Bunn Coffeemaker ES2SA User Manual

®
BUNNEspress  
ESPRESSO/CAPPUCCINO  
COFFEE BREWERS  
DISCONTINUED VERSION  
The information in this manual  
is no longer current.  
P-244/P-245  
TM  
E S2A / E S2SA  
TM  
ES 2 ES S  
OPERATING & SERVICE MANUAL  
BUNN-O-MATIC CORPORATION  
POST OFFICE BOX 3227  
SPRINGFIELD, ILLINOIS 62708-3227  
PHONE: (217) 529-6601 FAX: (217) 529-6644  
22700.0000A 11/93 ©1993 Bunn-O-Matic Corporation  
ES•2A/ES•2SA™  
INDEX  
BUNN Espress™  
Warranty..............................................................2  
User Notices........................................................3  
Features .......................................................... 4-5  
Installation  
Plumbing...............................................6  
Electrical Requirments and Hook-up ....7  
Initial Setup ...........................................8  
Programming ........................................9  
Brewing Procedures ...........................10  
Cleaning ............................................................11  
Trouble Shooting ......................................... 12-13  
Push-button Board Repacement.......................14  
Replacement Parts...................................... 16-31  
Wiring Diagrams.......................................... 32-33  
1
ES•2A/ES•2SA™  
WARRANTY  
BUNN Espress™  
Bunn-O-MaticCorp.(“Bunn”)warrantstheequipmentmanufacturedbyittobecommercially  
free from defects in material and workmanship existing at the time of manufacture and  
appearing within one year from the date of installation. This warranty does not apply to any  
equipment, componentorpartthatwasnotmanufacturedbyBunnorthat, inBunn’sjudgement,  
has been affected by misuse, neglect, alteration, improper installation or operation, improper  
maintenance or repair, damage or casualty.  
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER  
WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT  
LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS  
FOR A PARTICULAR PURPOSE. The agents, dealers or employees of Bunn are not  
authorized to make modifications to this warranty or to make additional warranties that are  
binding on Bunn. Accordingly, statements by such individuals, whether oral or written, do not  
constitute warranties and should not be relied upon.  
The Buyer shall give Bunn prompt notice of any claim to be made under this warranty by  
telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois, 62708-  
3227. If requested by Bunn, the Buyer shall ship the defective equipment prepaid to an  
authorized Bunn service location. If Bunn determines, in its sole discretion, that the equipment  
does not conform to the warranty, Bunn shall repair the equipment with no charge for parts  
during the one year warranty period and no charge for labor for the first 90 days of the warranty  
period. If Bunn determines that repair is not feasible, Bunn shall, at its sole option, replace the  
equipment or refund the purchase price for the equipment.  
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION  
ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WAR-  
RANTY OR OTHERWISE, SHALL BE LIMITED, AS SPECIFIED HEREIN, TO REPAIR OR,  
AT BUNN’S SOLE OPTION, REPLACEMENT OR REFUND. Bunn shall not be liable for any  
other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of  
equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute  
equipment, facilities or services, or any other special, incidental or consequential damages.  
2
ES•2A/ES•2SA™  
USER NOTICES  
BUNN Espress™  
The notices on this brewer should be kept in good condition. Replace unreadable or damaged labels.  
This equipment is to be installed to  
comply with the Basic Plumbing Code of  
the Building Officials and Code  
24247.0000  
Administrators International, Inc. (BOCA)  
and the Food Service Sanitation Manual  
of the Food and Drug Administration (FDA).  
00656.0000  
CAUTION  
HOT  
Liquid-Steam-Surfaces  
24246.0000  
!
WARNING  
Fill water tank before turning -on  
thermostat or connecting appliance  
to power source.  
Use only on a properly protected  
circuit capable of the rated load.  
Electrically ground the chassis.  
NOTICE  
This “Manual Fill Valve” is to be  
used during installation ONLY!  
Watch the sight gage during use  
and do not fill past normal line!  
Follow national/local electrical codes.  
Do not use near combustibles.  
24245.0000  
FAILURE TO COMPLY RISKS EQUIPMENT  
DAMAGE, FIRE, OR SHOCK HAZARD  
READ THE ENTIRE OPERATING MANUAL  
BEFORE BUYING OR USING THIS PRODUCT  
THIS APPLIANCE IS HEATED WHENEVER  
CONNECTED TO A POWER SOURCE  
00831.0000F 3/98 © 1988 BUNN-O-MATIC CORPORATION  
00831.0000  
3
ES•2A/ES•2SA™  
FEATURES  
BUNN Espress™  
HOT WATER RINSE DISPENSING TUBE AND STEAM DISPENSING TUBE  
The ES•2A™ ES•2SA™are equipped with a hot water rinse dispensing tube and two steam dispensing  
tubes. TheHotWaterrinsedispensingtubeiscontrolledbyaknobcentrallylocatedonthefrontofthebrewer.  
The Steam dispensing tubes are controlled by knobs located on the left and right side of the brewer, right knob  
controls the right side steam tube and the left knob controls the left side steam tube. They can be placed in  
a continuous flow position by turning the knobs approximately half way around. All three outlet tubes possess  
a rotary ball and socket type fitting for manual positioning.  
WATER FEED TAP  
This tap is of the automatically closing type. To introduce water into the tank, turn the control to the left  
or right, indistinctly and hold it in position. When you release the control, it will automatically close.  
LEVEL  
Water level should never rise above the maximum level zone (+) and never descend below the minimum  
level zone (-), as this may result in the heating element to melt. The optimum water level zone is indicated  
with (N). In the models with electronic water level control for the tank, The optimum water level (N) is  
maintained automatically.  
Tank  
The tank is made of copper plate, 1.5 mm thick and its components are made of cast or drop forged brass.  
