Sony NSR 1000 User Manual

NSR-1000 Series  
NSR-1200/NSR-1100/NSR-1050H  
Version 1.1.1 Release Note 1st Edition  
Last Modified Date: Dec. 18th, 2009  
2009 Sony Corporation  
Index  
NSR-1000 Series v1.1.1 Release Note  
Overview  
This release note provides the information for the software of the NSR-1200 / NSR-1100  
/ NSR-1050H. For the built-in NSR Client (IMZ-NS Series) software, please refer to the  
release note of the RealShot Manager Advanced included in the client software.  
-Additional features by v1.1.1  
--Multiple Codecs support  
Newly supports multiple codecs for Sony IP network cameras and camera  
servers shown below.  
IP network camera (max. 3 codecs):  
SNC-RS44, SNC-RS46, SNC-RS84, SNC-RS86  
IP network camera (max. 2 codecs):  
SNC-RH124, SNC-RH164  
Camera server (max. 2 codecs):  
SNT-EP104, SNT-EP154, SNT-EX101, SNT-EX101E, SNT-EX104,  
SNT-EX154  
--Simple Motion Detection support  
Newly supports receiving a simple motion detection alarm of the following  
Sony camera servers as VMD (Camera).  
Camera server:  
SNT-EP104, SNT-EP154  
--H.264 Codec support  
Newly supports H.264 Codec for the Sony cameras. Please use the following  
firmware versions when you use H.264 Codec.  
Supported model name and firmware version are as follows:  
Camera Model Name  
SNC-RX530  
Camera Firmware Version  
v3.10/2.40 or higher  
SNC-RX550  
v3.10/2.40 or higher  
- 1 -  
         
NSR-1000 Series v1.1.1 Release Note  
SNC-RX570  
SNC-CS50  
SNC-RZ50  
SNC-DF50  
SNC-DF80  
SNC-DF85  
v3.10/2.40 or higher  
v2.30 or higher  
v2.40 or higher  
v1.20 or higher  
v1.20 or higher  
v1.20 or higher  
--Expansion of supported languages  
Newly supports Polish and Korean.  
-Built-in client software and software tools with NSR-1000 Series  
NSR-1000  
NSR Server Software  
Version  
NSR Client* [RealShot  
Manager Advanced (Client)]  
Version  
Media File Player Version  
Series Version  
V1.0.0  
V1.0.1  
V1.0.4  
V1.1.0  
V1.1.1  
1.0.0.26  
1.0.1.4  
1.0.4.6  
1.1.0.20  
1.1.1.7  
1.0.0.16  
1.0.1.4  
1.0.4.6  
1.1.0.19  
1.1.1.7  
1.2.0.7  
1.2.0.11  
1.2.1.5  
1.2.2.4  
1.2.3.0  
*Please refer to the installation manual to download the NSR Client Software from  
NSR-1000 Series via FTP.  
-Information for support client software and software tools  
Note  
Only Server/Client combinations written in same line of the following list are  
guaranteed.  
NSR-1000  
NSR Server Software  
Version  
Support NSR Client  
[RealShot Manager  
Media File Player Version  
Series Version  
Advanced(Client)] Version  
- 2 -  
     
NSR-1000 Series v1.1.1 Release Note  
V1.0.0  
V1.0.1  
V1.0.4  
V1.1.0  
V1.1.1  
1.0.0.26  
1.0.1.4  
1.0.4.6  
1.1.0.20  
1.1.1.7  
1.0.0.16  
1.2.0.7  
1.2.0.11  
1.2.1.5  
1.2.2.4  
1.2.3.0  
1.0.1.4*  
1.0.4.6*  
1.1.0.19  
1.1.1.7  
*New RealShot Manager Advanced is planned to be released.  
Please refer to the release note for the RealShot Manager Advanced and Media File Player  
which are included with RealShot Manager Advanced. The software version of the  
NSR-1000 Series which is supported by RealShot Manager Advanced is written in the  
release note. After Read the release note, if you need to upgrade to new one, you can get the  
software from web site.  
- 3 -  
NSR-1000 Series v1.1.1 Release Note  
-Support Camera Information  
Sony  
Camera Model Name  
SNC-CM120  
SNC-CS3  
Camera Firmware Version  
v1.02 or higher  
v1.08 or higher  
v1.06 or higher  
v1.06 or higher  
v1.02 or higher  
v2.24 or higher  
v1.18 or higher  
v1.15 or higher  
v1.18 or higher  
v1.15 or higher  
v1.15 or higher  
v1.02 or higher  
v1.02 or higher  
v1.02 or higher  
v1.02 or higher  
v1.29 or higher  
v1.29 or higher  
v1.04 or higher  
v1.04 or higher  
v1.04 or higher  
v1.04 or higher  
v1.04 or higher  
v1.04 or higher  
v3.03/2.33 or higher  
v3.03/2.33 or higher  
v3.03/2.33 or higher  
V1.30 or higher  
v3.14/2.24 or higher  
v2.23 or higher  
SNC-CS10  
SNC-CS11  
SNC-CS20  
SNC-CS50  
SNC-DF40  
SNC-DF50  
SNC-DF70  
SNC-DF80  
SNC-DF85  
SNC-DM110  
SNC-DM160  
SNC-DS10  
SNC-DS60  
SNC-P1  
SNC-P5  
SNC-RH124  
SNC-RH164  
SNC-RS44  
SNC-RS46  
SNC-RS84  
SNC-RS86  
SNC-RX530  
SNC-RX550  
SNC-RX570  
SNC-RZ25  
SNC-RZ30  
SNC-RZ50  
- 4 -  
 
NSR-1000 Series v1.1.1 Release Note  
SNC-Z20  
v1.06 or higher  
SNT-EP104  
SNT-EP154  
SNT-EX101  
SNT-EX101E  
SNT-EX104  
SNT-EX154  
SNT-V704  
v1.04 or higher  
v1.04 or higher  
v1.04 or higher  
v1.04 or higher  
v1.04 or higher  
v1.04 or higher  
v2.16 or higher  
Axis  
Camera Model Name  
Axis 206  
Camera Firmware Version  
v4.40  
v4.40  
v4.40.1  
v4.40  
v4.40.1  
v4.40  
v4.30  
v4.45  
v4.47  
v4.47  
v4.47  
v4.47  
v4.40.1  
v4.40.1  
v4.47  
v4.47  
v4.45  
v5.01  
v5.01  
v4.40  
v4.35  
Axis 207  
Axis 207W  
Axis 210  
Axis 210A  
Axis 211  
Axis 211A  
Axis 221  
Axis 209FD  
Axis 209FD-R  
Axis 209MFD  
Axis 209MFD-R  
Axis 216FD  
Axis 216FD-V  
Axis 216MFD  
Axis 216MFD-V  
Axis 225FD  
Axis P3301  
Axis P3301-V  
Axis 212PTZ  
Axis 212PTZ with CM  
- 5 -  
NSR-1000 Series v1.1.1 Release Note  
Axis 214PTZ  
Axis 215PTZ  
Axis 232D+  
Axis 233D  
v4.40  
v4.40  
v4.41  
v4.48.1  
v4.30  
v4.30  
v4.40  
Axis 241Q  
Axis 241QA  
Axis 241S  
IQinVision  
Camera Model Name  
IQeye510  
Camera Firmware Version  
v2.8/6(080313)  
v2.8/6(080313)  
v2.8/6(080313)  
v3.0/2(090521)  
v3.0/2(090521)  
v3.0/2(090521)  
v3.0/2(090521)  
v3.0/2(090521)  
v3.0/2(090521)  
IQeye511  
IQeye702  
IQeye703  
IQeye705  
IQeye711  
IQeye752  
IQeye753  
IQeye755  
- 6 -  
NSR-1000 Series v1.1.1 Release Note  
Important notes  
The cameras and camera servers listed below have some restrictions at V1.04  
firmware.  
SNC-RH series  
SNC-RS series  
SNT-EP series  
SNT-EX series  
The following are planned to be solved in a future release (V.1.06 or later).  
Periodical sending of VMF metadata is not executed.(V11N:520,  
V11R:735)  
After the execution of pan /tilt operation, notification of motion detection  
alarm is no longer issued.(V11R:740)  
Pan/tilt movement does not stop in some cases. (V11R:748)  
The simple motion detection alarm lasts only two seconds. (V11N:499)  
- 7 -  
 
