Carrier Access Network Router 3104s User Manual

Adit 3104  
QUICK START GUIDE  
Part Number: 002-0219-0410  
Product Release: 1.6  
September 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Unpacking and Inspection  
Unpacking and Inspection  
WARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES.  
1. Inspect containers for damage during shipment. Report any damage to the freight carrier for  
possible insurance claims.  
2. Compare packing list with office records. Report any discrepancies to the office.  
3. Open shipping containers, be careful not to damage contents.  
4. Inspect contents and report any damage.  
5. If equipment must be returned for any reason, carefully repack equipment in the original  
shipping container with original packing materials if possible.  
6. If equipment is to be installed later, replace equipment in original shipping container and store  
in a safe place until ready to install.  
Electrostatic Discharge (ESD) Precautions  
ESD can damage processors, circuit cards, and other electronic components. Always  
observe the following precautions before installing a system component.  
1. Do not remove a component from its protective packaging until ready to  
install it.  
2. Wear a wrist grounding strap and attach it to a metal part of the system unit  
before handling components. If a wrist strap is not available, maintain contact with the system  
unit throughout any procedure requiring ESD protection.  
WARNING! INTEGRATED CIRCUITS (ICS) ARE EXTREMELY SUSCEPTIBLE TO ELECTROSTATIC  
DISCHARGE. UNLESS YOU ARE A QUALIFIED SERVICE TECHNICIAN WHO USES TOOLS AND  
TECHNIQUES THAT CONFORM TO ACCEPTED INDUSTRY PRACTICES, DO NOT HANDLE ICS.  
The ESD warning label appears on packages and storage bags that contain static-sensitive products and  
components.  
Installation Environment  
The environment in which you are installing the Adit 3000 must meet the following conditions:  
z Operating temperature range: 32° to 104° F (0° to 40° C)  
z Storage temperature range: -40° to 158° F (-40° to 70° C)  
z Maximum operating altitude: 10,000 ft. (3,048 m)  
z Maximum non-operating altitude: 40,000 ft. (12,192 m)  
z Relative humidity (non-condensing) range: 0 to 95%  
WARNING! THE ADIT 3000 IS DESIGNED FOR WALL AND RACK MOUNTING ONLY. IT IS NOT  
DESIGNED FOR DESKTOP USE.  
4
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Quick Start  
User Safety  
User Safety  
CAUTION! WHEN USING YOUR TELEPHONE EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD  
ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PERSONS,  
INCLUDING THE FOLLOWING:  
z Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or  
laundry tub, in a wet basement or near a swimming pool.  
z Avoid using a telephone (other than a cordless type) during an electrical storm. There may be  
a remote risk of electric shock from lightning.  
z Do not use the telephone to report a gas leak in the vicinity of the leak.  
z Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a  
fire. They may explode. Check with local codes for possible special disposal instructions.  
z Refer to the installation section of this manual for a safe and proper installation procedure. All  
wiring external to this equipment should follow the current provision of the National Electrical  
Code.  
Installation  
The following are instructions for a compliant installation of the Adit 3104. Please note the following  
warnings, before installing the unit.  
For wall and rack mount instructions, use the links listed below to the appropriate section:  
WARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES. SEE  
WARNING! THE ADIT 3104 DS1 NETWORK INTERFACE PORTS ARE CERTIFIED WITH ACTA,  
INDUSTRY CANADA AND UL FOR DIRECT CONNECTION TO PUBLIC DIGITAL NETWORKS. TO PREVENT  
EQUIPMENT DAMAGE FROM LIGHTNING SURGES, AC INDUCTION OR POWER LINE CONTACT, UTILIZE  
LISTED PRIMARY PROTECTORS AT THE BUILDING ENTRANCE WITH MINIMUM 4 OHM CURRENT-  
LIMITING AND MAXIMUM 600V IMPULSE BREAKDOWN AT 1000V/USEC. THE ADIT 3104 DS1 PORTS  
COME EQUIPPED WITH SECONDARY OVERVOLTAGE AND OVERCURRENT PROTECTION. THE  
INSTALLATION IS REQUIRED TO MEET LOCAL OR NATIONAL ELECTRIC CODES FOR COMMUNICATION  
SYSTEMS.  
