INSTALLATION INSTRUCTIONS
HB0061
UP27I and UP27E SERIES
!
!
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE AND OPERATION INFORMATION ON
PAGES 13 AND 14.
In USA - BEST BY BROAN® P.O. Box 140, Hartford, WI 53027
In Canada - BEST BY BROAN® 550 Lemire Blvd., Drummondville, QC, J2C 7W9
V07855 rev. A
Download from Www.Somanuals.com. All Manuals Search And Download.
- UP27I SERIES RANGE HOOD SYSTEM -
INTERIOR BLOWER
Model 634 or 644
(roof cap)
Model 647
(7” Round wall cap)
Model 634 or 644
(roof cap)
Model 643
(8” Round wall cap)
Model 418
8” round
adjustable
elbow,
Model 415
(7” round
adjustable
elbow,
Model 459
transition
3¼” x 14”
to 8” round
(optional)
optional)
Model 407
(7” round duct
2 ft. sections)
8” round
standard
duct
Model 412
transition
3¼” x 10”
to 7” round
3¼” x 14”
rectangular
standard duct
3¼” x 10”
rectangular
standard duct
Model 459 transition
3¼” x 14” to 8” round
Model T460 transition
3¼” x 14” to 7” round
Adapter/damper 3¼” x 14”
(supplied with hood)
Adapter/damper
3¼” x 14” to 3¼” x 10”
(supplied with hood)
Left and right flow
deviators (supplied
with hood)
NON-DUCT KIT FLUE
ANKUP SERIES
UP27I SERIES
HOOD
(Canopy with internal
blower, controls &
lighting. Required for
all installations.)
HL0086
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
- UP27E SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
Model 441
Model 437
Model ILB9 (800 cfm)
(10” Round wall cap)
(High capacity roof cap)
Model EB12 (1200 cfm)
or EB15 (1500 cfm)
exterior blower
or ILB11 (1100 cfm)
in-line blower
Model EB6 (600 cfm)
or EB9(900 cfm)
exterior blower
(includes two 8” x 12” to
10’’ round transitions)
Model 441
(10” Round
wall cap)
Model ILB6 (600 cfm)
in-line blower
(includes two 4½” x 18½”
to 10’’ round transitions)
Model 421
Model 418
10” Round
adjustable elbow
(optional)
(10” Round vert.
in-line damper)
Recommended
for use with
Model ILB3 (280 cfm)
in-line blower
(includes one 8” to 10”
round transition)
exterior blowers
Model 410
(10” Round duct
—2ft. sections)
UP27E SERIES
HOOD
(Canopy with
controls & lighting.
Required for all
installations.)
HL0087
In-line and exterior blower rough-in kit
(included with EB6, EB9, EB12, EB15,
ILB3, ILB6, ILB9 and ILB11 blowers.)
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
1. SELECT BLOWER OPTION AND INSTALLATION TYPE
1.1 NON-DUCTED INSTALLATION (ONLY FOR UP27I SERIES HOODS)
The non-duct kit ANKUP Series (sold separately) must be installed. This kit fits hood from 30-inch width up to 48-inch
width. See installation instructions included with the non-duct kit ANKUP Series.
1.2 DUCTED INSTALLATION
Either UP27I or UP27E Series range hoods may be ducted. For a UP27E Series range hood, either an exterior blower or
in-line blower may be used. The Best by Broan UP27E Series must be installed with blower models ILB3, ILB6, ILB9,
ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers sold separately.)
Plan where and how the ductwork will be installed.
NOTE: There is no horizontal exhaust on UP27E Series range hood.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 3, 5 up to 10,
and 12 and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use metal duct tape to
seal duct joints.
1.3 ALL INSTALLATIONS
The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly
recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users discretion.
