360101-XTG-A-0108
®
DESCRIPTION
TECHNICAL GUIDE
AFFINITY™ SERIES
These packaged cooling air conditioners are designed for
outdoor installation. Only utility and duct connections are
required at the point of installation.
Field-installed electric heater accessories are available to
provide electric heat combined with electric cooling.
SINGLE PACKAGE
COOLING UNITS
STANDARD FEATURES / BENEFITS
OPERATING EFFICIENCY - All units provide high operating
D2EB018 THRU 060
1.5 THRU 5 TON
8.8 - 9.4 EER
efficiencies and have a minimum EER of 8.8 or above.
ON SITE FLEXIBILITY - All model sizes share a common,
compact design cabinet with a single footprint. The installer has
the flexibility of setting one curb and placing the proper tonnage
unit on that curb after the internal load has been determined.
Field convertible duct connections from side shot to down shot
allows the installer to have greater flexibility and needs to carry
less inventory.
EXPORT
LOWER INSTALLATION COST - Installation time and costs
are reduced by easy power and control wiring connections. The
small base dimension means less space is required on the
ground or roof, plus, the installer can fit this unit between the
wheel wells of full size pick-up truck. All models are well under
400 pounds.
All units are completely wired, charged with R-22 and tested
prior to shipment. Unique test stations using a new state of the
art computerized process system are used to insure product
quality. Refrigerant charge, and component part numbers are
verified via computers at installation. Vital run test statistics
such as system pressure, motor currents, air velocity and
temperature and unit vibration are monitored and recorded by
the system to insure unit performance.
Equal size, side supply and return duct connections allows easy
hook-up of ducts to match low crawl spaces without transition
pieces.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
360101-XTG-A-0108
CONDENSER COIL GRILLE - A multi-piece totally enclosed,
rigidly mounted condenser coil grille provides protection from
objects and personal after installation and provides protection
during transit and installation.
STANDARD FEATURES/BENEFITS (CONT.)
UTILITY CONNECTIONS MADE EASY - Electrical utility
knockouts are provided through the bottom as well as the side
of the unit. Utility connections can be made quickly and with a
minimum amount of field labor. A field supplied and field
installed electrical disconnect switch must be installed.
LOW OPERATING SOUND LEVEL - The upward air flow carries
the normal operating noise up and away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the rippled fins of the condenser coil
muffle the normal fan motor and compressor operating sounds.
The unique formed base pan also aids in sound alterations with it's
“Super-Structure” design. This design strategically places
embossments in the pan for optimum strength and rigidity.
CONVERTIBLE AIRFLOW DESIGN - The bottom duct
openings are covered when they leave the factory ready to be
used for a side supply / side return application. If a bottom supply
/ bottom return application is desired, you simply remove the two
panels from the bottom of the unit and place them in the side
supply / side return duct openings. No panel cutting is required
and no accessory panel is necessary. Convertible airflow design
allows maximum field flexibility and minimum inventory.
FAN SYSTEM - All models operate over a wide range of design
conditions with a 3-speed direct-drive fan motor. These units
easily match all types of applications and provides greater on
site flexibility to match comfort requirement.
CONDENSATE PAN - A non-corrosive, long-lasting, water-tight
pan is positioned below the evaporator coil to collect and drain
all condensate. Less collection of stagnate condensate will
build-up. The condensate pan conforms to ASHRAE 62-89
standards (Ventilation for Acceptable Indoor Air Quality).
SIMPLE CONTROL CIRCUIT - A low voltage printed circuit
board contains a low voltage terminal strip. The electrical
control box is not located in the compressor compartment. All
wiring internal to the unit is color/number coded.
CONDENSATE DRAIN - The heavy duty, 3/4 inch NPTI copper
connection is more tolerable during installation and is more
durable over time. The connection is rigidly mounted to assure
proper fit and leak tight seal.
PROTECTED COMPRESSOR - The compressor is internally
protected against high pressure and temperature. This is
accomplished by the simultaneous operation of high pressure
relief valve and a temperature sensor which protect the
compressor if undesirable operating conditions occur.
DURABLE FINISH - With a heavy duty cabinet made of powder-
painted, galvanized steel the neutral color blends into
EXCLUSIVE COIL DESIGN - Grooved copper tubes and
enhanced aluminum fin construction improves heat transfer for
maximum efficiency and durability.
surrounding areas. The powered paint, provides a better paint to
steel bond, which resists corrosion and rust creep. The special
primer formulas and glossy earth tone finish insure less fading
when exposed to sunlight and offers a more attractive on site
appearance. This paint finish exceeds ASTM-B117 standards for
750 hours salt spray rating, the highest in the industry.
LOW MAINTENANCE - Long life, permanently lubricated
condenser and evaporator fan motor bearings need no annual
maintenance adding greater reliability to the unit. Blower
assembly can be easily removed for cleaning by the unique
“Slip- Track” slide-out blower assembly.
FULL PERIMETER BASE RAILS - The easily removable base
rails provide a solid foundation for the entire unit and protects
the unit during shipment. The rails provide fork lift access from
all sides, and rigging holes are also provided so that an
overhead crane can be used to place the units on a roof. On
applications when the unit is placed on a pad, the base will
keep the unit off the pad to deter corrosion. On applications
where height is limited, the 2-3/8 inch high base rails may be
removed on location.
SECURED SERVICE ACCESS PORTS - Protected, externally
mounted, re-usable service access ports are provided on both
the high and low lines for ease of evacuating and charging the
system. No final field mounting required.
EASY SERVICE ACCESS - A large, single panel covers the
electrical controls and makes servicing easy. The blower
compartment has an additional large panel with a built-in
handle tab. Removing this panel will allow the blower assembly
to slide-out for easy removal for maintenance and ease of
trouble shooting.
MORE ATTRACTIVE APPEARANCE - A single piece “Water
Shed” top cover containing a top discharge condenser fan
arrangement requires less square footage on installation and
provides a wider variety of installations. The one piece design
adds greater water integrity. Rounded corners with water drip
edges add to the attractive appearance. The cabinet panels
have a non-fibrous insulation that does not add insulation fibers
into conditioned area.
REPLACEMENT PARTS - The installer has no need to carry
an inventory of unique parts or needs special training to replace
any of the components parts for these units. All are easily
obtained from Source 1 or other part houses.
TOP DISCHARGE - The top discharge condenser fan does not
disrupt neighboring areas and does not dry-out vegetation
surrounding the unit. The warm air from the top mounted fan is
blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.
FIELD-INSTALLED ACCESSORIES
ECONOMIZER DOWN DISCHARGE / SUPPLY KIT -
Modulating integrated economizer provides simultaneous
operation between the mechanical cooling and economizer
Johnson Controls Unitary Products
3
360101-XTG-A-0108
operation. Independent blade design insures proper control and
less than 1% leak rate. Includes hood and mesh bird screen
filter integrated into the hood, dry bulb sensor and relief
damper. Separate field accessories of single enthalpy and dual
enthalpy are also available.
MOTORIZED FRESH AIR DAMPER - Designed for duct
mounted side return and unit mounted down shot return
applications. Damper capable of providing 0% thru 50% of
outdoor air (field supplied). Closes on power loss, includes
hood and screen assembly.
SINGLE ENTHALPY SENSOR - Sensor replaces dry bulb
sensor standard in economizer kit. Provides improved
economizer operation by sensing the dry bulb temperature from
outdoors plus the enthalpy content of the outdoor air.
RECTANGLE TO ROUND ADAPTERS - Kit includes one
supply and one return air rectangle to round duct adapter.
Adapters are preformed and designed to fit over current duct
openings on the base unit. Transition is from 15” square to 14”
round.
DUAL ENTHALPY SENSOR - Additional sensor to single
enthalpy sensor. Sensor senses both the return air temperature
dry bulb and humidity in conjunction with the single enthalpy to
determine the most economical mix. Single Enthalpy sensor
also required.
ROOF CURBS - NRCA approved curbs provide proper fit to
base unit for rooftop installations. Curbs are designed to be
assembled through hinge pins in each corner. Kit also provides
seal strip to assure a water tight seal. Eight and 14 inch high
roof curbs are available.
UPGRADE SAFETY PACKAGE - Contains screw-in type High
pressure, Low Pressure/Loss of Charge switch, freeze protection
switch and lockout relay. Switches are placed onto existing
schrader ports located in the unit by furnished adapters. When
abnormal conditions are sensed through the pressure switches,
the unit will lock out preventing any further operation until reset or
problem is corrected. Package agency approved.
MANUAL OUTDOOR DAMPER - Provides 0% thru 50%
outdoor air capability (field adjustable). Designed for duct
mounted side return and unit mounted down shot return
applications. Includes hood and screen assembly.
WALL THERMOSTAT - The units are designed to operate with
24-volt electronic and electro-mechanical thermostats. All units
can operate with single stage heat / single stage cool
thermostats - with or without the economizer.
HAIL GUARD KIT - Kit contains protected grilles made of
expanded aluminum grilles with full perimeter inch frame.
Sloped hoods are also included to assure maximum protection..
LOW AMBIENT KIT - Kit provides necessary hardware to
convert unit to operate in cooling cycle down to 0 °F. Standard
unit operation 45 °F.
ANTI SHORT CYCLE TIMER - Automatically prevents the
compressor from restarting for 5 minutes after cycled off. Not
required if Thermostat 2ET07700224 and 2ET04700224 are
used.
TRANSFORMER KIT - Kit provides necessary hardware to
provide single phase models from factory furnished 40 VA
transformer capability to 75 VA transformer capability.
FILTER / FRAME KIT (Single Phase only) - Kit contains the
necessary hardware to field install return air filters into the base
unit. Pre-cut filter racks and appropriate cleanable standard
size filters are shipped in one kit. (1" filter is supplied) This kit is
available for single phase horizontal or vertical duct application
only. Standard in all 3 Phase models.
ELECTRIC HEATERS - Each heater package provides easy
installation of electric heat strips. Slide in design with plug in
harness and agency approved. Heaters are available from 5.0
KW sizes and are designed for single point connection.
DIRECT DRIVE
CONDENSER
FAN MOTOR
HIGHLY EFFICIENT ENHANCED
COPPER TUBE/ALUMINUM FIN
EVAPORATOR COIL
BACK AND BOTTOM
RETURN AIR
HIGHLY EFFICIENT
ENHANCED COPPER
TUBE/ALUMINUM FIN
CONDENSER COIL
AND SUPPLY AIR
DUCT OPENING
DECORATIVE
PROTECTIVE
COIL GUARD
HIGH VOLTAGE
TERMINAL BLOCK
LOW VOLTAGE
TERMINAL BLOCK
LONG LASTING
POWDER PAINT
FINISH EARTH
3-SPEED DIRECT DRIVE
BLOWER MOTOR WITH
TONE COLOR
HIGH EFFICIENCY
COMPRESSOR
RIGIDLY
SLIDE-OUT BLOWER ASSEMBLY
HEAVY GAUGE
REMOVABLE
BASE RAILS
MOUNTED
FIGURE 1 - UNIT CUTAWAY
4
Johnson Controls Unitary Products
360101-XTG-A-0108
TABLE 1: PHYSICAL DATA
DEB
036
MODELS
EVAPORATOR CENTRIFUGAL BLOWER (Dia. x Wd. in.)
018
9 X 6
½
2
13
024
10 X 8
½
2
15
030
10 X 8
½
2
15
042
048
060
11 x 10
1
3
16
10 x 8
11 X 10
11 x 10
3
3
3
BLOWER
FAN MOTOR HP
ROWS DEEP
4
4
4
2
15
2
15
2
13
EVAPORATOR FINS PER INCH
COIL
FACE AREA (Sq. Ft.)
PROPELLER DIA. (in.)
2.19
22
2.81
22
4.38
22
4.38
22
4.38
22
5.62
22
5.26
22
CONDENSER FAN MOTOR HP
1/4
1,800
1
1/4
2,200
1
1/4
2,400
1
1/4
2,400
1
1/4
2,400
1
1/4
2,800
1
1/4
2,800
1
FAN
NOM. CFM TOTAL
ROWS DEEP
CONDENSER FINS PER INCH
18
16
20
18
16
13
20
COIL
CHARGE
FILTER
FACE AREA (Sq. Ft.)
REFRIGERANT 22 (lbs./oz.)
FACE AREA (Sq. Ft.) / Qty. / Size
8.3
3 / 4
8.3
3 / 5
8.3
3 / 13
8.3
3 / 10
2.14 / 2 / 14" x 22"
Recip.
11.7
4 / 8
16.4
5 / 15
16.4
5 /15
COMPRESSOR HERMETIC, QTY. = 1 (Type)
Recip.
