Lincoln REDCO INSTABLEND 16900 User Manual

INSTALLATION & OPERATING  
INSTRUCTIONS  
for  
REDCO® INSTABLEND™  
MODEL 16900 SERIES  
TO BE SERVICED ONLY BY AUTHORIZED PERSONS  
Instablendopsman  
REV: 4/10/07  
Part Number: 2810255  
MODELS  
This manual describes the operation and maintenance of the 16900, 16901, 16902, 16903 and 16904 portable  
liquidizers, mixers and liquidizer/mixers.  
The model reference and its specifications are shown on the identification plate located on the front of the unit.  
The InstaBlend has been designed and manufactured in accordance with the following standards:  
Standards for machine safety: UL 1097, UL 763, UL 94  
Standards for Hygiene and Food equipment materials: ANSI-NSF 8 and ANSI-NSF 51.  
UTILITY SPECIFICATION  
REDCO® INSTABLEND™  
Specifications  
Liquidizer Arm Length  
Mixer Arm Length  
Total Length  
16900  
15”  
-
16901  
21”  
-
16902  
15”  
16903  
-
16904  
10.5”  
-
15.5”  
27.5”  
15.5”  
28”  
29”  
35”  
21.5”  
Electrical Supply  
Constant Speed (RPM)  
Range (RPM)  
120V / 50Hz / 60Hz / 1 Phase  
14000  
15000  
14500  
14500  
4.2 lbs.  
1000-11000  
7.4 / 7.7 lbs.  
1000-11000  
7.7 lbs.  
Weight  
7.4 lbs.  
9.1 lbs.  
INSTALLATION  
For best results and a long service life, follow the instructions given in this manual.  
POSITIONING  
The InstaBlend is not permanently fixed in one location. It can be carried to the required location/area for use  
where there is a suitable wall receptacle. Each unit is supplied with a wall for convenient storage.  
InstaBlend - 16000 Series Ops Manual  
3
OPERATION  
Plug the appliance into a proper electrical outlet.  
MODELS 16900, 16901, 16902, 16903  
STARTING  
Pressing the “Start” button (B) together with the  
“Safety” button (D) will cause the machine to  
start. The machine will not start if the “Safety”  
button is not actuated. Releasing the “Start”  
button will cause the machine to stop operating.  
CONTINUOUS OPERATION  
For continuous operation, while the machine is  
running, press the “Lock” button (C). After the  
“Lock” button is depressed, the “Start” button  
may be released and the machine will continue to  
operate. Pressing the “Start” button again will  
shut off the machine.  
Models 16902 and 16903 – The Speed Control  
(A) may be adjusted to change the speed of the  
blade or mixer.  
MODEL 16904  
STARTING  
Pressing the “Start” button (1) together with the  
“Safety” button (2) will cause the machine to  
start. The machine will not start if the “Safety”  
button is not actuated. After the machine has  
started, the “Safety” button may be released and  
the machine will continue to operate. Releasing  
the “Start” button will cause the machine to shut  
off.  
BEST RESULTS  
Best results are achieved by introducing the arm of the machine into the bowl, up to 2/3 of the arm’s length.  
For optimum operation, it is better if the foot of the machine does not touch the bottom of the bowl.  
In order to prevent splashed food from getting inside the motor unit, it is recommended not to incline the appliance  
more than 30°.  
4
InstaBlend - 16000 Series Ops Manual  
MAINTENANCE  
WARNING  
!
!
TO AVOID ELECTRICAL SHOCK THAT CAN CAUSE SEVERE INJURY OR DEATH, ALWAYS UNPLUG  
LIQUIDIZER / MIXER BEFORE PROCEEDING WITH ANY CLEANING OR MAINTENANCE PROCEDURES!  
IN ORDER TO AVOID DAMAGE TO PEOPLE AND THE APPLIANCE, READ AND FOLLOW THE  
MANUFACTURER’S INSTRUCTIONS FOR THE CLEANING OF THE LIQUIDIZER / MIXER.  
DO NOT USE THE FOLLOWING PRODUCTS:  
• Abrasive cleaners such as Ammonia, Lye, etc.  
• Solvents  
• Metal Scourers  
• Gritty Detergents  
These products would score, scratch and damage the metallic and plastic surfaces of the appliance.  
CLEANING PROCEDURE  
All parts of the machine that come into contact with the food product should be cleaned immediately after each use.  
Place up to 2/3 of the length of the mixer arm into hot water (95°F to 115°F) and switch on for a few seconds. The  
mixer and blade must be cleaned with hot water and a mild detergent, leaving the blade with warm water to remove  
any residue. Allow the mixer arm and blade to air dry.  
The motor set must be cleaned with a damp cloth. Under no circumstances must water enter the motor set. If  
water accidentally enters the motor set, dry the motor set carefully before switching on the machine.  
After cleaning, place the machine in its wall support.  
Models 16900, 16901, 16902, 16903:  
The Liquidizer/Mixer arm may be removed for cleaning. To remove the Liquidizer/Mixer arm, turn the  
Liquidizer/Mixer clockwise until the arm separates from the motor set. To reassemble, reverse the procedure.  
InstaBlend - 16000 Series Ops Manual  
5
ADDITIONAL INFORMATION  
In the event the power supply cord becomes damaged and has to be replaced, the repair  
may only be completed by a Lincoln Authorized Service Agency. Information on Authorized  
Service Agencies maybe obtained by calling Lincoln Technical Support at (800) 678-9511.  