ROOF CAP
ROOF CAP
3¼” x 10”
or 3¼” x 14” DUCT
(83 mm x 254 mm or
83 mm x 356 mm)
7” OR 8” ROUND DUCT
(178 mm or 203 mm)
CABINET
CABINET
7” OR 8”
ROUND ELBOW
(178 mm or 203 mm)
WALL CAP
WALL CAP
3¼” x 10” or
3¼” x 14” ELBOW
(83 mm x 254 mm or
83 mm x 356 mm)
3¼” x 14” to 7” OR
HOOD
HOOD
3¼” x 14” to 8”
ROUND TRANSITION
(83 mm x 356 mm to 178 mm
or 83 mm x 356 mm to 203 mm)
(see page 3)
24” TO 30”
24” TO 30”
(609 mm to 762 mm)
(609 mm to 762 mm)
ABOVE COOKING SURFACE
ABOVE COOKING SURFACE
HH0076A
HH0077A
UP27I (DUAL INTERIOR BLOWER)
TYPICAL RECTANGULAR DUCTWORK
UP27I (DUAL INTERIOR BLOWER)
TYPICAL ROUND DUCTWORK
EXTERIOR
BLOWER
ROOF CAP
10” (254 mm)
ROUND DUCT
10” (254 mm)
ROUND DUCT
IN-LINE BLOWER
CABINET
EXTERIOR
BLOWER
10” (254 mm)
ROUND ELBOW
WALL
CAP
HOOD
HOOD
24” TO 30”
(609 mm to 762 mm)
ABOVE COOKING SURFACE
24” TO 30” (609 to 762 mm)
ABOVE COOKING SURFACE
HH0078A
HH0079A
UP27E WITH MODEL EB6, EB9, EB12 OR EB15
EXTERIOR BLOWER TYPICAL DUCTWORK
UP27E WITH MODEL ILB3, ILB6, ILB9 OR ILB11
IN-LINE BLOWER TYPICAL DUCTWORK
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
2. PREPARE THE INSTALLATION
CAUTION
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and
gloves.
Remove the installation kit from inside the hood.
Make sure that the following items are included:
- Installation manual
- Adapter/damper 3¼” x 14” to 3¼” x 10” (exclusively for UP27I Series range hoods, temporarily assembled to pan, behind
Evolutionary™ hybrid baffle filters)
- Adapter/damper 3¼” x 14” (exclusively for UP27I Series range hoods, temporarily assembled to pan, behind Evolutionary™
hybrid baffle filters)
- Right and left flow deviators (exclusively for UP27I Series range hoods)
- Accessories including:
• 3 Evolutionary™ hybrid baffle filters
• Shielded halogen lights (GU10 type base, 120 V, 50 W) (2 for hoods up to 36” width, 4 for hoods from 42” to 48” width)
• Bag of parts including:
(4) no. 10-32 lock nuts, (1) electrical cable clamp, (8) no. 8 x 1/2” double thread screws, (2) wire connectors,
(2) no. 6 x 1/2” standard screws, (6) no.8 x 3/8” screws.
Parts sold separately:
- In-line blower assembly ILB3, ILB6, ILB9 or ILB11 (all include transition and rough-in plate, exclusively for UP27E Series range hoods)
- Exterior blower assembly EB6, EB9, EB12 or EB15 (all include rough-in plate, exclusively for UP27E Series range hoods)
- Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options and model
numbers
- Non-duct kit ANKUP Series, mandatory for non-ducted installation (exclusively for UP27I Series range hoods).
3. REMOVE THE FILTERS
Remove tape on baffle filters.
1
2
Remove baffle filters from hood by pushing them towards
the front of hood (1) and rotating downward (2).
Set aside filters.
NOTE: It is recommended to start with the central one.
HD0206
4. REMOVE BOTH ADAPTER/DAMPERS (UP27I SERIES RANGE HOODS ONLY)
ADAPTER/DAMPERS RETAINING
Disassemble both adapter/dampers (shaded parts on illustration beside) from
hood pan by removing their retaining screws (2 screws per adapter and
SCREWS LOCATION
damper). Discard the screws.
HD0211
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
5. REMOVE THE GREASE DRIP RAIL
Remove tape on grease drip rail. Lift out grease drip rail and set aside.
HD0212
6. REMOVE THE PAN
Using a Phillips no. 2 screwdriver, remove the screws retaining the pan (shaded parts on illustration below) to the hood. Remove
the pan and set aside.
