Weil McLain Gold Series 2 User Manual

Gas-fired  
Water boiler  
Series 2  
User’s  
Information  
NOTICE:  
Series1/Series2identification  
Read the boiler rating plate to  
determine the series number. The  
rating plate is located on the right  
side of the boiler.  
Manual  
Ultra-80, -105, -155, -230 & -310  
with  
If the information in this manual is not followed exactly, a fire or  
explosion may result, causing property damage, personal injury or  
loss of life.  
Do not store or use gasoline or other flammable vapors and liquids in the  
vicinity of this or any other appliance.  
WHAT TO DO IF YOU SMELL GAS  
Do not try to light any appliance.  
Do not touch any electrical switch; do not use any phone in your  
building.  
Immediately call your gas supplier from a neighbor’s phone. Follow  
the gas supplier’s instructions.  
If you cannot reach your gas supplier, call the fire department.  
Installation and service must be performed by a qualified installer, service  
technician or the gas supplier.  
Part No.550-100-027/0404  
GAS-FIRED WATER BOILER SERIES 2 — User’s Information Manual  
STOP!! — Read before proceeding  
Failure to adhere to the guidelines on this page can result in severe  
personal injury, death or substantial property damage.  
Boiler service and maintenance —  
To avoid electric shock, disconnect electrical supply before  
performing maintenance.  
To avoid severe burns, allow boiler to cool before performing  
maintenance.  
You must maintain the boiler as outlined in this manual and have the  
boiler started up and serviced at least annually by a qualified  
service technician to ensure boiler/system reliability.  
Boiler operation —  
Do not block flow of combustion or ventilation air to boiler. This  
boiler is equipped with a control which will automatically shut down  
the boiler should air or vent be blocked. If vent or air blockage is  
easily accessible and removable, remove it. The boiler should attempt  
to restart. If blockage is not obvious or cannot be removed, have the  
boiler and system checked by a qualified service technician.  
Do not allow contaminated air to enter the boiler air inlet pipe. See  
page 4 for details.  
Should overheating occur or gas supply fail to shut off, do not  
turn off or disconnect electrical supply to boiler. Instead, shut off the  
gas supply at a location external to the appliance.  
Do not use this boiler if any part has been under water.  
Immediately call a qualified service technician to inspect the boiler  
and to replace any part of the control system and any gas control, which  
has been under water.  
Boiler water —  
Have boiler water chemistry checked at least annually by a qualified  
service technician.  
DO NOT use petroleum-based cleaning or sealing compounds in  
boiler system. Gaskets and seals in the system may be damaged. This  
can result in substantial property damage.  
DO NOT use "homemade cures" or "boiler patent medicines".  
Serious damage to boiler, personnel and/or property may result.  
Continual fresh makeup water will reduce boiler life. Mineral build-  
up in boiler heat exchanger reduces heat transfer, overheats the metal,  
and causes heat exchanger failure. Addition of oxygen can cause internal  
corrosion in system components. Leaks in boiler or piping must be  
repaired at once to prevent makeup water.  
Do not add cold water to hot boiler. Thermal shock can cause boiler  
heat exchanger to crack.  
3
Part number 550-100-027/0404  
GAS-FIRED WATER BOILER SERIES 2 — User’s Information Manual  
Prevent combustion air contamination  
If the boiler combustion air inlet is located in any area Pool and laundry products and common household  
likely to cause contamination, or if products which and hobby products often contain fluorine or chlorine  
would contaminate the air cannot be removed, you compounds. When these chemicals pass through the  
must have the combustion air and vent repiped boiler, they can form strong acids. The acid can eat  
and terminated to another location. Contaminated through the boiler wall, causing serious damage and  
combustion air will damage the boiler, resulting in presenting a possible threat of flue gas spillage or boiler  
possible severe personal injury, death or substantial water leakage into the building.  
property damage.  
Please read the information listed below. If  
contaminating chemicals will be present near the  
location of the boiler combustion air inlet, have your  
installer pipe the boiler combustion air and vent to  
another location, per the Boiler manual.  
Do not operate an Ultra boiler if its combustion  
air inlet is located in a laundry room or pool facility,  
for example. These areas will always contain hazardous  
contaminants.  
4
Part number 550-100-027/0404  
GAS-FIRED WATER BOILER SERIES 2 — User’s Information Manual  
Perform maintenance per schedule below  
Follow the maintenance procedures given throughout this manual. Failure to perform the service and maintenance or  
follow the directions in this manual could result in damage to the boiler or system, resulting in severe personal injury,  
death or substantial property damage.  