WARNING! THE ADIT 3104 FXS INTERFACE PORTS ARE INTENDED TO SERVE INDOOR  
COMMUNICATION CONDUCTORS ONLY. OVERVOLTAGE AND OVERCURRENT PROTECTION IS  
PROVIDED TO PREVENT EQUIPMENT DAMAGE FROM LIGHTNING SURGES OR AC POWER LINE  
CONTACT INSIDE BUILDINGS. THE FXS PORTS ARE NOT SUITABLE FOR CONNECTION TO EXPOSED  
OUTDOOR COMMUNICATION CONDUCTORS.  
Adit 3104 - Release 1.6  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quick Start  
Installation  
Compliant Installation  
NOTE: It is important the DS1/E1 Network Interface Cables are secured separately from the  
power and Signal Cables.  
1. Inspect the unit.  
for detailed instructions.  
3. Ground the unit. See Grounding the Unit on page 12.  
WARNING! THE ADIT 3104 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE  
PROTECTION OF USERS AND SERVICE PERSONNEL. REFER TO Grounding the Unit ON PAGE 12 FOR  
DETAILED INSTRUCTIONS.  
4. Connect DS1 (T1), Ethernet and Amphenol connectors as needed.  
Note: if Amphenol (25-pin telco) connector is used, a ferrite bead is required to meet  
compliance (see graphic above).  
5. Connect RS-232 connector and open Terminal Emulator software on your PC. Note: With this  
running first, you can monitor the boot process.  
6. Connect Power to the unit.  
7. Monitor the boot process on your PC, when complete the status light should be green.  
8. For any software enabled features, enter the key command. See the key command in the Adit  
3000 CLI Reference Manual, for detailed information.  
9. To verify use the show version command.  
10. Now you can proceed to provisioning the unit. See Basic Configuration on page 23 for  
information.  
Ferrite Beads  
To be compliant with EMI standards, a ferrite bead is required on the following cable:  
Ferrite bead shipped with Adit chassis:  
Ferrite Provided  
Part Number  
Intended For  
1 large  
P/N 010-0051  
25-pair Telco cable (connector on the front of the Adit).  
6
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quick Start  
Installation  
Wall Mounting  
Before beginning the mounting process, verify that the installation area is a stable environment, clean  
and free from extremes of temperature, shock, vibration and EMI. See Installation Environment on  
page 4.  
Mounting Bracket  
Back of unit  
Front of unit  
Leave adequate space  
at the front/back for  
access to connectors  
The Adit 3000 is delivered with mounting brackets that can easily be attached for quick and easy wall  
mounting, as shown in the illustration above.  
To install the unit to the wall:  
1. Attach the wall mount brackets to the Adit 3000, with wall attachment flange pointing away  
from the unit, as shown above. Attach with 4 screws provided (2 for each bracket).  
2. Mount the unit to the wall using appropriate mounting screws (not included). Note: it is  
acceptable to mount on drywall with suitable anchor-type mounting screws.  
NOTE: The Adit 3000 must be mounted with the brackets on the top and bottom, as shown  
above.  
Adit 3104 - Release 1.6  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Installation  
Rack Mounting (Optional Feature)  
NOTE: Rack mounting kits are available for both 19 and 23 inch racks. 1 Rack Unit (RU) of spacing  
is required above the Adit 3000 in the Rack Mount Unit.  
To rack mount the Adit 3000, follow the instructions below:  
1. Attach bracket ears to Rack Mounting Tray using four #10-32 x 1/4" screws on each side. The  
Mounting Ears can be used for both a 19 or 23 inch rack. The drawing below shows a top view  
of the 2 versions.  
Mounting Ear  
Rack Mounting Tray  
23 in rack  
Rack Mount Tray  
Front  
screws  
screws  
Mounting Ear  
Mounting Ear  
19 in rack  
Rack Mount Tray  
screws  
screws  
Front  
Mounting Ear  
Mounting Ear  
2. Remove wall mount and screws from Adit 3000 unit.  
8
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Installation  
3. Place the Adit 3000 on the Tray Slide and attach with the 4 screws removed in step 2.  
screws  
screws  
Tray Slide  
4. Slide the assembled piece (Adit 3000 and Tray Slide) onto the installed Rack Mounting Tray.  
5. Secure the Tray Slide to the Rack Mounting Tray with the attached screws on the Tray Slide.  
NOTE: the mounting brackets are designed to not allow units to be mounted closer than  
recommended.  
