Belkin Door W1896B 03 01 User Manual

AL-PCI  
PC to Digital Lock Interface  
INSTALLATION INSTRUCTIONS  
345 Bayview Avenue  
Amityville, New York 11701  
For Sales and Repairs 1-800-ALA-LOCK  
For Technical Service 1-800-645-9440  
© ALARM LOCK 2001  
WI896B 03/01  
GENERAL DESCRIPTION  
CONNECTION  
The AL-PCI is an interface cable which allows high  
speed communication between a PC running DL-  
Windows software and a compatible Trilogy Digital Lock,  
Data Transfer Module, or a AL-PRE prox card reader. Us-  
ing the AL-PCI, the PC can upload or download program-  
ming to/from the lock, and upload event history.  
Refer to the following wiring diagrams/ applica-  
tions.  
Compatible Trilogy Digital Locks:  
·
·
·
DL3000  
DL3500  
PDL3000  
Application 1 Program the Lock directly using a PC  
or Laptop  
SPECIFICATIONS  
Input Power: Supplied by the computer and lock con-  
nections  
Dimensions: 2 5/8” L X 1 1/4 ”H X 3/4” W  
SYSTEM REQUIREMENTS  
·
IBM PC or compatible desktop or notebook computer  
with 233 MHz or faster processor.  
·
·
·
·
·
At least 10 Mb available on hard drive  
At least 64 MB of RAM memory  
Microsoft Windows 95, 98, NT4.0 or higher  
DL-Windows  
Application 2 Send Trilogy Lock Programs from PC  
to AL-DTM for transfer to multiple Digital Locks OR use  
the AL-DTM to retrieve system activity reports from  
locks to be transferred to the PC.  
One unused RS-232 Serial Communications port  
(Com 1– 4), or USB Port (see NOTE 1).  
OPERATION  
For details regarding the use of the AL-PCI, refer to DL-  
Windows User Guide OI237.  
NOTE 1:  
The AL-PCI may be used on Notebook Computer  
models which have USB ports when used with the  
Belkin model F5U103 USB Serial Adapter. It has been  
tested and approved for use with DL-Windows and the  
AL-PCI.  
Application 3 Connect the AL-PRE Prox Card Enroller  
to the PC to read Prox Cards directly into DL-Windows.  
NOTE 2:  
For more information, or to order, go to the Belkin  
website at: www.belkin.com  
The AL-PCI is designed to be used on a 9 pin serial  
Com Port. If your computer has a 25 pin Com Port, a  
25 pin to 9 pin adapter must be used. Warning:  
Polarity MUST be observed when connecting to the  
lock. The tab (-) must plug into the left hole (black).  
Trilogy(R) is a registered trademark of Alarm Lock.  
Windows is a trademark of Microsoft  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Network Card F5D7050 User Manual
Black Decker Sander BDSA100 User Manual
Bock Water heaters Water Heater 241E User Manual
Briggs Stratton Portable Generator NEMA 3R User Manual
Bush Hog Brush Cutter GT42 User Manual
Bushnell Binoculars 263230CL User Manual
Canon Printer 12021 10 UD2 001 User Manual
Casio Digital Camera EX S20U EX M20U User Manual
Chauvet Washer 260 LED User Manual
Chicago Electric Cordless Saw 94488 User Manual