Samsung Air Conditioner Aqv09j User Manual

INSTALLATION  
MANUAL  
AQV09J Series  
AQV12J Series  
AQV18J Series  
AQV24J Series  
Split - type Air Conditioner  
(Cooling and Heating)  
DB98-27556A(1)  
E
S
F
Safety Precautions  
Keep this installation manual together with the user’s manual in a handy place so that you can find it whenever  
you need to see it after reading this manual thoroughly.  
Make sure to read the following safety precautions carefully before installation.  
Make sure to observe the cautions specified in this manual.  
Conduct a test run of the unit after installation and then explain all system functions to the owner.  
The indications and meanings are as shown below.  
This indicates the possibility of serious injury or death.  
WARNING  
Installation must be carried  
out by a qualified installer.  
Use the specified wires to  
connect the indoor and  
Perform the installation  
securely referring to  
outdoor units securely and  
attach the wires firmly to the  
terminal block connecting  
sections so that the pressure  
is not applied to the sections.  
Inappropriate connection and  
fixing could cause fire.  
the installation manual.  
Incomplete installation  
could cause personal injury  
due to fire, electric shock  
and water leakage or from  
the unit falling.  
Installers are required to read  
the general information  
carefully for safety.  
Do not put the unit near  
dangerous substances to  
prevent fire, explosion or  
injury and do not expose  
the unit to direct sunlight.  
Attach the electrical cover  
to the indoor and outdoor  
unit securely. If not, it could  
result in fire or electric  
Avoid the use of an  
extension cord and do not  
share the power outlet with  
other appliances. Incomplete  
connection, defective  
shock due to dust or water.  
Do not install the unit by  
yourself (owners).  
insulation or exceeding the  
permissible current may cause  
electric shock or fire.  
Make sure to use the part  
provided or specified parts  
for the installation work.  
The use of defective parts  
could cause an injury or  
leakage of water due to a  
fire, an electric shock, the  
unit falling, etc.  
Incorrect installation of the  
unit could cause injury due  
to fire, electric shock and  
water leakage or from the  
unit falling. Consult a dealer  
or a qualified installer.  
Make sure that the refrigerant  
gas does not leak after  
completing the installation.  
If the refrigerant gas of  
the indoor unit leaks and  
comes into contact with the  
fan heater, space heater or  
stove, harmful substances  
will be generated.  
Install the unit in a place  
where it is strong enough  
to hold the product weight.  
When installed in place  
where it is not strong  
enough to withhold the  
product weight, the unit  
could fall and cause injury.  
Make sure to turn off  
the main power when  
setting up the indoor unit  
electrical circuit or power  
cords.  
There is a risk of electric  
shock.  
E-3  
This indicates the possibility of serious injury or death.  
WARNING  
The unit should be installed in  
accordance with the National  
Electrical regulations.  
Check if the voltage and the  
frequency of the main power  
supply are those required for  
the unit to be installed and  
check the connection.  
Do not attempt to repair,  
move, modify or reinstall  
the unit on your own. Make  
sure that these installations  
are carried out by qualified  
personnel to avoid electric  
shock or fire.  
Ensure that the national safety  
code requirements have been  
followed for the main supply  
circuit. Ensure that a properly  
sized and connected ground  
wire is in place.  
Make sure that properly sized  
disconnecting and safety  
switches are installed.  
Use the unit on a single outlet  
circuit. Do not share the power  
outlet with other appliances.  
Obtain the consent by a  
qualified installer before  
connecting the unit to the  
power supply system.  
This indicates the possibility of serious injury or damage to environments when  
operated incorrectly.  
CAUTION  
Check the unit for damage  
that may have taken place  
during transportation and do  
not install or use damaged  
equipment.  
Grounding the unit.  
Fasten a flare nut with a  
torque wrench as specified  
in this installation manual.  
When fastened too tight,  
a flare nut may break after  
a long period of time and  
cause refrigerant leakage.  
Do not connect the ground  
to a gas pipe, water pipe,  
lightning rod or telephone  
grounding. Defective  
grounding could cause  
electric shock.  
All of the manufacturing and  
packaging material used for  
your new appliance are  
compatible with the  
environment and can be  
recycled.  
Do not install the unit in a  
place where it is exposed to  
inflammable gas leakage.  
There is a risk of explosion.  
To prevent injury when  
accidentally touching the  
indoor unit fan, install the  
indoor unit on a place higher  
than 8.2ft (2.5m).  
