Bionaire Air Cleaner BAP825 User Manual

9 9 % HEPA air c leaners  
MODEL BAP825  
Read instructions before operating. Retain for future reference.  
Instruction Leaflet  
IN FO-LIN E  
If after having read this leaflet, you have any  
questions or com m ents on your air cleaner,  
call 1-8 0 0 -7 8 8 -5 3 5 0 in North Am erica.  
428-1137  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING: To reduce the risk of fire or electric shock, DO  
NOT use this air purifier with any solid-state speed control device.  
• DO NOT place anything on top of unit.  
• The ionizer may cause a static charge to build up on the air  
output grill. A static-charged electric shock may be felt if the  
unit is not properly grounded. To avoid a shock, plug the unit's  
three-prong plug into a grounded outlet, or properly install a  
ground adaptor as described in this manual. The shock will  
not occur if the ionizer is off.  
Negative ions help the air purification process by attaching  
themselves to very small airborne particles in the room. These  
particles take on a negative charge and may join with positively  
charged particles such as dust, pollen, smoke and pet dander to  
form larger particles that are then more readily captured by the  
filter system, or they may be attracted to positively charged  
surfaces like walls or floors.  
You may also note after extended use, that dust may have  
collected around the grills or front panel. This is from the  
ionization affect caused by the negative ions exiting from the air  
outlet. This is additional evidence of the air cleaning  
effectiveness of negative ions. The dust can be easily removed  
with a clean, damp cloth or soft brush.  
PLEASE READ AND SAVE  
THESE IMPORTANT  
NOTE: It is important to replace the HEPA filter at the  
recommended intervals. Using the ionizer in conjunction with  
dirty filters may result in dirty particles exiting the air purifier and  
being attracted to walls, carpets, furniture or other household  
objects. These dirty particles may prove very difficult to remove.  
SAFETY INSTRUCTIONS  
CONSUMER SAFETY INFORMATION  
THIS PRODUCT IS EQUIPPED WITH  
A 3-PRONG PLUG. This product is  
for use on 120 volts. The cord has a  
PRE-OPERATING INSTRUCTIONS  
plug (A) as shown. An adapter (C) is  
available for connecting three-blade  
grounding-type plugs to two-slot  
receptacles (B). The green grounding  
1. Carefully unpack your Air Purifier. Select a firm level place  
where there are no obstructions to the air inlet or filtered air  
outlet. A good location in a room is approximately 1 foot away  
from the wall, in a central location of your home.  
lug extending from the adapter must be connected to a  
permanent ground such as a properly grounded outlet box. The  
adapter should not be used if a three-slot grounded receptacle  
is available.  
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS  
POLARIZED PLUG IN ANY WAY.  
2. Pull air inlet grill towards you by grasping the finger tabs on  
both sides.  
3. Remove HEPA filter by gripping on both sides and pulling forward.  
4. Remove protective plastic bag from the filter cartridge.  
5. This model utilizes a hang tab and filter clip. The clip can only  
be attached to the tabs on the filter one way only. The filter clip  
should easily slide onto the filter hang tab with only a small  
amount of pressure. DO NOT use force while attaching the  
clip to the filter (See Figure 1). Align the clip on the top of the  
HEPA filter with the rails on the inside of the air purifier unit.  
Gently slide the filter onto the rail (See Figure 2).  
CORD AND PLUG INSTALLATION SAFETY INSTRUCTIONS  
The length of cord used on this appliance was selected to  
reduce the hazards of becoming tangled in, or tripping over a  
longer cord. If a longer cord is necessary, an approved extension  
cord may be used. The electrical rating of the extension cord  
must be equal to or greater than the rating of the air purifier. Care  
must be taken to arrange the extension cord so that it will not  
drape over the countertop or tabletop where it can be pulled on  
by children or accidentally tripped over.  
NOTE: The side with the soft gasket should face inward.  
6. Replace air inlet grill back onto unit securely.  
DO NOT POINT AIR OUTLET TOWARDS WALL.  
