Carrier Access Network Card Adit 3500 User Manual

Adit 3500  
QUICK START GUIDE  
Part Number: 002-0250-0010  
Product Release: 1.6  
September 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Unpacking and Inspection  
Unpacking and Inspection  
WARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES.  
1. Inspect containers for damage during shipment. Report any damage to the freight carrier for  
possible insurance claims.  
2. Compare packing list with office records. Report any discrepancies to the office.  
3. Open shipping containers, be careful not to damage contents.  
4. Inspect contents and report any damage.  
5. If equipment must be returned for any reason, carefully repack equipment in the original  
shipping container with original packing materials if possible.  
6. If equipment is to be installed later, replace equipment in original shipping container and store  
in a safe place until ready to install.  
Electrostatic Discharge (ESD) Precautions  
ESD can damage processors, circuit cards, and other electronic components. Always  
observe the following precautions before installing a system component.  
1. Do not remove a component from its protective packaging until ready to  
install it.  
2. Wear a wrist grounding strap and attach it to a metal part of the system unit  
before handling components. If a wrist strap is not available, maintain contact with the system  
unit throughout any procedure requiring ESD protection.  
WARNING! INTEGRATED CIRCUITS (ICS) ARE EXTREMELY SUSCEPTIBLE TO ELECTROSTATIC  
DISCHARGE. UNLESS YOU ARE A QUALIFIED SERVICE TECHNICIAN WHO USES TOOLS AND  
TECHNIQUES THAT CONFORM TO ACCEPTED INDUSTRY PRACTICES, DO NOT HANDLE ICS.  
The ESD warning label appears on packages and storage bags that contain static-sensitive products and  
components.  
4
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quick Start Guide  
Installation Environment  
Installation Environment  
The environment in which you are installing the Adit 3000 must meet the following conditions:  
z Operating temperature range: 32° to 104° F (0° to 40° C)  
z Storage temperature range: -40° to 158° F (-40° to 70° C)  
z Maximum operating altitude: 10,000 ft. (3,048 m)  
z Maximum non-operating altitude: 40,000 ft. (12,192 m)  
z Relative humidity (non-condensing) range: 0 to 95%  
WARNING! THE ADIT 3000 IS DESIGNED FOR WALL AND RACK MOUNTING ONLY. IT IS NOT  
DESIGNED FOR DESKTOP USE.  
User Safety  
CAUTION! WHEN USING YOUR TELEPHONE EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD  
ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PERSONS,  
INCLUDING THE FOLLOWING:  
z Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or  
laundry tub, in a wet basement or near a swimming pool.  
z Avoid using a telephone (other than a cordless type) during an electrical storm. There may be  
a remote risk of electric shock from lightning.  
z Do not use the telephone to report a gas leak in the vicinity of the leak.  
z Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a  
fire. They may explode. Check with local codes for possible special disposal instructions.  
z Refer to the installation section of this manual for a safe and proper installation procedure. All  
wiring external to this equipment should follow the current provision of the National Electrical  
Code.  
Adit 3500 - Release 1.6  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quick Start Guide  
Installation  
Installation  
The following are instructions for a compliant installation of the Adit 3500. Please note the following  
warnings, before installing the unit.  
For wall and rack mount instructions, use the links listed below to the appropriate section:  
WARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES. SEE  
WARNING! THE ADIT 3500 DS1 NETWORK INTERFACE PORTS ARE CERTIFIED WITH ACTA,  
INDUSTRY CANADA AND UL FOR DIRECT CONNECTION TO PUBLIC DIGITAL NETWORKS. TO PREVENT  
EQUIPMENT DAMAGE FROM LIGHTNING SURGES, AC INDUCTION OR POWER LINE CONTACT, UTILIZE  
LISTED PRIMARY PROTECTORS AT THE BUILDING ENTRANCE WITH MINIMUM 4 OHM CURRENT-  
LIMITING AND MAXIMUM 600V IMPULSE BREAKDOWN AT 1000V/USEC. THE ADIT 3500 DS1 PORTS  
COME EQUIPPED WITH SECONDARY OVERVOLTAGE AND OVERCURRENT PROTECTION. THE  
INSTALLATION IS REQUIRED TO MEET LOCAL OR NATIONAL ELECTRIC CODES FOR COMMUNICATION  
SYSTEMS.  