NSR-1000 Series v1.1.1 Release Note  
Notes  
-Installation / System Configuration  
The NSR-1000 Series cannot connect with the client if the setting for ‘Network  
Interface for Remote Client’ on the ‘Server Configuration’ is configured as  
‘Network3’. Please set ‘Network1’ or ‘Network2’. (VT1:2036)  
If user changes the time zone setting on the ‘Setup Menu’ in the middle of  
operation such as schedule recording, scheduled recording setting or scheduled  
action setting change. In case of changing the time zone setting after  
configuring schedules, please make sure them and correct them if necessary.  
(VT1:2026)  
Only one USB mouse and/or one USB keyboard should be connected with the  
NSR-1000 Series. It is not recommended to connect more than one USB mouse  
and. or USB keyboard or use of KVM switch. (VT1:1868)  
Patch files consists of the two files. One is for the NSR software and  
the other is for the User's Guide. Be sure to apply these two  
patch files for upgrading the NSR to V1.1.0 (or later).  
Applying order can be arbitrarily determined. (V11N:314)  
-Download from the NSR-1000 Series  
If user downloads software tools such as the RealShot Manager Advanced,  
Media File Player, and User’s Guide from the NSR-1000 Series, user may not  
download with Internet Explorer as ftp client software. In this case, please  
download with not Internet Explorer but Explorer or other ftp client software.  
(VT1:2012)  
-Analog camera registration  
Maximum frame rate which can be set in all combinations of analog cameras  
using the NSBK-A16 has the following limitations. Please notice that the  
NSR-1000 Series with NSBK-A16 doesn’t allow to set over this limitation.  
(VT1:1800)  
- 8 -  
       
NSR-1000 Series v1.1.1 Release Note  
NTSC  
Resolution  
Maximum frame rate  
CIF(352x240)  
2CIF(704x240)  
4CIF(704x480)  
PAL  
480  
240  
120  
Resolution  
Maximum frame rate  
CIF(352x288)  
2CIF(704x288)  
4CIF(704x576)  
400  
200  
100  
User cannot change parameters about recording settings of analog cameras  
in the ‘Schedule Configuration’. Please change setting in ‘Video’ tab on  
‘Device Configuration’. These parameters are used as recording settings for  
‘Schedule Configuration’.  
-Device registration  
The camera servers SNT-EX104/EX154/EP104/EP154 can have different IP  
addresses by the video channels in it. For this reason, when registering two or  
more camera servers by specifying the IP address with the automatic camera  
registration or multiple camera registration features, a group of continuous IP  
addresses cannot be assigned to the one camera server.  
To prevent this, register a camera server one by one, or after specifying the IP  
addresses on the camera server in advance, register them with the multiple  
camera registration feature without specifying another IP address. (V11R:435)  
-Main Window - Search and Play back  
N/A  
-Main Window – Monitoring  
When the ‘Configuration Window’ or ‘Search Window’ is opened, the second  
display images are stopped. (VT1:1843)  
- 9 -  
     
NSR-1000 Series v1.1.1 Release Note  
"Smooth Scaling" function is available for only one monitor frame which is  
currently selected. This function is not applied to second display. (VT1:2069)  
The DIRECT PTZ function is not supported on camera servers SNT-EX/EP  
series connected to analog cameras. To achieve this function, use the buttons in  
the Camera Control pane or the remote controller. (V11N:401)  
-Main Window - Play back control  
The VMF detection frame is shifted from its expected position, if the VMF  
package which was used during recording does not exist in playing back the  
recorded image. (V11R:712)  
If a number of alarms occur continuously, multiple alarms look like combined  
on the timeline. Although user may not know switching alarms even if user  
clicks next/previous alarm button, user can make sure that switching by  
displayed time on the monitor frame. (VT1:1865)  
-Alarm Notification / Alarm History  
Alarm information during log off is not listed in the “Alarm History Pane”. To  
confirm such information, press Open Log Window on the Main screen and  
select Event/Alarm from the Log Type.(VT1:1897)  
When the SNT-V704 detects the sensor alarm, the number of channels  
registered to the NSR-1000 Series are listed in the alarm history at the bottom  
of the main GUI. (VT1:1707)  
-Search Window  
Up to 100 records which are searched in the search window can be deleted with  
selecting them at the same moment. Although user can select up to 1000  
records, it is recommended to select less than 100 records for stability behavior  
of the NSR-1000 Series. (VT1:1844)  
- 10 -  
     
NSR-1000 Series v1.1.1 Release Note  
You can select only the one check box in the search results list. Playback is  
enabled for the selected search result. Exporting is enabled for the selected  
search result, too. You can protect /unprotect the recordings if their background  
is turned into blue with the check box selected. (VT1:2163)  
-10 Device Configuration  
This section describes precautions on use of camera or setting. For other restrictions or  
precautions, refer to the User’s guide or release note for the camera.  
In case of using an alarm output function of the camera, enable its setting of  
the camera using Internet Explorer (Web browser) in advance(VT1:2037)  
Regarding following cameras, when user uses the VMD (Camera), codec setting  
shall be set as MPEG4. (VT1:1866)  
SNC-RZ25, SNC-P5, SNC-CS10, SNC-CS11, SNC-P1, SNC-DF70, SNC-DF40  
When the video format is configured as PAL for the NSR-1000 Series with  
NSBK-A16 for analog camera, please notice that the frame rate settings are  
converted to following settings, practically. (VT1:1804)  
Configured Actual frame rate  
frame rate  
NTSC  
1
PAL  
1
1
3
3
3.12  
5
5
5
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
8.33  
16.66  
20  
25  
N/A  
Note: As described in -, total frame rate is limited. When using PAL  
cameras, internal frame rate for calculation is different from the setting as  
described above. When configuring a system, please calculate with the  
- 11 -  
 
