MA0402-EB
Operation Guide DQR-100U
Main unit
Sub-unit
1
A
C
B
°C/ °F
RESET
SNZ
ON
OFF
SNZ
ON
OFF
5
ALM
ALM
TEMP.
MAX/MIN
CLEAR
°C/ °F
RESET
RESET
SET
)
UP(+)
–
(
N
W
O
D
TEMP.
MAX/MIN
CLEAR
9
8
7
4
3
0
6
RESET
SET
)
UP(+)
–
(
N
OW
D
2
• A sticker is affixed to the glass of this clock when you purchase it. Be sure to remove the sticker before using the
clock.
• Depending on the clock model, the configuration of your clock may differ somewhat from that shown in the
illustration.
2
Alarm Off
Current time
(Hour, minutes, seconds)
Alarm On
Snooze on indicator
Day of the week
Alarm on
indicator
PM indicator
Alarm time
DATE (month – date)
Wave OK indicator
Antenna Icon
1
Current Temperature
(INDOOR)
Current Temperature
(OUTDOOR)
• In locations subject to radio frequency interference, the product may malfunction and require you to reset the
product.
1
Operation Guide DQR-100U
2. While the screen you want is on the display, use the Alarm Time Set buttons (2) to change the digits that are
flashing.
USING THE CLOCK
Any of the following procedures can be used to set current date and time.
• Auto receive of the time calibration signal
TEMP
MAX/MIN
.
CLEAR
• Manual receive of the time calibration signal
• Manual setting without using the time calibration signal
Press + to increase
the flashing digits.
Press
—
to decrease
the flashing digits.
RESET
SET
)
–
UP
(+
)
DOWN(
Auto Receive
• The clock receives the time calibration signal eight times each day (1:00, 4:00, 7:00, 10:00, 13:00, 16:00, 19:00,
22:00).
• Holding down + or – changes the flashing digits at high speed.
• You can set the year in the range of 2000 to 2039. The day of the week is set automatically in accordance with
the date setting.
• A signal receive operation takes from two to ten minutes under good signal conditions.
• A receive indicator shows the current status of the receive operation.
• Pressing + or – while the Time Setting Screen is on the display causes the seconds count to be reset to 00.
• Each press of + or – while the 12-hour/24-hour Timekeeping Screen is on the display toggles between 12-hour
and 24-hour timekeeping.
Antenna Icon
Receive in progress: Icon flashes
Receive failed: Icon not displayed
Receive successful: Icon displayed
3. After making the settings you want, use the SET button (3) to display the Normal Timekeeping Screen.
• The clock automatically returns to the Normal Timekeeping Screen if you leave a setting screen on the display for
about three minutes without performing any operation.
Wave OK Indicator
Receive in Progress: OK not displayed
All receives over the past 24 hours failed: OK not displayed
At least one successful receive over the past 24 hours: OK displayed
USING THE ALARM
The alarm sounds and the light turns on when the alarm time you set is reached. You can also use the Alarm
Unsuccessful Signal Reception
Mode selector (5) to select the snooze alarm feature.
The antenna icon disappears from the display when a signal receive operation is unsuccessful. If this happens,
try changing the position or orientation of the clock, and press the WAVE button (4) to receive again.
Setting the Alarm Time
Use the Alarm Time Set buttons (2) to set the alarm time.
Pressing the Alarm Time Set buttons (2) causes the alarm time to appear in place of the date on the display.
Manual Receive
• Press the WAVE button (4) to start a calibration signal receive operation.
• Use the WAVE button (4) to perform a receive operation after replacing the clock’s batteries or if the auto
receive operation was not performed correctly for some reason.
• The clock beeps and display illumination flashes for about three seconds when a receive operation trigged by the
WAVE button (4) is successful.
TEMP
.
CLEAR
MAX/MIN
Press to change the
alarm time setting (+).
Press to change the
alarm time setting (
—
).
RESET
SET
)
–
U
P
(+
)
WN(
O
D
Important!
• Do not perform any button or switch operation while a signal receive operation is in progress.
• The time calibration signal includes both Standard Time and Daylight Saving Time (summer time) data.
• The DST indicator appears on the display when Daylight Saving Time (summer time) data is received.
• Holding down + or – changes the digits at high speed.
Turning the Alarm On and Off
Setting the Time and Date Manually
Use the Alarm Mode selector (5) on the side of the clock to turn the alarm on and off, and to select the snooze
• When using the clock in an area that is outside of the range of the transmitter in Rugby or in an area where signal
reception is impossible for some reason, you need to manually adjust the time as required.
1. Press the SET button (3) to cycle through the setting screens as shown below.
feature.
Alarm Mode selector
SNZ
Description
The alarm sounds at the preset time for one minute, and seven more
times every five minutes thereafter. Even if you stop the alarm sound
by pressing the SNOOZE/LIGHT button (1), the alarm operation is
performed again five minutes later.
Normal Timekeeping Screen
( )
• The indicator
snooze feature is activated.
flashes on the display to indicate that the
ALM ON
The alarm sounds at the preset time for one minute.
( )
ALM OFF
Year Setting Screen
12-hour/24-hour Timekeeping Screen
The alarm does not sound.
• The alarm time appears in place of the date on the display whenever the Alarm Mode selector (5) is set to ON
or SNZ.
• The light also turns on for the first four seconds that the alarm sounds.
• The alarm sound changes over four levels as it sounds.