WARNING! THE ADIT 3500 FXS INTERFACE PORTS ARE INTENDED TO SERVE INDOOR  
COMMUNICATION CONDUCTORS ONLY. OVERVOLTAGE AND OVERCURRENT PROTECTION IS  
PROVIDED TO PREVENT EQUIPMENT DAMAGE FROM LIGHTNING SURGES OR AC POWER LINE  
CONTACT INSIDE BUILDINGS. THE FXS PORTS ARE NOT SUITABLE FOR CONNECTION TO EXPOSED  
OUTDOOR COMMUNICATION CONDUCTORS.  
6
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Installation  
Compliant Installation  
NOTE: It is important the DS1/E1 Network Interface Cables are secured separately from the  
power and Signal Cables.  
1. Inspect the unit.  
2. Mount the unit.  
z Wall mounting installation, see Wall Mounting on page 9.  
z Wall mounting with Battery Backup Unit, see Battery Backup on page 12.  
z Rack mounting installation, see Rack Mounting on page 10.  
3. Ground the unit.  
WARNING! THE ADIT 3500 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE  
PROTECTION OF USERS AND SERVICE PERSONNEL. REFER TO Grounding the Unit ON PAGE 3 FOR  
DETAILED INSTRUCTIONS.  
4. Connect DS1 (T1), and Ethernet connections as needed.  
5. Connect RS-232 connector and connect via HyperTerm on your PC.  
Note: With this running before power is enabled, you can monitor the boot process.  
6. Attach PBX and phone line cables.  
7. Connect Power to the unit.  
8. Monitor the boot process on your PC, when complete the status light should be green.  
9. For any software enabled features, enter the key command. See the key command in the Adit  
3000 CLI Reference Manual, for detailed information.  
10. To verify use the show version command.  
11. To provision the unit. See Web-Based Management on page 23, for detailed instructions.  
Adit 3500 - Release 1.6  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Installation  
Ferrite Beads  
The following ferrite bead is required on the Adit 3500 configurations that do not have the FXS 4  
channel option. The ferrite bead will enable the Adit to be compliant with EMI standards FCC Part 15  
and ICES-003 Class A.  
Ferrite beads shipped with Adit chassis:  
Ferrite Provided  
Part Number  
Intended For  
1 large  
P/N 010-0051  
Power cable, which requires a loop through the bead (see  
drawing).  
Back of  
Adit 3500  
Ferrite  
Bead  
Loop  
through  
Ferrite  
Bead  
12V Power  
Cord  
For additional information on Ferrite beads and their installation on the Adit 3500, please contact  
Carrier Access Customer Support at (800) 786-9929.  
8
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Installation  
Wall Mounting  
Before beginning the mounting process, verify that the installation area is a stable environment, clean  
and free from extremes of temperature, shock, vibration and EMI.  
Mounting Bracket  
Back of unit  
Front of unit  
Leave adequate space  
at the front/back for  
access to connectors  
The Adit 3000 is delivered with mounting brackets that can easily be attached for quick and easy wall  
mounting, as shown in the illustration above.  
To install the unit to the wall:  
1. Attach the wall mount brackets to the Adit 3000, with wall attachment flange pointing away  
from the unit, as shown above. Attach with 4 screws provided (2 for each bracket).  
2. Mount the unit to the wall using appropriate mounting screws (not included).  
Note: it is acceptable to mount on drywall with suitable anchor-type mounting screws.  
NOTE: The Adit 3000 must be mounted with the brackets on the top and bottom, as  
shown above.  
Adit 3500 - Release 1.6  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Installation  
Rack Mounting  
This is an Optional Feature.  
NOTE: Rack mounting kits are available for both 19 and 23 inch racks. 1 Rack Unit (RU) of spacing  
is required above the Adit 3000 in the Rack Mount Unit.  
To rack mount the Adit 3000, follow the instructions below:  
1. Attach bracket ears to Rack Mounting Tray using four #10-32 x 1/4" screws on each side. The  
Mounting Ears can be used for both a 19 or 23 inch rack. The drawing below shows a top view  
of the 2 versions.  
Mounting Ear  
Rack Mounting Tray  
23 in rack  
Rack Mount Tray  
Front  
screws  
screws  
Mounting Ear  
Mounting Ear  
19 in rack  
Rack Mount Tray  
screws  
screws  
Front  
Mounting Ear  
Mounting Ear  
2. Attach the Rack Mounting Tray assembly (with mounting ears attached) to rack, using four  
#10-32 x 1/4” screws (two on each mounting ear).  
