WhisperKOOL
XLT
Owner’s Manual
Protecting Your Investment In Fine Wines
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . .2
What Is the WhisperKOOL® System?..................2
How Does the WhisperKOOLSystem Work? .............2
Receiving and Unpacking .....................3
Quick Start Guide............................4
Preparing the Wine Cellar ....................5
Mounting the Unit ..............................6
Ventilation ...................................7
Cutting the hole for the WhisperKOOL unit .............8
Installation ................................10
Electrical Needs ..............................11
Sizing Unit to Room ............................11
Placement of Unit ..............................13
Drain Line ................................13
Liquid Measuring Thermostat System.......14
PDT JR. Operating Instructions ............15
Installing Thermostat ............................13
Using the WhisperKOOL System ..............13
Condensate Evaporator Switch ....................13 PDT Operating Instructions................16
Normal Operation.........................17
Maintenance...............................17
Humidity Control ............................17
Troubleshooting Guide ....................18
Solutions to Common Problems ..................18
Troubleshooting Checklist .................23
Temperature Differential Testing...........25
Technical Assistance .....................28
How to Contact Customer Service.................28
Warranty Clarification .....................29
Limited Warranty ...........................31
NEW OWNERS PLEASE NOTE…
ALWAYS PLACE UNIT IN UPRIGHT POSITION
Do not start or plug-in your new unit for 24 hours after delivery. . .
Units are sometimes accidentally tipped onto their sides during
shipping which may allow compressor oil to escape their
reservoirs. . .
Premature starting—before the oil has had a chance to
resettle—can cause damage to the compressor and result in a lack
of cooling.
A DEDICATED 20 AMP CIRCUIT IS HIGHLY
RECOMMENDED FOR OPTIMUM OPERATION!
-1-
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Thank you for purchasing the WhisperKOOL® wine cellar temperature and
humidity maintenance system.
Please take the time to read through the owner's manual so you understand
the correct operations of the WhisperKOOL unit.
What Is the WhisperKOOL System?
The WhisperKOOL system is a specialized piece of equipment designed to
absorb heat from a cellar and discharge it through the rear of the unit into
an adjacent room. The unit will operate 75 to 80 percent of the time in
order to maintain an ideal temperature and humidity in a wine cellar.
Essentially, it will operate as needed to absorb the heat that naturally
permeates the cellar. It is important to follow the cellar construction guides
provided within in order to maximize effectiveness based on the quality of
efficiency in the vapor barrier, therefore reduce the operating time of the
cooling unit itself.
How Does the WhisperKOOL System Work?
• The WhisperKOOL system is designed to maintain humidity, while
measuring and maintaining the wine temperature in the cellar. This is
achieved by gently cooling rather than by quick-chilling.
• Temperature Setting: The WhisperKOOL unit can be set at any
temperature within the acceptable wine-aging range of 50°F -to- 70°F. It is
designed to cool 30°F cooler than the ambient temperature of the space it
is exhausting to.
• Humidity Control: There are no separate controls for maintaining proper
humidity. Humidity is managed through the design and engineering of the
unit. As the temperature begins to drop within the wine cellar, the relative
humidity will rise, while the absolute humidity will stay the same. For more
information about this process, see Normal Operation on page 17.
All units come with a drain line for additional removal of excess condensate,
as a back up system to the Condensate Evaporator which is used to maintain
proper humidity. If the unit is installed in a high humidity area of the country,
it is mandatory to install the drain line attachment for the unit to function
effectively, preventing overflows and leaks from build up of condensate.
Failure to install the drain line voids warranty.
• The WhisperKOOL system is designed to be mounted through an interior
wall into the cellar. The unit will operate correctly in a controlled
environment to properly manage the effective cooling of the cellar. The unit
is not designed to withstand the elements of an outdoor climate where
summer temperatures exceed 85 degrees or in winter environments where
temperatures reach freezing. The components are not designed for these
extreme conditions and premature failure may occur.
Note: Improperly preparing your enclosure or incorrectly installing your
WhisperKOOL system may cause unit failure, leaking of condensation, and
other negative side effects. Protective housings can be purchased to prevent
premature failure in cases where the unit is installed through an exterior
wall.
-2-
Download from Www.Somanuals.com. All Manuals Search And Download.
RECEIVING AND UNPACKING
Please examine the WhisperKOOL packaging for any damage
to the carton. Note any damage on the bill of lading, shipper’s
receipt, or airbill. Damaged merchandise should be accepted.
Contact Vinothèque Customer Service immediately.
Do not attempt to install any unit with cosmetic damage. This
includes (but is not limited to) bent flange and/or brackets. A
representative will file a claim with the shipping company,
arrange for a replacement unit to be shipped to you and for the
original unit to be picked up. In some instances, an inspection
must take place at the point of receipt, in which case you will
be contacted by the shipping company to schedule an
appointment to inspect the damaged goods.
Please leave the WhisperKOOL System in its original box until
you are ready for installation. This will allow you to move the
product safely without damaging it. When you are ready to
remove the product from the box, see Installation on page 10.
Note: Save your box and all packing materials. They
provide the only safe means of transporting the unit.
Contents:
• Owner's Manual
• By-Pass Plug
• Registration/Warranty Card
• Insulation Foam (4 strips)
• 8 - 1 3/4" Screws (18 for WK 6000 & 8000)
• Power Cord
• Drain Line
• Thermostat
-3-
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK START GUIDE
This guide is meant to serve as a quick reference for installation of the
WhisperKOOL unit. The remainder of this Owner’s Manual will provide more
detailed information and instructions.
Upon receiving the WhisperKOOL unit:
1. Inspect the unit before installation. If damage is found, please contact your
distributor or Vinothèque Customer Service at 1.800.343.9463 ext 799.
2. The unit should remain in an upright position for 24 hours prior to
operation.
3. The unit is designed to gently cool down the temperature of the cellar over
time by cycling cooler and cooler air throughout. Test the unit prior to
installation. With power off, attach the “by-pass plug” (included in accessory
bag) to the open plug located on the unit, where the PDT thermostat will need
to be installed. Operate unit for twenty minutes. While the unit is running and
working properly, the air discharged from the front should be 10 - 15°F
cooler than the air in the room. This means that in an environment where
the air is 80°F, the unit will discharge air that is 68°F.
4. The WhisperKOOL unit requires a dedicated 110-volt 20-amp circuit (or 220-volt
depending on the unit). Use a surge protector with the WhisperKOOL unit. Do not
use a GFI (Ground Fault Interrupter) line.
5. For your convenience, the Whisperkool unit has two power sockets, one on the
side of the unit and the other on the back. Both sockets come covered. Remove
the cover from only the desired power socket in order to plug the unit in.
6. After testing, remove the “by-pass plug,” mount unit to desired location, and
install the PDT thermostat into the plug. There is a five (5) minute delay on
initial start up of the unit.
7. In areas of high humidity, put the condensate evaporator switch to the
“ON” position. It is also necessary to install the drain line to remove excess
condensation from the unit.
8. The WhisperKOOL unit is intended for use in properly designed and
constructed wine cellars. Hire a professional wine storage consultant with a
valid contractor’s license to build your wine cellar. Refer to the “How to Build a
Install the foam strips along the inside edge of the unit’s flange to assure a
proper seal against the wall.
Never try to open the WhisperKool unit, repair it yourself, or use a
service company without Vinothèque’s authorization. This will void your
warranty.
