METROLOGIC INSTRUMENTS, INC.
MS7120 Orbit® Presentation
Laser Scanner
Installation and User’s Guide
TABLE OF CONTENTS
Introduction
Product Overview............................................................................................. 1
RS232, or Light Pen......................................................................................... 7
Stand-Alone Keyboard Wedge....................................................................... 10
Design Specifications......................................................................................... 22
ii
TABLE OF CONTENTS
Serial Configuration.................................................................................... 30
Upgrading the Firmware..................................................................................... 31
Scanner Pinout Connections.......................................................................... 32
Safety............................................................................................................. 35
iii
INTRODUCTION
Orbit® is an aggressive, omnidirectional laser bar code scanner ideal for use in
retail, convenience, liquor and specialty stores Designed to be lightweight and
rugged, Orbit’s small size makes it ideal for applications where counter space is
limited. It’s unique contoured shape allows it to be picked-up and used as a
hand-held scanner when scanning large or bulky items.
Key Product Features
• Fully Automatic Scanning Operation
• Adjustable Scan Head
• User-Replaceable Single Cable Interface To Host (Powerlink Compatible)
• Seven Beeper Tones
• Configurable Depth of Field
• Firmware updates are easily loaded into Flash memory
• OPOS and JPOS System Compatible
• Support For Common Interfaces Including USB (See Table Below)
• Easy Bar Code Configuration
ORBIT
MODEL NUMBER
INTERFACE
RS232 Low Speed USB,
MS7120-38
Keyboard Emulation Mode or Serial Emulation Mode*
MS7120-41
MS7120-47
MS7120-106
RS232/Light Pen Emulation
Keyboard Wedge,
Stand-Alone Keyboard and RS232 Transmit/Receive
RS485S and Full Speed USB
* Configurable for Keyboard Emulation Mode or Serial Emulation Mode.
Default setting is Keyboard Emulation Mode.
Applicable for IBM® Host applications.
S
1
INTRODUCTION
Scanner and Accessories
BASIC KIT COMPONENTS
Part No.
MS7120
Description
Orbit Presentation Laser Bar Code Scanner
MS7120 Orbit Presentation Laser Bar Code Scanner
Installation and User’s Guide
00-02282x
00-02407x
MetroSelect® Configuration Guide
OPTIONAL ACCESSORIES
Part No.
Description
AC to DC Power Transformer - Regulated 5.2VDC @ 1A output.
46-00525
90VAC to 255VAC United States, Canada and Japan
90VAC to 255VAC Continental European
90VAC to 255VAC United Kingdom
90VAC to 255VAC Australia
46-00526
46-00527
46-00528
46-00529
46-00530
90VAC to 255VAC China
90VAC to 255VAC India
RS232 PowerLink Cable with Built in Power Jack
straight cord, short strain relief
59-59000x -3
Other items may be ordered for the specific protocol being used. To order additional items,
contact the dealer, distributor or call Metrologic’s customer service department at
1-800-436-3876.
2
INTRODUCTION
Scanner and Accessories
OPTIONAL ACCESSORIES
Description
Part No.
MVC**
RS485S Applications
Metrologic Voltage Converter Cable ±12VDC to +5.2VDC
** Contact a Metrologic customer service representative for additional
information on the MVC cable series and the host connections available.
Keyboard Wedge PowerLink Cable
59-59002x-3
straight cord, short strain relief
Stand Alone Keyboard PowerLink Cable
59-59020x-3
straight cord, short strain relief
USB Full Speed Cable, Locking Plus-Power™ Type A
54-54213x-N-3
straight cord, short strain relief
USB Full Speed Cable, Locking Plus-Power™ Type A
straight cord, short strain relief
54-54214x-N-3
This cable is for use with full speed
USB (-106) interface only.
USB Low Speed Communication Cable, Type A
59-59235x-N-3
straight cord, short strain relief
45-45619
Counter/Wall Mount Kit
Other items may be ordered for the specific protocol being used. To order additional items,
contact the dealer, distributor or call Metrologic’s customer service department at
1-800-436-3876.
S Applicable for IBM® Host applications.
3
INTRODUCTION
Scanner Components
ITEM NO
DESCRIPTION
1
2
3
4
5
6
7
White LED (see page 12)
Blue LED (see page 12)
Red Output Window (Laser Aperture)
Speaker (see page 12)
Pin Hole for Cable Release
10-Pin RJ45, Female Socket (see page 33)
Adjustable Scan Head, 30°
Figure 1. Scanner Components
Cable Removal
1. Locate the small ‘pin-hole’ on the bottom of
the scanner near the cable.
2. Bend an ordinary paperclip into the shape
shown.
3. Insert the paperclip into the small ‘pin-hole’.
4. There will be a faint ‘click’ when the cable
lock is released. Pull gently on the strain-
relief of the PowerLink cable to remove it
from the scanner.
Figure 2. Cable Release
4
INTRODUCTION
Caution and Serial Number Labels
Figure 3. Labeling Locations on the Bottom of the Scanner and Examples
Caution
To maintain compliance with applicable standards, all circuits connected to the scanner must
meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1.
To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm
EN/IEC 60950-1, the power source should meet applicable performance requirements for a
limited power source.
Maintenance
Smudges and dirt on the unit's window can interfere with the unit's performance.
If the window requires cleaning, use only a mild glass cleaner containing no
ammonia. When cleaning the window, spray the cleaner onto a lint free, non-
abrasive cleaning cloth then gently wipe the window clean.
If the unit's case requires cleaning, use a mild cleaning agent that does not
contain strong oxidizing chemicals. Strong cleaning agents may discolor or
damage the unit's exterior.
5
INTRODUCTION
Mounting Specifications
Optional Wall/Counter Mount
Item
Description
Qty.
