Braun Personal Lift Braun Corporation FMVSS No 403 User Manual

Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32553 Rev. A  
Braun Corporation FMVSS No. 403  
Locate Lift Mounting Brackets  
1
Rev: A  
Quick Reference Installation Sheet 32253  
Figure C  
Locate All-Thread Mounting  
Brackets  
“DOT — Public Use Lift”  
CENTER  
VEHICLE  
NHTSA Vehicle Physical Requirements  
ACROSS  
CENTER IN  
FRAME  
1. Open both doors to 90°.  
“DOT - Public Use Lift” veries this platform lift  
meets the “public use lift” requirements of FMVSS  
No. 403. This lift may be installed on all vehicles  
appropriate for the size and weight of the lift, but  
must be installed on buses, school buses, and  
multi-purpose passenger vehicles other than  
motor homes with a gross vehicle weight rating  
(GVWR) that exceeds 4,536 kg (10,000 lb).  
Vehicle Requirements:  
DOOR OPNING  
2. Locate center of door opening  
(between doors). Mark the  
center point.  
C
L
All vehicles with a GVW over 6000 lbs.  
and with unmodied OEM framerails.  
NING  
3. Transfer center point to the  
vehicle frame. Using a front-  
to-rear framing member as a  
guide, transfer the center point  
across chassis to opposite side  
front-to-rear framing member  
(must be 90° to door opening).  
Lift mounting bracket positions  
are based on this center line.  
Alternative oor structures are allowed  
providing the installed lift system pass-  
es all FMVSS 403 requirements.  
90  
OPE  
DOOR  
22-3/8"  
Mounting Bracket Requirements:  
22-3/8"  
4"  
44-3/  
A maximum distance of 16" from the  
outermost mounting bracket to the  
end of the cassette.  
All-Thread  
Mounting  
Brackets  
4. Measure 22-3/8" to left and  
right of the center line to  
achieve the 44-3/4" center-to-  
center spacing of all-thread  
mounting studs.  
CLE ER  
VEHI  
All four mounting brackets must be  
connected to the framerails.  
CHASSIS MEMB  
All-thread  
Mounting  
Brackets  
5. Clamp the mounting brackets  
securely in place (all-thread  
studs must be vertical).  
ER  
VEHICLE  
S
MEMB  
CHASSI  
Engage Platform Manual  
Release System: The lift  
cable-activated platform  
manual release is disengaged  
during shipment to prevent  
potential drive chain stretch.  
Handle the lift with care. En-  
gage manual release before  
attempting to install (raise, tilt  
or move) the lift.  
Figure A  
16  
Maximum  
B
Door Opening Dimensions  
A
WARNING  
Vehicle lift access door opening  
must meet specied dimensions.  
Engage manual  
release before  
attempting to install  
(raise, tilt or move)  
lift. Failure to do so  
may result in serious  
bodily injury and/or  
property damage.  
855  
Minimum Clear Door  
Opening Height  
A
B
C
NA  
43-1/2"  
50"  
C
A
R
N
IN  
G
Clear Door Opening Width  
Maximum Floor-to-Ground  
Pu  
sh  
ma  
T
-ha  
a
n
n
u
ndl  
e
in  
d
oally  
m
l
o
c
u
t
o
v
ful  
Fa  
k
b
e
f
to  
e
n
e
p
l
a
l
y
a
i
l
u
o
r
ga  
t
f
o
n
d
r
e
s
r
e
t
e
d
ge  
r
m
u
l
t
o
l
o
r
i
v
i
p
l
a
in  
d
e
i
n
c
n
g
t
f
o
p
l
o
k
p
l
v
r
m
pla ymun  
restfor  
i
n
a
t
e
h
i
en  
t
e
n
f
o
r
m
c
l
e
.
u
l
t
m
d
e
t.  
U
n
d
ed  
ma  
tfo  
a
n
i
n
p
l
i
n
pla  
y
rm  
d
/
o
r
s
e
o
y
t
e
n
p
r
o
r
i
o
u
s
m
e
n
t
d
e
d
pe  
bo  
m
rty  
d
a
y
i
l
D
o
da  
ma in  
jur  
ge  
y
n
o
.
y
Figure B  
t
r
e
m
8182  
3
o
v
e
!
Download from Www.Somanuals.com. All Manuals Search And Download.  
Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32553 Rev. A  
Electrical, Hydraulic and Interlock  
3
Min.  
1-3/4”  
Jumper Wire  
5/16"  
Lag Bolts  
(typical - 4)  
Pump Module Mounting  
Hydraulics:  
Circuit Sentry:  
Figure K  
to  
Lead  
Cable  
Install black jumper wire  
last. Install the black jumper  
wire in pump Terminal Strip  
terminals 6 and 9 after all  
other electrical connections  
have been made (see Panel  
4). The jumper wire supplies  
power to the circuit board.  
Check oor level and inner roll  
stop adjustments as detailed  
in Panel 4 before operating  
lift with electric pump.  
Wa  
Pos.  
Mount reinforcement “L” bracket  
to pump mounting bracket as  
shown in Figure K. Secure  
pump mounting bracket to oor  
using four 5/16" lag bolts.  
l
l
Mount  
Pump  
Remove the plug  
from 1/4" diameter  
clear vent tube.  
See Figure N.  
Neg.  
