PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC‐12000E, AC‐12000H
Portable Air Conditioner
Owner’s Manual
k0045
PARTS LIST
Front:
Back:
1. Control panel
2. Louvers
5. Air filter
6. Air inlet
3. Carrying handle
4. Casters
7. Cord storage
8. Exhaust air outlet
9. Rubber plug / drainage point
Accessories:
10. Exhaust hose
11. Hose adaptor (goes over the hose and
into the window kit)
12. Extendable window kit
13. Activated carbon filter
14. Hose for continuous drainage
15. Remote control
2
k0045
INSTALLATION INSTRUCTIONS
Installing the Exhaust Hose and Window Kit:
Wall or Window
Adapter
Window Kit
FIG.5
FIG.6
1. Open the window and insert the window kit into the open gap.
2. Close the window until the window kit is held securely. This technique may also be
used for sash windows.
3. Fit the exhaust hose into the exhaust air outlet located on the back of the air
conditioner.
4. Attach one end of the hose adapter onto the exhaust hose.
5. Attach the other end of the hose adapter to the window kit.
3
k0045
Positioning the Exhaust Hose:
•
•
Insert the exhaust hose
into the back of the unit
and tighten it into place.
FIG.7
Avoid kinks and bends in
the exhaust hose. This
can cause moist air to
accumulate, resulting in
overheating and
unexpected shut offs.
•
The exhaust hose may be
extended from 12 inches
(300 mm) to 59 inches
(1500 mm), but for
maximum cooling
FIG.8
efficiency, use the
shortest hose length
possible.
FIG.9
WARNING!
The included exhaust hose is
specifically designed to fit the
specifications of this unit. Do not
extend it with your own hose, as
this can cause the air conditioner to
malfunction.
FIG.10
4
k0045
Installing the Activated Carbon
Filter:
1. Remove the filter frame from the
unit.
2. Separate the filter from the filter
frame.
3. Remove the activated carbon filter
from its plastic bag.
4. Insert the activated carbon filter
into the filter frame.
Reattach the filter onto the
filter frame.
5.
6. Insert the filter set into the unit.
FIG.11
5
k0045
OPERATING INSTRUCTIONS
Control Panel
2
1
3
7
4 5
6
22
8
AUTO
COOL
FAN
hi
lo
SPEED
TIMER
SLEEP
MODE
21
20
19
18
17
9
10
11
HEAT
UP
DOWN
ON/OFF
12
13
ION
COMP.
16
15
14
FIG.12
1. Fan speed (ventilation) button
2. Timer button
12. Power indicator
13. Full water tank indicator
14. ON/OFF (power) button
15. Sleep mode button
3. Display window
4. Remote control receiver
5. Heater indicator (for AC-12000H only ) 16. Ionizer button
6. Mode selection button
17. Compressor indicator
7. Automatic mode indicator
8. Cooling mode indicator
9. Fan mode indicator
18. Ionizer indicator
19. Sleep mode indicator
20. Timer indicator
10. Temperature increase button
11. Temperature decrease button
21. Low fan speed indicator
22. High fan speed indicator
Turning the Unit On and Off:
•
Press the ON/OFF button. The unit will automatically begin operating in cooling mode
on low fan speed. The default temperature is 75 o F.
•
At this time, the indicator lights will show any functions that are in progress. Please note
that the display window will only show ambient room temperatures ranging from 32o F to
122o F.
•
To turn the unit off, press ON/OFF button again.
6
k0045
Setting the Mode/Function:
1. Press the MODE button to select the desired mode (cooling, fan or heating). Heating
mode is only available on the AC-12000H.
2. The selected mode’s indicator light will turn on.
Setting the Temperature:
1. Press the “Up” or “Down” button to change the set temperature.
2. The display window will indicate the set temperature. If no temperature is set, the
display will show the ambient room temperature.
3. Please note that the preset temperature for cooling is 75 o F for cooling and 68 o F for
heating.