1
a. Locking Plate, MLPN 50-50302
b. Base Cover, MLPN 50-50301
1
c. #7 x 1.00" Wood Screw, MLPN 18-18013
d. M3 x 8 mm Flathead Screw, MLPN 18-18004
3
4
Figure 4. Kit Components
1. Drill three #39 pilot holes.
Note the position Orbit will rest
(see Figure 5). Use the dimensions
provided in Figure 5 or the locking
plate as a template to drill three
#39 pilot holes in the mounting
surface.
Figure 5
2. Attach the locking plate to the wall/counter.
Secure the locking plate to the counter/wall with the three #7 x 1.00" wood
screws provided (see Figure 6).
3. Attach the base plate to the Orbit.
Secure the base cover to the bottom of Orbit using the four M3 x 8 mm
screws provided (see Figure 7).
4. Mount Orbit to the locking plate.
Hold Orbit 90° clockwise from the desired position then lower it over the
locking plate until it sits flush to the countertop. Twist Orbit counter
clockwise 90° to lock the scanner in place (see Figure 8).
Figure 8
Figure 7
Figure 6
6
INSTALLATION
RS232, Light Pen Emulation
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end
of the PowerLink cable into the
10-pin socket on the MS7120.
3. Connect the 9-pin female end of the
PowerLink cable to the host device.
4. Plug the external power supply into the
power jack on the PowerLink cable.
Check the AC input requirements
of the power supply to make sure
the voltage matches the AC outlet.
The outlet must be located near
the equipment and be easily
accessible.
5. Connect AC power to the transformer.
6. Turn on the host device.
Figure 9.
When the scanner first receives power, the blue and white LED will
toggle on and off then the scanner will beep once.
Plugging the scanner into the serial port of the PC does not guarantee
that scanned information will appear at the PC. A software driver and
correct configuration setting are also required for proper
communication to occur.
Powering the MS7120 directly from the host device can cause
interference with the operation of the scanner or the computer. Not
all computers supply the same current. For this reason, Metrologic
recommends using an external power supply. For additional
information contact a Metrologic customer service representative.
See page 5.
7
INSTALLATION
RS485S
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end
of the MVC cable into the
10-pin socket on the MS7120.
3. Connect the other end of the MVC
cable to the host device.
4. Turn on the host device.
Figure 10.
When the scanner first receives power, the blue and white LED will
toggle on and off then the scanner will beep once.
Plugging the scanner into the serial port of the PC does not
guarantee that scanned information will appear at the PC. A software
driver and correct configuration setting are also required for proper
communication to occur.
S Applicable for IBM® Host applications.
8
INSTALLATION
Keyboard Wedge
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of the
PowerLink cable into the 10-pin
socket on the MS7120.
3. Disconnect the keyboard from the
host device.
4. Connect the “Y” end of the PowerLink
cable to the keyboard and the
keyboard port on the host PC. If
necessary use the male/female
adapter cable supplied with the
scanner for proper connections.
5. Plug the external power supply into the
power jack on the PowerLink cable.
Check the AC input requirements
of the power supply to make sure
the voltage matches the AC
outlet. The outlet must be
located near the equipment and
be easily accessible.
Figure 11.
6. Connect AC power to the transformer.
7. Turn on the host device.
When the scanner first receives power, the blue and white LED will
toggle on and off then the scanner will beep once.
Powering the MS7120 directly from the host device can sometimes
cause interference with the operation of the scanner or the computer.
Not all computers supply the same current through the keyboard port.
For this reason, Metrologic recommends using an external power
supply. For additional information contact a Metrologic customer
service representative.
See page 5.
9
INSTALLATION
Stand-Alone Keyboard
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end
of the PowerLink cable into the
10-pin socket on the MS7120.
3. Connect the other end of the
PowerLink cable to the keyboard
port on the host device.
4. Plug the external power supply into
the power jack on the PowerLink
cable.
Check the AC input
requirements of the power
supply to make sure the
voltage matches the AC
outlet. The outlet must be
located near the equipment
and be easily accessible.
5. Connect AC power to the transformer.
6. Turn on the host device.
Figure 12.
When the scanner first receives power, the blue and white LED will
toggle on and off then the scanner will beep once.
Powering the MS7120 directly from the host device can sometimes
cause interference with the operation of the scanner or the computer.
Not all computers supply the same current through the keyboard port.
For this reason, Metrologic recommends using an external power
supply. For additional information contact a Metrologic customer
service representative.
See page 5.
10
INSTALLATION
Full Speed or Low Speed USB
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of
the USB cable into the 10-pin
socket on the MS7120.
3. Plug the other end of the USB
interface cable into the host
device’s USB port.
4. Turn on the host device.
When the scanner first receives
power, the blue and white LED
will toggle on and off then the
scanner will beep once.
Figure 13.
As a default, the MS7120-38 leaves the factory with USB Keyboard
Emulation Mode enabled. Scan the following bar code to configure
the MS7120-38 for USB Serial Emulation Mode.
³
3
1
6
4
6
0
Plugging the scanner into the USB port of the PC does not guarantee
that scanned information will appear at the PC. A software driver and
the correct configuration settings are also required for proper
communication to occur.
For Previous User’s of the MX009
In order for the new integrated USB Orbit* to function with the same
serial emulation driver as the old external USB Orbit, scan the
following bar code.
³
3
1
6
4
7
0
* Rev L Orbits or above.
11
SCANNER OPERATION
Audible Indicators
When the MS7120 is in operation, it provides audible feedback to indicate the
status of the scanner. Eight settings are available for the tone of the beep
(normal, six alternate tones and no tone). For instructions on how to change the
tone of the beeper, refer to the MetroSelect Configuration Guide (00-02407).
One Beep
When the scanner first receives power the blue and white LED will toggle on
and off. The scanner will beep once, then the LEDs will stop toggling and the
blue LED will remain on to indicate the scanner is ready to scan.
When the scanner successfully reads a bar code, the white LED will flash and
the scanner will emit a beep*. If the scanner does not beep once and the white
light does not flash, then the bar code has not been successfully read.