If you encounter a problem with your WhisperKool unit, please refer to the
Troubleshooting Checklist on pages 23-26. If you have any further questions,
concerns, or need assistance, please contact Vinothèque Customer Service at
1.800.343.9463 ext. 799. Please be sure all testing has been completed prior to
contacting Customer Service. Please have your results ready for your
representative.
-4-
Download from Www.Somanuals.com. All Manuals Search And Download.
PREPARING THE
WINE CELLAR
The performance and life of your WhisperKOOL System are contingent upon the steps you
take in preparing the wine cellar.
It is highly recommended that you obtain the assistance of a wine
storage professional.
Wine storage professionals work with licensed contractors, refrigeration technicians, and
racking companies to build well-insulated, beautiful, and protective wine cellars. In some
areas of the country, these professionals are not available. We have put together some
useful tips to assist in the installation process.
Our recommendations are meant to act as a guide in the process of building a proper
enclosure. Your intended location may have specific needs that we do not address.
Wall & Ceiling Framing
Build wine cellar walls using standard 2x4 or 2x6 construction methods and ceiling joists
following the guidelines of local and state codes in your area. The general rule for a cellar
is the thicker the walls, the higher the insulation factor, the better the cellar remains at a
consistent temperature.
Insulation
Insulation is REQUIRED with the use of the WhisperKOOL product; Standard “Fiberglass”
or “Rigid Foam” insulation is normally used in cellar construction, or in some cases,
“blown in” insulation is used. It is very important that all walls and ceiling be insulated to
keep the cellar temperature as consistent as possible during the summer and winter months.
The R factor or thickness of insulation is determined by the thickness of the walls and
ceiling. For example, fiberglass insulation of R13 is designed to be used in a 2x4 wall.R19
is used in a 2x6 wall. It is important to use the correct insulation for the wall thickness.
Vapor Barrier
Vapor barrier is REQUIRED if a climate control cooling unit is installed to keep the cellar at
the correct temperature and humidity. 6mm plastic sheeting is applied to the warm side of the
cellar walls.The vapor barrier must be either applied to the outside walls and ceiling, or if it
is impossible to get to the outside, then the plastic must be applied from within the cellar. The
most common method is to wrap the entire interior, leaving the plastic loose in the stud cavity
so the insulation can be placed between each stud. All walls and ceiling must be wrapped in
plastic for a complete vapor barrier.
In areas of humidity, such as the southern and gulf states, the vapor barrier will prevent
infiltration of warm moist air. The moist air can cause mold to form. The cooling unit will strip
excessive moisture from the air and create water, which will need to be dissipated back out
of the cellar using the Condensate Evaporator system or drain line. In dry climates, the vapor
barrier will provide more control over retaining the higher correct humidity within the cellar.
Ducting
The unit is designed to exhaust into an open area. In situations where ducting may be
necessary, Vinothèque Wine Cellars provides a specially designed ducting accessory kit for
the XLT unit. Please contact Customer Service to order the ducting accessory kit by phone
(800) 343-9463. Using any other ducting system voids warranty. Sheet rock must be
applied in the exhaust room with no vapor barrier or insulation exposed. Failure to
complete the wine cellar voids the warranty.
-5-
Download from Www.Somanuals.com. All Manuals Search And Download.
Unobstructed Airflow
Mounting the Unit
Unobstructed airflow to and from
the unit is a critical factor in the
unit’s overall performance.
Make sure there is a three-
foot horizontal clearance in the
front of the unit. This will assure
that the unit can move the air
around in an efficient manner.
Avoid the attempt to camouflage
the unit by installing racking in
front of the unit. This will restrict
airflow and thus the unit’s ability
to work efficiently.
The unit should be mounted
within 18 inches of the top of
the room in order to achieve
sufficient cooling. As the room
cools down, the warm air will
rise to the ceiling. Mounting the
WhisperKOOL high in the room
will create a consistently cool
environment by capturing the
warm air and replacing it with
cool air. Mounting the unit low in
the room will result in
a
temperature variation in the
room due to the unit’s inability to
draw warm air from the ceiling of
the cellar to the unit itself.
Exhaust Room
Exhaust
Intake
Front of
WhisperKOOL
Wine Cellar
Door
An exterior grade (1 3/4”) door must be installed as a cellar door. It is very important that weather stripping
is attached to all 4 sides of the doorjam. A bottom “sweep” or threshold is also required. The door must have
a very good seal to keep the cool cellar air from escaping out of the cellar. One of the most common problems
with cooling units running continually is due to the door not sealing properly. In cases where glass doors are
used and the room size is close to the recommended unit size, the next larger size WhisperKOOL should be
used. This will compensate for the insulation loss due to the inefficient door.
-6-
Download from Www.Somanuals.com. All Manuals Search And Download.
Ventilation
Ambient Temperature Factor
The necessity of dissipating heat away
from the unit is critical to the unit’s
performance and cannot be overstated.
As the unit operates and cools, a greater
amount of heat is generated on the
exhaust side of the unit. Adequate
ventilation is required in order to
dissipate heat away from the unit. If
ventilation is inadequate, the exhaust will
heat up and adversely affect the unit’s
ability to cool. In some cases, it may be
advisable to install a vent fan to dissipate
heat within the exhaust area on the
backside of the unit. However, you must
have a fresh air inlet as well. If your unit
requires ducting, please contact
Vinothèque Wine Cellars Customer
Service to obtain a specially designed
ducting accessory kit for the XLT unit.
Using any other ducting system voids
warranty.
The cooling system has the ability to cool a
maximum of 30°F below the ambient
temperature in the room it is exhausting
to. Therefore you want to exhaust the unit in
a room which will not exceed 85°F.
Otherwise the unit will not have the
capacity to keep the wine at a desirable
55°F.
Unobstructed Airflow
Unobstructed airflow to and from the unit
is a critical factor in the unit’s overall
performance. Make sure there is a
minimum three-foot horizontal clearance
from the rear of the unit as well as a
minimum three foot clearance in front of
the evaporator fans. This will assure that
the unit can move the air around in an
efficient manner.
Back - Exhaust Room
Front - Wine Cellar
WhisperKOOL
Exhaust Fan
(side view)
85ºF
55ºF
Cellar Wall
Air Intake
-7-
Download from Www.Somanuals.com. All Manuals Search And Download.
Cutting the hole for the WhisperKOOL
unit
Tools Needed
Locate the center of the room. Using a
stud finder, locate two adjacent studs in
the walls, and mark them with vertical
lines.
Using a level and a pencil, mark a
horizontal line on the wall between the
two studs, approximately 1.25 inches (or
as close as possible if more than 1.25”)
from the ceiling. Using a ruler or
measuring tape, measure 16 inches down
(22.75” for the 6000 and 8000 models),
and mark another horizontal line parallel
to the first one.
Phillips
Screwdriver
Saw
Level
Hammer
Mark the horizontal
lines with a level.
Using a saw, cut along the uppermost
horizontal line until your saw reaches the
stud. Turn the saw around, inserting it
into the cut you have just made, and cut
toward the opposite stud so that you have
a clean horizontal cut between the two
studs. Be careful not to cut into the studs
themselves. Now make the second
horizontal cut from stud to stud on the
line 16 inches below the first cut (22.75"
for the 6000 and 8000 models).
Cut horizontal
lines from stud to
stud.
-8-
Download from Www.Somanuals.com. All Manuals Search And Download.