Dispose of the packaging  
material in accordance with  
the local requirements.  
Install a ground leakage  
breaker depending on the  
installation place (where it is  
humid). If not, it may cause  
electric shock.  
The air conditioner must be  
installed according to the  
national electrical  
regulations.  
This product is an air  
conditioning system and  
contains a coolant that must  
be recovered and disposed  
of in an appropriate way by  
qualified personnel. At the  
end of the life cycle, take it to  
a proper recycling or disposal  
center or return it to the  
dealer so that it can be  
Perform the drainage/piping  
work securely according to  
the installation manual.  
If not, water could drop from  
the unit and household  
goods could get wet and  
damaged.  
The maximum input power &  
current is measured  
according to the IEC standard  
and the input power &  
current is measured  
according to the ISO  
standard.  
disposed correctly.  
E-4  
PREPARING FOR INSTALLATION  
Choosing the Installation Location  
Indoor Unit  
Outdoor Unit  
Where airflow is not blocked  
Where cool air can be distributed throughout the room  
Install the refrigerant piping length and the height  
difference of both indoor and outdoor units as  
indicated in the installation diagram  
Wall that prevents vibration and is strong enough to hold the  
product weight  
Where it is not exposed to strong wind  
Well ventilated and dustless places  
Out of the direct sunlight and rain  
Where neighbors are not annoyed by operation sound or hot air  
Solid wall or support that prevents vibration and is strong  
enough to hold the product weight  
Where there is no risk of flammable gas leakage  
When installing the unit at a high place be sure to fix the unit  
legs  
9.9ft (3m) or more away from the TV or radio (to prevent the  
screen from being distorted or noise from being generated)  
Install the unit horizontally  
Out of the direct sunlight  
3.3ft (1m) or more away from the TV or radio  
(to prevent the screen from being distorted or noise from being  
generated)  
As far away as possible from fluorescent and incandescent lights  
(so that the remote control can be operated well)  
A place where the air filter can be replaced easily  
CAUTION  
Avoid the following places to prevent malfunction of the unit  
- Where there is machine oil  
- Where sulfide gas exists  
- Salty environment such as the seaside areas  
- Other special atmosphere areas  
Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.  
11.8 inch (300mm) or more  
4.9 inch (125mm)  
or more  
4.9 inch (125mm)  
or more  
Wrap the refrigerant pipes and the drain  
hose with the absorbent pad and vinyl  
tape. Refer to page 15 for further details.  
You can select the direction  
of draining. (left or right)  
“Bmaximum total  
pipe Height  
23.6 inch (600mm)  
minimum  
“Amaximum  
total pipe length  
11.8 inch (300mm)  
minimum  
11.8 inch (300mm)  
minimum  
23.6 inch (600mm)  
minimum  
Model  
AQV09J  
AQV12J  
AQV18J  
AQV24J  
“A”  
“B”  
26.2ft(8m)  
49.2ft(15m)  
98.4ft(30m) 49.2ft(15m)  
The appearance of the unit may be different from the diagram depending on the model.  
E-5  
PREPARING FOR INSTALLATION  
Accessories  
The following accessories are supplied with the air conditioner:  
The number of each accessory is indicated in parentheses.  
Accessories in the Indoor Unit Case  
Installation Plate (1)  
Remote Control (1)  
Batteries for  
User’s Manual (1)  
Installation Manual (1)  
Service Manual (1)  
Remote Control (2)  
Accessories in the Outdoor Unit Case  
Drain Plug (1)  
Rubber Leg (4)  
The flare nuts are attached to the end of each pipe of an evaporator or a service port.  
Use the nuts when connecting the pipes.  
E-6  
INSTALLING THE AIR CONDTIONER  
Fixing the Installation Plate  
Before fixing the installation plate to the wall or window frame, you must  
determine the position of the 2.56 inch (65mm) hole through which the cable,  
pipe and hose pass to connect the indoor unit to the outdoor unit.  
When facing the wall, the pipe and cable can be connected from the:  
Right  
Left  
Underside (right)  
Rear (right or left)  
1
2
Determine the position of the pipe and drain hose hole as seen in the picture  
and drill the hole with an inner diameter of 2.56 inch (65mm) so that it slants  
slightly downwards.  
Pipe hole  
Ø2.56inch(65mm)  
If you fix the indoor unit to a...  
Wall  
Follow step(s)...  
3.  