Thank you for choosing a Bionaire® air purifier. To ensure the  
best performance from your air purifier, please read and save the  
following instructions.  
Figure 2  
Figure 1  
IONIZER  
Your Air Purifier has an independently controlled ionizer, which,  
when turned on, releases negative ions into outgoing filtered air.  
Ions are tiny particles that carry a positive or negative charge.  
These ions exist naturally around us, in the air, water and  
ground. Both positive and negative ions are colorless, odorless  
and completely harmless.  
3
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Set tower air purifier on a dry, level surface.  
2. Plug cord into any standard 120V AC outlet.  
3. To turn the air purifier on, press the power button (  
then select the desired operating speed by pressing any  
speed button on the remote control or on the control panel.  
OPERATING INSTRUCTIONS  
1. Plug into a 120V AC electrical outlet.  
) and  
2. Press the power button (  
). The unit will turn onto high and  
the power light will illuminate letting you know the power is on.  
3. You can then select the desired speed setting. This air purifier  
has three speed settings. You can select from HIGH ( ),  
MEDIUM ( ), or LOW ( ) by pushing the desired operating  
speed button on the control panel or the remote control.  
4. To release negative ions into the filtered air, press the ionizer  
button ( ) to ON and the light will illuminate.  
5. For optimum air filtration, it is recommended to operate the air  
purifier continuously. Its rugged motor has been designed to  
give many years of use.  
4. The speed is adjustable by pressing either the Speed Button  
on the remote control or on the control panel.  
5. To turn the unit off, press the off button (  
remote control or on the control panel.  
) on either the  
6. To start and stop oscillation of the air purifier, push the button  
identified as Oscillation ( ) on the remote control or control panel.  
CLEANING/MAINTENANCE INSTRUCTIONS  
For continuous use, it’s recommended to operate the air purifier at  
the MEDIUM setting. For quieter operation or use in a bedroom,  
select the LOW setting. When high levels of air pollution are present,  
select the HI setting to quickly circulate and filter the room air.  
Turn off and unplug the unit before cleaning.  
1. The outside of the air purifier can be cleaned with a soft, damp cloth.  
2. The rear air inlet grill can be removed and washed in warm soapy  
water (not dishwasher safe). Dry before replacing in the unit.  
D
C
I
F
G
H
Figure 3  
3. The front air outlet grill can be cleaned of dust with a small soft brush.  
WARNING: Do not allow moisture to come in contact with the  
main housing of the air purifier.  
A
B
FILTER REPLACEMENT INSTRUCTIONS  
1. Filter Life Indicator – Your air purifier has an indicator light that  
illuminates when it is time to change the filter.  
E
2. Every few weeks, check the condition of the filters.  
3. Remove the air inlet grill. Remove and examine the foam pre-filter. If  
it has collected a noticeable amount of dust or lint, remove it from  
the inlet of the grill and wash it in warm soapy water. Rinse and drip  
dry the pre-filter thoroughly before replacing it into the inlet of the grill.  
J
4. With the inlet grill removed, check the condition of the HEPA  
filters. If the filters are dirty, remove the used HEPA cartridge  
and properly dispose of it. DO NOT try to wash and re-use the  
HEPA filters. Replace with new HEPA filters, removing the  
protective polybag before inserting into the air purifier.  
A.INLET GRILL  
B.WASHABLE FOAM  
PRE-FILTER  
F. FILTER INDICATOR LIGHT  
G.IONIZER CONTROL  
H.IONIZER LIGHT  
NOTE: The side with the soft gasket should face inward.  
C.SPEED CONTROL  
D.POWER INDICATOR  
E.FILTERED AIR OUTLET  
I. OSCILLATION BUTTON  
J. HEPA/CARBON FILTER  
5. The unit must be reset once the HEPA filters have been  
replaced. Reset the indicator by pressing the power button (  
on the control panel for 2 seconds.  
)
6. Filter Life – Under normal conditions of continuous use, the  
HEPA filters will operate efficiently for 3-6 months.  
Replacement filters are available from your local supplier or by  
calling 1-800-788-5350.  