Adit 3104 - Release 1.6  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Installation  
Adit 3104, 3200 and 3400 Battery Backup  
Note: This is an Optional Feature.  
The Adit 3104, 3200 and 3400 Battery Backup (P/N 730-0132), is a wall-mount battery backup unit to  
provide up to 8 hours battery backup.  
Please see the Battery Backup User Manual for product information and installation instructions, which  
is provided with unit.  
10  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Chassis Overview  
Chassis Overview  
Front  
Alarm  
Status  
(1) DS1/E1 (WAN)  
(E1-future)  
(4) 10/100Base-T  
Ethernet (LAN)  
Tip & Ring Telco  
Connector  
Reset  
(1) 10/100Base-T  
Ethernet (WAN)  
Back  
RS-232  
Power/Battery/Status  
Ground  
Management  
Port  
Adit 3104 - Release 1.6  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Interface Connectors  
Interface Connectors  
Front of Adit  
z (1) DS1 WAN port (RJ-48C). Note: E1 will be in a future release.  
z (1) 10/100Base-T WAN port (RJ-45)  
z (4) 10/100Base-T switched LAN ports (RJ-45)  
z Tip & Ring Analog Interface equipped with standard 25-pair Telco Connector  
Back of Adit  
z RS-232 craft port connector for local management  
z Power input connector  
z Ground connector  
Grounding the Unit  
WARNING! THE ADIT 3104 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE  
PROTECTION OF USERS AND SERVICE PERSONNEL.  
Chassis ground is located on the back of the unit.  
To ground the unit:  
1. Connect a minimum 14 AWG ground  
wire with a #8 ring tongue terminal (not  
included) to the chassis ground on the  
back of the unit. Secure with the 8-32  
screw and lock washer provided.  
Chassis  
Ground  
2. Connect the opposite end of the ground  
wire to a suitable earth grounding point  
such as a building grounding electrode,  
metal water pipe, or metal building  
structure that is in compliance with article 250 of NEC.  
12  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quick Start  
Interface Connectors  
Power  
The Adit 3000 is powered by a limited -48 VDC Power source. The  
following options are available:  
z AC/DC Converter  
z Battery Backup module  
AC/DC Converter  
An AC/DC Converter generates 48VDC from any worldwide AC power source.  
To connect AC power:  
1. Plug power connector from AC/DC converter into rear of Adit 3000.  
2. Connect AC/DC converter to wall outlet.  
3. A green light should appear on the Status LED on the front of the unit.  
PIN 10, ORANGE  
PIN 5, BLACK  
CAUTION! INCORRECT WIRING OF CORD MAY CAUSE EXTERNAL FUSE FAILURE.  
WARNING! POSSIBLE SHOCK HAZARD EXISTS, PLEASE FOLLOW INSTRUCTIONS CAREFULLY.  
To connect -48 VDC power:  
1. Wire appropriate connector to open end of the DC Power cable.  
Orange = -48  
Black = Ground (+)  
2. Plug the DC power connector in the -48 VDC input power connector.  
3. Apply power to connector from -48 VDC power source.  
4. A green light should appear on the Status LED on the front of the unit.  
WARNING! EXTERNAL FUSE PROTECTION IS REQUIRED ON THE 48VDC INPUT WHEN  
CONNECTED TO A DC POWER SOURCE NOT SUPPLIED BY CARRIER ACCESS.  
Fuse Recommendations, or equivalent:  
Recommended Fuse  
Littelfuse 48101.5  
Bussman GMC-1.5A  
AMP Rating  
1.5 Amp  
1.5 Amp  
Battery Connection  
The Adit 3000 Battery connection is provided for Battery Backup. See Adit 3104, 3200, 3300 and 3400  
Battery Backup on page 8 for additional information.  