5
Part number 550-100-027/0404  
GAS-FIRED WATER BOILER SERIES 2 — User’s Information Manual  
Maintenanceprocedures  
The boiler must be inspected and started annually, at the beginning of the heating  
season, by a qualified service technician. In addition, the maintenance and care  
of the boiler designated on page 5 and explained on pages 6 through 9 must be  
performed to assure maximum boiler efficiency and reliability. Failure to service  
and maintain the boiler and system could result in equipment failure, causing  
possible severe personal injury, death or substantial property damage.  
Boiler must be  
serviced and  
maintained  
The following information provides detailed instructions for completing the  
maintenance items listed in the maintenance schedule, page 5. In addition to  
this maintenance, the boiler must be serviced and started up at the beginning of  
each heating season by a qualified service technician.  
Daily  
To prevent potential of severe personal injury, death or substantial property  
damage, eliminate all materials discussed below from the boiler vicinity and the  
vicinity of boiler combustion air inlet. If contaminants are found:  
Check boiler area  
Remove products immediately from the area. If they have been there for an  
extended period, call a qualified service technician to inspect the boiler for  
possible damage from acid corrosion.  
If products cannot be removed, immediately call a qualified service technician  
to repipe vent and air piping and locate vent termination/air intake away from  
contaminated areas.  
1. Combustible/flammable materials — Do not store combustible materials, gasoline or  
any other flammable vapors or liquids near the boiler. Remove immediately if found.  
2. Air contaminants — Products containing chlorine or fluorine, if allowed to contaminate  
the boiler intake air, will cause acidic condensate in the boiler. This will cause significant  
damage to the boiler if allowed to continue. Read the list of potential materials listed on  
page 4 of this manual. If any of these products are in the room from which the boiler  
takes its combustion air, they must be removed immediately or the boiler combustion air  
(and vent termination) must be relocated to another area. See WARNING above.  
1. Verify that combustion and ventilation air openings to the boiler room and/or building  
Check air openings  
are open and unobstructed.  
2. Verify that boiler vent discharge and air intake are clean and free of obstructions. Remove  
any debris on the air intake or flue exhaust openings. If removing the debris does not  
allow the boiler to operate correctly afterwards, contact your qualifed service technician  
to inspect the boiler and vent/air systems.  
1. Make sure the pressure reading on the boiler pressure/temperature gauge does not exceed  
Check pressure/  
temperature gauge  
24 psig. Higher pressure may indicate a problem with the expansion tank.  
2. Contact a qualified service technician if problem persists.  
1. Visually inspect boiler front door to be sure it is sealed all around its perimeter. Verify that  
Verify boiler front  
the two lower thumb screws are tight.  
door is securely in  
Replace boiler jacket front door after servicing. The boiler front door must be  
securely fastened to the boiler to prevent boiler from drawing air from inside  
place  
the boiler room. This is particularly important if the boiler is located in the  
same room as other appliances. Failure to keep the door securely fastened could  
result in severe personal injury or death.  
6
Part number 550-100-027/0404  
GAS-FIRED WATER BOILER SERIES 2 — User’s Information Manual  
Maintenance procedures (continued)  
Monthly  
1. Visually inspect the flue gas vent piping for any signs of blockage, leakage or deterioration  
Check vent piping  
of the piping. Notify your qualified service technician at once if you find any problem.  
Failure to inspect the vent system as noted above and have it repaired by a  
qualifed service technician can result in vent system failure, causing severe  
personal injury or death.  
1. Visually inspect the air inlet elbow to be sure it is unobstructed. Inspect entire length of  
Check air piping  
air piping to ensure piping is intact and all joints are properly sealed.  
2. Call your qualified service technician if you notice any problems.  
1. Inspect the boiler relief valve and the relief valve discharge pipe for signs of weeping or  
Check relief valve  
leakage.  
2. If the relief valve often weeps, the expansion tank may not be working properly.  
Immediately contact your qualified service technician to inspect the boiler and system.  
1. While the boiler is running, check the discharge end of the condensate drain tubing and  
Check condensate  
drain system  
the open top of the condensate tee at the boiler (see lower right illustration, page 11, for  
location of tee). Make sure no flue gas is escaping from the condensate drain tubing or tee  
by holding your fingers in front of the opening.  
2. If you notice flue gas escaping, this indicates a dry condensate drain trap. See step 4 for  
procedure to fill trap. Call your qualified service technician to inspect the boiler and  
condensate line and refill the condensate trap if problem persists regularly.  
Under some circumstances an Ultra vent system may not produce enough  
condensate to keep the condensate trap full of liquid. If the trap is not full, small  
amounts of flue products can be emitted into the boiler room through the  
condensate drain line or tee. Follow procedure below to fill trap.  