A
C
Window frame  
4 to 6.  
AQV09J  
AQV12J  
AQV18J  
AQV24J  
Fix the installation plate to the wall giving attention to the weight of the  
indoor unit.  
3
inch  
mm  
120  
27  
inch  
mm  
140  
34  
If you mount the plate to a concrete wall with anchor bolts, the anchor  
bolts must not project more than 0.8 inch (20mm).  
A
B
C
4.72  
1.06  
2.68  
5.51  
1.34  
2.68  
68  
68  
Determine the positions of the wooden uprights to be attached to the  
window frame.  
4
5
6
Attach the wooden uprights to the window frame giving attention to the  
weight of the indoor unit.  
Attach the installation plate to the wooden uprights using tapping screws as  
seen in the picture.  
Purging the Indoor Unit  
Upon delivery, there may be inert gas inside the indoor unit. Purge the gas  
from the indoor unit before connecting the assembly pipe.  
Unscrew the caps at the end of each pipe.  
Result: All inert gas exhausts from the indoor unit.  
To prevent dirt or foreign substances from getting into the pipes during  
installation, do NOT remove the caps completely until you are ready to  
connect the pipes.  
E-7  
INSTALLING THE AIR CONDTIONER  
Installing and Connecting the Assembly Pipe of the Indoor Unit  
There are 2 refrigerant pipes of different diameters:  
The smaller one is for the liquid refrigerant  
The larger one is for the gas refrigerant  
A short pipe is already fitted to the air conditioner. You may need to extend the  
pipe using the assembly pipe. (optional)  
The connection procedure for the refrigerant pipe varies according to the exit  
position of the pipe when facing the wall:  
Right(A)  
Left(B)  
A
B
Underside(C)  
Rear  
C
1
Cut out the appropriate knock-out piece on the rear of the indoor unit unless  
you connect the pipe directly from the rear.  
Smooth the cut edges.  
2
3
Remove the protection caps of the pipes and connect the assembly pipe  
to each pipe. Tighten the nuts first with your hands, and then with a torque  
wrench, applying the following torque:  
Outer Diameter  
1/4 inch (6.35mm)  
3/8 inch (9.52mm)  
1/2 inch (12.80mm)  
5/8 inch (15.88mm)  
Torque  
10.1~12.3ft  
18.1~20.3ft  
27.5~30.4ft  
31.8~34.7ft  
lb (140~170 kgf  
lb (250~280 kgf  
lb (380~420 kgf  
lb (440~480 kgf  
cm)  
cm)  
cm)  
cm)  
If you want to shorten or extend pipes, refer to page 9.  
Cut off the remaining foam insulation.  
4
5
If necessary, bend the pipe to fit along the bottom of the indoor unit.  
Then pull it out through the appropriate hole.  
The pipe should not project from the rear of the indoor unit.  
The bending radius should be 4 inch(100mm) or more.  
Pass the pipe through the hole in the wall.  
6
7
For further details on how to connect to the outdoor unit and purge the air,  
refer to page 13.  
The pipe will be insulated and fixed permanently into position after  
finishing the installation and the gas leak test; refer to page 14 for  
further details.  
E-8  
INSTALLING THE AIR CONDTIONER  
Cutting or Extending the Pipe  
A 24.6ft (7.5m) pipe is supplied with the air conditioner. (optional)  
The length of the pipe can be:  
Model  
AQV09J  
AQV12J  
AQV18J  
AQV24J  
“A”  
Extended up to “A”  
Shortened as required  
49.2ft(15m)  
If you need a pipe longer than 24.6ft (7.5m):  
98.4ft(30m)  
You must extend the assembly cable.  
For further details on how much refrigerant(R410A) should be  
added, refer to Page 13.  
1
2
Make sure that you have the required tools (pipe cutter, reamer, flaring tool  
and pipe holder.)  
If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut  
edge remains at 90° with the side of the pipe (see examples of correctly and  
incorrectly cut edges below.)  
Oblique  
Rough  
Burr  
To prevent a gas leak, remove all burrs at the cut edge of the pipe using a  
reamer.  
3
4
Put a flare nut slightly into the pipe and modify the flare.  
Outer Diameter (D)  
Depth (A)  
1/4 inch (6.35mm)  
3/8 inch (9.52mm)  
1/2 inch (12.80mm)  
5/8 inch (15.88mm)  
0.05 inch (1.3mm)  
0.07 inch (1.8mm)  
0.08 inch (2.0mm)  
0.09 inch (2.2mm)  
Check if you flared the pipe correctly (see examples of incorrectly flared pipes  
below.)  