Once the horizontal lines have been cut,
make vertical cuts using the inside edge
of the studs as a guide. Once you have
made both vertical cuts, you should have
a rectangular hole in the sheetrock. Now
you have to make the same hole on the
other side of the wall. Since you already
have one hole, this is an easy process.
Using a nail, mark all four corners of the
first hole by making nail holes through the
sheetrock. Then on the other side of the
wall, connect the holes with a pencil mark
and cut.
Sheetrock alone cannot support the
weight of a 65-pound (or more) cooling
system. Therefore, it is necessary to
frame the hole that you have just cut with
upper and lower supports. Using two two-
by-fours 14.5 inches in length and eight
6d nails, secure the upper and lower
supports to the right and left studs, just
inside the sheetrock. Make sure that the
internal height remains at 16"for the
1600, 3000 and 4200 models and 22.75"
for the 6000 and 8000 models so that the
WhisperKOOL system will fit snugly
through the framed cut-out.
Cut vertical lines
along the inside
edge of the studs.
Frame the hole with
two-by-four supports.
-9-
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Electrical Needs
The WhisperKOOL System requires a dedicated 110-volt 20-
amp circuit. The unit draws a large amount of amps at initial
start up. By designating a dedicated circuit breaker, you will
guarantee the unit has enough power to run effectively.
Contact your electrician for installation of this dedicated
electrical circuit.
Electrical Outlet
The unit is equipped with two electrical outlets, one for
installation inside the cellar and the other for installation
outside the cellar. Both outlets are covered and have been
secured with screws. Regardless of which side is utilized, the
other outlet must then be covered in order to avoid a live
electrical charge.
Purchase a surge protector or power conditioner to plug
your WhisperKOOL unit into. As with any sensitive
electrical equipment, the WhisperKOOL unit’s circuitry
may be damaged by power surges and spikes. Power
surges and spikes are not covered by the WhisperKOOL
warranty.
Do not use a Ground Fault Interrupter (GFI) with this
product. The cooling unit will draw more amperage
than the GFI will allow.
Upon plugging the unit in and turning it on, there will
be a five minute delay before the unit starts. This is
based on the function of the thermostat.
Sizing Unit to Room
The specification chart will provide information on the unit’s room size cooling capacity.
There are circumstances in which a cellar design may require a larger unit due to some
existing design restrictions. In such a case, we recommend that the customer consider
purchasing a unit with a larger capacity to compensate for the design limitations. Issues
such as glass doors, concrete, or brick walls and floors may seem adequate but do not offer
the insulation capacity required to maintain the optimum environment.
MODEL
AMPS
AMPS
PRODUCT DIMENSIONS
(H x W x D)
ROOM SIZE
(cubic feet)
300
(starting) (running)
WK 1600
WK 3000
WK 4200
28.32
30.00
32.00
4.5
6
15.75" x 14.25" x 17"
15.75" x 14.25" x 17"
15.75" x 14.25" x 17"
650
9
1000
WK 6000
WK 8000
36.00
36.00
9.5
10
22.5" x 14.25" x 21.25"
22.5" x 14.25" x 21.25"
1500
2000
-10-
Download from Www.Somanuals.com. All Manuals Search And Download.
Carefully remove your WhisperKOOL unit
from the box. Do not destroy your packing
material, as it provides the only safe
means of transporting the unit. Units
weigh 65–100 pounds and are
cumbersome for one person to carry. We
recommend that you get someone else to
help you during the installation process.
Testing Unit
Place the WhisperKOOL system on a
tabletop to prepare it for installation and
testing. Locate the by-pass plug and
insert it into the thermostat plug, located
on the front of the WhisperKOOL System.
Next, plug the system into a live electrical
outlet and turn the unit on. The system
should begin cooling. The system may
take up to 10 to 15 minutes before
running cool. Once the operation has
been tested, turn the unit off, unplug the
unit from the electrical outlet, remove the
by-pass plug, and install thermostat.
Test Plug
Before installation, use the by-pass test plug
to test the unit.
Note: If the system does not seem to be
running cool after 15 minutes, please
refer to the Troubleshooting Guide on
page 18.
Applying Insulation Tape
Adhesive Covering
Foam Tape
Locate the four precut pieces of black
foam tape included with your system.
There should be two larger pieces and two
smaller pieces. Start with the large
pieces. Peel back the white-paper
adhesive covering, and attach the large
pieces to the sides of the unit flange. Then
follow with the two smaller pieces on the
top and bottom. This foam creates a tight
seal between the unit’s flange and the
wall (see illustration).
Flange
Note: Failure to install foam strips may
void the warranty.
Attach precut foam tape to the unit’s flange.
-11-
Download from Www.Somanuals.com. All Manuals Search And Download.
Placement of Unit
Electrical Outlet
Slide the unit from the outside wall into
your wine cellar with the outer flange
flush to the outside wall. Secure the
flange to the wall through the predrilled
holes. The screws should penetrate the
studs as well as the upper and lower
supports to provide adequate support
for the WhisperKOOL System (see
illustration). Seal all cracks and gaps
around the WhisperKOOL unit with
caulking to prevent air leakage. (If you
use molding, it should be attached to
the walls, never to the WhisperKOOL
unit itself.)
The unit is equipped with two electrical
outlets, one for installation inside the
cellar and the other for installation
outside the cellar. Both outlets are
initially covered and secured with screws.
Select the outlet to be used and remove
that cover; the unused outlet must remain
covered to avoid live electrical charge.
Remove side electrical outlet cover for
easy through the wall installation.
Immediately replace cover when install is
completed and prior to powering up unit
if electrical cord is not attached to outlet.
Two-by-Four Upper Support
Wall Stud
Wall Stud
2” x 4”
Lower Support
Drain line
Electrical Outlets
Slide unit into your cellar, and secure all
screws firmly to the studs and supports.
Installing Thermostat
Attach the thermostat to the front of the
unit using the mounting bracket. Make
sure the black male plastic plug from the
unit is securely fitted into the female plug
located on the circuit board of the
thermostat. To complete the installation,
insert the small black screws into each
side of the thermostat PDT/PDT Jr.
securing it to the mounting bracket.
Insert the probe into a wine bottle 3/4 full
of water.
Attach the PDT mounting bracket.
Attach the PDT to the mounting bracket.
-12-
Download from Www.Somanuals.com. All Manuals Search And Download.
USING THE WHISPERKOOLSYSTEM
Drain Line
Power Switch
All units come with a drain line for
The new series WhisperKOOL units come
equipped with an On/Off switch. The
On/Off switch is simply used when the
owner does not need to utilize the
equipment. Placing the power switch to
the front position allows power to flow to
the side outlet. Placing the switch in the
rear position allows power to flow to the
rear outlet.
additional
removal
of
excessive
condensate. This is a back up system to
the Condensate Evaporator. If the unit is
installed in a high humidity area of the
country, it is mandatory to install the
drain line attachment. In high humidity,
the cooling unit will strip excess water
from the air in order to maintain the
proper level of humidity within the cellar.
The Condensate Evaporator will heat and
dissipate the excess moisture through the
rear of the unit. However in extreme
humidity, additional condensate will be
created. Conversely the high humidity air
has less capacity to absorb additional
moisture through the exhaust of the unit.
Thus the drain line will prevent overflow
and leaking by allowing for discharge of
the additional condensate. Failure to
install the drain line voids warranty.