Setting the Fan/Ventilation Speed:
Press the SPEED button to select the desired fan speed (high or low). The appropriate
indicator light (high or low) will turn on accordingly.
Setting the Timer:
1. Press TIMER button to set the desired number of operating hours (from 1 to 24 hours).
When the set time has been reached, the machine will turn off automatically. The
display window will show the number of hours being set as you press the TIMER button.
If the TIMER is not set, the unit will work continuously.
2. By pressing the timer but without selecting any other modes or settings, you can set the
number of hours to be delayed before the unit turns on. For example, if you set the
timer to “2,” the unit will automatically turn on after 2 hours.
Sleep Mode:
1. When in cooling mode, press the SLEEP button. The set temperature will increase1o F
on the first hour, another 1o F on the second hour, and then maintain that temperature.
2. When in heating mode, press the SLEEP button. The set temperature will decrease 1o
F on the 1st hour, another 1o F on the second hour, and then maintain that temperature.
3. In sleep mode, the fan will automatically be set to low. By pressing the SLEEP button
again, the set temperature and fan speed will revert back to previous settings.
4. The unit will shut down automatically after it has been in sleep mode for 12 hours.
5. Sleep mode will not work when the unit is in fan, dehumidification or auto mode. It will
only work in cooling or heating mode.
7
k0045
Heating Mode:
When the air conditioner is in heating mode, ambient warm air is recycled and used to heat
your immediate area. The exhaust pipe will still need to be fitted onto the unit in order
for the cold air to be removed. When in heating mode, the machine can be set on HIGH
or LOW speed.
Ionizer:
Press IONIZER button to activate the ionizer function.
Error Messages:
If there is an error with the air conditioner, the LCD screen will display “E1” or “E2.” If either
of these error messages appears, please contact the manufacturer or a service center.
All of the above functions can be controlled with the
included remote.
The remote requires 2 AAA batteries.
FIG.13
Please Note:
1. To prolong the life of the compressor, after turning off the unit, please wait at least
3 minutes before turning it back on.
2. The cooling system will turn off if the ambient temperature is lower than the set
temperature. However, the fan will continue operating at the set level. Once the
ambient temperature rises above the set temperature, cooling will resume.
3. The heating system will turn off if the ambient temperature is higher than the set
temperature. The ventilation fan will continue operating at the set level. Once the
ambient temperature drops below the set temperature, heating will resume.
4. This machine is equipped with an anti-frost function. When using the heating function in
low temperatures, the heater will occasionally stop heating in order to melt any frost
that has accumulated within the air conditioner. Normal operation will resume in a few
moments.
8
k0045
DRAINING THE UNIT
During the cooling process, some water will be extracted from the air and stored within
the unit’s water reservoir.
If the water reservoir is full, both the compressor and motor will stop and the unit will
beep (press any button to stop the beeping sound). The full water tank indicator light
will also start flashing.
To resume cooling, empty the reservoir by following these steps:
1. Turn off the air conditioner and unplug it
from the wall socket. To prevent water
leakage, avoid moving the unit when full.
2. Place a container (such as a small pan)
underneath the hole.
3. Remove the rubber plug from the hole
and allow the water to drain out.
4. When the container is almost full, replace
the plug back into the hole.
5. Repeat these steps until the water
reservoir is completely empty.
Water hole
6. Replace the rubber plug and make sure it
is firmly in place.
Rubber plug
Drain knob
7. Turn the unit back on. The full tank
indicator light should turn off.
FIG.14
9
k0045
For Continuous Drainage:
•
•
•
Remove the rubber plug from
the drainage port and retain it
for future use.
Connect the drain tube to the
drainage port as shown (fig.
17).
Rubber plug
Drain knob
Connect the other end of the
hose to a drain.
FIG.15
•
The drain tube may be extended
by adding an extension tube
with a suitable connector.
Drain tube
FIG.16
Please Note:
1. The drain must be at or
below the level of the
drainage port.