NSR-1000 Series v1.1.1 Release Note  
internal value not to over the limitation. (V11N:335)  
Regarding following cameras, if user use the VMD (Camera) with the codec as  
MPEG4, the frame rate is limited as 20FPS with NTSC or 16FPS with PAL. If  
VMD (Camera) is disabled after enabled, maximum frame rate setting becomes  
available after other resolutions are selected once. (VT1:2016)  
SNC-RZ50, SNC-CM120, SNC-CS50, SNC-CS20, SNC-DM160, SNC-DM110,  
SNC-DS60, SNC-DS10, SNC-DF85, SNC-DF80, SNC-DF50, SNC-RX570,  
SNC-RX550, SNC-RX530  
When you configure masks for a camera which is now recording images, the  
mask area shifts as expected for the live images, however, recording continues  
with the original mask setting at the beginning of recording. To enable the  
mask function in recording, be sure to deselect the [Enable] check box to enable  
the schedule on the Record dialog box, and then select it to apply. (VT3:830)  
When you do the Automatic Alarm Schedule Configuration, schedule is  
configured with the setting in [Video] tab. (VT1:2068)  
Note that some cameras do not support the camera direct panning/tilting  
function and area zoom function. If you use the encoder together with the  
cameras, check the manual to see if the cameras to be used support the above  
functions. (VT2:776)  
There are some restrictions when H.264 is selected for the cameras below:  
SNC-CS50, SNC-DF50, SNC-DF80, SNC-DF85,  
SNC-RX530, SNC-RX550, SNC-RX570, SNC-RZ50  
Another codec cannot be selected at the same time.  
VMD(Camera) and VMF function does not work despite those settings are  
available in the [VMD] tab of the configuration screen. Please use the  
VMD(Recorder) when H.264 is selected.  
- 12 -  
NSR-1000 Series v1.1.1 Release Note  
The image size of more than QVGA(320x240) is selected, the maximum  
frame rate is limited at the transmission side as follows:  
NTSC: 10 fps or less  
PAL:  
8 fps or less  
If the cameras mentioned below uses the MPEG4 codec with the image size of  
more than 384x288, the maximum frame rate is limited at transmission side.  
(V11N:59)  
SNC-CS50, SNC-DF50/DF80/DF85, SNC-RX530/RX550/RX570, SNC-RZ50  
15(NTSC)/20(PAL) fps or less with the stabilizer set to on  
20(NTSC)/16(PAL) fps or less when the dual codec including JPEG and  
anything is selected, or while the motion detection is working  
When you want to select the image size of more than 4CIF on the SNC-DF85,  
the firmware version of the camera should be V1.20 or higher. If the former  
version, do not select 4CIF in the image size setting. (V11N:226)  
To configure the camera protocol on camera servers SNT-EX series connected to  
analog cameras, access the setting page through the web browser of the  
SNT-EX series. (V11N:169)  
With regard to the SNT-EX154, audio data of channel 1 only is output through  
CH1 AUDIO OUT connector of the SNT-EX154.(V11N:283)  
I/O pins of the SNT-EX series are shared with all the video channels. It is  
possible for the channel 1 to use all the I/O pins, or for each channel to use each  
pin one by one.  
If the output pins are shared with two or more video channels, there may be  
some inconsistencies occurring. To work around this, it is recommended to  
assign output pins to any one of the channels. (V11N:284)  
The detection area configuration in the VMD (Camera) Configuration screen is  
performed based on the VGA (640x480) coordinate system. Note that it shows  
- 13 -  
NSR-1000 Series v1.1.1 Release Note  
values different from actual ones when making configurations for the  
cameras/camera servers shown below (V11R:483)  
SNC-RH series  
SNC-RS series  
SNT-EP series  
SNT-EX series  
In this case, perform the adjustment of the detection area size while viewing  
on the frame in the configuration screen.  
When parameters in the Video setting tab are changed while recording, it will  
affect the recording like the followings. (V11N:155)  
Manual Record  
All parameters in the Monitoring are reflected to the recording.  
Schedule Record, Event/Alarm Record  
In case Codec is changed  
The change is reflected to the recording.  
By this change, if a combination of settings in the Schedule tab become  
inappropriate, settings in the Video tab are reflected to the recording  
automatically.  
However the internal change will not reflected in the Schedule tab.  
In case Size/Bitrate/Framerate is changed  
In case "Device Setting" is set in the Schedule tab  
The change is reflected to the recording.  
In case settings are already specified in the Schedule tab  
Settings in the Schedule tab are given priority to the Video tab.  
And the settings are reflected when the schedule starts.  
When registering many (e.g. 64) cameras with Multiple Camera Registration at  
one time, NSR performance becomes worse for a while. In such condition, if you  
log off NSR and log on again, it may fail. Please wait several minutes after  
- 14 -  
NSR-1000 Series v1.1.1 Release Note  
registration. (V11N:461)  
-11 Action Configuration  
N/A  
-12 Schedule Configuration  
If user sets the schedule record of following cameras with the ‘Automatic  
Record Configuration’, the codec setting shall be not MPEG4 but JPEG. If user  
needs to change the setting, please select the codec on ‘Video’ tab in the Device  
menu. (VT1:1690)  
SNC-CM120, SNC-CS20, SNC-DF85, SNC-DM110, SNC-DM160, SNC-DS10,  
SNC-DS60  
If user changes the ‘Storage Setting’ of the camera during recording, new  
storage setting has not been available for recording. Following steps are  
recommended to change the storage setting. (VT1:1646)  
1. Disable the schedule setting. (Uncheck ‘Enable’ check box on the top of the  
schedule configuration window)  
2. Change ‘Storage Setting’  
3. Enable the schedule setting. (Check ‘Enable’ check box on the top of the  
schedule configuration window)  
If user enables audio setting to the camera during recording, it is not available  
to record audio of it. It is necessary to enable audio setting before starting to  
record in order to record audio. (VT1:1643)  
If user adds the camera to the existing schedule, the ‘recording cameras box’  
may be blank. In this case, this recording schedule is not available. It is  
necessary to reacquire settings of cameras with the ‘Adjust to camera  
configuration’ button. (VT1:1441)  
If user changes the system time during recording, the time of recorded data  
shall change with this change. There may be problems that the duration  
- 15 -  
   
