Vermont Casting Indoor Fireplace RHE25 User Manual

Natural Vent Insert  
Models: RHE25  
RHE32  
RHE42  
Installation Instructions & Homeowner's Manual  
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR  
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,PERSONAL INJURY OR LOSS OF LIFE.  
FOR YOUR SAFETY  
FOR YOUR SAFETY  
WHAT TO DO IF YOU SMELL GAS:  
Do not try to light any appliance.  
DO NOT STORE  
OR USE GASOLINE OR OTHER  
FLAMMABLE VAPOURS AND LIQUIDS  
IN THE VICINITY OF THIS OR ANY  
OTHER APPLIANCE.  
Do not touch any electric switch  
Do not use any phone in your building.  
Immediately call your gas supplier from your  
neighbours phone. Follow the gas suppliers  
instructions.  
Installation and service must be performed by  
a qualified installer, service agency or your gas  
supplier.  
If you cannot reach your gas supplier call the  
fire department.  
Vermont Castings, Majestic Products  
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777  
CERTIFIED  
I
INSTALLER: DO NOT DISCARD THIS MANUAL - Leave For Homeowner  
10000836 8/03 Rev.3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Installation Instructions  
This gas appliance should be installed by a qualified installer  
IMPORTANT:  
in accordance with local building codes and with current CSA-  
B149.1 Installation codes for Gas Burning Appliances and  
Equipment.  
PLEASE REVIEW THE FOLLOWING CAREFULLY  
Remove any plastic from trim parts before turning the  
fireplace ON.  
For U.S.A Installations follow local codes and/or the current  
National Fuel Gas Code. ANSI Z223.1.  
It is normal for fireplaces fabricated of steel to give  
off some expansion and/or contraction noises during  
the start up or cool down cycle. Similar noises are  
found with your furnace heat exchanger or car  
engine.  
FOR SAFE INSTALLATION AND OPERATION OF YOUR  
MAJESTIC GAS FIREPLACE INSERT PLEASE NOTE THE  
FOLLOWING:  
1. This appliance gives off high temperatures and should be  
located out of high traffic areas and away from furniture  
and draperies.  
2. Children and adults should be alerted to the hazards of the  
high surface temperatures of this appliance and should  
stay away to avoid burns or ignition of clothing.  
3. Children should be carefully supervised when they are in  
the same room as your appliance.  
4. Under no circumstances should this appliance be modified.  
Parts removed for servicing should be replaced prior to  
operating this appliance again.  
5. Installation and any repairs to this appliance should be  
carried out by a qualified service person. A professional  
service person should be contacted to inspect this appli-  
ance annually. Make it a practice to have all of your gas  
appliances checked annually. More frequent cleaning may  
be required due to excess lint and dust from carpeting,  
bedding material, etc.  
It is not unusual for your Majestic gas fireplace to  
give off some odor the first time it is burned. This is  
due to the curing of the paint and any undetected oil  
from the manufacturing process.  
Please ensure that your room is well ventilated -  
open all windows.  
It is recommended that you burn your Majestic  
fireplace for a least six (6) hours the first time you  
use it. If optional fan kit has been installed, place fan  
in the "OFF" position during this time.  
Locating Your Gas Fireplace Insert with  
Zero Clearance Kit  
6. Control compartments, burners and air passages in this  
appliance should be kept clean and free of dust and lint.  
Make sure that the gas valve and pilot light are turned off  
before you attempt to clean this unit.  
7. The venting system (chimney) of this appliance should be  
checked at least once a year and if needed your venting  
system should be cleaned.  
X
A
B
E
C
D
X
8. Keep the area around your appliance clear of combustible  
materials, gasoline and other flammable vapor and liquids.  
This appliance should not be used as a drying rack for  
clothing, nor should Christmas stockings or decorations be  
hung in the area of it.  
9. Under no circumstances should any solid fuels (wood, coal,  
paper or cardboard etc.) be used in this appliance.  
10.The flow of combustion and ventilation air must not be  
obstructed in any way.  
X
F
FP1249  
Fig 1. Locating unit with zero clearance kit.  
A) Flat on wall  
C) Island  
B) Cross corner  
D) *Room divider  
E) *Flat on wall corner  
F) Chase installation  
11.These appliances are certified for installation in a solid fuel  
burning fireplace unless using the model HEZC Zero  
Clearance kit. When the Zero Clearance kit is used, and  
the appliance is installed directly on carpeting, vinyl tile or  
any combustible material other than wood, the appliance  
must be installed on a metal or wood panel extending the  
full width and depth of the appliance.  
NOTE: (Fig. 1)  
* When you install your Majestic fireplace in (D) Room divider  
or (E) Flat on wall corner positions, a minimum of 6" (X)  
(153mm) clearance must be maintained from the perpendicu-  
lar wall and the outer edge of the trim.  
Insert Applications  
12.This appliance requires adequate ventilation and  
combustion air to operate properly.  
Before installing the gas fireplace insert, consideration  
must be given to the functioning needs of the fireplace.  
The size of the fireplace cavity, the design of the chimney  
for effective venting should be determined. The  
availability of the gas supply as well as electricity for the  
insert fan must be confirmed.  
Proposition 65 Warning: Fuels used in gas,  
woodburning or oil fired appliances, and the products  
of combustion of such fuels, contain chemicals known  
to the State of California to cause cancer, birth defects  
and other reproductive harm.  
