Soleus Air Air Condition User Manual

Please read Owner’s Manual carefully  
before operating the unit.  
Use  
RT-135 series air-condition have the capability of cooling / heating / ventilation and  
dehumidification and contain the character of resisting shake attrition and high-dependability. It  
can be used for applications such as RV units, trucks & vans, small-scale shipping vehicles & farm  
equipment.  
Structure and character  
Structure  
This air conditioning is in the top of structure  
Main components include evaporator, condenser, compressor, throttling device, air blower  
system, protection cover, tunnel and the control panel in main cabin.  
Character  
1) Instant cooling/adjustable temperature: It can reduce the environment temperature in a  
short time in order of passenger’s demand.  
2) Continuously running in adverse condition.  
3) Lengthy continuously running time in acid and alkali condition.  
4) The Width & Height capability : The appearance and assembly size keep the same with  
present products on the market and helps keep air flow fluent.  
5) Quiet operation: Improve comfortableness, low noise.level.  
6) Delay start: With sudden loss of power and rapid reset, compressor is time delayed for 3  
minutes for protection  
Control panel  
2
Remote device  
Operation through the control panel or remote device  
Through the control panel in the room, user can control all functions of the air-conditioner. The  
parts of control contain the following functions:  
1. Switch  
The air-conditioner can be started or stopped by the button “ON/OFF”. The indicator lamp  
“POWER” in the upper left corner is lighted when air-conditioner is running.  
2. Choose button “MODE”  
This button confirms the working status of the air-conditioner.  
You can switch it in:”FAN” state, “COOL” state and “HEAT” state.  
3. Temperature setting button “TEMP”  
Through buttons “” and “”, you can increase and reduce the setting temperature in the  
room.  
4. Fan speed switch button “SPEED”  
You can switch fan speed in “HIGH” or “LOW”.  
5. Temperature showing “temperature”  
In holding state, control panel shows present indoor temperature. The control panel shows  
temperature in setting state. If you don’t press the “TEMP” key more than ten minutes, the  
control panel will be back awaiting state and show present indoor temperature.  
6PushSPEED+MODE(in the control panel) or “SET”(in the remote device) into setting state  
In this state you can set parameter with “” and “”.  
3
The scheme of refrigeration system  
CONDENSER  
EVAPORATOR  
FAN  
COMPRESSOR  
THROTTLE  
4
Schematic circuit diagram  
FU2  
+5V  
GND  
A
B
com  
on  
C
G
DAT  
CLK  
REC  
KEY  
WAT1  
WAT2  
SENSOR1  
SENSOR2  
FU3  
5
Cautions  
1. In any case the compressor will restart 3 minutes after power failure  
2. The air-conditioner adopts three core plugs: Modification will void warranty  
3. Working voltage of the air-conditioner must keep within the range of 115VAC±10. If the  
voltage is too high or low will lead to damage of the compressor.  
4. The normal working environment temperature of the air conditioner is: 0F to115F  
Maintenance and Safeguard  
It will keep at maximum performance ratings if you perform routine maintenance. After running  
for 90 days, you must clean up dust around the fins of the heat exchanger in order to keep  
refrigeration performance at optimum  
TROUBLE SHOOT CHART  
Problem  
Possible Cause  
Solution  
Doesn’t cool / heat  
1. The voltage of the power Adjust the voltage range into  
is lower than 97V  
2. You are using  
normal demand.  
an Do not use an extension cord.  
extension cord for the unit  
3. The system leaks Fluorine Call repair technician  
4. Button “ON/OFF” failure  
Replace button “ON/OFF”.  
5. Set the temperature to the Refer to operation explanation.  
abnormal position.  
6. Compressor not working.  
Turn off for ten minutes. Turn  
back on  
7. The sub cooling of Call repair technician  
compressor is protected  
and does not work  
8. Capillary is blocked  
Call repair technician  
Inadequate cooling  
1. The evaporator and/or Clean the evaporator and  
condenser are blocked by condenser.  
debis .  
2. The doors and windows Reduce times that open the  
have opened frequently.  
3. Heat load is too high.  
door.  
Installation of larger unit.  
4. Set temperature is in Adjust the set value.  
improper position.  
5. Capillary is blocked.  
Call repair technician  
6. The refrigeration system Call repair technician  
has failed.  
6
No heat  
1. Power is off.  
Check the circuit  
2. Set temperature is in Adjust the set value  
improper position  
3. Connector has fallen off.  
4. Heater is defective  
5. Fuse is open.  
Tighten the plug.  
Change the heater.  
Change the fuse.  
6. Control panel is not Change the circuit panel.  
working.  
The fan doesn’t operate  
1. Control panel is faulty.  
Change the panel.  
2. The capacitor of fan Change the capacitor.  
defective.  
3. Fan defective.  
Unusual sound or heavy 1. Installation  
Change the fan.  
the Check Installation.  
too  
of  
shaking  
air-conditioner  
gradient.  