5
Inclined  
Damaged Surface  
Cracked  
Uneven Thickness  
Align the pipes to connect them easily. Tighten the flare nuts first with your  
hands, and then with a torque wrench, applying the following torque:  
6
7
Outer Diameter  
Torque  
1/4 inch (6.35mm)  
3/8 inch (9.52mm)  
1/2 inch (12.80mm)  
5/8 inch (15.88mm)  
10.1~12.3ft  
18.1~20.3ft  
27.5~30.4ft  
31.8~34.7ft  
lb (140~170 kgf  
lb (250~280 kgf  
lb (380~420 kgf  
lb (440~480 kgf  
cm)  
cm)  
cm)  
cm)  
For further details on how to connect to the outdoor unit and purge the air,  
refer to page 13.  
E-9  
INSTALLING THE AIR CONDTIONER  
Installing and Connecting the Drain Hose of the Indoor Unit  
When installing the drain hose for the indoor unit, check if condensation draining is adequate.  
When passing the drain hose through the 65-mm hole drilled in the wall, check the following:  
2inch  
(50mm)  
less  
Ditch  
Do NOT place the end  
of the drain hose in a  
hollow.  
The hose must  
NOT slant upwards.  
Do NOT bend the hose  
in different directions.  
Keep a clearance of  
The end of the drain  
hose must NOT be  
placed under water.  
at least 2inch (50mm)  
between the end of the  
hose and the ground.  
Drain hose installation:  
1
2
Shield  
If necessary, connect the 6.6 ft (2m) extension drain hose to the drain hose.  
If you use the extension drain hose, insulate the inside of the extension drain  
hose with a shield.  
Drain hose  
Extension drain hose  
Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain  
hose tightly with a clamp.  
3
If you don’t use the other drain hose hole, block it with a rubber stopper.  
Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.  
4
5
Pass the drain hose through the hole in the wall. Check if it slants downwards  
as seen in the picture.  
The hose will be fixed permanently into position after finishing  
the installation and the gas leak test; refer to page 14 for further details.  
E-10  
INSTALLING THE AIR CONDTIONER  
Changing Direction of the Drain Hose  
You can select the direction of the drain hose, depending on where you want to  
install the indoor unit.  
1
2
3
Detach the rubber cap with the flyer.  
Screws hole  
Screw  
Detach the drain hose by pulling it and turning to the left.  
Drain hose  
Insert the drain hose by fixing it into the groove of the drain hose and the  
outlet of the drain pan.  
Drain pan outlet  
Rubber cap  
Attach the rubber cap with a screwdriver by turning it to the right until it fixes  
to the end of the groove.  
4
One of the diagrams has an illustration with the words “Screws hole” that  
should be changed to “Screw hole.”  
Installing and Connecting the Drain Hose of the Outdoor Unit  
While heating, ice may accumulate. During the process of defrosting, check if  
condensation draining is adequate. For adequate draining, do the following:  
1
Insert the drain plug into the drain hole on the underside of the outdoor unit.  
There are “A” drain holes on the underside. You can use any hole for  
your convenience.  
Model  
AQV09J  
AQV12J  
AQV18J  
AQV24J  
“A”  
Drain hole  
3
1
Connect a drain hose to the drain plug.  
2
3
Ensure that condensation draining is adequate.  
E-11  
INSTALLING THE AIR CONDTIONER  
Connecting the Assembly Cable  
The outdoor unit is powered from the indoor unit through the assembly cable.  
If the outdoor unit is more than 24.6ft (7.5m) away from the indoor unit, you  
must extend the cable. The maximum length of the cable is “A.  
Model  
AQV09J  
AQV12J  
AQV18J  
AQV24J  
“A”  
49.2ft(15m)  
98.4ft(30m)  
1
2
Extend the assembly cable if necessary.  
Open the front grille by pulling on the tabs on the lower right and left sides of  
the indoor unit.  
Remove the screw securing the connector cover.  
3
4
Pass the assembly cable through the rear of the indoor unit and connect  
the assembly cable to terminals as seen in the picture.  
Each wire is labeled with the corresponding terminal number.  
09/12/18/24  
Indoor unit  
Pass the other end of the cable through the 65mm hole in the wall.  
Close the connector cover, tightening the screw carefully.  
Close the front grille.  