Recip.
Recip.
Recip.
Scroll
Scroll
TABLE 2: RATINGS - ARI
Cooling Capacity1
80/67-95 °F
Electric Heat
Nom. Capacity
KW
Sound Rating2
(decibels)
Model DEB
MBH
EER
(single phase)
018
024
030
036
042
048
060
17.6
23.0
29.0
35.2
40.5
46.5
59.0
8.8
9.1
8.9
8.7
9.4
8.8
8.8
76
76
79
81
83
81
79
5.0, 7.5
5.0. 7.5. 10.0
5.0, 7.5, 10.0, 15.0
5.0, 7.5, 10.0, 15.0
5.0, 7.5, 10.0, 15.0
10.0, 15.0, 20.0, 25.0
10.0, 15.0, 20.0, 25.0
1. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.
2. Rated in accordance with ARI Standard 270.
SEER = Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the
total electric power input in watt-hours during the same period.
Johnson Controls Unitary Products
5
360101-XTG-A-0108
TABLE 3: COOLING CAPACITIES - 1-1/2 TON (DEB018)
AIR ON INDOOR COIL
600 CFM
TEMPERATURE
OF AIR ON
OUTDOOR COIL
450 CFM
WB °F
525 CFM
WB °F
67 62
675 CFM
WB °F
750 CFM
WB °F
WB °F
72
67
62
57
72
57
72
67
62
57
72
67
62
57
72
67
62
57
Net Cap
MBH
Total Power
Input kW
18.1 17.3 16.0 16.3 18.2 17.4 16.1 16.4 18.4 17.5 16.2 16.5 19.0 18.2 16.8 17.1 19.7 18.8 17.4 17.7
1.77 1.75 1.74 1.72 1.82 1.81 1.79 1.78 1.87 1.86 1.85 1.83 1.91 1.90 1.88 1.87 1.95 1.94 1.92 1.91
86
83
80
77
74
71
68
10.1 13.1 15.9 16.3 10.8 14.0 16.1 16.4 11.5 14.8 16.2 16.5 12.3 15.7 16.8 17.1 13.1 16.7 17.4 17.7
8.8 11.8 14.7 16.0 9.3 12.4 15.4 16.3 9.8 13.0 16.0 16.5 10.3 13.7 16.7 17.1 10.9 14.4 17.4 17.7
7.5 10.6 13.4 14.7 7.8 10.9 13.8 15.2 8.0 11.3 14.3 15.7 8.3 11.7 14.9 16.3 8.7 12.2 15.5 17.0
6.2 9.3 12.1 13.4 6.2 9.4 12.3 13.7 6.3 9.5 12.5 14.0 6.3 9.8 12.9 14.4 6.4 10.0 13.2 14.8
4.9 8.0 10.8 12.1 4.7 7.9 10.8 12.2 4.5 7.8 10.8 12.2 4.4 7.8 10.9 12.4 4.2 7.7 11.0 12.5
85 °F
-
-
6.7 9.5 10.9
5.4 8.2 9.6
-
-
6.4 9.3 10.7
4.9 7.8 9.1
-
-
6.0 9.0 10.5
4.3 7.3 8.7
-
-
5.8 8.9 10.4
3.8 6.9 8.4
-
-
5.5 8.8 10.3
3.3 6.5 8.1
Net Cap
MBH
Total Power
Input kW
16.2 16.1 13.7 14.1 17.0 16.8 14.3 14.8 17.8 17.6 15.0 15.5 18.0 17.8 15.1 15.6 18.1 17.9 15.3 15.8
1.88 1.89 1.84 1.84 1.94 1.95 1.90 1.89 1.99 2.00 1.95 1.95 2.02 2.03 1.98 1.97 2.04 2.05 2.00 2.00
86
83
80
77
74
71
68
9.1 12.6 13.7 14.1 10.2 14.1 14.3 14.8 11.3 15.5 15.0 15.5 11.9 16.2 15.1 15.6 12.5 16.8 15.3 15.8
7.9 11.4 13.2 13.6 8.7 12.6 14.1 14.6 9.6 13.8 15.0 15.5 9.9 14.2 15.1 15.6 10.3 14.6 15.3 15.8
6.6 10.1 11.9 12.3 7.2 11.0 13.1 13.5 7.8 12.0 14.3 14.7 7.9 12.2 14.4 14.9 8.1 12.3 14.6 15.1
5.3 8.8 10.7 11.1 5.7 9.5 11.6 12.0 6.1 10.3 12.5 13.0 6.0 10.2 12.5 12.9 5.8 10.1 12.4 12.9
4.0 7.5 9.4 9.8 4.2 8.0 10.1 10.5 4.3 8.5 10.8 11.2 4.0 8.2 10.5 10.9 3.6 7.9 10.2 10.7
95 °F
-
-
6.2 8.1 8.5
4.9 6.8 7.2
-
-
6.5 8.6 9.0
5.0 7.0 7.5
-
-
6.8 9.0 9.5
5.0 7.3 7.7
-
-
6.2 8.5 9.0
4.2 6.5 7.0
-
-
5.6 7.9 8.4
3.4 5.7 6.2
Net Cap
MBH
Total Power
Input kW
15.2 14.6 12.7 13.2 15.9 15.2 13.3 13.8 16.6 15.9 13.9 14.3 16.9 16.2 14.1 14.6 17.2 16.5 14.4 14.9
1.99 2.00 1.96 1.94 2.05 2.06 2.02 2.00 2.11 2.12 2.08 2.06 2.14 2.15 2.10 2.09 2.16 2.17 2.13 2.11
86
83
80
77
74
71
68
8.7 12.0 12.7 13.2 9.8 13.4 13.3 13.8 10.9 14.8 13.9 14.3 11.6 15.4 14.1 14.6 12.3 15.9 14.4 14.9
7.4 10.7 12.4 12.6 8.3 11.9 13.1 13.5 9.2 13.2 13.9 14.3 9.6 13.7 14.1 14.6 10.1 14.2 14.4 14.9
6.2 9.4 11.1 11.3 6.8 10.4 12.2 12.5 7.4 11.4 13.4 13.6 7.6 11.7 13.7 14.0 7.8 12.0 14.1 14.4
4.9 8.1 9.8 10.0 5.3 8.9 10.7 10.9 5.7 9.7 11.6 11.9 5.6 9.7 11.7 12.0 5.6 9.8 11.8 12.1
3.6 6.9 8.5 8.7 3.8 7.4 9.2 9.4 3.9 7.9 9.9 10.1 3.7 7.7 9.8 10.0 3.4 7.5 9.6 9.9
105 °F
115 °F
125 °F
-
-
5.6 7.2 7.4
4.3 5.9 6.2
-
-
5.9 7.7 7.9
4.3 6.2 6.4
-
-
6.2 8.1 8.4
4.4 6.4 6.6
-
-
5.7 7.8 8.0
3.7 5.8 6.0
-
-
5.3 7.4 7.6
3.1 5.1 5.4
Net Cap
MBH
Total Power
Input kW
14.3 13.1 11.8 12.2 14.8 13.6 12.3 12.7 15.4 14.2 12.8 13.2 15.9 14.6 13.2 13.6 16.3 15.0 13.5 14.0
2.10 2.11 2.07 2.04 2.17 2.17 2.14 2.11 2.23 2.24 2.21 2.18 2.26 2.27 2.23 2.20 2.28 2.29 2.26 2.22
86
83
80
77
74
71
68
8.3 11.3 11.8 12.2 9.4 12.8 12.3 12.7 10.5 14.2 12.8 13.2 11.3 14.6 13.2 13.6 12.1 15.0 13.5 14.0
7.0 10.1 11.5 11.5 7.9 11.3 12.1 12.4 8.8 12.5 12.8 13.2 9.3 13.2 13.2 13.6 9.8 13.9 13.5 14.0
5.7 8.8 10.2 10.2 6.4 9.8 11.4 11.4 7.0 10.8 12.5 12.6 7.3 11.2 13.0 13.1 7.6 11.7 13.5 13.6
4.4 7.5 8.9 8.9 4.9 8.3 9.9 9.9 5.3 9.0 10.8 10.8 5.3 9.2 11.0 11.1 5.4 9.4 11.3 11.3
3.2 6.2 7.6 7.7 3.3 6.8 8.3 8.4 3.5 7.3 9.0 9.1 3.3 7.2 9.0 9.1 3.1 7.2 9.1 9.1
-
-
4.9 6.4 6.4
3.6 5.1 5.1
-
-
5.2 6.8 6.8
3.7 5.3 5.3
-
-
5.5 7.3 7.3
3.8 5.5 5.6
-
-
5.3 7.1 7.1
3.3 5.1 5.1
-
-
5.0 6.8 6.9
2.7 4.6 4.6
Net Cap
MBH
Total Power
Input kW
13.3 11.6 10.9 11.3 13.7 12.0 11.3 11.7 14.2 12.4 11.7 12.1 14.8 13.0 12.2 12.6 15.4 13.5 12.7 13.1
2.2 2.2 2.2 2.1 2.3 2.3 2.3 2.2 2.4 2.4 2.3 2.3 2.4 2.4 2.4 2.3 2.4 2.4 2.4 2.3
86
83
80
77
74
71
68
7.9 10.7 10.9 11.3 9.0 12.1 11.3 11.7 10.1 13.5 11.7 12.1 11.0 13.8 12.2 12.6 11.9 14.1 12.7 13.1
6.6 9.4 10.6 10.4 7.5 10.7 11.1 11.3 8.4 11.9 11.7 12.1 9.0 12.7 12.2 12.6 9.6 13.6 12.7 13.1
5.3 8.1 9.3 9.2 6.0 9.2 10.5 10.3 6.6 10.2 11.7 11.5 7.0 10.8 12.3 12.1 7.4 11.3 13.0 12.8
4.0 6.9 8.1 7.9 4.5 7.6 9.0 8.8 4.9 8.4 9.9 9.7 5.0 8.8 10.3 10.1 5.2 9.1 10.7 10.6
2.7 5.6 6.8 6.6 2.9 6.1 7.5 7.3 3.1 6.7 8.2 8.0 3.0 6.8 8.3 8.2 2.9 6.9 8.5 8.3
-
-
4.3 5.5 5.3
3.0 4.2 4.0
-
-
4.6 6.0 5.8
3.1 4.4 4.2
-
-
4.9 6.4 6.2
3.2 4.7 4.5
-
-
4.8 6.3 6.2
2.8 4.4 4.2
-
-
4.6 6.3 6.1
2.4 4.0 3.9
1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity
ALL SENSIBLE CAPACITIES
6
Johnson Controls Unitary Products
360101-XTG-A-0108
TABLE 4: COOLING CAPACITIES - 2 TON (DEB024)
AIR ON INDOOR COIL
800 CFM
TEMPERATURE
600 CFM
700 CFM
WB °F
900 CFM
WB °F
1,000 CFM
WB °F
OF AIR ON
WB °F
WB °F
OUTDOOR COIL
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
Net Cap
MBH
Total Power
Input kW
25.1 23.0 21.2 20.7 26.1 23.9 22.0 21.5 27.0 24.8 22.8 22.3 27.2 24.9 22.9 22.4 27.3 25.0 23.0 22.5
2.33 2.34 2.30 2.26 2.39 2.40 2.35 2.31 2.44 2.45 2.40 2.36 2.57 2.58 2.53 2.49 2.71 2.72 2.66 2.62
86
83
80
77
74
71
68
14.8 18.5 21.2 20.7 16.2 20.1 22.0 21.5 17.5 21.7 22.8 22.3 18.6 23.0 22.9 22.4 19.7 24.2 23.0 22.5
13.1 16.8 20.7 20.7 14.2 18.1 21.8 21.5 15.2 19.4 22.8 22.3 16.0 20.3 22.9 22.4 16.7 21.2 23.0 22.5
11.4 15.1 19.0 19.6 12.1 16.1 20.2 20.9 12.9 17.1 21.5 22.1 13.3 17.6 22.2 22.3 13.8 18.2 22.9 22.5
9.7 13.4 17.3 17.9 10.1 14.1 18.2 18.8 10.5 14.7 19.2 19.8 10.7 15.0 19.6 19.7 10.8 15.2 20.0 19.5
8.0 11.7 15.6 16.2 8.1 12.0 16.2 16.8 8.2 12.4 16.8 17.5 8.0 12.3 16.9 17.0 7.8 12.3 17.0 16.5
85 °F
-
-
10.0 13.9 14.4
8.2 12.2 12.7
-
-
10.0 14.2 14.8
8.0 12.2 12.8
-
-
10.1 14.5 15.1
7.7 12.2 12.8
-
-
9.7 14.2 14.3
7.0 11.6 11.7
-
-
9.3 14.0 13.6
6.3 11.0 10.6
Net Cap
MBH
Total Power
Input kW
23.8 21.4 19.7 20.2 24.7 22.2 20.4 21.0 25.7 23.0 21.2 21.8 25.8 23.1 21.3 21.9 25.9 23.2 21.4 22.0