3. Remove wall mount and screws, if attached, from Adit 3500 unit.  
Note: Adit 3500 and wall mounting bracket are not assembled from the factory.  
10  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Installation  
4. Place the Adit 3000 on the Tray Slide and attach with the 4 screws removed in step 2.  
screws  
screws  
Tray Slide  
5. Slide the assembled piece (Adit 3000 and Tray Slide) onto the installed Rack Mounting Tray.  
6. Secure the Tray Slide to the Rack Mounting Tray with the attached screws on the Tray Slide.  
NOTE: The mounting brackets are designed to not allow units to be mounted closer than  
recommended.  
Adit 3500 - Release 1.6  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Installation  
Battery Backup  
This is an Optional Feature.  
The Adit 3500 Battery Backup is  
designed specifically for the Adit 3500.  
The battery backup unit is a single 12V  
sealed lead-acid battery in a metal  
enclosure designed for wall mounting.  
Installation  
There are two possible configurations to wall mount the Adit 3500 and the Battery Backup.  
NOTE: It is recommended that the BBU be mounted to a wooden backboard using (4) #6  
screws, or to drywall using (4) #6 screws with anchors. These screws are not provided.  
1. Battery Backup attached to wall, with Adit 3500 mounted on the Battery Backup  
2. Adit 3500 and Battery Backup attached to wall.  
Option 1  
view from side  
Option 2  
Adit 3500  
Wall  
Battery Backup  
12  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Installation  
#1 Adit 3500 mounted on top of the Battery Backup  
This method will use a minimal amount of wall space. Note: This installation will require a  
minimum wall space of space of: 9" (H) x 14" (W) x 5" (D).  
1. Mount the Battery Backup to the wall with  
(4) #6 x 1 coarse thread screws Note:  
Screws are not provided  
z Mark the location for the top 2 screws  
(using BBU mounting keyhole as a guide)  
z Screw these 2 screws into the wall at  
marked locations.  
Note: do not screw tight to the wall, leave  
1/4" to allow BBU mounting keyholes to  
slip over screw head.  
z Attach the BBU by slipping the screw  
heads through the keyhole slots of the  
BBU, and let unit drop slightly to allow  
screwheads to enter top of the keyhole.  
z Screw bottom 2 screws into mounting  
holes at the bottom of the unit.  
z Tighten all screws to the wall.  
2. Attach Adit 3500 Wall Mounting  
Brackets to the BBU. Note: Brackets  
are provided with the Adit 3500 unit.  
z Each bracket is attached to the outer  
facing side of the BBU.  
Note the bracket orientation in the  
graphic.  
3. Insert Adit 3500 Power cord through  
the holder on the right. This supports  
Power Cord  
Holder  
the weight of the adapter portion of  
the power cord.  
Wall Brackets  
z The connector to the wall runs out  
the bottom, while the connector to  
the Adit 3500 will run out of the top.  
Adit 3500 - Release 1.6  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Installation  
4. Attach Adit 3500 to the assembled  
Second bracket  
here  
BBU and brackets.  
z Each bracket attaches to the side of  
the Adit 3500.  
Note the orientation of the Adit in  
the graphic.  
5. Attach power cords.  
z Connect cord from BBU to the Adit  
3500 (2 pin connector).  
z Connect 12V power cord to Adit  
Screws into  
side of Adit  
3500.  
Front of Adit  
14  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Installation  
#2 Adit 3500 and Battery Backup mounted to the wall  
This method requires a more wall space. Note: This installation will require a minimum of wall  
space of: 17" (H) x 14" (W) x 2.5" (D).  
Adit 3500  
Back  
Front  
Battery Cable  
Holds AC Adapter  
portion of power  
cord  
Battery Backup  
1. Mount the Battery Backup to the wall with (4) #6 screws, by:  
z Mark the location of the left-side 2 screws (using the BBU mounting keyhole as a guide).  
Note: this installation of the BBU is oriented with the mounting keyholes to the left side.  
z Screw these 2 screws into the wall at marked locations. Note: do not screw tight to the wall,  
leave 1/4" to allow BBU mounting keyholes to slip over screw head.  
z Attach the BBU by slipping the screw heads through the keyhole slots at the left of the  
BBU, and slide unit to the right to allow screwheads to enter the narrow end of the keyhole.  
z Screw the second set of 2 screws into mounting holes on the right of the unit.  
z Tighten all screws to the wall.  