REMOTE CONTROL & OSCILLATION  
Your remote control requires (2) AAA batteries for operation. To  
install the batteries, simply depress and slide the back of the  
remote control with your thumb on the arrow indentation. Insert  
batteries according to the diagram shown inside and replace cover.  
Air Purifier  
Model #  
Filter Quantity  
Needed  
Filter #  
Filter  
Description  
• Do NOT mix old and new batteries.  
• DO NOT mix alkaline, standard (carbon-zinc) or rechargeable  
BAPF30  
BAP825-U  
2
HEPA/Carbon  
(nickel-cadmium) batteries.  
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
WARRANTY  
Bionaire® warrants to the first retail purchaser, for TWO (2) YEARS  
from the date of original purchase, either to repair or replace at its  
option, without charge (parts and labor), any supplied or  
manufactured part of this air purifier which, upon inspection by an  
authorized service center, proves to have failed in normal use due to  
defects in material or workmanship, or at its option, to replace the  
unit.  
PROBLEM  
SOLUTION  
Unit will not operate • Check to make sure the unit is plugged in.  
• Check to make sure the unit is on by pressing  
the power button.  
Operation under conditions other than those recommended or  
at voltages other than the voltage indicated on the unit, or any  
attempts by unauthorized personnel to service the unit or  
modify it, will render the guarantee void.  
Bionaire® shall not be liable for any personal injury, property  
damage or any incidental or consequential damages of any kind  
(including water damage), resulting from defects, malfunctions,  
misuse, improper installation or alteration of the product.  
Decreased airflow • If the Filter Life Indicator is red, the HEPA  
filters need to be changed.  
• If the filters have not been changed in six  
months or more, change the HEPA filters.  
• Check the filters to make sure they are in  
good condition.  
BIONAIRE® EXPRESSLY DISCLAIMS ALL RESPONSIBILITY  
FOR CONSEQUENTIAL DAMAGES OR INCIDENTAL LOSSES  
CAUSED BY USE OF THIS PRODUCT.  
• Check to ensure nothing is blocking air inlet  
and filtered air outlet.  
The provisions of this Warranty are in addition to, and not a modification  
of, or subtraction from the statutory warranties and other rights and  
remedies contained in any applicable legislation and to the extent that  
any such provision purports to disclaim, exclude or limit any such  
statutory warranties or other rights or remedies, such provisions shall be  
deemed to be amended to the extent necessary to comply therewith.  
For Warranty Service, please call 1-800-788-5350 in North America.  
A Bionaire® consumer service representative will help determine which  
is the best procedure in order for your air purifier to be repaired.  
AIR PURIFIER SERVICE INSTRUCTIONS  
1. Do NOT attempt to repair or adjust any electrical or  
mechanical functions on this unit. Doing so will void the  
warranty. The inside of the unit contains no user serviceable  
parts. All servicing should be performed by qualified  
personnel only.  
2. If you need to exchange the unit, please return it in its original  
carton, with a sales receipt, to the store where you purchased  
it. If you are returning the unit more than 30 days after the  
date of purchase, please see the enclosed warranty.  
KEEP THIS NUMBER FOR FUTURE REFERENCE.  
3. Should your Air Purifier require service, please call  
1-800-253-2764 in North America for further assistance.  
4.  
If you have any other questions or comments, feel free to  
write to us:  
Consumer Service Department  
32B Spur Drive  
El Paso, TX 79906  
Bionaire® is a registered trademark of The Holmes Group, Inc.  
BAP82503EM2  
6
Bionaire logo is a trademark of The Holmes Group, Inc.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

Blackberry Cell Phone Pearl User Manual
Bogen Microphone MIC2S User Manual
Bosch Power Tools Drill 11250VSRD User Manual
Braun Food Processor K 700 User Manual
Bryant Furnace 373LAV User Manual
Bushnell Hunting Equipment 205110 User Manual
Casio Digital Camera EX S100 User Manual
Chicago Electric Power Hammer 68696 User Manual
Chicago Electric Work Light 30858 User Manual
Chicco Baby Toy DUCATI 1198 RC User Manual