NOTICE  
The manufacturer of the POS cash drawer makes no representation or warranties, either  
expressed or implied, by or with respect to anything in this manual, and shall not be liable  
for any implied warranties of fitness for a particular purpose or for any indirect, special or  
consequential damages. Information in this document is subject to change without notice  
and does not represent a commitment on the part of the manufacturer.  
FCC NOTICE  
This equipment generates, uses, and can radiate radio frequency energy and if not installed  
and used in accordance with the instructions manual, may cause interference to radio  
communications. It has been tested and found to comply with the limits for a Class A digital  
device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide  
reasonable protection against interference when operated in a commercial environment.  
Operation of this equipment in a residential area is likely to cause interference in which case  
the user at his own expense will be required to take whatever measures may be required to  
correct the interference.  
1
P/N: 19240901021  
b). For CR4001/ 4101/ 4211/ 4002/ 4102/ 4212: CCBLA-196A with one 9PM and one  
9PF connector.  
c). For CR4003/ 4103/ 4213: CCBLA-089-1 with one 25PM and one 25PF connector.  
d). For CR4004/ 4104/ 4214: The serial signal cable is already built on.  
e). For CR4005/ 4105/ 4215/ CR4005-II/ 4105-II/ 4215-II: USB cable is already built on.  
6. Power Source depend on model  
a). For CR-4000/ 4100/ 4210: not applicable  
b). For CR-4001/ 4101/ 4211/ 4002/ 4102/ 4212/ 4003/ 4103/ 4213/ 4005/ 4105/ 4215 /  
CR4005-II / 4105 -II/ 4215-II: Power adapter 12VAC 1.5A  
c). For CR4004/ 4104/ 4214:Power connector cable and I/O bracket plate.  
INSTALLATION  
CR4000 / 4100 / 4210  
Connect the drawer to POS system/printer as shown below:  
Rear View  
8P Telephone Plug  
POS System or Printer  
Output to drawer  
Control signal input  
Ground  
CASH DRAWER  
8P Telephone Jack  
With Printer Interface  
6P Telephone Plug  
CR4001 / 4101 / 4211  
1).Connect the drawer serial I/P port to the computer COM port. Connect the power  
adapter output to the Power Input jack  
2).No other RS232C devices should be connected to the serial O/P port.  
3).Set position 3 of S2 to OFF and position 4 of S2 to ON. Please refer to rear panel  
illustration.  
CR4002 / 4102 / 4212  
1).Connect the drawer serial I/P port to the computer COM port. Connect the power  
adapter output to the Power Input jack.  
2).Other RS232C device can be connected to the serial O/P port when needed as long as  
the security code makes no influence to this RS232C device.  
3).Set position 3 of S2 to ON and position 4 of S2 to OFF. Set S1 for security code to open  
cash drawer. In normal practice, the security code is suggested to be a non-displayable  
ASCII character, for example, a hexadecimal number between 01 to 1F. Please refer to  
rear panel illustration below.  
CR4003 / 4103 / 4213  
1).Connect the drawer parallel I/P port to the computer LPT port. Connect the power  
adapter output to the Power Input jack.  
2).Other parallel device such as a printer can be connected to the parallel O/P port when  
needed as long as the Security code makes no influence to this parallel device.  
3
3).Set S1 for security code to open cash drawer. In normal practice, the security code is  
suggested to be a non-displayable ASCII character. For. example, a hexadecimal  
number between 01 to 1F. Please refer to rear panel illustration below.  
CR4001/ 4101/ 4211/ 4002/ 4102/ 4212/ 4003/ 4103/ 4213 Rear panel illustration.  
AC 12V I/P  
PARALLEL O/P (DB25F)  
Switch is ON when pushed up  
SERIAL O/P (DB9M)  
S1  
S2  
8
1 4 1  
SERIAL I/P (DB9F)  
PARALLEL I/P (DB25M)  
GROUND  
S1  
Set security code. (Default Setting: BIT 1,2,3 OFF and BIT 4,5,6,7,8 ON. Security  
code is 07H)  
BIT  
1
1
2
2
3
4
4
8
5
6
7
8
Number to be added to the  
security code if OFF.  
16  
32  
64 128  
S2 BIT1 ON and BIT2 OFF to receive security code via Pin2 of P4 (DB9F).  
BIT1 OFF and BIT2 ON* to receive security code via Pin3 of P4 (DB9F).  
BIT3 OFF and BIT4 ON for dedicated RS-232C.  
BIT3 ON and BIT4 OFF* for non-dedicated RS-232C.  