2. Insert Adit 3500 Power cord through the holder on the top of the BBU. This supports the  
weight of the adapter portion of the power cord.  
3. Attach Adit 3500 to the wall following the instructions, Wall Mounting on page 9.  
Attaching the Adit 3500 to the wall above the BBU.  
Note: there is a distance limit between the Adit and the BBU (note the length of the battery  
cable to the Adit).  
4. Attach power cords.  
z Connect cord from BBU to the Adit 3500 (2 pin connector).  
z Connect 12V power cord to Adit 3500.  
Adit 3500 - Release 1.6  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Chassis Overview  
Adit 3500 Battery Backup Power Connector  
The following cable, is hard wired to the Adit 3500 Battery Backup and connects the Adit 3500.  
Definition  
12V (+)  
12V (-)  
Pinout  
Wire  
Red  
Black  
Chassis Overview  
The following illustrations show all connectors on the Adit 3500.  
Front  
Alarm  
Status  
Reset  
(4) Analog (FXS) connectors  
(4) DS1/E1  
(E1 Future)  
(2) 10/100Base-T  
Back  
RS-232  
Battery  
Ground  
Management  
Power  
Port  
16  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Interface Connectors  
Interface Connectors  
The following are the Adit 3500 interface connectors:  
Note: The following is dependant upon how the system (hardware) is configured. Systems can be  
ordered with/without FXS, and can have from 1-4 DS1 ports.  
Front of Adit  
z 4 DS1 Ports (used for DS1 WAN and/or PRI/CAS trunks) (RJ-45C connector).  
- (1) T1-based WAN - uses 1 or 2 DS1 ports  
- (1) PRI/CAS group - uses 1 or 2 DS1 ports  
z (1) 10/100Base-TX WAN port (RJ-45 connector)  
z (1) 10/100Base-TX LAN port (RJ-45 connector)  
z 4 FXS (RJ-11 connector)  
Back of Adit  
z RS-232 craft port connector for local management  
z Power input connector  
z Battery input connector  
z Ground connector  
Grounding the Unit  
WARNING! THE ADIT 3500 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE  
PROTECTION OF USERS AND SERVICE PERSONNEL.  
Chassis ground is located on the back of the unit.  
To ground the unit:  
1. Connect a minimum 14 AWG ground  
wire with a #8 ring tongue terminal (not  
included) to the chassis ground on the  
back of the unit. Secure with the 8-32  
screw and lock washer provided.  
Chassis  
Ground  
2. Connect the opposite end of the ground  
wire to a suitable earth grounding point  
such as a building grounding electrode,  
metal water pipe, or metal building  
structure that is in compliance with article 250 of NEC.  
Adit 3500 - Release 1.6  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Interface Connectors  
12 VAC Power Connection  
The Adit 3500 is powered by a 12 VAC Power Converter, which provides 12 VDC to the unit.  
Item  
Specification  
AC100V-240V  
AC90V-255V  
50-60 Hz  
Rate input voltage  
Input  
Vibration input voltage range  
Frequency Rated  
Frequency Vibration  
Input rated current  
47-63Hz  
15A max. at 115VAC cool start  
30A max. at 230VAC cool start  
Leakage current  
Efficiency  
0.25mA  
70% Min.  
Output voltage  
13.5VDC  
Output  
Output max. current  
Output min. current  
Line regulation  
2.2A+150mA (V out = 9VDC-13VDC)  
0A (V out = 14VDC)  
+1%  
Load regulation  
Short circuit protection  
+5%  
Output shut down auto restart  
Battery Connection  
The Battery connector on the Adit 3500 is a 2 pin connector provided specifically for the  
Battery Backup option. See Battery Backup on page 10 for additional information.  
18  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Interface Connectors  
DS1/E1 Connection Ports  
1
8
Each DS1/E1 connection port is equipped with a standard RJ-48C (female) on the  
Adit 3500 unit. Note: E1 will be available in a future release.  