Pump  
Power Cable  
V
ertical  
Mounting  
Bracket  
try  
Through-Floor  
Cable and Hose  
Grommet  
(3" Diameter  
Mounting Hole)  
Circuit  
Sen  
1/4-20 x 3/8"  
Hex Screws  
Bat.  
Pump  
Route hydraulic  
hose assembly  
through oor  
grommet to quick-  
disconnect tting at  
lift. Connect hose.  
Install Circuit  
must  
face  
Out  
Check under vehicle for  
obstructions before drilling,  
cutting holes or installing  
oor mounting hardware.  
12"  
Max.  
Sentry as shown  
in Figure M. At-  
tach power cable  
and lead cable as  
detailed.  
Aux.  
Lock  
Washer  
Figure M  
stic  
1/8" x 4" x 4"  
Pla  
Note: Locate and drill pump  
module mounting holes, oor  
grommet 3" diameter hole and  
manual release 7/8" diameter  
hole before mounting pump.  
Note:  
Connect red positive  
(+) power cable here  
(from Circuit Sentry).  
Optional Interlock Kits  
Vehicle and Lift Interlocks  
Remove  
plug from  
vent tube.  
Figure N  
Reinforcement  
“L” Bracket  
Universal Interlock Kit  
30940K is available  
for easy interface with  
vehicle OEM electronic  
signals.  
The pump module is equipped  
with a lift interface 9-circuit  
connector (female socket).  
A mating 9-circuit connector  
(male plug) is supplied.  
Cable-activated Manual  
Note: Seal the  
Release: The T-handle must  
be mounted inside the vehicle.  
The cable must operate freely  
(no kinks or bends). Warning  
tag 81823 must remain attached  
to the handle. Remove handle  
for installation.  
1
Cable-activated  
Manual Release  
(from lift)  
7/8" Diameter  
Mounting Hole  
oor cable and  
hose grommet  
following installa-  
tion procedures  
(ll with silicone).  
Disconnect  
and remove  
eye terminal  
Instrument Panel Display  
Kit 30938K provides an  
LED Panel Display that  
interfaces with Braun  
Universal Interlock Kit  
30940K.  
To meet minimum  
Lift  
o
T
NHTSA requirements,  
connect to vehicle inter-  
lock harness as outlined  
in Figure N (Steps 1-4).  
Note: All  
wiring harness  
connections  
must be  
inside the  
vehicle.  
Pump Ground Cable:  
Vehicle Battery Ground Cable:  
2
Disconnect  
Note: Detailed installa-  
tion instructions are sup-  
plied with interlock kits.  
One ground cable is pump  
mounted. Route this ground cable  
through the oor grommet and con-  
nect to a vehicle framing member  
(see Figure L).  
A ground cable (minimum 2 gauge)  
must be connected from vehicle  
battery negative post to the same  
vehicle framing member the pump  
ground cable is attached to.  
ring  
i
W
es  
Main Lift  
Harness  
m
4
lar  
Connect  
5/16"  
External Tooth  
Star Washer  
Strobe A  
shold Mat  
Thre  
tform Lights  
res labeled)  
(wi  
Ground Cable Corrosion:  
When mounting ground  
cables, remove undercoat-  
ing, dirt, rust, etc. from  
framing member around  
mounting holes. Apply  
protective coating to mount-  
ing holes to prevent corro-  
sion. Failure to do so will  
void warranty of certain  
electrical components.  
Pla  
9/32"  
Diameter  
Pilot Hole  
T
o
Interlock  
Chassis  
LIFT S  
Housing/Carriage Har-  
nesses:  
Beeper/Strobe Alarm  
and Platform Lights:  
Threshold Warning Sensor:  
Thread  
Cutting  
Screw  
(Y  
ellow/Light  
3
SIGNATL  
OWED  
Connect vehicle  
interlock signal wires  
Connect harness to mating har-  
ness at pump module (labeled).  
Mat must be installed on a at  
rigid surface. Inboard edge of mat  
must be minimum 18" from edge  
of nished oor or stepwell.  
VEHICLE SECURE  
Blue)  
Route two main wiring  
harnesses from lift through  
oor grommet to pump  
module. Connect to mat-  
ing harnesses at pump.  
Connect harnesses to  
mating harnesses at  
pump (labeled). Detailed  
installation instructions  
supplied with kits.  
SIG  
(Gr  
NAL  
ey/Red)  
Figure L  
Ground Cable Mounting  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32553 Rev. A  
FMVSS 403/404 Certification Checklist  
5
Door Operators/Switch, Terminal  
Strip and Floor Level Adjustment  
4
Visual and Audible  
Threshold Warning  
DOT — Public Use Lift  
Public use vehicle manufacturers  
are responsible for complying with  
the lift lighting requirements in Fed-  
eral Motor Vehicle Safety Standard  
No. 404, Platform Lift Installation in  
Motor Vehicles (49 CFR 571.404).  
Terminal Strip  
Power Door Operators  
To Door Openers  
“Open” Trigger  
The pump-mounted  
terminal strip provides  
additional inputs and  
outputs that can be  
used for optional door  
operators, beepers,  
interlocks, etc. - as  
well as the door safety  
switch. The black  
jumper wire must be  
installed in terminals 6  
and 9 to supply power  
to the circuit board.  
Install optional  
C_SW  
O_RL  
N/C  
Orange  
Black  
power door oper-  
ators as detailed  
in the instructions  
supplied with  
Platform  
Lighting  
IN_LK  
12_V  
PWR  
GND  
Door Cutout  
Door Cutout  
door operator kit.  
