connect fused jumper wire between blower motor relay
Download from Www.Somanuals.com. All Manuals Search And Download.
harness connector terminal B2 (Dark Blue wire) and C1 (Purple wire).
Turn ignition switch to ON position. Set mode selector switch to VENT
position. Place blower motor switch in low speed position. If blower
motor operates, go to step 8). If blower motor does not operate, go to
step 7).
5) Check for poor connection or connector damage at blower
switch harness connector. Repair or replace as necessary. After
repair, go to step 20). If connection is okay, go to next step.
6) Replace blower motor switch. See BLOWER MOTOR SWITCH under
REMOVAL & INSTALLATION. After repair, go to step 20).
7) Leave jumper wire connected as described in step 4). Turn
ignition switch to OFF position. Disconnect blower motor harness
connector. Turn ignition switch to ON position. Connect test light
between blower motor harness connector terminals "A" (Black wire) and
"B" (Purple wire). If test light illuminates, go to step 11). If test
light does not illuminate, go to step 10).
8) Check for poor connection at blower motor relay harness
connector. Repair or replace as necessary. After repair, go to step
20). If connection is okay, go to next step.
9) Replace blower motor relay. After repair, go to step 20).
10) Leave jumper wire connected. Using test light connected
to ground, probe blower motor harness connector terminal "B" (Purple
wire). If test light illuminates, go to step 14). If test light does
not illuminate, go to step 13).
11) Check for poor connection or connector damage at blower
motor harness connector. Repair or replace as necessary. After repair,
go to step 20). If connection is okay, go to next step.
12) Replace blower motor. See BLOWER MOTOR under REMOVAL &
INSTALLATION. After repair, go to step 20).
13) Repair open or poor connection in Purple wire between
blower motor relay harness connector terminal C1 and blower motor
harness connector terminal "B". After repair, go to step 20).
14) Repair open or poor connection in Black wire between
ground and blower motor harness connector terminal "A". After repair,
go to step 20).
15) Using test light connected to ground, probe A/C-heater
control panel harness connector C2 terminal "C" (Brown wire). If test
light illuminates, go to next step. If test light does not illuminate,
go to step 19).
16) Check for open circuit or poor connection between A/C-
heater control panel harness connector C2 terminals "B" (Light Green
wire) and "C" (Brown wire). See WIRING DIAGRAMS. Repair or replace as
necessary. After repair, go to step 20). If no problem is found, go to
next step.
17) Check for poor connection(s) or connector damage at A/C-
heater control panel switch harness connectors. Repair or replace as
necessary. After repair, go to step 20). If connections are okay, go
to next step.
18) Replace A/C-heater control panel. See
A/C-HEATER CONTROL PANEL under REMOVAL & INSTALLATION. After repair,
go to step 20).
19) Check for poor connection or wire damage in Brown wire
between A/C-heater control panel harness connector C2 terminal "C" and
HVAC fuse (20-amp) located in instrument panel fuse block. Repair or
replace as necessary. After repair, go to next step.
20) Operate blower system to verify repair. If blower motor
operates normally, repair is complete. If blower motor is still
inoperative, return to step 3).
2001 Models
1) Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2) Turn ignition switch to ON position. Set mode selector
switch to VENT position. Place blower motor switch in each speed
Download from Www.Somanuals.com. All Manuals Search And Download.
position. If blower operates in any position, problem is intermittent.
Check for poor connections. loose components or damaged wiring. Repair
or replace as necessary. After repair, go to step 16). If blower motor
does not operate in any speed position, go to next step.
3) Turn ignition switch to OFF position. Disconnect blower
motor harness connector. Turn ignition switch to ON position. Place
blower motor switch in lowest speed position. Using test light
connected to ground, probe blower motor harness connector terminal "B"
(Purple wire). If test light illuminates, go to next step. If test
light does not illuminate, go to step 5).
4) Check Black wire between blower motor harness connector
terminal "A" and ground for open or high resistance. See
WIRING DIAGRAMS. Repair Black wire as necessary. After repair, go to
step 16). If wire is okay, go to step 10).
5) Turn ignition switch to OFF position. Disconnect blower
motor resistor harness connector. Turn ignition switch to ON position.
Set blower motor switch to lowest speed position. Using test light
connected to ground, probe blower motor resistor harness connector
terminal "B" (Yellow wire). If test light does not illuminate, go to
next step. If test light illuminates, go to step 8).