NOTE; (It will take five minutes before
the unit begins to operate once the
switch is placed in the “On” position. This
is due to the designed safety delay in the
PDT thermostat.)
Condensate Evaporator Switch
The Condensate Evaporator is a heating
element that automatically evaporates
excess condensate that accumulates in the
cooling system as a by-product of
refrigeration. Like most cooling systems,
WhisperKOOL uses heat from the
compressor to evaporate and eliminate the
majority of the water that accumulates
during normal use. However, during
certain weather conditions or in humid
areas (above 80%), more condensate will
accumulate than the cooling system can
evaporate with heat from the compressor
alone. Only the WhisperKOOL units are
equipped with sophisticated heating
elements that automatically sense the
presence of water and work continually
until the water is gone
Setting the Condensate Evaporator to the
“On” setting causes the heating element
and the right exhaust fan to stay on
¤
continuously
to
prevent
excess
condensation from building up in the unit.
Switches
Location of control switches
-13-
Download from Www.Somanuals.com. All Manuals Search And Download.
LIQUID MEASURING THERMOSTAT
SYSTEM
All WhisperKOOL units come equipped
with our Precision Digital Technology
(PDT/PDTJR) liquid temperature measuring
To Use the thermostat:
1. Locate an empty wine bottle.
thermostat
system.
This
system
2. Fill 3/4 full with room temperature tap
water.
incorporates the following advantages:
1. Self-Calibrating Probe: The probe
contains a sensor chip, which actually
communicates back and forth to the
thermostat. This results in a consistent
temperature setting and accuracy. Do
not remove the tip from the probe!
3. Place bottle probe securely into bottle.
4. Place bottle with probe level and to the
side of the unit in your wine cellar.
Avoid pulling too much on the probe cord.
It may become disconnected resulting in
non operation of the unit.
2. Built in Defrost Cycle: The unit is
designed to shut off for five minutes
every ninety minutes in order to prevent
frost build up. This allows the cooling
unit to continue to cool effectively in
demanding environments. A count down
timer is observed by depressing the
center button on the thermostat. (PDT
upgrade version only)
Note: Thermostat can be set between 50°F
and 76°F.
Remember: The WhisperKOOL System is
based on the temperature of the water.
Do not be misled by thermostats reading
air temperature. The air temperature in the
cellar will be cooler than the liquid
temperature of the water while it is coming
to optimum balanced temperature.
3. Heavy-duty Circuitry: The circuitry
within this new unit has been upgraded
to resist power surges, which play
havoc on electrical components. This
improvement will ensure years of
trouble-free use. However, for high
reliability, we still recommend that the
customer install a surge protector for
the unit itself.
Room-
temperature
4. Fahrenheit and Celsius Readout (PDT
upgrade version only): The thermostat
has the ability to produce the readout in
both Fahrenheit and Celsius for
overseas customers. The readout can be
changed by depressing both the center
and right buttons at the same time.
Measuring liquid temperature has a few
unique advantages:
1. Wine temperature is kept in a very
precise controlled environment. This
assures a consistent temperature.
Fill an empty bottle with room-temperature
water; then insert the probe.
2. By measuring the liquid temperature
rather than air, the unit will operate 75-
80% of the time. See page 2.
-14-
Download from Www.Somanuals.com. All Manuals Search And Download.
PDT JR OPERATING INSTRUCTIONS
Operating Instructions for Vinothèque PDT JR. Thermostat
Indicators
There are three colored lights on the left side of the thermostat:
• PWR (Green) – When this light is on, the unit is powered.
• RUN (Yellow) – When this light is on, the compressor is
running. If the light is flashing, the unit is currently in the five-
minute lockout.
• SET (Red) – This light flashes when the set-point
temperature is changed by pressing one of the three control
ꢀ
buttons (see below). It flashes once for each press of the ( ) or
ꢁ
( ) button, and twice when the 55 button is pressed.
When the unit is first turned on, all three lights flash slowly
while the thermostat starts up. Once the unit completes its
start-up check, the compressor is locked out for five minutes.
During this time the RUN light will be flashing slowly (1 flash
per second).
All three lights will flash rapidly if there is no probe connected
to the thermostat.
Buttons
ꢀ
ꢁ
To change the set-point temperature, press either the ( ), ( ) ,
or (55) buttons. The SET light will flash once for each 1°F the
set-point is changed. This set-point will remain in memory until
you change it.
If you forget where the unit is set, pressing the (55) button will
reset the set-point to 55°F and the SET light will flash twice.
The temperature cannot be adjusted below 50°F or above 76°F.
Attempting to set the unit outside this range will cause the SET
light to rapidly flash.
Operation
Whenever the compressor shuts off normally, a five-minute
lockout period begins and the RUN light will be flashing slowly
(1 flash per second).
If the compressor runs for 90 continuous minutes, a five-
minute defrost cycle is forced, during which time the
compressor will not run. During this defrost cycle the RUN light
will be flashing rapidly (2.5 flashes per second).
-15-
Download from Www.Somanuals.com. All Manuals Search And Download.
PDT OPERATING INSTRUCTIONS
The unit is set at 55°F at the factory. To raise or lower the set
temperature, press the set button while at the same time
pressing either the arrow up or arrow down button.
1
WINE Temperature Indicator
2
LED Screen
3
Wine Temperature Reading
WINE
ON
SET
PDT
Precision digital Technology Thermostat
55F
Temperature
SET
4
7
8
Temperature SET Indicator
Button
UP Arrow Button
DOWN Arrow Button
5
6
SET Temperature Button
Unit ON Indicator Button
1. Wine Temperature Indicator: A red LED bar will light up when
the thermostat is reading the liquid temperature in the bottle via
the probe. This will remain lit and the temperature you see
displayed is what the probe is reading.
2. LED Screen: Displays your thermostat readings.
3. Wine Temperature Reading: The temperature the water bottle
is registering to the thermostat.
4. Temperature SET Indicator: A red LED bar will light up when
you are setting the temperature.
5. Unit ON Indicator: A red LED bar will light up every time the
unit turns on to run a cooling cycle.
6. SET Button: Used to set the temperature you want the unit to
maintain.
7. UP Arrow Button: Used with the SET button to set temperature
higher. In addition, by pressing and holding the button it will
allow you to see the 5-minute count down.
8. DOWN Arrow Button: Used with the SET button to set
temperature lower.
*Up and Down Arrow Buttons used simultaneously will
change the temperature read out from Fahrenheit to
Celsius*
-16-
Download from Www.Somanuals.com. All Manuals Search And Download.
NORMAL OPERATION
WhisperKOOL systems are designed to maintain both
temperature and humidity. Once the system is installed and the
temperature set, it will run continuously until the wine cellar
is at your set wine temperature. This may be as much as three
weeks, depending on the size of the room, the quality (R-value)
of insulation, the original temperature of the wine, and the
number of bottles residing in the cellar. Once the cellar has
achieved the set temperature, the WhisperKOOL unit will cycle
to maintain 0.5°F of your set temperature.
The WhisperKOOL system will run more often than a
refrigerator or air conditioner, due to its gentle cooling
and humidity maintenance.
People often make the mistake of comparing the performance
of refrigerators with the performance and cycling of wine
storage equipment. Wine cellar cooling systems are highly
specialized and designed for one purpose only–long term
storage of wine.