Razzberry Tone
This is a failure indicator. Refer to Failure Mode Indicators on page 14.
When in configuration mode, a razzberry tone indicates that an invalid bar code
has been scanned.
Three Beeps - During Operation
When entering configuration mode† the scanner will beep three times and the
white and blue LED will start to toggle on and off. The blue LED and the white
LED will toggle on and off until the scanner exits the configuration mode.
Upon exiting configuration mode†, the white LED will flash three times and the
scanner will beep three times. The blue LED will then stay on indicating the
scanner is ready to scan.
When using one-code-configuring, the scanner will emit a unique beep three
times after scanning. This indicates that the single configuration bar code has
successfully configured the scanner.
Three beeps* can also indicate a communications timeout during normal
scanning mode.
Three Beeps - On Power Up
This is a failure indicator. Refer to Failure Mode Indicators on page 14.
* This feature is configuration dependent. Refer to the MetroSelect Configuration Guide
to enable this feature.
†
Refer to the Multi-Code Configuration Method in the MetroSelect Configuration Guide.
12
SCANNER OPERATION
Visual Indicators
The MS7120 is equipped with a blue and a white LED that indicates the
scanner’s state and the status of the current scan when the unit is in operation.
Figure 14. LED Location
No LEDs
The LEDs will not be illuminated if the scanner is not receiving power from the
host or transformer.
Steady Blue
When the laser is active, the blue LED is illuminated. The blue LED will remain
on until the laser is deactivated.
During the power save mode, the laser will turn on and off. During this period,
the blue LED will remain on.
Steady Blue and Single White Flash
When the scanner successfully reads a bar code, the white LED will flash and
the scanner will beep once. If the white LED does not flash or the scanner
does not beep once, then the bar code has not been successfully read.
Steady White and Blue
After a successful scan, the scanner transmits the data to the host device.
Some communication modes require that the host inform the scanner when
data is ready to be received. If the host is not ready to accept the information,
the scanner’s white LED will remain on until the data can be transmitted.
Alternating (Toggling) Blue and White
This indicates the scanner is in configuration mode. A razzberry tone indicates
that an invalid bar code has been scanned in this mode.
13
SCANNER OPERATION
Failure Mode Indicators
Flashing Blue with One Razzberry Tone
This indicates that the scanner has experienced a laser subsystem failure.
Return the unit to an authorized service center for repair.
Synchronized Flashing of Blue and White with Two Razzberry Tones
This indicates that the scanner has experienced a motor failure. Return the unit
to an authorized service center for repair.
Three Beeps - On Power Up
If the scanner beeps three times on power up, then the nonvolatile memory
that holds the scanner configuration may have failed. First, check the
scanner’s settings. Then, try to re-configure the scanner. If the problem
persists return the unit to an authorized service center for repair.
14
SCANNER OPERATION
Depth of Field Specifications*
Normal Scan Zone
Specifications are based on a 0.33 mm (13 mil) bar code.
Figure 15. MS7120 Normal Depth of Field
Reduced Scan Zone
Specifications are based on a 0.33 mm (13 mil) bar code.
Figure 16. MS7120 Reduced Depth of Field
* All specifications are subject to change without notice.
15
SCANNER OPERATION
Depth of Field by Bar Code Element Width*
Normal Scan Zone
MINIMUM BAR CODE ELEMENT WIDTH
A
B
-
C
-
D
-
E
F
-
G
H
J
-
K
mm
.13
5.2
.19
7.5
.25
10
.33
13
.66
26
mils
-
-
-
-
-
Figure 17. Normal Scan Zone by Bar Code Element Width
* All specifications are subject to change without notice.
16
SCANNER OPERATION
Depth of Field by Bar Code Element Width*
Reduced Scan Zone
MINIMUM BAR CODE ELEMENT WIDTH
A
-
B
C
-
D
-
E
F
-
G
H
J
-
K
mm
.15
5.7
.19
7.5
.25
10
.33
13
.66
26
mils
-
-
-
-
-
Figure 18. Reduced Scan Zone by Bar Code Element Width
* All specifications are subject to change without notice.
17
TROUBLESHOOTING GUIDE
The following guide is for reference purposes only. Contact a Metrologic
representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited
warranty terms on page 38.
Symptoms
Possible Cause(s)
Solution
All Interfaces
During power
up the unit
beeps three
times.
There is a non-volatile
RAM failure.
Contact a Metrologic service
representative.
During power
up the unit
razzes once
and the blue
LED flashes.
Contact a Metrologic service
representative.
There is a VLD failure.
During power
up the unit
razzes twice
and both LEDs
flash in unison.
There is a scanner
motor failure.
Contact a Metrologic service
representative.
Check the transformer, outlet
and power strip. Make sure the
cable is plugged into the
scanner.
The unit has no
LEDs, beeper
or motor spin.
No power is being
supplied to the
scanner.
Some host systems cannot
supply enough current to power
the Orbit. Use the power supply
included with the scanner.
The unit has no
LEDs and / or
beeper.
No power is being
supplied to the
scanner from host.
The beeper is disabled. Enable the beeper.
No tone is selected. Select a tone.
The unit powers
up but does not
beep.
18
TROUBLESHOOTING GUIDE
Symptoms
Possible Cause(s)
Solution
All Interfaces
UPC/EAN, Code 39, Interleaved
2 of 5, Code 93, Code 128 and
Codabar are enabled by default.
Verify that the type of bar code
being read has been selected
The unit is trying to
scan a particular
symbology that is not
enabled.
The unit powers
up but does not
scan and/or
beep.
The scanner has been
configured for a
Verify that the bar code that is
being scanned falls into the
criteria.
character length lock,
or a minimum length
and bar code being
scanned does not
satisfy the configured
criteria.
Typical of Non-UPC/EAN codes.
The scanner defaults to a
minimum of four character bar
code.
The unit scans
a bar code, but
locks up after
the first scan
(the white LED
stays on).
