DELTA DVP FEN01 User Manual

繁體中文  
Control Registers  
注意事項  
DVP-FEN01 Ethernet communication card  
Register name  
Model name  
38  
本安裝說明書提供給使用者電氣規格、功能規格、安裝配線之相關注意事項。其他詳細關於 DVP-FEN01 所  
支援的協定內參閱 DVP-FEN01 操作手冊及相關專業手PLC 安裝環境及方式及注意事項請參考 PLC  
安裝手冊。  
CR number  
Attribute  
R
Description  
HW  
-
LW  
#0  
Read only; The model code of DVP-FEN01 = H’ 6151  
本機屬於 PLC 之通訊使用者使用本產品須將其安裝於 DVP-EH3 系列之主機(僅支援 DVP-EH3  
69  
It adopts the hexadecimal system, and the present  
firmware version is stored in it.  
-
#1  
R
-
Firmware version  
Reserved  
系列 32 點(含)以上主機,且韌體版本 V1.12 版(含)以上)。  
請在上電之前再次確認 PLC 主機電源配線,並請勿在上電時觸摸任何端子。  
請務必仔細閱讀本安裝說明,並依照本說明指示進行操作,以免造成產品受損,或導致人員受傷。  
#12~#2  
Users can set CR#13 to “sending the data” or “not  
sending the data”.  
-
#13  
R/W  
Enabling the data exchange  
Specifications  
Communication Interface  
功能特色  
#16~#14  
-
R/W  
-
Reserved  
Ethernet Interface  
-
-
#17  
Execution cycle of the data exchange (ms)  
1. 提供 DVP-EH3 系列 PLC 主機 Ethernet 通訊功能  
Connector  
RJ-45 with Auto MDI/MDIX  
#18  
Reserved  
2. 內建 Ethernet RS-232 通訊口  
Number of ports  
1 Port  
States of the slaves involved b[0:7] indicate the states of the slaves 1~8 involved in  
3. Ethernet 通訊口可自動偵測 10/100Mbps 傳輸速率  
-
#19  
R
-
Transmission cable Category 5e 100M (Max) / UC-PRG030-20A  
in the data exchange  
Reserved  
the data exchange  
4. 支援 Ethernet 協定:ARPIPTCPUDPDHCPMODBUS TCP  
5. MODBUS TCP Client 8 組(發送封包MODBUS TCP Server 4 組(接收封包)  
6. 支援 4 IP Filter 功能,過濾可存取的 IP 地址  
Baud rate  
10/100 Mbps Auto-Detect  
ARP, IP, TCP, UDP, DHCP, MODBUS TCP, Delta Configuration  
#86~#20  
Communication  
protocol  
0: Static IP  
-
#87  
R/W  
IP address setting mode  
IP address  
1: DHCP  
RS-232 Interface  
7. 支援 DVP-EH3 系列主機 COM3可透過 RS-232 Ethernet 通訊口支援上下載 PLC 程式與監控 PLC  
When the IP address is 192.168.1.5, the data in  
CR#89 is 192.168, and the data in CR#88 is 1.5.  
When the mask address is 255.255.255.0 the data in  
CR#91 is 255.255, and the data in CR#90 is 255.0.  
When the GIP address is 192.168.1.1, the data in  
CR#89 is 192.168, and the data in CR#88 is 1.1.  
0: The setting of the IP address is not executed.  
1: The setting of the IP address is executed.  
0: The setting is unfinished  
#89  
#91  
#93  
-
#88  
#90  
#92  
#94  
R/W  
R/W  
R/W  
R/W  
Connector  
Mini DIN  
1 Port  
Number of ports  
產品外觀尺寸與部位介紹  
Transmission cable UC-MS030-01A / UC-PRG020-12A  
Mask address  
Baud rate  
19,200bps  
螺絲固定孔  
Communication  
format  
3
1
4
Gateway IP address  
Data bit8  
Parity bitNone  
Stop bit1  
PLC 連接埠  
Communication  
protocol  
Enabling the IP address  
setting  
MODBUS ASCII  
RS-232 訊埠  
RJ-45 通訊埠  
Electrical Specifications  
5
Power voltage  
5VDC (supplied through the PLC connector)  
-
#95  
R
-
IP address setting status  
Reserved  
1: The setting is being executed.  