6) Check Yellow wire between blower motor resistor harness
connector terminal "B" and A/C-heater control panel harness connector
C1 terminal "A" for open or high resistance. Repair Yellow wire as
necessary. After repair, go to step 16). If wire is okay, go to next
step.
7) Turn ignition switch to OFF position. Disconnect A/C-
heater control panel harness connector C2. See WIRING DIAGRAMS. Turn
ignition switch to ON position. Using test light connected to ground,
probe A/C-heater control panel harness connector C2 terminal "C"
(Brown wire). If test light illuminates, go to step 11). If test light
does not illuminate, go to step 12).
8) Check Purple wire between blower motor relay harness
connector terminal C1 and blower motor harness connector terminal "B"
for open or high resistance. Repair Purple wire as necessary. After
repair, go to step 16). If wire is okay, go to next step.
9) Check for poor connections or connector damage at blower
motor relay harness connector. Repair of replace as necessary. After
repair, go to step 16). If connections are okay, go to step 13).
10) Check for poor connections or connector damage at blower
motor harness connector. Repair of replace as necessary. After repair,
go to step 16). If connections are okay, go to step 14).
11) Check for poor connections or connector damage at A/C-
heater control panel harness connector. Repair of replace as
necessary. After repair, go to step 16). If connections are okay, go
to step 15).
12) Repair Brown wire between HVAC fuse (20-amp) located in
instrument panel fuse block and A/C-heater control panel harness
connector C2 terminal "C" as necessary. After repair, go to step 16).
13) Replace blower motor relay. After repair, go to step 16).
14) Replace blower motor. See BLOWER MOTOR under REMOVAL &
INSTALLATION. After repair, go to step 16).
15) Replace A/C-heater control panel. See
A/C-HEATER CONTROL PANEL under REMOVAL & INSTALLATION. After repair,
go to next step.
16) Operate blower system to verify repair. If blower motor
operates normally, repair is complete. If blower motor is still
inoperative, return to step 3).
BLOWER MOTOR OPERATES IN HIGH SPEED ONLY
2000 Models
1) Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2) Turn ignition switch to ON position. Set mode selector
Download from Www.Somanuals.com. All Manuals Search And Download.
switch in VENT position. Set blower motor switch in lowest speed
position. Using test light connected to ground, probe blower motor
resistor harness connector terminal "C" (Dark Blue wire). If test
light illuminates, go to next step. If test light does not illuminate,
go to step 4).
3) Using test light connected to ground, probe blower motor
relay harness connector terminal B2 (Dark Blue wire). If test light
illuminates, go to step 6). If test light does not illuminate, go to
step 8).
4) Check for poor connection or connector damage at blower
motor resistor harness connector. Repair or replace as necessary.
After repair, go to step 9). If connection is okay, go to next step.
5) Replace blower motor resistor. See BLOWER MOTOR RESISTOR
under REMOVAL & INSTALLATION. After repair, go to step 9).
6) Check for poor connection or connector damage at blower
motor relay harness connector. Repair or replace as necessary. After
repair, go to step 9). If connection is okay, go to next step.
7) Replace blower motor relay. After repair, go to step 9).
8) Repair open or poor connection in Dark Blue wire between
blower relay harness connector terminal B2 and blower motor resistor
harness connector terminal "C". After repair, go to next step.
9) Operate blower system to verify repair. If blower motor
operates normally, repair is complete. If blower motor is still
inoperative, return to step 3).
BLOWER SPEED INOPERATIVE IN LOW, MEDIUM-LOW OR MEDIUM-HIGH
SPEED
2000 Models
1) Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2) Turn ignition switch to OFF position. Disconnect blower
motor resistor harness connector. Turn ignition switch to ON position.
Set blower motor switch in OFF position. Using test light connected to
ground, probe A/C-heater control panel harness connector C1 terminal
for circuit corresponding to inoperative blower speed. See
WIRING DIAGRAMS. If test light illuminates on suspect circuit. go to
next step. If test light does not illuminate, go to step 5).
3) Check for poor connection or connector damage at blower
motor resistor harness connector. Repair or replace as necessary.
After repair, go to step 9). If connections are okay, go to next step.
