Modular
Multi-position
Air Handlers
Air Handler-Convertible
Model: Series 2 Air Handlers 1.5 - 3 ton
GAF2A0A18S11SA
GAF2A0A24S21SA
GAF2A0A30S21SA
GAF2A0A36S31SA
PUB. NO. 22-1858-02
Contents
Features and Benefits
2
4
Optional Equipment
Unique Cabinet Design Features and Benefits 5
General Data
6
6
6
6
6
GAF2A0A18S11SA
GAF2A0A24S21SA
GAF2A0A30S21SA
GAF2A0A36S31SA
Performance Data
Electrical Data
Wiring Diagrams
Field Wiring
7
11
13
14
16
17
Convertibility
Dimensions
Pub. No. 22-1858-02
3
Optional Equipment
OPTIONAL EQUIPMENT FOR GAF2 AIR HANDLERS
Accessory Number
BAYECAA05LG1A
BAYECAA08LG1A
BAYECAA10LG1A
BAYSFSCABAA
Description
Electric Heater, 5kW, Lugs, 24V Control, 1 Ph
Electric Heater, 8kW, Lugs, 24V Control, 1 Ph
Electric Heater, 10kW, Lugs, 24V Control, 1 Ph
Supply Duct Flange A1 1
Fits Cabinet Size
A
A
A
A1 1
A
BAYRETFLGAA
Return Duct Flange A
TASB175SB
Plenum Stand with Sound Baffle A
Front Return Kit
A
BAYFRKIT100
A
BAYBRFBX100
Bottom Return Filter Box
A
BAYWMKIT001
Wall Mount Kit
A
BAYLVKIT100A
Low Voltage Conduit Entry Kit
R-22 TXV Conversion Kit
A
BAYAHTXV1836
A
1 GAF2A0A18-36 Cabinet is one piece 17.5” wide
4
Pub. No. 22-1858-02
Unique Cabinet Design
Features and Benefits
2 Precision Durable
1 Unique Cabinet
Door Seals
Design
5 Conduit
Connection
Location
r Integrated Horizontal
Drain Pans
9 All Aluminum Coil
q Thermal Expansion
Valve (TXV)
3 Refrigeration
7 PSC 3 Speed
Connections
Motor
4 Condensate
Connections
8 VorticaTM Blower
and Deck
e Compact 20.8” Depth
0 Labeled Panels
with Doors Removed
and Connections
w Maximum width
is 17.5”
1 Unique Cabinet Design
9 All Aluminum Coil
- Double wall foamed cabinet system
- Waterproof Cabinet Design
- Integrated Slide Deck for Easy Removal
- Polarized Plug connections on Coil TXV
- Patented Enhanced Coil Fin
- R-4.2 Insulating Value (Avg. Insulating Value R-8)
- Composite Foamed Cabinet Doors
- Sweat Eliminating Cabinet Design
- Loose Fiber Eliminating Design
- Smooth Cleanable Cabinet Design
- 2% or Less air leakage
0 Labeled Panels and Connections
q R-410A Thermal Expansion Valve (TXV)
w Maximum width is 17.5”
e Compact 20.8” Depth with Doors Removed
r Integrated Horizontal Drain Pans
2 Precision Durable Door Seals
3 Brazed Refrigeration Connections
4 Primary/Secondary Condensate Connections
5 Conduit Connection - Conduit Connection on Top
7 PSC 3 Speed Motor
8 VorticaTM Blower and Deck - Polarized Plug on Blower
Pub. No. 22-1858-02
5
General
Data
PRODUCT SPECIFICATIONS
GAF2A0A36S31SA
208-230/1/60
See O.D. Specifications
GAF2A0A18S11SA
208-230/1/60
See O.D. Specifications
GAF2A0A24S21SA
208-230/1/60
GAF2A0A30S21SA
208-230/1/60
MODEL
RATED VOLTS/PH/HZ.
RATINGS 1
INDOOR COIL — Type
Rows — F.P.I.
See O.D. Specifications
See O.D. Specifications
Plate Fin
3 - 14
Plate Fin
3 - 14
Plate Fin
3 - 14
Plate Fin
3 - 14
3.21
3/8
3.21
3/8
3.21
3/8
3.21
3/8
Face Area (sq. ft.)
Tube Size (in.)
TXV
TXV
TXV
TXV
Refrigerant Control
3/4 NPT
See Outline Drawing
3/4 NPT
See Outline Drawing
3/4 NPT
See Outline Drawing
3/4 NPT
See Outline Drawing
Drain Conn. Size (in.)
DUCT CONNECTIONS
INDOOR FAN — Type
Diameter-Width (In.)
No. Used
Drive - No. Speeds
CFM vs. in. w.g.