2.49 2.46 2.44 2.39 2.54 2.51 2.49 2.44 2.59 2.56 2.54 2.49 2.74 2.71 2.68 2.63 2.89 2.86 2.83 2.77
86
83
80
77
74
71
68
14.2 17.6 19.7 20.2 15.7 19.4 20.4 21.0 17.2 21.1 21.2 21.8 18.3 22.2 21.3 21.9 19.4 23.2 21.4 22.0
12.5 15.9 19.5 19.4 13.7 17.3 20.3 20.6 14.9 18.8 21.2 21.8 15.7 19.7 21.3 21.9 16.5 20.7 21.4 22.0
10.8 14.2 17.7 17.7 11.7 15.3 19.1 19.1 12.5 16.4 20.5 20.5 13.0 17.1 21.0 21.2 13.5 17.7 21.4 22.0
9.1 12.5 16.0 16.0 9.6 13.3 17.1 17.1 10.2 14.1 18.2 18.2 10.3 14.4 18.3 18.6 10.5 14.7 18.4 19.0
7.4 10.8 14.3 14.3 7.6 11.3 15.1 15.0 7.9 11.8 15.9 15.8 7.7 11.8 15.6 15.9 7.5 11.7 15.4 16.0
95 °F
-
-
9.1 12.6 12.6
7.4 10.9 10.9
-
-
9.3 13.1 13.0
7.2 11.1 11.0
-
-
9.4 13.5 13.5
7.1 11.2 11.2
-
-
9.1 13.0 13.3
6.4 10.3 10.6
-
-
8.8 12.4 13.0
5.8 9.5 10.0
Net Cap
MBH
Total Power
Input kW
21.5 19.0 17.9 17.9 22.5 19.9 18.7 18.7 23.5 20.8 19.6 19.5 23.6 20.8 19.6 19.6 23.7 20.9 19.7 19.7
2.61 2.58 2.55 2.51 2.67 2.64 2.60 2.56 2.72 2.69 2.65 2.62 2.87 2.84 2.79 2.76 3.01 2.98 2.93 2.90
86
83
80
77
74
71
68
13.4 16.7 17.9 17.9 14.9 18.3 18.7 18.7 16.4 19.8 19.6 19.5 17.5 20.4 19.6 19.6 18.6 20.9 19.7 19.7
11.7 15.0 17.7 17.5 12.9 16.5 18.6 18.5 14.0 18.0 19.6 19.5 14.8 18.8 19.6 19.6 15.6 19.7 19.7 19.7
9.9 13.3 16.0 15.9 10.8 14.5 17.4 17.3 11.7 15.7 18.8 18.7 12.2 16.3 19.3 19.2 12.6 16.9 19.7 19.7
8.2 11.6 14.3 14.2 8.8 12.5 15.4 15.3 9.4 13.4 16.5 16.4 9.5 13.7 16.6 16.5 9.6 13.9 16.7 16.7
6.5 9.9 12.6 12.5 6.8 10.5 13.4 13.3 7.0 11.0 14.2 14.1 6.9 11.0 14.0 13.9 6.7 11.0 13.8 13.7
105 °F
115 °F
125 °F
-
-
8.2 10.9 10.8
6.5 9.1 9.1
-
-
8.4 11.3 11.2
6.4 9.3 9.2
-
-
8.7 11.8 11.7
6.4 9.5 9.4
-
-
8.3 11.3 11.2
5.7 8.6 8.6
-
-
8.0 10.8 10.7
5.0 7.8 7.7
Net Cap
MBH
Total Power
Input kW
19.2 16.7 16.1 15.5 20.2 17.6 17.0 16.4 21.3 18.5 17.9 17.2 21.4 18.6 18.0 17.3 21.4 18.7 18.1 17.3
2.74 2.70 2.65 2.63 2.80 2.76 2.71 2.69 2.86 2.82 2.77 2.75 3.00 2.96 2.91 2.88 3.14 3.10 3.04 3.02
86
83
80
77
74
71
68
12.5 15.9 16.1 15.5 14.0 17.2 17.0 16.4 15.6 18.5 17.9 17.2 16.7 18.6 18.0 17.3 17.7 18.7 18.1 17.3
10.8 14.2 15.9 15.5 12.0 15.7 16.9 16.4 13.2 17.3 17.9 17.2 14.0 18.0 18.0 17.3 14.8 18.7 18.1 17.3
9.1 12.4 14.2 14.1 10.0 13.7 15.7 15.5 10.9 14.9 17.1 17.0 11.3 15.5 17.6 17.1 11.8 16.1 18.1 17.3
7.4 10.7 12.5 12.4 8.0 11.7 13.6 13.5 8.6 12.6 14.8 14.6 8.7 12.9 14.9 14.5 8.8 13.1 15.1 14.4
5.7 9.0 10.8 10.7 6.0 9.7 11.6 11.5 6.2 10.3 12.4 12.3 6.0 10.2 12.3 11.8 5.8 10.2 12.1 11.4
-
-
7.3 9.1 9.0
5.6 7.4 7.3
-
-
7.6 9.6 9.5
5.6 7.6 7.4
-
-
7.9 10.1 10.0
5.6 7.8 7.6
-
-
7.6 9.6 9.2
4.9 6.9 6.5
-
-
7.2 9.1 8.4
4.2 6.1 5.4
Net Cap
MBH
Total Power
Input kW
16.9 14.3 14.4 13.2 18.0 15.3 15.3 14.0 19.1 16.2 16.3 14.9 19.2 16.3 16.3 15.0 19.2 16.4 16.4 15.0
2.9 2.8 2.8 2.8 2.9 2.9 2.8 2.8 3.0 3.0 2.9 2.9 3.1 3.1 3.0 3.0 3.3 3.2 3.1 3.1
86
83
80
77
74
71
68
11.6 15.0 14.4 13.2 13.2 16.1 15.3 14.0 14.8 17.2 16.3 14.9 15.8 16.8 16.3 15.0 16.9 16.4 16.4 15.0
9.9 13.3 14.2 13.6 11.2 14.9 15.2 14.2 12.4 16.5 16.3 14.9 13.2 17.1 16.3 15.0 13.9 17.6 16.4 15.0
8.2 11.6 12.5 12.3 9.2 12.9 13.9 13.8 10.1 14.2 15.4 15.2 10.5 14.8 15.9 15.1 10.9 15.3 16.4 15.0
6.5 9.9 10.8 10.6 7.1 10.9 11.9 11.7 7.8 11.9 13.0 12.9 7.9 12.1 13.2 12.4 7.9 12.4 13.4 12.0
4.8 8.2 9.1 8.9 5.1 8.8 9.9 9.7 5.4 9.5 10.7 10.5 5.2 9.5 10.6 9.8 5.0 9.4 10.4 9.1
-
-
6.4 7.3 7.2
4.7 5.6 5.5
-
-
6.8 7.9 7.7
4.8 5.8 5.7
-
-
7.2 8.4 8.2
4.9 6.0 5.9
-
-
6.8 7.9 7.1
4.1 5.2 4.5
-
-
6.4 7.4 6.1
3.4 4.5 3.1
1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity
ALL SENSIBLE CAPACITIES
Johnson Controls Unitary Products
7
360101-XTG-A-0108
TABLE 5: COOLING CAPACITIES - 2-1/2 TON (DEB030)
AIR ON INDOOR COIL
1,000 CFM
TEMPERATURE
OF AIR ON
OUTDOOR COIL
750 CFM
WB °F
875 CFM
WB °F
67 62
1,125 CFM
WB °F
1,250 CFM
WB °F
WB °F
72
67
62
57
72
57
72
67
62
57
72
67
62
57
72
67
62
57
Net Cap
MBH
Total Power
Input kW
32.3 29.8 27.5 28.1 32.6 30.1 27.8 28.4 33.0 30.4 28.1 28.7 33.5 30.9 28.4 29.1 33.9 31.3 28.8 29.5
2.94 2.92 2.83 2.81 3.02 3.00 2.90 2.88 3.10 3.08 2.98 2.96 3.20 3.18 3.08 3.06 3.31 3.28 3.18 3.16
86
83
80
77
74
71
68
18.2 23.6 27.5 28.1 20.1 25.8 27.8 28.4 21.9 28.0 28.1 28.7 23.3 29.6 28.4 29.1 24.8 31.3 28.8 29.5
16.1 21.4 25.5 26.3 17.5 23.3 26.8 27.5 19.0 25.1 28.1 28.7 20.0 26.4 28.4 29.1 21.1 27.7 28.8 29.5
14.0 19.3 23.3 24.1 15.0 20.7 25.1 25.9 16.0 22.2 26.8 27.7 16.7 23.1 27.8 28.6 17.3 24.0 28.8 29.5
11.8 17.2 21.2 22.0 12.5 18.2 22.5 23.4 13.1 19.3 23.9 24.8 13.4 19.7 24.5 25.3 13.6 20.2 25.1 25.8
9.7 15.0 19.1 19.9 10.0 15.7 20.0 20.9 10.2 16.3 21.0 21.9 10.1 16.4 21.2 22.0 9.9 16.5 21.4 22.1
85 °F
-
-
12.9 16.9 17.7
10.8 14.8 15.6
-
-
13.2 17.5 18.3
10.6 15.0 15.8
-
-
13.4 18.0 19.0
10.5 15.1 16.1
-
-
13.1 17.9 18.7
9.8 14.5 15.3
-
-
12.8 17.7 18.4
9.1 13.9 14.6
Net Cap
MBH
Total Power
Input kW
29.1 27.5 24.4 24.8 30.2 28.6 25.3 25.7 31.3 29.7 26.2 26.7 30.9 29.3 25.9 26.4 30.5 28.9 25.6 26.0
3.17 3.11 3.04 3.03 3.24 3.17 3.10 3.09 3.30 3.23 3.16 3.15 3.43 3.36 3.29 3.27 3.56 3.49 3.41 3.39
86
83
80
77
74
71
68
17.5 22.2 24.4 24.8 19.5 24.7 25.3 25.7 21.6 27.2 26.2 26.7 23.1 28.1 25.9 26.4 24.6 28.9 25.6 26.0
15.4 20.1 24.1 23.9 17.0 22.2 25.2 25.3 18.7 24.3 26.2 26.7 19.8 25.7 25.9 26.4 20.9 27.0 25.6 26.0
13.2 18.0 22.0 21.8 14.5 19.7 24.1 23.8 15.8 21.4 26.2 25.9 16.5 22.4 25.9 26.0 17.2 23.3 25.6 26.0
11.1 15.8 19.9 19.6 12.0 17.2 21.6 21.3 12.8 18.5 23.3 23.0 13.1 19.0 22.6 22.6 13.4 19.6 21.8 22.3
9.0 13.7 17.7 17.5 9.4 14.6 19.1 18.8 9.9 15.6 20.4 20.1 9.8 15.7 19.2 19.3 9.7 15.9 18.1 18.6
95 °F
-
-
11.6 15.6 15.3
9.4 13.5 13.2
-
-
12.1 16.5 16.3
9.6 14.0 13.7
-
-
12.7 17.5 17.2
9.7 14.6 14.3
-
-
12.4 15.9 16.0
9.1 12.6 12.7
-
-
12.1 14.4 14.8
8.4 10.6 11.1
Net Cap
MBH
Total Power
Input kW
26.7 24.8 22.2 22.3 27.8 25.8 23.1 23.2 28.9 26.8 24.0 24.1 28.6 26.5 23.7 23.9 28.3 26.3 23.5 23.6
3.38 3.28 3.22 3.22 3.45 3.35 3.29 3.28 3.52 3.42 3.36 3.35 3.66 3.55 3.49 3.48 3.79 3.68 3.62 3.61
86
83
80
77
74
71
68
16.5 21.3 22.2 22.3 18.5 23.4 23.1 23.2 20.5 25.6 24.0 24.1 22.0 25.9 23.7 23.9 23.5 26.3 23.5 23.6
14.4 19.2 22.0 21.8 16.0 21.2 23.0 22.9 17.6 23.3 24.0 24.1 18.7 24.3 23.7 23.9 19.7 25.3 23.5 23.6
12.3 17.0 19.8 19.6 13.5 18.7 21.8 21.6 14.7 20.4 23.8 23.5 15.4 21.3 23.6 23.6 16.0 22.2 23.5 23.6
10.1 14.9 17.7 17.5 10.9 16.2 19.3 19.0 11.8 17.5 20.9 20.6 12.0 18.0 20.3 20.3 12.3 18.5 19.8 19.9
8.0 12.7 15.6 15.3 8.4 13.7 16.8 16.5 8.9 14.6 17.9 17.7 8.7 14.7 17.0 16.9 8.6 14.8 16.0 16.2
105 °F
115 °F
125 °F
-
-
10.6 13.4 13.2
8.5 11.3 11.1
-
-
11.1 14.2 14.0
8.6 11.7 11.5
-
-
11.7 15.0 14.8
8.7 12.1 11.9
-
-
11.4 13.7 13.6
8.0 10.3 10.3
-
-
11.0 12.3 12.5
7.3 8.6 8.7
Net Cap
MBH
Total Power
Input kW