NSR-1000 Series v1.1.1 Release Note  
between start and stop time of recording is too long or the time displayed on the  
monitor frame jumps suddenly. Please change the system time after stopping to  
record. (VT1:1659)  
-13 User Configuration  
If user set the username and password except English one byte characters, [-],  
and [_], user cannot log on with the username and the password. In this case,  
please log on with administrative privileges and change the username and the  
password. (VT1:1693)  
-14 Layout Configuration  
In the Layout Configuration, the “Deinterlace” setting should be ON (checked)  
as the default in version 1.0.4. If user update from previous software version to  
this, "Deinterlace" is not automatically ON. In this case, please make a check in  
the "Deinterlace" box on the Layout Configuration with confirming setting of  
the layout which has already been created. (VT1:2096)  
-15 Log Window  
N/A  
-16 Export  
User can select records up to 100 to export at the same time. (VT1:1845)  
-17 3rd Vendor Camera  
When you want to use the mask function for the AXIS camera/video server,  
configure masks on the camera/video server side, not on the recorder side.  
(VT1:2132, VT3:950, 926)  
When the PTZ operation is carried out for a AXIS PTZ camera where the  
VMD(Recorder) is configured, motion is detected even during PTZ operation of  
the camera itself. (VT3:940)  
- 16 -  
         
NSR-1000 Series v1.1.1 Release Note  
When you change the video-related options (Image Size, Image Quality and  
Frame Rate) on the [Video] tab while monitoring/recording a JPEG image an  
AXIS camera is capturing, monitoring or recording may continue with the  
previous settings. To enable the changed values in monitoring, be sure to logoff  
once, and then logon. To enable the changed values in recording, be sure to  
deselect the [Enable] check box to enable the schedule on the Record dialog box,  
and then select it to apply. (VT3:914)  
When you configure the e-flip for an AXIS camera of which codec is set to JPEG,  
monitoring or recording may continue without the video flipped vertically. To  
enable the e-flip in monitoring, be sure to logoff once, and then logon. To enable  
the e-flip in recording, be sure to deselect the [Enable] check box and apply,  
select the [Enable] check box again to enable the schedule on the Record dialog  
box, and then select it to apply. (VT3:912)  
AXIS camera’s preset name can’t be changed to other name after it was set.  
Please delete it and set it again. (VT1;2159)  
The DIRECT PTZ function is not supported on AXIS video servers or PTZ  
cameras. To achieve this function, use the buttons in the Camera Control pane  
or the remote controller. (V11N:400)  
AXIS camera acquires images by RTSP using port 554 when MPEG4 codec is  
selected. Therefore, when using AXIS camera with the codec set to MPEG4, do  
not disable RTSP on the camera. And keep the port number default  
(automatically). (V11N:409)  
In addition, when using AXIS camera with the codec set to MPEG4,  
connection via Proxy is impossible, because the NSR-1000 series supports only  
the HTTP Proxy server in connection with the camera.  
When you want to connect to the camera via Proxy, set the codec to JPEG.  
(V11N:411)  
With IQinVision camera with 2M pixels, the frame rate may halve compared to  
- 17 -  
NSR-1000 Series v1.1.1 Release Note  
the value specified by “Frame rate”. It also depends on combination of image  
size and frame rate. (V11R:58)  
Before use, be sure to check whether an image is output at the specified frame  
rate. If not, reconfigure the image size or frame rate to the other value.  
It has been confirmed that this issue happens in the following combinations.  
Confirmed firmware version is v3.0/2 in all cases.  
IQeye752 (max. image size1600x1200):  
Output at 10 fps when the image size (800x600) and frame rate  
(20fps) are being specified.  
IQeye753 (max. image size 2048x1536):  
Output at 6 fps when the image size (1024x768) and frame rate  
(12fps) are being specified.  
IQeye755(max. image size 2560x1920):  
Output at 5 fps when the image size (1280x960) and frame rate  
(10fps) are being specified.  
-18 Other  
N/A  
- 18 -  
 
NSR-1000 Series v1.1.1 Release Note  
Limitations  
-Known Limitations  
--Installation / System Configuration  
When enabling the SNMP agent function under [Administration] menu ->  
[Setup] menu -> [SNMP Menu] ->[Trap], the error message below is displayed  
and the ERROR lamp is lit.  
There is no problem in operation, however, because it is displayed when  
service automatically restarts itself. (V11N:165)  
wixalarm[1234] is dead or killed  
--Device Registration  
Devices which have already been registered may be displayed on ‘Unregistered  
Cameras’ list in ‘Open the Multiple Camera Registration Window’. In this case,  
please update the list with ‘Reload’ button. (VT1:764)  
--Main Window - Search and Play back  
Audio cannot be output when playing audio in files which is currently recorded  
from search result. (VT1:1668)  
If user tries to start playback with selecting alarm history after change layout  
from the one to 1x1 with double-clicking the monitor frame, the layout is back  
to former layout. Please start playback with selecting alarm history except 1x1  
layout and double-click the monitor frame to display 1x1. (VT1:1689)  
During quick playback, when clicking [Go] button after specifying nonexistent  
date and time on the main screen, a message “No Record” appears and the  
mode is restored from [PLAYBACK] to [LIVE].(V11N:20)  
[S/C] When playing back the images just before recorded while recording,  
playback may pause within a few minutes. To resume playback, press the PLAY  
button. (V11N:25)  
If you specify “iSCSI” as recording storage, and specify “00:00:00 to 24:00:00”  
- 19 -  
         
NSR-1000 Series v1.1.1 Release Note  
for continuous recording, it takes more than ten minutes to load the recorded  
data since [PLAYBACK] is pressed. When you want to select “iSCSI” as  
recording storage, it is recommended to segment the record by setting a  
recording schedule that inserts a 1 -second recording break each day in the  
recurrent schedule of the normal recording. (V11N:38)  
e.g.) Start time: 00:00:00 End time: 23:59:59  
--Main Window – Monitoring  
There is a problem that FPS value decreases slightly each time recording  
starts/stops. This happens when a different video setting is made for the  
monitoring setting and scheduled recording setting. (V11R:625)  
When focus or bright adjustment is carried out during recording, frame loss  
may occur. (V11N:489)  
If the hotspot and a Monitor Frame during PLAYBACK exist in one layout,  
when the Monitor Frame is selected, audio cannot be output. Please do  
PLAYBACK after selecting and activating the monitor frames other than the  
hot spot when it is an active monitor frame. (VT1:2247)  
The value of Focus, Brightness and Day/Night in [Adjust] tab at [Camera  
Control] pane are not updated when these values are changed from other  
clients or browser. (VT2:750)  
While executing the VMD (Recorder) motion detection function, there are cases  
where any one of the four sides of a rectangular motion detection frame is not  
displayed when it overlaps with a moving object. This issue happens when the  
image size is set to more than 1280x960. (V11N:44)  
Even if you select [MANUAL ACTION] in the Device menu, the manual action  
list is not displayed on the NSR screen. To display the list, put the RM-NS1000  
into the mouse mode, and select [Manual Action] in the Manual Action pane at  
the top right of the screen of NSR. (V11N:207)  
- 20 -  
 