NOTE: There are 2 screw models for UP27I pan retaining screws; the flat end type (A) (n°. 8 x 3/8”) are shorter and located
near the front of the hood and the pointed end ones (B) (n°. 6 x 1/2”) are longer located in the middle of the hood. UP27E
pan retaining screws are all the same.
UP27I RETAINING SCREWS LOCATION
UP27E RETAINING SCREWS LOCATION
A
A
A
A
A
A
A
A
B
B
B
A: no. 8 x 3/8”
B: no. 6 x 1/2”
A: no. 8 x 3/8”
HD0207
7. PREPARE THE CABINET
For cabinets with recessed bottom, attach two wood filler strips cut to length (not included), on each side, as shown below. See
table below for wood filler strips location.
HOOD
WIDTHS
30”
36”
42”
CENTER OF WOOD
STRIP LOCATION (A)
13 3⁄8
16 3⁄8
19 3⁄8
22 3⁄8
”
”
”
”
C
L
A
A
48”
HD0208
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
7. PREPARE THE CABINET (CONT’D)
7.1 DUCTED INSTALLATION:
36”, 42” OR 48” INTERNAL BLOWER HOOD
CABINET BOTTOM
30” INTERNAL BLOWER HOOD
Cut-out the openings for
duct (A) and house
wiring (120 V AC)(B)
according to the direction
of discharge chosen.
See figures beside.
CABINET BOTTOM
C
L
C
L
13”
A
14”
A
NOTE: For all UP27I Series
B
(internal
blower)
Ø 1¼”
¾”
B
3¾”
3¾”
range hoods, the
cut-out opening for
house wiring (120V AC)
can be made in cabinet
bottom OR wall, no
matter the discharge
chosen (horizontal or
vertical).
2”
7¼”
7¼”
7¼”
7¼”
2”
½”
½”
30” INTERNAL BLOWER HOOD
36”, 42” OR 48” INTERNAL BLOWER HOOD
C
L
C
L
13”
B
14”
2”
A
A
2”
3¼”
B
3¾”
3¾”
7¼” 7¼”
7¼” 7¼”
Ø 1¼”
HOOD WITH IN-LINE OR EXTERIOR BLOWER
CABINET BOTTOM
3¼”
B
A
C
45
8
”
L
10³
8
”
6¼”
Ø 10”
95
8
”
HD0200A
5”
7.2 NON-DUCTED INSTALLATION: NON-DUCT KIT FLUE ANKUP SERIES
(ONLY FOR UP27I SERIES RANGE HOODS)
Refer to the installation sheet included with the non-duct kit for details.
8. PREPARE THE HOOD
8.1 UP27I SERIES RANGE HOOD (INTERNAL BLOWER)
VERTICAL DISCHARGE
TOP OF HOOD
Seal the metal shut-off plate on the back of the hood using duct tape.
BACK OF HOOD
HD0199
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
8. PREPARE THE HOOD (CONT’D)
8.1 UP27I SERIES RANGE HOOD (INTERNAL BLOWER) (CONT’D)
VERTICAL DISCHARGE (CONT’D)
Using 4 no. 8 x 3/8” screws provided with hood, secure the chosen
adapter/damper to the top of the hood. Remove tape from damper flap.
HD0201
Seal the adapter/damper to the hood using duct tape.
HD0202
HORIZONTAL DISCHARGE (DUCTED INSTALLATION ONLY)
The UP27I Series range hoods are factory set to exhaust vertically. If the
horizontal discharge is chosen, remove the metal shut-off plate from the
back of the hood, by removing its 3 screws. Set aside the screws. Discard
both left and right flow deviators assembled to the metal shut-off plate.
HD0203
Press the metal shut-off plate on a flat surface to completely flatten bent
flange, and install on top of hood using 3 screws previously removed plus
another no. 8 x 3/8” screw (from parts bag).
HD0119
Fold down the foldable flange of the chosen adapter/damper. This flange
must be at 90° from the remaining flanges. See picture beside.