(*denotes factory default setting)  
616P PHONE JACK  
CR4004 / 4104 / 4214  
1). Open the PC case. Put the metal  
bracket with power connector into one  
of the I/O windows.  
2). Connect the cable to the HDD type  
power connector of PC power supply.  
See illustration below. Then close the  
PC case.  
3). Connect the DB-9 connector to the  
computer's serial port of COM1 (or  
POWER CORD  
COM2). Connect the 4P phone plug connector to the added I/O bracket. See below  
illustration.  
4
COM1  
616P PHONE JACK  
DB9  
4PIN PHONE JACK  
CR4005/ 4105/ 4215/ CR4005-II/ 4105-II/ 4215-II  
1). Define a drawer number for the cash drawer so that this cash drawer is going to respond  
accordingly in USB communication. Follow the table below for SWITCH SETTING to  
adjust the switch S1 according to this drawer number if it is not 7. Please note that  
within each system there should never be any 2 USB interface cash drawers carrying the  
same drawer number.  
O
4
3 2  
1
N
Connect to USB  
Port of Main PC  
S1  
AC 12V I/P  
Power Jack of CR4005/4105/4215/  
CR4005-II/ 4105-II/ 4215-II  
USB Connector from CR4005/4105/  
4215/CR4005-II/ 4105-II/ 4215-II  
Rear View of Model CR4005/4105/ 4215/CR4005-II/ 4105-II/ 4215-II Cash  
Drawer with USB Interface  
SWITCH SETTING:  
0
1
2
3
4
5
6
7
Drawer  
SW1  
ON OFF ON OFF  
ON OFF ON OFF  
ON ON OFF OFF  
ON  
ON  
ON OFF OFF  
SW2  
ON  
ON  
ON OFF OFF OFF OFF  
SW3  
Reserved  
SW4  
Default setting: Drawer 7 (SW1: OFF; SW2: OFF; SW3: OFF)  
2). Connect USB connector of cable coming out from the rear side of the USB interface  
cash drawer to USB port of main PC.  
3). Check the specification of power adaptor on its nameplate. Insert the power adaptor into  
the correct power outlet. Insert the output plug to the jack at rear side of CR4005/ 4105/  
4215/ CR4005-II/ 4105-II/ 4215-II to supply power for drawer kickout.  
4). Install the USB utility driver from Posiflex Product Information CD with Posiflex POS  
5
UPOS driver application (Applied for all Posiflex cash drawer)  
Please first find in Posiflex Product Information CDROM or download from Posiflex  
web sites for UPOS driver setup. In this application CR4XX3 and CR4XX4 respond to  
openDrawer command only; CR4XX0, CR4XX1 and CR4XX2 are compliant to UPOS  
version 1.4; CR4XX5 are compliant to UPOS version 1.7 and CR4XX5-II are compliant to  
UPOS version 1.8.  
FUNCTIONAL TEST  
CR4000 / 4100 / 4210  
1.Follow the printer’ s manual of the printer the cash drawer is connected to open cash drawer.  
2.If the cash drawer is connected to a Posiflex POS system, follow the technical instruction of  
the system to open the cash drawer.  
CR-4001 / 4101 / 4211 / 4002 / 4102 / 4212 / 4004 / 4104 / 4214  
1.Under DOS prompt, type “MODE COM1 96 N 8 1”. Hit the ENTER key.  
2.Type “TYPE CON>COM1”. Hit the ENTER key.  
3.Type “CTRL-G” (Press Ctrl and G keys together). Hit the ENTER key, then the drawer  
will open.  
4.Hit CTRL-C (Press Ctrl and C keys together) to return the computer back to the normal  
display mode.  
In case the cash drawer is connected to serial port other than COM1 please substitute COM1  
above to proper port name.  
If the pre-set security code of CR-4002/ 4102/ 4212 has been changed from default 07 Hex.  
Please change the CTRL-G above accordingly. For CR4001/ 4101/ 4211/ 4004/ 4104/ 4214,  
this code can be replaced by any character.  
CR-4003 / 4103 / 4213  
1.Under DOS prompt, type “TYPE CON>LPT1”. Hit the ENTER key.  
2.Type “CTRL-G” (Press Ctrl and G keys together). Hit the ENTER key, then the drawer  
will open.  
3.Hit CTRL-C (Press Ctrl and C keys together) to return the computer back to the normal  
display mode.  
If the pre-set security code of CR-4003/ 4103/ 4213 has been changed from default 07 Hex.  