If the scanner is setup to support
ACK/NAK, RTS/CTS,
XON/XOFF or D/E, verify that
the host cable and host are
supporting the handshaking
properly.
The scanner is
configured to support
some form of host
handshaking but is not
receiving the signal.
Verify that the scanner’s data
format matches the format
required by the host.
Make sure that the scanner is
connected to the proper host
port.
The unit scans
but the data
transmitted to
the host is
The scanner’s data
format does not match
the host system
requirements.
incorrect.
There are
multiple scans
upon
presentation of
code.
The same symbol
timeout is set too
short.
Adjust the same symbol timeout
for a longer time increment.
19
TROUBLESHOOTING GUIDE
Symptoms
Possible Cause(s)
Solution
All Interfaces
The bar code may
have been printed
incorrectly.
Check if it is a check digit,
character or border problem.
Scanner beeps
at some bar
codes and NOT
for others of the
same bar code
symbology.
The scanner is not
configured correctly for
the type of bar code.
Check if check digits are set
properly.
The minimum symbol
length setting does not
work with the bar code.
Check if the correct minimum
symbol length is set.
RS232 Only
The com port at the
host is not working or
is not configured
properly.
The unit powers
up OK and
scans OK but
does not
communicate
properly to the
host.
Check to make sure that the
baud rate and parity of the
scanner and the communication
port match and that the program
is looking for RS232 data.
The cable is not
connected to the
proper com port.
The com port is not
operating properly.
20
TROUBLESHOOTING GUIDE
Symptoms
Possible Cause(s)
Solution
RS232 Only
The host is
The scanner and host
may not be configured
for the same interface.
Check that the scanner and the
host are configured for the same
interface.
receiving data
but the data does
not look correct.
The inter character
delay needs to be
added to the
Add some inter-character delay to
the transmitted output by using
the MetroSelect Configuration
Guide (MLPN 00-02407).
Characters are
being dropped.
transmitted output.
Keyboard Wedge Only
The unit scans
Make sure the scanner is
configured for the appropriate
mode.
the bar code
but there is no
data.
The unit may not be
configured correctly.
Make sure that the proper PC
type (ie. AT or PS2 ) is selected.
The unit scans
but the data is
not correct.
The unit may not be
configured correctly.
Verify correct country code and
data formatting are selected.
Adjust the inter-scan delay.
Increase the inter-scan code
delay setting. Adjust whether
the F0 break is transmitted. It
may be necessary to try both
settings.
The unit is not
transmitting
each character.
The unit may not be
configured correctly.
Alpha characters
show as lower
case.
Enable caps lock detect setting
of the scanner to detect whether
the PC is operating in caps lock.
The computer is in
caps lock mode.
Everything
These characters may
not be supported by
the current country’s
key, look up table.
works except
for a couple of
characters.
Try operating the scanner
in Alt Mode.
21
DESIGN SPECIFICATIONS
MS7120
Operational
Light Source: Visible Laser Diode (VLD) @ 650 nm
Laser Power: Less than 1 mW average
Normal Depth of Field: 0 mm – 215 mm
0.33 mm (13 mil) bar code
Reduced Depth of Field: 0 mm – 190 mm
Scan Speed: 1120 scan lines per second
No. of Scan Lines: 20
Motor Speed: 3360 RPM
Min Bar Width: 0.13 mm (5.0 mil)
All standard 1-D bar codes including RSS-14,
RSS-Expanded, and RSS-14 Limited
Decode Capability:
System Interfaces:
RS232, Keyboard Wedge, Stand-Alone Keyboard, Light Pen
Emulation, RS485S, USB (low speed and full speed)
Print Contrast: 35% minimum reflectance difference
Up to 80 data characters
No. Characters Read:
Maximum number will vary based on symbology and density.
Beeper Operation: 7 tones or no beep
Blue = laser on, ready to scan
White = good read, decoding
Indicators (LED):
Mechanical
Width: Base - 102 mm (4.0")
Orb - 80 mm (3.1")
Depth : 105 mm (4.1")
Height: 150 mm (5.9")
Weight: 14.5 oz (410 g)
Orb Tilt: 30° Vertical
Specifications subject to change without notice.
S Applicable for IBM® Host applications.
22
DESIGN SPECIFICATIONS
MS7120
Electrical
Voltage Supply: 5VDC ± 0.25V
Operating Power: 0.9 W
Standby Power: 0.85 W
Operating Current: 180 mA typical at 5VDC
Standby Current: 170 mA typical at 5VDC
DC Transformers: Class II; 5.2VDC @ 1A
For regulatory compliance information, see pages 35 - 37.
Environmental
Operating Temperature: -20°C to 40°C (-4°F to 104°F)
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% relative humidity, non-condensing
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None required
Specifications subject to change without notice.
23
APPLICATIONS AND PROTOCOLS
The model number on each scanner includes the scanner number and factory
default communications protocol.
VERSION
IDENTIFIER
SCANNER
COMMUNICATION PROTOCOL(S)
RS232 Low Speed USB,
Keyboard Emulation or Serial Emulation
38
41
47
Full RS232C/Light Pen Emulation
MS7120
Keyboard Wedge, Stand-Alone Keyboard and
RS232 Transmit/Receive
106
RS485S and Full Speed USB
S Applicable for IBM® Host applications.
The MS7120 scanner with built-in PC Keyboard Wedge Interface is designed to
be used for keyboard emulation only. Many RS232 configurable
functions (e.g. formatting) available in other Metrologic scanners are also
available as keyboard wedge functions.
The following are the most important selectable options specific to the keyboard
wedge.
Keyboard Type
•
•
** AT (includes IBM® PS2 models 50, 55, 60, 80)
IBM PS2 (includes models 30, 70, 8556)
Keyboard Country Type
• USA **
• Belgium
• French
• German
• Hungarian
• Italian
• Swiss
• Japanese
• Russian Cryillic
• Slovenian
• Spanish
• Sweden/Finland
• Turkish
• United Kingdom
** Default setting. For a complete list of default settings, see the Default
Settings - Communication Parameters table starting on page 25 of this
guide. Refer to the MetroSelect® Configuration Guide (MLPN 00-02407) or
MetroSet2’s help files for information on how to change the default settings.
