Installation Instructions
KM 400 Electric Cooktop
KM 402 / KM 403 Fryer
KM 408-1 Contact Grill
KM 410 / KM 411 Electric Barbecue
UV
To prevent accidents and
machine damage,
read these instructions
before installation or use.
M.-Nr. 05 060 863
Contents
Appliance dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cutting out the countertop. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Securing the support bars. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Locking the appliance into place . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3
IMPORTANT SAFETY INSTRUCTIONS
Note to the installer:
Please leave this instruction book
with the consumer for the local
electrical inspector’s use.
Installation
The minimum distances given in
these Installation Instructions must
be observed in order to ensure safe
operation. Failure to do so increases
recommended
the risk of fire.
To prevent appliance damage, the
cabinetry and venting hood should
be installed first.
The countertop must be bonded
with heat resistant (212 °F/100 °C)
adhesive to prevent distortion.
The cooktops should only be
installed in the illustrations, while
maintaining the required safety
distances shown. Do not install the
cooktop between two tall cabinets, this
is a fire hazard.
not recommended
a = Minimum safety distances:
KM 400 = 2" (50 mm)
KM 402 / 403= 2" (50 mm)
KM 408-1 = 2" (50 mm)
KM 410 / 411 =10" (250 mm)
Deep fryers must not be installed
next to gas cooktops. Gas flames
can ignite splattering oil. A distance of
at least 12" (305 mm) should be
maintained between these two
appliances.
not allowed
4
IMPORTANT SAFETY INSTRUCTIONS
Cooktops should not be installed
above a dishwasher, washer, dryer,
freezer or refrigerator. The high
temperatures radiated downwards from
the cooktops could damage these
appliances.
Safety distance above the appliances
This equipment has not been
designed for maritime use or for
use in mobile installations such as
aircraft or recreational vehicles.
However, under certain circumstances
it may be possible for an installation in
these applications. Please contact the
nearest Miele Dealer or the Miele
Technical Service Department with
specific requirements.
As a general rule there must be a
minimum safety distance of at least 30
inches (760 mm) between the top of the
appliance and any cabinet above it, b.
The minimum distance of combustible
surfaces located above and to the side
of the cooktop, c, is 18" (457 mm).
Make sure that the power cord to
the cooktop does not come into
contact with any mechanical parts once
the cooktop has been installed.
If the cabinet manufacturer
recommends a different distance, follow
that manufacturer’s recommendation.
The minimum safety distance
between the KM 410 / KM 411 and
the bottom of a venting hood should
be no less than 26" (650 mm).
If more than one appliance is
installed beneath a hood and they
have different minimum safety
distances, the greater distance
should be followed.
Keep this instruction book in a safe
place and pass it on to any future
owner.
5
Installation
Cutting out the countertop
Installing one or multiple appliances:
Cut out the countertop using the
dimensions listed in the following table.
Number of
cooktops
Cut out width
Dimension "B"
1
2
3
4
5
6
7
10 13/16" (274 mm)
22 1/8"
(562 mm)
(850 mm)
(1138 mm)
(1426 mm)
(1714 mm)
33 7/16"
44 13
/
16
56 1/8"
67 1/2"
All Miele combisets have the same
length and width. Make sure that there
is enough room beneath the countertop
to allow for the depth of the various
appliances. When installing a KM 402 /
KM 403 or KM 410 / KM 411 remember
to allow clearance for the drain valve
that will be located in the cabinet
beneath the appliances.
78 13/16" (2002 mm)
The tolerance for each dimension is
1/16" (1 mm).
When installing more than one
combiset cooktop, a support bar
must be installed between the
appliances. Install the support bars
as shown on the following page
before setting the appliances into
the countertop.
The following safety distances must be
maintained:
– Between the cooktop and rear wall:
2" (50 mm).