California Health & Safety Code Sec. 25249.6  
10000836  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Fireplace Dimensions  
F
B
D
E
A
G
H
Maintain 1"  
(25mm) Clearance  
to B-Vent  
Zero Clearance Kit  
C
Minimum Fireplace  
Insert Opening  
M
P
N
L
O
U
S
K
Q
V
T
1"  
(25mm)  
Air Inlet Channel  
R
Gas Inlet Knock-out  
1 = SS or SSD Trim  
Q - Fireplace Opening Height T - Firebox Width at Insert Depth(s)  
2 = SL or SLD Trim  
3 = SXL Trim  
R - Fireplace Opening Width  
S - Depth of Insert  
U - Firebox Depth at Insert Back Height (V)  
V - Insert Back Height  
4 = BSL Trim  
5 = BXL Trim  
RHE25  
26³⁄₄" (680mm)  
RHE32  
RHE42  
(781mm)  
A-1  
B-1  
A-2  
B-2  
A-3  
B-3  
A-4  
B-4  
A-5  
26³⁄₈"  
38³⁄₈"  
29"  
(676mm)  
(975mm)  
(737mm)  
30³⁄₄"  
T
R
I
38¹⁄₂"  
(978mm)  
43¹⁄₈"  
(1095mm)  
29¹⁄₄"  
(743mm)  
33³⁄₈"  
(848mm)  
43¹⁄₂"  
(1105mm)  
41¹⁵⁄₁₆" (1065mm)  
48¹⁄₄"  
(1225mm)  
M
-
-
-
-
-
-
-
-
-
-
33"  
44"  
(838mm)  
(1118mm)  
(712mm)  
(1041mm)  
(775mm)  
-
-
-
-
-
-
-
-
-
-
28"  
40⁷⁄₈"  
30¹⁄₂"  
B-5  
C
-
-
46"  
28³⁄₄"  
(1171mm)  
(730mm)  
-
-
25¹⁄₄"  
(641mm)  
31"  
(787mm)  
F
I
D
E
F
17"  
13³⁄₄"  
15"  
(432mm)  
(349mm)  
(381mm)  
(489mm)  
(445mm)  
(889mm)  
(676mm)  
(216mm)  
(952mm)  
(486mm)  
17¹⁄₄"  
15⁵⁄₈"  
17¹⁄₈"  
20¹⁄₂"  
20"  
(438mm)  
(397mm)  
(435mm)  
(521mm)  
(508mm)  
(889mm)  
(676mm)  
(216mm)  
(952mm)  
(486mm)  
20¹⁄₈"  
17³⁄₄"  
21"  
(511mm)  
(451mm)  
(533m)  
R
E
P
L
A
C
E
G
H
K
L
19¹⁄₄"  
17¹⁄₂"  
35"  
23¹⁄₄"  
22³⁄₄"  
39¹⁄₄"  
31¹⁄₈"  
8¹⁄₂"  
(590mm)  
(578mm)  
(1000mm)  
(790mm)  
(216mm)  
(954mm)  
(553mm)  
35"  
26⁵⁄₈"  
8¹⁄₂"  
26⁵⁄₈"  
8¹⁄₂"  
M
N
O
37¹⁄₂"  
19¹⁄₈"  
37¹⁄₂"  
19¹⁄₈"  
37¹⁄₂"  
21³⁄₄"  
P
Q
27¹⁄₄"  
17³⁄₄"  
(692mm)  
(451mm)  
27¹⁄₄"  
21"  
(692mm)  
(533mm)  
25³⁄₄"  
23¹⁄₄"  
(654mm)  
(591mm)  
M
I
N
I
M
U
M
O
P
E
N
I
N
G
R
S
T
25"  
13³⁄₄"  
17¹⁄₂"  
14"  
(635mm)  
(349mm)  
(445mm)  
(356mm)  
(451mm)  
28"  
16"  
(711mm)  
(407mm)  
(451mm)  
(419mm)  
(514mm)  
29"  
18"  
737mm)  
(457mm)  
(524mm)  
(533mm)  
(584mm)  
17³⁄₄"  
16¹⁄₂"  
20¹⁄₄"  
20⁵⁄₈"  
21"  
U
V
17³⁄₄"  
23"  
4
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
The use of wallpaper adjacent to this  
fireplace is not recommended, as the  
high heat given off by this fireplace may  
adversely effect the binders in the adhe-  
sive used to apply the wallpaper.  
Mantels  
When the insert is being installed into a woodburning  
fireplace the minimum the mantel can be above the  
fireplace is governed by local building codes applicable  
to woodburning fireplaces. Consult local authorities  
having jurisdiction for these clearances.  
37¹⁄₄" (946mm)  
For applications requiring the use of a Zero Clearance  
Kit, the minimum a mantel can protrude above the  
fireplace is 24" (610mm) from the top of the upper  
louvres. The maximum mantel depth is 8" (200mm).  
(Fig. 2)  
35"  
The underside of the mantel will get quite  
warm. Use only finishes which are heat  
resistant and do not discolour.  
(889mm)  
24" Min.  
(610mm)  
19¹⁄₈" (486mm)  
(RHE25/32)  
21³⁄₄" (553mm)  
(RHE42)  
Air Inlet Channel  
27¹⁄₄" (692mm) (RHE25/32)  
25³⁄₄" (654mm) (RHE42)  
Dry  
Wall  
Finish Wall  
Decorative Trim Kit  
FP1325  
FP1351a  
Fig. 2 Minimum mantel height above fireplace.  
Fig. 3 RHE insert framing dimensions.  
Framing & Finishing  
Combustion Air  
For Zero Clearance Kit applications it is important to  
determine the finished facing material before beginning  
to frame. This will allow for the thickness of the  
finishing material between the frame and the fireplace  
trim.  
It is very important that an adequate air supply is  
available when the unit is being operated. Since most  
homes of today are tightly sealed and insulated,  
additional make-up air is usually necessary.  
This fireplace has been designed to operate by  
drawing air in from the front and outer perimeters of  
the fireplace. The air provides combustion air ensuring  
a clean burning flame, dilution air for proper venting, as  
well as, the air which the fan circulates over the  
firebox/heat exchanger system.  
Similarily, consideration must be given to the 1"  
(25mm) depth of the air inlet channel sitting on the  
fireplace base. Finishing material for the hearth should  
be flush with the top of the air inlet channel.  
If the fireplace is installed at floor level a non-  
combustible hearth must extend a minimum 12"  
(305mm) in front of the fireplace.  
Insulating around the fireplace will result in overheating  
and possible malfunctioning of the circulating fan.  
If the fireplace is recessed into the wall and at least 12"  
(305mm) above floor level, no hearth is required.  
A (3" for RHE25, 4" for RHE32 and RHE42) diameter  
Class "B" vent must be used when installing the  
fireplace insert along with the Zero Clearance Kit. The  
vent system must be a minimum height of 12' (3.7m).  
10000836  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Zero Clearance Applications  
The installation of your Majestic Fireplace  
must conform with local codes, or in the  
absence of local codes, with National Fuel Gas  
Code, ANSI Z223.1 latest edition, or CSA-  
B149.1 Installation Code. (EXCEPTION: Do  
not derate this appliance for elevations up to  
4,500 ft (1,370m). Maintain the manifold  
pressure at 3.5" w.c. for Natural Gas and 10.0"  
w.c. for LP gas.)  
An alternate air supply is recommended  
with this component.  
For installations other than in existing woodburning  
fireplaces such as new construction or renovation  
projects, a Zero Clearance Kit must be used. The kit  
enables these inserts to be installed in combustible  
environments. It is recommended that an Air Kit  
(AKZC) be installed whenever using a Zero Clearance  
Kit. Consideration must be given to the dimensions of  
the Zero Clearance Kit and the requirements of the Air  
Kit when planning the installation.  
High Elevations  
Input ratings are shown in BTU per hour and are  
certified without deration for elevations up to  
4,500 feet (1,370m) above sea level.  
For elevations above 4,500 feet (1,370m) in USA,  
installations must be in accordance with the  
current ANSI Z223.1 and/or local codes having  
jurisdiction.  
Gas Specifications  
Max. Min.  
Input Input  
Model  
Fuel  
Gas Control  
Millivolt HI/LO  
Millivolt HI/LO  
Manual HI/LO  
Manual HI/LO  
Millivolt HI/LO  
Millivolt HI/LO  
Btu/h Btu/h  
22,000 15,400  
22,000 16,500  
22,000 15,400  
22,000 16,500  
30,000 21,000  
30,000 22,500  
In Canada, please consult provincial and/or local  
authorities having jurisdiction for installations at  
elevations above 4,500 feet (1,370m).  
