Spectralink Ptc400 User Manual

be inserted into the rear slot with the side that attaches to the hand-  
set facing to the rear. See the cover photo for the correct orientation.  
Correct placement has been achieved when the charging light is acti-  
vated. Incorrect placement will not activate the charging light.  
Link Dual Charger  
The Link Dual Charger is a two-slot desktop charger designed to  
charge the model PTS360 Battery Packs. The handset is placed  
in the front compartment and a single spare Battery Pack may be  
placed in the rear slot. Either slot can be chosen to take priority  
(the first Battery Pack placed into either slot is charged first) so  
that the handset is always ready for use. Full charging is accom-  
plished in approximately two hours for each Battery Pack. The  
Link Dual Charger will only charge Nickel Metal Hydride (NiMH)  
Battery Packs; this charger will not charge Nickel-Cadmium (NiCd)  
Battery Packs.  
Operation  
The Link Dual Charger is designed to charge one Battery Pack at a time.  
Each charging slot has a red light that indicates its current mode. The  
charging lights have the following characteristics: When both a Battery  
Pack and a handset are present at the same time, the first one placed  
into the charger will begin charging. When it is fully charged, the second  
Battery Pack will charge. When the LED indicator light turns off, the  
charger is finished charging the Battery Pack in its slot, indicating that  
the Battery Pack is ready for use. The Link Dual Charger will recharge a  
single NiMH Battery Pack or a single handset in two hours.  
Power Supply  
Four different models of the power supply for the Link Dual  
Charger are available for regional power requirements. The cor-  
rect power supply must be ordered separately when the charger  
is ordered. If any questions arise, please contact your service  
representative.  
Removal and Replacement  
To remove the Battery Pack from the handset, slide the Battery Pack  
down and off while pressing the Battery Pack release button on the back  
of the handset. To replace the Battery Pack, align the top of the Battery  
Pack with the arrows on the label on the back of the handset. Gently  
press and slide the pack toward the top of the handset until it snaps in  
place. You should not have to force it against the handset.  
Set up the Link Dual Charger by placing it on a flat, horizontal  
surface in order to ensure proper contact with the Battery Pack  
contacts. Connect the power supply to the charger and plug the  
power supply into an appropriate wall outlet. The LEDs will light  
only when a handset or Battery Pack is inserted into the slots.  
Link Dual Charger PTC400  
For the Link Wireless Telephone  
Cleaning the Link Dual Charger  
Using the Link Dual Charger  
The Link Dual Charger may occasionally need to be cleaned to maintain  
appearance and ensure battery contact. Wipe the surface with a clean,  
water-dampened cloth or paper towel to remove most films or residues.  
If the soiling is too stubborn for plain water, a mild detergent solu-  
tion may be used. Be sure to wipe away any detergent residue with a  
plain water dampened cloth. DO NOT IMMERSE THE LINK DUAL  
CHARGER IN WATER OR OTHER LIQUID. The battery contacts  
may be cleaned with isopropyl (rubbing) alcohol applied with a cotton  
swab, cloth or paper towel. Do not push or pull the exposed battery  
contacts. DO NOT POUR LIQUIDS INTO THE SLOTS.  
The user must end any call in progress by pressing the END key  
on the handset before placing the handset into the charger. The  
call will not automatically terminate when the handset is placed  
in the charger. The Battery Pack and handset will only fit into the  
charger compartments one way. The handset should be inserted  
into the front slot, facing forward. The Battery Pack alone should  
NOTE:  
Indicator Lights  
Chargers operate in a 50° to 85° F (10° to 30° C) environment.  
Do not expose them to freezing temperatures or direct sunlight.  
Indication Light  
Solid On  
Charging Characteristic  
The Link Dual Charger is only authorized for use in the U.S. and  
Canada.  
Charging.  
Solid Dim  
Waiting to charge. Battery Pack in other slot  
is charging.  
Only use the original SpectraLink plug-in power supply.  
Only use SpectraLink Battery Packs in this charger.  
Off  
Done charging, empty slot or unit is not powered.  
It is normal for the Battery Pack to become warm when charging.  
Flash  
Error. Battery Pack not charging. Try again or  
replace Battery Pack.  
Link Dual Charger  
Never use non-SpectraLink charging units as they could damage the  
Battery Pack.  
Do not immerse the Link Dual Charger in water or other liquid. Do  
not pour liquids into the charging slots.  
© 2005 SpectraLink Corporation  
P/N 72-0079-00 Rev. C  
Model # PTC400  
The Link Dual Charger will only successfully charge NiMH Battery  
Packs with a YELLOW label on the handset contact side. Older Battery  
Packs with a GREEN label will not charge in the Link Dual Charger. If  
the indicator light is flashing with a Battery Pack or handset in the slot,  
check to make sure the Battery Pack has a YELLOW label.  
Do not dip the Battery Pack in water or throw into fire.  
Recycle or dispose of Battery Packs according to local requirements.  
SpectraLink Corporation  
5755 Central Avenue  
Boulder, CO 80301  
Replacement Battery Packs are available from your supplier or servic-  
ing agent.  
303.440.5330 or 800.676.5465  

Omega Flowmeter Fl 1500a User Manual
Panasonic Cw Xc120hu User Manual
Panasonic Kx Tg6700al User Manual
Ricoh Fw770 User Manual
Sanyo 24ks72 User Manual
Sanyo Sha Kc64ug User Manual
Savin 3695 User Manual
Sharp Mx 3110n User Manual
Toshiba Lf470 User Manual
Whirlpool Comfort Aire Ra51k0 User Manual