PHOTO TACH OPERATION
Measurement Procedure:
BATTERY REPLACEMENT
Measurement Procedure:
1. Unscrew contact collar from optical end of
505 (if attached).
1. Remove the screw holding the battery compart-
ment cover in place on the back of the 505.
2. Slide the cover off of the unit.
3. Remove the 2 each “AA” alkaline batteries and
replace with the same type.
2. Attach a piece of reflectIive tape on the rotating
object to be measured.
3. Depress and hold the START button and then
press the Photo button (lower right) on the
505.
4. Replace the cover and screw.
4. With the start button depressed, point the
optical end at the rotating surface so the
relective tape passes the lens every rotation.
5. Read the RPM on the LCD display.
STANDARD ACCESSORIES
Memory Recall
Reflective Tape . . . . . . . . . . . . . . . . . . . . . . .A501
Contact RPM Adapter (screw on) . . . . . . . . .A502
RPM Adapter (Cone Type) . . . . . . . . . . . . . .A503
RPM Adapter (Funnel Type) . . . . . . . . . . . . .A504
Surface Speed Test Wheel . . . . . . . . . . . . . .A505
(O.D. 48.7 mm exactly)
Note: The memory resets itself once the START
button is depressed and stable measurements
are displayed for 10 seconds or 12 revolutions
(whichever is longer). The values are stored
when the START button is released.
Carrying case . . . . . . . . . . . . . . . . . . . . . . . .A915
1. When you are finished taking measurements,
release the START button.
2. Depress the MEMORY button once, the LAST
reading will be displayed
3. Press the MEMORY button twice, the MAX
reading will be displayed.
4. Press the MEMORY button three times, the MIN
reading will be displayed.
Unit will auto power off after 5 seconds.
6
3
SURFACE SPEED OPERATION
Measurement Procedure:
CONTACT TACH OPERATION
Measurement Procedure:
1. Screw the shaft assembly to the optical end of
the 505.
1. Screw the shaft assembly to the optical end of
the 505.
2. Insert the cone or concave wheel that more
closely matches the end of the component to
be measured on the shaft assembly.
3. Press and hold the START button and then
press the Contact button (lower left) on the
505.
4. While pressing the START button, hold the
wheel against the end of the rotating shaft..
5. Read the RPM on the LCD.
2. Insert the large wheel to the end of the shaft
assembly.
3. Press and hold the START button and then
press the ft/min (feet per minute) or m/min
(meters per minute) on the 505.
4. While pressing the START button, hold the
wheel against the moving surface.
5. Read the speed on the LCD.
Memory Recall
Memory Recall
Note: The memory resets itself once the START
button is depressed and stable measurements
are displayed for 10 seconds or 12 revolutions
(whichever is longer). The values are stored
when the START button is released.
Note: The memory resets itself once the START
button is depressed and stable measurements
are displayed for 10 seconds or 12 revolutions
(whichever is longer). The values are stored
when the START button is released.
1. When you are finished taking measurements,
release the START button.
2. Depress the MEMORY button once, the LAST
reading will be displayed
3. Press the MEMORY button twice, the MAX
reading will be displayed.
4. Press the MEMORY button three times, the MIN
reading will be displayed.
1. When you are finished taking measurements,
release the START button.
2. Depress the MEMORY button once, the LAST
reading will be displayed
3. Press the MEMORY button twice, the MAX
reading will be displayed.
4. Press the MEMORY button three times, the MIN
reading will be displayed.
Unit will power off after 5 seconds.
Unit will power off after 5 seconds.