RHE25RN  
Natural Gas  
RHE25RP Propane Gas  
RHE25MN Natural Gas  
RHE25MP Propane Gas  
RHE3RN Natural Gas  
RHE32RP Propane Gas  
Preparation  
RHE32TN  
RHE32TP  
RHE42RN  
Natural Gas Thermostat HI/LO 30,000 21,000  
Propane Gas Thermostat HI/LO 30,000 22,500  
Before beginning, remove the glass frame from the  
fireplace. Also check to make sure there is no hidden  
damage to the fireplace. Take a minute and plan out  
the gas, vent and electrical supply. Refer to Glass  
Frame Removal section.  
Natural Gas  
Millivolt HI/LO  
Millivolt HI/LO  
40,000 28,000  
37,000 27,750  
RHE42RP Propane Gas  
RHE42TN  
RHE42TP  
Natural Gas Thermostat HI/LO 40,000 28,000  
Propane Gas Thermostat HI/LO 37,000 27,750  
Gas Line Installation  
Gas Inlet & Manifold Pressures  
When purging the gas line, the front  
glass must be removed.  
Natural  
LP  
11.0" W.C.  
Minimum Inlet Pressure  
Maximum Inlet Pressure  
Manifold Pressure  
5.5" W.C.  
The gas pipeline can be brought into the fireplace base  
from the right side. It is most convenient to install it  
from the right side into the gas fittings provided.  
14.0" W.C. 14.0" W.C.  
3.5" W.C. 10.0" W.C.  
Do not use this appliance if any part of it  
has been under water. Immediately call a  
qualified service technician to inspect the  
unit and replace any part of the control  
which has been under water.  
When using copper or flex connector use only  
approved fittings. Always provide a union when using  
black iron pipe so that gas line can be easily  
disconnected for burner or fan servicing. Refer to gas  
specifications for pressure details and ratings.  
These gas inserts are approved for installation in  
solid fuel burning masonry or zero clearance  
fireplaces.  
The gas line connection can be made of either properly  
tinned 3/8" copper pipe, 3/8" rigid pipe or an approved  
flex connector.  
The gas control inlet is 3/8" N.P.T. therefore the 1/2"  
rigid gas line must be reduced to 3/8" N.P.T. Typical  
installation layout for rigid pipe is shown following. (Fig.  
4)  
RHE25 / RHE32 / RHE42  
Certified To  
ANSI Z 21.88-2002 / CSA 2.33-2002  
Vented Gas Fireplace Heaters  
6
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Installation of Remote Switch  
for RN/RP Gas Valves  
1/2" Gas Supply  
1/2" x 3/8" Reducer  
3/8" x 3/8" Shut Off  
Valve  
1. Thread wire through gas inlet opening on the right  
side of fireplace. Do not cut wire or insulation on  
metal edges.  
3/8" Union  
2. Slide switch assembly from the back, between  
subframe and trim, then fasten the screw. (Fig. 6)  
3. For left side installation reverse switch position in  
bracket and repeat Step 2. (Fig. 7)  
3/8" Nipple  
FP1278  
4. Connect wiring to gas valve (Fig. 8a & b) and switch.  
Fig. 4 Typical gas supply installation.  
During any pressure testing of the gas line system,  
when the test pressures are to exceed 1/2 psi (3.5 kpa)  
the fireplace and its gas valve must not be connected  
to that system.  
Right Side Installation  
Left Side Installation  
Trim Top  
Trim Left  
Side  
Trim Right  
Side  
At test pressures equal to or less than 1/2 psi, the gas  
valve of the fireplace may be connected to the gas line,  
but must be in the closed position.  
ON/OFF Switch  
Assembly  
Wiring from  
Millivolt Gas  
Valve  
Some municipalities have additional local codes, it is  
always best to consult the local authority and the CSA-  
B149.1 installation code in Canada.  
Trim  
Screw  
Trim  
Screw  
FOR U.S.A Installations consult the current National  
Fuel Gas Code, ANSI Z223.1  
ON/OFF Switch Assembly  
FP1253  
Fig. 6 Slide switch assembly between subframe and trim.  
Always check for gas leaks with a mild soap  
and water solution. Do not use an open  
flame for leak testing.  
Bracket Switch  
Manifold Gas  
Outlet  
Brass  
Brass Plug  
Thermostat  
Bulb  
Plug  
Pressure  
Regulator  
Gas Inlet  
Thermocouple Inlet  
ON/OFF  
Switch  
Pilot Tube Entry  
Pilot  
Control Knob  
FP1254  
Adjustment  
Screw  
Control Knob  
Fig. 7 For left side installation, reverse switch position in  
bracket.  
i t  
Valve  
Minimum Rate Screw  
(Nonadjustable)  
Thermopile  
HV118  
Fig. 5 On fireplaces equipped with the Eurosit 630 gas  
valves, there are brass plugs in two of the holes. These  
plugs are not to be removed. The gas inlet hole has a plastic  
cap in it. Remove the plastic cap and connect your gas  
supply line at this point.  
The MN/MP valve control used on the  
RHE25 does not include the thermostat  
bullb as shown in Figure 5.  
FP382a  
Fig. 8a ON/OFF switch or millivolt thermostat.  
10000836  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Venting and Installation  
Installer must attach red warning plate  
with screws supplied with the gas fire-  
place insert to the inside of the firebox of  
the fireplace into which the gas fireplace  
insert is installed.  
WARNING  
This fireplace has been converted for use with  
gas only and cannot be used for burning wood  
or solid fuels unless all original parts have been  
replaced and the fireplace has been re-approved  
by the authority having jurisdiction.  
FP1218a  
Fig. 8b ON/OFF switch wiring.  
If a remote wall switch is required for this  
fireplace installation, do not wire wall  
switch to 120V power supply.  
Cutting any sheet metal parts of the  
fireplace, in which the gas fireplace insert  
is to be installed, is prohibited.  
Venting Instructions  
If the factory-built fireplace has no gas  
access hole(s) provided, an access hole  
of 1¹⁄₂" (37.5mm) or less may be drilled  
through the lower sides or bottom of the  
firebox in a proper workmanship like  
manner. This access hole must be  
plugged with a noncombustible insulation  
after the gas supply line has been  
installed.  
Canadian Installations:  
The venting system must be installed in accordance  
with the current CSA-B149.1 installation code, and the  
authority having jurisdiction.  
U.S.A. Installations:  
The venting system must be installed in accordance  
with the current National Fuel Gas Code, ANSI Z223.1.  
Minimum clearances to combustible materials is 1"  
(25mm) for B Vent (use of single wall vent is not  
allowed).  
Ensure there are no obstructions to side  
air passages of decorative trim once  
installed on insert.  
As with any natural draft appliances, the vent cap must  
always extend a minimum of 2' (610mm) above any  
structure within a 10' (3m) horizontal plane. (Fig. 9)  
WARNING  
Some factory built fireplaces have air passages  
on face of fireplace for zero clearance capabili-  
ties. All trim kits are designed so as to allow  
airflow to these passages. Under no circum-  
stances should these passages be blocked.  
0 To 10’  
2’ Min.  
0 To 10’  
(3m)  
3’  
Min.  
2’  
1. The Majestic gas inserts are designed for recessed  
installations into solid fuel Masonry or Factory Built  
Noncombustible fireplaces that have been installed  
in accordance with the National, Provincial, State  
and local building codes.  
3’  
(610mm)  
Min.  
(914mm)  
Min.  