24.3 22.0 20.0 19.8 25.4 22.9 20.8 20.7 26.4 23.9 21.7 21.5 26.2 23.7 21.6 21.4 26.1 23.6 21.4 21.3
3.58 3.45 3.41 3.41 3.66 3.52 3.48 3.48 3.74 3.60 3.56 3.56 3.89 3.74 3.69 3.69 4.03 3.87 3.83 3.83
86
83
80
77
74
71
68
15.6 20.3 20.0 19.8 17.5 22.1 20.8 20.7 19.5 23.9 21.7 21.5 20.9 23.7 21.6 21.4 22.3 23.6 21.4 21.3
13.4 18.2 19.8 19.6 15.0 20.3 20.7 20.6 16.5 22.3 21.7 21.5 17.6 23.0 21.6 21.4 18.6 23.6 21.4 21.3
11.3 16.1 17.7 17.5 12.5 17.7 19.5 19.3 13.6 19.4 21.3 21.1 14.2 20.3 21.4 21.2 14.9 21.1 21.4 21.3
9.1 13.9 15.5 15.3 9.9 15.2 17.0 16.8 10.7 16.5 18.4 18.2 10.9 16.9 18.1 17.9 11.1 17.4 17.7 17.6
7.0 11.8 13.4 13.2 7.4 12.7 14.4 14.2 7.8 13.6 15.5 15.3 7.6 13.6 14.7 14.6 7.4 13.7 14.0 13.8
-
-
9.6 11.2 11.1
7.5 9.1 8.9
-
-
10.1 11.9 11.7
7.6 9.4 9.2
-
-
10.6 12.6 12.4
7.7 9.7 9.5
-
-
10.3 11.4 11.2
7.0 8.1 7.9
-
-
10.0 10.2 10.1
6.2 6.5 6.4
Net Cap
MBH
Total Power
Input kW
21.9 19.2 17.8 17.4 22.9 20.1 18.6 18.2 23.9 21.0 19.4 19.0 23.9 21.0 19.4 18.9 23.9 20.9 19.4 18.9
3.8 3.6 3.6 3.6 3.9 3.7 3.7 3.7 4.0 3.8 3.8 3.8 4.1 3.9 3.9 3.9 4.3 4.1 4.0 4.0
86
83
80
77
74
71
68
14.6 19.4 17.8 17.4 16.5 20.8 18.6 18.2 18.4 22.2 19.4 19.0 19.8 21.6 19.4 18.9 21.2 20.9 19.4 18.9
12.5 17.2 17.6 17.5 14.0 19.3 18.5 18.2 15.5 21.3 19.4 19.0 16.5 21.6 19.4 18.9 17.4 21.9 19.4 18.9
10.3 15.1 15.5 15.3 11.4 16.7 17.2 17.0 12.6 18.4 18.9 18.7 13.1 19.2 19.1 18.8 13.7 20.1 19.4 18.9
8.2 13.0 13.3 13.2 8.9 14.2 14.7 14.5 9.6 15.5 16.0 15.8 9.8 15.9 15.8 15.5 10.0 16.3 15.6 15.2
6.0 10.8 11.2 11.1 6.4 11.7 12.1 12.0 6.7 12.6 13.1 12.9 6.5 12.6 12.5 12.2 6.3 12.6 11.9 11.5
-
-
8.7 9.1 8.9
6.5 6.9 6.8
-
-
9.2 9.6 9.4
6.6 7.1 6.9
-
-
9.6 10.1 10.0
6.7 7.2 7.0
-
-
9.3 9.2 8.9
5.9 5.8 5.5
-
-
8.9 8.2 7.7
5.2 4.5 4.0
1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity
ALL SENSIBLE CAPACITIES
8
Johnson Controls Unitary Products
360101-XTG-A-0108
TABLE 6: COOLING CAPACITIES - 3 TON (DEB036)
AIR ON INDOOR COIL
TEMPERATURE
900 CFM
1,050
WB °F
1,200
WB °F
1,350
1,500
OF AIR ON
WB °F
WB °F
WB °F
OUTDOOR COIL
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
Net Cap
MBH
Total Power
Input kW
34.7 32.3 28.5 28.4 36.9 34.3 30.3 30.1 39.0 36.4 32.1 31.9 39.9 37.1 32.7 32.6 40.7 37.9 33.4 33.2
3.61 3.52 3.46 3.46 3.62 3.53 3.47 3.47 3.63 3.55 3.48 3.48 3.70 3.61 3.55 3.55 3.77 3.68 3.61 3.61
86
83
80
77
74
71
68
19.7 25.4 28.5 28.4 22.2 28.5 30.3 30.1 24.6 31.5 32.1 31.9 26.3 33.5 32.7 32.6 28.0 35.5 33.4 33.2
17.2 22.9 26.7 28.4 19.2 25.5 29.4 30.1 21.1 28.0 32.1 31.9 22.4 29.5 32.7 32.6 23.6 31.0 33.4 33.2
14.6 20.3 24.2 26.0 16.1 22.4 26.7 28.7 17.6 24.5 29.2 31.4 18.4 25.6 30.4 32.3 19.1 26.6 31.6 33.2
12.0 17.7 21.6 23.4 13.1 19.4 23.7 25.6 14.1 21.0 25.7 27.9 14.4 21.6 26.4 28.3 14.6 22.1 27.2 28.8
9.5 15.2 19.1 20.8 10.1 16.4 20.6 22.6 10.6 17.5 22.2 24.4 10.4 17.6 22.5 24.3 10.2 17.6 22.7 24.3
85 °F
-
-
12.6 16.5 18.3
10.0 13.9 15.7
-
-
13.3 17.6 19.6
10.3 14.6 16.5
-
-
14.1 18.7 20.9
10.6 15.2 17.4
-
-
13.6 18.5 20.4
9.6 14.5 16.4
-
-
13.2 18.2 19.8
8.7 13.7 15.4
Net Cap
MBH
Total Power
Input kW
32.5 30.4 27.8 26.8 34.4 32.2 29.4 28.4 36.3 34.0 31.0 29.9 37.2 34.8 31.8 30.7 38.1 35.7 32.6 31.5
3.85 3.74 3.70 3.68 3.85 3.75 3.71 3.68 3.86 3.75 3.71 3.69 3.93 3.82 3.78 3.76 4.01 3.90 3.86 3.83
86
83
80
77
74
71
68
18.5 24.3 27.8 26.8 21.0 27.4 29.4 28.4 23.4 30.5 31.0 29.9 24.8 32.0 31.8 30.7 26.1 33.4 32.6 31.5
16.0 21.7 25.7 26.6 18.0 24.4 28.4 28.2 19.9 27.0 31.0 29.9 20.8 28.0 31.8 30.7 21.6 29.0 32.6 31.5
13.4 19.2 23.2 24.0 14.9 21.3 25.8 26.7 16.4 23.5 28.4 29.4 16.8 24.0 29.0 30.0 17.1 24.5 29.6 30.7
10.8 16.6 20.6 21.4 11.9 18.3 22.8 23.7 12.9 20.0 24.9 25.9 12.8 20.0 25.0 26.1 12.7 20.0 25.1 26.2
8.3 14.0 18.0 18.9 8.9 15.3 19.7 20.6 9.4 16.5 21.4 22.4 8.8 16.0 21.0 22.1 8.2 15.5 20.7 21.7
95 °F
-
-
11.5 15.5 16.3
8.9 12.9 13.7
-
-
12.2 16.7 17.6
9.2 13.7 14.6
-
-
13.0 17.9 18.9
9.5 14.4 15.4
-
-
12.0 17.1 18.1
8.1 13.1 14.1
-
-
11.1 16.2 17.3
6.6 11.7 12.8
Net Cap
MBH
Total Power
Input kW
29.5 27.4 25.0 24.4 31.4 29.2 26.6 26.0 33.3 31.0 28.2 27.6 34.1 31.7 28.9 28.3 35.0 32.5 29.6 29.0
4.05 3.92 3.93 3.85 4.07 3.94 3.95 3.87 4.09 3.96 3.97 3.89 4.15 4.02 4.02 3.95 4.21 4.08 4.08 4.00
86
83
80
77
74
71
68
17.5 23.3 25.0 24.4 19.9 26.3 26.6 26.0 22.3 29.2 28.2 27.6 23.6 30.3 28.9 28.3 24.8 31.4 29.6 29.0
15.0 20.7 24.0 24.3 16.9 23.3 26.1 25.9 18.8 25.9 28.2 27.6 19.6 26.8 28.9 28.3 20.3 27.6 29.6 29.0
12.4 18.1 21.4 21.7 13.9 20.3 23.9 24.3 15.3 22.4 26.5 26.8 15.6 22.8 26.9 27.3 15.8 23.1 27.3 27.7
9.8 15.6 18.8 19.1 10.8 17.3 20.9 21.2 11.8 18.9 23.0 23.3 11.6 18.8 22.9 23.3 11.4 18.7 22.8 23.2
7.3 13.0 16.3 16.6 7.8 14.2 17.9 18.2 8.3 15.4 19.5 19.8 7.6 14.8 18.9 19.3 6.9 14.2 18.4 18.8
105 °F
115 °F
125 °F
-
-
10.4 13.7 14.0
7.9 11.1 11.4
-
-
11.2 14.8 15.2
8.2 11.8 12.1
-
-
11.9 16.0 16.3
8.4 12.5 12.8
-
-
10.8 14.9 15.3
6.9 10.9 11.3
-
-
9.7 13.9 14.3
5.3 9.4 9.8
Net Cap
MBH
Total Power
Input kW
26.5 24.4 22.2 22.0 28.4 26.2 23.8 23.6 30.4 28.0 25.5 25.2 31.1 28.6 26.1 25.8 31.8 29.3 26.7 26.4
4.25 4.11 4.16 4.03 4.28 4.14 4.19 4.06 4.31 4.17 4.22 4.09 4.36 4.21 4.27 4.13 4.40 4.25 4.31 4.17
86
83
80
77
74
71
68
16.5 22.2 22.2 22.0 18.9 25.1 23.8 23.6 21.2 28.0 25.5 25.2 22.4 28.6 26.1 25.8 23.5 29.3 26.7 26.4
14.0 19.7 22.2 22.0 15.9 22.3 23.8 23.6 17.7 24.9 25.5 25.2 18.4 25.6 26.1 25.8 19.0 26.3 26.7 26.4
11.4 17.1 19.6 19.4 12.8 19.2 22.1 21.8 14.2 21.4 24.5 24.3 14.4 21.6 24.8 24.5 14.5 21.8 25.0 24.7
8.8 14.5 17.1 16.9 9.8 16.2 19.0 18.8 10.7 17.9 21.0 20.8 10.4 17.6 20.8 20.5 10.1 17.3 20.5 20.3
6.3 12.0 14.5 14.3 6.8 13.2 16.0 15.8 7.2 14.4 17.5 17.3 6.4 13.6 16.8 16.5 5.6 12.9 16.1 15.8
-
-
9.4 11.9 11.7
6.8 9.4 9.2
-
-
10.1 13.0 12.7
7.1 9.9 9.7
-
-
10.9 14.0 13.8
7.4 10.5 10.3
-
-
9.6 12.8 12.5
5.6 8.8 8.6
-
-
8.4 11.6 11.3
3.9 7.1 6.9
Net Cap
MBH
Total Power
Input kW
23.5 21.4 19.4 19.6 25.4 23.2 21.1 21.3 27.4 25.0 22.7 22.9 28.0 25.5 23.2 23.4 28.6 26.1 23.7 23.9
4.5 4.3 4.4 4.2 4.5 4.3 4.4 4.2 4.5 4.4 4.5 4.3 4.6 4.4 4.5 4.3 4.6 4.4 4.5 4.3
86
83
80
77
74
71
68
15.5 21.2 19.4 19.6 17.8 24.0 21.1 21.3 20.1 26.7 22.7 22.9 21.2 27.0 23.2 23.4 22.2 27.2 23.7 23.9
13.0 18.6 20.4 19.7 14.8 21.2 21.6 21.3 16.6 23.8 22.7 22.9 17.2 24.4 23.2 23.4 17.7 24.9 23.7 23.9
10.4 16.1 17.9 17.1 11.8 18.2 20.2 19.4 13.1 20.3 22.6 21.7 13.2 20.4 22.6 21.7 13.2 20.4 22.7 21.8
7.8 13.5 15.3 14.6 8.7 15.2 17.2 16.4 9.6 16.8 19.1 18.2 9.2 16.4 18.7 17.7 8.8 16.0 18.2 17.3
5.3 10.9 12.7 12.0 5.7 12.1 14.2 13.3 6.1 13.3 15.6 14.7 5.2 12.4 14.7 13.8 4.3 11.5 13.8 12.8
-
-
8.4 10.2 9.4
5.8 7.6 6.9
-
-
9.1 11.1 10.3
6.1 8.1 7.3
-
-
9.8 12.1 11.2
6.3 8.6 7.7
-
-
8.4 10.7 9.8
4.4 6.7 5.8
-
-
7.0 9.3 8.4
2.6 4.8 3.9