LD  
FO  
LD  
FO  
UN  
UP  
D
Threshold  
Area  
F_LV  
O_SW  
C_RL  
Route the wires  
to the pump mod-  
ule and connect  
to the terminal  
strip as shown in  
Figure P.  
Red  
Blue  
To Door Openers  
“Close” Trigger  
Figure O  
Figure P  
ld  
sor Mat  
Thresho  
Sen  
Inner  
Roll Stop  
Floor Level and Inner Roll Stop Adjustments  
Ensure the lift is positioned and secured as speci-  
ed above (panels 1 and 2). Adjust the Floor  
Level switch rst (detailed below). Then, adjust  
the inner roll stop as detailed in the service manual  
(adjust only if necessary). The inner roll stop must  
rest properly on the vehicle oor for wheelchair  
entry and exit.  
Achieving proper oor level positioning of the  
platform and inner roll stop requires a combina-  
tion of Floor Level switch adjustment and inner  
roll stop adjustment. Both are factory set but  
must be inspected during installation procedures  
(will vary per vehicle application).  
JKA  
Dual  
Outer Barrier  
Platform  
Floor Level Switch  
The operations listed below must be  
functionally veried.  
Floor Level Switch  
Floor Level Cam  
The Floor Level switch stops upward travel of  
the platform during the Up function (activated  
by the torque tube-mounted Floor Level cam).  
Position the lift platform 1" above oor level  
using the manual operation system (de-  
tailed on opposite side of this sheet). Loosen  
the clamp securing the torque tube-mounted  
Floor Level cam. Rotate the cam until the  
Floor Level switch is activated (cam depresses  
switch).  
Vehicle movement is prevented unless the lift  
door is closed, ensuring the lift is stowed.  
Lift operation shall be prevented unless the  
vehicle is stopped and vehicle movement is  
prevented.  
Platform movement is prohibited beyond  
the position where the inner roll stop is fully  
deployed (up).  
The platform will not fold/stow if occupied.  
The outer barrier will not raise if occupied.  
The inner roll stop will not raise if occupied.  
A visual and audible warning will activate if  
the threshold area is occupied when the plat-  
form is at least one inch below oor level.  
Note: Check the oor level position of the plat-  
form and the inner roll stop after powering the  
pump. Hydraulic pressure may affect platform  
height slightly. Fine tuning adjustment (tweak-  
ing) of the Floor Level switch may be required.  
Lift platform movement shall be interrupted  
unless the outer barrier is deployed (up).  
Torque Tube  
Cam depressing switch.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32553 Rev. A  
Lift Operating Instructions  
Lift Operating Instructions  
Note: The instructions out-  
lined here are applicable for  
“Public-Use” NUVL lift mod-  
els equipped with dual  
folding handrails and a dual  
outer barrier system.  
Handrails and Dual Outer Barrier:  
The folding handrails and tall outer  
barrier are manually operated. The  
spring-loaded outer barrier (tall barrier)  
and the handrails rest on the platform  
when the lift is not in use. The outer  
barrier must be raised to the vertical  
position and the handrails must be  
lifted to the vertical position whenever  
a passenger is on the platform.  
OPEN DOOR(S) AND SECURE  
TO LOAD PASSENGER:  
Before lift operation, park the  
vehicle on a level surface, away  
from vehicular trafc. Place the  
vehicle transmission in “Park”  
and engage the parking brake.  
Open manual doors fully, being  
certain the doors are secured in  
the fully open position.  
Manually open door(s) fully and  
secure.  
1. Read Notes below! Load pas-  
senger onto platform and lock  
wheelchair brakes.  
WARNING  
TO DEPLOY PLATFORM:  
Whenever a  
passenger is on the  
platform, the:  
• Passenger must  
be positioned  
fully inside yellow  
boundaries  
• Wheelchair brakes  
must be locked  
• Inner roll stop and  
outer barrier must  
be up.  
Failure to do so may  
result in serious  
bodily injury and/or  
property damage.  
Note: Outer barrier must be fully  
unfolded (ramp position) until the  
entire wheelchair (or standee) has  
crossed the outer barrier.  
1. Stand clear and press the UP  
switch until the platform extends  
fully. Release switch.  
The tall outer barrier and the handrails  
must be folded down to the platform  
(horizontal) position before stowing  
the lift. The handrails fold down onto  
the outer barrier to secure the barrier  
in the horizontal position.  
It is the responsibility of the lift  
operator (attendant) to prop-  
erly open, secure and close the  
vehicle lift doors, to activate any  
auxiliary interlock (if equipped),  
to load and unload the wheel-  
chair passenger (or standee) on  
and off the lift platform, and to  
properly activate all lift functions.  
2. Pull handrail detent pins, lift  
handrails up to vertical position and  
reinsert detent pins.  
Note: Passenger must be  
positioned fully inside yellow  
boundaries.  
3. Lift outer barrier to vertical position.  
2. Press UP switch to fold outer bar-  
rier UP fully (vertical), raise the  
platform to oor level and unfold  
inner roll stop to oor level. Re-  
lease switch.  
Each handrail is secured with two de-  
tent pins (one pin at the base of each  
vertical support tube). The detent pins  
must be removed before the handrails  
can be folded or unfolded and the  
detent pins must be reinserted after  
folding or unfolding the handrails.  