DO NOT USE THE MACHINE IF THE POWER SUPPLY CORD IS DAMAGED.  
WARNING:  
!
In order to prevent injury or damage to the InstaBlend, never put utensils or hands into the  
mixture.  
WARNING:  
WARNING:  
!
!
The blade edges are sharp and care should be exercised when cleaning.  
The airborne noise emitted by the appliance, as measured on a type appliance at a distance of one (1) meter is  
less than 80dB(A).  
WARNING – SHOCK HAZARD: To reduce the risk of injury or death by electric shock:  
!
1. Do not place or store where Liquidizer/Mixer can fall or be knocked into water or other liquid mixture.  
2. If Liquidizer/Mixer falls into water or other liquid mixture, unplug immediately.  
Do not reach into water or liquid mixture to retrieve.  
3. Do not allow water or other liquid mixture to enter the motor housing slots when using or cleaning.  
4. Switch power “OFF” and disconnect from power source before cleaning and when not in use.  
WARNING – SHARP OBJECTS: Machine uses sharp, rapidly moving mixing blades.  
To reduce the risk of injury:  
!
1. Immerse mixing blades before turning on the Liquidizer/Mixer.  
2. Turn “OFF” Liquidizer/Mixer before removing blades from mixture.  
3. Avoid contact with moving blades.  
6
InstaBlend - 16000 Series Ops Manual  
This page intentionally left blank.  
InstaBlend - 16000 Series Ops Manual  
7
PARTS LIST  
MODELS 16900, 16901, 16902, 16903  
Number  
1A  
1B  
2
Description  
Variable Speed Control  
Speed Control  
Hood Set  
Spare Part #  
380067  
380066  
380069  
380071  
380077  
370075  
380057  
380079  
380060  
380070  
380064  
380074  
380072  
380073  
380055  
380058  
380061  
380054  
380080  
380056  
380062  
380059  
380063  
380068  
380065  
380076  
380078  
16900  
16901  
16902  
16903  
3A  
3B  
4
Motor Frame Set  
Motor Frame Set  
Reducing Frame Set  
Blade Lower Locking Set  
Whisks Shaft Set  
Brush Set  
5
6
7A  
7B  
8
Brush Set  
Control Protectors Set  
Motor Set  
9A  
9B  
9C  
10  
Motor Set  
Motor Set  
Bearings – Grommet Set  
Blade Set  
11A  
11B  
12  
Blade Set  
Arm Coupling Nut Set  
Whisks Set  
13  
14A  
14B  
15A  
15B  
16  
Arm Shaft  
Arm Shaft  
Turbine Protector  
Turbine Protector  
Power Cord  
17  
Coupling Set  
18  
Reducer Shaft  
Wall Support  
19  
Turbine Lock Key  
(blade removal tool)  
20  
21  
380084  
Liquid Arm Assembly – 21”  
Liquid Arm Assembly – 15”  
380081  
380082  
380083  
Not Shown Mixer Arm Assembly  
8
InstaBlend - 16000 Series Ops Manual  
PARTS DIAGRAM  
MODELS 16900, 16901, 16902, 16903  
InstaBlend - 16000 Series Ops Manual  
9
PARTS LIST  
MODEL 16904  
Number  
Description  
Wall Support Set  
Spare Part #  
380052  
380050  
380041  
380042  
380040  
380045  
380047  
380053  
380043  
380048  
380049  
380046  
380044  
380051  
16904  
1
2
Switch, 2-Pole  
Blade Set  
3
4
Coupling Set  
5
Lower Hood Set  
Bearings-Grommets Set  
Motor Set  
6
7
8
Power Cord  
9
Frames Set  
10  
11  
12  
13  
14  
Protectors and Screws Set  
Shaft  
Brush Set  
Grinder Arm Set  
Turbine Protector  
10  
InstaBlend - 16000 Series Ops Manual  
PARTS DIAGRAM  
MODELS 16904  
InstaBlend - 16000 Series Ops Manual  
11  
SCHEMATIC DIAGRAMS  
MODELS 16000, 16901  
12  
InstaBlend - 16000 Series Ops Manual  
SCHEMATIC DIAGRAMS (CONT’D)  
MODELS 16902, 16903  
InstaBlend - 16000 Series Ops Manual  
13  
SCHEMATIC DIAGRAMS (CONT’D)  
MODEL 16904  
14  
InstaBlend - 16000 Series Ops Manual  
This page intentionally left blank.  
InstaBlend - 16000 Series Ops Manual  
15  
Lincoln Foodservice Product, LLC  
1111 North Hadley Road  
Fort Wayne, Indiana 46804  
United States of America  
Telephone: (260) 459-8200  
U.S. Fax: (888) 790-8193  
Int’l Fax: (260) 436-0735  
Technical Support Hotline: (800) 678-9511  

Planar Systems Car Video System PL160M User Manual
Phoenix Gold Car Amplifier TI2 10004 User Manual
Phoenix Gold Car Amplifier R2501 User Manual
Panasonic Stereo System SC PMX9DB User Manual
Nikon Camcorder D70 User Manual
Newcon Optik NVS 7 4X User Manual
Kenwood KRC 579B User Manual
Kenwood KDC MP825 User Manual
Kenwood FFINELINE RFU 6100 User Manual
JVC KD APD89 User Manual