HO0112
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
8. PREPARE THE HOOD (CONT’D)
8.1 UP27I SERIES RANGE HOOD (INTERNAL BLOWER) (CONT’D)
HORIZONTAL DISCHARGE (DUCTED INSTALLATION ONLY)(CONT’D)
TOP OF HOOD
Using 3 no. 8 x 3/8” screws provided with hood, secure the adapter/damper
on the back of the hood. Remove tape from damper flap.
ADAPTER/DAMPER
SCREW LOCATION
BACK OF HOOD
HD0204
Seal the adapter/damper and the metal shut-off plate to the hood using
duct tape.
HD0205
8.2 UP27E SERIES RANGE HOOD (EXTERIOR OR IN-LINE BLOWER)
WIRING COVER
Run house wiring (120 V AC) to installation location. Refer to the instructions
included with the selected blower/rough-in kit (sold separately) for details
on installing the rough-in plate. Install the rough-in plate so that the wiring
box is located on the right side as you are facing the hood.
ROUGH-IN PLATE
ON TOP OF HOOD
LOCKNUTS
HD0210
9. CONNECT WIRING
WARNING
!
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all
applicable codes and standards. Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power to be switched on accidentally.
9.1 UP27I SERIES RANGE HOOD (INTERNAL BLOWER)
Run house wiring (120 V AC) to installation location. Place the electrical cable clamp, insert the cable in the hood and
tighten the electrical cable clamp to secure the cable. Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare
wire under GREEN ground screw.
9.2 UP27E SERIES RANGE HOOD (EXTERIOR OR IN-LINE BLOWER)
Remove wiring cover from rough-in plate and set aside.
Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
Reinstall wiring cover on rough-in plate.
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
10.INSTALL THE HOOD
Place the hood at its location. Using a pen, mark the position of the screw (smaller part of the keyholes [A]). Remove the hood
and install (4) 1/2” double thread screws at marked positions, leaving a 1/8” gap.
Place the hood under the cabinet and slide it in position. Make sure the adapter/damper enters the ducting and the damper
opens freely (UP27I Series range hood only), or ensure ducting connects to rough-in plate (UP27E Series range hood only).
Secure the hood by tightening the screws completely. Install the last 1/2” double thread screws in the remaining holes [B].
UP27I HOOD RETAINING SCREWS LOCATION
UP27E HOOD RETAINING SCREWS LOCATION
A
B
A
B
HD0213
11.INSTALL THE BLOWER (EXTERIOR BLOWER, UP27E SERIES RANGE HOOD ONLY)
Refer to instructions included with blower.
Once the blower is installed, plug the blower cord (A) into the female receptacle
and the power supply cord (B) onto the male connector inside the hood.
A
B
WARNING
!
Do not plug the two cords into each other.
HE0078
12.REINSTALL THE PAN
Using a Phillips screwdriver and the pan retaining screws, reinstall the pan (previously removed in step 6) inside the hood (shaded
parts on illustration below).
UP27I RETAINING SCREWS LOCATION
UP27E RETAINING SCREWS LOCATION
A
A
A A
A
A
A
A
B
B
B
A: no. 8 x 3/8”
B: no. 6 x 1/2”
A: no. 8 x 3/8”
HD0207
- 11 -
Download from Www.Somanuals.com. All Manuals Search And Download.
13.REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS
Reinstall the grease drip rail.
HD0214
CAUTION
Remove protective plastic film covering Evolutionary™ hybrid baffle filters before installing them.
13.1 DUCTED INSTALLATION:
Reinstall Evolutionary™ hybrid baffle filters on the hood.
13.2 NON-DUCTED INSTALLATION:
Slide out and discard the secondary micromesh filters from the back of the baffle filters. Slide in the charcoal filters included
in the non-duct kit. Reinstall the baffle filters on the hood.
It is recommended to install side filters first and finish with center one.
1.
Insert one end of Evolutionary™ hybrid baffle filter
into the front channel of the hood.
1
2
2.
Raise the other end toward the inside of hood and
insert in the grease drip rail of the hood.
Replacement filters are available from your dealer. See
label inside hood for size and part number.
For charcoal filter replacement kit, see table on pages 15
and 16.
HD0209
14.LIGHT BULBS REPLACEMENT
WARNING
!