No. Motors — H.P.
Motor Speed RPM
Volts/Ph/Hz
2
Centrifugal
11 X 8
1
Direct - 3
See Fan Performance Table
1 - 1/2
Centrifugal
11 X 8
1
Direct - 3
See Fan Performance Table
1 - 1/3
Centrifugal
10 X 8
1
Centrifugal
10 X 8
1
Direct - 3
Direct - 3
See Fan Performance Table See Fan Performance Table
1 - 1/4
1075
208-230/1/60
1.3 - 2.6
1 - 1/3
1075
208-230/1/60
1.7 - 3.5
1075
208-230/1/60
2.4 - 3.8
825
208-230/1/60
2.0 - 4.1
F.L. Amps - L.R. Amps
FILTER
No
Throwaway
1 - 16 X 20 - 1 in.
R-410A
No
Throwaway
1 - 16 X 20 - 1 in.
R-410A
No
Throwaway
1 - 16 X 20 - 1 in.
R-410A
No
Throwaway
1 - 16 X 20 - 1 in.
R-410A
Filter Furnished?
Type Recommended
No.-Size-Thickness
REFRIGERANT
Ref. Line Connections
Coupling or Conn. Size — in. Gas
Coupling or Conn. Size — in. Liq.
DIMENSIONS
Brazed
3/4
3/8
Brazed
3/4
3/8
Brazed
3/4
3/8
Brazed
3/4
3/8
H x W x D
40.5 x 20 x 24.5
39.5 x 17.5 x 21.8
H x W x D
40.5 x 20 x 24.5
39.5 x 17.5 x 21.8
H x W x D
40.5 x 20 x 24.5
39.5 x 17.5 x 21.8
H x W x D
40.5 x 20 x 24.5
39.5 x 17.5 x 21.8
Crated (In.)
Uncrated
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
122/112
117/107
120/110
121/111
1 These Air Handlers are AHRI certified with various Split System Air Conditioners
and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor
Unit Product Data Guides for performance data.
2 3/4" Male Plastic Pipe (Ref.: ASTM 1785-76)
6
Pub. No. 22-1858-02
General
Data
GAF2A0A18 AIRFLOW PERFORMANCE TABLE
AIRFLOW PERFORMANCE
GAF2A0A18S11SA
EXTERNAL STATIC
AIRFLOW (CFM)
(in w.g)
Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS
3
2 †
768
741
704
662
607
531
441
346
N/A
N/A
N/A
1
3
2 †
654
636
610
577
529
460
378
244
N/A
N/A
N/A
1
0
952
894
845
785
724
652
557
428
284
N/A
N/A
710
687
658
620
568
494
404
N/A
N/A
N/A
N/A
940
885
831
775
714
640
543
418
225
N/A
N/A
598
581
558
526
477
415
347
N/A
N/A
N/A
N/A
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
NOTES:
1. Values are with wet coil and without filters.
2. Contact your particular filter manufacturer for pressure drop data.
3. Electric heater pressure drop is negligible and is included within the airflow data.
4. † Factory Setting
GAF2A0A18S11SA MINIMUM HEATER AIRFLOW CFM
Heater
Minimum Air Speed Tap
Without Heat Pump
With Heat Pump
Tap 3
BAYECAA05LG1AA
BAYECAA08LG1AA
BAYECAA10LG1AA
Tap 1
Available soon
Available soon
Available soon
Available soon
SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS
Note: Heating and cooling speeds are the same, factory
set at Speed Tap #2.
Pub. No. 22-1858-02
7
Performance
Data
GAF2A0A24 AIRFLOW PERFORMANCE TABLE
AIRFLOW PERFORMANCE
GAF2A0A24S21SA
EXTERNAL STATIC
AIRFLOW (CFM)
Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS
(in w.g)
3
2 †
848
816
784
750
708
659
591
513
416
309
130
1
3
2 †
737
710
683
650
611
547
499
420
339
203
N/A
1
0
998
949
911
869
825
772
707
614
533
413
241
771
745
711
679
638
586
518
444
356
218
N/A
899
868
834
794
756
704
641
555
465
351
167
658
630
602
567
524
476
415
346
268
138
N/A
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
NOTES:
1. Values are with wet coil and without filters.
2. Contact your particular filter manufacturer for pressure drop data.
3. Electric heater pressure drop is negligible and is included within the airflow data.
4. † Factory Setting
GAF2A0A24S21SA MINIMUM HEATER AIRFLOW CFM
Heater
Minimum Air Speed Tap
Without Heat Pump
With Heat Pump
Tap 2
BAYECAA05LG1AA
BAYECAA08LG1AA
BAYECAA10LG1AA
Tap 1
Available soon
Available soon
Available soon
Available soon
SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS
Note: Heating and cooling speeds are the same, factory
set at Speed Tap #2.