Maintenance
The following maintenance should be performed on your
WhisperKOOLunit at least once every six months to promote
longevity and optimal performance.
Vacuum the back and front of the WhisperKOOLunit to clean
the coils and prevent air blockage. The condenser coils reside
behind the grill on the back of the WhisperKOOLunit. Don’t try
to open the unit itself. Just vacuum the surface of the grill
and remove any lint or dust that has accumulated.
Humidity Control
There are no separate switches in order to maintain humidity.
The cooling unit is designed to maintain relative humidity at
50-70%.
The WhisperKOOL units do not create humidity. If you live in a
dry area of the country you many need to create humidity in the
wine cellar. This can be done by introducing a non-heat
humidifier, or installing a small fountain within the cellar.
The back side of a
WhisperKOOL unit.
Intake Grill
Drain Line
-17-
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING GUIDE
Before contacting Customer Service regarding a performance issue with your cooling unit
(does not cool, leaks, ices up…), please review the following troubleshooting information and
complete the Troubleshooting Checklist found on page 23. It is designed to help you identify
the issue yourself and provide appropriate advice to remedy the issue or problem.
If you are unable to identify or solve the issue after completing and following these steps, fax
a completed Troubleshooting Checklist to Vinotheque Customer Service at 209.466.4606. The
checklist will provide Customer Service with background information on your cooling unit
installation and wine cellar to better assist you in resolving the issue. Be sure to include
accurate contact information
Problem
Likely Cause
Remedy
The unit does not
cool the room
Inadequate door seal
See “Door Seal” section on pg. 20
Improperly mounted unit
Unit has inadequate ventilation
Foam strips are not attached
See “Unit Mounting” section on pg. 20
See “Airflow” and “Ventilation” sections on pg. 19
See page 11 (in the “Installation” section)
Water leaking
from the rear
Condensate Evaporator is not
properly set for local climate
Drain line is not attached
See Water Leaking, Rear in the
“Condensation” section on pg. 21
See “Drain line” section on pg. 21
Unit is icing up
Thermostat is faulty
Unit is low on refrigerant
See “Thermostat” section on pg. 20
See “Icing Up” section on pg. 21
Unit isn’t running
Problem with local electrical
See “Power Requirements” section on pg. 21
or makes intermittent circuit
clicking noises
Try this first!
Clean off any accumulated dust, lint, or other debris from the front and rear
intake grills. This will restrict the airflow and may affect the unit’s ability to
function properly. Periodically cleaning the unit’s vents will help assure
maximum cooling efficiency.
Airflow
Proper airflow is critical to the performance of the WhisperKOOL unit. Any
obstruction to the intake and exhaust ports on either side of the unit will
compromise the unit’s ability to cool. Make sure the WhisperKOOLunit fan vents
are clear. Check the front and rear intake vents for any possible obstruction.
There should be a minimum clearance of three feet directly in front of the intake
and exhaust vents.
-18-
Download from Www.Somanuals.com. All Manuals Search And Download.
Ventilation
In order to determine if ventilation may be
the problem, try the following tests listed
on page 25.
Proper ventilation of the WhisperKOOL
unit is one of the most important and
often overlooked issues associated with
the unit’s performance.The WhisperKOOL
unit does create a large amount of heat,
which needs to dissipate away from the
unit freely in order to cool correctly. This
issue is sometimes overlooked for several
reasons:
If the exhaust area is confined, (for
example, if the unit vents into a
crawlspace), then as the temperature
outside the unit rises, the WhisperKOOL
unit must expend more energy (and will
generate more heat) in order to maintain a
cool temperature inside the room.
Eventually, the unit cannot keep up and the
temperature inside the cellar climbs.
1.) If there is inadequate ventilation on
the rear side of the unit, this will
result in further heat buildup and will
To solve the problem, make sure that the
WhisperKOOL vents into a space of the
same size or larger where heat cannot
build up.
Door Seal
A high quality door with a proper seal is
another important aspect of a well-
designed cellar. If there is a gap between
the bottom of the door and the floor, the
cool air will sink and flow out beneath the
door. While the release of the cool air may
be subtle, it will require the
WhisperKOOLunit to continue to operate
without achieving the desired results. Use
good-quality weather-stripping and seals
echnology Thermostat
Precision digital
T
INE
W
Temperature
SET
SET
Air flows on both sides of the wall.
cause it to recirculate the hot air near
the ceiling on the exhaust side of the
unit, therefore limiting the ability to
cool the room.
echnology Thermostat
Precision digital
T
E
IN
e
ur
W
t
era
T
e
mp
SET
SET
2.) Even though the space may seem to be
adequate, the heat needs to be able to
dissipate away from the unit. A lack of
ventilation and air circulation will
cause the room to become extremely
warm.
3.) The WhisperKOOL unit is designed to
cool 30°F cooler than the ambient
temperature of the room it is
exhausting the hot air to (rear side of
unit). This means that in order to
maintain an optimum temperature of
55°F, the temperature on the exhaust
side of the WhisperKOOL unit cannot
be more than 85°F.
Cool air drops and exits beneath door.
-19-
Download from Www.Somanuals.com. All Manuals Search And Download.
around the cellar door to prevent cool air
leakage. For more details, see Preparing
the Wine Cellar, “Door” on page 6.
thermostat installed.
4.) Plug the WhisperKOOL unit back in.
The unit will begin running and
cooling immediately. Let the unit run
for 24 hours.
Unit Mounting
Mounting the unit in the cellar has a
significant impact on the unit’s ability to
cool the air in the room. A law of nature
states that warm air rises while cool air
falls. The unit must be mounted high in
the room in order to capture the warm air
and replace with cool air. If the unit is
mounted low in the cellar, it has a
tendency to circulate the cool air at the
5.) After 24 hours, use an accurate
thermometer (preferably a high-
quality digital thermometer) to
measure the temperature of air
coming out of the WhisperKOOL
unit’s front fans. If it is cooling the
room, then the problem may lie with
the thermostat.
If the WhisperKOOL unit cools the room
without the PDT installed, then the
thermostat should be replaced. The by-
pass plug will allow the WhisperKOOL
unit to continue to function, but it will not
be able to monitor or maintain the correct
temperature automatically without the
thermostat.
If you continue to run the WhisperKOOL
on the by-pass plug without the
thermostat, you will need to turn off the
WhisperKOOLunit periodically to keep it
from icing up. We recommend cycling the
unit on and off every eight hours if
possible or as needed.
For replacement of the PDT, please
contact Customer Service. See Warranty
Service on page 29.
Mount WhisperKOOL high in the room.
bottom of the cellar but has no ability to
draw the warm air from the higher space
in the cellar. This will result in an
inconsistent temperature range.
Thermostat
If the WhisperKOOL unit is not cooling
the room, it might be due to a faulty
thermostat. Use the following procedure
to test the thermostat (see pg. 25).
1.) Unplug the WhisperKOOLunit.
2.) The PDT thermostat is attached
to the front of the WhisperKOOL unit
with two screws, one at each end of the
thermostat. Remove the screws and
detach the PDT.
3.) Unplug the PDT from the main unit,
and plug in the by-pass plug. The by-
pass plug lets you run the
WhisperKOOL without having the
-20-
Download from Www.Somanuals.com. All Manuals Search And Download.
Condensation
Power Requirements
Water Leaking, Rear
When the WhisperKOOLstarts to operate,
it draws several times more power
(amps) during the start-up cycle than it
does during normal operation. Make sure
you have the WhisperKOOL on a
dedicated electrical line at a minimum of
20 amps. See the Product Information
Table on page 10 to find the correct
amperage requirement for your unit.
