APPLICATION  
WARNING  
!
This regulated Natural Gas to unregulated L.P. Gas conversion  
kit allows the 36C, 36E and 36J Series gas valves to be used  
on L.P. gas applications, PROVIDED an external regulator is  
used and the inlet pressure does not exceed 14W.C. This  
conversion kit is for use on all single stage, fast and slow  
open models only.  
This conversion kit shall be installed by a qualified  
service agency in accordance with the manufacturer’s  
instructionsandallapplicablecodesandrequirements  
of the authority having jurisdiction. If the information  
in these instructions is not followed exactly, a fire, ex-  
plosion, or production of carbon monoxide may result,  
causing property damage, personal injury, or loss of  
life.The qualified service agency performing the work  
assumes the responsibility for the proper conversion  
of this appliance with this kit.  
TO CONVERT FROM NATURAL TO L.P. GAS  
1. Remove regulator cover screw.  
2. Insert the spring (provided in the conversion kit) through the  
hole in the center of the plastic regulator adjustment screw.  
3. Insert the blocking pin (provided in the conversion kit) down  
into the center of the spring.  
Regulator  
Cover Screw  
4. Replace the regulator cover screw.  
5. AttachtheWARNINGlabel(providedinthekit)tothegasvalve  
where it can be readily seen. Also attach the small round L.P.  
label to the top of the regulator cover screw.  
Blocking Pin  
Spring  
Plastic Regulator  
Adjustment Screw  
6. If present pilot burner is to be used, the pilot orifice must be  
replaced.  
ConversionbacktoNaturalGasusemaybemadeatalaterdate  
by removing the spring and blocking pin (installed in steps 2 and  
3, above) and removing the WARNING and L.P. labels.  
Figure 1. 36C model  
! WARNING  
Regulator Cover  
Screw  
VALVE CONVERTED FOR USE ON L.P.  
GAS. REGULATOR BLOCKED OPEN.  
EXTERNAL REGULATOR REQUIRED.  
IMPROPER OPERATION COULD RESULT  
IN DEATH OR SERIOUS INJURY.  
Regulator  
Cover Screw  
Blocking Pin  
Spring  
!
MISE EN GARDE  
SOUPAPE CONVERTIE POUR USAGE  
SUR GAZ DE PÉTROLE LIQUÉFIÉ.  
RÉGULATEUR BLOQUÉ EN POSITION  
OUVERTE. RÉGULATEUR EXTERNE  
NÉCESSAIRÉ. UN FONCTIONNEMENT  
INAPPROPRIÉ PEUT PROVOQUER LA  
MORT OU DES BLESSURES GRAVES.  
Blocking Pin  
Spring  
Plastic Regulator  
Adjustment Screw  
WARNING Label  
Plastic Regulator  
Adjustment Screw  
Spring  
LP  
L.P. Label  
Blocking  
Pin  
Figure 4. Contents of kit  
Figure 3. 36J model  
Figure 2. 36E model  
PART NO. 37-5382E  
Replaces 37-5382D  
0943  
White-Rodgers is a division  
of Emerson Electric Co.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Wegener Communications Home Theater Server DTV742 User Manual
Weider Home Gym 28ST User Manual
Westinghouse Flat Panel Television DWM40F1A1 User Manual
Westinghouse Flat Panel Television eu40f1g1 User Manual
Whirlpool Range 98015195 User Manual
Whirlpool Refrigerator 2211602 User Manual
Wolf Indoor Furnishings STAND C 48 User Manual
Woods Equipment TV Mount BH6500 User Manual
Zanussi Washer FCS 1020 C User Manual
Zephyr Ventilation Hood ZSA E30BB User Manual