The tank cover is fixed to the tank by bolts with exterior nuts to facilitate its removal. The operating pressure  
of the tank when in use should fluctuate between 0.9 and 1.2 bar as indicated on the tank pressure gauge with  
no air inside the tank. Whenever the machine is pressurized, the pressure indicated on the gauge should be  
checked to make sure it is the correct pressure. A pressure drop of 0.1 to 0.2 bar is considered normal. If  
there is an abnormal amount of air in the tank, a very quick pressure drop will be observed on the pressure  
gauge when one of the steam knobs are turned and steam is released. After a few moments, the real tank  
pressure can be read on the gauge.  
The difference of 0.9 to 1.2 bar, i.e. 0.3 bar, allows the effective exchange required to maintain the  
optimum temperature in the units.  
However, it is necessary that the installer, when installing the machine, decide at the installation site itself  
through the performance of the corresponding tests, the adequate thermal point or correct pressure, keeping  
in mind the working conditions of the machine, the hourly production rate required and the room temperature.  
PUMP SET  
The pump set is made up of a vane type, volumetric pump driven by a 0.25 HP single-phase motor,  
supplied at 220 v-60 Hz.  
If the water pressure exceeds 7-8 bar, a pressure reducer should be placed between the water line and  
the pump set to reduce the output pressure of the water line to between 3-4 bar, which will be the pump set  
water feed input pressure.  
The output pressure of the pump of the pump set should be between 8-9 bar as a maximum. To check  
this pressure, fill the cup of the coffee filter holder with pressed coffee and place it in any one of the infusion  
units, press the continuous flow button and read the pressure on the feed line pressure gauge. If the gauge  
does not show the previously mentioned values, the pump set’s delivery pressure should be adjusted. This  
is done by loosening the screw to reduce pressure. Adjust said screw until the desired pressure is obtained.  
The adjustment screw should only be turned very slowly.  
NOTE: Pump motor needs to be 1/4 -1/5hp, 1725 rpm, 230 volts, carbonator style, U.L. recognized  
4
ES•2A/ES•2SA™  
BUNN Espress™  
FEATURES  
IMPORTANT: None of the high pressure pumps found on the market can operate without water for a  
period of more than approximately ONE MINUTE, After one minute of dry operation the pump will seize and  
become unserviceable.  
Should water be shut off disconnect pump from power supply immediately.  
7
6
11  
10  
1
P-158  
Group head (Espresso extraction chamber)  
The group head-espresso extraction chamber is where the coffee infusion takes place. After extraction,  
an electric pressure valve automatically discharges the accumulated pressure. When the coil (12) of the  
electro-valve receives an electric current, causing the plunger (10) to move, thus closing the discharge valve  
(2) and opening the water intake valve (9) allowing the water to pass towards the shower (4) through the  
sprayer (3). This is when the brewing process (infusion) begins.  
The bubbling effect is produced by an interchange between air, contained in a bubble formed in the  
chamber, and water which progressively increases it’s pressure on that bubble. The mixture of air and water  
produced then falls on coffee previously dampened by the infusion process. When the liquid extraction  
process of the coffee is complete, excess pressure contained in the filter holder is then released through a  
discharge valve (2). The atomizer (1) directs the water being discharged to the opening to avoid it’s splashing  
outward.  
WATER TREATMENT  
It is essential to treat water entering the brewer to prevent lime scale build up in the boiler tank and other  
plumbing. Recommended treatments are reverse osmosis or softening. Polyphosphate type treatment for  
scale reduction, which works well on conventional coffee brewers, is not effective for espresso equipment.  
5
ES•2A/ES•2SA™  
PLUMBING  
BUNN Espress™  
PLUMBING REQUIREMENTS  
This brewer must be connected to a cold water system with an operating pressure between 20 and 90  
psi. A shut-off valve should be installed before the pump. Install a pressure regulator in the line when the  
pressure is greater than 90 psi. to reduce the pressure to 50 psi. The water inlet fitting is a 3/8 flare.  
ThisequipmentistobeinstalledtocomplywiththeBasicPlumbingcodeoftheBuildingOfficialsandCode  
Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug  
Administration (FDA).  
PLUMBING HOOK-UP  
1. Flush the water line and securely attach it to the 3/8” flare fitting on the inlet side of the pump.  
2. Connect one end of the braided hose (supplied) to the outlet side of the pump and the other end to  
the water inlet fitting located under the drain tray of the brewer. This tray is removable. Do not  
overtightenthefittings. Rubbergasketsareprovidedtobeinsertedintoeachendofthebraidedhose.  
3. Turn on the water supply and check for leaks.  
4. Plumbing diagram is shown below.  
PUMP  
Inlet  
Outlet  
Insert washer  
Insert washer  
3⁄8"  
copper  
P-138  
Braided hose  
Water supply line  
(from strainer)  
EasyClear filter  
brewer  
strainer  
supply  
line  
pump  
P-139  
Important: Both filter and strainer must be hooked up in system.  
6
ES•2A/ES•2SA™  
BUNN Espress™  
ELECTRICAL  
ELECTRICAL SPECIFICATIONS  
This brewer requires a 2-wire grounded service rated 208 to 240 volts ac, 20 amp, single phase, 60  
Hz.  
ELECTRICAL HOOKUP  
CAUTION: Improper installation will damage electronic components.  
1. An electrician must provide electrical service as specified.  
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.  
3. The plug for the brewer is to be supplied by the installer.  
4. Attach the plug to the brewer cordset as shown below:  
Red  
L1  
240V  
or  
208V  
Blk  
From  
brewe  
L2  
Grn  
Gnd  
P-140  
5. Attach wires from pump cordset to terminal block located on pump motor as shown below:  
Cover  
Grn/Yel  
Grommet Compression  
nut  
Brn  
Blu  
Blu  
Blk  
P-141  
Terminal  
block  
NOTE: Wiring going into the terminal block must be tinned with solder to insure proper connection.  
