1. Before You Begin
Unpacking Instructions
Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
Note:
If you should require sending any items back to CHAUVET, call CHAUVET for
a (RMA) Return Merchandise Authorization number. The factory will not allow
any shipments without an RMA.
Your shipment includes the following:
•
•
•
•
1 x DMX Mega Strobe™ II
CH-750B lamp (installed)
Warranty Card
Users Manual
Contact Us
World Wide
General Information
Chauvet Lighting
3000 North 29th Court
Hollywood, FL 33020
voice: 954.929.1115
fax:
954.929.5560
toll free: 800.762.1084
Technical Support
Chauvet Lighting
3000 North 29th Court
Hollywood, FL 33020
voice: 954.929.1115 (Press 4)
fax:
954.929.5560 (Attention: Service)
World Wide Web
ST-800X User Manual
3
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
Before You Begin
Important Safety Information
This product is designed for professional use. It is not intended for use in a household environment.
This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet
radiation, lamp explosion, and injury from falls. Read this manual before installing or powering the
fixture, follow the safety precautions listed below and observe all warnings in this manual and on the
fixture. If you have any questions about how to operate the fixture safely, please contact CHAUVET.
Protection against Electric Shock
•
Always disconnect from AC power source before servicing or replacing lamp or fuse and be sure
to replace with same lamp source.
•
•
All Class I fixtures must be connected to circuits with a suitable Earth Ground.
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit while operating.
•
Do not operate the fixture if covers are open or if any internal component is missing or damaged:
an unshielded discharge lamp emits dangerous UV radiation that can cause burns and eye
damage.
•
•
Make sure power cord is never crimped or damaged.
Never disconnect power cord by pulling or tugging on the cord.
Protection against Fire & Burns
•
This product is designed to be used with very specific lamp(s). Use of any other type of lamp not
stated in this manual may create a fire hazard due to possible risk of lamp explosion. Using the
wrong type of lamp in this product VOIDS the warranty.
•
•
Always make sure that you are connecting to the proper voltage and that the line voltage you are
connecting to is not higher than that stated on decal or rear panel of the fixture.
The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent
surfaces. Be sure that no ventilation slots are blocked.
•
•
Maintain a minimum distance of 1 meter (3.28 feet) from combustible materials.
Allow this product to cool for a minimum of 15 minutes before opening, handling or removing the
lamp in this product.
•
Maximum ambient temperature is Ta: 40°. Do not operate fixture at temperatures higher than
this.
Protection against exposure to (UV) Ultraviolet Radiation
•
•
Avoid direct eye exposure to lamp while it is on.
Do not operate the fixture if covers are open or if any internal component is missing or damaged.
Protection against Injury to persons
•
•
Secure fixture to fastening device using a safety chain.
A hot lamp is an explosion hazard. Do not open fixture for a minimum of 15 minutes after
switching off. Wear eye and hand protection when re-lamping.
•
•
Fixture surface may reach temperatures of up to 160° C (320° F). Handle fixture after it cools.
In the event of serious operating problem, stop using the unit immediately. Never try to repair the
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction.
Please contact the nearest authorized technical assistance center. Always use the same type
spare parts.
Caution!
There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET.
ST-800X User Manual
4
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Introduction
Features
•
•
•
•
•
2-channel 750-watts DMX-512 strobe light
Adjustable flash rate 1-20fps
Variable electronic dimmer (0-100%)
Manual dimmer and flash rate knobs
10 million-flash life
DMX Channel Summary
Channel
Function
1
2
Flash Rate
Flash Intensity
ST-800X User Manual
5
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Product Overview
Hanging Yoke
Safety Glass
DMX In
AC Input
DMX Out
Side View
ON – 60Hz
OFF – 50Hz
DMX Signal Termination
ON – Active
Strobe Intensity
Speed Rotary knob
OFF – Non-active
DMX ADD
ON
OFF
DIM
SPEED
2
2
3
4
5
6
7
8
9
1
1
Side View
ST-800X User Manual
6
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Setup
AC Power
Warning!
Verify that the power requirement label on your unit matches the line voltage
applied. All fixtures must be connected to circuits with a suitable Earth Ground.