Reference  
Point  
AC246a  
2. Measure for minimum fireplace opening requirement  
on Page 4 of this installation manual. (If firebrick  
[refractory] is removed from a factory built  
fireplace in order to gain minimum gas fireplace  
insert opening requirements, a minimum of 1/4"  
(6.4mm) air space is required between the gas  
insert fireplace's outer casing and the inner wall  
of the factory built fireplace).  
Fig. 9 Example of the 2', 3', 10' rule.  
A minimum 12' (3.7m) vent height is  
required to effectively vent this fireplace.  
3. To assure top performance, safety and efficiency, all  
inserts must be installed with an approved 4"  
diameter flue liner, with exception of RHE25, which  
should be installed with an approved 3" liner,as per  
CSA-B.149 or National Fuel Code ANSI Z223.  
8
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
4. Flue damper must be fully blocked in the open  
Chimney Liner  
Damper  
Damper  
position or removed for installation.  
Chimney  
Liner  
5. The chimney must be clean and in good working  
order and constructed of noncombustible materials.  
Flue  
Collar Plate  
Clamp  
Screw  
Clamp  
6. Make sure that all chimney cleanouts fit properly so  
air cannot leak into the chimney.  
7. Glass door, screen kits and log grate may be  
removed for installation of insert into factory built  
fireplace.  
8. Install the insert without the trim frame and make all  
gas, venting and electrical connections.  
FP1354  
Fig. 10 Remove flue collar plate and attach to flue collar.  
9. Install decorative trim frame. Please refer to Frame  
Assembly and Mounting instructions on this manual.  
Test Chimney Draw  
A "Chimney Draw" test must be made before the  
installation is complete.  
Common Flue Installations  
In some areas it is possible to vent more than one gas  
fireplace into the same flue. You must ensure the flue  
being shared has the proper capacity to handle both  
fireplaces. Check installation codes for venting capacity  
information.  
1. Close all doors and windows in the home and start  
exhaust fans in the kitchen and bathroom.  
2. Light unit and operate for 5 minutes.  
3. Hold an ignited match or cigarette in front of the  
unit. Refer to Figure 11 for the location of the draft  
hood opening.  
4. Check to make sure smoke from the match or  
cigarette is drawn into the fireplace. If it is not, turn  
the unit off and check for causes creating the lack of  
adequate draft.  
As always it is best to check with the authority having  
jurisdiction prior to commencement of the installation.  
Liner Installation  
Insert liner from top of chimney through the damper  
opening and attach to 3" flue collar (for RHE25); 4" flue  
collar (for RHE32 & RHE42). For best results use  
three (3) sheet metal screws and a hose clamp.  
Test for Draft at This Location  
For natural draft inserts packing fibreglass insulation  
around the liner in the damper area will isolate the  
fireplace cavity from the chimney and prevent drafts  
and noises during operation.  
In case the fireplace opening is only minimum height  
(17¹⁄₂" for RHE25) (20" for RHE32) (22³⁄₄" for RHE42)  
and access from the front is not possible, remove the  
flue collar plate - unscrew and slide out from the back  
of the unit. Now attach the liner to the flue collar, lift up  
and simply slide flue collar plate back onto the unit top.  
It is important the plate is completely inserted and the  
front screw is fastened again in order to line up the flue  
outlet and the liner properly. (Fig. 10)  
FP1371  
Fig. 11 Hold an ignited match in front of fireplace.  
Vent Safety System  
These inserts are equipped with a vent safety shut  
down switch. This switch is factory installed, wired and  
tested. Check and make sure the switch and wires are  
in the proper position. The safety switch is heat acti-  
vated and wired in series with the pilot system. (Fig. 12)  
If fireplace lintel is wider than 8"  
(205mm), the height of the fireplace  
opening must be 25" (635mm) to allow  
for a 90° offset elbow to be installed.  
Bracket  
Draft Relief Opening  
This insert is equipped with a draft-relief opening which  
receives its dilution air supply through the opening  
behind the louvres. These openings must not be  
obstructed or altered in any way. (Fig. 11)  
Vent Safety  
Switch  
FP1372  
Fig. 12 Vent safety switch.  
10000836  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Operation of this fireplace when not  
connected to a properly installed and  
maintained venting system or tampering  
with the vent safety shutoff system can  
Stud  
result in carbon monoxide (CO)  
poisoning and possibly death.  
Thermal Sensor is  
attached to burner  
base  
Fan is installed  
at the back of  
the air intake  
box  
Fan Kit  
Stud  
Valve  
115 Volt, 60 Hz. 56W  
Fan Speed Control/Junction Box  
The fan kit includes the following: fan, temperature  
sensor, speed control and a 6 ft. cord. The following  
explains how to start and set the fan for automatic  
operation.  
FP1252  
Fig. 13 Fan location.  
1. Plug in the electrical cord.  
Fan  
2. Start gas fire - see lighting procedures.  
3. Turn on fan speed control.  
Temperature Sensor  
Speed  
Control  
4. Wait until the unit has warmed up sufficiently to  
activate the temperature sensor.  
Black  
White  
Ground  
5. Once fan starts, adjust speed control to desired fan  
speed. The fan will now automatically come on  
every time the fireplace is in operation. Should the  
fan not be needed simply turn off the speed control.  
FP394  
Fig. 14 Wiring diagram RN/RP.  
The appliance, when installed must be  
electrically connected and grounded in  
accordance with local codes or, in the  
absence of local codes, with the current  
CSA C22.1 Canadian Electrical Code.  
For U.S.A. installations, follow local  
codes and the national electrical code,  
ANSI/NFPA No. 70.  
Should this fan require servicing, the  
power supply must be disconnected. For  
rewiring of any replacement compo-  
nents refer to Figures 13 & 14.  
Fan Removal Instructions  
1. Turn off gas and electricity.  
2. Remove the front glass.  
3. Remove the logs.  
4. Remove burner assembly and rear log support plate.  
5. Remove the fan mounting nuts (2). (Fig. 13)  
6. Slip off the electrical connector at the motor.  
7. Lift out the fan.  
8. To reinstall, reverse procedure.  
10  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Operating Instructions  
General Glass Information  
Before remounting glass frame, brass  
trim must be installed. Refer to instruc-  
tions in "Frame Mounting" section.  
Only ceramic glass approved for use in Majestic  
fireplaces may be used for replacement on this  
fireplace.  
1. The use of substitute glass will void all product  
warranties.  
2. Care must be taken to avoid breakage of the glass.  
3. Under no circumstances should this fireplace be  
operated without front glass properly installed, or  
with any cracked or broken glass. Replacement of  
any glass assembly as supplied by the  
Glass Frame  
Screws  
manufacturer should be done by a licensed qualified  
service person.  
Machine Screws  
Open Access Door  
FP1373  
Louvre Removal  
Fig. 16 Remove glass frame.  
To remove top flat  
louvre pull louvre up  
Installation of Logs  
and then lift out.  
1 . Remove front glass. (Refer to "Glass Removal"  
section)  
2.  
Louvre  
2. Remove logs from packaging.  
1.  
3. Place rear log (JR4/KR4 or SR4) on rear bracket  
(ensure log is seated properly, leveled and  
centered to the unit), so it will not move from side to  
side and is firmly positioned on the bracket.  
