030212 (2.5 kW)
030213 (2.8 kW)
Owner’s Manual
CAUTION
Before using this product, read this
manual and follow all Safety Rules and
Operating Instructions.
Questions?
Help is just a moment away!
Find your Briggs and Stratton distributor
or contact your local Briggs and Stratton dealer.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON,WISCONSIN, U.S.A.
Manual No. 196978GS
Revision 0 (04/22/2005)
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY RULES
WARNING
WARNING
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Petrol and its vapors are extremely flammable
and explosive.
Breathing carbon monoxide will cause nausea,
fainting or death.
Fire or explosion can cause severe burns or
death.
• Operate generator ONLY outdoors.
WHEN ADDING OR DRAINING PETROL
• Turn generator OFF and let it cool at least 2 minutes
before removing petrol cap. Loosen cap slowly to relieve
pressure in tank.
• Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes or other openings.
• DO NOT operate generator inside any building or
enclosure, including the generator compartment of a
recreational vehicle (RV).
• Fill or drain petrol tank outdoors.
• DO NOT overfill tank.Allow space for petrol expansion.
• Keep petrol away from sparks, open flames, pilot lights, heat,
and other ignition sources.
WARNING
Generator produces powerful voltage.
• DO NOT light a cigarette or smoke.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
WHEN STARTING EQUIPMENT
• Ensure spark plug, muffler, petrol cap and air cleaner are in
place.
• When using generator for backup power, notify utility
company. Use approved transfer equipment to isolate
generator from electric utility.
• Use a ground fault circuit interrupter (GFCI) in any damp
or highly conductive area, such as metal decking or steel
work.
• DO NOT touch bare wires or receptacles.
• DO NOT use generator with electrical cords which are
worn, frayed, bare or otherwise damaged.
• DO NOT crank engine with spark plug removed.
• If petrol spills, wait until it evaporates before starting
engine.
WHEN OPERATING EQUIPMENT
• Do not tip engine or equipment at angle which causes
petrol to spill.
• This generator is not for use in mobile equipment or
marine applications.
WHEN TRANSPORTING OR REPAIRING
EQUIPMENT
• Transport/repair with petrol tank EMPTY or with petrol
shutoff valve OFF.
• DO NOT operate generator in the rain.
• DO NOT handle generator or electrical cords while standing
in water, while barefoot, or while hands or feet are wet.
• DO NOT allow unqualified persons or children to operate
or service generator.
• Disconnect spark plug wire.
WHEN STORING PETROL OR EQUIPMENT WITH
PETROL IN TANK
• Store away from furnaces, stoves, water heaters, clothes
dryers or other appliances that have pilot light or other
ignition source because they can ignite petrol vapors.
WARNING
• This generator must not be used on marine applications.
• Using this generator in marine applications could result in
bodily injury and/or property damage.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY RULES
CAUTION
Excessively high operating speeds increase risk of
injury and damage to generator.
WARNING
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Excessively low speeds impose a heavy load.
Broken bones, fractures, bruises or sprains
could result.
• DO NOT tamper with governed speed. Generator supplies
correct rated frequency and voltage when running at
governed speed.
• When starting engine, pull cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
• NEVER start or stop engine with electrical devices plugged
in and turned on.
• DO NOT modify generator in any way.
CAUTION
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
WARNING
Unintentional sparking can result in fire or
electric shock.
• See “Don’t Overload Generator”.
• Start generator and let engine stabilize before connecting
electrical loads.
• Connect electrical loads in OFF position, then turn ON for
operation.
WHEN ADJUSTING OR MAKING REPAIRSTO
YOUR GENERATOR
• Disconnect the spark plug wire from the spark plug and
place the wire where it cannot contact spark plug.
• Turn electrical loads OFF and disconnect from generator
before stopping generator.
WHENTESTING FOR ENGINE SPARK
• Use approved spark plug tester.
CAUTION
Improper treatment of generator can damage it and
• DO NOT check for spark with spark plug removed.
shorten its life.
WARNING
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
65°C (150°F).
• Use generator only for intended uses.
• Operate generator only on level surfaces.
• DO NOT expose generator to excessive moisture, dust,
dirt, or corrosive vapors.
• DO NOT insert any objects through cooling slots.
Severe burns can occur on contact.
• If connected devices overheat, turn them off and disconnect
them from generator.