•
To determine the power requirements for a particular fixture, see the label affixed to the back plate
of the fixture or refer to the fixture’s specifications chart.
•
•
A fixture’s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.
•
•
Before applying power to a fixture, check that the source voltage matches the fixture’s
requirement.
All fixtures must be connected to circuits with a suitable Earth Ground.
Power Cable Configuration
CABLE
BROWN
Pin
Live
International
Screw Color
Yellow or Brass
Silver
L
N
BLUE
Neutral
Earth
YELLOW/GREEN
EG (Ground)
Green
Mounting
Orientation
This fixture can be mounted on a truss using a clamp in any position or against a flat surface using
the brackets provided.
Rigging
The fixture includes a mounting yoke to which 1 rigging clamp can
be bolted. You must supply your own clamp and make sure the
clamp is capable of supporting the weight of this fixture. You can
order C-clamps from any CHAUVET dealer or distributor.
Hanging Clamp
1.
Block access below the work area and use suitable and stable
platform when installing or servicing fixture.
2.
3.
4.
5.
Align the clamp screw with the center hole on the yoke and tighten.
Verify the structure can hold 10 times the weight of all to-be installed fixtures.
Adjust the angle on the yoke arm as necessary.
Always use a safety cable or chain as a secondary source of attachment. The safety cable must hold 10
times the weight of the fixture. If safety cable attachment point is provided that is permanently affixed to
the surface or body of the fixture, use that instead of looping through a hanging yoke/arm.
ST-800X User Manual
7
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller
or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The
combined number of channels required by all the fixtures on a serial data link determines the number
of fixtures the data link can support.
The Thruster™ fixtures use 2 channels of DMX control.
Important: Fixtures on a serial data link must be daisy chained in one single line. To
comply with the EIA-485 standard no more than 32 devices should be
connected on one data link. Connecting more than 32 fixtures on one serial
data link without the use of a DMX optically isolated splitter may result in
deterioration of the digital DMX signal.
Maximum recommended serial data link distance: 500 meters (1640 ft.)
Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX
cables directly from a dealer/distributor or construct your own cable. If you choose to create your own
cable please use data-grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
DMX Data Cable
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications.
Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will
have the following characteristics:
•
•
•
•
•
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor and shield – 55 pF/ft.
Maximum resistance of 20Ω / 1000 ft.
Nominal impedance 100 - 140Ω
Cable Connectors
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
Resistance 120
1
3
DMX connector configuration
ohm 1/4w between
pin 2 (DMX -) and
pin 3 (DMX +) of
the last fixture.
2
COMMON
DMX +
1
1
3
INPUT
3
OUTPUT
Termination reduces signal errors and
to avoid signal transmission problems
and interference, it is always
2
2
DMX -
advisable to connect a DMX signal
CAUTION Do not allow contact between the common and the fixture’s chassis ground.
Grounding the common can cause a ground loop and your fixture to perform
erratically. Test cables with OHM meter to verify correct polarity and to make
sure the pins are not grounded or shorted to the shield or each other.
ST-800X User Manual
8
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
3-Pin to 5-Pin Conversion Chart
Note!
If you use a controller with a 5 pin DMX output connector, you will need to use
a 5 pin to 3 pin adapter. CHAUVET Model No: DMX5M.
The chart below details a proper cable conversion:
3 PIN TO 5 PIN CONVERSION CHART
Conductor
3 Pin Female (output)
Pin 1
5 Pin Male (Input)
Pin 1
Ground/Shield
Data ( - )signal
Data ( + ) signal
Do not use
Pin 2
Pin 3
Pin 2
Pin 3
Do not use
Do not use
Do not use
Setting up a DMX Serial Data Link
Universal DMX Controller
1. Connect the (male) 3 pin connector side of
the DMX cable to the output (female) 3 pin
connector of the controller.
2. Connect the end of the cable coming from
the controller which will have a (female) 3
pin connector to the input connector of the
next fixture consisting of a (male) 3 pin
connector.
This drawing provides a
general illustration of
the DMX Input/Output
panel of a lighting
3. Then, proceed to connect from the output
as stated above to the input of the following
fixture and so on.