5
6
7
8
9
1(L) 2(N) F1 F2  
1(L)  
1(L)  
2(N)  
F1  
F2  
E
E
2(N)  
F1  
L
F2  
N
Remove the terminal board cover on the side of the outdoor unit.  
Connect the cables to the terminals as seen in the picture.  
F1 F2 1(L) 2(N)  
Outdoor unit  
Each wire is labeled with the corresponding terminal number.  
Please make sure to use copper supply wires.  
N
E
L
Connect the grounding conductor to the grounding terminals.  
Close the terminal board cover, tightening the screw carefully.  
Connect the power cable to the indoor unit.  
10  
11  
12  
Circuit Breaker  
(Main power)  
Screws on terminal block must not  
be unscrewed with the torque less  
than 0.87ft•lb (12 kgf•cm).  
In Russia and Europe, consult with the supply authority to determine  
the supply system impedance before installation.  
Power cable specification  
Use  
AWG  
Cross sectional area (mm²)  
Main Power Supply 3-wire  
power cable  
13 or fewer  
2.5 or more  
Indoor Power Supply  
3-wire power cable  
16 or fewer  
16 or fewer  
1.5 or more  
1.5 or more  
2-wire assembly cable  
The designs and shape are subject to  
change according to the model.  
Connect the power cable to the auxiliary circuit breaker.  
If every pole fails to connect to the power supply, it must be  
incorporated in a wire with a contact opening of ≥0.118inch(3mm).  
E-12  
COMPLETING THE INSTALLATION  
Purging the Connected Pipes  
The outdoor unit is loaded with sufficient R410A refrigerant for a 24.6ft (7.5m)  
pipe You should purge the air in the indoor unit and in the pipe.  
If air remains in the refrigerant pipes, it affects the compressor. It may cause  
reduction of cooling capacity and malfunction.  
Refrigerant for air purging is not charged in the outdoor unit.  
Use Vacuum Pump as seen in the picture.  
1
2
Connect each assembly pipe to the appropriate valve on the outdoor unit and  
tighten the flare nut.  
Outdoor unit  
Indoor unit  
Gas pipe side  
Tighten the flare nut first with your hands, and then with a torque wrench,  
applying the following torque:  
Liquid pipe side  
Outer Diameter  
Torque  
1/4 inch (6.35mm)  
3/8 inch (9.52mm)  
1/2 inch (12.80mm)  
5/8 inch (15.88mm)  
10.1~12.3ft  
18.1~20.3ft  
27.5~30.4ft  
31.8~34.7ft  
lb (140~170 kgf  
lb (250~280 kgf  
lb (380~420 kgf  
lb (440~480 kgf  
cm)  
cm)  
cm)  
cm)  
Connect the charging hose of the low-pressure side of manifold gauge to a  
gas service port as seen in the picture.  
3
The valve connection port of low-pressure side is 5/16 inch(7.94mm).  
Open the valve of the low pressure side of manifold gauge counterclockwise.  
4
5
Purge the air in the connected pipes using the vacuum pump for about  
10 minutes.  
- Close the valve of the low pressure side of manifold gauge clockwise.  
- Make sure that pressure gauge shows -0.1MPa(-76cmHg) after about  
10 minutes.  
This procedure is very important to avoid a gas leak.  
Vacuum  
Pump  
- Turn off the vacuum pump.  
- Remove the hose of the low pressure side of manifold gauge.  
Set a valve cork of liquid and gas service port to the open position.  
6
7
Valve stem  
Stem cap  
Mount the valve stem nuts and the service port cap to the valve, and tighten  
them at the torque of 13.2ft lb (183kgf cm) with a torque wrench.  
A
(gas)  
Check for a gas leak paying particular attention to the 3-way valve’s stem nuts  
and to the service port cap.  
8
9
B
5/16 inch (7.94mm)  
(liquid)  
For further detailed information how to check the low pressure after  
installation, Please refer to the Service Manual.  
Adding Refrigerant  
You must add refrigerant if the pipe is longer than 24.6ft (7.5m).  
Then…  
If you use a  
pipe…  
AQV09J/AQV12J  
AQV18J/AQV24J  
You can install 49.2ft(15m)  
of connecting pipe to the  
maximum, and you don’t  
have to charge any additional  
refrigerant.  