The pinouts are as follows:  
DS1/E1 RJ-48C  
The pinouts are as follows:  
Pin  
1
Name  
Description  
Receive Ring  
Receive Tip  
N/C  
Receive from DS1 network  
Receive from DS1 network  
Not connected  
2
3
4
Transmit Ring  
Transmit Tip  
N/C  
To DS1 network  
5
To DS1 network  
6 -8  
Not connected  
The LEDs are as follows (left LED only):  
State  
Description  
Off line  
Off  
Green  
Normal  
Red  
Loss of Signal (LOS)  
Yellow  
Bipolar Violation (BPV)  
Flashing Green  
Flashing Yellow  
Flashing Red (Slow)  
Flashing Red (Fast)  
Loopback active  
Yellow Alarm (Remote Alarm Indication)  
Loss of Frame (LOF) or Alarm Indication Signal (AIS)  
Self-test Failure  
Adit 3500 - Release 1.6  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Interface Connectors  
10/100Base-TX Ethernet  
1
8
The 10/100Base-TX Ethernet (female) ports provide connectivity for Router WAN  
and/or LAN ports and for management connection via Telnet and/or SNMP to a  
Network Management System.  
Ethernet (RJ-45)  
The pinouts are as follows:  
Note: This is a hub pinout, you will need a straight cable to connect to a PC.  
Pin  
1
Name  
Description  
Receive +  
Receive -  
Transmit +  
N/C  
Receive from network  
Receive from network  
Transmit to network  
Not connected  
2
3
4-5  
6
Transmit -  
N/C  
Transmit to network  
Not connected  
7-8  
The LEDs are as follows:  
LED  
State  
Description  
Left LED  
The left LED shall show Link Status.  
Off  
Link Down  
Green  
Link Up  
Flashing Green  
Yellow  
Traffic on Link  
Collision status  
Right LED  
The right LED shall indicate Link Speed.  
Off  
10 Mbit/sec, down or not connected  
100 Mbit/sec  
Green  
20  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Reset Button  
RS-232 Craft Port (Female DB-9)  
The RS-232 craft port connector (female) is for connection to an external PC or Hayes-compatible  
modem for local or remote configuration, management, and performance monitoring using the Adit  
3500 Command Line Interface (CLI).  
The RS-232 craft port connects via a female DB-9 connector on the Adit  
3500.  
1
5
6
9
The pinouts are as follows:  
Pin  
1
Direction  
Outbound  
Outbound  
Inbound  
Inbound  
N/A  
Description  
Carrier Detect  
Receive Data  
2
3
Transmit Data  
Data Terminal Ready  
Signal Ground  
Data Set Ready  
Request to Send  
Clear to Send  
4
5
6
Outbound  
Inbound  
Outbound  
N/C  
7
8
9
Not connected  
RJ-11 Connector  
There are four RJ-11 (female) connectors for the FXS ports.  
The pinouts are as follows:  
6
1
Pin  
1 - 2  
3
Name  
N/C  
R
Description  
Not connected  
Ring  
4
T
Tip  
5 - 6  
N/C  
Not connected  
Reset Button  
The system can be reset by pressing the reset button located on the front panel.  
Adit 3500 - Release 1.6  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Alarm/Status LEDs  
Alarm/Status LEDs  
LED  
State  
Description  
Critical Off  
No critical alarms present  
Red  
Critical alarms present. Critical alarms include:  
user-configured manor environmental inputs.  
Major  
Off  
No major alarms present  
Red  
Major alarm present. Major alarms include:  
user-configured manor environmental inputs, DS1 short, DS1 open, DS1  
facility alarm, DS1 RAI, DS1 AIS, DS1 LOF, DS1 LOS, WAN fault,  
Ethernet fault and dead card alarms.  
Minor  
Status  
Off  
No minor alarms present  
Red  
Minor alarms present. Minor alarms include:  
user-configured manor environmental inputs, DS1 excessive line code  
violations.  
Off  
No power to system  
Green  
Application running, no detected system problems.  
Power-On Self Test (POST) successful. System booted. Loading Application.  
Flashing alternate colors. Application Self Test in Process.  
Green Flashing  
Green/Yellow  
Yellow  
Yellow while booting. If this stays a steady yellow the Power-On Self Test  
(POST) failed.  
Yellow Flashing Power-On Self Test (POST) In Process.  
Red  
System Failure  
22  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Web-Based Management  
Web-Based Management  
The web-based management interface allows you to control various system parameters. The interface  
is accessed through a web browser.  
To access the management console:  
NOTE: The following assumes that you have connected the PC to the LAN port of the Adit  
3500.  