CHAUVET Certified DMX Data Cables
Order Code
DMX1.5
DMX4.5
DMX10
Description
DMX Cable 1.5m/4.9ft
DMX Cable 4.5m/14.8ft
DMX Cable 10m/32.8ft
Continue the link
Standalone/Master-Slave Fixture Linking
4. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector
of the first fixture.
5. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then,
proceed to connect from the output as stated above to the input of the following fixture and so on.
Fixtures displayed are for illustration purpose only!
Often, the setup for Master-Slave
and Standalone operation
requires that the first fixture in the
chain be initialized for this
purpose via either settings in the
control panel or DIP-switches.
Secondarily the fixtures that
follow may also require a slave
setting. Please consult the
“Operating Instructions” section
in this manual for complete
instructions for this type of setup
and configuration.
ST-800X User Manual
9
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
Lamp Installation
When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp
with alcohol and wipe it with a lint free cloth before installation.
Unscrew and release
lamp wires from the main
PCB.
Unscrew grounding wire
from PCB.
Remove the 4 corner
screws to allow the
temporary removal of the
safety glass cover.
CH-750B Lamp
Lamp is removed and replaced through the front of the
fixture. You must first remove the glass cover. Attempt to
remove the lamp after you have released all wire leads
from the PCB. Push back on both spring terminal ends
inside the lamp reflector to release the linear lamp from
the grip of both spring terminals and pull lamp outwards
as you apply the pressure. Repeat procedure to replace
and reconnect wire leads to the appropriate terminals on
the PCB. Make sure wires are tightly screwed onto the
PCB.
ST-800X User Manual
10
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Operating Instructions
Operating Modes
•
•
•
A stand-alone mode will allow the user to set the desired speed and intensity.
Master/Slave output provides for unison triggering of chained strobes.
DMX-512 control protocol allows remote control of the fixture via a universal DMX controller.
Stand Alone
The Stand Alone mode is activated automatically when the fixture is absent of a CH-751, SC-1000M
or a DMX controller. Note! All dipswitches
must be set to the OFF position. The
strobe speed and strobe intensity can be
adjusted and they are located on the side
of the fixture. The strobe will continue to
DIM
SPEED
operate at the user set levels until it is
turned off. Upon turning the strobe back on
the unit will continue in the previously set levels.
Unison Strobe (Master/Slave)
The Unison strobe mode will allow you to link additional units in a daisy chain fashion. Simply,
connect each fixture in a daisy like fashion using certified DMX XLR cable. Be sure that all DMX
dipswitches are set to the OFF position.
DIM
SPEED
DMX Out
DMX In
DMX Control Mode
In this mode the user can control the strobe light remotely. Both the intensity and the flash rate can be
programmed as part of a scene or a cue. To blackout the unit entirely it requires both intensity and
flash rate to be at 0 levels.
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector
of the controller.
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector
to the input connector of the next fixture consisting of a (male) 3 pin connector.
3. Then, proceed to connect from the DMX output as stated above to the DMX input of the following
fixture and so on.
4. If you need help setting the DMX address read the section titled “Setting the DMX address” in this
Chapter.
ST-800X User Manual
11
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Setting the DMX Address
Each fixture requires a "start address" from 1 to 511. A fixture requiring one or more channels for
control begins to read the data on the channel indicated by the start address. For example, a fixture
that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would
read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose start addresses so that the
channels used do not overlap and notate the start address selected for future reference. If this is
your first time setting a DMX address then read the DMX Primer in the Appendix Section.
The ST-800X is controlled using 2 channels of DMX, therefore you would space fixtures every two
channels. For example: Fixture 1 = (001), Fixture 2 = (003), Fixture 3 = (005) and so on.
Visit the section titled; Binary & DIP-switch Addressing on page 14 & Binary Addressing Quick
Reference Chart on page 15 to quickly determine the binary DIP-switch settings for addressing your
fixture.
ST-800X User Manual
12
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Appendix
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe
method to use.
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.
