Chauvet Indoor Furnishings CH 175 User Manual

CH-175  
Color Bank™ 12  
USER MANUAL  
CHAUVET, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A  
(800) 762-1084 – (954) 929-1115  
FAX (954) 929-5560  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEFORE YOU BEGIN  
What is included  
¾
1 x CH-175 with hanging brackets and  
knobs  
Power cord with plug  
Manual  
¾
3 color gels of the following colors;  
yellow, red, blue & green  
12 x JCDR 50W 120V lamps  
Warranty Card  
¾
¾
¾
¾
Unpacking Instructions  
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that  
all parts are present, and have been received in good condition. Notify the shipper immediately and  
retain packing material for inspection if any parts appear damaged from shipping or the carton itself  
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture  
must be returned to the factory, it is important that the fixture be returned in the original factory box  
and packing.  
AC Power  
To determine the power requirements for a particular fixture, see the label affixed to the back plate of  
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average  
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and  
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer  
channel is used solely for a 0% to 100% switch. Before applying power to a  
AC Voltage Switch  
fixture, check that the source voltage matches the fixture’s requirement.  
Check the fixture or device carefully to make sure that if a voltage selection  
switch exists that it is set to the correct line voltage you will use.  
Warning!  
Verify that the power select switch on your unit matches the  
line voltage applied. All fixtures must be connected to circuits  
with a suitable Earth Ground.  
Not all fixtures have a voltage  
select switch. Please be sure to  
connect to the proper voltage.  
Safety Instructions  
Please read these instructions carefully, which includes important  
information about the installation, usage and maintenance?  
Please keep this User Guide for future consultation. If you  
sell the unit to another user, be sure that they also receive  
this instruction booklet.  
Always make sure that you are connecting to the proper  
voltage and that the line voltage you are connecting to is  
not higher than that stated on decal or rear panel of the  
fixture.  
This product is intended for indoor use only!  
To prevent risk of fire or shock, do not expose fixture to  
rain or moisture. Make sure there are no flammable  
materials close to the unit while operating.  
The unit must be installed in a location with adequate  
ventilation, at least 50cm from adjacent surfaces. Be sure  
that no ventilation slots are blocked.  
Always disconnect from power source before servicing or  
replacing lamp or fuse and be sure to replace with same  
lamp source.  
Secure fixture to fastening device using a safety chain.  
Never carry the fixture solely by its head. Use its carrying  
handles.  
Maximum ambient temperature is Ta: 40°. Do not operate  
fixture at temperatures higher than this.  
In the event of serious operating problem, stop using the  
unit immediately. Never try to repair the unit by yourself.  
Repairs carried out by unskilled people can lead to  
damage or malfunction. Please contact the nearest  
authorized technical assistance center. Always use the  
same type spare parts.  
Don’t connect the device to a dimmer pack.  
Make sure power cord is never crimped or damaged.  
Never disconnect power cord by pulling or tugging on the  
cord.  
Avoid direct eye exposure to lamp while it is on.  
Caution!  
There are no user serviceable parts inside the unit. Do not open the housing or  
attempt any repairs yourself. In the unlikely event your unit may require service,  
please contact CHAUVET.  
CH-175 User Manual  
3
2004-09-20/13:36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
INTRODUCTION  
The Color Bank 12 is a compact striplight also referred to as a borderlight. It is ideal for providing  
basic area washes for small stages yet small and lightweight enough for mobile applications. Other  
applications include cove, perimeter, merchandise, and wall wash illumination.  
Features  
12 color gel holders  
16 built-in programs for stand-alone operation  
4 channel chase (3 lamps per channel)  
Light to sound and chase mode  
Chase speed control  
Sound sensitivity knob  
Full On override button  
Footswitch controls Chase, Audio, Full On, & Blackout function (Optional)  
Product Overview  
Hanging bracket  
Lamp/Gel-holders  
Front Panel  
1
2
3
4
1
2
3
4
1
2
3
4
Rear Panel  
Channel LED  
indicator  
Full On override  
button  
Sound  
sensitivity  
5-pin DIN connectors  
for daisy chain linking  
Power connector  
& fuse capsule  
rotary knob  
FOOL SWITCH  
Full on  
220V  
110V  
FULLO N  
SOUND  
SPEED  
Mode LED  
indicator  
- Full ON  
- Audio  
Mode change  
button  
Chase speed  
rotary knob  
Footswitch  
connector  
Voltage switch  
- Chase  
CH-175 User Manual  
4
2004-09-20/13:36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
SETUP  
Lamp  
You will need to install the lamps prior to the initial operation of the fixture. Twelve JCDR 50W 120V  
MR-16 halogen lamps are included.  
Warning!  
When replacing the lamp, please wait 15 minutes after powering down to allow the  
unit to cool down! Always disconnect from main power prior to lamp replacement.  