2. Fan touches with other  
hardware.  
Adjust the fan position.  
3. The connective pipelines Adjust the position between  
collide with each other. the pipelines.  
4. The part becomes flexible. Tighten screws.  
Installation  
1. Installation preparation  
If you need to install the air-conditioner on already existing roof vent, the measure of vent  
must reach 14×14 (in). If it is not enough of this measurement, you must extend this  
measurement. If it is larger than this measurement, you must make a wood frame for the vent  
to meet above measurement.  
The gradient of install the platform must no more than 5°. If greater than 5° it can be  
influenced that condensation water of the air conditioner could overflow.  
You must avoid any wire and any pipeline before incision.  
2. Please directly install the top of the air-conditioner on the placket and make windward face  
toward the front of the vehicle, condenser toward the back of the vehicle. Put the seal  
between air-conditioner and placket, and you can sight the four M10 install bores in the  
air-conditioner bottom. To those irregular coarse roofs you must have sealant seal up all gaps  
in order to prevent rainwater infiltrating into room.  
7
3. You must make mounting hole on indoor installation frame align with the hole on the top of  
the air-conditioner and tightly connect with 4-M10 special screw.  
4. Install canvas-pipe  
You must make the flange of the canvas-pipe align with air outlet of the top of air-conditioner  
and connect them with screw, gasket, spring gasket and nut.  
8
5. Prepare installing of indoor equip: Disassemble the indoor equip.  
6.  
Install the indoor unit  
a) You must install the main of indoor tunnel and installation frame with four ST4.2X16  
screw.  
Caution: It can be rotated from +90°to -90°.  
b) Installing the canvas pipe underparts  
You must put into metal flange from canvas pipe under part and tightly nip main vent-pipe  
and connect with ST4.2X16 screw. The surplus part is cut out.  
c) Install covers board of vent-pipe and indoor main cover board.  
d) Connect indoor plastic and gold with two M4×10 screws, gasket and spring gasket.  
9
Check  
1. Check the complete installing manual to make sure unit is installed correctly and safe  
2. Switch on the power, operate the air conditioner according to above methods. If it runs  
improperly, for example abnormal noise, running current too high or no temperature, please check  
owner’s manual.  
10  
3. Clean up the installing rubbish and restore decoration to original decor.  
11  
Warranty  
LIMITED WARRANTY  
Soleus International Inc. warrants the accompanying Soleus Air RT-135 Roof Top Air Conditioner to  
be free of defects in material and workmanship for the applications specified in its operation  
instruction for the period of labor and parts specified below.  
PARTS  
5 YEARS FOR COMPRESSOR  
1 YEAR FOR OTHER COMPONENTS  
This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine  
maintenance. This warranty does not apply to uncrating, setup, installation, removal of the product  
for repair or reinstallation of the product after repair..  
This warranty does not apply to repairs or replacements necessitated by any cause beyond the control  
of Soleus International including, but not limited to, any malfunction, defect or failure caused by or  
resulting from unauthorized service or parts, improper maintenance, operation contrary to furnished  
instructions, shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect,  
accident, incorrect power line voltage, fire, flood or other Acts of God, or normal wear and tear.  
Warranty service must be performed by a qualified HVAC contractor. Soleus maintains a centralized  
service network to provide parts and assist in resolving service problems if difficulties are encountered.  
Soleus agrees to provide service information, sell repair parts and reimburse the dealer / service agent  
for parts and services in accordance with Soleus International’s Policies and Procedures. All labor  
charges must be pre approved in writing.  
SOLEUS INTERNATIONAL MAINTAINS THAT ALL WARRANTIES, INCLUDING  
IMPLIED WARRANTY OR MERCHANTABILITY ARE LIMITED TO THE TERMS AND  
CONDITIONS SPECIFIED ABOVE. SOLEUS INTERNATIONAL DISCLAIMS ANY  
LIBILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT  
SHALL SOLEUS INTERNATIONAL INC.’S LIABILITY EXCEED THE RETAIL VALUE OF  
THE AIR CONDITIONER.  
FOR CUSTOMER SERVICES, WARRANTY CLAIM AND PARTS PURCHASING, CONTACT:  
Soleus International Inc.  
Tel: 1-888-8 Soleus  
Monday through Friday, 9:00 AM to 5:00 PM, PST  
Email:  
12  

Master Lock B150cea User Manual
Mitsubishi Electronics Split Type Heat Pump Air Conditioners Pmfy P12nbmu E1 User Manual
Panasonic 403171 User Manual
Panasonic Hq 2121sh User Manual
Ricoh Fw770 User Manual
Samsung Ast24s6gb User Manual
Sanyo 12khs32 User Manual
Sanyo Cr605gx56 User Manual
Sanyo Khx0752 User Manual
York Sunline 2000 D3cg User Manual