The WhisperKOOL product is designed to
dissipate excessive moisture by collecting
it in the compressor pan and using the
natural compressor heat along with a
heating element to remove condensation.
Operating the WhisperKOOL
in
excessively humid conditions can cause
the unit to accumulate more condensation
(water) then the unit can dissipate while
operating, resulting in leakage. In order
to resolve this issue, the unit is designed
with both a Condensate Evaporator
control switch and an external drain line
(see page 13). The Condensate
Evaporator switch will allow you to
operate the heating element continuously
whether the unit is operating or not. (See
Condensate Evaporator on page 13.)
Make sure that the power line for the
WhisperKOOL does not have any
additional equipment installed on that
circuit. An extra load on the line may be
drawing power away from the
WhisperKOOL unit. In some cases it may
not be readily apparent that an additional
appliance or electrical device has been
installed on the circuit breaker. In
addition, the unit may not be used on an
electrical line with a Ground Fault
Interrupter (GFI). The WhisperKOOL will
draw more amperage than the GFI will
allow.
Icing Up
In the unlikely event that your
WhisperKOOL unit is icing up in front,
unplug the unit for 24 to 36 hours and
allow the ice to melt away. Plug the unit
back in and test on the by-pass plug for
24 hours (refer to page 20 and 25).
Within the 24 hour period the unit should
not develop ice and should be generating
cold air. If the unit is functioning properly
when on by-pass, the icing may have been
a result of a faulty thermostat (see page
20). If while on by-pass, the unit
continues to form ice, first check that all
4 fans are working. Secondly, check to
see if the unit is blowing cold air. If the
air is cool to luke warm, but not cold, the
unit requires further service.
Repairing Units - Removing Rivets
Only a certified HVAC tech should work on
the units. We do not want owners opening
the units for their own safety.
1. Unplug the WhisperKOOL unit.
2. Remove the WhisperKOOL unit from the
wall mounting and set it on a sturdy work-
bench.
3. Drill out the rivets on the top panel that
hold the case together, using a 3/32 (size) drill
bit. This will destroy the rivets.
4. Remove the top off of unit, and carefully
remove the insulation (if any) from the top.
5. When replacing the panel, you can use
rivets or small metal 6-32 3/8” Phillips Pan
Head Screws. It is recommended to locate any
necessary parts at your local hardware store
prior to the service.
Please contact Customer Service for
assistance and guidelines. Before
contacting Customer Service, see pages
23-26.
-21-
Download from Www.Somanuals.com. All Manuals Search And Download.
Consumer Care Program
The Consumer Care Program is designed
to expedite the shipment of a replacement
unit to your location quickly in order to
get your cellar cooling again.
This program involves contacting our
Customer Service department to
purchase a refurbished unit in exchange
for your original unit. You will receive a
unit which has undergone our five star
refurbishment program. The unit is tested
in our controlled environment and is
ready for immediate use.
Upon receiving the unit, you will be
required to repackage your old unit and
ship it back to the factory within 30 days.
Complete details of our program including
pricing are available by contacting our
Customer Service department.
-22-
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING CHECKLIST
Please ꢂll out this checklist to help identify the issue or problem with the performance of the
cooling unit. If you still require technical assistance, fax a copy of this Troubleshooting Checklist
to Vinotheque Customer Service at 209.466.4606. Be sure to include accurate contact
information.
Customer Name: ________________________________________ Phone: ___________________
Email address: _____________________________________________________________________
Unit model: ______________________________________ Serial Number: A_________________
General Inspection
Unit Installation
1)
Is the unit installed in the correct direction, with front side of unit in wine
cellar and back side in exhaust room/space? Refer to page 12 of the
owner’s manual.
Yes
Yes
No
No
2)
Is the unit mounted within 18” from ceiling to allow
proper air circulation? Refer to page 6 of the owner’s manual.
Wine Cellar
3)
Is the cellar door sealed properly? To check, make sure cellar door is
Yes
Yes
No
No
closed and lights are turned oꢀ within cellar; light from outside should not
be visible through any of the four sides around the door.
4)
Are there any glass windows and/or glass doors in the cellar?
5)
6)
What is the R value of the walls? ___________
Are any of the cellar walls in the direct path of the sun?
What is the cellar room size? _________________
Yes
Yes
Yes
No
No
No
7)
8)
Are any of the walls on an exterior wall?
Is there foam attached to the ꢁange of the Whisperkool unit?
See page 8 of the owner’s manual.
General Ventilation
9)
Is there at least 3’ of unobstructed clearance for the fans and grills on the
Yes
Yes
No
No
unit? Obstructions to the air ꢁow greatly reduce the eꢀectiveness of the
unit’s ability to cool the cellar. Refer to page 7 of the owner’s manual.
Are there any decorative plates/covers on the unit? If so, remove them. They
obstruct air ꢁow to and from the vents. Refer to page 7 of the owner’s
manual.
10)
11)
12)
Is the unit on top of, in, or surrounded by shelving? Nearby ꢁat surfaces,
such as shelving, may obstruct air circulation and ventilation.
Are all four fans in the unit operating? (Two are in the front, and two are in
the back.)
Yes
Yes
No
No
Exhaust Room/Space Ventilation:
13) Into what kind of room/space is the unit exhausting?
To Outside
Crawl Space
Utility Space
14) Is the exhaust room/space as large as or larger than the cellar?
15) Is the exhaust room/space warm?
Yes
Yes
No
No
16) What is the temperature? __________
17) Is there any ventilation into and out of the exhaust room/space? Please
describe. Refer to page 7 of the owner’s manual.
Yes
No
No
18) Have the coils in the front and back of the Whisperkool unit been vacuumed?
Yes
-23-
Download from Www.Somanuals.com. All Manuals Search And Download.
Speciꢀc Performance Issues:
Unit is Not Cooling Suꢁciently or Not Cooling at All:
19) On a thermostat with digital readout, what is the set temperature? To
check, hold down the “SET” button on the thermostat to see the set
temperature. Refer to page 16 of the owner’s manual.
Set Temp:
Temp:
20) What is the actual temperature of the cellar?
*To check air temperature, use a digital thermostat which can be purchased
at any hardware store under kitchen supplies.
21) On a thermostat with digital readout, does the thermostat display two
horizontal dashes or the letters “PRB”? (This indicates a problem with the
thermostat.)
22) Is the probe inserted into a bottle of water? Refer to page 14 of the owner’s
manual.
Yes
Yes
No
No
Water is Leaking from the Unit:
All units come with a drain line for additional removal of excess condensate, as a back
up system to the Condensate Evaporator which is used to maintain proper humidity.
It is critical to install the drain line attachment for the unit to function eꢀectively,
preventing overꢁows and leaks from build up of condensate. See page 13.
Failure to install drain line will void warranty.
23) Is the unit level?
24) Is the drain line attached?
25) Is the unit leaking from the back?
Yes
Yes
Yes
No
No
No
This is generally due to an improper setting on the condensate evaporator.
In high humidity regions, the condensate evaporator should be set to “ON”
while other regions should be set to “AUTO”.
Refer to page 13 of the owner’s manual.
Unit is Icing Up:
26) Is the unit icing up? Allow the unit to thaw for 24-36 hours and ensure that
there is adequate air ꢁow to and from the unit before operating again.
