Guarantee
Xpelair
UK: The fan is guaranteed against defects for 3 years from the date of purchase.
• Xpelair reserve the right to repair or replace the fan.
• Keep your purchase receipt.
Safety Extra Low Voltage
Centrifugal Ducted Fans
• Any problems, contact the address below.
Technical Advice & Service
UK: Xpelair have a comprehensive range of services including:
• Free technical advice Help-Desk from Engineers on all aspects of ventilation
• Free design service, quotations and site surveys
Outside UK: See International section below.
· LVDX200 Standard
· LVDX200T Timer
Please ask for details on:
Tel
Fax
+44 (0) 8709 000430
+44 (0) 8709 000530
Condensation Control Fans
Also at the address below
Head Office – UK Sales Office and Spares
· LVCF20 Pull Cord
Applied Energy Products Ltd, Morley Way, Peterborough, PE2 9JJ, England
Tel:
+44 (0) 1733 456789
+44 (0) 1733 310606
+44 (0) 8709 000420
+44 (0) 8709 000520
· LVCF20T Pull Cord/Timer
Fax:
Sales/Spares Hotline:
Sales/Spares Faxline:
Web:
Installation and Maintenance Instructions
Retain for future reference
International
Guarantee – Contact your local distributor or Xpelair direct
Technical advice and Service – Contact your local Xpelair distributor.
567-2069-01
Revision D
8
Download from Www.Somanuals.com. All Manuals Search And Download.
The transformer must also not be mounted Before making any adjustments, isolate the fan operating at high speed. Note: If the separate on/off
within 0.6m of a bath or shower cubicle, up to a completely from the mains supply, check switch and integral pull cord are both on, the lights
E
height of 2.25m.
specification below to see which features apply to “I” and “II” will both be lit and the fan will run at
high speed.
1. Remove the front cover and replace after Trickle feature on or off
The transformer must not be mounted where your fan.
ambient temperatures are likely to exceed 40°C.
adjustment (Fig. C).
This is set by the installer to provide continuous
background extraction, when the humidity level is
below that set by adjusting screw “RH”.
Fixing the transformer directly
LVDX200
1. Remove the two screws securing the cover,
remove cover.
2. Position the transformer on the wall, and mark
the two fixing holes.
3. Drill and plug the two holes and fix the
transformer with the screws supplied.
For loft mounting:
The transformer can be fixed to a wooden surface
with the two screws supplied.
For fixed surface wiring:
There are no user adjustments for the LVDX200 fan.
LVDX200T
LVCF20T only
Time delay stat feature on or off
1. The timer over-run period can be adjusted This is set by the installer to provide a 2-minute time
between approximately 30 seconds and 20 delay start when the fan is switched on using
minutes. Use an electrician’s screwdriver and separate on/off switch.
turn screw “T” (Fig. D), clockwise to increase
time, anti-clockwise to decrease. (Factory
preset to approximately 10 minutes).
a
Cleaning
1. Before cleaning, isolate the fan completely
Use the rectangular knockouts on each side (X).
These accept 25 x 16mm trunking (not supplied)
For concealed wiring:
from the mains supply.
2. Only clean the external surface of the fan,
using a damp lint free cloth.
3. Do not use strong detergents, solvents or
chemical cleaners.
4. Allow the fan to dry thoroughly before use.
5. Apart from cleaning, no other maintenance is
required.
LVCF20
1. The humidity setting is adjustable between
approximately 50% and 90% relative
humidity. Use an electrician’s screwdriver, and
turn screw “RH” (Fig. D), clockwise to
increase the relative humidity setting and anti-
clockwise to decrease. (Note: the fan is more
sensitive at 50% RH than at 90%).
Use the round knockouts (Y).
For connection to a window mounted fan:
Use knockout (Z). Use flexible cable.
When using the side entries with flexible cable, a
hole suitable for the cable size must be made
centrally in the rectangular section.
Key
See Diagram E
LVCF20T
Wire the Fan
1. The timer over-run period can be adjusted 1. Baffle Plate
between approximately 30 seconds and 20 2. Front Cover
minutes. Use an electrician’s screwdriver and 3. Impeller
turn screw “T” (Fig. D), clockwise to increase 4. Fixing Screws
time, anti-clockwise to decrease. (Factory 5. Terminal Cover
1. Isolate the electricity supply and remove all
fuses.
The terminal block will accept cable up to
1.5mm².
2. A means for disconnection in all poles must be
incorporated in the fixed wiring in accordance
with the wiring rules.
3. Use suitably rated 3-core or 4-core cable
dependent on application.
4. Remove the retaining screws of the terminal
preset to approximately 10 minutes).
