| Please read Owner’s Manual carefully   before operating the unit.   Use   RT-135 series air-condition have the capability of cooling / heating / ventilation and   dehumidification and contain the character of resisting shake attrition and high-dependability. It   can be used for applications such as RV units, trucks & vans, small-scale shipping vehicles & farm   equipment.   Structure and character   Structure   This air conditioning is in the top of structure   Main components include evaporator, condenser, compressor, throttling device, air blower   system, protection cover, tunnel and the control panel in main cabin.   Character   1) Instant cooling/adjustable temperature: It can reduce the environment temperature in a   short time in order of passenger’s demand.   2) Continuously running in adverse condition.   3) Lengthy continuously running time in acid and alkali condition.   4) The Width & Height capability : The appearance and assembly size keep the same with   present products on the market and helps keep air flow fluent.   5) Quiet operation: Improve comfortableness, low noise.level.   6) Delay start: With sudden loss of power and rapid reset, compressor is time delayed for 3   minutes for protection   Control panel   2 Remote device   Operation through the control panel or remote device   Through the control panel in the room, user can control all functions of the air-conditioner. The   parts of control contain the following functions:   1. Switch   The air-conditioner can be started or stopped by the button “ON/OFF”. The indicator lamp   “POWER” in the upper left corner is lighted when air-conditioner is running.   2. Choose button “MODE”   This button confirms the working status of the air-conditioner.   You can switch it in:”FAN” state, “COOL” state and “HEAT” state.   3. Temperature setting button “TEMP”   Through buttons “▲” and “▼”, you can increase and reduce the setting temperature in the   room.   4. Fan speed switch button “SPEED”   You can switch fan speed in “HIGH” or “LOW”.   5. Temperature showing “temperature”   In holding state, control panel shows present indoor temperature. The control panel shows   temperature in setting state. If you don’t press the “TEMP” key more than ten minutes, the   control panel will be back awaiting state and show present indoor temperature.   6. Push“SPEED+MODE”(in the control panel) or “SET”(in the remote device) into setting state   In this state you can set parameter with “▲” and “▼”.   3 The scheme of refrigeration system   CONDENSER   EVAPORATOR   FAN   COMPRESSOR   THROTTLE   4 Schematic circuit diagram   FU2   +5V   GND   A B com   on   C G DAT   CLK   REC   KEY   WAT1   WAT2   SENSOR1   SENSOR2   FU3   5 Cautions   1. In any case the compressor will restart 3 minutes after power failure   2. The air-conditioner adopts three core plugs: Modification will void warranty   3. Working voltage of the air-conditioner must keep within the range of 115VAC±10. If the   voltage is too high or low will lead to damage of the compressor.   4. The normal working environment temperature of the air conditioner is: 0F to115F   Maintenance and Safeguard   It will keep at maximum performance ratings if you perform routine maintenance. After running   for 90 days, you must clean up dust around the fins of the heat exchanger in order to keep   refrigeration performance at optimum   TROUBLE SHOOT CHART   Problem   Possible Cause   Solution   Doesn’t cool / heat   1. The voltage of the power Adjust the voltage range into   is lower than 97V   2. You are using   normal demand.   an Do not use an extension cord.   extension cord for the unit   3. The system leaks Fluorine Call repair technician   4. Button “ON/OFF” failure   Replace button “ON/OFF”.   5. Set the temperature to the Refer to operation explanation.   abnormal position.   6. Compressor not working.   Turn off for ten minutes. Turn   back on   7. The sub cooling of Call repair technician   compressor is protected   and does not work   8. Capillary is blocked   Call repair technician   Inadequate cooling   1. The evaporator and/or Clean the evaporator and   condenser are blocked by condenser.   debis .   2. The doors and windows Reduce times that open the   have opened frequently.   3. Heat load is too high.   door.   Installation of larger unit.   4. Set temperature is in Adjust the set value.   improper position.   5. Capillary is blocked.   Call repair technician   6. The refrigeration system Call repair technician   has failed.   6 No heat   1. Power is off.   Check the circuit   2. Set temperature is in Adjust the set value   improper position   3. Connector has fallen off.   4. Heater is defective   5. Fuse is open.   Tighten the plug.   Change the heater.   Change the fuse.   6. Control panel is not Change the circuit panel.   working.   The fan doesn’t operate   1. Control panel is faulty.   