Warning: The brewer and pump must be electrically grounded. Do not assume that a plumbing line  
will provide an adequate ground.  
7
INITIAL SETUP  
ES•2A/ES•2SA™  
BUNN Espress™  
START-UP  
Retighten the tank cover bolts, nuts, flat section strips, tank heaters, and the individual tank section lids  
(at upper part of the tank). Fill the tank with water to the optimum water level zone (N) using the water feed  
tap. In the models with and electronic water level control fill the tank to the minimum water level zone (-).  
Connect the electrical system.  
Turn on the toggle switch located on the base (left side bottom). The indicator lamp on the front of the  
base (left side) will light up. When the toggle switch is turned on, in the model with an electronic water level  
control, the electronic water level operation pilot light will light up, start the pump set and open the water inlet  
valve(locatedinsidethemachine)introducingwaterintothetankuntilitreachestheoptimumwaterlevelzone  
(N).  
NOTE: During the initial fill of the tank, if manual fill is not used and automatic is filling the tank,  
the alarm condition will arise (during re-fill no water goes through the flowmeter). Refer to  
“DOSAGE PULSEMETER MALFUNCTION ALARM” in the TROUBLE SHOOTING section  
in this manual for further instruction.  
When the water makes contact with the sensor probe, this will close the inlet valve, shut off the pump set,  
and disconnect the pilot light.  
While waiting for the machine to reach working pressure (tank pressure gauge), check and adjust the  
pump set as on page 4.  
When the tank and the pump pipes are filled, press the “continuous doses” push button on each set and  
the pumping unit will immediately start injecting water into the corresponding tank section and tube leading  
to the units until water begins to flow through them. This indicates that air has been bled from the hydraulic  
circuit and the push-buttons can be pressed again to shut off the pump.  
Before the tank pressure reaches 1.2 bar, air must be bled from inside the tank as described on page 4.  
Whenthetankpressuregaugeindicates1.2bar,theelectricalpressureswitchwilldisconnect. Ifthisdoes  
not occur at the mentioned pressure, adjust the pressure switch (page 29 figure 1), placed inside the machine  
on the right side, using the inside adjustment screw. Tightening the screws lowers the tripping pressure and  
vice-versa.  
When the water in the individual tank sections and hydraulic circuit expands do to heating, the water  
pressure gauge reading will exceed 8-9 bar working pressure, and when the pressure reaches 11 bar the  
pressure release valve will open to release said pressure. If not, the inside nut (page 19 figure 13) must be  
adjusted so that it discharges the pressure at an indicated pressure of 11 bar.  
Place a dose of ground coffee (approx. 6 grams) in the cup of the filter-holder and after lightly tamping  
the coffee, and wiping the rim free of any excess grounds, place the filter holder in the group head unit.  
Turn on the push button control (red button) and all the mechanisms of the unit will begin operating, Let  
it run about 30 seconds and observe the pump feed pressure.  
8
ES•2A/ES•2SA™  
BUNN Espress™  
PROGRAMMING  
PUSH-BUTTON SET (AUTOMATICS ONLY)  
This set is made up of five push-buttons (A,B,C,D, and E) and one pilot light (F). The A, B, C, and D push-buttons  
are used to select the four possible water dosed and the E push-button is for continuous infusion injection.  
The F pilot light indicates that the unit is operating. To Shut off the infusion injection process (STOP), press  
any of the push-buttons (A, B, C, D, or E)  
F
D
E
A
B
C
PROGRAMMING DOSIFICATIONS  
To change the factory set dosages, set the Program/Run toggle switch to the “Program” (right) position.  
Depending on the dosage you wish to change (1 cup or 2 cups), fill the filter-holder with the proper amount  
of ground coffee and place in the hand infusion unit of the machine. Press the corresponding dosage push-  
button and hold for approximately 3 seconds. The brew light will be flashing. Once the desired amount of  
coffee is achieved press any of the dosage push-buttons to save the new setting in memory. Return the “Run/  
Program” switch lever to the “Run” (left) position.  
NOTES:1. This operation must be repeated for each dosage you wish to reprogram.  
2. The push-buttons which were not reprogrammed will continue using the previous dosage  
sets.  
3. The “Continuous dosage” is not programmable.  
PREINFUSION PROGRAMMING  
Pre-infusion causes a non-programmable amount of brew water to be injected into the bed of coffee at  
the beginning of the brew cycle; thus wetting the coffee, this is followed by a short delay, followed by the  
programmed amount of dispense.  
In order to check whether or not the pre-infusion has been turned on, turn the programming switch (14)  
to the “Program” (right) position. If the pilot lamp (F) comes on, pre-infusion is on. To eliminate the pre-  
infusion, press the continuous dosage button (E) until the pilot lamp (F) turns off; then return the programming  
switch to the “Run” position.  
9
BREWING  
ES•2A/ES•2SA™  
BUNN Espress™  
COFFEE EXTRACTION  
1. Place ground coffee in the filter holder, shake it level, and compress the bed of coffee with the tamper on  
the grinder.  
2. Clean the edge of the filter holder with the palm of the hand before locking it on to the set. This will prevent  
any coffee particles from imbedding themselves into the group gasket.  
3. Place the filter holder in the set and twist it to the right until tight. Do not force the filter holder excessively.  
4. Press any one of the four dosification buttons or the continuous draw button according to the dose  
required.  
5. Extraction ends automatically. If the continuous liquid dispensing button was pressed, dispensing can  
be stopped by pressing on any one of the five buttons. The automatic liquid extraction caused by using  
one of the four dosification buttons can be stopped by pressing any of the dosification buttons.  