Adit 3104 - Release 1.6  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Interface Connectors  
25-Pair Telco Connector  
Tip and Ring Analog Interfaces equipped with standard 25-pair Telco Connectors (female) for  
connection to key systems, fax machines, modems, and PBXs.  
Circuit connections are made at the 25-pair telco  
connectors. A standard 25-pair telephone cable with RJ-  
21X wiring and a male D-type connector at the Adit 3000  
26  
50  
25  
end is required. The pinouts are as follows:  
1
Pair  
Pin Function  
Color Code  
Pair  
Pin Function  
Color Code  
1
26  
1
Tip Channel 1  
Ring Channel 1 Blue/White  
White/Blue  
14  
39  
14  
Tip Channel 14 Black/Brown  
Ring Channel 14 Brown/Black  
2
3
27  
2
Tip Channel 2  
Ring Channel 2 Orange/White  
White/Orange  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
40  
15  
Tip Channel 15 Black/Slate  
Ring Channel 15 Slate/Black  
28  
3
Tip Channel 3  
Ring Channel 3 Green/White  
White/Green  
41  
16  
Tip Channel 16 Yellow/Blue  
Ring Channel 16 Blue/Yellow  
4
29  
4
Tip Channel 4 White/Brown  
42  
17  
Tip Channel 17 Yellow/Orange  
Ring Channel 17 Orange/Yellow  
Ring Channel 4 Brown/White  
Tip Channel 5 White/Slate  
5
30  
5
43  
18  
Tip Channel 18 Yellow/Green  
Ring Channel 18 Green/Yellow  
Ring Channel 5 Slate/White  
6
31  
6
Tip Channel 6 Red/Blue  
44  
19  
Tip Channel 19 Yellow/Brown  
Ring Channel 19 Brown/Yellow  
Ring Channel 6 Blue/Red  
Tip Channel 7 Red/Orange  
7
32  
7
45  
20  
Tip Channel 20 Yellow/Slate  
Ring Channel 20 Slate/Yellow  
Ring Channel 7 Orange/Red  
8
33  
8
Tip Channel 8 Red/Green  
46  
21  
Tip Channel 21 Violet/Blue  
Ring Channel 21 Blue/Violet  
Ring Channel 8 Green/Red  
Tip Channel 9 Red/Brown  
9
34  
9
47  
22  
Tip Channel 22 Violet/Orange  
Ring Channel 22 Orange/Violet  
Ring Channel 9 Brown/Red  
10  
11  
12  
13  
35  
10  
Tip Channel 10 Red/Slate  
Ring Channel 10 Slate/Red  
48  
23  
Tip Channel 23 Violet/Green  
Ring Channel 23 Green/Violet  
36  
11  
Tip Channel 11 Black/Blue  
Ring Channel 11 Blue/Black  
49  
24  
Tip Channel 24 Violet/Brown  
Ring Channel 24 Brown/Violet  
37  
12  
Tip Channel 12 Black/Orange  
Ring Channel 12 Orange/Black  
50  
25  
Reserved  
Violet/Slate  
Slate/Violet  
38  
13  
Tip Channel 13 Black/Green  
Ring Channel 13 Green/Black  
14  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Interface Connectors  
RS-232 Craft Port (Female DB-9)  
The RS-232 craft port connector (female) is for connection to an external PC or Hayes-compatible  
modem for local or remote configuration, management, and performance monitoring using the Adit  
3000 Command Line Interface (CLI).  
The RS-232 craft port connects via a female DB-9 connector on the Adit  
3000.  
1
5
6
9
The pinouts are as follows:  
Pin Number  
Direction  
Outbound  
Outbound  
Inbound  
Inbound  
N/A  
Description  
1
2
3
4
5
6
7
8
9
Carrier Detect  
Receive Data  
Transmit Data  
Data Terminal Ready  
Signal Ground  
Data Set Ready  
Request to Send  
Clear to Send  
Outbound  
Inbound  
Outbound  
N/C  
Not connected  
Adit 3104 - Release 1.6  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Interface Connectors  
DS1/E1 Connection Ports  
1
8
Each DS1/E1 connection port is equipped with a standard RJ-48C (female) on the  
Adit 3000 unit. Note: E1 will be available in a future release.  