Power consumption 1W  
Activity 指示燈(橙色)  
Link 指示燈(綠色)  
通訊卡拆卸拉桿  
2: The setting is complete  
2
Weight  
16g  
6
7
8
#250~#96  
Environment  
bit 0: The network is unconnected.  
bit 3: CR#13 is set to “sending the data”, but the data  
exchange is not enabled.  
ESD (IEC 61131-2, IEC 61000-4-2): 8 kV Air Discharge  
Noise immunity  
EFT (IEC 61131-2, IEC 61000-4-4): Communication I/O: ±2 kV  
CS (IEC 61131-2, IEC 61000-4-6): 0.15 ~ 80 MHz, 3 Vrms  
-
#251  
R
Error status  
韌體燒錄開關  
(正面)  
(側面)  
(反面)  
bit 8: DHCP does not acquire the correct network  
parameter.  
(使用前請確認已切換至 OFF 端)  
Operation: 0°C ~ 55°C (temperature); 5 ~ 95% (humidity); pollution degree 2  
Storage: -25°C ~ 70°C (temperature); 5 ~ 95% (humidity)  
Operation/Storage  
#255~#252  
-
Reserved  
Vibration/Shock  
immunity  
International standards: IEC61131-2, IEC68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27  
(TEST Ea)  
Definitions: R represents that users can use the instruction FROM to read the data.  
W represents that users can use the instruction TO to write the data.  
Installation  
Combining DVP-FEN01 with the PLC  
Before installing or removing the communication card, you should turn off the PLC, and open the cover of the  
slot, as shown below.  
LED Indicators & Troubleshooting  
LED Indicators  
ENGLISH  
Warning  
This instruction sheet only provides information about electrical specifications, installation and wiring. With regard to  
the communication protocol supported by DVP-FEN01, please refer to DVP-FEN01 Operation Manual and other  
professional manuals. As to the installation environment for the PLC and the points for attention, please refer to PLC  
Installation Manual.  
38  
LED indicator  
LED indicator status  
ON  
Description  
The Ethernet connection succeeds.  
The Ethernet connection fails.  
Link LED indicator  
Green  
OFF  
1. Installing the communication card: Put the communication card vertically into the slot, and tighten the screw.  
Flashing  
Flashing  
The data is being sent/receive through the Ethernet.  
No data is sent through the Ethernet.  
The product is the communication card used with the PLC. When users use this product, they need to install it on the  
DVP-EH3 series PLC. (It only supports the DVP-EH3 series PLC with more than 32 I/O points (included 32) and  
with the firmware version above V1.12.)  
Activity LED indicator  
Orange  
69  
Troubleshooting  
Please check the wiring of the PLC before it is powered, and do not touch any terminal when it is powered.  
Problem  
Reason  
Solution  
Be sure to read the instruciton sheet carefully. In order to prevent the product from being damaged, or to prevent the  
operators from being hurt, please operate the product according to the instructions.  
Please check whether the PLC is powered, and  
whether the power is supplied to the PLC normally.  
The PLC is not powered.  
功能規格  
通訊介面  
DVP-FEN01 is not combined Please check whether DVP-FEN01 is properly  
Features  
Link LED indicator is off.  
with the PLC.  
combined with the PLC.  
2.  
Removing the communication card  
1. It provides the DVP-EH3 series PLC with the Ethernet communication function.  
2. The Ethernet communication port and the RS-232 communication port are built in it.  
3. The Ethernet communication port automatically detects the transmission speed of 10/100Mbps.  
4. It supports the Ethernet protocol (ARP, IP, TCP, UDP, DHCP, and MODBUS TCP).  
5. There are eight sets of MODBUS TCP clients, and four sets of MODBUS TCP servers.  
6. It supports four sets of IP filters which filtering the accessible IP address.  
Please check whether the Ethernet cable is correctly  
connected.  