NSR-1000 Series v1.1.1 Release Note  
When recording audio from a camera of which frame rate is set to less than 1fps,  
you cannot play back audio in synchronization with image. For example, in case  
of 0.25fps, a four-second image is played back per a frame. On the other hand,  
with regard to audio, a one-second audio is repeatedly played back four times  
per a frame. (V11N:368)  
Using the following cameras, monitoring images stops for a several seconds just  
after the camera preset tour starts or stops. During the preset tour, the  
images can be received normally. (V11N:450)  
SNC-RH series  
SNC-RS series  
--Analog Camera Control  
Using Camera Control Pane or Remote Controller, do NOT perform  
PTZ/FOCUS/BRIGHT operations for analog cameras without PTZ function,  
although they look available. If you try to do accidentally, the system stops  
monitoring/recording images for a few seconds.(VT1:1895)  
There are the following restrictions for the analog camera that is supporting  
the PTZ function. (V11N:86,V11N:400)  
Some analog cameras do not support the auto focus function. Use the  
manual focus function for such cameras  
The DIRECT PTZ function is not supported. To achieve this function, use  
the buttons in the Camera Control pane or the remote controller.  
If a mask to hide a specified area is configured on the screen, it is fixed and  
does not move in conjunction with the camera’s pan, tilt and zoom  
movements. So do not use the mask function when you want to use the PTZ  
function of the camera.  
When performing pan, tilt and zoom with an analog camera for which the  
VMD(Recorder) is configured, the motion is accidentally detected even  
during PTZ operation by the camera.  
- 21 -  
 
NSR-1000 Series v1.1.1 Release Note  
--Alarm Notification / Alarm History  
If user tries to play back the camera with double-clicking alarm history during  
playing back it on the other monitor frame, the NSR-1000 Series cannot start to  
play back and live image is displayed. Please make sure that the camera is not  
played back on other monitor frames when user starts to play back it.  
(VT1:1687)  
When configuring the alarm recording triggered by other device than a camera,  
like the sensor inputs in NSR or Barionet , you can see the trigger name only in  
the alarm history even when alarms occurred. (No camera name is displayed.)  
In addition, the recorded image cannot be played back by double-clicking each  
alarm history. To playback, search the desired record and play it from the  
search results. (V11N:253, V11N:257)  
--Search Window  
If user searches again, recorded data which has been deleted may be displayed  
on the ‘Timeline Result’ shortly after the deletion. In this case, that deleted  
data does not appear after searching again. (VT1:1916)  
The Previous Frame and Next Frame button on Playback Control Pane of  
Search window control the selected monitor frames.(VT1:1757)  
--Device Configuration  
The NSR-1000 Series registers cameras as PAL right after registration even if  
these cameras only have NTSC mode. In this instance, the frame rate list of the  
camera is same as the list of PAL. If user once displays live image of the camera  
on the configuration window or Main GUI, the NSR-1000 Series identifies  
appropriate video format as either NTSC or PAL and updates the list.  
(VT1:1251)  
If analog video data is input to the NSR-1000 Series via NSBK-A16, 0.25fps /  
0.33fps / 0.5fps can be selected from the list of frame rate. But these settings  
are available when codec setting is only MPEG4(I frame). When MPEG4 is  
- 22 -  
     
NSR-1000 Series v1.1.1 Release Note  
selected, actual frame rate is 1fps. (VT1:1842)  
You can change multiple registration details by selecting two or more cameras  
at time, if they are all the same model. If 29 or more cameras are selected,  
however, there are cases where the maximum value cannot be selected from the  
list. To work around this, select up to 28 cameras. (V11N:43)  
When changing any value on [Video] tab on Device Configuration Screen, be  
sure to press “Apply” button before moving to the other tab. If you do so without  
pressing “Apply” button, when you return to [Video] tab, you can see the value  
just before changing. If you press “Apply” button from the above situation,  
however, the changed value (different from the displayed one) is applied.  
(V11N:61)  
When configuring masks with [Freeze image during PTZ movement] selected  
for the cameras with the PTZ functions, rendering is stopped during PTZ  
movement if there is any mask(s) in the area, and it continues if not. In the case  
that the PTZ movement is performed across the areas without and with masks,  
rendering starts and then stops at the timing when the camera enters the area  
including the mask.  
If the PTZ movement is too fast to stop rendering in such case, rendering may  
continue even in the area including the mask. To work around this, let the  
camera slowly move to the area including the mask. When configuring masks,  
be sure to adjust the width and height of the mask while checking the PTZ  
movement. When configuring the camera tour, be sure to check the mask size  
and the speed of the tour. (V11N:150)  
When opening the configuration screen just after registering the following  
cameras/camera servers, some tabs like [Physical Sensor In] may not be  
displayed. Or the parameters for PAL model may be listed under Image Size or  
Frame Rate on [Video] tab regardless of use of NTSC camera. To work around  
this, confirm that the image is monitored by clicking [General] tab, select  
another camera once in the camera tree and then reselect the target camera.  
- 23 -  
NSR-1000 Series v1.1.1 Release Note  
(V11N:363,V11N:446)  
In addition, when making the Device configuration settings continuously,  
there are infrequent cases where a part of set values etc., is not displayed by  
screen refresh even after the settings are applied. In this case, select another  
camera once in the camera tree and then reselect the target camera.  
(V11R:521)  
SNC-RH series  
SNC-RS series  
SNT-EP series  
SNT-EX series  
Using the following cameras/camera servers, the preview feature of the motion  
detection is not activated in the Configuration window while configuring the  
VMD(Camera). To pre-check the motion detection, apply the settings, return  
the main screen and assign the target camera to any of monitor frames.  
(V11N:304)  
SNC-RH series  
SNC-RS series  
SNT-EP series  
SNT-EX series  
When changing a camera name on [General] tab after camera registration, the  
set values may be displayed blank. In this case, close the Device configuration  
screen once, and then re-open it. (V11N:383)  
When specifying a preset name for the following cameras/camera servers, a  
space cannot be used in the preset name.(V11N:399)  
SNC-RH series  
SNC-RS series  
SNT-EP series  
SNT-EX series  
After changing resolution settings for a camera which has some masks, please  
- 24 -  
NSR-1000 Series v1.1.1 Release Note  
set up masks again. (V11R:484)  
--Server Configuration  
Pay attention to the followings when you want to change the recording storage  
from default to other in the storage settings. It affects the estimation of storage  
capacity.  
When the storage mode is put into the camera mode (refer to “Configuring  
Storage for Each camera ([Camera] mode) in the User’s Guide, for details.),  
audio data is saved in default storage even if changing the recording storage  
from default.  
When the storage mode is put into the recording type mode (refer to  
“Configuring Storage for Each recording type ([Recording Type] mode) for  
details.), audio and image data are saved in the specified and same storage.  
(V11R:272)  
--10 Action Configuration  
When configuring a beep tone so that it sounds by being triggered by the  
schedule, the beep sounds briefly and it is hard for an operator to notice it.  
When you want to know the trigger occurrence for certain, configure the alarm  
recording and confirm the trigger occurrence in the alarm history. (V11N:107)  
--11 Schedule Configuration  
When the scheduled recording is configured for the cameras or camera servers  
listed below, recording starts a few seconds behind the scheduled time.  
(V11R:638)  
SNC-RH series  
SNC-RS series  
SNT-EP series  
SNT-EX series  
When a load of disk writing is very high in a server, an alarm recording stops  
shorter than estimated in rare cases. Please set a record duration longer.  
(V11R:759, V11N:543)  
- 25 -  
     