The pinouts are as follows:  
DS1/E1 RJ-48C  
The pinouts are as follows:  
Pin  
1
Name  
Description  
Receive Ring  
Receive Tip  
N/C  
Receive from DS1 network  
Receive from DS1 network  
Not connected  
2
3
4
Transmit Ring  
Transmit Tip  
N/C  
To DS1 network  
5
To DS1 network  
6-8  
Not connected  
The LEDs are as follows (left LED only):  
State  
Description  
Off  
Off line  
Normal  
Green  
Red  
Loss of Signal (LOS)  
Yellow  
Bipolar Violation (BPV)  
Flashing Green  
Flashing Yellow  
Flashing Red (Slow)  
Flashing Red (Fast)  
Loopback active  
Yellow Alarm (Remote Alarm Indication)  
Loss of Frame (LOF) or Alarm Indication Signal (AIS)  
Self-test Failure  
16  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Reset Button  
10/100Base-TX Ethernet  
The 10/100Base-TX Ethernet (female) ports provide connectivity for Router  
WAN and/or LAN ports and for management connection via Telnet and/or  
SNMP to a Network Management System.  
1
1
8
Ethernet (RJ-45)  
The pinouts are as follows:  
Note: This is a hub pinout, you will need a straight cable to connect to a PC.  
Pin  
1
Name  
Description  
Receive +  
Receive -  
Transmit +  
N/C  
Receive from network  
Receive from network  
Transmit to network  
Not connected  
2
3
4-5  
6
Transmit -  
N/C  
Transmit to network  
Not connected  
7-8  
The LEDs are as follows:  
LED  
State  
Description  
Left LED  
The left LED shall show Link Status.  
Off  
Link Down  
Green  
Link Up  
Flashing Green  
Yellow  
Traffic on Link  
Collision status  
Right LED  
The right LED shall indicate Link Speed.  
Off  
10 Mbit/sec, down or not connected  
100 Mbit/sec  
Green  
Reset Button  
The system can be reset by pressing the reset button located on the front panel.  
Adit 3104 - Release 1.6  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Alarm/Status LEDs  
Alarm/Status LEDs  
LED  
State  
Description  
Critical Off  
Red  
No critical alarms present  
Critical alarms present. Critical alarms include:  
user-configured manor environmental inputs.  
Major  
Off  
No major alarms present  
Red  
Major alarm present. Major alarms include:  
user-configured manor environmental inputs, DS1 short, DS1 open, DS1  
facility alarm, DS1 RAI, DS1 AIS, DS1 LOF, DS1 LOS, WAN fault,  
Ethernet fault and dead card alarms.  
Minor  
Status  
Off  
No minor alarms present  
Red  
Minor alarms present. Minor alarms include:  
user-configured minor environmental inputs, DS1 excessive line code  
violations.  
Off  
No power to system  
Green  
Application running, no detected system problems.  
Green Flashing  
Power-On Self Test (POST) successful. System booted. Loading  
Application.  
Green/Yellow  
Yellow  
Flashing alternate colors. Application Self Test in Process.  
Yellow while booting. If this stays a steady yellow the Power-On Self Test  
(POST) failed.  
Yellow Flashing Power-On Self Test (POST) In Process.  
Red  
System Failure  
18  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Web-Based Management  
Web-Based Management  
The web-based management interface allows you to control various system parameters. The interface  
is accessed through a web browser.  
To access the management console:  
NOTE: The following assumes that you have connected the PC to the LAN port of the Adit  
3104.  
1. Launch a web browser on your PC in the LAN to which the Adit 3104’s LAN port is connected.  
Note: If connection to the 3104 is to be through an Ethernet or T1 WAN, the remote admin  
WAN access must be enabled with the following command sequence:  
Command  
Description  
Username: admin  
Log into the system (username and password).  
Password: ********  
Adit 3104> enable  
Password: ********  
#configure terminal  
Enter the Privileged mode.  
Enter password for the Privileged mode.  
Enter the Configuration mode.  
Enable remote web admin.  