Glass  
Panel  
FP444  
4. Slip front ember log (KR1or SR1) down in the front  
deflector.  
Fig. 15 Louvre removal.  
5. Place front left log (JR2/KR2 or SR2) on top  
burner, left side. Use log's bottom holes to locate it  
into the left bracket log locator studs.  
Glass Cleaning  
It will be necessary to clean the glass periodically.  
During start-up, condensation, which is normal, forms  
on the inside of the glass and causes lint, dust and  
other airborne particles to cling to the glass surface.  
Also initial paint curing may deposit a slight film on the  
glass. It is therefore recommended the glass be  
cleaned two or three times with a non-ammonia  
household cleaner and warm water (we recommend  
gas fireplace glass cleaner). After that the glass should  
be cleaned two or three times during each heating  
season depending on the circumstances present.  
6. Place front right log (JR3/KR3 or SR3) on top of  
burner, right side. Use log's bottom holes to locate  
it into the right bracket log locator studs.  
7. Place burner lava rock material on top of burner.  
(Refer to Figs. 17, 18 & 19 for proper location).  
8. Place top left log (JR5/KR5 or SR5) onto locator  
notches. Ensure log is secure.  
9. Place top right log (JR6/KR6 or SR6) onto locator  
notches. Ensure log is secure.  
Top logs must be placed properly into  
notches.  
Clean glass after first two weeks of  
operation.  
Glass Frame Removal  
1. Remove the top louvre. (Refer to "Louvre Removal"  
section)  
2. Open the access door.  
3. Remove two (2) machine screws from the bottom of  
glass frame. (Fig. 16)  
4. Lift up and unhook glass frame at the top.  
10000836  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Flame Adjustment (RN/RP Models)  
JR5  
JR6  
JR4  
For fireplaces equipped with HI/LO valve, flame adjust-  
ment is accomplished by rotating the HI/LO adjustment  
knob located near the center of the gas control.  
(Figs. 20 & 21)  
JR3  
JR2  
Turn  
counterclockwise  
to decrease  
HI  
Turn clockwise  
to increase  
LO  
flame height  
flame height  
Burner Lava Rock  
Placement  
KR1  
KR4  
LG279  
Fig. 20 Flame adjustment knob for Honeywell Valve.  
Fig. 17 RHE25 log and lava rock placement.  
Turn  
counterclockwise  
to increase  
KR5  
KR6  
Turn clockwise  
to decrease  
flame height  
flame height  
KR3  
KR1  
KR2  
Fig. 21 Flame adjustment knob for SIT Valve.  
Temperature Adjustment (TN/TP Models)  
The HI/LO reference on the control knob (Fig. 22) is to  
indicate a higher or lower temperature setting. This  
setting controls the heat by reducing then shutting off  
the flame after the desired temperature is reached.  
Position the control knob where it effectively maintains  
a comfortable room temperature.  
Burner Lava Rock  
Placement  
LG280  
Fig. 18 RHE32 log and lava rock placement.  
SR5  
SR6  
SR4  
SR2  
SR3  
SR1  
Burner Lava Rock  
Placement  
Fig. 22 Temperature adjustment knob for TN/TP models.  
LG281  
Fig. 19 RHE42 log and lava rock placement.  
Flame Characteristics  
It is important to periodically perform a visual check of  
the pilot and the burner flames. Compare them to  
Figure 23 and Figure 24 or 25. If any of the flames  
appear abnormal, call a service person.  
Large Lava Rock Placement  
The large lava rock provided with this fireplace must be  
placed on the firebox base on either side of the burner  
assembly.  
Under no circumstances should these  
lava rock be placed on top of the burner  
assembly.  
12  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
First Firing  
Upon completing the gas line connection, a small  
amount of air will be in the lines. When first lighting unit  
with pilot light, it will take a few minutes to purge  
themselves of air. Once the purging is complete, the  
pilot and burner will light and operate as indicated in  
the instruction manual. Subsequent lightings of the  
heater will not require such purging.  
LG282  
When lit for the first time, the appliance will emit a  
Fig. 23 Correct burner flame appearance for RHE25 and  
RHE32 models.  
slight odor for awhile. This is due to paint and  
lubricants used in the manufacturing process. After  
each lighting, vapor may condense and fog the glass;  
this moisture disappears within a few minutes of  
burning.  
LG283  
Fig. 24 Correct burner flame appearance for RHE42.  
PSE Pilot  
3/8" - 1/2"  
SIT Pilot  
F584-703  
Fig. 25 Correct pilot flame appearance.  
10000836  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Lighting And Operating Instructions  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING:If you do not follow these instructions exactly, a fire or explosion  
may result causing property damage, personal injury or loss of life.  
A. This heater has a pilot which must be lit manu-  
ally. When lighting the pilot follow these instruc-  
tions exactly.  
instructions.  
If you cannot reach your gas supplier, call  
the Fire Department  
B. BEFORE LIGHTING smell all around the heater  
area for gas. Be sure to smell next to the floor  
because some gas is heavier than air and will  
settle on the floor.  
C. Use only your hand to push in or turn the gas  
control knob. Never use tools. If the knob will not  
push in or turn by hand, do not try to repair it, call a  
qualified service technician. Applying force or any  
attempted repair may result in a fire or explosion.  
WHAT TO DO IF YOU SMELL GAS  
Do not try to light any fireplace  
Do not touch any electric switch  
Do not use any phone in your building  
D. Do not use this fireplace if any part has been under  
water. Immediately call a qualified service techni-  
cian to inspect the heater and to replace any part of  
the control system and any gas control which has  
been under water.  
Immediately call your gas supplier from a  
neighbor's phone. Follow the gas supplier's  
Lighting Instructions  
1. STOP! Read the safety information above.  
2. Turn off all electrical power to the fireplace.  
3. For MN/MP/TN/TP appliances ONLY, go on to  
Step 4. For RN/RP appliances turn the On/Off  
switch to “OFF” position or set thermostat to  
lowest level.  
10. Push the control knob all the way in and hold.  
Immediately light the pilot by repeatedly depress-  
ing the piezo spark ignitor until a flame appears.  
Continue to hold the control knob in for about one  
(1) minute after the pilot is lit. Release knob and it  
will pop back up. Pilot should remain lit. If it goes  
out, repeat steps 5 through 8.  
4. Open control access panel.  
5. Push in gas control knob slightly and turn  
clockwise  
to "OFF".  
3/8" - 1/2"  
OFF  
PILOT  
Honeywell  
Euro SIT  
SIT NOVA  
If knob does not pop up when released, stop  
and immediately call your service technician or  
gas supplier.  
6. Wait five (5) minutes to clear out any gas. Then  
smell for gas, including near the floor. If you  
smell gas, STOP! Follow "B" in the safety  
information above. If you do not smell gas, go  
to the next step.  
7. Remove glass door before lighting pilot. (See  
Glass Frame Removal section).  
8. Visibly locate pilot by the main burner.  
9. Turn knob on gas control counterclockwise  
to "PILOT".  
If after several tries, the pilot will not stay lit,  
turn the gas control knob to "OFF" and call your  
service technician or gas supplier.  