4) Replace blower motor resistor. See BLOWER MOTOR RESISTOR
under REMOVAL & INSTALLATION. After repair, go to step 9).
5) Using test light connected to ground, individually probe
A/C-heater control panel harness connector C1 terminal which did not
cause test light to illuminate in step 2). If test light illuminates,
go to next step. If test light does not illuminate, go to step 7).
6) Repair open or poor connection in Yellow, Tan or Light
Blue wire(s) between A/C-heater control panel harness connector C1 and
blower motor resistor harness connector. See WIRING DIAGRAMS. After
repair, go to step 9).
7) Check for poor connections or connector damage at A/C-
heater control panel harness connector C1. Repair or replace as
necessary. After repair, go to step 9). If connections are okay, go to
next step.
8) Replace blower motor switch. See BLOWER MOTOR SWITCH under
REMOVAL & INSTALLATION. After repair, go to next step.
9) Operate blower system to verify repair. If blower motor
operates normally, repair is complete. If blower motor is still
inoperative, return to step 3).
BLOWER MOTOR MALFUNCTIONS
2001 Models
Download from Www.Somanuals.com. All Manuals Search And Download.
1) Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2) Turn ignition switch to ON position. Set mode switch to
VENT position. Turn blower switch to each speed position. If blower
motor operates normally, go to next step. If blower motor
malfunctions, go to step 4).
3) Place blower motor switch at maximum speed position. Place
mode switch in each position. If blower operates in each switch
position, problem is intermittent. Check for faulty wiring, poor
connections or damaged components. Repair as necessary. After repair,
go to step 24). If no problem is found, go to step 18).
4) Turn ignition switch to OFF position. Disconnect blower
motor harness connector. Turn ignition switch to ON position. Using
test light connected to ground, probe blower motor harness connector
terminal "B" (Purple wire). Place blower motor switch in each speed
position. If test light does not illuminate in each speed position, go
to next step. If test light illuminates in all speed positions, go to
step 16).
5) If test light does not illuminate in maximum speed
position, go to next step. If test light illuminates in maximum speed
position, go to step 10).
6) Turn ignition switch to OFF position. Disconnect blower
motor relay. Turn ignition switch to ON position. Using test light
connected to ground, probe blower motor relay harness connector
terminal A2 (Red wire). If test light illuminates, go to next step. If
test light does not illuminate, go to step 19).
7) Set blower motor switch in maximum speed position. Using
test light connected to ground, probe blower motor relay harness
connector terminal A1 (Orange wire). If test light does not
illuminate, go to next step. If test light illuminates, go to step 9).
8) Check Orange wire between blower motor relay harness
connector terminal A1 and blower motor switch harness connector C1
terminal "B" located at A/C-heater control panel for open or high
resistance. Repair Orange wire as necessary. After repair, go to step
24). If wire is okay, go to step 14).
9) Check Black wire for open or high resistance between
blower motor relay harness connector terminal C2 and ground. Repair
Black wire as necessary. After repair, go to step 24). If wire is
okay, go to step 15).
10) Turn ignition switch to OFF position. Disconnect blower
motor relay. Turn ignition switch to ON position. Using test light
connected to ground, probe blower motor relay harness connector
terminal B2 (Dark Blue wire). Alternately set blower motor switch in
minimum, M1 (medium-low) and M2 (medium-high) speed positions. If test
light illuminates in each speed position, go to step 15). If test
light does not illuminate, go to next step.
11) Check Dark Blue wire between blower motor relay harness
connector terminal B2 and blower motor resistor harness connector
terminal "C" for short to ground, open or high resistance. Repair Dark
Blue wire as necessary. After repair, go to step 24). If wire is okay,
go to next step.
12) Turn ignition switch to OFF position. Disconnect blower
motor resistor harness connector. Turn ignition switch to ON position.
Set mode switch in VENT position. Using test light connected to
ground, individually probe blower motor resistor harness connector
terminals "A" (Tan wire), "B" (Yellow wire) and "D" (Light Blue wire).
See WIRING DIAGRAMS. Set blower motor switch in speed position
corresponding to wire being tested. If test light does not illuminate
at any switch position, go to next step. If test light illuminates at
each switch position, go to step 17).
13) Check suspect blower motor control circuit identified in
previous step for open or high resistance. Repair suspect wire as
necessary. After repair, go to step 24). If wire is okay, go to step
18).
