GENERAL DATA  
(AT 230V)  
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)  
POWER V/PH/HZ  
Circuit Ampacity, Min. (A)  
Fuse size, Max.  
230/208/1/60  
35  
35  
COOLING  
Total Capacity  
Sensible Capacity  
Latent Capacity  
SEER  
Dehumidification  
Amps  
(BTU/H)  
(BTU/H)  
(BTU/H)  
34,800/33,000  
22,320/21,700  
11,680/11,300  
10.6/10.9  
(A)  
COMPRESSOR  
No. used  
R.L. Amps - L.R. Amps (A)  
Crankcase Heater  
Rotary-Hermetic  
1
12.5 ñ 95.0  
30W  
(Pints/H)  
(A)  
10.6/10.8  
15.0/15.5  
Power Inputs  
(W)  
3,340/3,130  
7.9  
OUTDOOR FAN - TYPE  
Dia. (in.) - No. used  
Type Drive - No. speeds  
No. Poles - RPM (High)  
No. Motors ñ HP  
Propeller  
18-3/32 - 2  
Direct ñ 3 (AUTO)  
6 - 879  
Outdoor Sound Rating (bels)  
FEATURE  
2 - 110  
CFM (High)  
F.L. Amps.  
3,670  
1.8  
Controls  
Microprocessor  
LCD Wireless type  
IC Thermostat  
ON/OFF, 24 hours  
Built-In  
Manual  
Automatic  
Built-In  
N/A  
(A)  
Remote Controller  
Temperature Control  
Timer  
Night-Setback  
Air Louver (Horizontal)  
(Vertical)  
OUTDOOR COIL - TYPE  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area (sq.ft.)  
Tube Size (in.)  
Aluminum Fin & Copper Pipe  
Slit Plate - Inner Riffled  
2 - 12.7  
11.63  
3/8  
Power Failure Automatic Restart  
Self Diagnosis  
INDOOR FAN - TYPE  
Dia. (in.) - No. used  
No. speeds  
No. Poles -RPM (High)  
No. Motors ñ HP  
CFM (HI/MED/LOW)  
F.L. Amps (A)  
Cross - Flow  
5-29/32 & 39-4  
3 & Auto  
4 - 1,015  
1 - 100  
OPTION  
Refrigerant Line Set  
AP3210BH (30 ft)  
AP3215BH (50 ft)  
900/790/680  
0.7  
INDOOR COIL ñ TYPE  
Fin Type - Pipe type  
Rows - F.P.I.  
Face Area (sq. ft.)  
Tube Size (in.)  
Aluminum Fin & Copper Pipe  
Slit Plate - Inner Riffled  
2 - 12.7  
3.51  
5/16  
Low Ambient Control  
Fresh Air Intake  
Available  
Available  
Available  
N/A  
N/A  
Available  
Available  
Central Remote ON-OFF Control  
Airduct Extension  
Indoor Frame Extension  
Condensate Drain Pump  
Non-Removable Remo-con Bracket  
Drain Connection Size (in.)  
1-1/4  
REFRIGERANT  
R22  
Lbs. - R22 (O.D. Unit)  
Control  
Connection  
Line Length, Max (ft.)  
Lift difference, Max (ft.)  
Line Size - in. O.D. Discharge  
Line Size - in. O.D. Suction  
9.48  
Capillary Tube  
Flare  
165  
100  
3/8  
OPERATING RANGE  
Cooling  
Indoor Air  
Intake Temp.  
95 F DB/71 F WB  
67 F DB/57 F WB  
Outdoor Air  
Intake Temp.  
115 F DB  
3/4  
Maximum  
Minimum  
67 F DB  
DIMENSIONS (in.)  
Indoor Unit -Uncrated 9-7/16 x 62  
-Crated 12 x 65-20/32 x 29-3/4  
Outdoor Unit -Uncrated 48-5/8 x 37  
-Crated 52ñ7/32 x 40  
H
x
W
x
D
x 26-3/8  
CERTIFICATION  
x 13-3/8  
x 16-12/32  
WEIGHT  
Net  
Shipping(lbs.)  
INDOOR  
84.0  
97.0  
OUTDOOR  
198.0  
223.0  
(lbs.)  
Shipping Volume (cu.ft.)13.6  
19.8  

Xerox 440 User Manual
NEC MULTISYNC P462 User Manual
Motorola Mbp8 User Manual
Mitsubishi Motors Automobile Parts 4d68 E W User Manual
MAKITA G6100R User Manual
Makita Dc18se User Manual
JVC CONNECTED CAM GY HC500U User Manual
GARLAND TECHNOLOGY PACKETMAX AA100G32AC 02 User Manual1
EMERSON LIEBERT GXT4 6000RTL630 User Manual
CRAFTSMAN 536.887752 User Manual