(config)# remote-admin web  
primary-port enable  
2. Type the Adit 3104’s IP address or name in the address bar.  
z Default IP address is http://192.168.1.1  
Note: to display the current IP address of the systems, use the following CLI command:  
#show interface ethernet 1 (LAN)  
#show interface ethernet 2 (Eth WAN)  
3. Login to the unit.  
Enter User Name and Password. Note: these setting should be changed from the default settings  
after the initial login.  
z Default user name is admin  
z Default password is admin 123  
NOTE: After a few minutes of inactivity, the session will automatically timeout and the  
operator will be required to log in to continue the session.  
WARNING! IF YOUR USER NAME AND PASSWORD ARE SET TO THE DEFAULT SETTING, IT IS  
RECOMMENDED THAT YOU MODIFY THEM FOR SECURITY PURPOSES.  
Adit 3104 - Release 1.6  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Setting up a CLI Connection  
Setting up a CLI Connection  
A CLI connection will require the LAN or WAN IP address of the unit. Note: If the WAN IP address  
is used, the remote admin WAN access must be enabled with the following command sequence:  
Command  
Description  
Username: admin  
Log into the system (username and password).  
Password: ********  
Adit 3104> enable  
Password: ********  
#configure terminal  
Enter the Privileged mode.  
Enter password for the Privileged mode.  
Enter the Configuration mode.  
Enable remote web admin.  
(config)# remote-admin web  
primary-port enable  
NOTE: For Adit 3104 CLI commands see the Adit 3000 CLI Reference Manual. This is a  
separate document and can be found on the CD that is provided with the product, or on the  
Carrier Access customer website.  
To connect with CLI, set up the connection:  
z If connecting via the Ethernet 100Base-TX connection, use a Telnet TCP/IP program to access  
the CLI. This requires an IP address of the unit.  
Note: to display the current IP address of the unit, use the ifconfig command.  
z If connecting via RS-232, the port settings should be set to:  
Bits per second: 115200  
Parity: None  
Data bits: 8  
Stop bits: 1  
Flow control: None  
z Set your Terminal Emulation to: VT100  
NOTE: When using Tera Term (Telnet program) TCP/IP, CLI commands will not be  
recognized until the following setup is completed.  
z In Tera Term go to Setup/Terminal  
z Set the New-line/Transmit value CR+LF  
20  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Log in  
Log in  
After successful connection, via telnet or HyperTerm, the user must login. Default Logins are:  
Login: admin  
Password: admin123  
After successful login the prompt will be displayed as follows:  
Adit 3104>  
NOTE: It is recommended that you change your password from the default.  
Adit 3104 - Release 1.6  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Key Enabled Software Features  
Key Enabled Software Features  
The Adit 3104 has additional features that are not provided on the base system. These features can be  
purchased with the product or added later as needed. These features are enabled via a Software Key  
(example: G.729). The number of keyed features may expand with the development of the product,  
therefore to see a list of current keyed features, or to purchase a key, contact Carrier Access Customer  
Service or Sales.  
To enter a software key, use the following CLI command:  
Syntax: (config)# key {key-code}  
Example: (config)# key cxusdfutkj3diosn412C  
NOTE: Keys may only be entered through the CLI (not through the GUI).  
The Key Enabled Software Features are displayed on the Advanced/Technical Information window.  
This information is also displayed with the following CLI command:  
Adit 3104> show version  
Application Version: 1.5.0.24  
Compilation Time: Thu Jun 14 2007 18:43:10  
FPGA Version: 2.00  
Board Version: 0 003-1129-0020  
IXP400 Software Release: 1_4 SQA4_1  
Voice Slot 1 : FXS Card Present: Rev 1.00 CLEI Code:IPU3AARBAA  
Voice Slot 2 : -- EMPTY --  
Voice Slot 3 : -- EMPTY --  
Vendor: Carrier Access  
CLEI Code: IPMP200JRA  
Product Features:  
VPN enabled.  
MGCP enabled.  
SIP enabled.  
22  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Basic Configuration  
Basic Configuration  
The following configuration is divided into logical sections, where each section configures an additional  
function. The first must be configured before the second and so forth, however, you may stop at any  
section and not add the following feature.  