3. Verify that the condensate drain line is unobstructed by slowly pouring water into the top  
of the PVC tee on the side of the boiler. The water should run out the end of the condensate  
drain line. If the water does not run out, call your qualified service technician to inspect  
the boiler and clean or replace the condensate drain line.  
4. To fill condensate trap, if necessary, temporarily plug the end of the condensate drain line.  
Then slowly pour water into the ½ inch plastic tee on boiler right side. Pour until water  
fills drain line, then overflows into the boiler trap tubing. When water fills up to top of ½  
inch tee, stop filling. Remove temporary plug from end of condensate drain line.  
1. See illustration at right.  
Check automatic  
air vents (if used)  
2. Remove the cap from any automatic air vent in the system and  
check operation by depressing valve “B” slightly with the tip of a  
screwdriver.  
3. If the air vent valve appears to be working freely and not leaking,  
replace cap A”, twisting all the way on.  
4. Loosen cap A” one turn to allow vent to operate.  
5. Have vent replaced if it does not operate correctly.  
7
Part number 550-100-027/0404  
GAS-FIRED WATER BOILER SERIES 2 — User’s Information Manual  
Maintenance procedures (continued)  
Periodically  
1. If the system is equipped with a low water cutoff, test the low water cutoff periodically  
Test low water  
cutoff (if installed)  
during the heating season, following the low water cutoff manufacturer’s instructions.  
Every 6 months  
1. Remove boiler front access door and perform gas leak inspection per steps 1 through 7,  
Check boiler piping  
(gas and water)  
Operating Instructions, page 9. If gas odor or leak is detected, immediately shut down  
boiler following procedures on page 9. Call a qualified service technician.  
2. Visually inspect for leaks around internal water piping. Also inspect external water piping,  
circulators, relief valve and fittings. Immediately call a qualified service technician to  
repair any leaks.  
Have leaks fixed at once by a qualifed service technician. Failure to comply  
could result in severe personal injury, death or substantial property damage.  
3. Replace door securely after inspections (see WARNING, page 6).  
Operate relief valve 1. Before proceeding, verify that the relief valve outlet has been piped to a safe place of  
discharge, avoiding any possibility of scalding from hot water.  
To avoid water damage or scalding due to valve operation, a metal discharge  
line must be connected to relief valve outlet and run to a safe place of disposal.  
This discharge line must be installed by a qualifed heating installer or service  
technician in accordance with the instructions in the Ultra Boiler Manual. The  
discharge line must be terminated so as to eliminate possibility of severe burns  
or property damage should the valve discharge.  
2. Read the boiler pressure/temperature gauge to make sure the system is pressurized. Lift  
the relief valve top lever slightly, allowing water to relieve through the valve and discharge  
piping.  
3. If water flows freely, release the lever and allow the valve to seat. Watch the end of the  
relief valve discharge pipe to ensure that the valve does not weep after the line has had  
time to drain. If the valve weeps, lift the seat again to attempt to clean the valve seat. If the  
valve continues to weep afterwards, contact your qualified service technician to inspect  
the valve and system.  
4. If water does not flow from the valve when you lift the lever completely, the valve or  
discharge line may be blocked. Immediately shut down the boiler, following the operating  
instructions on page 9. Call your qualified service technician to inspect the boiler and  
system.  
End of season  
1. Follow TO TURN OFF GAS TO 3. Do not drain the system if it is filled with  
Shut boiler down  
(unless boiler used  
for domestic water)  
APPLIANCE” on the page 9 of this  
an antifreeze solution.  
manual.  
4. DO NOT shut down boilers used for  
domestic water heating. They must operate  
year-round.  
2. Do not drain system unless exposure to  
freezing temperatures will occur.  
8
Part number 550-100-027/0404  
GAS-FIRED WATER BOILER SERIES 2 — User’s Information Manual  
OperatingInstructions  
FOR YOUR SAFETY READ BEFORE OPERATING  
If you do not follow these instructions exactly, a fire or explosion may result  
causing property damage, personal injury or loss of life.  
A. This appliance does not have a pilot. It is equipped with  
an ignition device which automatically lights the burner.  
Do not try to light the burner by hand.  
C. Use only your hand to turn the gas control knob. Never  
use tools. If the knob will not turn by hand, don't try to  
repair it, call a qualified service technician. Force or  
attempted repair may result in a fire or explosion.  
B. Before OPERATING, smell all around the appliance area  
for gas. Be sure to smell next to the floor because some  
gas is heavier than air and will settle on the floor. See  
below.  