1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity
ALL SENSIBLE CAPACITIES
Johnson Controls Unitary Products
9
360101-XTG-A-0108
TABLE 7: COOLING CAPACITIES - 3-1/2 TON (DEB042)
AIR ON INDOOR COIL
TEMPERATURE
1,050 CFM
1,225
WB °F
1,400
WB °F
1,575
1,750
OF AIR ON
WB °F
WB °F
WB °F
OUTDOOR COIL
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
Net Cap
MBH
Total Power
Input kW
40.7 39.0 36.5 34.1 42.0 40.3 37.7 35.2 43.3 41.6 38.8 36.3 43.9 42.1 39.3 36.8 44.4 42.6 39.8 37.2
4.09 3.82 3.77 3.75 4.16 3.89 3.83 3.81 4.23 3.95 3.90 3.88 4.38 4.10 4.04 4.02 4.54 4.25 4.18 4.16
86
83
80
77
74
71
68
23.8 31.3 36.5 34.1 26.1 34.2 37.7 35.2 28.5 37.0 38.8 36.3 30.5 39.4 39.3 36.8 32.6 41.9 39.8 37.2
20.8 28.3 34.6 34.1 22.6 30.6 36.7 35.2 24.4 32.9 38.8 36.3 25.9 34.8 39.3 36.8 27.3 36.6 39.8 37.2
17.8 25.4 31.6 31.9 19.1 27.1 33.8 34.1 20.3 28.8 36.0 36.3 21.2 30.1 37.6 36.8 22.1 31.4 39.2 37.2
14.9 22.4 28.6 28.9 15.5 23.6 30.3 30.6 16.2 24.7 31.9 32.2 16.6 25.5 32.9 32.1 16.9 26.2 34.0 32.0
11.9 19.4 25.6 26.0 12.0 20.0 26.7 27.0 12.1 20.7 27.8 28.1 11.9 20.8 28.3 27.5 11.7 21.0 28.8 26.8
85 °F
-
-
16.4 22.7 23.0
13.4 19.7 20.0
-
-
16.5 23.2 23.5
12.9 19.6 20.0
-
-
16.6 23.7 24.1
12.5 19.6 20.0
-
-
16.2 23.6 22.8
11.5 19.0 18.2
-
-
15.8 23.6 21.6
10.6 18.3 16.4
Net Cap
MBH
Total Power
Input kW
38.7 36.7 34.0 32.7 40.1 38.1 35.2 33.9 41.6 39.4 36.5 35.2 42.1 39.9 36.9 35.6 42.6 40.3 37.4 36.0
4.16 4.06 3.96 3.98 4.23 4.13 4.03 4.05 4.30 4.19 4.10 4.11 4.44 4.33 4.23 4.25 4.59 4.47 4.37 4.39
86
83
80
77
74
71
68
23.0 30.4 34.0 32.7 25.4 33.3 35.2 33.9 27.8 36.3 36.5 35.2 29.9 38.3 36.9 35.6 32.0 40.3 37.4 36.0
20.0 27.4 33.2 32.7 21.9 29.8 34.9 33.9 23.7 32.2 36.5 35.2 25.2 34.1 36.9 35.6 26.7 36.0 37.4 36.0
17.0 24.4 30.3 30.4 18.3 26.3 32.6 32.8 19.7 28.2 35.0 35.2 20.6 29.5 36.2 35.6 21.5 30.8 37.4 36.0
14.0 21.4 27.3 27.5 14.8 22.7 29.1 29.3 15.6 24.1 30.9 31.1 15.9 24.8 31.5 30.9 16.3 25.6 32.1 30.8
11.0 18.4 24.3 24.5 11.3 19.2 25.5 25.7 11.5 20.0 26.8 27.0 11.3 20.2 26.9 26.3 11.1 20.4 26.9 25.5
95 °F
-
-
15.4 21.3 21.5
12.4 18.3 18.5
-
-
15.6 22.0 22.2
12.1 18.4 18.7
-
-
15.9 22.7 22.9
11.8 18.6 18.8
-
-
15.5 22.2 21.6
10.9 17.6 17.0
-
-
15.2 21.7 20.3
10.0 16.5 15.1
Net Cap
MBH
Total Power
Input kW
36.2 33.9 30.8 31.2 37.6 35.1 32.0 32.4 38.9 36.4 33.1 33.6 39.4 36.8 33.5 34.0 39.9 37.3 33.9 34.4
4.40 4.28 4.20 4.22 4.47 4.35 4.27 4.29 4.54 4.42 4.34 4.35 4.69 4.57 4.48 4.50 4.84 4.71 4.63 4.64
86
83
80
77
74
71
68
22.4 29.3 30.8 31.2 24.8 32.1 32.0 32.4 27.3 34.9 33.1 33.6 29.3 36.1 33.5 34.0 31.4 37.3 33.9 34.4
19.4 26.3 30.5 31.2 21.3 28.8 31.8 32.4 23.2 31.3 33.1 33.6 24.7 33.2 33.5 34.0 26.2 35.1 33.9 34.4
16.4 23.3 27.8 28.8 17.7 25.3 30.1 31.2 19.1 27.2 32.4 33.6 20.0 28.6 33.1 34.0 21.0 29.9 33.9 34.4
13.4 20.3 24.8 25.8 14.2 21.7 26.5 27.6 15.0 23.1 28.3 29.5 15.4 23.9 28.5 29.3 15.8 24.7 28.7 29.1
10.4 17.3 21.8 22.8 10.7 18.2 23.0 24.1 10.9 19.0 24.2 25.4 10.7 19.3 23.8 24.7 10.6 19.5 23.5 23.9
105 °F
115 °F
125 °F
-
-
14.3 18.8 19.8
11.4 15.8 16.8
-
-
14.7 19.4 20.6
11.1 15.9 17.0
-
-
15.0 20.1 21.3
10.9 16.0 17.2
-
-
14.6 19.2 20.0
10.0 14.5 15.4
-
-
14.3 18.3 18.7
9.1 13.1 13.5
Net Cap
MBH
Total Power
Input kW
33.8 31.1 27.7 29.8 35.0 32.2 28.8 30.9 36.3 33.4 29.8 32.0 36.7 33.8 30.1 32.3 37.2 34.2 30.5 32.7
4.64 4.51 4.44 4.46 4.71 4.58 4.51 4.53 4.78 4.65 4.58 4.59 4.94 4.80 4.73 4.75 5.09 4.96 4.88 4.90
86
83
80
77
74
71
68
21.7 28.3 27.7 29.8 24.2 30.8 28.8 30.9 26.7 33.4 29.8 32.0 28.8 33.8 30.1 32.3 30.9 34.2 30.5 32.7
18.7 25.3 27.7 29.8 20.7 27.8 28.8 30.9 22.6 30.3 29.8 32.0 24.2 32.3 30.1 32.3 25.7 34.2 30.5 32.7
15.7 22.3 25.3 27.1 17.1 24.3 27.5 29.5 18.5 26.3 29.8 32.0 19.5 27.7 30.1 32.3 20.5 29.1 30.5 32.7
12.7 19.3 22.3 24.1 13.6 20.7 24.0 26.0 14.4 22.2 25.7 27.9 14.9 23.0 25.5 27.7 15.3 23.8 25.3 27.5
9.7 16.3 19.3 21.1 10.0 17.2 20.4 22.5 10.3 18.1 21.6 23.8 10.2 18.4 20.8 23.0 10.1 18.6 20.1 22.3
-
-
13.3 16.3 18.1
10.3 13.3 15.2
-
-
13.7 16.9 18.9
10.1 13.4 15.4
-
-
14.0 17.5 19.7
9.9 13.4 15.6
-
-
13.7 16.2 18.4
9.1 11.5 13.7
-
-
13.4 14.8 17.1
8.2 9.6 11.9
Net Cap
MBH
Total Power
Input kW
31.4 28.3 24.6 28.3 32.5 29.3 25.5 29.3 33.6 30.4 26.4 30.3 34.0 30.7 26.7 30.7 34.5 31.1 27.1 31.1
4.9 4.7 4.7 4.7 4.9 4.8 4.7 4.8 5.0 4.9 4.8 4.8 5.2 5.0 5.0 5.0 5.3 5.2 5.1 5.2
86
83
80
77
74
71
68
21.1 27.2 24.6 28.3 23.6 29.6 25.5 29.3 26.1 31.9 26.4 30.3 28.3 31.5 26.7 30.7 30.4 31.1 27.1 31.1
18.1 24.2 25.0 28.3 20.0 26.8 25.7 29.3 22.0 29.4 26.4 30.3 23.6 31.3 26.7 30.7 25.2 33.3 27.1 31.1
15.1 21.3 22.8 25.5 16.5 23.3 25.0 27.9 17.9 25.3 27.2 30.3 19.0 26.7 27.1 30.7 20.0 28.2 27.1 31.1
12.1 18.3 19.8 22.5 13.0 19.7 21.4 24.4 13.9 21.2 23.1 26.3 14.3 22.1 22.5 26.1 14.8 23.0 21.9 25.9
9.1 15.3 16.8 19.5 9.4 16.2 17.9 20.8 9.8 17.1 19.0 22.2 9.7 17.4 17.8 21.4 9.5 17.7 16.6 20.7
-
-
12.3 13.8 16.5
9.3 10.8 13.5
-
-
12.7 14.4 17.3
9.1 10.8 13.8
-
-
13.1 14.9 18.1
9.0 10.8 14.0
-
-
12.8 13.2 16.8
8.1 8.5 12.1
-
-
12.5 11.4 15.5
7.3 6.2 10.2
1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity
ALL SENSIBLE CAPACITIES
10
Johnson Controls Unitary Products
360101-XTG-A-0108
TABLE 8: COOLING CAPACITIES - 4 TON (DEB048)
AIR ON INDOOR COIL
1600 CFM
TEMPERATURE
1200 CFM
1400 CFM
WB °F
1800 CFM
WB °F
2000 CFM
WB °F
OF AIR ON
WB °F
WB °F
OUTDOOR COIL
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
Net Cap
MBH
Total Power
Input kW
49.2 46.1 41.6 41.3 50.6 47.4 42.9 42.5 52.1 48.8 44.1 43.7 52.8 49.4 44.7 44.2 53.4 50.1 45.2 44.8
4.47 4.44 4.35 4.33 4.59 4.57 4.47 4.45 4.72 4.69 4.59 4.57 4.78 4.76 4.66 4.63 4.85 4.83 4.72 4.70
86
83
80
77
74
71
68
28.3 35.7 41.3 41.3 31.5 39.6 42.7 42.5 34.7 43.5 44.1 43.7 37.1 46.3 44.7 44.2 39.5 49.1 45.2 44.8
24.9 32.3 37.8 39.5 27.4 35.6 41.0 41.6 30.0 38.9 44.1 43.7 31.8 41.0 44.7 44.2 33.5 43.2 45.2 44.8
21.4 28.9 34.4 36.1 23.4 31.6 37.6 39.4 25.4 34.2 40.7 42.7 26.5 35.7 42.5 43.8 27.6 37.2 44.3 44.8
18.0 25.5 31.0 32.7 19.4 27.5 33.5 35.4 20.7 29.5 36.1 38.1 21.2 30.4 37.2 38.5 21.6 31.2 38.3 38.9
14.6 22.1 27.6 29.3 15.3 23.5 29.5 31.3 16.0 24.9 31.4 33.4 15.8 25.1 31.9 33.1 15.7 25.3 32.4 32.9
85 °F
-
-
18.6 24.2 25.8
15.2 20.7 22.4
-
-
19.4 25.4 27.3
15.4 21.4 23.2
-
-
20.2 26.7 28.7
15.5 22.1 24.1
-
-
19.8 26.6 27.8
14.4 21.3 22.5
-
-
19.3 26.4 26.9
13.4 20.4 21.0
Net Cap
MBH
Total Power
Input kW
47.2 43.4 39.3 38.8 48.6 44.7 40.5 40.0 50.0 46.0 41.7 41.1 48.9 45.0 40.8 40.2 47.8 44.0 39.9 39.3
4.88 4.85 4.74 4.74 5.00 4.97 4.86 4.86 5.13 5.09 4.98 4.98 5.23 5.20 5.09 5.08 5.34 5.31 5.19 5.19
86
83
80
77
74
71
68
27.7 34.7 39.3 38.8 30.6 38.3 40.5 40.0 33.6 41.9 41.7 41.1 35.3 42.9 40.8 40.2 37.0 44.0 39.9 39.3.