NOTE: The order in which commands are entered can affect the successful provisioning of  
the Adit 3104.  
Setup Adit for access via Web-Browser  
The following steps will configure the Adit 3104 to allow access to the Web Browser for configuration,  
through one of the 4 10/100Base-T LAN connections.  
Note: for LAN access, no additional configuration is required to access the Adit using the web browser.  
To configure the WAN access:  
1. Connect to the CLI via the DB-9 RS-232. See Setting up a CLI Connection on page 20.  
2. Enable the remote admin WAN access with the following command sequence:  
Command  
Description  
Username: admin  
Log into the system (username and password).  
Password: ********  
Adit 3104> enable  
Password: ********  
#configure terminal  
Enter the Privileged mode.  
Enter password for the Privileged mode.  
Enter the Configuration mode.  
Enable remote web admin.  
(config)# remote-admin web  
primary-port enable  
Adit 3104 - Release 1.6  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quick Start  
Basic Configuration  
Restore Factory Defaults  
If the unit is not out-of-the-box, you may want to verify that the unit is set to defaults. Note: this will  
reset the IP address back to the default setting of 192.168.1.1.  
In the web-browser:  
z Select Advanced from the Navigation bar  
z Select Restore Defaults  
z Select OK to restore defaults  
24  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Basic Configuration  
Modify Default Admin User  
For security purposes it is recommended that the Administrator User be changed from the default  
settings.  
Modify the Administrator User in the web-browser:  
z Select Advanced from the Navigation bar  
z Select Users icon  
z Select Administrator, to open the profile.  
Adit 3104 - Release 1.6  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Basic Configuration  
z Modify the User information, and select OK to save. It is important to note that you need to  
have a minimum of one user with Administrative Privileges. For users with other access  
levels, add a New User.  
Note: For security purposes, the password should be changed.  
26  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Basic Configuration  
Configure Ethernet WAN Interface  
In the web-browser:  
1. Select Network Connections from the Navigation bar.  
2. It is recommended that you disable/delete the Serial1 port.  
3. Select (click) Ethernet 2 (WAN Ethernet) connection to configure.  
4. Select the Enable button, to configure the WAN Ethernet up (or in-service).  
5. Select the Settings button.  
Adit 3104 - Release 1.6  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Basic Configuration  
6. Set Internet Protocol to Obtain an IP Address Automatically, from the pulldown menu. This  
will enable the Adit 3104 as a DHCP Client. Leave the other fields to their default settings.  
7. Select Apply to apply the new settings.  
28  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Basic Configuration  
Configure Serial1 as WAN  
In the web-browser:  
1. Select Network Connections from the Navigation bar.  
2. Select Serial1.  
3. Select Settings button.  
4. Set Network to WAN.  
5. Select Apply to apply the new settings.  
Adit 3104 - Release 1.6  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Basic Configuration  
6. Select the Enable button.  
30  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Basic Configuration  
Configure the Adit 3104 as a SIP Line Gateway  
In the web-browser:  
1. Select Voice Over IP from the Navigation bar.  
2. Select Use SIP Proxy.  
3. Enter Softswitch IP Address, User name and Password.  
4. Select applicable Codecs.  
5. Select Apply to apply the new settings.  
Adit 3104 - Release 1.6  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start  
Basic Configuration  
6. Select the Phone Settings tab.  
7. Select the Action icon on line #1 to edit.  
32  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Basic Configuration  
8. Enter a telephone number in the User ID field and select OK.  
9. Repeat this step for each line you would like to have register with your Softswitch.  
Adit 3104 - Release 1.6  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start  
Basic Configuration  
34  
Adit 3104 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Breville Blender BLR50 User Manual
Brinkmann Gas Grill ProSeries 7751 User Manual
BRK electronic Fire Extinguisher FEBRA2 6 User Manual
Cal Spas Hot Tub LTR20091002 User Manual
Canon All in One Printer 2711B054AA User Manual
Canon Binoculars 10x42L IS WP User Manual
Carrier Air Compressor 06D User Manual
Carrier Heat Pump 38YCX User Manual
Casio Watch 1940 1 User Manual
Cisco Systems IP Phone OL 12997 01 User Manual