11. Replace glass door.  
12. Turn gas control knob to “ON” position.  
13. For RN/RP appliances turn the On/Off switch to  
“ON” position or set thermostat to desired setting.  
14. Turn on all electrical power to the fireplace.  
To Turn Off Gas To Heater  
1. Turn the On/Off switch to Off position or set the  
thermostat to lowest setting.  
3. Open control access panel.  
4. Push in gas control knob slightly and turn  
2. Turn off all electric power to the fireplace if  
service is to be performed.  
clockwise  
5. Close control access panel.  
to "OFF". Do not force.  
14  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Troubleshooting the Gas Control System  
SIT NOVA 820 Millivolt Valve  
NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the Onposition.  
WARNING: Before doing any gas control service work, remove glass front.  
SYMPTOM  
POSSIBLE CAUSES  
CORRECTIVE ACTION  
1.Spark ignitor will not light  
A. Defective or misaligned  
electrode at pilot.  
Using a match, light pilot. If pilot lights, turn off  
pilot and push the red button again. If pilot will not  
light - check gap at electrode and pilot-should be  
1/8" to have a strong spark.  
B. Defective ignitor (Push Button)  
Push Piezo Ignitor Button. Check for spark at  
electrode and pilot. If no spark to pilot, and elec  
trode wire is properly connected, replace ignitor.  
2.Pilot will not stay lit after  
carefully following lighting  
instructions.  
A. Defective pilot generator  
(thermocouple), remote wall  
switch.  
Check pilot flame. Must impinge on thermo  
couple/thermopile. Note: this pilot burner assem  
bly utilizes both-a thermocouple and a thermopile.  
The thermocouple operates the main valve  
operation (On and Off). Clean and or adjust pilot for  
maximum flame impingement on thermopile and  
thermocouple.  
B. Defective automatic valve  
Turn valve knob to “Pilot”. Maintain flow to pilot;  
milivolt meter should read greater than 10 mV. If  
the reading is okay and the pilot does not stay on,  
replace the gas valve. Note: An interrupter block  
(not supplied) must be used to conduct this test.  
3.Pilot burning, no gas to  
main burner  
A. Wall switch or wires defective  
Check wall switch and wires for proper connec  
tions. Jumper wire accross terminals at wall  
switch, if burner comes on, replace defective wall  
switch. If okay, jumper wires across wall switch  
wires at valve, if burner comes on, wires are faulty  
or connections are bad.  
B. Thermopile may not be  
generating sufficient  
millivoltage.  
1. Be sure wire connections from thermopile at  
gas valve terminals are tight and thermopile is  
fully inserted into pilot bracket.  
2. One of the wall switch wires may be grounded.  
Remove wall switch wires from valve terminals if  
pilot now stays lit, trace wall switch wiring for  
ground. May be grounded to fireplace or gas  
supply.  
3. Check thermopile with millivolt meter. Take  
reading at thermopile terminals of gas valve.  
Should read 250-300 millivolts (minimum 150)  
while holding valve knob depressed in pilot  
position and wall switch “Off”. Replace faulty  
thermopile if reading is below specified minimum.  
C. Plugged burner orifice.  
Check burner orifices for debris and remove.  
D. Defective automatic valve  
operator.  
Turn valve knob to “On”, place wall switch to “On”  
millivolt meter should read greater than 100 mV. If  
the reading is okay and the burner does not come  
on, replace the gas valve.  
4.Frequent pilot outage  
problem.  
A. Pilot flame may be too low  
or blowing (high) causing the  
pilot safety to drop out.  
Clean and/or adjust pilot flame for maximum flame  
impingement on thermopile and thermocouple.  
B. Possible blockage of the vent  
terminal.  
Check the vent terminal for blockage (recycling the  
flue gases)  
10000836  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Troubleshooting the Gas Control System  
Eurosit 630 Gas Valve  
NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position.  
WARNING: Before doing any gas control service work, remove glass front.  
Symptom  
Possible Causes  
Corrective Action  
1. Spark ignitor will not light  
A. Defective or misaligned  
electrode at pilot.  
Using a match, light pilot. If pilot lights, turn off pilot and  
push the red button again. If pilot will not light - check  
gap at electrode and pilot-should be 1/8" to have a  
strong spark.  
B. Defective ignitor (Push Button)  
Push Piezo Ignitor Button. Check for spark at electrode  
and pilot. If no spark to pilot, and electrode wire is  
properly connected, replace ignitor.  
2. Pilot will not stay lit after  
carefully following lighting  
ment instructions.  
A. Defective pilot generator  
thermocouple.  
Check pilot flame. Must impinge on thermocouple.  
Clean and or adjust pilot for maximum flame impinge-  
on thermocouple.  
B. Defective automatic valve  
operator.  
Turn valve knob to "Pilot". Maintain flow to pilot;  
millivolt meter should read greater than 10 mV. If the  
reading is okay and the pilot does not stay on, replace  
the gas valve. Note: An interrupter block (not supplied)  
must be used to conduct this test.  
3. Pilot burning, no gas to  
burner, Valve knob "ON".  
A. Sensing bulb not in proper  
location.  
Make sure sensing bulb is located in bracket on the  
lower right hand side of unit.  
B. Temperature sensing bulb  
damaged or tubing to bulb  
kinked  
Carefully examine sensing bulb and capillery tube for  
damage. If tubing is kinked, replace gas valve.  
4. Frequent pilot outage  
problem.  
A. Pilot flame may be too low  
or blowing (high) causing the  
Clean and/or adjust pilot flame for maximum flame  
impingement on thermocouple.  
pilot safety to drop out.  
B. Possible leak in liner or seals.  
Check the venting for leaks or blockage.  
16  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Troubleshooting the Gas Control System  
Honeywell Millivolt Valve  
START  
CHECK  
Gas Supply On  
Supply Line Hooked Up  
Shutoff Valve Open  
NO  
YES  
Lockout Has Engaged. Wait  
60 Seconds And Try Again.  
For Spark At Electrode While  
Depressing Piezo 1/8" Gap To  
Pilot Hood Needed.  
Pilot Lights With  
Piezo Ignitor  
NO  
All Wiring Connections  
Replace Piezo Ignitor  
YES  
Pilot Stays Lit  
YES  
For Air In The Lines  
Thermopile Needs A Minimum  
325mv. Adjust Pilot Flame Height.  
All Wiring Connections.  
Replace Thermopile  
Thermocouple Needs A Minimum  
of 14mv.  
Defective Valve. Turn To Pilot,  
Meter Should Read Greater Than  
100 Mv. If Not, Replace.  
NO  
Valve Is Turned On  
On/off Switch Is Not Turned On.  
Watch For Grounded Wires!  
Thermopile Needs A Minimum  
325mv.  
Pilot Lights Main  
Burner  
NO  
Plugged Burner Orifice.  
YES  
System OK.  
10000836  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Maintenance  
Burner and Burner Compartment  
Visually inspect pilot. Brush or blow away any dust or  
lint accumulation. If pilot orifice is plugged, disassembly  
may be required to remove any foreign material from  
the orifice or tubing.  