NOTE: The automatic selections have regulated doses, these can be set between 0 and 500 cc  
The machines leave the factory with regulators adjusted for the following approximate amounts:  
One short coffee:  
One normal coffee:  
Two short coffees:  
Two normal coffees:  
50 cc of water  
100 cc of water  
100 cc of water  
200 cc of water  
It should be noted that these doses have been set without coffee in the filter holder. With coffee, the  
volumes are slightly less. Should different volumes be required, refer to (Programming dosifications)  
OBSERVATIONS  
IT IS OF THE UTMOST IMPORTANCE FOR THE INFUSER UNIT OPERATION that there is no  
intermediate space between the pressed coffee and the injector spray head. Coffee dosage is 6 grams,  
although it may be more or less depending on the degree of grinding, coffee quality, etc. Perfect grinding of  
the coffee gives it a better creme’. If it is observed that the coffee is produced drop by drop, it means that it  
is ground too fine, and if the coffee comes out too quickly, it means that the grounds have not been ground  
fine enough.  
During long periods in which the machine is not operating, drain the tank and clean the exterior of the  
machine, disconnect the power supply and cover the machine.  
For optimum operation and conservation, all the elements of the machine should periodically be  
lubricated.  
Beforemakingthefirstcupofcoffee,itisrecommendedtorunwaterthroughtheunittoheatupthesystem.  
10  
ES•2A/ES•2SA™  
CLEANING  
BUNN Espress™  
CLEANING  
1. The use of a damp cloth rinsed in any mild, nonabrasive, liquid detergent is recommended for cleaning  
all surfaces on Bunn-O-Matic equipment.  
2. A cleaning cycle must be ran nightly.  
To do this:  
a) insert solid filter basket into filter holder.  
b) Put 1 teaspoon of Cascade cleaning detergent into filter basket.  
c) insert filter holder into group head  
d) run brew cycle  
e) repeatedly start and stop brew cycles while observing drain cup under drip tray  
f) stop when water being discharged into drain cup shows no sign of detergent.  
3. Clean the gasket that seals the filter and the group head , located under the group head. Ground coffee  
build-up on the gasket will result in a bad seal of the filter holder, and will leak while brewing. This is why  
it is important to wipe excess coffee off of the rim of the filter prior to insertion in the group head.  
4. It is necessary once a week to remove the group head screen (under the head, fastened with a one slotted  
screw), and look through the screen to see if it needs to be cleaned.  
5. The drip tray is to be cleaned nightly. Remove the grill and drip pan, wash them out thoroughly, and place  
them back into the brewer.  
6. The steam wands must be cleaned after each use. Wipe with a damp cloth immediately after use. At the  
end of the night, run each wand for about 15 seconds to clean them out.  
11  
TROUBLESHOOTING  
ES•2A/ES•2SA™  
BUNN Espress™  
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems  
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic  
Technical Service Department at 1-800-637-8606.  
Inspection, testing, and repair of electrical equipment should be performed only by qualified service  
personnel.  
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are  
energized for more than ten minutes without a supply of water.  
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will  
help to avoid twists and kinks in the tubing.  
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.  
This brewer is heated at all times unless disconnected from the power source. Keep away from  
combustibles.  
WARNINGS  
Exercise extreme caution when servicing electrical equipment.  
Disconnect the brewer from the power source when servicing, except when specified.  
Follow recommended service procedures.  
Replace all protective shields and safety notices.  
Problem  
Equipment will not  
Probable cause  
No power or incorrect  
Remedy  
Connect the brewer to the power  
operate  
voltage  
source. Check the contactor  
terminals for proper voltages.  
Check circuit breaker/fuse.  
Contactor  
When on/off toggle (master) is  
turned on , pilot lamp on base  
should light up and the contactor  
should energize and pull in. If  
contactor does not pull in, unplug  
brewer and check coil for continuity.  
If open, replace contactor.  
Toggle switch (Master  
on/off)  
Must be in the on position. Pilot  
lamp will light.  
Brew cycle will not start  
No water  
Check plumbing and shut off valves.  
Water strainer or filter  
Direction of flow arrows must be  
pointing toward the brewer.  
Remove the strainer and/or filter  
cartridge and check for obstructions.  
Clear or replace.  
Start switch  
Disconnect power supply and check  
terminals of switch for continuity  
(semi-automatic version)  
Solenoid valve  
Check voltage at terminals. If  
voltage is present when the start  
switch is pressed, disconnect power  
supply and check coil terminal for  
continuity. If there is continuity,  
solenoid is defective. Replace  
solenoid.  
12  
ES•2A/ES•2SA™  
TROUBLESHOOTING  
BUNN Espress™  
Problem  
Probable cause  
Remedy  
Brew cycle will not  
start (cont.)  
Pump  
When starting switch is pressed, pump  
should turn on immediately. If this dies not  
happen, check voltage at terminal block on  
the pump.. If correct voltage is present, use  
a flat-blade screwdriver to turn the motor  
shaft on the rear end of the motor to see if  
the pump itself is locked up. If the shaft  
dies no turn, replace pump assembly.  
Remove the solenoid valve and clear it of  
any obstructions. Rebuild or replace the  
valve if necessary.  
Start switch  
Switch must make and break contacts.  
Check with ohmmeter for continuity.  
Water is not hot or  
long recovery time.  
Limit thermostat  
Check continuity of limit with ohmmeter.  
Disconnect power supply and check across  
limit terminals. If no continuity, replace  
limit thermostat.  
Tank heaters  
Check tank heater terminals for correct  
voltage. If voltage is present and machine  
is not heating properly, replace tank heater.  
A good tank heater will show continuity.  