Obstructed airꢁow is a possible reason why units ice up. Refer to page 21
of the owner’s manual.
Yes
No
Unit Short Cycles, Clicks Intermittently, Trips Breaker, or does not Run:
27) Is there power being supplied to the outlet? To check, test the outlet using
a small appliance (hairdryer).
28) Is the unit on a GFI (Ground Fault Interrupter)? The unit should not be run
on a GFI. Refer to page 10 of the owner’s manual.
29) Does the unit have a dedicated electrical line and 20 ampcircuit breaker?
To check, examine the breaker box to see if the cellar is on its own circuit.
Refer to page 21 of the owner’s manual.
Yes
Yes
Yes
No
No
No
30) Are there any large appliances plugged into the same room or in the same
area of the building of the cooling unit? Refer to page
21 of the owner’s manual.
Yes
No
-24-
Download from Www.Somanuals.com. All Manuals Search And Download.
TEMPERATURE DIFFERENTIAL TESTING
The purpose of this test is to evaluate whether or not your cooling unit is operating correctly by
measuring the temperatures of both the inside of the cellar and the exhaust side of the unit in
the adjoining room. The majority of problems found with cooling units result from inadequate
ventilation on the exhaust (back) side of the unit; therefore, taking these measurements is
critical in ensuring the optimal performance of the product while minimizing costs of operation.
The WhisperKOOL unit is designed to maintain relative humidity between 50-70%, which is
accomplished by cooling the cellar slowly. You should anticipate an approximate 10 - 15 degree
temperature differential between the inlet air temperature and the outlet air temperature on the
evaporator (front) side of the unit.
When testing the air temperature, please hold the thermometer in the appropriate location for
a full minute before recording temperatures so that the thermometer has stabilized. Do not use
PDT Probe! *
Please refer to the images at the end of the document as a guide to where to measure the
temperature of the inlet/outlet air:
*Note: to check air temperature, use a digital thermostat which can be purchased at any
hardware store under kitchen supplies.
First Temperature Test:
1. Stabilize the unit by turning it on and letting it run for five minutes before
performing the first temperature test.
2. Measure temperature of the inlet air going into the cooling unit on the evaporator
(front) side.
3. Measure temperature of the outlet air discharging out of the cooling unit on the
evaporator (front) side by holding the thermometer at the outer edge of the circular fan.
4. Record information and calculate temperature differential in table below for the
evaporator (front) side section under the first test.
5. On the back side of the unit, measure temperature of the inlet air going into the cooling
unit on the condenser (back) side.
6. On the back side of the unit, measure temperature of the outlet air discharging out of
the cooling unit on the condenser (back) side by holding the thermometer at the outer
edge of the circular fan.
7. Record information and calculate temperature differential in table below for the
condenser/back side section under the first test.
Second Temperature Test:
8. After the unit has run for 8 hours, perform the second temperature test.
9. Record information and calculate temperature differential in table below for the
condenser/back side section under the second test.
-25-
Download from Www.Somanuals.com. All Manuals Search And Download.
Third Temperature Test:
10. After the unit has run for 24hours, perform the third and last temperature test.
11. Record information and calculate temperature differential in table below.
Temperature Data from Testing
Temperature \ Test (time)
First (after 5 mins)
Second (after 8 hrs)
Third (after 24 hours)
Inlet Air
Outlet Air
Differential
(Inlet – Outlet = _; ideally 10°F-15°F)
Inlet Air (ideally <90°F)
Outlet Air (ideally <120°F)
Differential
(Inlet – Outlet = _; ideally around 30°F)
Temperature Testing Locations
Inlet Air – Evaporator (Front) Side
Outlet Air – Evaporator (Front) Side*
Inlet Air – Condenser (Back) Side•
Outlet Air – Condenser (Back) side*
*When measuring outlet air temperature on both sides of the unit (from the
circular fans), hold the thermostat at the outer edges of one of the circular fans.
-26-
Download from Www.Somanuals.com. All Manuals Search And Download.
Conclusions
After completing the temperature differential test, determine if the unit is not cooling at all or if
it is not cooling enough.
If the unit is not cooling at all, contact Vinothèque Customer Service at 800.343.9463. Be sure
to have the measurements and results from your Temperature Differential test available.
If the unit is cooling but not cooling fully (with a evaporator differential of 10°F-15°F and a
condenser differential of approximately 30°F), it indicates that there is too much heat on the back
side of the unit. In this case, you should:
• Check to make sure that there is at least 3’ of unobstructed space in front of the fans/vents
to allow adequate ventilation. Improper ventilation causes the majority of problems with
cooling units.
• On the condenser side, if the inlet air temperature is >90°F and/or the outlet air
temperature is >120°F, there is too much heat on the back side of the unit which is
preventing it from cooling fully. To remedy this, heat needs to be dissipated away from the
unit through an exhaust fan or other means of ventilation on the exhaust side. You can
contact Vinothèque Customer Service to request a ducting flange adapter at no charge to
assist in directing heat away from the unit (for warranty units only).
• You might consider installing a Vinothèque approved ventilation ducting system for your unit
which can be obtained through Vinothèque Customer Service.
·
• Contact Vinothèque Customer Service at 800.343.9463. Be sure to have the measurements
and results from your Temperature Differential test available.
-27-
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL ASSISTANCE
Vinothèque Customer Service is available Monday through
Friday from 8:00 a.m. to 4:00 p.m. Pacific Standard Time.
Please make sure that you have the following information
available before you call:
• The model and serial number of your WhisperKOOL
unit.
• Type of thermostat used with your WhisperKOOL.
• Location and installation details, such as ventilation,
construction and size of room.
• Photos of installation of unit from 10 to 15 feet away,
front and back.
• Completed
Troubleshooting
Checklist
and
Temperature Differential Testing form.
How To Contact Vinothèque Customer Service
Telephone
Fax
(209) 466-9463 (800) 343-9463
(209) 466-4606
Website
Address
Vinothèque Wine Cellars
1738 East Alpine Avenue
Stockton, CA 95205
-28-
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION TERMS AND CONDITIONS
WHISPERKOOL XLT/EXTREME COOLING SYSTEM
ATTENTION: PLEASE READ THESE TERMS OF USE CAREFULLY BEFORE INSTALLING YOUR
WhisperKOOL XLT/Extreme Cooling System. INSTALLING YOUR WhisperKOOL XLT/Extreme
Cooling System INDICATES THAT YOU ACCEPT AND AGREE TO EACH OF THE TERMS AND
CONDITIONS SET FORTH HEREIN ("TERMS OF USE"). IF YOU DO NOT ACCEPT THESE TERMS
OF USE, YOU RISK VOIDING YOUR WARRANTY AND ASSUMING ADDITIONAL REPAIR AND
REPLACEMENT COSTS.
1. Acceptance of Terms and Conditions Use and installation of a WhisperKOOL
XLT/Extreme Cooling System assumes that the consumer (“user”) fully accepts and agrees to
the Terms and Conditions set forth in this document. The Terms and Conditions also state that,
by signing and returning this document, you are certifying you have read, understood, and agreed
to our Terms and Conditions, as well as our User’s Manual. The User’s Manual is shipped with
each unit and, if another copy is needed, replacement copies can be downloaded from the
directly for a new copy. Vinothèque reserves the right, in its sole discretion, to change its Terms
and Conditions at any time, for any reason, without notice.