In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed
fixtures.
This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).
WARNING
!
In order to prevent the risk of personal injury, the halogen lamps must be cooled down before removing
them.
1
2
3
1. To remove lamps, gently push upwards and turn counterclockwise
to disengage bulb leads from their grooves.
NOTE: If need be, use a rubber dishwashing glove to add grip
when removing the bulb.
2. Install the new lamps by placing the bulb leads into their
grooves in the socket.
3. Gently push upwards and turn clockwise until secure.
HO0089
- 12 -
Download from Www.Somanuals.com. All Manuals Search And Download.
15.USE AND CARE
Evolutionary™ Hybrid Baffle Filters
The Evolutionary™ hybrid baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your
cooking style generates greater grease—like frying foods or wok cooking.
Remove Evolutionary™ hybrid baffle filters by pushing them towards the front of hood and rotating filters downward. Slide out
the secondary micromesh filter from the back of each hybrid baffle filter before cleaning. Baffle filters are dishwasher safe. Clean
secondary filters with a warm detergent solution. Allow filters to dry completely before reinstalling them in the hood.
CAUTION
Never attempt to wash the carbon filters in the non-duct kit. Those filters must be replaced by new ones.
Refer to the non-duct kit installation instructions for details.
Grease Drip Rail
The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle
filters, wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Allow grease drip rail
to dry completely before reinstalling it in the hood.
Blower Cleaning
INTERIOR BLOWER
Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water.
EXTERIOR OR IN-LINE BLOWER
Refer to blower instruction manual for more details.
Hood Cleaning
Stainless steel cleaning: How to maintain its “BRIGHT LOOK”
Do:
• Regularly wash with clean cloth or rag soaked with warm
Don’t:
• Do not use any steel or stainless steel wool or any other
water and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after
cleaning. Wipe dry completely.
• You may also use a specialized household stainless steel
cleaner.
scrapers to remove stubborn dirt.
• Do not use any harsh or abrasive cleansers.
• Do not allow dirt to accumulate.
• Do not let plaster dust or any other construction residues
reach the hood. During construction/renovation, cover the
hood to make sure no dust sticks to stainless steel surface.
Avoid: When choosing a detergent
• Any cleaners that contain bleach will attack stainless steel.
• Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
• Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should
never be used close to a range.
16.OPERATION
Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few
minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
2
1
3
4
HC0030
1. ON/OFF Blower switch
2. Blower speed control
3. ON/OFF Halogen light switch
4. Light intensity control
Blower
The blower is operated using two (2) controls.
Use the ON/OFF toggle switch (item 1 on picture above) to start and stop the blower. When turned on, the blower will operate
at the previous setting of the speed control (item 2 on picture above).
Turn the speed control knob counterclockwise to increase blower speed—clockwise to decrease speed.
- 13 -
Download from Www.Somanuals.com. All Manuals Search And Download.
16.OPERATION (CONT’D)
HEAT SENTRY
Both UP27I and UP27E series are equipped with a HEAT SENTRY thermostat.
• If blower is ON at a lower speed setting and excessive heat is detected above the cooking surface, it turns the blower up to
HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.
• If blower is OFF and excessive heat is detected above the cooking surface, HEAT SENTRY will turn the blower to HIGH
speed. When the temperature level drops to normal, the blower turns back OFF.
WARNING
!
The HEAT SENTRY can start the blower even if the hood is turned OFF. In this case, it is impossible to turn
the blower OFF with blower switch. To stop the blower on UP27I series, the main power switch located
behind the baffle filters must be in the “OFF” position. As for UP27E series, disconnect the power supply
cord from the male hood connector. See illustrations below.
UP27I SERIES
UP27E SERIES
POWER
SUPPLY
CORD
HE0078
MAIN
POWER
SWITCH
HD0215
Cooktop Lighting (Halogen)
The halogen lighting is controlled by two switches; one ON/OFF switch and one light intensity control switch.
When turned on, the halogen bulbs will light cooktop at the previous setting of the light intensity control.
Turn the light intensity control knob counterclockwise to increase lighting—clockwise to decrease lighting.
Use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).