4. Press the UP switch until the plat-  
form stops (raises to oor level)  
and inner roll stop unfolds to oor  
level. Release switch.  
In event of power or equipment  
failure, refer to the Manual Oper-  
ating Instructions section.  
3. Unlock wheelchair brakes and  
unload passenger from platform.  
TO UNLOAD PASSENGER:  
Hand-held Pendant Control:  
1. Read Note below! Load pas-  
senger onto platform and lock  
wheelchair brakes.  
TO STOW PLATFORM:  
DOOR  
STOW  
The hand-held attendent's pendant control is  
equipped with four push button switches (DOOR,  
STOW, DOWN and UP). The momentary switches  
activate the automatic lift functions. Simply press  
the switch labeled for the intended function.  
1. Fold outer barrier down to platform  
(horizontal) position.  
Note: Passenger must be  
positioned fully inside yellow  
boundaries and outer barrier must  
be UP.  
2. Pull handrail detent pins, fold hand-  
rails down to platform (horizontal)  
position and reinsert detent pins.  
DOWN  
UP  
When there is power to the lift, the lift function labels  
illuminate to identify the functions.  
2. Press DOWN switch until the entire  
platform reaches ground level and  
the outer barrier unfolds fully  
3. Press STOW switch until platform  
stops (retracts fully). Release  
switch.  
Control Switch Functions:  
(ramp position). Release switch.  
UP: From the stowed position, pressing the UP  
switch deploys (extends) the platform fully. Release  
the UP switch once the platform has extended fully  
in order to deploy the outer barrier and handrails.  
The platform will continue to raise to oor level if the  
UP switch is not released and handrail procedures  
may be more difcult (oor level height varies per  
vehicle). Pull the handrail detent pins and lift the  
handrails to the vertical position. Reinsert the de-  
tent pins after the handrails are raised. Lift the outer  
barrier to the vertical position. Press the UP switch  
until the platform stops (raises to oor level), and the  
inner roll stop unfolds to oor level.  
CLOSE DOOR(S)  
3. Unlock wheelchair brakes and  
unload passenger from platform.  
Manually close door(s) fully.  
STOW: The STOW function raises or lowers the  
platform to stow level and then moves the platform  
inward (retracts) to the stow position. Handrails  
and Outer Barrier: The tall outer barrier and the  
handrails must be folded down to the platform  
(horizontal) position before stowing (retracting)  
the platform. The handrail detent pins must be re-  
inserted before stowing the platform also. Note:  
The lift will not stow with weight on the platform  
(built-in safety feature).  
Note: Outer barrier must be fully  
unfolded (ramp position) until the  
entire wheelchair (or standee) has  
crossed the outer barrier.  
DOOR CLOSE: This function is not applicable  
for “Public-Use” NUVL lift models (manual door  
system and attendant operated lift).  
From ground level, the UP function will rst au-  
tomatically raise (rotate) the outer barriers to the  
upright (vertical) position. The platform then raises  
to oor level position. Note: The lift will not raise  
if the outer barrier is not in the UP position (built-in  
safety feature).  
Note: If any of these functions do not occur as  
described, discontinue lift use immediately and  
contact your sales representative or call The  
Braun Corporation at 1-800-THE LIFT®. One of  
our national Product Support representatives will  
direct you to an authorized service repairman who  
will inspect your lift.  
DOWN: The DOWN function lowers the platform  
to ground level and then unfolds the outer barriers  
to the ramp (horizontal) position. From the stowed  
position, the lift will extend fully and then lower.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32553 Rev. A  
Manual Operating Instructions  
Manual Operating Instructions  
In event of power or equipment  
failure, refer to the Manual  
Operating Instructions to manu-  
ally operate the lift. Refer to the  
Lift Operating Instructions for all  
normal lift operation procedures  
(such as loading and unloading  
passengers). Follow all Lift  
Operation Safety Precautions  
at all times!  
T-handle release cable re-  
leases and engages the lift  
platform to allow the platform  
to be manually extended and  
retracted. The manual back-  
up pump (hand pump) is  
Hand  
Pump  
OUT (TO EXTEND PLATFORM):  
Pump  
Handle  
1. Pull T-Handle.  
T-Handle  
Release  
Cable  
2. Turn T-Handle to lock platform in re-  
leased position.  
3. Pull platform out.  
4. Turn T-Handle.  
5. Push T-Handle in.  
W
A
R
N
IN  
G
POWER  
PACK  
used to manually lower and  
raise the extended platform.  
Push  
man  
T
-han  
uall  
and  
dle  
mo  
i
n
y
o
l
o
c
u
t
t
ful  
k
bef  
o
e
ve  
p
ly  
ngaglat and  
Fail  
ur  
ore  
form in  
pl  
res  
e
t
dri  
e
u
o
lock  
u
p
v
deploltyiment.  
U
nin  
atfo  
n
g
ve  
rm  
icl  
ma  
plat  
res  
and/lt  
nintend  
lat  
h
fo  
u
form  
ed  
intendlaetdfor  
e.  
rm dep  
i
p
y
n
s
loyment may  
or pro  
e
p
r
e
i
r
m
ous bodi  
ty  
d
ly inju  
ag  
e. ry  
a
D
m
o
n
o
t
rem  
81  
82  
3
o
ve!  
