INTRODUCTION  
This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily  
configured for 120V 15 amp, 120/208V 20 amp or 120/240V 20 amp.The brewer may have a hot water  
faucet for allied beverage use. It is only for indoor use on a sturdy counter or shelf.  
CONTENTS  
Warranty............................................................................................... 2  
Contents .............................................................................................. 3  
Programming....................................................................................... 4  
Schematic Wiring Diagram............................................................... 10  
39132.3 040312  
Page 3  
PROGRAMMING  
PROGRAMMING THE BREWER  
The information in this manual covers only the differences between this model and the standard Axiom.  
Access to service level 4 is same as standard Axiom.  
The following function screens are in order of appearance. Each screen will have instructions on how to access,  
and the procedures to program the various functions of the brewer.  
IMPORTANT PROGRAMMING NOTES  
- READ CAREFULLY -  
To exit the programming mode at any time, press and release "ENABLE BREW ON/OFF" switch located on the  
front switch panel. The display will return to the MAIN SCREEN.  
If none of the programming switches are pressed within one minute during the setup of the brewer, the  
programming of the function screen that is being set will be exited and the display will return to the MAIN  
SCREEN.  
Always remember to place an empty server and funnel under the sprayhead when operating the brewer dur-  
ing the set-up of PULSE BREW, CALIBRATE FLOW and testing the brew valve in TEST OUTPUTS.  
PROGRAMMING LOCKOUT SWITCH  
(Mounted on main control board)  
This switch can be set to prevent access to the programming settings of the brewer. Once all the cor-  
rect brew settings are programmed, the operator can set the switch to the "LOCK" position to prohibit  
anyone from changing the settings.With the switch in the "LOCK" position, the programming menus  
can still be accessed to view the current settings. However, no changes will be saved.  
LOCK  
SET  
Disconnect brewer  
from power source  
before removing any  
panel!  
REVERSE  
FORWARD  
READY TO BREW  
WATER TEMP: 200°  
Push and hold left "hidden"  
button to access service  
program modes.  
39132.3 040312  
Page 4  
SERVICE PROGRAMMING  
Freq&AdjustCaps?  
NO YES  
DISPLAY BREW TIMES  
TEST RFID BOARD  
NO YES  
NO  
YES  
GLASS FRESH HRS  
(-) .5 (+)  
ThermalFresh HRS  
FRESHNESS TIMEOUT  
NO YES  
(-)  
2.0  
(+)  
WARMER MINs PAST  
FRESHNESS:  
FRESHNESS SCAN  
EXPIRATION ALARM  
5
NO  
DONE  
YES  
DISABLE  
ENABLE  
EXPIRATION SECS  
ADJUST ALARM  
SET DATE/TIME ?  
NO YES  
(-)  
10  
(+)  
NO VOLUME ? YES  
Return To Main Screen  
PRE-EXPIRE ALARM  
AXIOM  
DISABLE  
ENABLE  
VERSION xx.xx  
Displays Model &  
Software Version  
39132.3 040312  
Page 5  
SERVICE PROGRAMMING  
This allows you to monitor the frequency of the warmer(s) sensing  
coils.  
Freq&AdjustCaps?  
NO  
YES  
Also allows you to monitor the adjustment capacitors, which are used  
to keep the coil frequency at it's nominal value (125.0 khz)  
125.0 0000  
125.0 0000  
* TOP F  
* TOP R  
Use the "Brewer" button to toggle between screens.  
125.0 0000  
* MAIN  
Press right hidden button to advance to next function.  
This allows you to read the "age" of any brewed batch in a particular  
carafe (as long as it is equipped with an RFID chip). The sensor coil  
will read the chip and brewer will display time of day it was brewed.  
DISPLAY BREW TIMES  
NO  
YES  
This screen will automatically scroll through all warmers.  
Press right hidden button to advance to next function.  
MAY 10  
2010  
MAIN 10:00:00 AM  
This allows you to monitor individual sensing coils and RFID board.  
TEST RFID BOARD  
NO  
YES  
RFID CIRCUIT BOARD  
VERSION # xx.xx  
CONTINUED  
39132.3 040312  
Page 6  
SERVICE PROGRAMMING  
PRESS ANY SWITCH  
TO EXIT  
If a carafe is placed on a particular warmer, a "box" will appear next  
to it's indicator. If the box is filled (solid) it's not expired yet. If the  
box is empty, the time is expired. See example: MAIN = expired; Top  
Front = not expired; Top Rear = expired.  
10:00:00 AM  
M
TF  
TR  
Press right hidden button to advance to next function.  
Enables the "FRESHNESS ALERT!" message and sets the  
expiration time. The expiration time is the amount of time the  
product is allowed to sit in the glass decanter before an alert  
message is displayed. DEFAULT: .5  
GLASS FRESH HRS  
(-) .5 (+)  
Range: OFF/0.5 - 4.0 hrs  
Enables the "FRESHNESS ALERT!" message and sets the  
expiration time. The expiration time is the amount of time the  
product is allowed to sit in the thermal server before an alert  
message is displayed. DEFAULT: 2.0  
ThermalFresh HRS  
(-)  
2.0  
(+)  
Range: OFF/0.5 - 4.0 hrs  
Sets the amount of time the warmers will turn off after an alert  
message is displayed. DEFAULT: 5  
Range: OFF/1 - 30 min  
WARMER MINs PAST  
FRESHNESS:  
5
Allows brewer to continually scan the warmer sensor coils and  
display freshness times.  
FRESHNESS SCAN  
NO  
DONE  
YES  
Enable/Disable beeper.  
EXPIRATION ALARM  
DISABLE  
ENABLE  
CONTINUED  
39132.3 040312  
Page 7  
SERVICE PROGRAMMING  
Sets the amount of delay between alarm beeps.  