1. Launch a web browser on your PC in the LAN to which the Adit 3500’s LAN port is connected.  
Note: If connection to the 3500 is to be through an Ethernet or T1 WAN, the remote admin  
WAN access must be enabled with the following command sequence:  
Command  
Description  
Username: admin  
Log into the system (username and password).  
Password: ********  
Adit 3500> enable  
Password: ********  
#configure terminal  
Enter the Privileged mode.  
Enter password for the Privileged mode.  
Enter the Configuration mode.  
Enable remote web admin.  
(config)# remote-admin web  
primary-port enable  
2. Type the Adit 3500’s IP address or name in the address bar.  
z Default IP address is http://192.168.1.1  
Note: to display the current IP address of the systems, use the following CLI command:  
#show interface ethernet 1 (LAN)  
#show interface ethernet 2 (Eth WAN)  
3. Login to the unit.  
Enter User Name and Password. Note: these setting should be changed from the default settings  
after the initial login.  
z Default user name is admin  
z Default password is admin 123  
NOTE: After a few minutes of inactivity, the session will automatically timeout and the  
operator will be required to log in to continue the session.  
WARNING! IF YOUR USER NAME AND PASSWORD ARE SET TO THE DEFAULT SETTING, IT IS  
RECOMMENDED THAT YOU MODIFY THEM FOR SECURITY PURPOSES.  
Adit 3500 - Release 1.6  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Setting up a CLI Connection  
Setting up a CLI Connection  
A CLI connection will require the LAN or WAN IP address of the unit. Note: If the WAN IP address  
is used, the remote admin WAN access must be enabled with the following command sequence:  
Command  
Description  
Username: admin  
Log into the system (username and password).  
Password: ********  
Adit 3500> enable  
Password: ********  
#configure terminal  
Enter the Privileged mode.  
Enter password for the Privileged mode.  
Enter the Configuration mode.  
Enable remote web admin.  
(config)# remote-admin web primary-  
port enable  
NOTE: For Adit 3500 CLI commands see the Adit 3000 CLI Reference Manual. This is a  
separate document and can be found on the CD that is provided with the product, or on the  
Carrier Access customer website.  
To connect with CLI, set up the connection:  
z If connecting via the Ethernet 100Base-TX connection, use a Telnet TCP/IP program to access  
the CLI. This requires an IP address of the unit.  
Note: to display the current IP address of the unit, use the ifconfig command.  
z If connecting via RS-232, the port settings should be set to:  
Bits per second: 115200  
Parity: None  
Data bits: 8  
Stop bits: 1  
Flow control: None  
z Set your Terminal Emulation to: VT100  
NOTE: When using Tera Term (Telnet program) TCP/IP, CLI commands will not be  
recognized until the following setup is completed.  
z In Tera Term go to Setup/Terminal  
z Set the New-line/Transmit value CR+LF  
24  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Log in  
Log in  
After successful connection, via telnet or HyperTerm, the user must login. Default Logins are:  
Login: admin  
Password: admin123  
After successful login the prompt will be displayed as follows:  
Adit 3500>  
NOTE: It is recommended that you change your password from the default.  
Key Enabled Software Features  
The Adit 3500 has additional features that are not provided on the base system. These features can be  
purchased with the product or added later as needed. These features are enabled via a Software Key  
(example: G.729). The number of keyed features may expand with the development of the product,  
therefore to see a list of current keyed features, or to purchase a key, contact Carrier Access Customer  
Service or Sales.  
To enter a software key, use the following CLI command:  
Syntax: (config)# key key-code  
Example: (config)# key cxusdfutkj3diosn412C  
NOTE: Keys may only be entered through the CLI (not through the GUI).  
The Key Enabled Software Features are displayed on the Advanced/Technical Information window.  
Adit 3500 - Release 1.6  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quick Start Guide  
Key Enabled Software Features  
This information is also displayed with the following CLI command:  
Adit 3500> show version  
Application Version: 1.5.0  
Compilation Time: Thu Jun 14 2007 18:07:22  
FPGA Version: 1.00  
Board Version: 5 003-1215-0300  
IXP400 Software Release: 1_4 SQA4_1  
MSP:  
82530 - 60 channels  
Image File Name: TGW_v5_05.axf  
API Version  
: 2.1.0  
Source IP Addr : 192.168.1.1  
Voice Slot 1 : FXS Card Present: Rev 3.00  
Vendor: Carrier Access  
CLEI Code: IPMHX00LRA  
Product Features:  
SIP enabled.  