The location of the power  
pack and release cable var-  
ies from vehicle to vehicle  
(depending on your particular  
installation).  
Valve  
6. Turn T-Handle to lock platform in en-  
gaged position.  
VALVE  
Familiarize yourself with the  
components necessary to  
manually operate the lift. The  
Note: Location of power  
pack and T-handle varies.  
DOWN (TO LOWER PLATFORM):  
Using hand pump handle, open hand pump  
valve (turn counterclockwise). Open 1/2  
turn only.  
OPEN  
CLOSE  
Cable-Activated Platform Manual Release System  
DOWN (TO UNFOLD OUTER BARRIER):  
1. Remove hairpin cotter from detent pin.  
2. Remove detent pin.  
3. Unfold (rotate) barrier down.  
Hairpin  
Cotter  
Platform Manual Release Sys-  
Failure to manually lock the plat-  
form carriage assembly (re-en-  
gage the carriage assembly drive  
chain) after manual deployment,  
will allow the platform to roll in or  
out of housing unhindered during  
vehicle movement. Failure to lock  
the platform will also allow the  
platform to roll in or out of hous-  
ing unhindered during hand pump  
raising and lowering procedures.  
tem: A cable-activated manual  
release system releases and  
engages the platform carriage  
assembly drive chain to allow the  
platform carriage assembly to be  
manually moved out (extended)  
or moved in (retracted) as need-  
ed. A T-handle is provided on the  
release cable for activation of the  
manual release system (details  
follow).  
W
ARNING  
Actuato  
r
Detent  
Pin  
UP (TO FOLD OUTER BARRIER):  
TFORM  
PLA  
1. Fold (rotate) barrier up.  
2. Insert detent pin.  
3. Insert hairpin cotter in detent pin.  
OUTER BARRIER  
Push T-handle in fully and  
manually move platform in  
and out to engage platform  
lock before driving vehicle.  
Failure to lock platform may  
result in unintended platform  
deployment. Unintended  
platform deployment may  
result in serious bodily injury  
and/or property damage.  
UP (TO RAISE PLATFORM):  
VALVE  
After manually releasing  
After manually moving the  
platform, push manual release  
T-handle in fully and ensure  
platform is locked before driv-  
ing lift vehicle. Uncontrolled  
and unintentional platform de-  
ployment (inadvertent platform  
ejection) may result in serious  
bodily injury and/or property  
damage.  
Using hand pump handle:  
1. Close hand pump valve (turn clockwise).  
2. Insert handle in pump and stroke.  
platform in or out, it is extremely  
important that the cable-acti-  
vated manual release is positively  
re-engaged to secure (lock) the  
platform carriage assembly before  
loading a passenger on the plat-  
form or before driving the vehicle.  
Grasp the outer barrier and move  
the platform in and out until the  
platform locks (chain release  
assembly engages), securing the  
platform carriage assembly within  
the housing. You will feel the  
release mechanism engage.  
Note: Close valve before operating  
electric pump.  
IN (TO STOW PLATFORM):  
fully extended manually, it does  
not activate the proper switches  
for normal operation. Returning  
(moving) the lift in fully in allows  
for proper switch activation.  
Note: The lift platform must be  
pushed back into its carriage  
compartment all the way before  
reverting back to normal (pow-  
ered) operation. When the lift is  
1. Raise or lower platform to stow level  
(follow UP or DOWN procedures).  
2. Pull T-Handle.  
3. Turn T-Handle to lock platform in re-  
leased position.  
4. Push platform in.  
5. Turn T-Handle.  
6. Push T-Handle in.  
7. Turn T-Handle to lock platform in en-  
gaged position.  
W
A
R
NI  
N
G
Push  
manuaT  
and  
-handle in ful  
lly  
out to  
m
e
o
n
v
g
e
plat  
loc  
Fail  
res  
k
b
ly  
efor  
ure  
and  
a
g
e
f
o
e
l
ock  
dr  
rm in  
to  
u
ivingplatf  
depllt in  
p
un  
orm  
icl  
may  
oymen  
form  
ve  
o
plat  
res  
l
a
i
n
t
h
tf  
ende  
r
m
e
.
t
.
U
n
u
d
d
p
and/oltrinproepl  
i
n
t
l
a
t
se oymenent md aform  
ri  
ou  
e
d
p
s
d
ert  
b
odi  
y
y
ly in  
ama  
g
D
o
n
jur  
e.  
y
o
t
rem  
81  
82  
o
3
ve  
!
Download from Www.Somanuals.com. All Manuals Search And Download.  
Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32553 Rev. A  
Maintenance and Lubrication  
Proper maintenance is necessary to ensure safe, trouble-  
the scheduled “4500 Cy-  
cles” maintenance. These  
intervals are a general  
free operation. Inspecting the lift for any wear, damage  
or other abnormal conditions should be a part of all transit  
agencies’s daily service program. Simple inspections can  
detect potential problems.  
W
ARNING  
Specied (recommended)  
Lubricant  
Available  
Amount  
11 oz.  
Braun  
Lubricant  
Type  
Part No.  
guideline for scheduling  
maintenance procedures  
and will vary according to  
lift use and conditions. Lifts  
exposed to severe condi-  
tions (weather, environ-  
ment, contamination, heavy  
usage, etc.) may require  
inspection and maintenance  
procedures to be performed  
more often than specied.  
Maintenance and lu-  
brication procedures  
must be performed  
as specied by an  
authorized service  
technician.  