DOSAGE PULSOMETER MALFUNCTION ALARM  
This alarm is activated if, for any reason, the pump is running and the metering pulses of the volumetric meter are not  
received by the central control unit, or when there is a time period longer than 5 seconds (approximately) between meter  
pulses. If an infusion unit is operating (pilot light on the push-button panel turned on), it will shut off and the pilot light will  
flash on and off. If this happens, the following should be checked:  
-Possible obstruction at the coffee outlet (dirty injection head, blocked unit nozzles, etc.)  
- Volumetric meter connections.  
- Unit electrovalve.  
- Unit electrovalve connections.  
- Operation of volumetric meter.  
- Possible pump malfunction.  
To cancel the alarm, just press any push-button on the infusion unit push-button panel that has produced the alarm,  
however, if the malfunction continues, the alarm will be reactivated when the programmed doses push-button is pressed.  
This alarm does not prevent the machine from operating in the continuous dosage mode.  
AUTOMATIC WATER LEVEL MALFUNCTION ALARM  
This alarm is activated when there is a demand for water but there is not enough water in the tank, and water level is  
not reached within a maximum prefixed time period in each tank, thus preventing a possible flooding of same. The pilot light  
on the push-button panel of the infusion units will flash on and off. If this happens, check the following:  
• Water level sensor.  
• Water inlet (possible blockage of inlet).  
• Water level sensor connection.  
• Tank water electrovalve.  
This alarm does not prevent the machine from operating in the continuous infusion mode and will not be shut off even  
though the machine is disconnected from the electric supply line. Should this occur, the optical level should be checked  
by sight and water fed into the boiler manually.  
To cancel the alarm after the problem has been solved, place the programming switch in the programming position,  
then simultaneously press the push-buttons for one short dose and 2 short coffee doses. Then after the alarm has been  
shut off, return the programming switch to the operating position.  
Keep in mind that this alarm will surely be activated when filling a completely empty tank or with a very low water level  
(after repairs or commissioning of a new machine). To prevent the alarm from being activated, load the water manually.  
13  
BOARD REPLACEMENT ES•2A/ES•2SA™  
BUNN Espress™  
PUSH-BUTTON BOARD CONNECTIONS  
All the set push-button boards are the same and are to be coded only according to the place they occupy  
withrespecttotheinfusionunits.Thenumberingorderoftheinfusionunits(lst,2nd,3rdand4th),alwayscounted  
facing the machine and from left to right.  
Printed circuit  
Wiring connector  
board  
P-137  
Terminals for locating the  
jumper on the push button  
board,dependingontheunit  
being connected  
(See diagram below)  
Location of the jumper when placing the push-button board on unit No. 1  
Location of the jumper when placing the push-button board on unit No. 2  
Location of the jumper when placing the push-button board on unit No. 3  
Location of the jumper when placing the push-button board on unit No. 4  
14  
ES•2A/ES•2SA™  
BUNN Espress™  
15  
ES•2A/ES•2SA™  
REPLACEMENT PARTS  
BUNN Espress™  
P-225  
16  
ES•2A/ES•2SA™  
BUNN Espress™  
REPLACEMENT PARTS  
Figure  
Description  
PartNumber  
1.................. Vented top panel (hood) ......................... 22795.0000  
2.................. Top cup warmer panel ............................ 22319.0001  
3.................. Divider panel.......................................... 22782.0000  
4.................. Hood corner piece (left & right) .............. 22789.0000  
5.................. Cagenut(10-32) ..................................... 22851.0000  
6.................. Side panel mounting channel.................. 22776.0000  
7.................. Galvanized back plate ............................ 22765.0000  
8.................. Backpanel(upper).................................. 22787.0000  
9.................. Backpanel(lower) .................................. 22788.0000  
10................ Sidepanelendcap ................................. 22786.0000  
11................ Sidepaneldecoratorpiece...................... 22792.0000  
12................ Sidepanel(right) ..................................... 22790.0000  
13................ Machineframechassis ............................ 22764.0000  
14................ Chrome front panel................................. 22879.0000  
15................ Inletassy.mountingbracket.................... 22841.0000  
16................ Dischargetube........................................ 22661.0000  
17................ Drain cup mounting nut.......................... 24046.0000  
18................ Drain cup ............................................... 22832.0000  
19................ Baseframe .............................................. 22780.0001  
20................ Lower hood panel................................... 22797.0000  
21................ Drip tray ................................................. 22848.0000  
22................ Drip tray grate......................................... 22693.0000  
23................ Rubberfoot............................................. 22615.0000  
24................ Footextension ........................................ 22843.0000  
25................ Footextensionnut .................................. 24049.0100  
26................ Sidepanel(left) ....................................... 22791.0000  
27................ Fronthoodpanel(semi-automatic).......... 22881.0000  
27................ Front hood panel (automatic) .................. 22796.0000  
28................ Rubbergrommet(faucettube)................. 22842.0000  
17  
ES•2A/ES•2SA™  
BUNN Espress™  
REPLACEMENT PARTS  
REPLACEMENT PARTS  
P-235  
18  
ES•2A/ES•2SA™  
BUNN Espress™  
REPLACEMENT PARTS  
Figure  
Description  
PartNumber  
1.................. Inlet water fitting ..................................... 22849.0000  
2.................. Brew water inlet tube.............................. 22614.0000  
3.................. Heatexchangerbulkhead ....................... 22835.0000  
4.................. Nut ......................................................... 24048.0100  
5.................. Split lock washer..................................... 24028.0100  
6.................. Heatexchangertube(brew) .................... 22613.0000  
7.................. Stud ........................................................ 22834.0000  
8.................. Tank-endbulkhead ................................. 22768.0000  
9.................. 4-way steam fitting.................................. 22828.0000  
10................ O-ringseal .............................................. 22868.0000  
11................ Pressurepop-offvalves ........................... 22575.0000  
12................ Water inlet tube ...................................... 22857.0000  
13................ Steam outlet fitting .................................. 22850.0000  