Combustible debris, such as leaves, grass,
brush, ect. can catch fire.
• Shut off generator if:
• DO NOT touch hot surfaces.
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
• Allow equipment to cool before touching.
• The generator must be at least 2m (5 ft) from structures
having combustible walls and/or other combustible materials.
• Keep at least 1m (3 ft) of clearance on all sides of
generator for adequate cooling, maintenance and servicing.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
KNOWYOUR GENERATOR
KNOWYOUR GENERATOR - MODEL 030212
Read this owner’s manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
Rocker
Switch
Petrol Tank
Oil Fill Cap/Dipstick
Recoil Starter
Choke Lever
Air
Cleaner
Receptacle
Grounding Fastener
Circuit Breaker
Air Cleaner — Protects engine by filtering dust and
Oil Fill Cap/Dipstick — Check and fill engine with oil
debris out of intake air
here.
Circuit Breaker — Receptacle is protected against
Choke Lever — Used when starting a cold engine.
electrical overload with circuit breaker.
Receptacle — May be used to supply electrical power
for the operation of various electrical, lighting, appliance,
tool and motor loads.
PetrolTank — Capacity of 3.8l (1 U.S. gallon).
Grounding Fastener — If required, please consult a
qualified electrician, electrical inspector, or the local
agency having jurisdiction.
Recoil Starter — Used for starting the engine.
Rocker Switch — Set switch to “On” prior to using
recoil starter. Set switch to “Off” to switch off generator.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
KNOWYOUR GENERATOR
KNOWYOUR GENERATOR - MODEL 030213
Read this owner’s manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
Rocker Switch
Petrol Tank
Recoil Starter
Oil Fill Cap/Dipstick
Choke Lever
Air
Cleaner
Receptacles
Circuit Breaker
ACVoltmeter
Grounding Fastener
AC Voltmeter — Indicates output voltage.
Oil Fill Cap/Dipstick — Check and fill engine with oil
here.
Air Cleaner — Protects engine by filtering dust and
debris out of intake air.
Choke Lever — Used when starting a cold engine.
Circuit Breaker — Receptacle is protected against
electrical overload with circuit breaker.
Receptacles — May be used to supply electrical power
for the operation of various electrical, lighting, appliance,
tool and motor loads.
PetrolTank — Capacity of 17 l (4.5 U.S. gallons).
Recoil Starter — Used for starting the engine.
Grounding Fastener — If required, please consult a
qualified electrician, electrical inspector, or the local
agency having jurisdiction.
Rocker Switch — Set switch to “On” prior to using
recoil starter. Set switch to “Off” to switch off generator.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY
Add Petrol
ASSEMBLY
Your generator requires some assembly and is ready for
use after it has been properly serviced with the
recommended oil and petrol.
NOTE: This engine is certified to operate on petrol only.
It will not operate on paraffin, diesel or other fuels.
WARNING
Petrol and its vapors are extremely flammable
and explosive.
Fire or explosion can cause severe burns or
death.
Remove Generator From Carton
1. Set carton on a rigid flat surface.
2. Carefully open top flaps of shipping carton.
WHEN ADDING PETROL
3. Cut down corners of carton from top to bottom
and lay sides of carton down flat.
• Turn generator OFF and let it cool at least 2 minutes
before removing petrol cap. Loosen cap slowly to relieve
pressure in tank.
• Fill petrol tank outdoors.
• DO NOT overfill tank.Allow space for petrol expansion.
4. Remove all packing material, carton fillers, etc.
5. Remove generator from shipping carton.
• Keep petrol away from sparks, open flames, pilot lights, heat,
and other ignition sources.
BEFORE STARTINGTHE
ENGINE
• DO NOT light a cigarette or smoke.
1. Use clean, fresh, regular UNLEADED petrol with a
minimum of 85 octane. DO NOT use petrol which
contains Methanol. DO NOT mix oil with petrol.
Add Engine Oil
• Place generator on a level surface.
2. Clean area around petrol fill cap, remove cap.
3A. For model 030212, slowly add regular unleaded
petrol to petrol tank. Be careful not to overfill.Allow
about 4cm (1.5") of tank space for petrol expansion
(Figure 1).
CAUTION
Any attempt to crank or start the engine before it has
been properly filled with the recommended oil will
result in equipment failure.