Failure to do so may  
result in serious  
bodily injury and/or  
property damage.  
Light Penetrating Oil  
LPS2, General Purpose  
LO - Light Oil  
15807  
15806  
28598  
(30 weight or equivalent)  
Stainless Stick  
Penetrating Oil  
Door-Ease  
Aerosol Can  
1.68 oz.  
The maintenance and lubrication procedures specied in  
the following schedule must be performed by a Braun au-  
thorized service representative at the scheduled intervals  
according to the number of cycles. NHTSA NUVL Series  
lifts are equipped with a cycle counter (digital display built  
into the electronic control board).  
DE - Door-Ease  
Style (tube)  
Stick (tube)  
Synthetic Grease  
(Multipurpose)  
Mobiltemp SHC32  
12.5 oz.  
Tube  
SG - Synthetic Grease  
Outer barrier and lower closure pivot points (2)  
Outer barrier detent pin pivot points (2)  
Inner roll stop hinge pivot points  
Apply Light Oil - See Lubrication Diagram  
Apply Light Oil - See Lubrication Diagram  
Apply Light Oil - See Lubrication Diagram  
Apply Light Oil - See Lubrication Diagram  
Apply Light Oil - See Lubrication Diagram  
NUVL Series lifts are equipped with hardened pins and  
self-lubricating bushings to decrease wear, provide smooth  
operation and extend the service life of the lift.  
Maintenance Indicator:  
The Lift Ready green LED  
mounted on top of the  
pump cover will change color to yellow after every 750 cycles.  
The yellow LED will not affect the functions of the lift, but is a  
reminder to complete necessary maintenance and lubrication.  
When servicing the lift at the recommended intervals,  
inspection and lubrication procedures specied in the pre-  
vious sections should be repeated. Clean the components  
and the surrounding area before applying lubricants.  
LPS2 General Purpose Penetrating Oil is recommended  
where Light Oil is called out. Use of improper lubricants  
can attract dirt or other contaminants which could result in  
wear or damage to the components. Platform components  
exposed to contaminants when lowered to the ground may  
require extra attention.  
Inner roll stop linkage pivot points  
Lifting arm center and platform pivot points (bear-  
ings at all points)  
Once the lift has been serviced, press the CYCLE button  
(located below LCD display on the control board) until the Lift  
Ready LED changes back to green. The CYCLE button also  
clears the lift cycle count (since last service) but not the lifetime  
cycle count.  
Inspect outer barrier and lower closure for proper  
operation  
Correct or replace damaged parts.  
Inspect outer barrier seal and lower closure gasket  
Inspect outer barrier detent pin hairpin cotter  
Resecure, replace or correct as needed  
Ensure hairrpin cotter is present and can be  
removed and inserted easily. Resecure, replace  
or correct as needed.  
Lift components requiring grease are lubricated during as-  
sembly procedures. When replacing these components,  
be sure to apply grease during installation procedures.  
Specied lubricants are available from The Braun Corpora-  
tion (part numbers below).  
Discontinue lift use immediately if maintenance and lubrica-  
tion procedures are not properly performed, or if there is any  
sign of wear, damage or improper operation. Contact your  
sales representative or call The Braun Corporation at 1-800-  
THE LIFT®. One of our national Product Support representa-  
tives will direct you to an authorized service technician who will  
inspect your lift.  
Inspect lift for wear, damage or any abnormal  
condition  
Correct as needed.  
Correct as needed.  
All listed inspection, lubrication and maintenance proce-  
dures should be repeated at “750 cycle” intervals following  
750  
Cycles  
Inspect lift for rattles  
Lubrication Diagram  
Drive Chain and Rollers  
LO  
Check drive chain tension.  
Pull out and lock manual release cable. Adjust  
chain tension as needed. See Drive Chain Adjust-  
ment.  
Drive Chain  
Release Latch  
SG  
Hydraulic  
Cylinder  
Pivot  
Points  
LO  
Eccentric  
Shaft  
Rollers  
(bearings)  
LO  
Resecure, replace or correct as needed. See  
Inner Roll Stop Adjustment Instructions.  
Inspect inner roll stop (bridge plate) and linkage for:  
• Proper operation. Roll stop should rest solidly on  
oor providing smooth transition.  
• Positive securement  
Torque  
Tube  
Pivot  
Points  
LO  
• Wear or damage  
Rolling  
Horizontial  
Carriage Tube  
Slot Area  
DE  
Hydraulic  
Cylinder  
Pivot  
Points  
LO  
Lifting Arm  
Pivot Points  
LO  
Adjust as needed. See Carriage Ride Height  
Adjustment.  
Check carriage ride height in housing  
Check stow height/lifting arm alignment  
LD  
FO  
LD  
UNFO  
UP  
N
Lifting arms should be horizontal, aligned with  
each other and aligned with carriage. Adjust as  
needed. See Switch Adjustment (Below Stow  
Switch).  