G729A enabled.  
26  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
Basic Configuration  
The following configuration is divided into logical sections, where each section configures an additional  
function. The first must be configured before the second and so forth, however, you may stop at any  
section and not add the following feature.  
NOTE: The order in which commands are entered can affect the successful provisioning of  
the Adit 3500.  
Setup Adit 3500 for access via Web-Browser  
The following steps will configure the Adit 3500 to allow access to the Web Browser for configuration,  
through the LAN (1) or WAN (2) 10/100Base-T Ethernet connections.  
Note: for LAN access, no additional configuration is required to access the Adit using the web browser.  
To configure the WAN access:  
1. Connect to the CLI via the DB-9 RS-232. See Setting up a CLI Connection on page 24.  
2. Enable the remote admin WAN access with the following command sequence:  
Command  
Description  
Username: admin  
Log into the system (username and password).  
Password: ********  
Adit 3500> enable  
Password: ********  
#configure terminal  
Enter the Privileged mode.  
Enter password for the Privileged mode.  
Enter the Configuration mode.  
Enable remote web admin.  
(config)# remote-admin web  
primary-port enable  
Adit 3500 - Release 1.6  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quick Start Guide  
Basic Configuration  
Restore Factory Defaults  
If the unit is not out-of-the-box, you may want to verify that the unit is set to defaults.  
Note: this will reset the IP address back to the default setting of 192.168.1.1.  
In the web-browser:  
z Select Advanced from the Navigation bar  
z Select Restore Defaults  
z Select OK to restore defaults  
28  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Basic Configuration  
Modify Default Admin User  
For security purposes it is recommended that the Administrator User be changed from the default  
settings.  
Modify the Administrator User in the web-browser:  
z Select Advanced from the Navigation bar  
z Select Users icon  
z Select Administrator, to open the profile.  
Adit 3500 - Release 1.6  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Basic Configuration  
z Modify the User information, and select OK to save. It is important to note that you need to  
have a minimum of one user with Administrative Privileges. For users with other access  
levels, use the New User to add additional users on the system.  
Note: For security purposes, the password should be changed from the default setting.  
z You will be required to login again, if you have modified the User Profile that you are logged  
in with.  
30  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
Configure WAN Interface for Internet Connectivity  
There are options to this WAN configuration. This is the connection to the end user’s internet provider.  
It can be the following:  
Single T1 (PPP)  
To configure a single T1 utilizing PPP:  
1. Select Network Connections from the Navigation bar.  
2. Select (click) a T1 Interface (from T1 1 - T1 4) to configure, T1 1 is recommended.  
Note: Using T1 1 and the preconfigured Serial 1 makes this configuration very simple. If you  
use T1 2-T1 4, you will need to delete the preconfigured Serial 1 and make a New Connection  
(Serial 1) based on the T1 2-T1 4 that you selected.  
Adit 3500 - Release 1.6  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quick Start Guide  
Basic Configuration  
3. Select the Settings button.  
4. Set the proper Framing Type and Line Coding.  
5. Select OK to apply the new settings and exit this window.  
6. Select OK again to return to the Network Connections window.  
32  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
7. Select (click) the Serial 1 connection.  
8. Select the Settings button.  
Adit 3500 - Release 1.6  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
9. Set the following on the Configure Serial 1 window:  
- Network Type to WAN (this is the default setting)  
- PPP Authentication to your required preferences  
10. Select OK to apply the new settings and exit this window.  
11. Select OK again to return to the Network Connections window.  
34  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
Multiple T1s (Multilink)  
To configure Multiple T1s utilizing Multilink PPP:  
1. Select Network Connections from the Navigation bar.  
2. Select (click) a T1 Interface (from T1 1 - T1 4) to configure.  
3. Select the Settings button.  
Adit 3500 - Release 1.6  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Basic Configuration  
4. Set the proper Framing Type and Line Coding.  
5. Select OK to apply the new settings and exit this window.  
6. Select OK again to return to the Network Connections window.  
7. Repeat steps #1-6 for additional T1s required for the ML-PPP  
8. Select (click) the delete icon associated with the Serial 1 connection.  
Select OK to confirm the deletion of this connection.  