NSR-1000 Series v1.1.1 Release Note  
If user modifies recording settings in ‘Schedule Configuration’ such as alarm to  
event, the NSR-1000 Series doesn’t reload the default recording settings (codec  
/ Image Size / Image Quality / Bit Rate / Frame Rate) on ‘Video’ tab in the  
‘Device Configuration’ automatically. Please click ‘Adjust to Camera  
Configuration’ at the bottom of ‘Schedule Configuration’ Window and reload the  
last settings manually. (VT1:1925)  
The NSR-1000 Series has the following limitation of the number of cameras to  
be set as alarm recording because of avoiding overload in ‘Automatic Alarm  
Recording’. (VT1:1749)  
NSR-1200 - up to 24 cameras  
NSR-1100 - 12 cameras  
NSR-1050H – 12 cameras  
In the Schedule Configuration, after closing the “New Action” dialog, when  
"Close" button is clicked without pressing "Apply" button, a confirmation  
message will not be displayed. Preservation is done without the preservation  
confirmation message appearing, and set it to former setting again, please  
when you want to cancel at that time. (VT1:2243)  
When configuring the schedule for the event/alarm recording, you can specify  
all triggers configured for NSR (regardless of whether the camera is used for  
the record or not) by selecting “Show All Triggers” select box.  
When displaying the configuration again after the settings are saved, however,  
you can see that this check box become unchecked. To confirm the trigger status,  
again check this “Show All Triggers” check box. (V11N:241)  
The problem that the system is used in an area where daylight saving time  
(DST) is in effect. After DST starts/ends, actions triggered by the schedule do  
not work properly. To prevent this, be sure to restart the system and  
reconfigure the action schedule after switching over DST. (V11R:560,V11R:561)  
- 26 -  
NSR-1000 Series v1.1.1 Release Note  
Otherwise, the following issues occur:  
-An hour is given or taken for the schedule which triggers actions.  
-Time indication in the alarm history is read an hour behind or early.  
Note that you cannot play back by clicking the alarm history where the  
improper time is displayed.  
To work around this, play it from the search results.  
--12 User Configuration  
N/A  
--13 Layout Configuration  
N/A  
--14 Export  
In case of playing the media where the recorded images with audio are exported  
from RealShot Manager Advanced (server/client) or NSR-1000 series, the audio  
data may not be played back depending on the PC environment. In this case,  
please install Media File Player to the PC environment before playing the  
media (VT2:507)  
When capturing a screenshot as a still image, if the image size is set to  
CIF/4CIF, its aspect ratio is automatically shrunk to 4:3 and is converted to  
JPEG file.  
In case of VGA(640x480) whose aspect ratio is 4:3, it is converted without being  
shrunk to JPEG file.  
(e.g.)  
NTSC/CIF(352x240) case: 320x240  
PAL/CIF(352x288) case: 352x264  
If the image size is set to 2CIF, it is converted to 4:3 by reference to the height  
of the screen. (V11N:37)  
(e.g.)  
NTSC/2CIF(704x240) case: 320x240  
- 27 -  
     
NSR-1000 Series v1.1.1 Release Note  
PAL/2CIF(704x288) case: 384x288  
--15 Other  
N/A  
- 28 -  
 
NSR-1000 Series v1.1.1 Release Note  
-Resolved limitations in V1.1.1  
There were some restrictions in V1.02 of the cameras/camera servers below.  
(V11R:386,V11R:440,V11N:379)  
SNC-RH series  
SNC-RS series  
SNT-EP series  
SNT-EX series  
The restrictions mentioned below have been solved in V.1.04.  
When executing the preset function, detections by VMD(Camera) and VMF  
don’t work.  
Overwrite recording during the shadow tour may be disabled during a  
certain period.  
If clicking the monitor frame while the live images are monitored with  
audio enabled, the live images freeze for about three seconds.  
Audio may be interrupted intermittently.  
RM-NS1000 was not detected correctly when connected to NSR-1000 series.  
This caused a message “Unsupported Device” to be displayed and ERROR lamp  
to light. (V11N:479)  
This issue has been solved.  
There was a problem that the pan/tilt movement did not stop for a certain  
period after RM-NS1000 performed pan and tilt controls for SNC-RH164.  
(V11R:596)  
This issue has been solved.  
There was a problem that the camera’s pan/tilt movement was uncontrollable  
for a certain period if you pressed IRIS button (or MANUAL FOCUS button)  
continuously for adjustment. (V11R:601)  
This issue has been solved.  
There was a problem that any monitor frame number was not displayed in the  
- 29 -  
 
NSR-1000 Series v1.1.1 Release Note  
monitor frames on the NSR even when you pressed MONITOR SELECT button.  
(V11N:478)  
This issue has been solved.  
There was a problem that communication with the slave server was not  
established after you upgraded the NSR-1000 series or RealShot Manager  
Advanced which configured the master/slave configurations, from v1.0.4 to  
v1.1.0. (V11N:473, V11R:582)  
This issue has been solved.  
When you initiated to play back the file during a prolonged recording, it was  
less responsive. (V11N:38)  
While the recorded image was being played back, the VMF detection frame was  
not rendered correctly in size. This happened when the VMF settings were  
configured for the cameras or camera servers listed below. (V11R:583)  
SNC-RH series  
SNC-RS series  
SNT-EP series  
SNT-EX series  
This issue has been solved.  
There was a problem that the whole screen froze at the timing of clicking  
“PALYBACK” on the main screen. (V11N:491)  
This issue has been solved.  
“Threshold” and “Hold Time” settings for Light Funnel mode were unavailable.  
(V11N:513)  
This issue has been solved.  
When the VMF settings were configured, VMF detection frame was sometimes  
not displayed during playback on the main screen. (V11R:711)  
This issue has been solved.  
- 30 -  
NSR-1000 Series v1.1.1 Release Note  
There was a problem that live image is not displayed depending on the video  
codec settings on the SNC-RH series camera. (V11R:745)  
This issue has been solved.  
Example of video codec settings that cause the trouble:  
H.264, 4096kbps, 1fps  
H.264, 8192kbps, 1fps  
H.264, 8192kbps, 2fps  
When SNC-DF85 are being used with the RealShot Manager Advanced of less  
than v1.1.0.19 with JPEG codec and then, you upgrade it to v1.1.0.21, this may  
change the video codec settings to MPEG4 for the cameras. (V11R:578)  
This issue has been solved.  
- 31 -  
NSR-1000 Series v1.1.1 Release Note  
Appendix  
-Histories of additional features  
--Additional features by V1.1.0  
---Expansion of supported cameras  
Newly supports the Sony IP network cameras and camera servers shown below.  
IP network camera:  
SNC-RS44, SNC-RS46, SNC-RS84, SNC-RS86, SNC-RH124, SNC-RH164  
Camera server:  
SNT-EP104, SNT-EP154, SNT-EX101, SNT-EX104, SNT-EX154  
Major new feature supported by the NSR-1000 series are as follows:  
H.264 Support  
Camera Tampering Detection  
Shadow Tour  
Visibility Enhancer  
XDNR  
For the further information about restrictions or precautions with regard to the  
network cameras /camera servers, see later in this document.  
In addition, IQinVision cameras shown below are newly supported.  
IQeye510, IQeye703, IQeye705, IQeye711, IQeye752, IQeye753, IQeye755  
For details of other supported cameras, refer to -”Support Camera Information”.  
---System Controller RM-NS1000 support  
Newly supports the Sony System Controller RM-NS1000. For details, refer to the  
Quick Setup/Start Guide and User’s Guide which come with the product.  
---iSCSI storage support  
Newly supports the iSCSI RAID as external storage for the NSR-1000 series. For the  
further information of installation, connection, etc., refer to the technical document  
which will be separately available and Installation Manual /User’s Guide which  
come with the product.  
- 32 -  
     