It is important to keep the burner and the burner  
compartment clean. At least once per year the logs and  
lava rock/ember material should be removed and the  
burner compartment vacuumed and wiped out. Remove  
and replace the logs as per the instructions in this  
manual.  
To obtain proper operation, it is imperative the pilot and  
burner's flame characteristics are steady, not lifting or  
floating.  
Always handle the logs with care as they  
are fragile and may also be hot if the  
fireplace has been in use.  
Typically, the top 1/8" of the thermopile should be  
engulfed in the pilot flame. (Page 13, Fig. 25)  
Brass Cleaning  
Fan Assembly  
Clean the brass trim with a soft clean cloth, slightly  
dampened with lemon oil and buff with a soft dry cloth.  
Do not use brass polish or household cleaners as these  
products will damage the trim. Lemon oil can be  
obtained at supermarkets or hardware stores.  
The fan unit requires periodic cleaning. At least once  
per month in the operating season, open the lower  
louvre panels and wipe or vacuum the area around the  
fan to remove any build up of dust or lint.  
Cleaning the Standing Pilot  
Control System  
The burner and control system consists of:  
• main burner  
• gas orifice  
• pilot burner  
• thermopile  
• combination millivolt gas valve  
Most of these components may require only an occa-  
sional checkup and cleaning and some may require  
adjustment. If repair is necessary, it should be per-  
formed by a qualified technician.  
In order to properly clean the burner and pilot assembly,  
turn off the gas to the unit, remove the window frame  
panel and logs exposing the burner and pilot assembly.  
Clean all foreign materials from the top of the burner.  
Check to make sure that burner parts are clean.  
18  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
12  
19  
5
10 a/b  
18  
31  
30  
4a/b  
16  
11 a/b  
14  
20  
24 a/b  
8a/b  
27  
9 a/b  
i t  
6/7 a/b  
32  
28  
13 18  
17  
29  
15  
22a/b  
35  
25  
34  
3
2
36  
26  
OFF  
L
I
PILT  
O
H
38  
40  
21  
39a/b  
23 a/b  
33  
41a/b  
44  
42a/b  
OFF  
¥
43  
LED  
45  
1d  
1d  
1d  
1c  
1f  
1f  
1f  
1e  
1e  
1e  
1b  
1c  
1c  
1b  
1b  
1a  
1a  
1a  
0836  
Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and  
products at any time, without notice.  
RHE25/32/42 Series  
10000836  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
RHE25/32/42 Series (continued)  
Ref. Description  
RHE25  
10000191  
KR1  
RHE32  
57896  
KR1  
RHE42  
10000206  
SR1  
1. Log Set Complete  
1a. Log Ember Front  
1b. Log Front Left  
JR2  
KR2  
SR  
1c. Log Front Right  
JR3  
KR3  
SR3  
1d. Log Rear  
JR4  
KR4  
SR4  
1e. Log Top Left  
JR5  
KR5  
SR5  
1f. Log Top Right  
JR6  
KR6  
SR6  
2. Lava Rock (Package)  
3. Burner Lava Rock (Package)  
4a. Burner Complete with tiles Nat.  
4b. Burner Complete with tiles Prop.  
5. Ceramic Tile (Single)  
6a. Orifice Front Burner Nat.  
6b. Orifice Front Burner Prop.  
7a. Orifice Main Burner Nat.  
7b. Orifice Main Burner Prop  
8a. Orifice Pilot SIT Nat.  
8b. Orifice Pilot SIT Prop  
9a. Orifice Pilot PSE Nat.  
9b. Orifice Pilot PSE Prop.  
10a. Pilot Assembly SIT Nat.  
10b. Pilot Assembly SIT Prop.  
11a. Pilot Assembly PSE Nat.  
11b. Pilot Assembly PSE Prop.  
12. Pilot SIT  
10001454  
57897  
10000192  
10000193  
57803  
10001454  
57897  
57903  
57904  
57803  
10001454  
57897  
10000869  
10000870  
57803  
See Rating Plate for Orifice Size  
See Rating Plate for Orifice Size  
See Rating Plate for Orifice Size  
See Rating Plate for Orifice Size  
54273  
54273  
54272  
54273  
54272  
10001822  
10001823  
10000672  
10000673  
10001739  
10001740  
10001295  
10001824  
10001296  
57318  
54272  
10001822  
10001823  
10000672  
10000673  
10001739  
10001740  
10001295  
10001824  
10001296  
57318  
10001822  
10001823  
10000672  
10000673  
10001739  
10001740  
10001295  
10001824  
10001296  
57318  
13. Pilot w/ignitor and cable PSE  
14. Pilot Tubing w/fittings  
15. Manifold Tubing w/fittings  
16. Thermocouple w/ Interrupter SIT  
17. Thermocouple w/Interrupter PSE  
18. Thermopile  
54912  
54912  
54912  
10001828  
51827  
10001828  
51827  
10001828  
51827  
19. Electrode Ignitor w/cable SIT  
20. Ignitor Piezzo SIT  
10001297  
52464  
10001297  
52464  
10001297  
52464  
21. Ignitor Piezzo Honeywell  
22a. Valve SIT 820 Nat.  
22b. Valve SIT 820 Prop.  
23a. Valve Honeywell Nat.  
23b. Valve Honeywell Prop.  
24a. Valve Eurosit 630 Nat.  
24b. Valve Eurosit 630 Prop.  
25. Fan with Bracket  
20000062  
52677  
20000062  
52677  
20000062  
52677  
52678  
52678  
52678  
10001782  
10001759  
10001105  
10001106  
54103  
10001782  
10001759  
10001104  
10001102  
54103  
10001782  
10001759  
10001104  
10001102  
54103  
26. Electrical Cord (6ft.)  
27. Fan Temperature Sensor  
28. Speed Control  
51865  
51865  
51865  
51704  
51704  
51704  
51738  
51738  
51738  
20  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
RHE25/32/42 Series (continued)  
Ref. Description  
29. Speed Control Knob  
RHE25  
51882  
RHE32  
51882  
RHE42  
51882  
30. Glass with Gasket  
54595  
51735  
10000961  
57316  
31. Gasket Glass  
57316  
57316  
32. Frame Window  
54455  
57914  
10000837  
53606  
33. Remote Switch  
53606  
53606  
34. Remote Wire Harness w/ terminals  
35. Vent Safety Switch  
57265  
57265  
57265  
51866  
51866  
51866  
36. Vent Safety Switch Wiring Harness  
37. Ceramic Refractory Kit (Not Shown)  
38. Antennae HW 395783-1 RFN/RFP Valve  
39a. RF Valve 8310E - Natural  
39b. RF Valve 8310E - LP  
40. Thermopile - RF Valve  
41a. Pilot Orifice - Natural - RF  
41b. Pilot Orifice - LP - RF  
42a. Pilot Assembly - Natural (3 Way) RF  
42b. Pilot Assembly - LP (3 Way) RF  
43. Transmitter  
54849  
54849  
54849  
JT2TBO  
KT2TBO  
20003561  
20003719  
20003720  
20002400  
20000908  
20000907  
20002266  
20002268  
20002047  
20002541  
10003279  
10000851  
20003561  
20003719  
20003720  
20002400  
20000908  
20000907  
20002266  
20002268  
20002047  
20002541  
10003279  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
44. Cord Set  
45. Pilot Tube 1/8” x 24” long w/Fittings (PSE Pilot)  
10000836  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Optional Accessories  
the Zero Clearance Kit and the requirements of the Air  
Kit when planning out the installation.  