– Between the cooktop and side wall
or cabinet:
KM 400 = 2" (50 mm)
KM 402 / 403= 2" (50 mm)
KM 408-1 = 2" (50 mm)
KM 410 / 411 =10" (250 mm)
Refer to section "Important Safety
Instructions" for further information.
9
Installation
Laying out the support bars
and clamps
aClamps
cSlight gap between support bar and
countertop.
bSupport bars
This illustration shows the layout for 3
combisets, their respective support
bars, b, and the 14 spring clamps, a,
required for correct installation.
If more than 3 combisets are being
installed, add an additional 11 3/8"
(288 mm) to the overall width of the cut
out for each extra combiset, or use the
table on the preceding page.
10
Installation
Securing the support bars
Securing the spring clamps
d
c
Wood or Corian countertops
Wood or Corian countertops
^ Arrange the bars, b, as shown in the
^ Place the spring clamps, a, as
illustration
shown in the illustration.
^ Drill 1/16" (1.5 mm) pilot holes through
the brackets and secure them using
the supplied screws.
^ Drill two 1/16" (1.5 mm) pilot holes for
each clamp and secure using the
supplied screws.
^ Fill the gap, c, between the bars and
the countertop using the supplied
silicon sealant.
Granite countertops
Granite countertops
For granite countertops, the spring
clamps can be secured using
double-sided construction adhesive.
Do not allow the spring clamps to
"float", they must be securely fastened.
For granite countertops, the support
bars, b, can be secured using
double-sided construction tape. Do not
allow the bars to "float", they must be
securely fastened. Fill the gap, c,
between the bars and the countertop
using the supplied silicon sealant.
The screws are not necessary for
granite countertops.
The screws are not necessary for
granite countertops.
11
Installation
Locking the appliance into
place
Make sure the cooktops are aligned
correctly before setting them into the
countertop. Once the spring clamps
are engaged, a special tool is
required to release the cooktop from
the clamps.
^ Guide the power cord through the cut
out and connect the appliance to the
electrical supply.
^ Position the cooktop over the cut out.
With a hand on each side, above the
clamps, a, press the cooktop down,
locking it into the spring clamps.
Make sure that the cooktop rim lies
flat against the countertop on all
sides.
12
Installation
Important
The cooktop must not be
permanently sealed into the
countertop when installed.
The sealing strip under the edge of
the cooktop provides a sufficient
seal for the countertop.
If the cooktop is sealed into position,
the countertop or the appliance may be
damaged if the cooktop needs to be
removed for maintenance or service.
13
Electrical connection
Power supply:
,WARNING:
– 240 V, 60 Hz, 15 A fuse rating
or
Disconnect the appliance from the
main power supply before servicing.
To reduce the risk of electric shock,
make sure that the appliance is
properly grounded after installation.
– 208 V, 60 Hz, 15 A fuse rating
The oven is equipped with a power
cord consisting of 3 leads. They must
be connected to a dedicated line
through the use of an approved
junction box
To guarantee the electrical safety of
this appliance; continuity must exist
between the appliance and an
effective grounding system. It is
imperative that this basic safety
requirement be met. If there is any
doubt, have the electrical system of
the house checked by a qualified
electrician. The manufacturer cannot
be held responsible for damages
caused by the lack, or inadequacy
of an, effective grounding system.
Black : connect to L1 (hot)
Red: connect to L2 (hot)
Green: connect to GND (ground):
For further information, see the
wiring diagram provided with the
appliance.
All electrical work should be
performed by a qualified electrician
in accordance with local codes and
the:
WARNING:
THIS APPLIANCE MUST BE
GROUNDED
-
National Electrical code
ANSI / NFPA No. 70-1481
for USA
or
-
Canadian Electrical Code Part I
(CSA Standard C 22.1)
for Canada
Note to the installer:
Please leave these instructions with the
consumer.
14
15
Alterations rights reserved / 0705
M.-Nr. 05 060 863 / 01
en - US
|