NSR-1000 Series v1.1.1 Release Note  
---4CIF resolution support  
Newly supports 4CIF resolution (PAL: 704x576, NTSC: 704x480) for the Sony IP  
network cameras.  
Supported model name and firmware version are as follows:  
Camera Model Name  
SNC-RX530  
SNC-RX550  
SNC-RX570  
SNC-CS50  
Camera Firmware Version  
3.10/2.40 or higher  
3.10/2.40 or higher  
3.10/2.40 or higher  
2.30 or higher  
SNC-RZ50  
2.40 or higher  
SNC-DF50  
1.20 or higher  
SNC-DF80  
1.20 or higher  
SNC-DF85  
1.20 or higher (*1)  
*1 When you want to select the image size of more than 4CIF on SNC-DF85,  
the firmware version of the camera should be V1.02 or higher. If the former  
version, do not select 4CIF in the image size setting.  
---Highlight function  
Newly supports the highlight function that displays flashing red frames around  
images in the custom layout at the occurrence of related alarm/event. For details,  
refer to the User’s Guide.  
---Auto-logon function  
Newly supports the auto-logon function that allows you to be logged on without being  
certificated by the NSR-1000 series at start-up. For details, refer to the User’s Guide.  
---ONVIF support  
Newly supports ONVIF Version 1.01.  
Auto Registration and Multiple Camera Registration are not supported.  
Please specify a Device Type "ONVIF".  
Only supports JPEG streaming.  
It is not guaranteed to connect to all ONVIF V1.01 conformant products.  
- 33 -  
NSR-1000 Series v1.1.1 Release Note  
--Additional features by V1.0.4  
Object  
Improvement  
Server/Client AXIS and IQinVision cameras are supported. (VT1:2072, 2099)  
Client Audio Upload From a Client is supported. (VT2:728)  
Server/Client Specifying Camera and Server with Host Name is enabled. (VT1:2095,  
VT3:863)  
Server/Client All Monitor Frames Function on the Monitor Control pane is enabled.  
(VT1:2083, VT2:736)  
Server/Client [Close] button in the right-bottom on each configuration screen is  
added.(VT1:2104, VT3:871)  
Server/Client Disabling audio recording function during audio monitoring is added.  
(VT1:2094, VT2:870)  
Server/Client Tool Hint function on the GUI is supported.(VT1:2109, VT3:866)  
Client  
The [Resume time on inactivity] setting is enabled on the Camera tour  
configuration screen.(VT2:855)  
Server/Client The E-flip(Recorder) function for all cameras is supported. (VT1:2061,  
VT3:850)  
Server/Client Event information is added in the e-mail from action. (VT1:2087, VT3:934)  
Server/Client The Installer of the Media File Player is able to be exported.  
--Additional features by V1.0.1  
Object  
Server  
Improvement  
The preparation time for play back in case of having a lot of records is  
shorter than previous software release. (VT1:1864)  
Audio quality from NSR-1000 Series is enhanced. (VT1:1951)  
Monitoring display at 1920x1200 resolution is enlarged. (VT1:1578)  
Server  
Server  
Server/Client How to choose searched records to export is more intuitive. (VT1:1966)  
Server/Client ‘Resume time on inactivity’ on the camera tour configuration menu can be  
selected for restart camera tour. (VT1:1276)  
- 34 -  
   
NSR-1000 Series v1.1.1 Release Note  
Server/Client The NSR-1000 Series and the client software start to support controlling  
PTZ of analog camera via VISCA protocol. (VT1:1911)  
- 35 -  
NSR-1000 Series v1.1.1 Release Note  
-Histories of resolved limitations  
--Resolved limitations in V1.1.0  
---Main Window – Monitoring  
There are cases where a camera does not move even if you select the preset  
position which is already configured and appears in the preset list. This  
problem may happen when you move a camera in the ways other than selecting  
the preset position after moving it to the present position once on the main  
screen. To work around this, select the other position once and then reselect the  
desired position in the preset list. (V11N:76)  
---Device Configuration  
If specifying an IP address which is not connected to the camera and clicking  
[OK] button, it takes about ten minutes to detect the error. (V11N:9,V11N:27)  
If registering two or more Barix-made Barionet I/O devices, all pins  
incorporated in all the registered Barionet devices are displayed in random  
order under [Barionet] in the device tree. To work around this, use the single  
Barionet device. (V11N:78)  
When manual recording is performed when monitoring an AXIS camera with  
MPEG4 codec selected, there are cases where no image/audio is recorded for the  
first 5 seconds. (V11:423)  
When you reboot AXIS camera and have recording or action schedules which  
uses AXIS camera input pin for event trigger, there are some cases where these  
schedules doesn’t work correctly. To enable the schedules, be sure to deselect  
the [Enable] checkbox and apply in that camera’s [Sensor In] tab, and then  
select the [enable] check box again and apply. (VT1:2203)  
---Schedule Configuration  
The problem that occurs when configuring the event/alarm actions  
If you change the tour setting in the device menu while the Preset/Tour on  
[Camera Action] tab is already made, the value of [Action end preset] that was  
- 36 -  
   