• Refer to engine manual for oil fill information.
Figure 1 - Petrol Expansion Space
• Damage to equipment resulting from failure to follow this
instruction will void warranty.
Tank
• Refer to engine owner’s manual and follow oil
recommendations and instructions.
Petrol
NOTE: Check oil often during engine break–in. Refer to
engine owner’s manual for recommendations.
NOTE: The generator assembly rotates on a
prelubricated and sealed ball bearing that requires no
additional lubrication for the life of the bearing.
3B. For model 030213, slowly add regular unleaded petrol
to petrol tank. Be careful not to fill above the baffle.
This allows adequate space for petrol expansion
(Figure 2).
Figure 2 — Petrol Expansion Space
Tank
Baffle
Petrol
4. Install petrol cap and wipe up any spilled petrol.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
USINGTHE GENERATOR
Generator Location
Generator Clearance
USINGTHE GENERATOR
System Ground
WARNING
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide will cause nausea,
fainting or death.
The generator has a system ground that connects the
generator frame components to the ground terminals on
the AC output receptacles.The system ground is
connected to the AC neutral wire (the neutral is bonded
to the generator frame).
• Operate generator ONLY outdoors.
Special Requirements
• Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes or other openings.
• DO NOT operate generator inside any building or
enclosure, including the generator compartment of a
recreational vehicle (RV).
There may be National regulations, local codes, or
ordinances that apply to the intended use of the
generator. Please consult a qualified electrician, electrical
inspector, or the local agency having jurisdiction.
The generator must be at least 2m (5 ft.) from structures
having combustible walls and/or other combustible
materials. Leave at least 1m (3 ft.) all around generator
including overhead, for adequate cooling, maintenance
and servicing.
• In some areas, generators are required to be registered
with local utility companies.
• If the generator is used at a construction site, there
may be additional regulations which must be observed.
Place generator in a well ventilated area, which will allow
for removal of deadly exhaust gas. DO NOT place
generator where exhaust gas could accumulate and enter
inside or be drawn into a potentially occupied building.
Ensure exhaust gas is kept away from any windows,
doors, ventilation intakes or other openings that can
allow exhaust gas to collect in a confined area (Figure 3).
Prevailing winds and air currents should be taken into
consideration when positioning generator.
Connecting to a Building’s
Electrical System
Connections for standby power to a building’s electrical
system must be made by a qualified electrician.The
connection must isolate the generator power from utility
power, and must comply with all applicable laws and
electrical codes.
WARNING
Generator produces powerful voltage.
Figure 3 — Generator Clearance
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
• When using generator for backup power, notify utility
company. Use approved transfer equipment to isolate
generator from electric utility.
• Use a ground fault circuit interrupter (GFCI) in any damp
or highly conductive area, such as metal decking or steel
work.
Typical Generator Shown
• DO NOT touch bare wires or receptacles.
• DO NOT use generator with electrical cords which are
worn, frayed, bare or otherwise damaged.
• DO NOT operate generator in the rain.
• DO NOT handle generator or electrical cords while
standing in water, while barefoot, or while hands or feet are
wet.
Exhaust Port
• DO NOT allow unqualified persons or children to operate
or service generator.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATINGTHE GENERATOR
NOTE: If engine starts after 3 pulls but fails to run, or if
OPERATINGTHE
unit shuts down during operation, make sure unit is on a
level surface and check for proper oil level in crankcase.
This unit may be equipped with a low oil protection
device. See engine manual.
GENERATOR
CAUTION
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
WARNING
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
65°C (150°F).
Severe burns can occur on contact.
Combustible debris, such as leaves, grass,
brush, ect. can catch fire.
• See “Don’t Overload Generator”.
• Start generator and let engine stabilize before connecting
electrical loads.
• Connect electrical loads in OFF position, then turn ON for
operation.
• DO NOT touch hot surfaces.
• Turn electrical loads OFF and disconnect from generator
before stopping generator.
• Allow equipment to cool before touching.
• The generator must be at least 2m (5 ft) from structures
having combustible walls and/or other combustible materials.
Starting the Engine
Disconnect all electrical loads from the generator. Use
the following start instructions:
• Keep at least 1m (3 ft) of clearance on all sides of
generator for adequate cooling, maintenance and servicing.