24.2 31.3 36.5 37.9 26.6 34.2 39.1 39.5 28.9 37.2 41.7 41.1 30.0 38.3 40.8 40.2 31.0 39.5 39.9 39.3
20.8 27.9 33.0 34.5 22.5 30.2 35.8 37.4 24.3 32.5 38.5 40.2 24.7 33.0 39.1 39.8 25.0 33.5 39.7 39.3
17.4 24.5 29.6 31.1 18.5 26.2 31.7 33.3 19.6 27.9 33.9 35.6 19.3 27.7 33.8 34.5 19.1 27.6 33.8 33.3
14.0 21.0 26.2 27.7 14.5 22.1 27.7 29.3 14.9 23.2 29.2 30.9 14.0 22.4 28.5 29.1 13.1 21.6 27.8 27.4
95 °F
-
-
17.6 22.8 24.2
14.2 19.4 20.8
-
-
18.1 23.7 25.2
14.0 19.6 21.2
-
-
18.5 24.5 26.2
13.9 19.9 21.6
-
-
17.1 23.2 23.8
11.8 17.9 18.5
-
-
15.7 21.9 21.4
9.7 15.9 15.5
Net Cap
MBH
Total Power
Input kW
45.5 40.1 37.8 37.4 46.1 40.6 38.3 37.9 46.7 41.1 38.8 38.3 46.3 40.8 38.5 38.0 46.0 40.4 38.2 37.7
5.37 5.30 5.21 5.21 5.49 5.43 5.34 5.33 5.62 5.55 5.46 5.45 5.72 5.66 5.56 5.55 5.83 5.76 5.66 5.65
86
83
80
77
74
71
68
27.0 33.2 37.8 37.4 29.6 36.1 38.3 37.9 32.3 39.1 38.8 38.3 34.3 39.7 38.5 38.0 36.4 40.4 38.2 37.7
23.6 29.8 35.7 36.3 25.6 32.2 37.3 37.3 37.6 34.7 38.8 38.3 29.0 36.3 38.5 38.0 30.4 38.0 38.2 37.7
20.1 26.4 32.3 32.9 21.5 28.2 34.6 35.2 22.9 30.0 36.8 37.5 23.7 31.0 37.5 37.6 24.5 32.0 38.1 37.7
16.7 22.9 28.9 29.5 17.5 24.2 30.5 31.2 18.3 25.4 32.1 32.8 18.4 25.7 32.1 32.3 18.5 26.0 32.1 31.8
13.3 19.5 25.5 26.1 13.5 20.1 26.5 27.1 13.6 20.7 27.5 28.2 13.1 20.4 26.8 27.0 12.5 20.1 26.2 25.8
105 °F
115 °F
125 °F
-
-
16.1 22.0 22.7
12.7 18.6 19.2
-
-
16.1 22.4 23.1
12.0 18.4 19.0
-
-
16.0 22.8 23.5
11.6 18.1 18.8
-
-
15.1 21.5 21.7
9.8 16.2 16.4
-
-
14.1 20.2 19.8
8.1 14.3 13.9
Net Cap
MBH
Total Power
Input kW
43.9 36.7 36.3 36.0 43.6 36.5 36.1 35.8 43.3 36.3 35.8 35.5 43.7 36.6 36.2 35.8 44.1 36.9 36.5 36.2
5.86 5.76 5.69 5.67 5.98 5.88 5.81 5.80 6.11 6.01 5.94 5.92 6.22 6.11 6.04 6.02 6.32 6.21 6.14 6.12
86
83
80
77
74
71
68
26.3 31.7 36.3 36.0 28.6 34.0 36.1 35.8 30.9 36.3 35.8 35.5 33.4 36.6 36.2 35.8 35.8 36.9 36.5 36.2
22.9 28.3 35.0 34.8 24.6 30.2 35.4 35.1 26.3 32.2 35.8 35.5 28.1 34.3 36.2 35.8 29.8 36.4 36.5 36.2
19.5 24.8 31.6 31.3 20.5 26.2 33.3 33.1 21.6 27.6 35.1 34.8 22.7 29.0 35.8 35.5 23.9 30.5 36.5 36.2
16.1 21.4 28.2 27.9 16.5 22.2 29.3 29.0 17.0 22.9 30.4 30.1 17.4 23.7 30.4 30.2 17.9 24.5 30.5 30.2
12.6 18.0 24.7 24.5 12.5 18.1 25.2 25.0 12.3 18.2 25.7 25.4 12.1 18.4 25.1 24.8 12.0 18.5 24.5 24.2
-
-
14.6 21.3 21.1
11.1 17.9 17.6
-
-
14.1 21.2 20.9
10.0 17.1 16.9
-
-
13.6 21.1 20.8
8.9 16.4 16.1
-
-
13.1 19.8 19.5
7.8 14.5 14.2
-
-
12.6 18.6 18.3
6.6 12.6 12.3
Net Cap
MBH
Total Power
Input kW
42.2 33.4 34.8 34.6 41.1 32.4 33.8 33.7 40.0 31.4 32.9 32.7 41.1 32.4 33.8 33.7 42.2 33.4 34.8 34.6
6.3 6.2 6.2 6.1 6.5 6.3 6.3 6.3 6.6 6.5 6.4 6.4 6.7 6.6 6.5 6.5 6.8 6.7 6.6 6.6
86
83
80
77
74
71
68
25.6 30.1 34.8 34.6 27.6 31.8 33.8 33.7 29.6 31.4 32.9 32.7 32.4 32.4 33.8 33.7 35.2 33.4 34.8 34.6
22.2 26.7 34.3 33.2 23.6 28.2 33.6 32.9 25.0 29.8 32.9 32.7 27.1 32.3 33.8 33.7 29.3 33.4 34.8 34.6
18.8 23.3 30.8 29.8 19.5 24.2 32.1 30.9 20.3 25.1 32.9 32.1 21.8 27.0 33.8 33.3 23.3 28.9 34.8 34.6
15.4 19.9 27.4 26.3 15.5 20.2 28.0 26.9 15.6 20.4 28.6 27.4 16.5 21.7 28.8 28.0 17.3 22.9 28.9 28.6
12.0 16.5 24.0 22.9 11.5 16.1 24.0 22.8 11.0 15.8 24.0 22.7 11.2 16.4 23.4 22.7 11.4 17.0 22.9 22.7
-
-
13.0 20.6 19.5
9.6 17.2 16.1
-
-
12.1 19.9 18.8
8.0 15.9 14.7
-
-
11.1 19.3 18.1
6.4 14.6 13.4
-
-
11.1 18.1 17.4
5.7 12.8 12.1
-
-
11.0 17.0 16.7
5.1 11.0 10.7
1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity
ALL SENSIBLE CAPACITIES
Johnson Controls Unitary Products
11
360101-XTG-A-0108
TABLE 9: COOLING CAPACITIES - 5 TON (DEB060)
AIR ON INDOOR COIL
1600 CFM
TEMPERATURE
1200 CFM
1400 CFM
WB °F
1800 CFM
WB °F
2000 CFM
WB °F
OF AIR ON
WB °F
WB °F
OUTDOOR COIL
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
Net Cap
MBH
Total Power
Input kW
65.2 59.2 52.9 53.4 67.2 61.1 54.5 55.1 69.2 62.9 56.2 56.7 70.3 63.9 57.1 57.6 71.4 64.9 58.0 58.6
5.68 5.60 4.45 5.41 5.87 5.79 5.63 5.59 6.06 5.98 5.82 5.77 6.25 6.16 6.00 5.95 6.43 6.35 6.18 6.13
86
83
80
77
74
71
68
37.9 46.9 52.9 53.4 41.7 51.4 54.5 55.1 45.6 56.0 56.2 56.7 49.1 60.1 57.1 57.6 52.6 64.2 58.0 58.6
33.6 42.6 50.2 51.9 36.7 46.4 53.2 54.3 39.8 50.1 56.2 56.7 42.5 53.4 57.1 57.6 45.2 56.7 58.0 58.6
29.3 38.3 45.9 47.6 31.6 41.3 49.5 51.3 33.9 44.3 53.1 55.0 35.8 46.8 55.6 56.8 37.7 49.3 58.0 58.6
25.1 34.0 41.7 43.3 26.6 36.3 44.5 46.2 28.1 38.5 47.3 49.2 29.2 40.2 48.9 50.2 30.3 41.8 50.6 51.1
20.8 29.8 37.4 39.0 21.5 31.2 39.4 41.2 22.3 32.7 41.5 43.4 22.5 33.5 42.3 43.5 22.8 34.4 43.1 43.7
85 °F
-
-
25.5 33.1 34.7
21.2 28.8 30.5
-
-
26.2 34.4 36.1
21.1 29.3 31.1
-
-
26.8 35.6 37.5
21.0 29.8 31.7
-
-
26.9 35.6 36.9
20.2 29.0 30.2
-
-
26.9 35.7 36.2
19.5 28.2 28.8
Net Cap
MBH
Total Power
Input kW
60.1 54.7 48.7 49.4 62.5 56.9 50.7 51.3 64.9 59.1 52.6 53.3 65.7 59.9 53.3 54.0 66.5 60.6 53.9 54.6
6.25 6.13 6.02 5.97 6.42 6.30 6.19 6.13 6.59 6.47 6.35 6.30 6.78 6.66 6.54 6.48 6.97 6.84 6.72 6.66
86
83
80
77
74
71
68
35.5 44.5 48.7 49.4 39.4 49.2 50.7 51.3 43.3 53.9 52.6 53.3 47.0 57.2 53.3 54.0 50.8 60.6 53.9 54.6
31.2 40.2 47.6 48.7 34.4 44.1 50.1 51.0 37.5 48.0 52.6 53.3 40.4 51.7 53.3 54.0 43.3 55.3 53.9 54.6
27.0 35.9 43.3 44.4 39.3 39.1 47.1 48.2 31.7 42.2 50.9 52.1 33.8 45.0 52.4 53.4 35.9 47.8 53.9 54.6
22.7 31.7 39.0 40.1 24.3 34.0 42.0 43.2 25.8 36.4 45.0 46.3 27.1 38.4 45.7 46.7 28.4 40.4 46.4 47.2
18.4 27.4 34.8 35.8 19.2 29.0 37.0 38.1 20.0 30.5 39.2 40.4 20.5 31.7 39.1 40.1 21.0 32.9 39.0 39.7
95 °F
-
-
23.1 30.5 31.5
18.8 26.2 27.3
-
-
23.9 31.9 33.1
18.9 26.9 28.0
-
-
24.7 33.4 34.6
18.9 27.5 28.8
-
-
25.1 32.5 33.4
18.4 25.8 26.8
-
-
25.5 31.5 32.3
18.0 24.1 24.8
Net Cap
MBH
Total Power
Input kW
55.5 50.2 45.0 45.3 57.9 52.3 46.9 47.2 60.2 54.4 48.8 49.1 60.9 55.0 49.3 49.7 61.6 55.6 49.9 50.2
6.90 6.73 6.63 6.58 7.07 6.90 6.79 6.75 7.25 7.06 6.96 6.91 7.47 7.28 7.17 7.12 7.69 7.50 7.38 7.33
86
83
80
77
74
71
68
33.5 42.4 45.0 45.3 37.5 47.1 46.9 47.2 41.4 51.8 48.8 49.1 44.9 53.7 49.3 49.7 48.3 55.6 49.9 50.2
29.2 38.1 44.0 44.5 32.4 42.2 46.4 46.8 35.6 46.3 48.8 49.1 38.2 49.5 49.3 49.7 40.8 52.8 49.9 50.2
24.9 33.8 39.8 40.2 27.4 37.1 43.6 44.2 29.8 40.5 47.5 48.1 31.6 42.9 48.7 49.2 33.4 45.3 49.9 50.2
20.6 29.6 35.5 36.0 22.3 32.1 38.6 39.1 24.0 34.6 41.7 42.3 24.9 36.3 42.1 42.5 25.9 37.9 42.4 42.8
16.4 25.3 31.2 31.7 17.2 27.0 33.5 34.1 18.1 28.8 35.9 36.4 18.3 29.6 35.4 35.9 18.5 30.4 35.0 35.3
105 °F
115 °F
125 °F
-
-
21.0 26.9 27.4
16.7 22.7 23.1
-
-
22.0 28.5 29.0
16.9 23.4 23.9
-
-
23.0 30.0 30.6
17.1 24.2 24.8
-
-
23.0 28.8 29.2
16.3 22.1 22.6
-
-
23.0 27.5 27.9
15.5 20.1 20.4
Net Cap
MBH
Total Power
Input kW
51.0 45.7 41.3 41.3 53.2 47.6 43.1 43.1 55.5 49.6 45.0 44.9 56.0 50.2 45.4 45.4 56.6 50.7 45.9 45.8
7.56 7.33 7.23 7.20 7.73 7.50 7.39 7.36 7.90 7.66 7.56 7.52 8.15 7.90 7.80 7.76 8.40 8.15 8.04 8.00
86
83
80
77
74
71
68
31.4 40.3 41.3 41.3 35.5 45.0 43.1 43.1 39.6 49.6 45.0 44.9 42.7 50.2 45.4 45.4 45.8 50.7 45.9 45.8
27.2 36.0 40.5 40.4 30.5 40.3 42.7 42.7 33.7 44.5 45.0 44.9 36.1 47.4 45.4 45.4 38.4 50.3 45.9 45.8
22.9 31.7 36.2 36.1 25.4 35.2 40.2 40.1 27.9 38.7 44.2 44.1 29.4 40.8 45.0 45.0 30.9 42.9 45.9 45.8
18.6 27.5 32.0 31.8 20.3 30.2 35.2 35.0 22.1 32.9 38.4 38.2 22.8 34.1 38.4 38.3 23.5 35.4 38.4 38.4
14.3 23.2 27.7 27.6 15.3 25.1 30.1 30.0 16.2 27.0 32.5 32.4 16.1 27.5 31.8 31.7 16.0 27.9 31.0 30.9
-
-
18.9 23.4 23.3
14.6 19.1 19.0