NSR-1000 Series v1.1.1 Release Note  
configured before may disappear on [Camera Action] tab.  
After the tour settings are updated in the device menu, be sure to reconfigure  
[Action end preset]. (V11N:54)  
The problem that occurs when configuring the event/alarm actions  
If you change target devices for the action on the right side of the screen after  
some conditions for event/alarm actions are changed in [Schedule] screen, the  
values for the alarm condition are cleared. To work around this, do not change  
the target devices before the alarm condition setting. (V11N:73)  
---Media File Player  
When the image files with audio are converted into the AVI files using the  
Media File Player of v1.2.1.5, under the conditions mentioned below, the AVI  
files without audio are created.(V11R:9)  
When converting the recorded file which consists of image files (CAM files)  
and audio files (AUD files), and the AVI files are created from the CAM file  
straddling the second (or later) AUD file and the adjacent one, the latter AUD  
file fails in conversion of audio.  
Without With  
audio audio  
With audio  
- 37 -  
NSR-1000 Series v1.1.1 Release Note  
--Resolved limitations in V1.0.4  
---Installation / System Configuration  
When saving the system configuration information in Control Menu, the  
prohibited characters such as ,,can be used in the file name. However,  
you should not use those characters, because it is not possible to save it when  
using them. (VT1:1413)  
---Server Configuration  
The problem that the confirming dialog is shown when monitoring window is  
displayed or it logoff, if “Apply” button is not pushed, “Close” button is pushed  
and the setting changes are not saved in [E-mail] tab at Server setting window.  
(VT1:2022)  
The network information on the server setting screen cannot be displayed when  
used in German. (VT1:2242)  
---Main Window: Monitoring  
When double clicking a monitor frame during playing back with audio in Main  
GUI (1x1 mode), there might be an occasion that audio playback stops.  
(VT1:1096)  
When using the IP Desktop USB controller from CH Products, GUI may freeze  
or terminates abnormally by pushing the Preset button on the IP Desktop USB  
controller with the camera which does not support preset function.  
(VT1:2054)  
The image might flicker when the resolution is relatively high in the JPEG  
image. In this case, it flickers even if the images are recorded and played.  
(VT1:2182)  
In the case of alarm recording of VMD(Camera) at SNT-V704, red frame should  
be displayed, but it will be done on the screen at all channels of SNT-V704.  
(VT1:2187)  
- 38 -  
 
NSR-1000 Series v1.1.1 Release Note  
GUI abends at login when logoff while the alarm history panel is folded at main  
monitoring window. (VT1:2188)  
Play back audio is not available under the following conditions. (VT1:1906)  
The layout is changed to 1x1 with the monitor frame double-clicked during  
playing back. Please click ‘PLAYBACK’ button to restart after clicking  
‘LIVE’ button once.  
If user clicks ‘LIVE’ button during playing back at 1x1 layout, the  
NSR-1000 Series cannot make a sound. Please start to monitor live image  
except 1x1 and change layout to 1x1.  
The problem that video and audio are momentarily interrupted just when the  
layout of monitor frame is switched to 1x1 view by double-clicking on the  
monitor frame. (VT1:2085, VT2:737)  
The problem that camera video loss intermittently occurs when the live images  
are monitored with an AXIS camera of which codec is MPEG-4 at 1 fps.  
(VT1:2225)  
---Device Configuration  
When the video-related settings (Image size, Image Quality for JPEG, Bitrate  
for MPEG and Frame rate) differ between “Monitoring” and “Schedule  
recording”/“Event/alarm recording”  
on the [Video] tab of the Device  
Configuration screen, the settings under “Monitoring” are enabled for recording.  
(VT1:2046,2101)  
When canceling the VMD(Camera) setting, the previous setting is not saved  
properly and the Main GUI might be closed down without expectation. When  
VMD(Camera) is set, it is recommended to save the setting once without  
canceling and change it again. (VT1:1564)  
When creating and saving the name of a Camera Preset in configuration  
- 39 -  
NSR-1000 Series v1.1.1 Release Note  
window, a space can not be used in the Preset name. (VT1:1960)  
When VMD(Camera) is configured to SNT-V704, the detection area is created  
as QVGA size even though the detection area is configured as the full screen of  
the monitor frame. (VT1:2032)  
When the multiple cameras are selected in Device configuration, all the sensor  
input/output pins of the selected cameras are shown instead of the common  
sensor input/output pins among the selected cameras. (VT1:2089)  
In case of JPEG codec, the Monitoring Framerate might be the same value as  
the Recoding Framerate even though the Monitoring Framerate is more than  
the Recording Framerate. (VT1:2183)  
Only “All” can be selected by the selection of the network on the easy  
registration setting screen when used in German. (VT1:2241)  
On the [Video] tab of AXIS camera and encoder, if user changes one of the three  
configurations (Schedule Record, Alarm/Event Record, Monitoring) of codec,  
other two configurations of codec are not automatically changed. When these  
settings of codec are not the same, the codec of "Monitoring" is used for  
recording. (VT1:1917)  
Note that some cameras do not support the camera direct panning/tilting  
function and area zoom function. If you use the encoder together with the  
cameras, check the manual to see if the cameras to be used support the above  
functions. (VT1:2013)  
---Layout Configuration  
GUI may abend in case that user adds a layout without pushing "Apply" in the  
layout tour and after that user push "Apply" button with changing the sequence  
of layouts in the tour. (VT1:2245)  
- 40 -  
NSR-1000 Series v1.1.1 Release Note  
---Action Configuration  
When the schedule action is set, the camera preset setting might not be  
correctly preserved. (VT1:2177)  
---Search Window  
During the playback for the multiple cameras in the timeline view, the  
synchronization among the multiple cameras takes time when moving the slide  
bar. (VT1:2086)  
After object searching, the image on preview window is not refreshed to the  
search result time however you click and select a record from the search result  
list. Please check the time of record in the list and move to the point with  
timeline view. (VT1:2035)  
---Schedule Configuration  
In case of Alarm or Event recording by VMD (Recorder), a configuration name  
of the VMD (Recorder) should be the same if two or more triggers from different  
cameras with “Record by selected event” type are used for the recording  
schedule configuration. (VT1:2013)  
The problem that the reconfigured action is executed a day earlier when the  
schedule action is configured by specifying the days. (VT1:2209)  
---Export  
The problem that the export sometimes results in failure when executed from  
the object search window. (VT1:2047)  
The problem that the USB device is not ready until NSR is rebooted when  
exporting is cancelled and USB device is disconnected. (VT1:2224)  
- 41 -  
NSR-1000 Series v1.1.1 Release Note  
--Resolved limitations in V1.0.1  
There was a possibility that some recording frames were lost if the NSR-1000  
Series with the NSRE-S200 was carried out over long periods with overwriting.  
(VT1:1585)  
NSR-1000 Series could not display correct time on the monitor when below  
time zones were selected.  
GMT -0,-1,-3,-9,+9:30,+12 (VT1:1953)  
The Media File Player could not convert Megapixel images to AVI format when  
these images were exported with it. (VT3:744)  
Schedule action ran only once if the system alerts caused by hardware error  
were happen several times. (VT1:1945)  
The NSR-1000 Series could not export recording data to USB memory if the  
camera name was entered by two-byte character. (VT1:1936)  
Automatic Record configuration does not work correctly after device setting  
function modified. (VT1:1972)  
When user exported the recorded data to USB or DVD at the timeline result,  
user had to export it selecting the timeline. The NSR-1000 Series at this  
version can export the recorded data between mark-in and mark-out and the  
camera to be displayed. (VT1:1966)  
- 42 -  
 

VocoPro Car Stereo System CDG 4000 User Manual
Transition Networks SSDTF1011 100 User Manual
Sony HVL F56AM User Manual
Sony Handycam DCR HC54E User Manual
Sekonic L 408 User Manual
Sanyo Xacti VPC CG102 User Manual
Samsung HMX U100EN User Manual
Samsung BD E5200 User Manual
Rosewill R500N User Manual
Rola Bicycle Accessories 59403 User Manual