D. Do not use this appliance if any part has been under water.  
Immediately call a qualified service technician to inspect  
the appliance and to replace any part of the control system  
and any gas control, which has been under water.  
WHAT TO DO IF YOU SMELL GAS  
Immediately call your gas supplier from a neighbor's  
phone. Follow the gas supplier's instructions.  
Do not try to light any appliance.  
Do not touch any electric switch; do not use any phone  
in your building.  
If you cannot reach your gas supplier, call the fire  
department.  
OPERATING INSTRUCTIONS  
1. Stop! Read the safety information above.  
This appliance is equipped with an ignition  
device which automatically lights the burner.  
Do not try to light the burner by hand.  
8. Turn ON POWER switch on the Ultra  
control panel.  
9. Set thermostat(s) to desired setting.  
10. The Ultra control panel display left digit  
will show a sequence of numbers (0, 1, 2,  
etc.) that indicate boiler control sequence.  
Digit 3 or 4 indicates boiler is firing.  
Digit 0 means there is no call for heat (all  
room thermostats and domestic water  
heater satisfied).  
2. Set room thermostat(s) to lowest setting.  
Verify external manual gas valve is open  
(valve handle parallel to gas piping).  
3. Turn OFF POWER switch on the Ultra  
control panel.  
4. Rotate two thumb screws at bottom of access  
door counterclockwise to release door.  
11. If the appliance will not operate when  
there is a call for heat and piping is not  
hot, follow the instructions "To Turn Off  
Gas To Appliance" below and call your  
service technician or gas supplier.  
5. Remove boiler access door.  
6. Turn boiler manual gas valve knob  
counterclockwise to open gas supply.  
7. Smell for gas in the boiler enclosure. If you  
smell gas, STOP! Follow "B" in the safety  
information above. If you don't smell gas,  
go to the next step.  
12. Replace jacket front panel. Make sure  
panel is seated firmly in place and all joints  
are visually sealed. Then tighten the two  
thumb screws at bottom of access door  
firmly.  
Boiler manual  
gas valve  
TO TURN OFF GAS TO THE APPLIANCE  
1. Set room thermostats to lowest setting.  
3. Close external manual gas cock (valve handle perpendicular  
to gas piping). Remove boiler access door. Turn boiler  
manual gas valve knob clockwise to close gas supply.  
2. Turn off all electric power to the boiler if service is to be  
performed. Turn OFF POWER switch on the Ultra  
control panel.  
4. Replace boiler access door.  
9
Part number 550-100-027/0404  
GAS-FIRED WATER BOILER SERIES 2 — User’s Information Manual  
Ultra boiler components . . .  
1. Cast aluminum heat exchanger  
2. Exchanger access cover  
3. Blower  
15. Gas connection pipe  
16. PhD Control Module  
16a. Top front cover  
4. Gas valve  
17. Transformer  
4a. Manual gas valve  
18. Air intake adapter  
4b. Gas valve sensing line  
5. Venturi  
19. Electrical entrance cover plate  
19a. Low voltage terminal strip  
19b. Line voltage terminal strip  
20. Boiler drain valve  
5a. Air inlet silencer  
6. Flue gas sensor  
7. Outletwatertemperaturesensor  
8. Returnwatertemperaturesensor  
9. Temperatureandpressuregauge  
10. Electronic display & buttons  
10a. On/off Power switch  
11. Flue pipe adapter  
21. Line voltage receptacle  
22. P/T gauge temperature sensor well  
23. Condensate drain connection  
"PVCtee)  
23a. Condensatetrap  
24. Front door  
24a. Thumb screws  
25. Ignitorelectrode  
26. Flame inspection window  
27. Data port  
12. Burner  
13. Water outlet pipe (system supply)  
14. Water return pipe (system return)  
10  
Part number 550-100-027/0404  
GAS-FIRED WATER BOILER SERIES 2 — User’s Information Manual  
GAS-FIRED WATER BOILER SERIES 2, WITH PhD TECHNOLOGY  
11  
Part number 550-100-027/0404  
GAS-FIRED WATER BOILER SERIES 2 — User’s Information Manual  
12  
Part Number 550-100-027/0404  

Westcott 1867 User Manual
Vista Davis & Sanford MARK2 User Manual
Sony WM FX195 User Manual
Sony Vario Sonnar T SAL 1680Z User Manual
Sony LSF H58 User Manual
Sony HANDYCAM DCR SR47 User Manual
Sony DCR IP1E User Manual
Sony CX520VE User Manual
Sony Car Stereo System CDX GT21W User Manual
Samsung Car Satellite TV System Series 5 User Manual