Whirlpool Clothes Dryer WGT3300S User Manual

®
27" (69 cm) Gas Washer/Dryer  
PRODUCT MODEL NUMBER  
PRODUCT DIMENSIONS  
WGT3300S  
Gas supply: This washer/dryer is equipped for use with Natural  
gas. It is design-certified by CSA International for LP (propane or  
butane) gases with appropriate conversion.  
Gas supply line must include 1/8" NPT minimum plugged tapping  
accessible for test gauge connection, immediately upstream of the gas  
supply connection to the dryer. 1/2" IPS pipe is recommended. 3/8"  
approved aluminum or copper tubing is acceptable for lengths under  
20 ft (6.1 m) if local codes and gas supplier permit. If you are using  
Natural gas, do not use copper tubing. Lengths over 20 ft (6.1 m)  
should use larger tubing and a different size adapter fitting. Gas  
supply line coupling must be 34" (864 mm) to 37" (940 mm) from the  
floor.  
715  
"
8
23 3  
"
(181.9 cm)  
4
(60.3 cm)  
* Most installations require a  
321  
(81.9 cm)  
"
minimum 5" (12.7 cm) clearance  
behind the dryer for the exhaust  
vent with elbow.  
4
An individual manual shutoff valve must be installed within six (6) feet  
(1.8 m) of the washer/dryer in accordance with the National Fuel Gas  
Code, ANSI Z223.1.  
NOTE: Pipe-joint compounds that resist the action of LP gas must be  
used. Do not use TEFLON®† tape.  
*32"  
(81.3 cm)  
27"  
(68.6 cm)  
Electrical: A 120-volt, 60-Hz, AC-only, 15- or 20-amp, fused  
electrical supply is required. A time-delay fuse or circuit breaker is  
recommended. It is also recommended that a separate circuit serving  
only this appliance be provided.  
RECESSED AREA AND CLOSET INSTALLATION  
Exhaust venting: Use a heavy metal vent. Do not use plastic or  
metal foil vent. 4" (10.2 cm) heavy metal exhaust vent and clamps  
must be used. DURASAFE™ venting products are recommended.  
Exhaust outlet hood must be at least 12" (30.5 cm) from the ground or  
any object that may be in the path of the exhaust.  
For closet installation, with a door, minimum ventilation openings in the top and  
bottom of the door are required. Louvered doors with equivalent ventilation openings  
are acceptable.  
6"  
3"  
(15.2 cm)  
(7.6 cm)  
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.  
48 in.2  
(310 cm2)  
EXHAUST VENTING  
24 in.2  
3"  
(155 cm2)  
Select the route that will provide the straightest and most direct path  
outdoors. Plan the installation to use the fewest number of elbows  
and turns. Use the fewest 90° turns possible.  
(7.6 cm)  
1"  
27"  
1"  
1"*  
5"**  
(12.7 cm)  
32"  
(2.5 cm) (68.6 cm) (2.5 cm)  
(2.5 cm)  
(81.3 cm)  
Do not use vent runs longer than specified in vent length chart.  
Determine the number of elbows  
A
B
C
A. Recessed area  
B. Side view - closet or confined area  
C. Closet door with vents  
2
you will need.  
4"  
(10.2 cm)  
1
*Required spacing  
**Rear clearance may be 1" (2.5 cm) when house exhaust system  
is lined up directly with dryer exhaust.  
4"  
(10.2 cm)  
(6.4 cm)  
4"  
(10.2 cm)  
Angled hood style  
DRAIN SYSTEM  
Standpipe drain system - wall or floor  
1. Louvered hood style  
2. Box hood style  
The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The  
minimum carry-away capacity can be no less than 17 gal. (64 L) per minute. A 2"  
(5 cm) diameter to 1" (2.5 cm) diameter standpipe adapter kit is available.  
The top of the standpipe must be at least 39" (99 cm) high and no higher than 96"  
(2.4 m) from the bottom of the washer.  
Vent Length Chart  
No. of  
90° turns  
or elbows  
Type of Vent  
Box or  
Angled  
hoods  
Louvered  
hoods  
Laundry tub drain system  
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub  
must be at least 34" (86.4 cm) above the floor and no higher than 96" (2.4 m) from the  
bottom of the washer.  
Floor drain system  
The floor drain system requires a siphon break that may be purchased separately.  
0
1
2
Rigid metal  
Rigid metal  
Rigid metal  
37 ft (11.3 m)  
32 ft (9.7 m)  
24 ft (7.3 m)  
35 ft (10.7 m)  
27 ft (8.2 m)  
19 ft (5.8 m)  
The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer.  
Additional hoses might be needed.  
NOTE: Side exhaust adds a 90° turn inside the washer/dryer. To  
determine maximum exhaust length, add one 90° turn to the  
chart.  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10222381  
10-30-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weider Home Gym 831153930f User Manual
Weider Home Gym WESY49310 User Manual
Westinghouse Flat Panel Television EW40T2XW User Manual
Whirlpool Air Conditioner ACE082XR0 User Manual
Whirlpool Freezer EH12OC EH15OC User Manual
Whirlpool Oven GBS307PRB01 User Manual
Whirlpool Washer Dryer W10222384A User Manual
Xerox Computer Monitor XA7 User Manual
Xpelair Fan PX12 User Manual
Zenoah Blower BM40S User Manual