The Ethernet connection fails.  
Ethernet 介面  
RJ-45 with Auto MDI/MDIX  
1 Port  
接頭  
埠數  
Category 5e 100M (Max) / UC-PRG030-20A  
10/100 Mbps Auto-Detect  
線材  
傳輸速率  
通訊協定  
RS-232 介面  
接頭  
7. It supports COM3 on the DVP-EH3 series PLC. The program in the PLC can be downloaded/uploaded  
and monitored through the RS-232 communication port and the Ethernet communication port.  
3.  
Making a check after the installation  
ARP, IP, TCP, UDP, DHCP, MODBUS TCP, Delta Configuration  
First, power the PLC, and connect the Ethernet cable with the RJ-45 connector on DVP-FEN01. When  
Link LED indicator (green) on DVP-FEN01 is continuously on, it means that the PLC is connected to  
DVP-FEN01 correctly and the power is supplied normally. Next, open DCISoft on the computer. Choose  
the communication port which is connected to the communication card presently, and the related setting.  
Click “Search” or “IP search” in the toolbar. After the search is complete, the icon of the communication  
card with the name “DVP-FEN01” appears in DCISoft. Finally, click the icon, and set the parameters  
related to the network such as the IP address. Please refer to DVP-FEN01 Application Manual for more  
information.  
Product Profile & Dimensions  
Mini DIN  
1 Port  
埠數  
Screw hole  
3
1
4
UC-MS030-01A / UC-PRG020-12A  
19,200bps  
線材  
PLC connector  
傳輸速率  
RS-232 communication port  
RJ-45 communication port  
Activity LED indicator (orange)  
Link LED indicator (green)  
Communication card removal lever  
通訊格式  
通訊協定  
Data bit8  
Parity bitNone  
Stop bit1  
MODBUS ASCII  
5
2
電氣規格  
電源電壓  
The Pins in the Mini-DIN Connector  
6
7
8
Pin  
1
Mini-DIN  
N/C  
Pin  
5
Mini-DIN  
Tx  
5VDC由主機經由 PLC 連接埠應)  
1W  
Firmware update switch  
(Please make sure the switch is  
turned off before using this  
product.)  
消耗電力  
2
N/C  
6
N/C  
(Back)  
(Side)  
16g  
重量  
(Front)  
3
N/C  
7
N/C  
環境規格  
4
Rx  
8
GND  
ESD (IEC 61131-2, IEC 61000-4-2): 8 kV Air Discharge  
The Pins in the RJ-45 Connector  
EFT (IEC 61131-2, IEC 61000-4-4): Communication I/O: ±2 kV  
CS (IEC 61131-2, IEC 61000-4-6): 0.15 ~ 80 MHz, 3 Vrms  
雜訊免疫力  
Pin  
1
RJ-45  
Tx+  
Pin  
5
RJ-45  
N/C  
操作:0°C ~ 55°C(溫度5 ~ 95%(濕度污染等級  
2
操作儲存環境  
2
Tx-  
6
Rx-  
儲存:-25°C ~ 70°C(溫度5 ~ 95%(濕度)  
3
Rx+  
7
N/C  
耐振動衝擊  
國際標準規範 IEC61131-2, IEC68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)  
4
N/C  
8
N/C  

Xerox All In One Printer 6204 User Manual
Sony L200 User Manual
Philips M2922a User Manual
NEC NP PA722X User Manual
Mitsubishi Motors Automobile Parts Aw372 User Manual
Minolta 1250e User Manual
KENWOOD KMR D362BT User Manual
Cycle Tone User Manual
BROTHER FAX 335MC User Manual
BLACK DECKER SCS600 User Manual