Change the panel.   2. The capacitor of fan Change the capacitor.   defective.   3. Fan defective.   Unusual sound or heavy 1. Installation   Change the fan.   the Check Installation.   too   of   shaking   air-conditioner   gradient.   2. Fan touches with other   hardware.   Adjust the fan position.   3. The connective pipelines Adjust the position between   collide with each other. the pipelines.   4. The part becomes flexible. Tighten screws.   Installation   1. Installation preparation   If you need to install the air-conditioner on already existing roof vent, the measure of vent   must reach 14×14 (in). If it is not enough of this measurement, you must extend this   measurement. If it is larger than this measurement, you must make a wood frame for the vent   to meet above measurement.   The gradient of install the platform must no more than 5°. If greater than 5° it can be   influenced that condensation water of the air conditioner could overflow.   You must avoid any wire and any pipeline before incision.   2. Please directly install the top of the air-conditioner on the placket and make windward face   toward the front of the vehicle, condenser toward the back of the vehicle. Put the seal   between air-conditioner and placket, and you can sight the four M10 install bores in the   air-conditioner bottom. To those irregular coarse roofs you must have sealant seal up all gaps   in order to prevent rainwater infiltrating into room.   7 3. You must make mounting hole on indoor installation frame align with the hole on the top of   the air-conditioner and tightly connect with 4-M10 special screw.   4. Install canvas-pipe   You must make the flange of the canvas-pipe align with air outlet of the top of air-conditioner   and connect them with screw, gasket, spring gasket and nut.   8 5. Prepare installing of indoor equip: Disassemble the indoor equip.   6.   Install the indoor unit   a) You must install the main of indoor tunnel and installation frame with four ST4.2X16   screw.   Caution: It can be rotated from +90°to -90°.   b) Installing the canvas pipe underparts   You must put into metal flange from canvas pipe under part and tightly nip main vent-pipe   and connect with ST4.2X16 screw. The surplus part is cut out.   c) Install covers board of vent-pipe and indoor main cover board.   d) Connect indoor plastic and gold with two M4×10 screws, gasket and spring gasket.   9 Check   1. Check the complete installing manual to make sure unit is installed correctly and safe   2. Switch on the power, operate the air conditioner according to above methods. If it runs   improperly, for example abnormal noise, running current too high or no temperature, please check   owner’s manual.   10   3. Clean up the installing rubbish and restore decoration to original decor.   11   Warranty   LIMITED WARRANTY   Soleus International Inc. warrants the accompanying Soleus Air RT-135 Roof Top Air Conditioner to   be free of defects in material and workmanship for the applications specified in its operation   instruction for the period of labor and parts specified below.   PARTS   5 YEARS FOR COMPRESSOR   1 YEAR FOR OTHER COMPONENTS   This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine   maintenance. This warranty does not apply to uncrating, setup, installation, removal of the product   for repair or reinstallation of the product after repair..   This warranty does not apply to repairs or replacements necessitated by any cause beyond the control   of Soleus International including, but not limited to, any malfunction, defect or failure caused by or   resulting from unauthorized service or parts, improper maintenance, operation contrary to furnished   instructions, shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect,   accident, incorrect power line voltage, fire, flood or other Acts of God, or normal wear and tear.   Warranty service must be performed by a qualified HVAC contractor. Soleus maintains a centralized   service network to provide parts and assist in resolving service problems if difficulties are encountered.   Soleus agrees to provide service information, sell repair parts and reimburse the dealer / service agent   for parts and services in accordance with Soleus International’s Policies and Procedures. All labor   charges must be pre approved in writing.   SOLEUS INTERNATIONAL MAINTAINS THAT ALL WARRANTIES, INCLUDING   IMPLIED WARRANTY OR MERCHANTABILITY ARE LIMITED TO THE TERMS AND   CONDITIONS SPECIFIED ABOVE. SOLEUS INTERNATIONAL DISCLAIMS ANY   LIBILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT   SHALL SOLEUS INTERNATIONAL INC.’S LIABILITY EXCEED THE RETAIL VALUE OF   THE AIR CONDITIONER.   FOR CUSTOMER SERVICES, WARRANTY CLAIM AND PARTS PURCHASING, CONTACT:   Soleus International Inc.   Tel: 1-888-8 Soleus   Monday through Friday, 9:00 AM to 5:00 PM, PST   Email:   12   |