24
DEFAULT SETTINGS - COMMUNICATION PARAMETERS
Many functions of the scanner can be "configured" - that is enabled or disabled.
The scanner is shipped from the factory configured to a set of default conditions.
The default parameter of the scanner has an asterisk ( * ) in the charts on the
following pages. If an asterisk is not in the default column then the default setting
is Off or Disabled. Every interface does not support every parameter. If the
interface supports a parameter listed in the charts on the following pages, a
check mark (ꢀ) will appear.
LIGHT
PEN
PARAMETER
DEFAULT
RS232
RS485S KBW
USB
UPC/EAN
Code 128
Code 93
Codabar
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
*
*
*
*
*
Interleaved 2 of 5 (ITF)
MOD 10 Check on ITF
Code 11
Code 39
*
Full ASCII Code 39
MOD 43 Check on Code 39
MSI-Plessey
MSI-Plessey
10/10 Check Digit
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
MSI-Plessey
MOD 10 Check Digit
*
Paraf Support
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
Variable
4
ITF Symbol Lengths
Minimum Symbol Length
Symbol Length Lock
RSS14 Enable
None
RSS14 ID “]e0”
*
*
*
RSS14 App ID “01”
RSS14 Check Digit
RSS Expanded Enable
S Applicable for IBM® Host applications.
25
DEFAULT SETTINGS - COMMUNICATION PARAMETERS
LIGHT
PEN
PARAMETER
DEFAULT
RS232
RS485S KBW
USB
Expanded ID “]e0”
ꢀ ꢀ ꢀ ꢀ ꢀ
*
RSS Limited Enable
RSS Limited ID “]e0”
RSS Limited App ID “01”
RSS Limited Check Digit
Bars High as Code 39
Spaces High as Code 39
Bars High as Scanned
Spaces High as Scanned
DTS/SIEMENS
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
*
*
*
*
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
DTS/NIXDORF
*
NCR F
NCR S
Poll Light Pen Source
Beeper Tone
ꢀ
Normal
Before Transmit
None
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
Beep/Transmit Sequence
Communication Timeout
Razzberry Tone on Timeout
Three Beeps on Timeout
No Beeps on Timeout
Enter Power Save Mode
*
5 mins.
Same Symbol Rescan Timeout:
500 msecs Configurable in 50
msec steps (MAX 6.35 seconds)
ꢀ ꢀ ꢀ ꢀ ꢀ
*
Intercharacter Delay
Configurable in 1 msec steps
(MAX 255 msecs)
1 msecs
10 msecs in KBW
ꢀ
ꢀ ꢀ ꢀ
1
Number of Scan Buffers
ꢀ ꢀ ꢀ ꢀ ꢀ
S Applicable for IBM® Host applications.
26
DEFAULT SETTINGS - COMMUNICATION PARAMETERS
LIGHT
PEN
PARAMETER
DEFAULT
RS232
RS485S KBW
USB
Transmit UPC-A
Check Digit
ꢀ ꢀ ꢀ ꢀ ꢀ
*
Transmit UPC-E
Check Digit
ꢀ ꢀ ꢀ ꢀ ꢀ
Expand UPC-E
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
Convert UPC-A to EAN-13
ꢀ
Transmit Lead Zero on
UPC-E
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
Convert EAN-8 to EAN-13
ꢀ
Transmit UPC-A
Number System
ꢀ ꢀ ꢀ ꢀ ꢀ
*
Transmit UPC-A Manufacturer
ID#
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
*
*
Transmit UPC-A Item ID#
Transmit Codabar
Start/Stop Characters
ꢀ
ꢀ
ꢀ
ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
CLSI Editing (Enable)
Transmit Mod 43 Check Digit on
Code 39
Transmit Code 39
Stop/Start Characters
ꢀ
ꢀ
ꢀ
ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
Transmit Mod 10/ITF
Transmit MSI-Plessey Check
Characters
Space
9600
Parity
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Baud Rate
8 Data Bits
7 Data Bits
*
2
Stop Bits
Transmit Sanyo ID Characters
ꢀ ꢀ
S Applicable for IBM® Host applications.
27
DEFAULT SETTINGS - COMMUNICATION PARAMETERS
LIGHT
PEN
PARAMETER
DEFAULT
RS232
RS485S KBW
USB
Nixdorf ID
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ ꢀ
LRC Enabled
UPC Prefix
UPC Suffix
ꢀ ꢀ
ꢀ ꢀ
ꢀ
ꢀ
Transmit AIM ID Characters
ꢀ
ꢀ ꢀ
STX Prefix
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ETX Suffix
ꢀ ꢀ
ꢀ ꢀ
ꢀ ꢀ
ꢀ ꢀ
ꢀ ꢀ
Carriage Return
*
*
Line Feed - disabled by default
in KBW
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Tab Prefix
Tab Suffix
Serial
Emulation
Mode Only
“DE” Disable Command
“FL” Laser Enable Command
DTR Handshaking Support
RTS/CTS Handshaking
Character RTS/CTS
Message RTS/CTS
XON/XOFF Handshaking
ACK/NAK
Serial
Emulation
Mode Only
*
Serial
Emulation
Mode Only
Serial
Emulation
Mode Only
as
code 39
Two Digit Supplements
Five Digit Supplements
Bookland
ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
as
code 39
as
code 39
977 (2 digit) Supplemental
Requirement
ꢀ ꢀ ꢀ ꢀ ꢀ
S Applicable for IBM® Host applications.
