Half Gallon
Hi-Power Blender
MX1000R
INSTRUCTION BOOKLET
10. Keep hands and utensils out of container while blending to prevent the
possibility of severe personal injury and/or damage to the blender.
A rubber scraper may be used, but must be used only when the blender
is not running.
11. Blades are sharp. Handle carefully.
12. Always operate blender with cover in place.
13. When blending hot liquids, remove center piece of two-piece cover.
See Hot Blending Instructions.
14. The use of ear protection is recommended during extended
operating periods.
15. See Cleaning and Sanitizing Instructions for all Waring Pro® Blenders. NOT
FOR WATERJET CLEANING.
SAVE THESE INSTRUCTIONS
(
)
MX1000R Model: MXMPBKP6
BLENDER SPECIFICATIONS
• Capacity: 64 oz working capacity
• Switch Settings: (2 Speeds)
• Speed (RPMs)
Hi
Low
Pulse
30,000
26,000
30,000
• Rating: 120 Volts - 12.0 Amps
• Base Material: Polycarbonate
• Bearing: High Precision Ball Bearing
• Cord: 6 foot three-conductor ground cord with strain relief in base
• Overall Height: 19 inches
• Weight: 15 lbs
• UL, CUL, NSF listed
• Operating Cycle: 1 min. ON/3 min. OFF
GROUNDING INSTRUCTIONS
• For your protection, this appliance is equipped with a 3-conductor cord set.
• 120 volt units are supplied with a molded 3-prong grounding-type plug
(NEMA 5-15P) and should be used in combination with a properly connected
grounding-type outlet as shown in Figure 1.
If a grounding-type outlet is not available, an adapter, shown in Figure 2,
may be utilized to enable a 2-slot wall outlet to be used with a 3-prong plug,
except in Canada and Europe. Referring to Figure 3, the adapter must be
grounded by attaching its grounding lug under the screw of the outlet cover
plate.
Caution: Before using an adapter, it must be determined that the outlet cover
plate screw is properly grounded. If in doubt, consult a licensed electrician.
Never use an adapter unless you are sure it is properly grounded.
Note: Use of an adapter is not permitted in Canada and Europe.
Green/Yellow: Earth Ground. Blue: Neutral. Brown: Live.
Note: User installed cord set plugs are not permitted in Europe.
(
)
MX1000R Model: MXMPBKP6 OPERATION
1. Before starting, make sure that the blender is unplugged.
2. With the unit in OFF position, place container on blender base. Be sure
container is fully seated and that drive coupling is properly engaged. Plug
blender cord into outlet.
3. Put ingredients into container and cover it with
container lid. Do not fill above MAX line.
4. This blender has 2 speed settings: HI and LOW.
Press Paddle Switch to desired position. To crush
ice quickly, use HI speed setting.
5. When finished blending, set paddle switch to OFF
position.
6. This blender is equipped with a PULSE option. Hold paddle switch in
down position to engage PULSE function. Unit will run on HI speed until
the paddle switch is released.
7. Allow motor to come to a complete stop before removing container from
blender base. Never place the container on the motor base or remove it
from the motor base while motor is running.
8. Always hold container with one hand when starting and while blending.
Never operate without container lid.
9. Wash and dry container after each use. See Cleaning and Sanitizing
instructions.
IMPORTANT
HOT BLENDING INSTRUCTIONS
To minimize the possibility of being scalded when blending hot materials,
the following precautions and procedure must be observed.
• Hot materials are those which are 100°F (38°C) or hotter
• Limit the amount of materials processed to 1 pint (2 cups or 16 oz.)
• Completely remove the center portion of the two-piece container lid
before starting motor (This will allow venting of the rapidly heated and
expanding air inside the container when blender is running.)
• Always start blending on lowest speed setting, and then progress to
desired speed.
• Never stand directly over blender when it is being started or while it
is running.