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp  
with alcohol and wipe it with a lint free cloth before installation.  
LAMP INSTALLATION  
Remove screws  
1) Remove the 2 screws on the lamp/gel-holder face  
plate.  
2) If replacing the lamp, remove old lamp first.  
3) Slide the lamp out of the retaining clips.  
4) Detach the lamp from the lamp socket and replace  
with new lamp.  
5) Replace lamp lamp/gel-holder face plate, align the  
screw holes and fasten the screws.  
6) No lamp alignment is necessary for this fixture  
since the lamp is already optimized inside the  
reflector.  
Color Gels  
The Color Bank includes color gels. Install them to create  
color wash changes during the chase sequence.  
gel  
1) Choose any one of the 4 colors and slide the color  
gel into the open slot on the top side of the lamp/gel  
holder.  
Top Side of  
2) When installing the Color Bank in a horizontal  
lamp/gel  
orientation, make sure that the slotted end of the  
holder  
lamp/gel holder is pointing upwards. This prevents  
the gel from falling out over time.  
3) When installing the Color Bank in a vertical  
orientation and in a tight space, ensure the slotted side is not obstructed and that you maintain  
the ability to insert a color gel.  
Slide switch up or down  
depending on your line voltage.  
Power  
Your product is equipped with switch-selectable AC power  
setting.  
Warning!  
Verify that the power select switch on your unit matches the  
line voltage applied. All fixtures must be connected to  
circuits with a suitable Earth Ground.  
To determine the power requirements for a particular fixture, see the label affixed to the back plate of  
the fixture or refer to the fixture’s specifications chart.  
A fixture’s listed current rating is its average current draw under normal conditions.  
CH-175 User Manual  
5
2004-09-20/13:36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Setup  
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable  
resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100%  
switch.  
Before applying power to a fixture, check that the source voltage matches the fixture’s requirement.  
All fixtures must be connected to circuits with a suitable Earth Ground.  
Mounting  
It is important never to obstruct the fan or vents pathway. Mount the fixture  
Hanging Clamp  
using, a suitable “C” or “O” type clamp. Adjust the angle of the fixture by  
loosening both knobs and tilting the fixture. After finding the desired  
position, retighten both knobs.  
When selecting installation location, take into consideration lamp  
replacement access and routine maintenance.  
Clamp sold separately!  
Safety cables should always be used.  
Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature  
changes or restricted ventilation.  
These holes can be used to  
mount hanging clamps for  
downlighting positions off a  
truss  
Top View  
Front View  
The CH-175 can also be  
used for uplighting. The  
yoke hardware can equally  
serve as floor stands.  
Side View  
CH-175 User Manual  
6
2004-09-20/13:36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
OPERATING INSTRUCTIONS  
Foreword  
The user buttons on this fixture will become “HOT” to the touch after a few minutes of  
operation. It is important to set all manual settings within the first few minutes of  
operation while the unit is cool to warm.  
Operating Modes  
The CH-175 can be operated in three ways.  
A stand-alone mode will listen to sound and run through 16 built in programs.  
Master/Slave mode will allow linking of up to as many units you want in a synchronized light show to  
the sound.  
Can be operated remotely using the CB-FS Footswitch.  
Stand Alone  
CHASE SPEED  
Action  
Notes  
1. Press the MODE button until the Chase,  
When you first power up the fixture the default setting  
will be the Chase mode.  
blue LED turns on.  
2. Adjust the Chase Speed Rotary Knob for  
Chase programs will alternate automatically.  
desired chase speed.  
AUDIO ACTIVATED  
Action ™  
Notes ‡  
1. Press the MODE button until the Audio,  
green LED turns on.  
2. Adjust the Sound Sensitivity Knob for  
optimum performance.  
Master/Slave  
The Master/Slave mode will allow you to link up to as many units you want in a daisy chain fashion. In  
this mode, the first unit in the daisy chain will automatically command all other units following.  
Connecting the CH-175 for (Master/Slave) operation does not require any menu or setting selections.  
Simply connect each unit in a daisy like fashion using a CH-DIN20 5 pin DIN cable. Only the first unit  
in the chain can be controlled by the optional CB-FS footswitch controller.  
Continued on the following page  
CH-175 User Manual  
7
2004-09-20/13:36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
MASTER/SLAVE SETTINGS  
1) Connect the 5 pin plug cable to the LINK (Out) connector of the first fixture.  
2) Connect the other end of the 5 pin cable coming from the first fixture to the LINK (In) connector  
on the next fixture as illustrated below.  
Daisy Chain  
Connection  
Optional Footswitch  
Controller  
Note! The CH-175 and CH-158 can also be linked together.  