Download from Www.Somanuals.com. All Manuals Search And Download.
14) Check Light Green wire between A/C-heater control panel
harness connector C2 terminal "B" and blower motor switch harness
connector C1 terminal "E" located at A/C-heater control panel for open
or high resistance. Repair Light Green wire as necessary. After
repair, go to step 24). If wire is okay, go to step 18).
15) Check for poor connections or connector damage at blower
motor relay harness connector. Repair or replace as necessary. After
repair, go to step 24). If connections are okay, go to step 20).
16) Check for poor connections or connector damage at blower
motor harness connector. Repair or replace as necessary. After repair,
go to step 24). If connections are okay, go to step 21).
17) Check for poor connections or connector damage at blower
motor resistor harness connector. Repair or replace as necessary.
After repair, go to step 24). If connections are okay, go to step 22).
18) Check for poor connections or connector damage at A/C-
heater control panel harness connectors. Repair or replace as
necessary. After repair, go to step 24). If connections are okay, go
to step 23).
19) Repair Red wire between blower motor relay harness
connector terminal A2 and I/P-1 fuse (40-amp) located in underhood
fuse block. After repair, go to step 24).
20) Replace blower motor relay. After repair, go to step 24).
21) Replace blower motor. See BLOWER MOTOR under REMOVAL &
INSTALLATION. After repair, go to step 24).
22) Replace blower motor resistor. See BLOWER MOTOR RESISTOR
under REMOVAL & INSTALLATION. After repair, go to step 24).
23) Replace A/C-heater control panel. See
A/C-HEATER CONTROL PANEL under REMOVAL & INSTALLATION. After repair,
go to next step.
24) Operate blower system to verify repair. If blower motor
operates normally, repair is complete. If blower motor is still
inoperative, return to step 2).
REMOVAL & INSTALLATION
WARNING: To avoid injury from accidental air bag deployment, read and
carefully follow all SERVICE PRECAUTIONS and DISABLING &
ACTIVATING AIR BAG SYSTEM procedures in AIR BAG SYSTEM SAFETY
article in GENERAL SERVICING.
A/C COMPRESSOR
Removal (3.8L Engine)
1) Disconnect negative battery cable from engine block ground
stud. Discharge A/C system, using approved refrigerant
recovery/recycling equipment. Remove serpentine drive belt. Disconnect
electrical harness connector. Remove strap from compressor and
condenser hose assembly.
2) Raise and support vehicle. Remove compressor and condenser
hose bolt. Disconnect compressor and condenser hose assembly. Discard
"O" ring. Remove compressor bolts. Remove compressor and rear bracket
(if necessary).
Installation
1) To install, reverse removal procedure. If compressor is
being replaced, drain refrigerant oil from old compressor. Measure
amount of oil from old compressor. If measured amount is less than one
ounce, add 2 ounces to new compressor.
2) If more than one ounce is drained from old compressor, add
same amount to new compressor. Clean all fittings with mineral-base
refrigerant oil. Lightly coat all seals with mineral-base refrigerant
oil before assembling. Evacuate and charge A/C system.
Download from Www.Somanuals.com. All Manuals Search And Download.
Removal (5.7L Engine)
Disconnect negative battery cable. Discharge A/C system,
using approved refrigerant recovery/recycling equipment. Raise and
support vehicle. Remove serpentine drive belt and tensioner. Remove
compressor and condenser hose bolt. Disconnect compressor and
condenser hose assembly. Discard seal. Disconnect transmission oil
cooler pipes from engine bracket. Disconnect compressor electrical
connector. Remove compressor bolts. Remove compressor.
Installation
1) To install, reverse removal procedure. If compressor is
being replaced, drain refrigerant oil from old compressor. Measure
amount of oil from old compressor. If measured amount is less than one
ounce, add 2 ounces to new compressor.
2) If more than one ounce is drained from old compressor, add
same amount to new compressor. Clean all fittings with mineral-base
refrigerant oil. Lightly coat all seals with mineral-base refrigerant
oil before assembling. Evacuate and charge A/C system.
A/C-HEATER CONTROL PANEL
Removal & Installation
1) Disconnect negative battery cable. Remove center
instrument panel trim plate. Remove A/C-heater control panel retaining
bolts.
