TRACER ETHERNET SWITCH MODULE
P/N 1280050L1
Quick Start Guide
INSTALLATION INSTRUCTIONS
The TRACER Ethernet Switch Module is not
hot-swappable. Remove power from the TRACER
system before installing or removing the module.
1. Remove the cover plate from the appropriate option slot in the TRACER
rear panel.
2. Slide the TRACER Ethernet Switch Module into the option slot until the
module is firmly positioned in the chassis.
3. Secure the thumbscrews at both edges of the module. Tighten with a
screwdriver.
4. Connect the cables to the associated device(s).
5. Complete installation of remaining modules and system as specified in
the TRACER 6000 Series System Manual.
SPECIFICATIONS
NETWORK CONNECTION PINOUT
Interface Type:
(4) 10BaseT/100BaseTX interfaces with auto MDI/MDIX
crossover on all interfaces
Pin
1
Name
RX1
Source
Description
Receive Positive
Receive Negative
Transmit Positive
—
Attached Equipment
Flow Control:
Back-pressure flow control on all half-duplex interfaces
Pause-frame flow control on full-duplex interfaces
2
RX2
Attached Equipment
3
TX1
Module
N/A
Environmental
Specifications:
Operating Temperature: -25°C to 65°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95% non-condensing
4, 5
6
UNUSED
TX2
Module
N/A
Transmit Negative
—
Compliance:
FCC Part 15, Class A
7, 8
UNUSED
Quick Start Guide, 61280050L1-13A, January 2005
Technical Support 1-888-4ADTRAN (1-888-423-8726)
Download from Www.Somanuals.com. All Manuals Search And Download.
Copyright © 2005 ADTRAN, All Rights Reserved
|