28
DEFAULT SETTINGS - COMMUNICATION PARAMETERS
LIGHT
PEN
PARAMETER
DEFAULT
RS232
RS485S KBW
USB
Supplements are not Required
ꢀ ꢀ ꢀ ꢀ ꢀ
*
*
Two Digit Redundancy
Five Digit Redundancy
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
100 msec to Find Supplement
Configurable in 100msec steps
(MAX 800 msec)
ꢀ ꢀ ꢀ ꢀ ꢀ
*
as
code 39
Coupon Code 128
ꢀ
ꢀ ꢀ ꢀ
7 avail.
Configurable Code Lengths
ꢀ ꢀ ꢀ ꢀ ꢀ
10 avail.
ꢀ ꢀ
Configurable Prefix Characters
Configurable Suffix Characters
ꢀ
ꢀ
10 avail.
ꢀ ꢀ
ꢀ ꢀ
Prefixes for individual Code
Types
ꢀ
Editing
ꢀ ꢀ ꢀ ꢀ ꢀ
Inter Scan-Code Delay
Configurable
(100 µsec steps)
800 µsec
ꢀ
Keyboard
ꢀ
Emulation
Mode Only
Function/Control Key Support
Configurable in 5.6 µsec steps
1 msec
ꢀ
Normal Depth of Field
Reduced Depth of Field
ꢀ ꢀ ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ ꢀ ꢀ
*
S Applicable for IBM® Host applications.
29
SCANNER CONFIGURATION
CONFIGURATION MODES
The MS7120* Series scanner has three modes of configuration.
•
•
Bar Codes
The MS7120 can be configured by scanning the bar codes included in the
MetroSelect Configuration Guide (MLPN 00-02407). These manuals can be
downloaded FREE of charge from Metrologic’s website
(www.metrologic.com).
MetroSet2
This user-friendly Windows-based configuration program allows the end-
user to simply ‘point-and-click’ at the desired scanner options. This program
can be downloaded FREE of charge from Metrologic’s website
1-800-ID-METRO.
•
Serial Configuration
This mode of configuration is ideal for OEM applications. This mode gives
the end-user the ability to send a series of commands using the serial port of
the host system. The commands are equivalent to the numerical values of
the bar codes located in the MetroSelect Configuration Guide
(MLPN 00-02407).
* Revision L or later.
30
UPGRADING THE FIRMWARE
The MS7120 is part of Metrologic's line of scanners with flash upgradeable
firmware. The upgrade process requires, a new firmware file supplied to the
customer by a customer service representative and Metrologic's MetroSet2
software . A personal computer running Windows 95 or greater with an
available RS232 serial or USB port is required to complete the upgrade.
PowerLink Cable #54-54014 is required when using RS232 for the
upgrade process. This cable can be ordered from Metrologic at
1-800-ID-METRO. Do not use the standard cable supplied with
keyboard wedge or RS485S scanner interface kits. If using USB for the
upgrade process, the standard USB cable provided with the scanner
can be used.
To upgrade the firmware in the MS7120:
1. Plug the scanner into a serial communication port on the host system.
2. Start the MetroSet2 software.
3. Click on the plus sign (+) next to POS Scanners to expand the supported
scanner list.
4. Choose the MS7120 Orbit or Orbit(L+)* from the list.
5. Click on the Configure Orbit/7120 (L+)* Scanner button.
6. Choose Flash Utility from the options list located on the left side of the
screen.
7. Click on the Open File button in the Flash Utility window.
8. Locate and open the flash upgrade file supplied by Metrologic.
9. Select the COM port that the scanner is connected to on the host system.
10. Verify the settings listed in the Flash Utility window.
11. Click on the Flash Scanner button to begin the flash upgrade.
12. A message will appear on the screen when the upgrade is complete.
Metrologic's customer service department can be reached at
1-800-ID-METRO or 1-800-436-3876.
MetroSet2 is available for download, at no additional cost, from
* Revision L or later.
S Applicable for IBM® Host applications.
31
SCANNER AND CABLE TERMINATIONS
Scanner Pinout Connections
The MS7120 scanner interfaces terminate to a 10-pin modular socket.
The serial number label indicates the interface enabled when the scanner is
shipped from the factory.
Figure 19.
MS7120-47 Keyboard Wedge
MS7120-41
and Stand-Alone Keyboard
RS232C and Light Pen Emulation
Pin Function
Pin Function
1
2
3
Ground
1
2
3
Ground
RS232 Transmit Output
RS232 Receive Input
PC Data
RS232 Transmit Output
RS232 Receive Input
RTS Output
4
4
5
PC Clock
5
CTS Input
6
7
KB Clock
PC +5V
6
7
DTR Input/LTPN Source
Reserved
8
KB Data
8
LTPN Data
9
+5VDC
9
+5VDC
10
Shield Ground
10
Shield Ground
MS7120-106
RS485S and
Full Speed USB
MS7120-38
RS232 Low Speed USB
Pin Function
Pin Function
1
2
3
4
5
Ground
1
2
3
4
5
Ground
RS232 Transmit Output
RS232 Receive Input
IBM A+
IBM B-
USB D+
RS232 Transmit Output
RS232 Receive Input
RTS Output
CTS Input
D+
6
6
7
USB +V
7
V USB
8
USB D-
8
D-
9
+5VDC
9
+5VDC
10
Shield Ground
10
Shield Ground
S Applicable for IBM® Host applications.