2. Product Installation
Subject to these Terms and Conditions, when the user purchases a WhisperKOOL XLT/Extreme
Cooling System, the user agrees to read and follow the required installation procedures set forth
by Vinothèque for proper use and installation of the Product.
(a) It is highly recommended that you obtain the assistance of a wine storage professional.
(b) Failing to address all of the variables associated with proper installation will cause the unit to
operate incorrectly and limit its ability to cool and the longevity of the unit itself.
(c) The warranty card must be returned to Vinothèque, the manufacturer, to ensure registration
guaranteeing the full warranty period is granted. Failure to register the product within thirty (30)
days of installation may result in a loss of warranty.
(d) The user is responsible for the full costs of installation and any additional parts required for the
proper and complete installation of the Product.
(e) The WhisperKOOL XLT cooling system cannot operate at its optimum capacity if airflow is
constricted by ducting or venting the exhaust side of the unit into a location with inadequate
ventilation.
3. Product Warranty Information
If a problem arises with your WhisperKOOL system during the warranty period, you must contact
Vinothèque Customer Service for warranty coverage and repairs. Removing the rivets from the
unit housing without authorization from the manufacturer will VOID the warranty. Please contact
a customer service representative for assistance before beginning work on a WhisperKOOL unit
that is still under the two (2) year manufacturer warranty.
For XLT/Extreme Cooling Systems returned to Vinothèque following warranty guidelines,
Vinothèque warrants this product against defects in material or workmanship as follows:
(a) LABOR: For a period of two (2) years from the date of purchase. If this Product is found to be
defective after undergoing customer service troubleshooting, Vinothèque will repair or replace the
product, at its option and discretion, at no charge to the customer. After the Warranty Period, the
customer is responsible for ALL labor and freight charges.
(b) PARTS: Vinothèque will supply, at no charge, new or rebuilt replacement parts in exchange for
defective parts for a period of two (2) years.
-29-
Download from Www.Somanuals.com. All Manuals Search And Download.
(c) FREIGHT: During the first two (2) years from the date of purchase, Vinothèque will cover
freight for the repair of units UNDER WARRANTY to customers within the continental United
States.
This warranty does not cover cosmetic damage caused during installation or damage due to acts
of God, accident, misuse, abuse, negligence, or modification to any part of the product. This
warranty does not cover damage due to improper operation or lack of proper maintenance,
connection to improper voltage supply, or attempted repair by anyone other than a technician
approved by Vinothèque to service the product. This warranty does not cover products sold “AS
IS” or “WITH ALL FAULTS.” This warranty is valid only in the continental United States.
Proof of purchase in the form of a bill of sale or receipted invoice, which is evidence that the
product is within the warranty period, must be presented to obtain warranty service. This
warranty is void if the factory-applied serial number has been altered or removed from the
product.
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY
OF THE CONSUMER. VINOTHÈQUE SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS
PRODUCT. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS
PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, or
allow limitations on how long an implied warranty lasts, so the above limitations or exclusions
may not apply to you.
This warranty gives you specific legal rights and you may have other rights which vary from state
to state.
4. Maintenance
It is the user’s responsibility to remove any accumulated dust, lint, or other debris from the front
and rear intake grilles. This will restrict the airflow and may affect the unit’s ability to function
properly. Periodically cleaning the unit’s vents will help assure maximum cooling efficiency. The
drain tube must also be checked and kept clean and free of debris and mold to maintain proper
performance.
Mold is a natural living organism in the environment. It exists in the air in the form of
microscopic spores that move in and out of buildings through doors, windows, vents, HVAC
systems and anywhere else that air enters. Once it is discovered, mold must be addressed quickly
and appropriately. Delayed or improper treatment of mold issues can result in costly and
recurring repairs. If you suspect you have a mold problem, it is always best to hire a qualified
and experienced mold remediation specialist.
5. User Costs and Responsibility
The following items are not covered under warranty and are the sole responsibility of the user.
(a) The user is responsible for ALL initial installation costs, including, but not limited to, labor
costs and the cost of any additional parts necessary to complete the installation.
(b) The user is responsible for the costs incurred for installation and removal of the product or
any part thereof unless it has been defined as a warranty repair PRIOR to the work being
performed.
(c) Purchasers (users) are reminded that they should satisfy themselves that the product they are
purchasing is suitable for their needs and requirements and no responsibility will be placed with
Vinothèque for their decisions.
(d) It is the user’s responsibility to secure safe haven/storage for ANY AND ALL items that are
being kept and stored in the user’s wine cellar. Vinothèque takes no responsibility for the safety
and preservation of the aforementioned items in the event that the environment becomes
unsuitable for proper storage
-30-
Download from Www.Somanuals.com. All Manuals Search And Download.
6. State Sales Tax
We collect California Sales Tax only for orders made and shipped within California. We do not
collect sales tax for orders shipped to other states. However, you may be liable for sales tax to
your state for the merchandise you receive. You may want to check with your state’s tax authority
for “use tax” regulations.
7. Customer Service
Vinothèque’s customer service department is available Monday through Friday, from 8:00AM to
4:00PM PT by calling 1-800-343-9463.
8. Trouble Shooting
The customer service department is available to answer any questions or inquiries regarding our
product as well as to assist in basic and primary troubleshooting for any problems with our
product.
9. General Provisions
(a) Construction and severability. Every provision of these Terms and Conditions will be
construed, to the extent possible, so as to be valid and enforceable. If any provision of these
Terms and Conditions so construed is held by a court of competent jurisdiction to be invalid,
illegal or otherwise unenforceable, such provision will, to the extent so held, be deemed severed
from these Terms and Conditions, and all other provisions will remain in full force and effect.
(b) Governing Law/Choice of Forum. The laws of the State of California (without regard for
conflicts of law) shall govern the construction and enforcement of these Terms and Conditions,
except that the Terms and Conditions shall be interpreted as though drafted jointly by Vinotheque
and the Purchaser. Any dispute will be resolved in a state or federal court situated in the County
of Santa Clara, State of California, and the
Purchaser hereby irrevocably submits to the personal jurisdiction of such courts for that
purpose.
(c) Entire Agreement/No Waiver. These Terms and Conditions and the Limited Warranty
incorporated herein by reference set forth the entire agreement between the parties and
supersede all prior agreements or understandings, both written and oral, between the parties
regarding the subject matter of this the Terms and Conditions and the Limited Warranty. The
parties may modify these Terms and Conditions or the Limited Warranty only in a writing signed
by each. No waiver by Vinothèque of any breach or default hereunder will be deemed to be a
waiver of any preceding or subsequent breach or default.
(d) Correction of Errors and Inaccuracies. These Terms and Conditions may contain
typographical errors or other errors or inaccuracies. Vinothèque reserves the right to correct any
errors, inaccuracies or omissions, and to change or update these Terms and Conditions, at any
time, without prior notice.
10. Questions or Additional Information
If you have any questions regarding these Terms and Conditions or wish to obtain additional
information, contact us via phone at 1-800-343-9463 or please send a letter via U.S. Mail to:
Vinothèque Wine Cellars
1738 E. Alpine Ave
Stockton, CA 95205
-31-
Download from Www.Somanuals.com. All Manuals Search And Download.
-32-
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
1738 East Alpine Avenue
Stockton, California 95205
Download from Www.Somanuals.com. All Manuals Search And Download.
|