Eccentric  
Shaft and  
Carriage  
Rollers  
(bearings)  
LO  
Resecure, replace or correct as needed  
Inspect wiring harnesses for securement, wear or  
other damage  
W
A
R
N
IN  
G
Pu  
mash  
andnu  
T
-h  
a
l
l
y
a
n
d
l
e
l
o
c
o
u
t
m
o
v
i
n
f
ully  
Faik  
b
e
f
t
o
e
n
e
p
l
a
and  
r
e
s
l
u
r
t
o
r
e
g
a
g
e
t
f
o
e
o
dri  
d
e
p
u
l
t
i
n
l
o
c
v
i
n
g
plarm  
v
dedorm cle  
t
f
o
i
n
p
l
a
l
o
y
m
u
nin  
k
pl  
a
t
e
h
i
rm  
r
e
s
t
f
o
rm nt.  
in  
e
t
e
n
f
.
y
a
n
d
u
l
t
d
e
p
l
U
n
i
n
p
l
a
m
a
/or  
s
eri  
o
y
meend  
b
t
tfo  
rm  
nt ed  
ma  
pr  
op  
ou  
e
r
t
y
s
o
d
i
y
D
o
d
a
m
a
l
y
i
n
j
n
o
g
e
.
u
ry  
3
t
r
e
m
8182  
o
v
Resecure, replace damaged parts or correct as  
needed.  
e
!
Check lower pan securement  
Platform Cable-activated  
Manual Release System  
Torque Tube  
Pivot Points  
LO  
Dual Outer  
Barrier (tall)  
Pivot Points  
LO  
Apply Light Oil - See Lubrication Diagram  
Torque tube pivot bearings (4 places)  
Outer Barrier  
Detent Pin  
LO  
Lifting Arm  
Pivot Points  
LO  
Inner Roll Stop  
Inner Roll Stop  
Linkage  
Pivot Points  
LO  
Hinge  
Pivot Points  
and  
Eccentric  
Shaft and  
Carriage  
Rollers  
(bearings)  
LO  
Dual Outer  
Barrier (short)  
and  
Lower Closure  
Pivot Points  
LO  
Inner Roll  
Stop Catch  
LO  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32553 Rev. A  
Maintenance and Lubrication  
Hydraulic Fluid (Pump) - Check level. Note: Fluid  
should be changed if there is visible contamina-  
tion. Inspect the hydraulic system (cylinder, hoses,  
ttings, seals, etc.) for leaks if uid level is low.  
Use 5606 aviation uid only (part 87010R-MILL).  
Check uid level with platform lowered fully.  
Fill to within 1-1/2" of the bottom of the ll tube  
(neck).  
Carriage and eccentric shaft rollers (bearings)  
Apply Light Oil - See Lubrication Diagram  
Inspect lifting arm bushings and pivot pins for vis-  
ible wear or damage  
Replace if needed.  
Lifting arm slots in rolling horizontial carriage arm  
tubes  
Apply Door Ease - See Lubrication Diagram. Ap-  
ply to the surface area around both slots and wipe  
off e cess  
4500  
Cycles  
Inspect outer barrier pivot pin mounting bolts (2)  
Mounting  
ighten or replace if needed  
Hydraulic cylinder pivot points (4 per cylinder)  
Drive chain and chain rollers  
Apply Light Oil - See Lubrication Diagram  
Apply Light Oil - See Lubrication Diagram  
Apply Synthetic rease - See Lubrication Diagram  
Check to see that the lift is securely anchored to  
the vehicle and there are no loose bolts, broken  
welds, or stress fractures.  
Drive chain release latch mechanism  
ecals and ntiskid  
Replace decals if worn, missing or illegible.  
Replace antiskid if worn or missing.  
Deploy lift, remove inboard and outboard lower  
pans and blow out housing. Blow off platform also.  
Use compressor and nozzle to remove all debris  
from housing. Clean outboard lower pan slot and  
apply Antisieze to slot before reinstalling pan.  
Consecutive  
750 Cycle  
Intervals  
Repeat all previously listed inspection, lubrica-  
tion and maintenance procedures at 750 cycle  
intervals.  
Deploy lift, remove inboard and outboard lower  
pans and clean housing tracks  
Use clean cloth and solvent to clean tracks. Clean  
lower pan slot and apply Antisieze to slot before  
reinstalling pan.  
Adjustments and Calibration  
Calibration Procedures  
Check drive chain tensioner, jam nuts and connect-  
ing link for securement and/or misalignment.  
Correct or replace damaged parts and/or relubri-  
cate. See Drive Chain Adjustment.  
Adjustment Procedures  
Platform Sense Calibration  
Lift Out Switch: The Lift Out Switch stops inward travel of  
the carriage/platform during Stow function (activated by the  
housing-mounted Lift Out Cam). Move cam in to increase  
inward travel. Move cam out to decrease inward travel. LED  
D25 will be illuminated when the switch is not contacting the  
cam.  
Correct or replace damaged parts and/or relubri-  
cate.  
Inspect drive chain release latch mechanism for  
proper operation, positive securement, wear or  
other damage  
1. There must be no weight on platform.  
2. Press hand-held pendant UP switch to raise platform a  
minimum "above stow level.  
.Remove pump cover and press and hold control board  
mounted CAL. 50 lb. button. hi le pressing the CAL. 50  
lb. button, press and hold the hand-held pendant STO  
switch (button). The platform will lower to stow level (begin  
stow function), and then start to raise. Release CAL. 50 lb.  
button immediately when platform starts to raise from stow  
level.  
1500  
Cycles  
Ensure T-handle release and cable assembly  
operate properly (see Manual Operation). Ensure  
carriage can be manually e tended and retracted  
freely.  