32
SCANNER AND CABLE TERMINATIONS
Cable Connector Configurations (Host End)
“Standard” PowerLink Cable
MLPN 59-59000x -3 straight
Pin
1
Function
Shield Ground
2
RS232 Transmit Output
RS232 Receive Input
DTR Input/Light Pen Source
Power/Signal Ground
Light Pen Data
3
4
5
6
9-Pin D-Type Connector
7
CTS Input
8
9
RTS Output
+5VDC
USB Power/Communication Cable
MLPN 54-54213x-N-3,
54-54214x-N-3 or 59-59235x-N-3
Pin
Function
PC +5V/V_USB
1
2
3
4
D-
D+
Locking, Type A
MLPN 54-54213x-N-3 or
Non-Locking, Type A
MLPN 54-54214x-N-3
Ground
MLPN 54-54214x-N-3
Shield Shield
Stand Alone Keyboard PowerLink
Cable MLPN 59-59020x-3
Pin
1
Function
PC Data
2
No Connect
3
Power Ground
+5VDC PC Power to KB
PC Clock
4
6-Pin Male Mini-DIN Connector
5
6
No Connect
33
SCANNER AND CABLE TERMINATIONS
Cable Connector Configurations (Host End)
Keyboard Wedge PowerLink Cable
59-59002x -3
Pin
1
Function
Keyboard Clock
2
Keyboard Data
No Connect
3
4
Power Ground
+5 Volts DC
5-Pin DIN, Female
5
Pin Function
1
2
3
PC Data
No Connect
Power Ground
4
5
6
+5 Volts DC
PC Clock
No Connect
6-Pin DIN, Male
Metrologic will supply an adapter cable with a 5-pin DIN male connector on one
end and a 6-pin mini DIN female connector on the other. According to the
termination required, connect the appropriate end of the adapter cable to the
PowerLink cable, leaving the necessary termination exposed for connecting to
the keyboard and the keyboard port on the PC.
Keyboard Wedge Adapter Cable
Pin Function
1
2
3
4
5
PC Clock
PC Data
No Connect
Power Ground
+5 Volts DC
5-Pin DIN, Male
Pin Function
1
2
3
4
5
6
Keyboard Data
No Connect
Power Ground
+5 Volts DC
Keyboard Clock
No Connect
6-pin Mini DIN, Female
34
REGULATORY COMPLIANCE
Safety
ITE Equipment
IEC 60950-1, EN 60950-1
Laser
Laser Class 1: IEC 60825-1:1993+A1+A2,
EN 60825-1:1994+A1+A2
Caution
Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous laser light exposure. Under no circumstances should the
customer attempt to service the laser scanner. Never attempt to look at the laser beam,
even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to
look into the device. Doing so could result in hazardous laser light exposure. The use of
optical instruments with the laser equipment will increase eye hazard.
Atención
La modificación de los procedimientos, o la utilización de controles o ajustes distintos de
los especificados aquí, pueden provocar una luz de láser peligrosa. Bajo ninguna
circunstancia el usuario deberá realizar el mantenimiento del láser del escáner. Ni intentar
mirar al haz del láser incluso cuando este no esté operativo. Tampoco deberá abrir el
escáner para examinar el aparato. El hacerlo puede conllevar una exposición peligrosa a
la luz de láser. El uso de instrumentos ópticos con el equipo láser puede incrementar el
riesgo para la vista.
Attention
L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner
de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le
scanner ou le laser. Ne regardez jamais directement le rayon laser, même si vous croyez
que le scanner est inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce
faisant, vous vous exposez à une rayonnement laser qú êst hazardous. L'emploi
d'appareils optiques avec cet équipement laser augmente le risque d'endommagement de
la vision.
Achtung
Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder
Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen
Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den
Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist. Öffnen Sie niemals
den Scanner, um in das Gerät hineinzusehen. Wenn Sie dies tun, können Sie sich einer
gefährlichen Laserstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser
Laserausrüstung erhöht das Risiko einer Sehschädigung.
Attenzione
L’utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel
presente Manuale può provocare delle esposizioni a raggi laser rischiose. Il cliente non
deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai il
raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per
guardare dentro l’apparecchio. Facendolo potete esporVi ad una esposizione laser
rischiosa. L’uso di apparecchi ottici, equipaggiati con raggi laser, aumenta il rischio di
danni alla vista..
35
REGULATORY COMPLIANCE
EMC
Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022
Immunity: CISPR 24, EN 55024
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Class A Devices
The following is applicable when the scanner cable is greater in length than 3
meters (9.8 feet) when fully extended:
Les instructions ci-dessous s’appliquent aux cables de scanner dépassant 3
métres (9.8 pieds) de long en extension maximale:
Folgendes trifft zu, wenn das Scannerkabel länger als 3 Meter ist:
This equipment has been tested and found to comply with limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at their own expense. Any unauthorized changes or
modifications to this equipment could void the user’s authority to operate this device.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Notice
This Class A digital apparatus complies with Canadian ICES-003.
Remarque
Cet appareil numérique de classe A est conforme à la norme canadienne NMB-003.
European Standard
Warning
This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Funkstöreigenschaften nach EN55022:1998
Warnung!
Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich
Funkstörungen verursachen. In diesem Fall kann vom Betreiber verlangt werden,
angemessene Massnahmen durchzuführen.
Standard Europeo
Attenzione
Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe
causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure.
Attention
Ce produit est de classe “A”. Dans un environnement domestique, ce produit peut être la
cause d’interférences radio. Dans ce cas l’utiliseteur peut être amené à predre les mesures
adéquates.
36
REGULATORY COMPLIANCE
EMC
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Class B Devices
The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in
length when fully extended:
Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3
métres (9.8 pieds) de long en extension maximale:
Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Notice
This Class B digital apparatus complies with Canadian ICES-003.
Remarque
Cet appareil numérique de classe B est conforme à la norme canadienne NMB-003.
37
LIMITED WARRANTY
The MS7120 Orbit® scanners are manufactured by Metrologic at its Suzhou, China facility. The MS7120
Orbit scanners have a three (3) year limited warranty from the date of manufacture. Metrologic warrants
and represents that all MS7120 Orbit scanners are free of all defects in material, workmanship and
design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and
local laws, regulations and ordinances pertaining to their production and labeling.
This warranty is limited to repair, replacement of product or refund of product price at the sole discretion
of Metrologic. Faulty equipment must be returned to one of the following Metrologic repair facilities:
Blackwood, New Jersey, USA; Madrid, Spain; or Suzhou, China. To do this, contact the appropriate
Metrologic Customer Service/Repair Department to obtain a Returned Material Authorization (RMA)
number.