1. Make sure unit is on a level surface.
Connecting Electrical Loads
• Let engine stabilize and warm up for a few minutes
after starting.
IMPORTANT: Failure to start and operate unit on a
level surface will cause the unit not to start or shut down
during operation.
• Plug in and turn on the desired 230 Volt AC, single
phase, 50 Hz electrical loads.
2. Turn petrol valve to “On” position (Figure 4).
Figure 4 — PetrolValve
• DO NOT connect 3–phase loads to the generator.
• DO NOT connect 60 Hz loads to the generator.
PetrolValve is shown
in “On” position
• DO NOT OVERLOADTHE GENERATOR. See
“Don’t Overload Generator”.
Stopping the Engine
1. Turn OFF and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with
electrical devices plugged in and turned ON.
3. Start engine according to instructions given in engine
owner’s manual.
WARNING
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains
could result.
2. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and
generator.
3. Turn engine off according to instructions given in the
engine owner’s manual.
4. Move petrol valve to “Off” position.
• When starting engine, pull cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
• NEVER start or stop engine with electrical devices plugged
in and turned on.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATINGTHE GENERATOR
Figure 5 — 230Volt AC, 20 Amp Receptacle
3-Wire Cord Set
RECEPTACLES
CAUTION
Receptacles may be marked with rating value greater
than generator output capacity.
• NEVER attempt to power a device requiring more
amperage than generator or receptacle can supply.
• DO NOT overload the generator. See “Don’t Overload
Generator”.
230V
ACVoltmeter (Model 030213 Only)
Use the voltmeter as a visual aid. It indicates AC voltage.
If the meter indicates that AC output voltage is far below
230Volts, engine speed or frequency may be too low.
Ground
Circuit Breaker
The model 030212 circuit breaker is rated at 10 Amps.
The model 030213 circuit breaker is rated at 15 Amps.
This circuit breaker, when tripped, will cut off power to
all 230Volt outlets.To reset the breaker, set the switch to
the “On” position.When the switch is in the “Off”
position the engine may be running but no power is
supplied to the outlets.
For model 030212, this receptacle powers 230Volt AC,
50 Hz, single phase loads requiring up to 2,500 Watts of
power (2.5 kW) at 10 Amps for 230Volts.
For model 030213, these receptacles power 230Volt AC,
50 Hz, single phase loads requiring up to 2,800 Watts of
power (2.8 kW) at 12.1 Amps for 230Volts total.
COLD WEATHER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] combined with high humidity), your generator
may experience icing of the carburetor and/or the
crankcase breather system.To reduce this problem, you
need to perform the following:
230Volt AC, 20 Amp, Locking
Receptacle
Use a compatible 3 prong plug with this receptacle
(Figure 5). Connect a 3-wire cord set rated 250 volts at
20 AC Amps to the plug.
1. Make sure generator has clean, fresh petrol.
2. Open petrol valve (turn valve to open position).
3. Use SAE 5W-30 oil (synthetic preferred, see engine
manual).
4. Check oil level daily or after every eight (8) hours of
operation.
5. Maintain generator following “Maintenance Schedule”
in engine manual.
6. Shelter unit from elements.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATINGTHE GENERATOR
4. Plug in and turn on the next load.
DON'T OVERLOAD
GENERATOR
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
NEVER add more loads than generator capacity.Take
special care to consider surge loads in generator capacity,
as described above.
Capacity
You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items
you will power at the same time. Follow these simple
steps:
Figure 6 - Wattage Reference Chart
Additional
Surge
(Starting)
Watts
Rated*
(Running)
Watts
Tool or Appliance
Essentials
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items. See
Figure 6.
Light Bulb - 75 watt
Deep Freezer
Sump Pump
Refrigerator/Freezer - 18 Cu. Ft.
Water Well Pump - 1/3 HP
Heating/Cooling
75
500
800
800
1000
-
500
3. Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances.Total surge watts is estimated by adding
only the one item with the highest additional surge
watts to the total rated watts from step 2.