CLEANING AND SANITIZING INSTRUCTIONS
THE CONTAINER MUST BE CLEANED AND DRIED AFTER EACH USE OF THE
BLENDER ACCORDING TO THE FOLLOWING INSTRUCTIONS. FAILURE TO
DO SO MAY ALLOW RESIDUES OF PROCESSED MATERIAL TO COLLECT
ON THE INTERNAL SEALS OF THE BLADE ASSEMBLY, RENDERING THEM
INEFFECTIVE.
• Wash, rinse, sanitize and dry container prior to initial use and whenever it
will not be used again within a period of 1 hour.
• Wash and rinse container after each use.
• Clean and sanitize motor base prior to initial use and after each use.
• Washing solutions based on non-sudsing detergents and chlorine-based
sanitizing solutions having a minimum chlorine concentration of 100 PPM
are recommended.
The following washing, rinsing, and sanitizing solutions, or their equivalents,
may be used.
SOLUTION
PRODUCT
DILUTION IN WATER TEMPERATURE
Washing
Diversy Wyandotte
4 Tablespoons
/Gallon
Hot 115˚F ( 46˚C )
®
*Diversol BX/a or CX/A
Rinsing
Plain Water
Warm 95˚F (35˚C)
Sanitizing
**Clorox®
1 Tablespoon/Gallon
Cold 50-70˚F
( 10-21˚C)
Institutional Bleach
*Diversol® is a registered trademark owned by the Diversey Wyandotte Corp.
**Clorox® is a registered trademark owned by the Clorox Company
• In repetitive batch-processing applications, frequent cleaning of the
container will prolong the life of the blade assembly. In no case should
actual running time between cleanings exceed 1/2 hour.
• Do not use container to store processed foods or beverages.
To Wash and Rinse Container:
1. REMOVE CONTAINER FROM MOTOR BASE. Remove lid. Rinse
container interior and lid under running water. Add washing solution to
container. Scrub and flush out the container interior and lid to dislodge
and remove as much food residue as possible. Empty container.
2. Wipe down exterior of container with a soft cloth or sponge dampened
with washing solution. Wash lid and lid insert in fresh washing solution. Fill
container 1/4 full with fresh washing solution, cover (with lid only), place on
motor base and run on “High” speed for two (2) minutes. Empty container.
3. Repeat step (2) using clean rinse water in place of washing solution.
IMPORTANT
NOTE: IN ORDER TO MINIMIZE POSSIBILITY OF SCALDING, TEMPERATURE
OF WASHING SOLUTION AND RINSE WATER MUST NOT EXCEED 115˚F
(46˚C), AND QUANTITY USED MUST NOT EXCEED 1/4 CONTAINERFUL.
IF HIGHER TEMPERATURES OR LARGER QUANTITIES ARE USED, OBSERVE
ALL PRECAUTIONS GIVEN IN THE OPERATING MANUAL UNDER “HOT
BLENDING INSTRUCTIONS”.
To Sanitize and Dry Container:
1. Wipe down exterior of container with a soft cloth or sponge dampened
with sanitizing solution.
2. Fill container with sanitizing solution, cover, place on motor base, and run
on high speed for two (2) minutes. Empty container. Dislodge any residual
moisture from blade assembly by placing empty container on motor base
and running on high speed for two (2) seconds.
3. Sanitize lid and lid insert by immersing in sanitizing solution for two
(2) minutes.
4. Do not rinse container, lid, or lid insert after sanitizing is completed. Allow
parts to air-dry.
To Clean and Sanitize Motor Base:
1. UNPLUG POWER CORD. Wipe down exterior surfaces of motor base with
soft cloths or sponges dampened with washing solution, rinse water, and
sanitizing solution. Prevent liquid from running into motor base by wring-
ing all excess moisture from cloths or sponges before using them.
DO NOT IMMERSE MOTOR BASE IN WASHING SOLUTION, RINSE WATER
OR SANITIZING SOLUTION.
2. Allow motor base to air-dry before using.
Waring Consumer Products
Division of Conair Corporation
150 Milford Rd
East Windsor NJ 08520
027302
Printed in USA
08WR200
PG-5378
|