Please change the CTRL-G above accordingly.  
CR4005/ 4105/ 4215/ CR4005-II/ 4105-II/ 4215-II  
1.Please find in Posiflex Product Information CDROM or go to Posiflex web sites (http:  
Drawer Test Program. If you use the Posiflex Product Information CDROM that comes  
with any Posiflex POS system, please go to folder “\Drivers\CR\USB” and click  
“SETUP.EXE” to install the USB Cash Drawer Test Program.  
6
2.Start up the test program and click “STATUS” button. The drawer status of Open/Close or  
Not present will be displayed under each drawer number as “O”, “C” or “N”  
3.Use a key to turn the lock to standby position (the one marked with sign at middle), click  
the check only the box (es) under the drawer number(s) for the drawer(s) to be tested then  
click the “KICK” button.  
4.The cash drawer will then open and the Open/Close/Not present status of the tested drawer  
number will be renewed accordingly. If these status are correct, the USB interface cash  
drawer passes the test.  
SPECIFICATIONS  
MECHANICAL: Dimensions: 428 (W) x 460 (D) x 100 (H) mm  
Weight:  
6.0 Kgs  
Removable tray with a lock-on cover (option)  
ELECTRICAL:  
Power Source  
Solenoid Drive (for CR-4000 / 4100 / 4210)  
Pulse Amplitude  
12 to 24 VDC  
Pulse Width  
100 to 250 msec  
Pulse Duty Cycle  
Max. Current Consumption  
10% max.  
0.75A @ 12 VDC/1.5A @ 24 VDC  
AC Adaptor (for CR-4001/ 4101/ 4211/ 4002/ 4102/ 4212/ 4003/ 4103/ 4213/ 4005/ 4105/  
4215/ 4005-II/ 4105-II/ 4215-II)  
Input Voltage  
Output Voltage  
120 VAC ± 10 % / 240 VAC ± 10 % @50 -60 Hz  
12 VAC at 1.5 A  
DC Power Kit (for CR-4004 / 4104 / 4214): +12 V DC and + 5 V DC  
Interface  
Direct Drive: CR4000/ 4100/ 4210  
Serial (RS232C)  
CR-4001  
CR-4101  
CR-4211  
9600  
None  
8
CR-4002  
CR-4102  
CR-4212  
9600  
none  
8
CR-4004  
CR-4104  
CR-4214  
150 ~ 19200  
none, even, or odd  
7 or 8  
Baud rate  
Parity  
Data Bits  
Stop Bits  
1 or 2  
1 or 2  
1 or 2  
Parallel (IEEE1284): CR-4003/ 4103/ 4213  
USB (1.1): CR-4005/ 4105/ 4215/ 4005-II/ 4105-II/ 4215-II  
7
Security Code  
CR-4002/ 4102/ 4212/ 4003/ 4103/ 4213  
CR-4005/ 4105/ 4215/ 4005-II/ 4105-II/ 4215-II  
1-255; factory preset value = 7  
USB PID  
Drawer Open Sense  
CR-4000/ 4100/ 4210  
CR-4001/ 4101/ 4211/ 4002/ 4102/ 4212  
Drawer open sense circuit shorts when open  
Pin 9 shorts to pin 5 when drawer open  
CR-4005/4105/4215/4005-II/4105-II/4215-II Through USB driver  
KEYLOCK OPERATION  
Physically lock the drawer.  
Open the drawer by the key.  
Automatically open the drawer by POS printer  
or POS system or interface signal control  
STRUCTURE  
Check Slot  
Inside CR-4000/ 4001/ 4002/ 4003/ 4004/ 4005/ 4005-II/ 4100/ 4101/ 4102/ 4103/ 4104/  
4105/ 4105-II  
Bill compartment  
Bill Clip  
Coin compartment  
Cash Tray  
Coin Roll Storage  
Tray for CR-4210/ 4211/ 4212/ 4213/ 4214/ 4215/ 4215-II  
Bill compartment  
Coin Roll Storage  
Cash Tray  
Bill Weight  
Coin compartment  
8

Rinnai Q205SP User Manual
PYLE Audio PLRD195IF User Manual
Planar Systems Car Video System LC SERIES User Manual
Philips SHB7110 User Manual
Philips AVCHD HDC TM20 User Manual
Morphy Richards FP48952MEE User Manual
Lennox International Inc Boiler GWB8 299E 2 User Manual
Kenwood KVT 627DVD User Manual
K2 Bike K013906 User Manual
JVC KDS23 User Manual