EXPIRATION SECS  
(-) 10 (+)  
Select "YES" to adjust beeper volume.  
ADJUST ALARM  
NO VOLUME ? YES  
Press "+" to increase volume, or "-" to decrease.  
ADJUST ALARM 5  
-
+
Select "YES" to set date and/or time.  
SET DATE/TIME ?  
NO YES  
Press "+" to scroll year forward, or "-" to scroll year back.  
Press "+" to scroll month forward, or "-" to scroll month back.  
YEAR 2010  
DONE  
(-)  
(-)  
(-)  
(+)  
(+)  
(+)  
MONTH MAY  
DONE  
Press "+" to scroll day forward, or "-" to scroll day back.  
DAY  
DONE  
10  
CONTINUED  
39132.3 040312  
Page 8  
SERVICE PROGRAMMING  
Press "+" to scroll hour forward, or "-" to scroll hour back.  
HOUR 10 AM  
DONE  
(-)  
(-)  
(-)  
(+)  
(+)  
(+)  
Press "+" to scroll minute forward, or "-" to scroll minute  
back.  
MINUTE 00  
DONE  
Press "+" to scroll seconds forward, or "-" to scroll seconds  
back.  
SECOND 00  
DONE  
Enable/disable the 5 minute warning beep for a carafe about  
to expire.  
PRE-EXPIRE ALARM  
DISABLE ENABLE  
EXIT  
39132.3 040312  
Page 9  
L1  
N
L2  
SCHEMATIC WIRING DIAGRAM  
AXIOM BrewWISE-DV  
Earth Ground  
GRN  
MAIN ON/OFF SWITCH  
(Late Models only)  
Chassis Ground  
BLK-14  
SELECTOR  
SWITCH  
LIMIT  
THERMOSTAT  
WHI-14  
WHI/VIO-14  
TANK HEATER  
1425W  
BLU-14  
BLK-14  
BLU-14  
BLK-14  
TANK HEATER  
RED-14  
OPTIONAL FAUCET HEATER  
2268W  
WHI  
WHI  
BREW STATION WARMER  
(CONTROLLED BY ENABLE BREW SW)  
REFILL  
BLK  
WHI/RED  
WHI  
WHI  
WHI/BLU  
SOL  
DISPENSE  
SOL  
BLU-14  
BLK-14  
WHI  
WHI  
WHI/GRN  
RELAY  
J1-1  
C
O
N
T
WHI  
BLK  
(TOP WARMERS)  
R
O
L
P2  
FRONT WARMER  
P1  
BRN/BLK  
BRN/BLK  
WHI  
BRN/BLK  
WHI/BLU  
WHI/RED  
YEL  
WHI/VIO  
VIO  
WHI  
J1-5  
P
C
B
O
A
R
D
W
H
I
P1, P2, &  
P3 ARE  
PINS OF A  
POLARIZED  
THREE-PIN  
CONNECTOR.  
P3  
P2  
REAR WARMER  
VIO  
WHI/GRN  
J1-10  
J13-1  
(LEFT WARMER)  
FRONT WARMER  
P1  
YEL  
WHI  
WHI  
J5-1  
J6-1  
J7-1  
BRN  
RED  
ORN  
YEL  
GRN  
BLU  
J1-1  
J1-5  
TOP REAR WARMER SENSOR  
LOWER WARMER SENSOR  
W
H
I
REAR WARMER  
P3  
WHI/VIO  
J13-5  
TOP FRONT WARMER SENSOR  
RFID  
BOARD  
RED  
BLK  
J12-1  
BEEPER  
CONTROL SWITCH ASSY CODES  
2 WARMERS 2 WARMERS 2 WARMERS  
CONTROL SWITCH ASSY  
(NOTE – ALL WARMERS ARE NOT  
AVAILABLE ON ALL MODELS!)  
ON LEFT  
A3  
ON TOP  
A3  
ON RIGHT  
A3  
STATIC  
SHIELD  
BREW STATION  
LEFT FRONT  
LEFT REAR  
J2-1  
J2-5  
A2  
A1  
TOP FRONT  
TOP REAR  
A5  
A6  
RIGHT FRONT  
RIGHT REAR  
START BREW  
LEFT HIDDEN  
RIGHT HIDDEN  
“DIGITAL”  
A5  
A6  
A4  
B1  
B2  
D1  
D2  
D3  
A4  
B1  
B2  
D1  
D2  
D3  
A4  
B1  
B2  
D1  
D2  
D3  
B1 A6 D1  
A3 D2  
A4 D3 A5 B2 A2  
A1  
J2-10  
“BREWER”  
“CONTROL”  
BRN  
GRN  
BLU  
J3-1  
J3-3  
WHI  
BLK  
J9-1  
LEVEL PROBE  
(SHORT)  
LEVEL PROBE  
(LONG)  
t°  
120V AC 2 WIRE  
120/208V AC 3 WIRE  
120/240V AC 3 WIRE  
SINGLE PHASE  
29077.0021A 06/10 ©2010 BUNN-O-MATIC CORPORATION  
39132.3 040312  
Page 10  

Microsoft Windows 8 Pro 64 Bit FQC05976 User Manual
Maxtor 5T040H4 User Manual
JVC KS FX480J User Manual
HoMedics SoundSpa SS 7000 User Manual
EVGA UV Plus+ UV 16 User Manual
DoubleSight Displays Computer Accessories DS 219STA User Manual
DeLonghi Coffeemaker EC330 User Manual
Dell POWEREDGE RADI H700 User Manual
Black & Decker DE755 User Manual
Alpine CDE 9842 User Manual