14................ 2-way steam fitting.................................. 22827.0000  
15................ CopperO-ringseal ................................. 22867.0000  
16................ Tank-end water & steam fittings .............. 22817.0000  
17................ Tank(boiler) ........................................... 22826.0000  
18................ Compressionnut ..................................... 22815.0000  
19................ Tank heater, 1300W, 220V (left) ............. 22607.0000  
20................ Tank heater, 1300W, 220V (right)........... 22608.0000  
21................ Tank-endbulkheadgasket ...................... 22602.0000  
22................ ”L“ bracket.............................................. 22859.0000  
23................ Flatwasher ............................................. 24028.0001  
24................ Exchangertubegasket............................. 22612.0000  
25................ Tankheatermountingstud...................... 22580.0000  
26................ Hex bolt (bulkhead mounting) ................ 24008.0000  
27................ Tankheatermountingstud...................... 22580.0000  
28................ Tankheatergasket .................................. 22579.0000  
29................ Tank heater terminal shorting bar............ 22818.0000  
30................ Tank heater terminal cover shield ........... 22639.0000  
19  
REPLACEMENT PARTS  
ES•2A/ES•2SA™  
BUNN Espress™  
1
2
16  
Sol
Par
3
4
13  
5
6
12  
11  
7
8
9
Gro
Part
10  
Figure  
Description  
PartNumber  
1.................. Solenoidmountingscrews ...................... 24005.0400  
2.................. Solenoidassembly .................................. 22712.0000  
3.................. Group head end plug.............................. 22806.0000  
4.................. Group head end plug gasket ................... 22808.0000  
5.................. Grouphead ............................................ 22809.0100  
6.................. Filterholdersealgasket........................... 22571.0000  
7.................. Sprayhead ............................................... 22804.0000  
8.................. Sprayheadmountingscrews.................... 24007.0300  
9.................. Sprayheadscreen .................................... 22708.0000  
10................ Sprayheadscreenmountingscrew .......... 24006.0000  
11................ Group head mounting stud nut ............... 24048.0100  
12................ Group head mounting stud washer ......... 24028.0100  
13................ Group head mounting stud ..................... 22609.0000  
14................ Group head cover shield......................... 22783.0000  
15................ Cover shield bolt..................................... 24007.0000  
16................ Group head to tank gasket ...................... 22657.0000  
P-234  
20  
ES•2A/ES•2SA™  
REPLACEMENT PARTS  
BUNN Espress™  
11  
16  
12 13 14 15  
10  
4
9
8
7
6
5
4
3
1
2
Figure  
Description  
PartNumber  
1.................... Tank drain screw.......................................... 24006.0400  
2.................... Tank drain screw gasket .............................. 22836.0000  
3.................... Lower sight gauge elbow ............................. 22644.0000  
4.................... Seal washer ................................................. 22616.0000  
5.................... Sight gauge glass gasket ............................. 22617.0000  
6.................... Sight gauge glass compression nut ............. 22618.0000  
7.................... Sight gauge housing .................................... 22620.0000  
8.................... Sight gauge glass ........................................ 22619.0000  
9.................... Upper sight gauge elbow ............................. 22643.0000  
10.................. Probe assy. hex fitting.................................. 22629.0000  
11.................. Terminal block (probe) ................................. 22814.0000  
12.................. Flat washer .................................................. 24031.0000  
13.................. Lock washer ................................................. 24030.0000  
14.................. Mounting nut ................................................ 24050.0300  
15.................. Seal washer ................................................. 22868.0000  
16.................. Extension fitting............................................ 22831.0000  
P-233  
21  
REPLACEMENT PARTS  
ES•2A/ES•2SA™  
BUNN Espress™  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
Completevalveassy.–  
Part # 22685.0000  
1
24/25  
23  
22  
21  
20  
19  
18  
17  
16  
30 31 32 33 34  
28  
29  
27  
26  
P-240  
22  
ES•2A/ES•2SA™  
REPLACEMENT PARTS  
BUNN Espress™  
Figure  
Description  
PartNumber  
1.................. Actuatorshaft-steamvalve .................... 22684.0000  
2.................. Steam valve collar nut............................. 22824.0000  
3.................. Insertwasher........................................... 22862.0000  
4.................. Bluerubbergasket-steamvalve ............. 22605.0000  
5.................. Springsupportwasher............................. 24028.0000  
6.................. Actuator shaft coupling screw ................. 22766.0000  
7.................. Rubberseat-plunger.............................. 22604.0000  
8.................. Actuator shaft coupling ........................... 22833.0000  
9.................. Actuator pivot nut ................................... 22864.0000  
10................ Actuator pivot nut set screw.................... 24005.0000  
11................ Steamvalvesealfitting............................ 22825.0000  
12................ Steamvalvesealfittingsetscrew ............ 22869.0000  
13................ Spring-steamvalve ................................ 22606.0000  
14................ Plungershaft ........................................... 22823.0000  
15................ Valve body - steam valve ........................ 22611.0000  
16................ Cam mounting screw .............................. 24006.0000  
17................ Actuator cam .......................................... 22682.0000  
18................ Shaft-steamvalveactuator .................... 22681.0000  
19................ Housing-actuatorshaft .......................... 22781.0000  
20................ Knob mounting bushing.......................... 22621.0000  
21................ Knob mounting bushing screw................ 24006.0401  
22................ Knob-steam/faucet ................................ 22694.0000  
23................ Knobretainerscrew ................................ 24003.0500  
24................ Decal - steam knob ................................. 22779.0000  
25................ Decal - hot water .................................... 22778.0000  
26................ Nozzle - steam wand .............................. 22581.0000  
27................ Leftsidesteamwand............................... 22655.0000  
27................ Rightsteamwand ................................... 22649.0000  