-
-
20.1 25.0 24.9
15.0 20.0 19.9
-
-
21.2 26.7 26.6
15.4 20.9 20.7
-
-
20.9 25.1 25.0
14.2 18.5 18.4
-
-
20.5 23.5 23.5
13.0 16.1 16.0
Net Cap
MBH
Total Power
Input kW
46.5 41.1 37.7 37.3 48.6 43.0 39.4 39.0 50.7 44.9 41.1 40.7 51.2 45.3 41.5 41.1 51.7 45.7 41.9 41.5
8.2 7.9 7.8 7.8 8.4 8.1 8.0 8.0 8.5 8.3 8.2 8.1 8.8 8.5 8.4 8.4 9.1 8.8 8.7 8.7
86
83
80
77
74
71
68
29.4 38.2 37.7 37.3 33.6 42.9 39.4 39.0 37.7 44.9 41.1 40.7 40.5 45.3 41.5 41.1 43.3 45.7 41.9 41.5
25.1 33.9 37.0 36.3 28.5 38.3 39.0 38.5 31.9 42.8 41.1 40.7 33.9 45.3 41.5 41.1 35.9 45.7 41.9 41.5
20.8 29.6 32.7 32.0 23.4 33.3 36.8 36.0 26.0 36.9 40.9 40.0 27.2 38.7 41.4 40.7 28.4 40.4 41.9 41.5
16.6 25.3 28.4 27.7 18.4 28.2 31.7 31.0 20.2 31.1 35.0 34.2 20.6 32.0 34.7 34.1 21.0 32.9 34.4 34.0
12.3 21.1 24.1 23.4 13.3 23.2 26.7 25.9 14.4 25.3 29.2 28.4 14.0 25.4 28.1 27.5 13.5 25.5 27.0 26.6
-
-
16.8 19.9 19.2
12.5 15.6 14.9
-
-
18.1 21.6 20.8
13.1 16.6 15.8
-
-
19.5 23.4 22.5
13.6 17.5 16.7
-
-
18.7 21.5 20.8
12.1 14.8 14.2
-
-
18.0 19.5 19.1
10.6 12.1 11.7
1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity
ALL SENSIBLE CAPACITIES
12
Johnson Controls Unitary Products
360101-XTG-A-0108
TABLE 10: SIDE AND BOTTOM SUPPLY AIR BLOWER PERFORMANCE
Blower
Speed
Setting CFM
High
Medium
Low
High
Medium
Low
External Static Pressure (Inches Water Gauge)
0.4 0.5 0.6 0.7 0.8
CFM CFM CFM CFM CFM
Model No.
DEB
0.1
0.2
CFM
-
0.3
CFM
-
0.9
CFM
-
-
-
1.0
CFM
-
-
-
1.1
CFM
W
-
-
W
-
-
W
-
-
W
W
W
W
W
-
-
W
-
-
W
-
-
W
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
689 374 593 361 497 347
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
018
(1.5)
-
-
690 231 659 210 487 188
741 226 686 212 632 198 577 185 453 165
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
990 468 888 456 786 444 684 432
024
(2.0)
961 331 902 321 841 305 781 290 720 274 660 257
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
810 261 765 250 720 238 675 227 627 212
-
-
-
-
-
-
High
-
-
-
-
-
-
-
-
1171 504 1080 486 990 468 888 456 786 444
030
(2.5)
Medium 1080 351 1021 341 961 331 902 321 841 305 781 290
Low
High
Medium 1465 531 1395 512 1325 492 1255 473 1167 446 1079 419 992 392
Low
High
Medium
Low
-
-
-
-
-
-
-
-
-
-
-
-
810 261 765 240
-
-
-
-
-
-
-
-
-
-
-
-
1440 605 1361 581 1273 555 1185 530 1097 504 1004 480 912 456
036
(3.0)
-
-
-
-
-
-
-
-
1316 473 1260 455 1204 438 1148 420 1069 396 990 372 911 348
-
-
-
-
-
-
1728 725 1633 697 1527 666 1422 635 1317 605 1205 576 1094 547
1674 614 1590 590 1506 567 1400 535 1295 502 1190 470 1063 428
042
(3.5)
-
-
-
-
1579 567 1512 546 1444 525 1377 504 1282 476 1188 447 1093 418
-
-
High
-
-
1985 870 1939 850 1897 830 1813 800 1728 770 1644 740 1559 707 1474 673 1389 640
048
(4.0)
Medium 1694 690 1662 673 1629 657 1597 640 1542 623 1486 607 1431 590 1336 563 1240 537
Low
High
Medium 2339 1170 2275 1118 2211 1067 2147 1015 2083 963 2019 912 1955 860 1854 824 1753 788 1652 752
Low 1929 940 1877 903 1824 867 1772 830 1720 793 1667 757 1615 720 1586 706 1557 691 1528 677
-
-
-
-
-
-
-
-
1385 520 1349 510 1312 500 1276 490 1235 480
-
-
-
-
-
-
-
-
-
-
-
-
2450 1213 2366 1165 2282 1117 2198 1068 2114 1020 1989 993 1864 967 1739 940
060
(5.0)
-
TABLE 11: ADDITIONAL STATIC RESISTANCE
Resistance, IWG
CFM
Description
500
.01
.00
.01
.02
600
.01
.00
.02
.03
700
.01
.00
.02
.03
800
.02
.01
.02
.03
900
.03
.01
.02
.04
1,000
.04
1,100
.05
1,200
.06
1,300
.07
1,400
.08
1,500
.09
1,600
.09
Wet Evaporator Coil
Economizer
.01
.01
.02
.03
.04
.05
.06
Filter/Frame Kit
Electric Heat
.02
.03
.03
.03
.03
.04
.05
.04
.05
.06
.07
.08
.09
.10
Note:1. Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table.
2. The pressure thru the economizer is greater for 100% outdoor air then for 100% return air. If the resistance of the return air duct
system is less then 0.25 IWG, the unit will deliver less CFM during full economizer operation.
THERMOSTAT
UNIT TERMINAL STRIP
**
CAUTION: Label all wires prior to discon-
nection when servicing con-
** = Minimum wire size of 18 AWG
trols. Wiring errors can cause
wire should be used for all field
installed 24 volt wire.
24 VOLT
TRANSFORMER
improper and dangerous op-
eration. Verify proper operation
after servicing.
PROGRAMMABLE
THERMOSTAT ONLY
*
NOTE:
HEAT ANTICIPATOR
SHOULD BE SET AT 0.25
AMPS FOR ALL MODELS.
* = Only required on units with
supplemental electric heat.
CONTROL WIRING
REFER TO ELECTRICAL
DATA TABLES TO SIZE
THE DISCONNECT
POWER WIRING
FIGURE 2 - TYPICAL FIELD WIRING DIAGRAM
Johnson Controls Unitary Products
13
360101-XTG-A-0108
TABLE 12: ELECTRICAL DATA (BASIC UNIT)
Cond. Supply Air
Max
Max HACR/
Breaker
Size
Voltage
Limitations
Unit
Power
Factory
Transformer
Size
Compressors
Fan
Motors
Blower
Motor
Model
DEB
MCA
(Amps)
Fuse
1
Volt
2
Size
(VA)
(Amps)
(Amps)
Min. Max.
RLA
9.0
LRA
48.0
60.0
73.0
94.0
86.0
140.0
165.0
FLA
1.1
1.1
1.1
1.1
1.1
1.3
1.3
FLA
2.6
2.6
2.6
3.5
3.5
4.0
4.0
018
024
030
036
042
048
060
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
187
187
187
187
187
187
187
253
253
253
253
253
253
253
14.9
18.1
22.1
26.2
23.9
35.8
44.4
20
20
25
30
35
30
45
60
.96
.96
.96
.96
.96
.96
.96
40
40
40
40
40
40
40
11.5
14.7
17.3
15.5
24.4
28.9
25
30
35
30
45
60
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element, time delay type
KW CAP.
MULTIPLIER
.75
NOMINAL VOLTAGE
VOLTAGE
ELECTRIC HEAT
CORRECTION
FACTORS
208
230
240
.92
TABLE 13: ELECTRICAL DATA (COOLING/ELECTRIC HEAT)
Compressor
ELECTRIC HEAT ACCESSORY
Max.
HACR
Breaker
Size
(Amps)
Cond..
Fan
Motor
FLA
Supply
Air Blower
Motor
Min.
Max.
Fuse
SizE
2
Model
DEB
Power
Supply
Circuit
Ampacity
(Amps)
Total
AMPS
1
RLA
LRA
48.0
60.0
Model No.
Stage
KW
FLA
(Amps)
2NH04500506
2NH04500706
2NH04500506
2NH04500706
2NH04501006
2NH04500506
2NH04500706
2NH04501006
2NH04501506
2NH04501006
2NH04501506
2NH04500506
2NH04500706
2NH04501006
2NH04501506
2NH04501006
2NH04501506
2NH04502006
2NH04502506
2NH04501006
2NH04501506
2NH04502006
2NH04502506
1
2
1
2
2
1
2
2
2
2
2
1
2
2
2
2
2
2
2
2
2
2
2
3.8/5.0* 18.1/20.8 25.8/29.3 30/30
5.6/7.5* 27.1/31.3 37.1/42.3 40/45
3.8/5.0* 18.1/20.8 25.8/29.3 30/30
5.6/7.5* 27.1/31.3 37.1/42.3 40/45
7.5/10.0* 36.1/41.7 48.4/55.3 50/60
3.8/5.0* 18.1/20.8 25.8/29.3 30/30
5.6/7.5* 27.3/31.3 37.1/42.3 40/45
7.5/10.0* 36.1/41.7 48.4/55.3 50/60
11.3/15.0* 54.2/62.5 71.0/81.4 80/90
7.5/10.0* 36.1/41.7 49.5/56.5 50/60
11.3/15.0* 54.2/62.5 72.1/82.5 80/90
3.8/5.0* 18.1/20.8 26.9/30.4 35/35
5.6/7.5* 27.1/31.3 38.2/43.4 40/45
7.5/10.0* 36.1/41.7 49.5/56.5 50/60
11.3/15.0* 54.2/62.5 72.1/82.5 80/90
7.5/10.0* 36.1/41.7 50.1/57.1 60/60
11.3/15.0* 54.2/62.5 72.1/83.1 80/90
30/30
40/45
30/30
40/45
50/60
30/30
40/45
50/60
80/90
50/60
80/90
35/35
40/45
50/60
80/90
60/60
80/90
018 208/230-1-60 9.0
024 208/230-1-60 11.2
1.1
1.1
2.6
2.6
030 208/230-1-60 12.0
036 208/230-1-60 17.3
042 208/230-1-60 15.5
73.0
94.0
86.0
1.1
1.1
1.1
2.6
3.5
3.5
048 208/230-1-60 24.4
060 208/230-1-60 28.9
140.0
165.0
1.3
1.3
4.0
7.0
15.0/20.0* 72.2/83.3 95.3/109.2 100/110 100/110
18.8/25.0* 90.3/104.2 117.8/135.2 125/150 125/150
7.5/10.0* 36.1/41.7 53.9/60.8 70/70
11.3/15.0* 54.2/62.5 76.5/86.9 80/90
70/70
80/90
15.0/20.0* 72.2/83.3 99.0/112.9 100/125 100/125
18.8/25.0* 90.3/104.2 121.6/139.0 125/150 125/150
1. Dual element, time delay type.
2. Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused.