1200
1600
2000
Window Fan
Furnace Fan Blower - 1/2 HP
Kitchen
300
800
600
1300
For Example:
Microwave Oven - 1000 Watt
Coffee Maker
Electric Stove - Single Element
Hot Plate
1000
1500
1500
2500
-
-
-
-
Rated (Running)
Watts
Additional Surge
(Starting) Watts
Tool or Appliance
Refrigerator
Deep Freezer
Television
800
500
500
75
1600
Family Room
500
Stereo Receiver
Television - 27”
Personal Computer w/17” monitor
Other
450
500
800
-
-
-
-
-
Light (75 Watts)
1875 Total Running 1600 Highest Surge
Watts Watts
AM/FM Clock Radio
Electric Water Heater - 40 Gallon
Quartz Halogen Work Light
Airless Sprayer - 1/3 HP
Reciprocating Saw
Electric Drill - 1/2 HP
Circular Saw - 7 1/4”
Miter Saw - 10”
300
4000
1000
600
-
-
-
Total Rated (Running) Watts
Highest Additional Surge Watts
= 1875
= 1600
1200
960
1000
1500
1800
2000
2500
960
Total Generator Output Required = 3475
1000
1500
1800
2000
2500
Power Management
It is important to take care when adding electrical loads
to your generator.The correct and safe way to manage
generator power is to sequentially add loads as follows:
Table Saw/Radial Arm Saw - 10”
Air Compressor - 1-1/2 HP
*Wattages listed are approximate only. Check tool or
appliance for actual wattage.
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the
largest load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS / MAINTENANCE
Generator Maintenance
SPECIFICATIONS
Generator maintenance consists of keeping the unit clean
Model 030212
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with
snow, leaves or any other foreign material.
Maximum Surge Watts . . . . . . . . . . . . . . . . . .3,250 watts
Continuous Wattage Capacity . . . . . . . . . . . .2,500 watts
Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous AC Load Current:
At 230Volts . . . . . . . . . . . . . . . . . . . . . . . . . .10 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .50 Hertz
Petrol Tank Capacity . . . . . . . . . . . . 3.78 l (1 U.S. gallons)
Shipping Weight. . . . . . . . . . . . . . . . . . . . 33.6 kg (74 lbs.)
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine petrol system and cause
problems. In addition, if water enters generator through
cooling air slots, some of the water will be retained in
voids and cracks of the rotor and stator winding
insulation.Water and dirt buildup on the generator
internal windings will eventually decrease the insulation
resistance of these windings.
Model 030213
Maximum Surge Watts . . . . . . . . . . . . . . . . . .4,200 watts
Continuous Wattage Capacity . . . . . . . . . . . .2,800 watts
Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous AC Load Current:
WARNING
At 230Volts . . . . . . . . . . . . . . . . . . . . . . . . .12.1 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .50 Hertz
Petrol Tank Capacity . . . . . . . . . . . . 17 l (4.5 U.S. gallons)
Shipping Weight . . . . . . . . . . . . . . . . . . . . . 40 kg (88 lbs.)
Unintentional sparking can result in fire or
electric shock.
WHEN ADJUSTING OR MAKING REPAIRSTO
YOUR GENERATOR
• Disconnect the spark plug wire from the spark plug and
place the wire where it cannot contact spark plug.
GENERAL
MAINTENANCE
RECOMMENDATIONS
WHENTESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the
unit is kept clean and properly stored. NEVER operate
a damaged or defective generator.
Generator Cleaning
• Use a damp cloth to wipe exterior surfaces clean.
CAUTION
Improper treatment of generator can damage it and
shorten its life.
Engine Maintenance
See engine owner’s manual for instructions.
• DO NOT expose generator to excessive moisture, dust,
dirt, or corrosive vapors.
CAUTION
Avoid prolonged or repeated skin contact with used
motor oil.
• DO NOT insert any objects through cooling slots.
• Use a soft bristle brush to loosen caked on dirt or oil.
• Use a vacuum cleaner to pick up loose dirt and debris.
• Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
• Use low pressure air (not to exceed 25 psi) to blow
away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.
• Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN.
DON'T POLLUTE. CONSERVE RESOURCES.
RETURN USED OIL TO COLLECTION
CENTERS.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
STORAGE
Engine Storage
STORAGE
See engine owner’s manual for instructions.
The generator should be started at least once every
seven days and allowed to run at least 30 minutes. If this
cannot be done and you must store the unit for more
than 30 days, use the following guidelines to prepare it
for storage.