28................ “O-ring” - rubber .................................... 22616.0000  
29................ Nut ......................................................... 24052.0300  
30................ Brassbushing .......................................... 22654.0000  
31................ Coil spring .............................................. 22653.0000  
32................ Rubbervalve........................................... 22652.0000  
33................ Retainingnut .......................................... 24052.0301  
34................ Bulkhead mounting nut........................... 22829.0000  
23  
REPLACEMENT PARTS  
ES•2A/ES•2SA™  
BUNN Espress™  
8
2  
21  
P-239  
24  
ES•2A/ES•2SA™  
BUNN Espress™ REPLACEMENT PARTS  
Figure  
Description  
PartNumber  
1.................. Hex nut – plunger shaft ........................... 22863.0000  
2.................. Blackthrushwasher ................................ 22624.0000  
3.................. Faucetvalvedetentpins.......................... 22845.0000  
4.................. Faucetvalvedetent ................................. 22626.0000  
5.................. Coppersealwasher................................. 22839.0000  
6.................. Faucetspring .......................................... 22610.0000  
7.................. Cotter pin................................................ 22798.0000  
8.................. Rubberseat ............................................. 22604.0000  
9.................. Valve body ............................................. 22852.0000  
10................ Plungershaft ........................................... 22622.0000  
11................ O-ring – plunger shaft ............................. 22572.0000  
12................ Panel mount fitting.................................. 22625.0000  
13................ Brassbearingholder ............................... 22627.0000  
14................ Bearing ................................................... 22623.0000  
15................ Label – water inlet .................................. 22777.0000  
15................ Label – hot water .................................... 22778.0000  
16................ Knob – steam-hot water-water inlet......... 22694.0000  
17................ Knobsetscrew........................................ 24003.0500  
18................ Valve mounting nut ................................ 22865.0000  
19................ Hot water tube ........................................ 22697.0000  
20................ Hot water nozzle .................................... 22844.0000  
21................ Pressureventcapnut .............................. 22840.0000  
22................ Coppersealgasket .................................. 22839.0000  
23................ Tensionadjustingnut .............................. 22813.0000  
24................ Pressurespring ........................................ 22830.0000  
25................ Plunger ................................................... 22838.0000  
26................ Rubberseat ............................................. 22604.0000  
27................ Pressureventhousing ............................. 22837.0000  
28................ Sealwasher............................................. 22868.0000  
29................ Water manifold body .............................. 22670.0000  
30................ Coppersealgasket .................................. 22867.0000  
31................ Inlet water check valve ........................... 22628.0000  
32................ Inlet water fitting ..................................... 22850.0000  
25  
REPLACEMENT PARTS  
ES•2A/ES•2SA™  
BUNN Espress™  
11  
5
4
3
2
1
P-238  
26  
ES•2A/ES•2SA™  
REPLACEMENT PARTS  
BUNN Espress™  
Figure  
Description  
PartNumber  
1.................. Dispense nozzle - 2 cup ......................... 22802.0000  
2.................. Nozzlesealwasher ................................. 22803.0000  
3.................. Filter holder ............................................ 22801.0200  
4.................. Filter support wire................................... 22819.0000  
5.................. Filter - 2 cup ........................................... 22710.0000  
6.................. Handle.................................................... 22704.0000  
7.................. Flatwasher-handle................................ 24028.0000  
8.................. Lock washer - handle.............................. 24028.0100  
9.................. Screw - handle ........................................ 24008.0400  
.................... Complete filter holder assy. - 2 cup......... 22706.0000  
10................ Dispense nozzle - 1cup .......................... 22705.0000  
11................ Filter - 1 cup ........................................... 22709.0000  
.................... Complete filter holder assy. - 1 cup......... 22707.0000  
12................ Pessuretestcup(noholes) ...................... 22807.0000  
13................ Drainhose .............................................. 22603.0000  
14................ Water inlet hose (pump out to machine in) . 22855.0000  
15................ Water inlet hose (supply to pump in) .......... 22662.0000  
16................ Rubbersealwasher-hose ...................... 22638.0000  
17................ Nut - legs ................................................ 24049.0100  
27  
ES•2A/ES•2SA™  
BUNN Espress™  
REPLACEMENT PARTS  
2
1
3
4
5
11  
12  
13  
9
8
7
10  
6
14  
18  
17  
16  
34  
15  
33  
32  
31  
30  
35 36  
38  
19  
20  
21  
22  
23  
24  
39  
37  
25  
26  
29  
27  
28  
P-237  
28  
ES•2A/ES•2SA™  
BUNN Espress™  
REPLACEMENT PARTS  
Figure  
Description  
PartNumber  
1.................. Pressureswitch-heatercontrol .............. 22574.0000  
2.................. Pressuregaugemountingbracket ............ 22645.0000  
3.................. Front hood face plate - 2 group ............... 22796.0000  
4.................. Pumppressuregauge .............................. 22692.0000  
5.................. Pump indicator lamp .............................. 22846.0000  
6.................. Switchselectpanel ................................. 22695.0000  
7.................. Switchselectpanelstandoff .................... 22698.0000  
8.................. Indicator lamp - brew ............................. 22674.0000  
9.................. Circuitboardassy. .................................. 22699.0000  
10................ Steampressuregauge.............................. 22680.0000  
11................ Strainerhousing ...................................... 22769.0000  
12................ Filterscreen ............................................ 22667.0000  
13................ Rubbero-ring.......................................... 22822.0000  
14................ Strainerhousingendcap......................... 22770.0000  
15................ Flow meter complete .............................. 22775.0000  
16................ Flowmeterfittinggasketwashers ............ 22868.0000  
17................ Outlet fitting - flow meter........................ 22821.0000  