You can install 98.4ft(30m) of connecting  
pipe to the maximum, and you should  
charge 0.16oz(15g) of refrigerant R410A  
additionalyfor each extra feet(metre).  
longer than  
24.6ft (7.5m)  
shorter than  
24.6ft (7.5m)  
The purge time is normal. The purge time is normal.  
E-13  
Refer to the Service Manual for further details.  
COMPLETING THE INSTALLATION  
Performing the Gas Leak Tests  
Make sure to check for gas leaks before completing the installation process  
C
D
(connecting the assembly pipe and hose between indoor unit and outdoor  
unit, insulating the cables, hose and pipe, and fixing the indoor unit to the  
installation plate)  
To check for gas leaks on the...  
Using a leak detector, check the...  
Indoor unit  
Flare nuts at the end of sections  
C and D.  
Outdoor unit  
Valves on sections A and B.  
A
B
E-14  
COMPLETING THE INSTALLATION  
Fixing the Indoor Unit in Place  
After checking for gas leaks in the system, insulate the pipe, hose and cables.  
Then place the indoor unit on the installation plate.  
1
To avoid condensation problems, place heat-resistant polyethylene foam  
separately around each refrigerant pipe in the lower part of the indoor unit.  
Wrap the refrigerant pipe and the drain hose in the rear of the indoor unit with  
the absorbent pad.  
2
Wind the pipe and hose three times to the end of the indoor unit with the  
absorbent pad. (0.79 inch(20mm) interval)  
Wind the pipe, assembly cable and drain hose with insulation tape.  
3
4
Place the bundle (the pipe, assembly cable and drain hose) in the lower part of  
the indoor unit carefully so it doesn’t project from the rear of the indoor unit.  
Installation plate  
Hook the indoor unit to the installation plate and move the unit to the right  
and left until it is securely in place.  
5
Wrap the rest of the pipe with vinyl tape.  
6
7
Attach the pipe to the wall using clamps (optional).  
E-15  
COMPLETING THE INSTALLATION  
Fixing the Outdoor Unit in Place  
Install the outdoor unit to a stable base to avoid the generation of noise and  
vibration, especially when installing the unit close to a neighbor.  
If you install the outdoor unit in a place exposed to strong winds or at a height,  
fix it to an appropriate support (wall or ground).  
“ X ”  
1
Place the outdoor unit as indicated on the top of the unit to let the  
discharged air out properly.  
Fix the outdoor unit to an appropriate support using anchor bolts.  
2
3
Rubber leg  
If the outdoor unit is exposed to strong winds, install shield plates around the  
outdoor unit so that the fan can operate correctly.  
Model  
AQV09J  
AQV12J  
AQV18J  
AQV24J  
“X”  
“Y”  
Secure the rubber leg to prevent the generation of noise and vibration.  
1.77ft(538mm) 0.95ft(290mm)  
2.17ft(660mm) 1.12ft(340mm)  
Final Check and Trial Operation  
To complete the installation, perform the following checks and tests to ensure  
that the air conditioner operates correctly.  
1
Check the following:  
Strength of the installation site  
Tightness of pipe connection to detect gas leak  
Electric wiring connection  
Heat-resistant insulation of the pipe  
Drainage  
Grounding conductor connection  
Correct operation (follow the steps below)  
Press the  
button and check the following:  
2
3
4
The indicator on the indoor unit lights up.  
The airflow blade opens and the fan gears up for operation.  
Press any button and check the following:  
The appropriate indicator lights up and the air conditioner operates  
according to the selected mode or function.  
Press the button and check the following:  
The airflow blades work properly.  
E-16  
COMPLETING THE INSTALLATION  
Providing Information for User  
After finishing the installation of the air conditioner, explain the following to  
the user: (refer to appropriate pages in the User’s Manual.)  
1
2
3
4
5
6
How to start and stop the air conditioner  
How to select the modes and functions  
How to adjust the temperature and fan speed  
How to adjust the airflow direction  
How to set the timers  
How to clean and replace the filters  
When you complete the installation successfully, hand over the User’s  
Manual and this Installation Manual to the user for storage in a handy and  
safe place.  
E-17  

Linak 00ch01aus 00 User Manual
Panasonic Cu 2e18jbk User Manual
Ryobi P103 User Manual
Samsung Aw09lh Series User Manual
Samsung Scx 4720f User Manual
Sanyo 36x72r User Manual
Savin Sdc306e User Manual
Xerox 7400 User Manual
Xerox All In One Printer 2121l User Manual
Xerox Workcentre 5790 User Manual