2. The full water tank indicator
light will not work when the
unit is being continuously
drained.
Original drain tube
Extended drain tube(OD:
)
0.7”
3. To extend the drain tube, you
can connect it with another
hose with an overall diameter
of approximately 0.7” .
FIG.17
10
k0045
For Heating Mode:
While using the heating function,
please note the following:
1. In order to properly exhaust cool
air, make sure the exhaust hose
and window kit are properly
installed (refer to page 6 for
instructions).
2. Set up the air conditioner for
continuous drainage using the
drain tube (refer to page 13 for
instructions).
3. The working range for the
heating function is 32° F to
68°F. The unit may not provide
optimal heating if used in
FIG.18
temperatures outside this range.
11
k0045
MAINTENANCE INSTRUCTIONS
Always unplug the air conditioner from the power supply before cleaning.
To maximize the efficiency of the air conditioner, regularly clean the unit.
Cleaning the Housing:
•
•
Use a soft, damp cloth to wipe the body clean.
Never use harsh chemicals, gasoline, detergents, chemically treated cloths, or other
cleansing solutions. These all could possibly hurt the cabinet.
Cleaning the Filter:
•
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the
filters. Rinse the filter under running water (no warmer than 104oF).
Thoroughly dry the filter before replacing it back into the unit.
•
End of Season Storage:
•
Completely drain any condensed
water from the unit.
•
Set the air conditioner on fan mode
(ventilation only) for a few hours to
dry the inside of the unit.
Cord wrap
•
•
Clean or change the filter.
Unplug and wrap the power cord
around the cord wrap as shown (fig.
20).
•
Place the unit back in its original
carton and store it in a clean, dry
area.
FIG.19
12
k0045
TROUBLESHOOTING
The air conditioner does not work.
y
y
y
y
Is the air conditioner plugged in?
Is the power outlet functioning correctly?
Is the full water tank indicator light flashing?
Is the ambient room temperature lower than the
set temperature?
The unit does not produce adequate
cooling.
y
Is the unit placed in direct sunlight? If so, close
any curtains or move the unit to a more shaded
area.
y
y
y
y
y
y
Are too many windows or doors open?
Are there too many people in the room?
Are there additional heat sources in the room?
Is the filter dusty or dirty?
Is the air inlet or air outlet blocked?
Is the ambient room temperature lower than the
set temperature?
The unit is noisy.
y
y
Is the machine positioned unevenly? Make sure
the air conditioner is positioned on an even, solid
surface.
The compressor does not work.
Is the compressor’s overheat protection function
activated? If so, wait for the temperature to drop
and then turn on the unit again.
☆ Never try to repair or dismantle the unit yourself. Unauthorized repairs
can void your warranty and endanger the user.
13
k0045
TECHNICAL SPECIFICATIONS
Model Number:
Power Consumption for
Cooling*
AC-12000E
AC-12000H
1166W / 11A
1166W/11A
Power Consumption for
Heating *
N/A
1054W/10.1A
Air Volume (max. speed)
Dehumidification Capacity
Voltage / Frequency
Compressor Type
Refrigerant Type
Number of Fan Speeds
Timer
440m3/h
440m3/h
1.2L/hour
1.2L/hour
115V, 60Hz
Rotary
R-410A
2
1~24 hours
Ø 5” X 59.06”
Exhaust Pipe Dimensions
Net Weight
63.9 lbs
63.9 lbs
Dimensions
14.4"x 15.6" x 29.3"
Notes:
1. Heating function is only for model number AC-12000H.
2. The data marked with '*' may vary for technical reasons; for more accurate data, please refer
to the rating label found on the back of the unit.
3. Measuring condition for the above specifications:
Cooling –DB = 95°F (35°C), WB= 82.94°F (28.3° C)
Heating – DB= 68°F (20°C) , WB= 59°F (15°C)
* D.B. = dry bulb temperature = room temperature
*W.B. = wet bulb temperature = relati ve humidity
14
|