Other StorageTips
• To prevent gum from forming in petrol system or on
essential carburetor parts, add petrol stabilizer into
petrol tank and fill with fresh petrol. Run the unit for
several minutes to circulate the additive through the
carburetor.The unit and petrol can then be stored for
up to 24 months. Petrol stabilizer can be purchased
locally.
Generator Storage
• Clean the generator as outlined in “Generator
Cleaning”.
• Check that cooling air slots and openings on generator
are open and unobstructed.
• DO NOT store petrol from one season to another
unless it has been treated as described above.
• Replace petrol container if it starts to rust. Rust and/or
dirt in petrol can cause problems if it's used with this
unit.
WARNING
Storage covers can be flammable.
• Store unit in a clean and dry area.
• DO NOT place a storage cover over a hot generator.
• Let equipment cool for a sufficient time before placing the
cover on the equipment.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
TROUBLESHOOTING
Problem
Cause
Solution
1. Circuit breaker is open.
1. Reset circuit breaker.
2. Check and repair.
2. Poor connection or defective
cord set.
Engine is running, but no AC
output is available.
3. Connected device is bad.
3. Connect another device that is in
good condition.
4. Fault in generator.
4. Contact Briggs and Stratton
service facility.
1. Short circuit in a connected load. 1. Disconnect shorted electrical
load.
Engine runs good but bogs down
when loads are connected.
2. Generator is overloaded.
3. Shorted generator circuit.
2. See "Don't Overload Generator".
3. Contact Briggs and Stratton
service facility.
1. Out of petrol.
1. Fill petrol tank.
Engine will not start; or starts
and runs rough.
2. Petrol valve is in the "Closed"
2. Turn petrol valve to the "Open"
position.
position.
3. Low oil level.
3. Fill crankcase to proper level.
1. Fill petrol tank.
1. Out of petrol.
Engine shuts down during
operation.
2. Low oil level.
2. Fill crankcase to proper level.
3. Place generator on level surface.
3. Generator tipped at angle.
Engine lacks power.
Load is too high.
See "Don't Overload Generator".
14
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
NOTES
15
Download from Www.Somanuals.com. All Manuals Search And Download.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY
Effective September 1, 2004 replaces all undated Warranties and all Warranties dated before September 1, 2004
LIMITED WARRANTY
Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material
or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by
purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY
AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED
TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty
lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state
to state or country to country.
OUR EQUIPMENT*
OUTBOARD
MOTOR
PRESSURE
WASHER
WATER PUMP
PORTABLE
GENERATOR
HOME STANDBY GENERATOR SYSTEM
WELDER
Less than 10 KW 10 KW or greater
Transfer switch
WARRANTY PERIOD**
3 years or
2 years
Consumer Use
2 years
none
1 year
1 year
2 years
1 year
3 years
none
1500 hours
Commercial Use
90 days
90 days
none
none
*
The engine and starting batteries are warranted solely by the manufacturers of those products.
**
2 years for all consumer products in the European Union. Parts only on 2nd year for consumer use of Portable Generator and
Home Standby Generator System - Less than 10 KW, outside of European Union.
The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time
stated in the table above. “Consumer use" means personal residential household use by a retail consumer. “Commercial use" means all other
uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter
be considered as commercial use for purposes of this warranty. Equipment used for prime power in place of utility are not applicable to
this warranty. Electric powered pressure washers used for commercial purposes are not warranted.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR
PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY
SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY
PERIOD.
ABOUT YOUR WARRANTY
We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most
warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would
not apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper
installation. Similarly, the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment
has been altered or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon
examination, is found to be defective under normal use and service. This warranty will not cover the following repairs and equipment:
•
•
Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does
not cover repair when normal use has exhausted the life of a part or the equipment.
Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized
installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage
so as, in our judgment, to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as
adjustments, fuel system cleaning and obstruction (due to chemical, dirt, carbon, lime, etc.).
•
Other Exclusions: This warranty excludes wear items such as quick couplers, oil gauges, belts, o-rings, filters, pump packing, etc., pumps
that have been run without water supplied or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or improper
servicing or freezing or chemical deterioration. Accessory parts such as guns, hoses, wands and nozzles are excluded from the product
warranty. This warranty excludes failures due to acts of God and other force majeure events beyond the manufacturers control. Also excluded
is used, reconditioned, and demonstration equipment; equipment used for prime power in place of utility power and equipment used in life
support applications.