Maintenance
To maintain optimum performance and minimize wear, fixtures should be cleaned frequently. Usage
and environment are contributing factors in determining frequency. As a general rule, fixtures should
be cleaned at least twice a month. Dust build up reduces light output performance and can cause
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off
fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when the fixture is cold with a
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical
surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil
and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or
becomes dirty, clean the lamps with an alcohol wipe.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
ST-800X User Manual
13
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
Binary & DMX DIP-switch Addressing
Each DIP-switch has an associated value. Adding the value of each switch in the ON position will
provide the final address. Determining which switches to toggle ON given a specific desired address
or value can be accomplished in the following manner. By subtracting the largest switch value
possible from the selected start address which does not cause a negative number.
Alternatively, using the “Binary Addressing Quick Reference Chart” in the Appendix section of this
manual, you can go directly to DIP-switch settings associated with all 512 values available.
EXAMPLE ADDRESS
Address 10
Pin # 4 = 8
Pin # 2 = 2
ON
2
3
4
5
6
7
8
9 10
1
Total
= 10
Address 24
Pin # 5 = 16
Pin # 4 = 8
ON
2
3
4
5
6
7
8
9 10
1
Total
= 24
Resolving address
using simple math.
233 – (128) = 105, Turn ON Dip # 8
105 – (64) = 41, Turn ON Dip # 7
41 – (32) = 9, Turn ON Dip # 6
9 – (8) = 1, Turn ON Dip # 4
DIP SWITCH
(DMX VALUE)
1
2
3
1
2
4
Address 233
1 – (1) = 0, Turn ON Dip # 1
4
8
5
6
7
8
9
10
16
32
64
128
256
You will most likely use the first available
number which maybe number 1. This
number was selected for tutorial
purposes.
ST-800X User Manual
14
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
Binary Addressing Quick Reference Chart
DMX & Binary Address Quick Reference Chart
DIP-switch Position
DMX DIP-SWITCH SET #9
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
0=OFF
1=ON
#8
#7
#6
X=OFF or ON
#1 #2 #3 #4 #5
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
32 64
33 65
34 66
35 67
96
97
98
99
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
1
2
3
4
5
6
7
8
9
36 68 100
37 69 101
38 70 102
39 71 103
40 72 104
41 73 105
10 42 74 106
11 43 75 107
12 44 76 108
13 45 77 109
14 46 78 110
15 47 79 111
16 48 80 112
17 49 81 113
18 50 82 114
19 51 83 115
20 52 84 116
21 53 85 117
22 54 86 118
23 55 87 119
24 56 88 120
25 57 89 121
26 58 90 122
27 59 91 123
28 60 92 124
29 61 93 125
30 62 94 126
31 63 95 127
DIP-switch Position
DMX Address
ST-800X User Manual
15
2007-03-07/10:58
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix
DMX Channel Values
CHANNEL
VALUE
FUNCTION
Flash Rate
Slow <> Fast
1
000 Ù 255
000 Ù 255
Flash Intensity
Blackout <> Full Brightness
2
Technical Specifications
WEIGHT & DIMENSIONS
Length........................................................................................................................... 320 mm (12.6 in)
Width ............................................................................................................................ 207 mm (8.15 in)
Height ........................................................................................................................... 136 mm (5.35 in)
Weight ........................................................................................................................... 2.6 Kgs (5.8 lbs)
Master Pack................................................................................................... (4 pcs) 10.9 Kgs (24.0 lbs)
POWER
Operating Voltage .............................................................................................. 110V or 230V 50/60 Hz
AC input........................................................................................................................... IEC 60320 C14
THERMAL
Auto-reset thermal switch - maximum ambient temperature................................................ 40° (104° F)
FUSE
Main............................................................................................................. 20mm Glass 20A Fast Blow
CONTROL & PROGRAMMING
Data input ................................................................................................ locking 3-pin XLR male socket
Data output....................................................................................................... 3-pin XLR female socket
Data pin configuration ..............................................................................pin 1 shield, pin 2 (-), pin 3 (+)
Protocols........................................................................................................................ DMX-512 USITT
DMX Channels .......................................................................................................................................2
ORDERING INFORMATION
DMX Mega Strobe II™ ...............................................................................................................ST-800X
Replacement bulb .....................................................................................................................CH-750B
1 channel strobe controller.......................................................................................................... CH-751
4 channel strobe controller............................................................................................. SC-1000MONO
Technical Support
Address: Service Dept.
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)
Support (Email): [email protected]