Inspect platform cable-activated manual release  
system (T-handle/cable assembly and carriage  
movement)  
Full Out Switch: The Full Out Switch stops outward travel of  
the carriage/platform during Deploy (Up/Down) functions (ac-  
tivated by the housing-mounted Full Out Cam). Move cam  
in to decrease outward travel. Move cam out to increase  
outward travel. Carriage rollers must be inside housing a  
minimum 1/2". The platform will not raise or lower until this  
switch is activated. LED D26 will be illuminated when the  
switch is contacting the cam.  
Resecure, replace or adjust as needed. See  
Switch Adjustment.  
Inspect limit switches for securement and proper  
adjustment  
4. LED D18 will be illuminated when weight on plat  
form prevents stowing.  
Correct, replace damaged parts and/or relubricate.  
Inspect carriage, lifting arm and eccentric shaft  
rollers (bearings) for wear or damage, positive  
securement and proper operation  
Ground Sense Calibration  
1. Press hand-held pendant DO  
fully to ground level.  
2. hi le continuing to press the pendant DO  
and then release control board mounted CALIB.  
SE /OB button.  
.Release the pendant DO  
4. LED D2 will be illuminated when platform is at ground  
level.  
switch to lower platform  
switch, press  
Floor Level Switch: LED D28 will be illuminated when the  
switch is contacting the cam. Detailed on reverse side.  
Resecure, replace or correct as needed.  
Inspect e ternal snap rings (e-clips)  
• Carriage roller bearings (4)  
• Lower lifting arm pins (5)  
D
Below Stow Switch: The Below Stow Switch controls the  
height of the carriage/platform before it moves inward during  
the Stow function (activated by the torque tube-mounted  
Below Stow Cam). Rotate the cam in to decrease platform  
height. Rotate the cam out to increase platform height.  
Adjust cam so lifting arms are aligned. iew the platform  
position in the housing. LED D24 will be illuminated at stow  
level and below.  
• Eccentric shaft track roller bearing (1)  
switch.  
Resecure, replace damaged parts, lubricate or  
correct as needed.  
Inspect lower lifting arm pins for wear or damage,  
positive securement and proper adjustment  
Outer Barrier Occupied Calibration  
1. Press hand-held pendant DO  
fully to ground level.  
2. Once outer barrier is fully unfolded (ramp position), release  
the pendant DO switch.  
.Press and hold the control board mounted CALIB.  
SE /OB button. hi le holding CALIB. D SE /OB button,  
press hand-held pendant UP switch to raise the outer bar-  
rier. Be sure to release CALIB. D SE /OB button when  
Resecure, replace damaged parts, lubricate or  
correct as needed. See Carriage Ride Height  
Adjustment.  
Inspect eccentric shaft pins, bearing mounting  
screw, washers and securement hardware for  
wear or damage, positive securement and proper  
operation  
switch to lower platform  
Barrier Down Switch: This platform-mounted switch pro-  
hibits the platform from raising unless the outer barrier is in  
the full up position. The Up function is prohibited if the outer  
barrier detent pin is not fully engaged also. LED D2 wil be  
illuminated when the switch is not contacting the outer barrier  
detent pin.  
D
Resecure, replace or correct as needed.  
Resecure, replace or correct as needed.  
Tighten, repair or replace if needed.  
Resecure, repair or replace if needed.  
Inspect torque tube cams for securement, wear or  
damage  
Inspect housing cam brackets for securement,  
wear or damage  
outer barrier reaches appro imately half full up (vertical)  
position.  
Drive Chain Adjustment  
Inspect cylinder(s), hoses, ttings and hydraulic  
connections for wear, damage or leaks  
Carriage Ride Height Adjustment  
The carriage horizontal arms move (roll) in and out of the  
housing tracks on roller bearings. Following installation or  
In event the drive chain sags 1/2" or more, adjust tension  
as detailed. Tighten to eliminate visible sag but do not  
overtighten.  
Inspect power cable  
e
tensive lift operation, clearance between horizontal arms  
and tracks may diminish. The eccentric shaft mounting plate  
allows height adjustment.  
1. Remove bottom pan.  
2. Pull the manual release cable and lock.  
.Remove adjustment bolt (tensioner) access cover.  
4. Loosen inside jam nut. Secure tensioner and tighten  
outside jam nut. Tighten to eliminate visible chain sag but  
do not overtighten.  
5. Lock jam nuts together making sure the tensioner roller is  
horizontial. Release and push the manual cable in fully.  
Ensure platform is locked by moving the platform in and  
out until chain release assembly engages chain.  
Remove eccentric plate mounting screw. Using screwdriver  
or small rod, rotate the shaft clockwise to increase carriage  
height. Rotate the shaft counterclockwise to decrease carriage  
height. Reinstall mounting screw in nearest retainer hole.  
Adjust left and right side eccentric shafts (screw positions may  
vary from side to side). Adjust height such that horizontal arms  
do not contact top or bottom of tracks (align center).  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Network Card LMC200A 2PS DC User Manual
Black Decker Coffeemaker BCM40B User Manual
Bogen Speaker System AE 5 User Manual
Bosch Appliances Dishwasher SHU53E User Manual
Bowers Wilkins Headphones C5 User Manual
Canon Digital Camera 500 HS User Manual
Carrier Furnace 58MEC User Manual
Centro Gas Grill 07012009 User Manual
CFM Ventilation Hood RMD 0807 User Manual
Chromalox Electric Heater PD441 1 User Manual