Stopping the Alarm
• When alarm is sounding, press the SNOOZE/LIGHT button (1) to stop it. When the snooze feature is turned
Month and Day Setting Screen
Time Setting Screen
on, the alarm will sound again in about five minutes.
• To turn off the snooze feature, slide the Alarm Mode selector (5) to OFF.
3
Operation Guide DQR-100U
USING THE LIGHT
THERMOMETER FUNCTIONS
Pressing the SNOOZE/LIGHT button (1) turns on the light and illuminates the display for easy reading in the
Both the main unit and the sub-unit are equipped with their own temperature sensors. Temperature data measured
by the sub-unit is sent by wireless transfer to the main unit. This makes it possible to view both the indoor and
outdoor temperature on the main unit display.
dark.
Important!
• Overuse of the light can shorten battery life.
Temperature Measurements
• Both the main unit and the sub-unit take temperature measurements every 16 seconds.
• The temperature display shows “LO” for temperatures below –50°C (–58°F) and “HI” for temperatures above
70°C (158°F).
• Though temperature readings are displayed up to 0°C (32°F) and greater than 41°C (105°F), note that such
readings are actually outside the guaranteed temperature range of this clock.
BATTERY REPLACEMENT
Low Battery Warning
A
indicator appears on the display to let you know when battery power is low. Replace the batteries as soon
Switching between Celsius and Fahrenheit
• Push the °C/ °F button (9) to select either Celsius (°C) or Fahrenheit (°F).
as possible.
Note that the
indicator appears on both the main unit and sub-unit when sub-unit battery power goes low.
Celsius (°C)
Fahrenheit (°F)
To replace main unit batteries
Main unit
Replace batteries whenever the display of the clock becomes dim and difficult to read.
1. Open the battery compartment cover as shown in the illustration.
2. Remove all of the old batteries.
(INDOOR)
°C
°F
3. Load a full set of new batteries. Make sure that their positive (+) and negative (–) ends face in the correct
directions. If you load batteries incorrectly, they can burst and damage the clock.
4. Replace the battery compartment cover.
°C/ °F button (9)
Sub-unit
(OUTDOOR)
5. Press the RESET button (6). Be sure to press the RESET button (6) after replacing batteries.
°C
°F
To replace sub-unit batteries
1. Rotate the battery compartment cover from LOCK to OPEN.
2. Remove both old batteries.
3. Load new batteries. Make sure that their positive (+) and negative (–) ends face in the correct directions. If you
load batteries incorrectly, they can burst and damage the clock.
4. Replace the battery compartment cover.
5. Press the RESET button (B). Be sure to press the RESET button (B) after replacing batteries.
6. Press the RE-SYNC button (0).
High Temperature and Low Temperature Memory
• The following data is stored in memory automatically.
Main unit high temperature and low temperature
Sub-unit high temperature and low temperature
Battery precautions
• Keep batteries out of the reach of small children. If a battery is accidentally swallowed, contact your physician
immediately.
• Be sure to load the batteries with their positive (+) and negative (–) ends facing correctly.
• Never mix old and new batteries, or batteries of different brands.
• Never charge the batteries that come with the clock.
• Should batteries ever leak while in the clock, wipe out the fluid with a cloth, taking care not to let any get onto
your skin.
Current temperature
• Replace the batteries at least once a year, even if the current batteries are working properly.
• The batteries that come with the clock lose some of their power during transport and storage.
MAX/MIN TEMP. button (7)
Main unit high temperature and low temperature
Sub-unit high temperature and low temperature
4
Operation Guide DQR-100U
• To clear the high temperature and low temperature data memory, press the CLEAR button (8).
New data starts to be stored after memory is cleared.
MAIN UNIT/SUB UNIT COMMUNICATION PRECAUTIONS
Sub Unit Location
• Certain environmental conditions can greatly reduce the communication range.
• Avoid the following locations for the sub-unit.
CLEAR button (8)
Inside, among
buildings, or near
neon signs
Inside a vehicle
Near refrigerators
Near a
Near high-tension
power lines
or other household construction site,
appliances, near
office equipment,
mobile phones or
wireless LAN
airport, or other
sources of
electrical noise,
underground or in
tunnels, near
railroads,
devices.
highways, or radio
stations with
interfering
frequencies.
• Locating the sub-unit near a device that transmits radio signals using the same frequency as this product can
cause communication failure of this product.
• Avoid using multiple products in the same area. Doing so can cause mixing of their signals.
USING THE SUB-UNIT
Data Transfer from the Sub-unit
RADIO, EMC AND SAFETY REGULATIONS
This product complies with technical specifications required under EN 301 489-3,EN 300-220-3 and EN 60950.
• Data is transferred from the sub-unit to the main unit every three minutes.
• The sub-unit is able to send data to the main unit up to an unobstructed distance of about 30 meters.
• The data receive status is indicated on the display of the main unit by the icons shown below.
Receive successful
Receive unsuccessful
• If a receive operation is not successful for some reason, the display of the main unit shows dashes (–) in place of
the sub-unit temperature value.
• If you experience problems with data transfer, press the RE-SYNC button (0) to synchronize the two units. If
this does not eliminate the problem, try changing the positions or orientations of the main unit and sub-unit.
Switching between Celsius and Fahrenheit
• Push the °C/ °F button (A) to toggle between Celsius (°C) and Fahrenheit (°F).
Celsius (°C)
Fahrenheit (°F)
°C/ °F button (A)
Location
• Place the sub-unit in a location where it will not be exposed to rain, direct sunlight, or other elements.
5
|