2) Pull A/C-heater control panel out from dash sufficiently
to disconnect wiring harness connectors, temperature control cable and
vacuum harness. Remove A/C-heater control panel. To install, reverse
removal procedure.
BLOWER MOTOR
Removal & Installation
Remove right side instrument panel insulator. Disconnect
blower motor harness connector. Remove blower motor retaining bolts.
Remove blower motor. To install, reverse removal procedure.
BLOWER MOTOR RESISTOR
Removal & Installation
Disconnect negative battery cable. Remove right instrument
panel insulator. Pull carpet away from A/C-heater case assembly.
Disconnect blower motor resistor electrical connector. Remove mounting
bolt from blower motor resistor. Remove blower motor resistor. To
install, reverse removal procedure.
BLOWER MOTOR SWITCH
Removal & Installation
Remove A/C-heater control panel. See A/C-HEATER CONTROL PANEL
. Pull off blower motor switch knob. Remove blower motor switch
retaining screw. Remove blower motor switch from A/C-heater control
panel. To install, reverse removal procedure.
CONDENSER
Removal & Installation
1) Disconnect negative battery cable. Discharge A/C system,
using approved refrigerant recovery/recycling equipment. Remove air
intake duct and air cleaner assembly. Remove upper radiator shroud
assembly.
Download from Www.Somanuals.com. All Manuals Search And Download.
2) Raise and support vehicle. Remove compressor and condenser
hose assembly fitting at condenser. Discard "O" ring. Lower vehicle.
Remove accumulator tube. Remove radiator air upper baffle from
condenser. Remove condenser.
3) To install, reverse removal procedure. Lightly coat "O"
rings with mineral-base refrigerant oil. Evacuate and charge A/C
system.
EVAPORATOR TUBE
Removal
Disconnect negative battery cable. Discharge A/C system,
using approved refrigerant recovery/recycling equipment. Disconnect
electrical connector at refrigerant pressure sensor. Remove strap from
evaporator tube. Remove accumulator tube. See ACCUMULATOR. Remove
evaporator tube fitting at accumulator and condenser. Remove
evaporator tube and discard "O" rings.
Installation
To install, reverse removal procedure. Clean all fittings
with mineral-base refrigerant oil. Lightly coat all seals with
mineral-base refrigerant oil before assembling. Evacuate and charge
A/C system.
EVAPORATOR
Removal
1) Disconnect negative battery cable. Discharge A/C system,
using approved refrigerant recovery/recycling equipment. Remove right
instrument panel sound insulator panel. Drain cooling system. Remove
heater hoses at heater core. Open glove box. Push sides of glove box
and remove glove box. Remove heater core. See HEATER CORE.
2) Remove temperature control cable at A/C-heater case.
Remove bolts, located in engine compartment, from A/C-heater case.
Slide A/C-heater case down to disengage upper case clip and A/C-heater
case.
3) Place a mat on passenger side floor to protect carpeting.
Using a small hand saw, remove perforated section of A/C-heater case
as one piece (DO NOT discard). Remove bolts and hoses retaining A/C
evaporator. Slide evaporator to left. Remove evaporator from A/C-
heater case. See Fig. 3.
Download from Www.Somanuals.com. All Manuals Search And Download.
Fig. 3: Exploded View Of A/C-Heater Assembly
Courtesy of General Motors Corp.
Installation
1) To install, reverse removal procedure. Transfer condensate
Download from Www.Somanuals.com. All Manuals Search And Download.
screen to new evaporator. Using appropriate adhesive, install NEW
evaporator core gasket in same position as original. Slide new
evaporator to right until full seated in A/C-heater case.
2) Apply sealer (not epoxy) between evaporator and evaporator
upper and lower case. Using epoxy, glue perforated section of heater
and A/C evaporator case to A/C-heater case. After epoxy dries, use
thumb to grade sealant on inside and outside to ensure a water-tight
seal.
3) Slide temperature valve case upward into position until
upper clip engages. Engage snap on left edge of A/C-heater case to
distribution case. Refill cooling system. Evacuate and charge A/C
system.
HEATER CORE
CAUTION: DO NOT use excessive force to remove heater hoses from heater
core pipes. Heater core can be damaged.
Removal
Drain cooling system. Remove heater hoses from heater core
pipes. Open glove box. Push sides of glove box and remove glove box.