WARRANTY
BROAN ONE-YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials
or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to
be defective under normal use and service.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to
misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary
to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or
provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND
EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTIONWITH PRODUCT USE OR PERFORMANCE. Some states
or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province
to another. Any modification performed on this product without the authorization of Broan will void this warranty. This warranty
supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan at the address or telephone number stated below, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty
service, you must present evidence of the original purchase date.
®
®
Best by Broan , P.O. Box 140, Hartford, WI 53027 USA (1-800-637-1453)
Best by Broan , 550 Lemire Blvd., Drummondville, QC J2C 7W9 CANADA (1-866-737-7770)
- 14 -
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE PARTS
UP27I MODEL
2
1
23
22
4
5
6
3
10
13
21
20
7
8
11
12
19
16
18
9
15
14
17
HL0088
KEY
PART
QTY (HOOD WIDTH)
30’’ 36’’ 42’’ 48
NO. NUMBER DESCRIPTION
1
2
3
4
5
6
7
8
9
V14971 ADAPTER/DAMPER 3¼” X 14”
1
1
1
2
2
1
2
2
2
2
2
1
1
1
1
3
-
3
-
1
-
-
-
1
1
-
-
-
1
1
1
2
2
1
2
2
2
2
2
1
1
1
1
2
1
2
1
-
1
1
1
2
2
1
2
4
4
2
2
1
1
1
1
1
2
1
2
-
1
1
1
2
2
1
2
4
4
2
2
1
1
1
1
-
3
-
3
-
-
-
1
1
-
-
-
T461
ADAPTER/DAMPER 3¼” X 14” TO 3¼” X 10”
THERMISTOR HEAT SENTRY
ROTARY CONTROL
TOGGLE SWITCH
PLASTIC CONTROL FRAME AND KNOB ASS’Y
V03435
V07834
V07689
V16966
V07688 KNOB
V16569 LAMP SHELL, SOCKET AND TRIM ASS’Y
V05921 HALOGEN BULBS (50 W, 120 V, PAR16, GU-10)
10 V02160 CAPACITOR 15 µF
11 V01857 WIRE COVER
12 V01766 MOTOR 165 W CLOCKWISE
13 V03457 MOTOR 165 W COUNTERCLOCKWISE
14 V03399 HOOD BLOWER WHEEL, 7.094” X 3.375”, COUNTERCLOCKWISE
15 V03400 HOOD BLOWER WHEEL, 7.094” X 3.375”, CLOCKWISE
V08070 SECONDARY MICROMESH FILTER 8.84” X 13.35”
V08071 SECONDARY MICROMESH FILTER 14.84” X 13.35”
V17025 EVOLUTIONARY™ HYBRID BAFFLE FILTER 8.95” X 13.5” X 1” (INCL. ITEM 16)
V17026 EVOLUTIONARY™ HYBRID BAFFLE FILTER 14.95” X 13.5” X 1” (INCL. ITEM 16)
V16793 GREASE DRIP RAIL 30”
V16794 GREASE DRIP RAIL 36”
V16795 GREASE DRIP RAIL 42”
V16796 GREASE DRIP RAIL 48”
16
17
1
-
-
1
-
1
-
-
1
-
1
-
-
18
19 V05869
BEST BY BROAN LOGO
V15457 INTERNAL FRAME ASS’Y 30” X 22” X 10” (INCLUDING ITEM 19)
V15458 INTERNAL FRAME ASS’Y 36” X 22” X 10” (INCLUDING ITEM 19)
V15459 INTERNAL FRAME ASS’Y 42” X 22” X 10” (INCLUDING ITEM 19)
V15460 INTERNAL FRAME ASS’Y 48” X 22” X 10” (INCLUDING ITEM 19)
20
1
-
-
1
1
1
1
1
6
1
21 V15512
22 V06242
23 V06243
*
*
*
BACK PLATE
1
1
1
1
6
1
1
1
1
1
6
1
1
1
1
1
6
1
LEFT FLOW DEVIATOR
RIGHT FLOW DEVIATOR
MAIN POWER SWITCH
V03503
V02001 MOTOR GROMMET G-431-1
V07855
INSTALLATION GUIDE
PARTS BAG (ELECTRICAL CABLE CLAMP LP16-AP (1),
V13278 WIRE CONNECTORS NO. 74B (2), DOUBLE THREADED SCREWS 6-12 X 0.5 (6),
SCREWS NO. 8 X 3/8’’ (6), NUTS NO. 10-32 (4), SCREWS NO. 6 X 1/2’’ (2))
*
1
1
1
1
*
*
*
*
V17020
V17021
V17022
V17023
ANKUP CHARCOAL FILTER KIT (INCLUDING 3 CHARCOAL FILTERS)
ANKUP CHARCOAL FILTER KIT (INCLUDING 3 CHARCOAL FILTERS)
ANKUP CHARCOAL FILTER KIT (INCLUDING 3 CHARCOAL FILTERS)
ANKUP CHARCOAL FILTER KIT (INCLUDING 3 CHARCOAL FILTERS)
1
-
-
-
1
-
-
-
1
-
-
-
-
-
-
1
*
NOT SHOWN.