8
Pub. No. 22-1858-02
Performance
Data
GAF2A0A30 AIRFLOW PERFORMANCE TABLE
AIRFLOW PERFORMANCE
GAF2A0A30S21SA
EXTERNAL STATIC
(in w.g)
Speed Taps - 230 VOLTS
Speed Taps - 208 VOLTS
3
2 †
1
3
2
1
0
0.1
1052
1012
963
914
865
816
759
690
589
389
179
967
929
888
849
805
759
698
622
503
336
149
932
898
861
823
784
741
681
592
463
318
119
1024
980
934
885
837
788
739
668
559
375
175
877
846
814
777
739
697
640
559
423
285
NA
826
800
771
738
703
663
602
515
395
259
NA
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
NOTES:
1. Values are with wet coil and without filters.
2. Contact your particular filter manufacturer for pressure drop data.
3. Electric heater pressure drop is negligible and is included within the airflow data.
4. † Factory Setting
GAF2A0A30S21SA MINIMUM HEATER AIRFLOW CFM
Heater
Minimum Air Speed Tap
Without Heat Pump
With Heat Pump
Tap 1
BAYECAA05LG1AA
BAYECAA08LG1AA
BAYECAA10LG1AA
Tap 1
Available soon
Available soon
Available soon
Available soon
SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS
Note: Heating and cooling speeds are the same, factory
set at Speed Tap #2.
Pub. No. 22-1858-02
9
Performance
Data
GAF2A0A36 AIRFLOW PERFORMANCE TABLE
AIRFLOW PERFORMANCE
GAF2A0A36S31SA
EXTERNAL STATIC
(in w.g)
Speed Taps - 230 VOLTS
Speed Taps - 208 VOLTS
3
2 †
1
3
2
1
0
1191
1180
1158
1119
1079
1040
993
1146
1132
1110
1082
1045
1005
960
1094
1085
1065
1035
1003
969
1040
1033
1014
979
942
907
864
808
758
696
629
1015
1004
984
958
923
886
843
795
742
675
607
964
959
942
916
887
857
818
772
715
650
583
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
927
934
910
877
880
855
816
815
786
748
744
715
677
NOTES:
1. Values are with wet coil and without filters.
2. Contact your particular filter manufacturer for pressure drop data.
3. Electric heater pressure drop is negligible and is included within the airflow data.
4. † Factory Setting
GAF2A0A36S31SA MINIMUM HEATER AIRFLOW CFM
Heater
Minimum Air Speed Tap
Without Heat Pump
With Heat Pump
Tap 1
BAYECAA05LG1AA
BAYECAA08LG1AA
BAYECAA10LG1AA
Tap 1
Available soon
Available soon
Available soon
Available soon
SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS
Note: Heating and cooling speeds are the same, factory
set at Speed Tap #2.
10
Pub. No. 22-1858-02
Electrical
Data
WIRING DATA
GAF2A0A18S11SA
240 VOLT
208 VOLT
Heater
Model
No.
No.
of
Circuits
Heater
Amps
per
Heater
Amps
per
Minimum
Circuit
Ampacity
Maximum
Overload
Protection
Minimum
Circuit
Ampacity
Maximum
Overload
Protection
Capacity
kW BTUH
Capacity
kW BTUH
Circuit
Circuit
No Heater
-
-
-
2.0**
20
3
15
30
45
60
-
-
2.0**
17.3
27.7
34.6
3
15
25
40
50
BAYECAA05++
BAYECAA08++
BAYECAA10++
1
1
1
4.80
7.68
9.60
16400
26200
32800
28
43
53
3.60
5.76
7.20
12300
19700
24600
24
37
46
32
40
Note: ** Motor Amps
WIRING DATA
GAF2A0A24S21SA
240 VOLT
208 VOLT
Heater
Model
No.
No.
of
Circuits
Heater
Amps
per
Heater
Amps
per
Minimum
Circuit
Ampacity
Maximum
Overload
Protection
Minimum
Circuit
Ampacity
Maximum
Overload
Protection
Capacity
Capacity
kW
-
BTUH
-
kW
-
BTUH
-
Circuit
Circuit
No Heater
-
1.3**
20
2
15
30
45
60
1.3**
17.3
27.7
34.6
2
15
25
40
45
BAYECAA05++
BAYECAA08++
BAYECAA10++
1
1
1
4.80
7.68
9.60
16400
26200
32800
27
42
52
3.60
5.76
7.20
12300
19700
24600
23
38
45
32
40
Note: ** Motor Amps
WIRING DATA
GAF2A0A30S21SA
240 VOLT
208 VOLT
Heater
Model
No.