Remove heater module bolts and cover. Remove heater core bolt, heater
core clamp and heater core.
Installation
To install, reverse removal procedure. Lubricate heater
pipes. Verify seal is installed correctly by observing seal from
inside engine compartment. If seal leaks, apply sealer between heater
core pipes and evaporator housing. Refill cooling system.
ACCUMULATOR
Removal
Disconnect negative battery cable. Discharge A/C system,
using approved refrigerant recovery/recycling equipment. Remove
accumulator tube fitting at accumulator. Remove accumulator tube, and
discard "O" ring. Remove evaporator tube fitting at accumulator.
Remove accumulator from bracket, and discard "O" ring.
Installation
1) If accumulator is being replaced, drain and measure amount
of refrigerant oil in old accumulator. Add drained amount plus one
fluid ounce of new refrigerant oil to new accumulator.
2) Clean all fittings with mineral-base refrigerant oil.
Lightly coat all seals with mineral-base refrigerant oil before
assembling. Evacuate and charge A/C system.
ORIFICE (EXPANSION) TUBE
CAUTION: If vehicle is equipped with a pressure switch mounted near
orifice tube location, remove switch before heating inlet
tube to prevent damage to switch.
Removal & Installation
1) Discharge A/C system, using approved refrigerant
recovery/recycling equipment. Remove evaporator tube. See
EVAPORATOR TUBE. Using needle-nose pliers or orifice tube remover,
remove orifice tube from evaporator tube.
2) If removal of orifice tube is difficult, remove as much of
the impacted residue as possible. Using a heat gun, apply heat 1/4" (7
mm) from dimples on inlet pipe. DO NOT overheat evaporator tube.
3) To install, reverse removal procedure. Lubricate new "O"
ring with clean refrigerant oil prior to installation. DO NOT soak "O"
Download from Www.Somanuals.com. All Manuals Search And Download.
ring, as this will cause it to expand. Insert short screen end of
orifice tube first. Evacuate, charge, and leak test A/C system.
TORQUE SPECIFICATIONS
TORQUE SPECIFICATIONS
Application
Ft. Lbs. (N.m)
Accumulator Hose Fitting At Evaporator ..................... 28 (38)
Accumulator Tube Bolt ...................................... 10 (14)
Compressor & Condenser Hose Bolt ........................... 24 (33)
Compressor & Condenser Hose Fitting At Condenser ........... 12 (16)
Compressor & Condenser Hose Fitting At Accumulator ......... 12 (16)
Compressor Support Bracket Bolt
Front (5.7L) ............................................. 37 (50)
Rear
3.8L ................................................... 22 (30)
5.7L ................................................... 37 (50)
Evaporator Tube Bolt At Condenser .......................... 12 (16)
Evaporator Tube Bolt At Evaporator ......................... 12 (16)
Evaporator Tube Fitting At Accumulator ..................... 12 (16)
Generator Bracket
5.7L
Mounting Bolts ......................................... 37 (50)
Rear Brace Nut ......................................... 24 (33)
INCH Lbs. (N.m)
Accumulator Bracket Clamp Bolt .............................. 53 (6)
Compressor & Condenser Hose Clip Nut ........................ 71 (8)
Compressor Low Pressure Cut-Off Switch ...................... 53 (6)
Pressure Sensor ............................................. 53 (6)
Refrigerant Service Valve .................................. 97 (11)
Temperature Control Cable Screw ............................. 17 (2)
WIRING DIAGRAMS
Download from Www.Somanuals.com. All Manuals Search And Download.
Fig. 4: Manual A/C-Heater System Wiring Diagram (2000 Camaro &
Firebird With 3.8L Engine)
Download from Www.Somanuals.com. All Manuals Search And Download.
Fig. 5: Manual A/C-Heater System Wiring Diagram (2000 Camaro &
Firebird With 5.7L Engine)
Download from Www.Somanuals.com. All Manuals Search And Download.
Fig. 6: Manual A/C-Heater System Wiring Diagram (2001 Camaro &
Firebird With 3.8L Engine)
Download from Www.Somanuals.com. All Manuals Search And Download.
Fig. 7: Manual A/C-Heater System Wiring Diagram (2001 Camaro &
Firebird With 5.7L Engine)
A00063334
Download from Www.Somanuals.com. All Manuals Search And Download.
|