- 15 -
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE PARTS
UP27E MODEL
6
5
7
1
8
2
3
4
14
9
13
10
12
11
HL0089
KEY
PART
QTY (HOOD WIDTH)
30’’ 36’’ 42’’ 48’’
NO. NUMBER DESCRIPTION
1
2
3
4
5
6
7
8
9
V13923
V13924
V03435
FEMALE CONNECTOR
MALE CONNECTOR
THERMISTOR HEAT SENTRY
1
1
1
2
1
2
2
2
2
3
-
3
-
1
-
-
-
1
1
1
2
1
2
2
2
2
2
1
2
1
-
1
-
-
1
-
1
-
1
1
1
2
1
2
2
4
4
1
2
1
2
-
-
1
-
1
-
-
1
1
1
2
1
2
2
4
4
-
3
-
3
-
-
-
1
1
-
-
-
1
1
V07688 KNOB
V16966
V07689
V07834
PLASTIC CONTROL FRAME AND KNOB ASS’Y
TOGGLE SWITCH
ROTARY CONTROL
V16569 LAMP SHELL, SOCKET AND TRIM ASS’Y
V05921 HALOGEN BULBS (50 W, 120 V, PAR16, GU-10)
V08070 SECONDARY MICROMESH FILTER 8.84” X 13.35”
V08071 SECONDARY MICROMESH FILTER 14.84” X 13.35”
V17025 EVOLUTIONARY™ HYBRID BAFFLE FILTER 8.95” X 13.5” X 1” (INCL. ITEM 10)
V17026 EVOLUTIONARY™ HYBRID BAFFLE FILTER 14.95” X 13.5” X 1” (INCL. ITEM 10)
V16793 GREASE DRIP RAIL 30”
V16794 GREASE DRIP RAIL 36”
V16795 GREASE DRIP RAIL 42”
V16796 GREASE DRIP RAIL 48”
10
11
12
13 V05869
BEST BY BROAN LOGO
1
1
-
-
-
V15461 INTERNAL FRAME ASS’Y 30” X 22” X 10” (INCLUDING ITEM 13)
V15462 INTERNAL FRAME ASS’Y 36” X 22” X 10” (INCLUDING ITEM 13)
V15463 INTERNAL FRAME ASS’Y 42” X 22” X 10” (INCLUDING ITEM 13)
V15464 INTERNAL FRAME ASS’Y 48” X 22” X 10” (INCLUDING ITEM 13)
14
1
-
1
-
1
*
*
V07855
INSTALLATION GUIDE
PARTS BAG (ELECTRICAL CABLE CLAMP LP16-AP (1),
1
V13278 WIRE CONNECTORS NO. 74B (2), DOUBLE THREADED SCREWS 6-12 X 0.5 (6),
SCREWS NO. 8 X 3/8’’ (6), NUTS NO. 10-32 (4), SCREWS NO. 6 X 1/2’’ (2))
1
1
1
1
*
NOT SHOWN.
- 16 -
Download from Www.Somanuals.com. All Manuals Search And Download.
|