18................ Inlet fitting - flow meter........................... 22771.0000  
19................ Refill solenoid end fitting - outlet ............ 22762.0000  
20................ Refill solenoid - complete ....................... 22646.0000  
21................ Endfittingsealwasher ............................ 22872.0000  
22................ Refill solenoid end fitting - inlet .............. 22805.0000  
23................ Refill solenoid - complete ....................... 22763.0000  
24................ Protective caps - pump fittings ................ 22665.0000  
25................ Pump outlet fitting .................................. 22905.0000  
26................ Pump impeller unit ................................. 22713.0000  
27................ Motorassy. ............................................. 22903.0000  
28................ Rubber foot - pump base......................... 22576.0000  
29................ Pumpassy.-complete ............................ 22904.0000  
30................ Electronic module - 2 group automatic ... 22577.0000  
31................ Modulebracketsupportstandoffs ........... 22773.0000  
32................ Bracketsupportstandoffnut.................... 24046.0000  
33................ Module bracket support .......................... 22774.0000  
34................ Programming switch - toggle................... 22816.0000  
35................ Terminal block mounting bracket ........... 22784.0000  
36................ Terminal block........................................ 22578.0000  
37................ Pump inlet fitting .................................... 22387.0000  
38................ Coil, 220V - refill valve ........................... 22890.0000  
39................ Capacitor - motor.................................... 22902.0000  
29  
ES•2A/ES•2SA™  
BUNN Espress™ REPLACEMENT PARTS  
3
5
8
10  
11  
12  
Figure  
Description  
PartNumber  
1.................. Red push button on/off switch................. 22687.0000  
2.................. Brew indicator light ................................ 22689.0000  
3.................. Switch/lamp mounting bracket screw...... 24005.0200  
4.................. Switch/lamp mounting bracket................ 22880.0000  
5.................. Brew on/off switch .................................. 22688.0000  
6.................. Front hood panel (2 group) ..................... 22881.0000  
7.................. Bezel - group on/off/indicator ................. 22686.0000  
8.................. Control module....................................... 22882.0000  
9.................. Socket - control module.......................... 22883.0000  
10................ Module/relaysupportbracket ................. 22691.0000  
11................ Relay ...................................................... 22635.0000  
12................ Socket-relay .......................................... 22884.0000  
P-236  
30  
ES•2A/ES•2SA™  
BUNN Espress™  
REPLACEMENT PARTS  
Replacement Parts Not Illustrated  
Figure  
Description  
Part Number  
1 ..........Water strainer 38” x 38” mflrd............................................... 01245.0000  
2 ..........Cordset ............................................................................... 01699.0000  
3 ..........Limit thermostat .................................................................. 04680.0004  
4 ..........Contactor coil ..................................................................... 06335.0002  
5 ..........Indicator lamp (240 volt)..................................................... 12984.0003  
6 ..........Pressure switch (water inlet) .............................................. 21397.0000  
7 ..........Toggle switch (master on/off) ............................................. 22566.0000  
8 ..........Base plate........................................................................... 22315.0000  
9 ..........Mylar shield (switch & solenoid, semi-automatic) .............. 22316.0000  
10 ..........3⁄8” flare x 3⁄8” mpt fitting (pump inlet) ................................. 22387.0000  
11 ..........Mylar shield (valve & switches, automatic) ........................ 22464.0000  
12 ..........Limit thermostat bracket ..................................................... 22563.0000  
13 ..........Tube, steam valve steam valve (right) ............................... 22648.0000  
14 ..........Tube, tank to right steam valve .......................................... 22650.0000  
15 ..........Tube, steam valve steam valve (left) ................................. 22651.0500  
16 ..........Tube, inlet valve to refill solenoid ....................................... 22656.0000  
17 ..........Tube, water inlet valve to heat exchange........................... 22660.0000  
18 ..........Tube, water inlet press. relief-drain .................................... 22661.0000  
19 ..........Tube, refill solenoid to tank ................................................ 22663.0000  
20 ..........Tube, water inlet valve ....................................................... 22664.0000  
21 ..........Tube, sight gauge to tank................................................... 22666.0000  
22 ..........Tube assy, drain manifold .................................................. 22669.0000  
23 ..........Tube, flow meter to group assy (auto) ............................... 22671.0000  
24 ..........Tube, flow meter to flow meter (auto) ................................ 22672.0000  
25 ..........Tube, left group solenoid to drain manifold ........................ 22673.0000  
26 ..........Tube, screen filter to flow meter ......................................... 22678.0000  
27 ..........Tube, right group solenoid to drain manifold ...................... 22679.0000  
28 ..........Tube, tank to steam valv (left) ............................................ 22767.0000  
29 ..........Tube, copper-chrome plated .............................................. 22772.0000  
30 ..........Tube, pump gage to flow meter.......................................... 22785.0000  
31 ..........Tube, tank to hot water valve ............................................. 22793.0000  
32 ..........Tube, tank to pressure gage .............................................. 22794.0000  
33 ..........Tube, tank to manual fill ..................................................... 22853.0000  
34 ..........Tube, tank to pessure switch.............................................. 22854.0000  
35 ..........Tube, tank to sight gage..................................................... 22856.0000  
36 ..........Ribbon cable ...................................................................... 22874.0000  
31  
ES•2A/ES•2SA™  
BUNN Espress™  
SCHEMATIC  
ES2SA  
P-243  
32  
ES•2A/ES•2SA™  
BUNN Espress™  
SCHEMATIC  
ES2A  
P-244  
33  

Nokia 5030 User Manual
Motorola StarTAc 7760 User Manual
Maxtor One Touch STM305004OTA3E5 RK User Manual
Magnavox AZ7000 User Manual
LaCie 2big Quadra User Manual
Koolatron Coffeemaker 12 Volt DC 10 Cup Coffee Maker User Manual
Kenwood KDC MP5029 User Manual
JVC KD LH911 User Manual
Fostex CR300 User Manual
FieldServer Dart FS 8700 78 User Manual