CB-FS Color Bank Footswitch (Optional)  
CB-FS PEDALS  
PEDAL  
FUNCTION  
CB-FS FOOTSWITCH  
AUDIO/CHASE  
AUDIO: Activates Audio mode  
CHASE: Activates Chase Speed  
mode  
FULL ON  
All lights will be turned on.  
All lights will be turned off.  
BLACKOUT  
Only the first unit in the chain can be controlled by the CB-FS footswitch controller.  
The CH-158 & CH-175 are compatible in this series and can both be linked together. The first unit  
you choose will control the rest using the CB-FS footswitch controller or in stand-alone mode.  
CH-175 User Manual  
8
2004-09-20/13:36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
APPENDIX  
General Maintenance  
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage  
and environment are contributing factors in determining frequency. As a general rule, fixtures should  
be cleaned at least twice a month. Dust build up reduces light output performance and can cause  
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off  
fixture before conducting maintenance.  
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust  
collected on external vents and internal components. Clean all glass when the fixture is cold with a  
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply  
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical  
surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil  
and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or  
becomes dirty, clean the lamps with an alcohol wipe.  
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to  
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:  
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s  
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean  
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.  
Returns Procedure  
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.  
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products  
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the  
fixture. Be prepared to provide the model number, serial number and a brief description of the cause  
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate  
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to  
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe  
method to use.  
Claims  
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be  
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and  
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim  
for items such as missing component/part, damage not related to shipping, and concealed damage,  
must be made within seven (7) days of receiving merchandise.  
CH-175 User Manual  
9
2004-09-20/13:36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Appendix  
General Troubleshooting  
Applies to  
Foggers  
& Snow  
Dimmers  
& Chaser  
Symptom  
Solution(s)  
Lights  
Controllers  
Auto shut off  
Check fan thermal switch reset  
9
Beam is very dim or not Clean optical system or replace lamp  
9
bright  
Check 220/110v switch for proper setting  
Breaker/Fuse keeps  
blowing  
Check total load placed on device  
9
9
Chase is too slow  
Check users manual for speed adjustment  
9
9
9
9
Device has no power  
Check for power on Mains.  
9
Check device’s fuse. (internal and/or external)  
Lamps cuts off  
sporadically  
Possible bad lamp or fixture is overheating.  
Lamp may be at end of its life.  
9
9
Motor movements are  
jerky or jumpy  
Possible bad motor driver or sensors  
Check polarity switch on controller  
9
Moves slow  
No flash  
Check 220/110v switch for proper setting  
Re-install bulb, may have shifted in shipping  
9
9
No light output  
Check slip ring & brushes for contact  
Install bulb  
9
Call service technician  
Relay will not work  
Check reset switch  
9
Check cable connections  
Remote does not work  
Make sure connector is firmly connected to device  
Check for damages possibly incurred during shipping  
9
9
9
Unit wobbles when  
rotating  
CH-175 User Manual  
10  
2004-09-20/13:36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix  
Technical Specifications  
WEIGHT & DIMENSIONS  
Length........................................................................................................................... 140 mm (5.51 in)  
Width ........................................................................................................................ 1100 mm (43.31 in)  
Height ........................................................................................................................... 175 mm (6.89 in)  
Weight ........................................................................................................................... 6.1 Kg (13.5 lbs)  
POWER  
Switch-selectable power setting ....................................................................115V 60 Hz or 230V 50 Hz  
AC input..............................................................................................................3-prong IEC 60320 C14  
LAMPS  
JCDR-50W-120V x (12) .................................................................................... 1500 hr, 50W 110-130V  
JCDR-50W-230V x (12) .................................................................................... 1500 hr, 50W 220-240V  
THERMAL  
Maximum ambient temperature..........................................................................................65°C (149° F)  
FUSE  
Main (115V)..........................................................................................20mm Glass 7A 125V Fast Blow  
Main (230V)..........................................................................................20mm Glass 5A 250V Fast Blow  
ORDERING INFORMATION  
Color Bank 12.............................................................................................................................. CH-175  
Fuse 7A ............................................................................................................................P170FUSE007  
Fuse 5A ............................................................................................................................P170FUSE005  
OPTIONS  
Color Bank Footswitch...................................................................................................................CB-FS  
CH-175 User Manual  
11  
2004-09-20/13:36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Bose Car Amplifier SA 4 User Manual
Bostitch Air Compressor 175869REVA User Manual
Breville Espresso Maker ME 67 User Manual
Broilmaster Outdoor Cart B100613 3 1203 User Manual
Canon Fax Machine H12250 User Manual
Canon Printer MultiPASSTM L6000 User Manual
Carrier Access Network Router Terminal Server Router User Manual
Casio Computer Hardware DQ 970 User Manual
Casio Musical Toy Instrument CGP700 User Manual
Char Broil Gas Grill 11601558 User Manual