In the event that it is determined the equipment failure is covered under this warranty, Metrologic
shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit
and return such repaired or replaced Product without charge for service or return freight, whether
distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase
price.
This limited warranty does not extend to any Product which, in the sole judgment of Metrologic,
has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage
due to use or misuse produced from integration of the Product into any mechanical, electrical or
computer system. The warranty is void if: (i) the case of the Product is opened by anyone other
than Metrologic's repair department or authorized repair centers; or (ii) any software is installed on
the Product other than a software program approved by Metrologic.
THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES
OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES,
WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF
CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE
EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL
METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES,
INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON
BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR
INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT
SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO
METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY
CHANGES TO THE PRODUCT DESCRIBED HEREIN.
CORPORATE HEADQUARTERS,
NORTH AMERICA
METROLOGIC EUROPEAN REPAIR CENTER
(MERC)
Metrologic Instruments, Inc.
90 Coles Rd.
Blackwood, NJ 08012-4683
Customer Service Department
Tel: 1-800-ID-METRO
Fax: 856-228-6673
Metrologic Eria Ibérica, SL
C/Alfonso Gomez, 38-40, 1D
28037 Madrid
Tel: +34 913 751 249
Fax: +34 913 270 437
Email: [email protected]
MTLG AUTO ID INSTRUMENTS (SHANGHAI) CO., LTD
Suzhou Sales Office
BLK A, Room# 03/03-04
No.5 Xinghan Street, Xinsu Industrial Square
China-Singapore Suahou Industrial Park, Suzhou, PRC
Tel: 86-512-67622550
Fax: 86-512-67622560
Email: [email protected]
38
PATENTS
Patent Information
This METROLOGIC product may be covered by, but is not limited to, one or
more of the following U.S. Patents:
U.S. Patent No.;
4,960,985; 5,081,342; 5,216,232; 5,260,553; 5,340,971; 5,340,973;
5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,557,093;
5,591,953; 5,616,908; 5,627,359; 5,637,852; 5,661,292; 5,777,315;
5,789,730; 5,789,731; 5,811,780; 5,828,048; 5,844,227; 5,925,870;
6,029,894; 6,098,885; 6,209,789; 6,257,492; 6,286,760; 6,299,067;
6,347,743; 6,412,696; 6,460,767; 6,572,018; 6,604,684; 6,619,549;
6,637,655; 6,651,890; 6,860,427; 6,863,217; 6,975,456; 7,044,383;
7,097,105; D408,806
No license right or sublicense is granted, either expressly or by implication,
estoppel, or otherwise, under any METROLOGIC or third party intellectual
property rights (whether or not such third party rights are licensed to
METROLOGIC), including any third party patent listed above, except for an
implied license only for the normal intended use of the specific equipment,
circuits, and devices represented by or contained in the METROLOGIC products
that are physically transferred to the user, and only to the extent of
METROLOGIC’S license rights and subject to any conditions, covenants and
restrictions therein.
Other worldwide patents pending.
39
INDEX
A
host....................................... 18–21
AC .................................. see power
accessories ...............................2, 3
adapter ....................................9, 34
I
immunity...................................... 36
indicator
B
audible. 4, 12–14, 18–21, 22, 25–
29
bar code ......................................30
bar width......................................22
beep ............................see indicator
blue .............................see indicator
failure ...................................... 14
visual ........... 4, 12–14, 18–21, 22
interface ................................ 22, 24
Keyboard Wedge. 1, 3, 9, 21, 25–
29
C
Light Pen ................... 1, 7, 25–29
OCIA ................................. 25–29
RS232 ....... 1, 2, 7, 20, 21, 25–29
RS485 ....................... 1, 8, 25–29
Stand-Alone Keyboard .... 1, 3, 10
USB................. 1, 2, 3, 11, 25–29
cable
communication.2, 3, 4, 7–11, 33–
34
pin assignments...........32, 33–34
caution.....................................5, 35
CE ..........................see compliance
class ............................................37
communication
parameters.........................25–29
compliance ........................5, 35, 36
configuration................................30
default................................25–29
current .........................................23
customer service ...................38, 42
K
keyboard
country..................................... 24
type ......................................... 24
keyboard emulation mode........... 11
Keyboard Wedge ........see interface
L
D
label .............................................. 5
laser........................................ 4, 35
LED.............................see indicator
Light Pen.....................see interface
light source.................................. 22
DC.................................. see power
default settings ................24, 25–29
depth of field
normal....................15, 16, 22, 29
reduced..................15, 17, 22, 29
M
E
maintenance ................................. 5
manual .......................................... 2
MetroSelect................................. 30
motor speed................................ 22
EMC ............................................36
EMI..............................................36
emissions ....................................36
N
F
notices ........................................ 37
flash...............................................1
O
H
operation..................................... 37
hole pattern ...................................6
40
INDEX
P
environmental.......................... 23
mechanical .............................. 23
operational............................... 22
Stand-Alone Keyboard see interface
storage........................................ 23
patents.........................................39
pin assignments
cable ..................................33–34
scanner....................................32
port..............................7–11, 18–21
power ..................2, 3, 7–11, 22, 23
PowerLink........................ see cable
protocol........................................24
T
tone......................................... 1, 12
transformer......................see power
troubleshooting ..................... 18–21
R
U
razz .............................see indicator
RMA ............................................38
RS232 ........................ see interface
RS485 ........................ see interface
UL .......................... see compliance
USB ............................see interface
V
S
ventilation.................................... 23
voltage .............................. 7–11, 23
volume ........................................ 12
safety.....................................35, 37
scan lines ....................................22
scan pattern.................................22
scan speed..................................22
scan zone.............see depth of field
serial emulation mode .................11
specification
W
warranty...................................... 38
weight ......................................... 22
white ...........................see indicator
window...................................... 4, 5
electrical...................................23
41
May 2008
Printed in the USA
0 0 - 0 2 2 8 2 D
|