36  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
9. Select (click) New Connection to create the ML-PPP connection.  
10. Select the Multilink Point-to-Point Protocol over DS0 (Multilink), and select Next.  
Adit 3500 - Release 1.6  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
11. Enter User Name and Password.  
12. Select the T1s for this Multilink and the channel ranges.  
13. Select Next.  
14. A summary of the Multilink connection will be displayed. If correct, select Finish.  
38  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
15. The new Multilink connection will display on the Network Connections window.  
16. Select (click) the Multilink 1 connection.  
17. Select the Settings button.  
Adit 3500 - Release 1.6  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
18. Set the following on the Configure Multilink 1 window:  
- Network Type to WAN (this is the default setting)  
- PPP Authentication to your required preferences  
19. Select OK to apply the new settings and exit this window.  
20. Select OK again to return to the Network Connections window.  
40  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
Ethernet WAN  
To configure the WAN utilizing Ethernet feed:  
1. Select Network Connections from the Navigation bar.  
2. Select (click) the delete icon associated with the Serial 1 connection.  
Select OK to confirm the deletion of this connection.  
3. Select (click) the Ethernet 2 (WAN Ethernet) connection to configure.  
Adit 3500 - Release 1.6  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Basic Configuration  
4. Select the Enable button, to configure the WAN Ethernet up (or in-service).  
5. Select the Settings button.  
6. Set Network type to WAN.  
7. Set Internet Protocol option (method of IP address assignment).  
8. Select OK to apply the new settings and exit this window.  
9. Select OK again to return to the Network Connections window.  
42  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
Configure the Adit 3500 as a SIP Gateway  
1. Select Voice Over IP from the Navigation bar.  
Adit 3500 - Release 1.6  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quick Start Guide  
Basic Configuration  
2. On the IP Telephony tab, under Proxy Servers:  
- Set Proxy Type to Generic/custom (BroadSoft or Sylantro). Example: BroadSoft  
- Select Use SIP Proxy and enter SIP Proxy IP address  
- Select supported Codecs  
3. Select Apply to save the new settings.  
4. Select the Advanced button.  
44  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
5. Modify any advanced VoIP settings as needed and select Apply.  
6. Select OK to exit window.  
Adit 3500 - Release 1.6  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
7. If using the FXS ports, select the Phone Settings tab.  
8. Select the Action icon on line #1 to edit.  
46  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
9. Enter the Phone Number in the User ID field.  
10. Enter Authentication information as needed.  
11. Select OK to apply and exit this window.  
12. Select OK to acknowledge that with these changes, active calls will be dropped.  
13. Repeat this step for each FXS Line.  
Adit 3500 - Release 1.6  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
14. The current User ID of the FXS lines will display.  
15. Select the Line Monitoring tab. This window displays the SIP status of the FXS ports.  
Note: When a telephone port is successfully registered the Registration Status column displays  
"Registered" in green."  
16. Select the Trunk Settings tab.  
17. Select (click) on the trunk to configure.  
18. Set the Trunk Signaling type to PRI or CAS.  
48  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
19. Set the Signaling Type.  
20. Select New Entry to assign numbers to your PRI interface(s).  
Adit 3500 - Release 1.6  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
21. Enter the phone number range for numbers to be routed to the trunk interface for incoming  
SIP calls, on the Call Destination window. Use Strip and Prefix entries to translate the incoming  
destination number from SIP to the destination number to be sent to the PRI/CAS interface.  
22. Select OK to save and exit this window.  
Note: this information will display at the bottom of the Trunk Settings window.  
23. Select OK again to return to the Voice Over IP window.  
50  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
24. Select the Trunk Monitoring tab to view the status of any calls on the PRI.  
Adit 3500 - Release 1.6  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start Guide  
Basic Configuration  
52  
Adit 3500 - Release 1.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker Convection Oven EF2750 User Manual
Blue Rhino Charcoal Grill CBT817L User Manual
Blue Rhino Outdoor Fireplace WAD794SPA User Manual
Boss Audio Systems Stereo System BV7320 User Manual
Breville Water Dispenser BWC200 User Manual
Briggs Stratton Switch 01813 1 User Manual
Bushnell Watch 70 0002 User Manual
Canon Projector project monitoring software User Manual
Chamberlain Garage Door Opener WD952KD User Manual
Cisco Systems IP Phone OL 14625 01 User Manual