No.
of
Circuits
Heater
Amps
per
Heater
Amps
per
Minimum
Circuit
Ampacity
Maximum
Overload
Protection
Minimum
Circuit
Ampacity
Maximum
Overload
Protection
Capacity
Capacity
kW
-
BTUH
-
kW
-
BTUH
-
Circuit
Circuit
No Heater
-
1.7**
20
2
15
30
45
60
1.7**
17.3
27.7
34.6
2
15
25
40
45
BAYECAA05++
BAYECAA08++
BAYECAA10++
1
1
1
4.80
7.68
9.60
16400
26200
32800
27
42
52
3.60
5.76
7.20
12300
19700
24600
24
38
45
32
40
Note: ** Motor Amps
Pub. No. 22-1858-02
11
Electrical
Data
WIRING DATA
GAF2A0A36S31SA
240 VOLT
Heater
208 VOLT
Heater
Model
No.
No.
of
Circuits
Heater
Amps
per
Minimum
Circuit
Maximum
Overload
Protection
Minimum
Circuit
Ampacity
Maximum
Overload
Protection
Capacity
kW BTUH
Capacity
kW BTUH
Amps
per
Ampacity
Circuit
Circuit
No Heater
-
-
-
2.4**
20
3
15
30
45
60
-
-
2.4**
17.3
27.7
34.6
3
15
25
40
50
BAYECAA05++
BAYECAA08++
BAYECAA10++
1
1
1
4.80
7.68
9.60
16400
26200
32800
28
43
53
3.60
5.76
7.20
12300
19700
24600
25
38
46
32
40
Note: ** Motor Amps
DISTANCE FROM BELLY BAND TO SHAFT FACE OF MOTOR FOR MINIMUM VIBRATION
BLOWER HOUSING
MODEL
DIM "A"
1-1/8
GAF2A0A18S11SA
GAF2A0A24S21SA
GAF2A0A30S21SA
GAF2A0A36S31SA
BELLY BAND
2-11/16
1-9/16
A
1-11/16
MOTOR
WHEEL
A is determined per chart
Wheel is centered in
Blower Housing
12
Pub. No. 22-1858-02
Pub. No. 22-1858-02
13
Field
Wiring
GAF2 AIR HANDLERS WITH SINGLE SPEED COOLING
Air Handler Hook-up Diagram
Cooling
W1 White
Green
Blue
Air Handler
Air Conditioner
Blue
Comfort Control
White
Green
Yellow
Orange
Red
W
G
Y
O
R
B
White
Green
Yellow
Yellow
Red
Blue
Blue
B - Blue
Y - Yellow
Field wiring
14
Pub. No. 22-1858-02
Field
Wiring
GAF2 AIR HANDLERS WITH SINGLE SPEED HEAT PUMP
Air Handler Hook-up Diagram
HP
Heat Pump
W1 White
Green
Blue
Black
Air Handler
(X2)
Yellow
Comfort Control
Orange
Red
Blue
White
Green
Yellow
W
G
Y
O
R
B
White
Green
Yellow
Orange
Orange
Red
Red
Blue
Blue
R - Red
B - Blue
Y - Yellow
Field wiring
Pub. No. 22-1858-02
15
GAF2
Convertibility
* Note: No internal modifications required for any position.
1 Badge rotation will keep brand in correct position
Multi-position Air Handler
Refrigerant
Connections
Low Voltage
Connections
inside unit
1
Upflow
Condensate
Drains
Upflow Configuration
Low Voltage
Connections
inside unit
Refrigerant
Connections
Refrigerant
Connections
1
Airflow
1
Airflow
Horizontal Right
Condensate
Drains
Horizontal Left
Condensate
Drains
Low Voltage
Connections
inside unit
Horizontal Left*
Horizontal Right*
16
Pub. No. 22-1858-02
Dimensions
GAF2 AIR HANDLER DIMENSIONAL DATA
W
H
D
Model
Number
H x D x W
in.
Unit
Net Weight
lbs.
GAF2A0A18S11SA
GAF2A0A24S21SA
GAF2A0A30S21SA
GAF2A0A36S31SA
39 x 22 x 17.5
39 x 22 x 17.5
39 x 22 x 17.5
39 x 22 x 17.5
107
110
111
112
GAF2 AIR HANDLERS ARE ALL ONE
PIECE CABINETS.
Pub. No. 22-1858-02
17
GAF2 OUTLINE DRAWING
18
Pub. No. 22-1858-02
Pub. No. 22-1858-02
19
11/11
Trane
6200 Troup Highway
Tyler,TX 75707
The manufacturer has a policy of continuous product and product data improvement and it reserves the right
to change design and specifications without notice.
|