6. Fan Box
2. The humidity setting is adjustable between 7. Circular Spigot
approximately 50% and 90% relative 8. Clamp screws and wall plugs– 3 off
humidity. Use an electrician’s screwdriver, and 9. Fan body clamps – 3 off
turn screw “RH” (Fig. D), clockwise to 10. Surround
increase the relative humidity setting and anti- 11. Ceiling screws 25mm long - 4 off (Diagram B)
clockwise to decrease. (Note: the fan is more 12. Foam Tape
cover •, if still in position.
5. Wire the fan as shown in F using the cable
clamp provided. Check fan model to diagram.
sensitive at 50% RH than at 90%).
PLEASE LEAVE THIS LEAFLET WITH THE
FAN FOR THE BENEFIT OF THE USER
LVDX200T: “LH”
=
Live (High Speed)
/
Using the Fan
“LL” = Live (Low Speed)
6. Replace the terminal cover • and fasten the
retaining screws.
7. See section on “User adjustments” if you wish
to use settings other than those that have been
factory set.
8. Refit the front cover • (Fig. C).
9. Connect the cable from the isolating switch to
electrical supply wiring, and re-check
installation.
10. Refit fuses before turning on electricity supply.
11. For fixed wiring circuits, the protective fuse
for the appliance must not exceed 5A.
Ancillary Options
LVDX200
Operate the fan using the external On/Off switch. For speed and ease of installation, your installation
Repeat to switch off. The fan speed is pre-set by the may require some of the Ancillaries listed below:
Installer to either high or low speed.
WD100
CFWG100
XCT100
DGW/B
SP100
XAA
VC10
WT10
XF/FM
Wall Duct
Wall Grille
Both speeds can be selected when wired through a
change over switch Part No. 90108AW.
Condensation Trap
Air Replacement Grille
Spigot Plate
Air Brick Adaptor
Vent Cowl
Termination Ducting Kit
Flat Ducting (Plastic/Metal)
(Plastic 234x29
Metal 230x25)
Wall Vent Kit
Flexible Ducting
Worm Drive Clips
Ceiling Mounting Kit
In-Line Back Draught Shutter
Easy Fit Termination Kit
Glass Mounting Adaptor
Grease Filter
LVDX200T
G
Operate the fan using the external on/off switch.
Repeat to switch off.
When the switch is turned off, the fan continues to
operate for the selected over-run timer period. Top
light “I” is lit when the external on/off switch is
For Australia Only
LVCF20 – Connection to the supply – flexible 3- turned on.
core cable with 3 pin plug top for insertion into an The fan speed is pre-set by the installer to either
approved 10A wall mounted surface switch with at high or low speed. (If a change over switch has been
VK10
FD100
WDC5
XCMK
XBP
least 3mm clearance between contacts.
ALL OTHERS Permanently connected to the speed and low speed.)
supply and a remote switch controls operation. They
installed then the user can switch between high
–
should be directly wired to the supply through an Time delay start feature on or off
approved 10A wall mounted surface switch with at This is set by the installer to provide a 2-minute time
least 3mm clearance between contacts.
EFT
GMK
PDXGF
FDA
delay start when the fan is switched on using the
external on/off switch.
Wire the Transformer
Flat Duct Adaptor Kit
LVCF20 / LVCF20T
Always wire via the cable clamp.
1. Remove the cable clamps.
2. Wire the transformer as shown in F. Check the
fan model to diagram.
Spares
Switched Operation
The fan can be wired with a separate on/off switch.
Fan operates at condensation speed when switched
Listed below are some of the spares available. See
back page of this booklet for ordering details:
on. Top light “I” is lit when the separate on/off 41756SK
switch is switched on. When switched off, the fan 41757SK
will continue to operate if the humidity level has not 41758SK
reached that set by adjusting screw “RH”. 41759SK
LVCF20T only: When switched off, the fan 41760SK
continues to operate for the adjustable timer over- 41769SK
run period.
Motor (LVDX200T)
Motor (LVCF20/LVCF20T)
PCB Assy. (LVDX200T)
PCB Assy. (LVCF20)
PCB Assy. (LVCF20T)
Front Cover c/w Baffle
(LVDX200T)
Front Cover c/w Baffle
(LVCF20 / LVCF20T)
Surround Moulding
(Entire Range)
3. Ensure all connections are tight.
4. Replace the clamps and two screws. Ensure the
cable is firmly retained by the clamp.
5. Replace the transformer cover with the two
screws.
6. Switch off the mains electrical supply and
remove fuses.
7. Connect the cable from the isolating switch to
Condensation Operation
41770SK
The fan operates at condensation control speed,
when the relative humidity exceeds the set level, and 41740SK
turns off when the humidity drops.
the electrical supply wiring.
8. For fixed wiring circuits the protective fuse for
the appliance must not exceed 5A.
Boost Operation
41741SK
Pull-Cord Assembly
(Entire Range)
User adjustments
The integral pull cord switch switches the fan to run
at high speed. Bottom light “II” is lit when the fan is 41742SK
Impeller (Entire Range)
6
3