5. When Windows starts, it will find a 2SP-PCI Controller and will ask  
you for a driver for this device.When prompted, insert the  
installation diskette into your floppy drive. After copying the  
necessary files from the diskette,Windows may restart your PC in  
order to complete the installation of the 2SP-PCI card. Any Plug and  
Play devices attached to the 2SP-PCI will now also be detected and  
installed.Windows XP may display a message to the effect that the  
drivers are not digitally signed.This warning can be ignored.  
6. To view how Windows has installed the 2SP-PCI, open Windows'  
Device Manager. Please note that the 2SP-PCI will appear in Device  
Manager under two separate entries.The two serial ports will appear  
both under the Multifunction Adapters tree and under the Ports  
tree, while the Parallel port will appear under Ports only (see  
example below). Please use the appropriate listings if you wish to  
customize any of the 2SP-PCI card’s settings. Please note that  
changes to default settings may be required by users connecting  
the 2SP-PCI card to a non-printer peripheral (see reverse). Users  
connecting a printer should use default settings.  
Connecting a non-printer device  
(e.g. external drive or parallel scanner)  
to the 2SP-PCI's parallel port  
In Windows 95/98/ME (not Windows 2000/XP) some parallel port  
devices require parallel ports that use standard (legacy) ISA LPT  
addresses (0278h or 0378h). Because the 2SP-PCI card is a fully  
compliant PCI device, its default address (Input/Output Range) is  
beyond the standard range of ISA I/O addresses. In order to connect  
such a peripheral to the 2SP-PCI card, the I/O address range of the card  
must therefore be changed manually.This section describes how this is  
done.  
1. Open Control Panel|System|Device Manager and find the Parallel-  
PCI listing under Ports. Click Properties, and proceed to the  
Resources tab.The following screen will appear (Note: the  
Input/Output Range and Interrupt of your particular configuration  
may differ from the one below).  
2. Remove the check mark from the Use Automatic Settings box.  
Note: In some cases Windows will give an error message to the effect  
that "Windows cannot modify this resource" at this point. If you are  
unable to access the settings for changing system resources, reboot the  
system in Safe Mode to make changes to resource settings. (To enter  
Safe Mode, press the F8 key while the system is rebooting.)  
3. Double-click on the words Input/Output Range.The following  
screen will appear:  
4. Use the up/down arrows to scroll to one of the following range  
settings, or type them in manually:  
0278 – 027F  
0238 – 023F  
0378 – 037F  
02B8 – 02BF  
0338 – 033F  
5. After one of these has been entered, click OK.Windows will verify  
whether you would like to force this particular configuration rather  
than the automatic one that it had previously chosen. Click Yes.  
6. Verify that there are no conflicts with addresses being used by other  
devices already in your PC. If no conflicts are found, restart Windows.  
Changing the Com numbering of your 2SP-PCI  
ports (Windows 95/98/Me only)  
Unless you already have more than 4 Com Ports installed in your PC,  
Windows will by default configure the serial ports of the 2SP-PCI as Com  
5 and Com 6. If you wish to change the assigned Com number of either  
of these ports (e.g. reassign Port 1 to be Com 3), please use the Lava  
Com Port Redirect Utility included in theUtils\Redirect“ subdirectory of  
your Installation Diskette. Such a reassignment may be necessary  
because some communications applications programs do not recognize  
port designations beyond Com 4.The Com Port Redirect utility will allow  
you to change the Com numbering of your ports without changing I/O  
address resources.  
To install the Port Redirect Utility on your hard drive, insert the  
Installation Diskette into your floppy drive, click Start, Run and type  
A:\Utils\Redirect\Setup.  
Changing the Com numbering of your 2SP-PCI  
ports (Windows 2000/XP only)  
In Windows 2000, Com port numbering can be changed by double-  
clicking the serial port entry displayed in Windows' Device Manager. Go  
to Port Settings | Advanced, and choose Com Port #.  
Using Zip Drives with the 2SP-PCI  
NOTE:The default input/output range for the 2SP-PCI card works with  
Zip™ drives using new Iomegaware™ software.The instructions  
"Connecting a non-printer device" given above apply to Zip™ drive  
users using old versions of Iomegaware™. For best results with Windows  
2000 and XP, we recommend downloading the latest "Iomegaware"  
from Iomega. Additional instructions on optimizing Zip Drive  
Release Notes:  
A. This documentation describes installing the 2SP-PCI on a  
Windows95/98/Me/2000/XP PC. Instructions and software for DOS,  
Windows 3.x, and Windows NT 4.0 may be found in the NT4.0  
subdirectory of the 2SP-PCI card Installation diskette. Instructions for  
B. Because the 2SP-PCI card uses PCI (not ISA) I/O address ranges, it will  
never be seen by your BIOS at boot-up as a standard port even if the  
address has been changed in Windows using the above procedure.  
This is normal, and does not indicate a fault in your 2SP-PCI card.  
C. The parallel port of the 2SP-PCI card will not work at address 0278h  
or 0378h if it is installed in a PCI slot that is behind a PCI-to-PCI  
bridge. If you have trouble installing the 2SP-PCI card, try seating it  
in a different slot.  
D. In standard installations of Windows 2000/XP, the I/O address cannot  
be changed to a legacy address.  
E. Some devices (like external CD writers) default to "word mode" (ie:  
16-bit data transfer) for fastest performance. Such devices need to  
operate in "byte mode" (8-bit data transfer) to work with the 2SP-  
PCI. Look in your device software for a "byte mode" setting, and  
enable it.  
Lava  
Technical Support  
9:00 am to 5:30 pm Monday to Friday (Eastern Time)  
Tel: +416 674-5942  
Fax: + 416 674-8262  
Lava Computer MFG Inc.  
This device complies with part 15 of the FCC Rules. Operation is subject  
to the following conditions: (1) This device may not cause harmful interference,  
and (2) this device must accept any interference received, including interference  
that may cause undesired operation.  
Lava Computer MFG Inc. 908 Niagara Falls Blvd. #629. North Tonawanda NY 14120-2060  

HP Hewlett Packard vp19 User Manual
Hyundai IT U90P User Manual
Insignia NS 14FTV User Manual
Intel 386 User Manual
JVC LT 26ED6SU User Manual
LG Electronics W2600H User Manual
Manhattan Computer Products QUICK START 176408 User Manual
NEC Electronics America Cordless Telephone 1093092 User Manual
Philips 107H67 User Manual
Philips MCD196 User Manual