KW listed is for 240 volts, use table at top of page for 208 or 230 volts.
*
14
Johnson Controls Unitary Products
360101-XTG-A-0108
HIGH VOLTAGE CONN.
" DIA. KNOCKOUT
FRONT
“A”
COMPRESSOR
SERVICE ACCESS
HIGH VOLTAGE CONN.
" DIA. KNOCKOUT
COMPARTMENT PANEL
DIMENSION
LOW VOLTAGE CONN.
“ DIA. KNOCKOUT
UNIT SIZE
“A”
(OVERALL)
2
018 - 042
048 - 060
33
41
SIDE SUPPLY
AIR OPENING
REFRIGERANT
CONNECTIONS
SIDE RETURN
AIR OPENING
ELECTRICAL/FILTER
SERVICE ACCESS
COMPARTMENT PANEL
HIGH VOLTAGE CONN.
" DIA. KNOCKOUT
(OVERALL)
2
(OVERALL)
1
LOW VOLTAGE CONN.
“ DIA. KNOCKOUT
UNIT CONDENSATE
CONNECTION “ NPTI
(TRAP REQUIRED)
4
FRONT
All dimensions are in inches. They are
subject to change without notice. Certified
dimensions will be provided upon request.
HIGH VOLTAGE
CONN. “ x " DIA.
KNOCKOUT
SIDE SUPPLY
AIR OPENING
BACK
CONDENSER
COIL
6
SIDE RETURN
AIR OPENING
CONDENSATE
DRAIN “ NPTI
BOTTOM SUPPLY
AIR OPENING
2
1
CLEARANCES
(Minimum)
Front
Back
12"
0"
15
15
4
Left Side (Filter Access) 24"
1
15
Right Side
24"
0"
Below Unit 1
BOTTOM RETURN
AIR OPENING
36" (For Condenser
Above Unit 2
Air Discharge)
1
1 Units may be installed on combustible floors made from wood or class A,
B or C roof covering material.
2 Units must be installed outdoors. Overhanging structures or shrubs
should not obstruct outdoor air discharge outlet.
FIGURE 3 - UNIT DIMENSIONS
Johnson Controls Unitary Products
15
360101-XTG-A-0108
TABLE 14: UNIT WEIGHTS
Corner Weights
Shipping
Unit Size
Operating
Weight
Economizer
Roof Curb
(lbs.)
Weight
(lbs.)
A
86
88
85
91
94
92
105
B
76
77
81
80
83
88
100
C
D
018
024
030
036
042
048
060
318
324
333
338
347
368
376
313
319
328
333
342
363
371
73
75
82
78
80
92
84
83
85
86
88
91
97
87
8" - 70
14" - 75
40
CENTER OF GRAVITY
D
B
C
FRONT
A
OF
UNIT
26
FIGURE 4 - CENTER OF GRAVITY
16
Johnson Controls Unitary Products
360101-XTG-A-0108
TYPICAL APPLICATIONS
SUPPLY AIR
DUCT
RETURN AIR
DUCT
FIELD SUPPLIED
DISCONNECT SWITCH
LOCATED TO REAR OF UNIT
TO POWER SUPPLY
CONTROL WIRING
TO INDOOR
THERMOSTAT
FIGURE 5 - TYPICAL SLAB ON GROUND INSTALLATION
FIELD SUPPLIED
DISCONNECT SWITCH
MOUNTED ON UNIT
TO POWER SUPPLY
CONTROL WIRING
TO INDOOR THERMOSTAT
SUPPLY AIR
DUCT
ROOF CURB
INSTALLATION
ROOF CURB
REAR DUCT
RETURN AIR
DUCT
INSTALLATION
BOTTOM DUCT
SLAB ON GROUND
INSTALLATION
FIGURE 6 - TYPICAL ROOF CURB INSTALLATION
Johnson Controls Unitary Products
17
360101-XTG-A-0108
1
4
OPENING FOR
RETURN AIR DUCT
22
OPENING FOR
SUPPLY AIR DUCT
1
14
FRONT
WOOD NAILER
INSULATED
PANELS
RECOMMENDED DUCT SIZE
SUPPLY AIR DUCT
RETURN AIR DUCT
" x
" x
"
"
FIGURE 7 - ROOF CURB DIMENSIONS (8” Roof curb also available)
1"
" x 1" WIDE GASKETING FOR CURB FRAME
AND ALL DUCT SUPPORT SURFACES
UNIT BASE RAIL
COUNTERFLASHING
CANT STRIP
UNIT BASE
WOOD NAILER
8" MIN. ABOVE FINISHED ROOF
14"
INSULATION AND ROOFING MATERIAL
CURB FRAME
INSULATION
ROOF DECK AND ROOFING MATERIAL
FIGURE 8 - ROOF CURB APPLICATION
18
Johnson Controls Unitary Products
360101-XTG-A-0108
SEE
DETAIL
"A"
OPTIONAL CCH
S / P CONFIGURATION
CCH
BLK
BLK
L1
T1
D / P CONFIGURATION
CCH
BLK
L1
BLK
2
L
M1 - 2
L2
T2
DETAIL "A"
15695BASH0301
FIGURE 9 - TYPICAL WIRING DIAGRAM (208/230-1-60 POWER SUPPLY) DEB MODELS
Johnson Controls Unitary Products
19
360101-XTG-A-0108
INDOOR (EVAPORATOR) FAN ASSEMBLY
MECHANICAL SPECIFICATIONS
1. Fan shall be direct drive, multi-speed design. Job site
selected (BHP) brake horse power shall not exceed the
motors nameplate horse power rating.
GENERAL DESCRIPTION
Units shall be factory-assembled, single packaged, Electric
Cooling units, designed for outdoor mounted installation. They
shall have built in, equal size, field convertible duct connections
for down discharge supply/return or horizontal discharge
supply/return.
2. Fan wheel shall be double-inlet type with forward-curved
blades, dynamically balanced to operate smoothly
throughout the entire range of operation. Airflow design
shall be constant air volume.
3. Bearings shall be sealed and permanently lubricated for
longer life and no maintenance.
The units shall be factory wired, piped, charged with R-22
refrigerant and factory tested prior to shipment. All unit wiring
shall be both numbered and color coded.
4. Fan assembly shall be “Slip Track” (slide-out) design for
easy removal and cleaning.
All units shall be manufactured in a facility certified to ISO 9001
standards, and the cooling performance shall be tested in
accordance with ARI test procedures. Units shall be certified to
UL 1995/CAN/CSA C22.2 No. 236 standards.
OUTDOOR (CONDENSER) FAN ASSEMBLY
1. The outdoor fan shall be of the direct-driven propeller type,
discharge air vertically, have aluminum blades riveted to
corrosion resistant steel spider bracket and shall be
statically balanced for smooth operation.
UNIT CABINET
1. Unit cabinet shall be constructed of a combination of G60
and G90 galvanized steel, with exterior surfaces coated
with a non-chalking, powdered paint finish, certified at
750 hours salt spray test per ASTMB117 standards.
2. The outdoor fan motor shall be totally enclosed with
permanently lubricated bearings and internally protected
against overload conditions.
2. The unit top shall be a single piece “Water Shed” design,
with drip edges and no-seam corners to provide optimum
water integrity
REFRIGERANT COMPONENTS
1. Compressors:
3. Unit shall have a rigidly mounted condenser coil guard to
provide protection from objects and personnel after
installation.
a. Shall be fully hermetic reciprocating type, direct drive,
internally protected with internal high-pressure relief and
over temperature protection. The hermetic motor shall be
suction gas cooled and have a voltage range of + or -
10% of the unit nameplate voltage.
4. Indoor blower section shall be insulated with up to 3/4”
thick, aluminum, foil faced insulation, fastened to prevent
insulation from entering the air stream.
b Shall have internal isolation and sound muffling to
minimize vibration and noise, and be externally isolated
on a dedicated, independent mounting.
5. Cabinet panels shall be “large” size, easily removable for
servicing and maintenance, with built-in lift handles.
6. Unit shall be built on a formed, “Super-Structure” design
base pan, with embossments at critical points to add
strength, rigidity and aid in minimizing sound.
2. Coils:
a. Evaporator and condenser coils shall have aluminum
plate fins mechanically bonded to seamless internally-
enhanced copper tubes with all joints brazed.
7. Full perimeter base rails shall be provided to assure
reliable transit of equipment, overhead rigging, fork truck
access and proper sealing on roof curb applications. Base
rails shall be removable, when required, to lower unit
height.
b Evaporator and Condenser coils shall be of the direct
expansion, draw-thru design.
3. Refrigerant Circuit and Refrigerant Safety Components
shall include:
8. Filters shall be furnished and be accessible through a
removable access door, sealed air tight. (Single phase
models - accessory kit available. Three phase models -
standard from factory.)
a. Independent fixed-orifice expansion devices.
b. Filter/strainer to eliminate any foreign matter.
c. Accessible service gauge connections on both suction
and discharge lines to charge, evacuate, and measure
refrigerant pressure during any necessary servicing or
troubleshooting, without losing charge and without
disrupting condenser or evaporator air flow.
9. Units vertical discharge and return duct configuration shall
be designed to fit between standard 24” O.C. beams
without modification to building structure, duct work and
base unit.
10. Condensate pan shall be internally sloped and conform to
ASHRAE 62-89 self-draining standards, with 3/4” NPTI
copper, ridged mount connection.
d The refrigeration system shall provide at least 10° F of
liquid sub-cooling at design conditions.
20
Johnson Controls Unitary Products
360101-XTG-A-0108
4. Unit Controls:
3. The heating section assembly shall slide out of the unit for
easy maintenance and service.
a. Unit shall contain a large, low voltage Terminal Board for
easy connection of field low voltage wiring.
4. Units with electric heating sections shall be wired for a
single point power supply, with branch circuit fusing (where
required).
b. Controls shall be mounted in a large control box with tilt-
out, hinged access door, allowing easy access for trouble
shooting and maintenance without affecting the normal
system operation pressures.
UNIT OPERATING CHARACTERISTICS
1. Unit shall be capable of starting and running at 125° F
outdoor temperature, exceeding maximum load criteria of
ARI Standard 210/240.
c. Unit shall have large, easily removable panels, covering
electrical controls and compressor, allowing easy access
for any necessary maintenance or servicing.
2. The compressor, with standard controls, shall be capable
of operation down to 45° F outdoor temperature. Accessory
low ambient kit shall be available for operation to 0° F.
ELECTRIC HEATING SECTION
1. An electric heating section, with nickel chromium elements,
shall be provided in a range of 5 thru 25 KW, offering two
stages of capacity - 7 KW and above on single phase
heaters, and 20 KW and above on three phase heaters.
ELECTRICAL REQUIREMENTS
All unit power wiring shall enter unit cabinet at a single factory
provided location and be capable of side or bottom entry, to
minimize roof penetrations and avoid unit field modifications.
Separate side and bottom openings shall be provided for the
control wiring.
2. The heating section shall have a primary limit control(s)
and automatic reset, to prevent the heating element
system from operating at an excessive temperature.
Johnson Controls Unitary Products
21
360101-XTG-A-0108
22
Johnson Controls Unitary Products
360101-XTG-A-0108
Johnson Controls Unitary Products
23
Subject to change without notice. Printed in U.S.A.
360101-XTG-A-0108
Copyright © 2008 by Johnson Controls, Inc. All rights reserved.
Supersedes: 263146-XTG-A-0206/036-21753-001-A-0206
Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069
|