Ceramic Refractory  
Optional for RHE25 and RHE32  
Follow the instructions supplied with the Zero Clear-  
ance Kit carefully for proper installation.  
Model  
Description  
RHE25CR  
RHE32CR  
RHE42CR  
Ceramic Firebox Liner  
Ceramic Firebox Liner  
Ceramic Firebox Liner  
Remote Controls  
Optional remote control units are available to control  
different functions of the appliance.  
1. Remove front glass (Refer to Glass Frame Removal  
section)  
Model  
MRC1  
MRC2  
MRC3  
Function(s) Controlled  
ON/OFF  
ON/OFF and Temperature  
ON/OFF and Temperature control  
with a digital and a programmable  
24 hour clock  
2. Remove logs from unit.  
Logs may be hot!  
3. Remove refractory from packaging.  
IMT  
Wall mounted thermostat control  
Refractory are fragile and must be  
handled with care. Where at all possible,  
two hands should be used when  
handling.  
A Trim Options for RHE25  
A1 RHE25SSP, RHE25LP  
Trim Assembly  
4. Take center refractory and tilt so bottom edge slides  
into support angle in back of fireplace.  
RHE25SSP  
5. Now press center refractory to back side of fireplace  
and hold in place.  
1. Install trim channels (left and right sides). Use two  
screws to assemble each piece.  
6. Take left or right refractory and align it so leading  
edge faces outward. Place refractory in fireplace  
side and slide it back to support center refractory.  
2. Slide on the trim top channel and fasten it from the  
back side.  
3. Install the trim top deflector using two screws.  
7. Install metallic piece in the leading edge (RHE32  
only).  
4. Remove ALL plastic protective covering from brass  
trim.  
8. Repeat Step 6 and 7 for remaining side refractory.  
When side refractory is installed correctly,  
the center refractory will be supported by  
the side refractory.  
Side View  
9. Fasten top tab supports against refractory to hold  
sides in place.  
Trim Top  
Deflector  
Center  
Right Side  
Left Side  
Leading  
Edge  
Leading  
Trim Frame Top Section  
FP1261a  
Edge  
Bottom Edge  
Fig. 27 Trim top deflector.  
FP1278  
HE25LP  
Fig. 26 Ceramic refractory.  
1. To install the kit you do not have to remove any  
piece of brass, you just add the external pieces.  
Zero Clearance Kit  
For installations other than in existing woodburning  
fireplaces such as new construction or renovation  
projects, a Zero Clearance Kit must be used. The  
HEZC enables these inserts to be installed in combusti-  
ble environments. It is recommended that an Air Kit  
(AKZC) be installed whenever using a Zero Clearance  
Kit. Consideration must be given to the dimensions of  
2. Remove the frame trim from the unit if it is already  
installed.  
3. Install trim channels (left and right sides) by remov-  
ing the two screws that hold the side brass trim and  
put them back to hold both parts.  
4. Slide on the trim top channel and fasten it from the  
back side.  
22  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
5. Remove the two screws that hold the top brass trim.  
Trim Assembly  
6. Install the two brackets to the studs in the bottom of  
the top channel. Use the nuts supplied with top trim  
channel.  
1. Remove the front glass (see "Glass Frame Re-  
moval" section).  
2. Install top and bottom brass trim by using the short-  
est black screw. (Fig. 28 & 29)  
A flat louvre kit OR a bay window kit need  
to be chosen to complete the installation.  
3. Install bottom decorative plate by simply sliding it  
under the unit floor. No fastening is required for this  
installation. (Fig. 30) Be sure to remove protective  
cover.  
RHE25SSP & HE25LP Replacement Parts  
5
4. Install the bottom louvre assembly by fastening the  
hinges with four screws to the pre-punched holes in  
the cabinet.  
6
6
4
4
3
1
5. Re-install the front glass.  
6. Install the top louvre by using the hooks to hang it in  
place.  
2
Trim Top  
Screws  
FP1289  
Vermont Castings, Majestic Products reserves the right to make  
changes in design, materials, specifications, prices and discontinue  
colors and products at any time, without notice.  
Glass Frame  
IMPORTANT: Only trim panel assemblies approved  
by Vermont Castings, Majestic Products can be  
used on these products.  
ALL repair parts will be available from your local dealer.  
Trim Bottom  
FP1290  
When ordering, always give the following information:  
Model and serial number, part description with finish  
and part number.  
Fig. 28 Install top and bottom brass trim.  
Key Description  
RHE25SSP  
10001939  
55099  
55077  
55096  
-
HE25LP(1)  
Louvre  
1
2
3
4
5
6
7
Trim Frame Black  
-
Trim Top Deflector  
Trim Top Channel(1)  
Trim Side Channel  
Trim Top Channel  
Trim Side Channel  
-
NOTE: Position  
brass trim top as  
shown (small end up)  
to prevent heat  
discoloration.  
-
-
55097  
55080  
-
Glass Frame  
Fasteners Package  
(Not Shown)  
FP1291  
54618  
57633  
Fig. 29 Position brass trim to with small end up.  
(1) LP trim to be used with SSP trim.  
SSP trim dimensions are for openings smaller than  
26¹⁄₂" H x 38" W (673mm x 965mm).  
LP trim dimensions are for openings smaller than 29" H  
x 41" W (736mm x 1040mm).  
A2 HE25FP Trim  
For use with RHEDV25  
Bottom  
Decorative  
Plate  
HE25FP  
Flat face louvres with polished window  
brass trim  
FP1292  
Fig. 30 Slide bottom decorative plate under unit floor.  
10000836  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
2. Install the hanging brackets. (Fig. 34)  
HE25FP Replacement Parts  
3. Install bracket on each side of the cabinet. Fig. 38)  
4. Install the ceramic piece inside the bay window.  
1
2
3
4
5. Install the bay window by hanging it onto the lower  
tabs of the hanging brackets. (Fig. 35)  
6. Install top louvre by engaging the oblong holes with  
the upper tabs of the hanging brackets. (Fig. 36)  
7. Install brass trim to the steel frame. (Fig. 37)  
FP1293  
5
Vermont Castings, Majestic Products reserves the right to make  
changes in design, materials, specifications, prices and discontinue  
colors and products at any time, without notice.  
IMPORTANT: Only trim panel assemblies approved  
by Vermont Castings, Majestic Products can be  
used on these products.  
Fan Control Box  
KT205  
ALL repair parts will be available from your local dealer.  
Fig. 31 Remove fan control box.  
When ordering, always give the following information:  
Model and serial number, part description with finish  
and part number.  
Fan Control  
Box  
Key Description  
HE25FP  
55098  
55079  
54603  
54604  
52356  
57916  
1
2
3
4
5
6
Trim Window Top/Bottom  
Extension  
Bracket  
Trim Bottom Channel  
Top Louvre Assembly  
Bottom Louvre Assembly  
Hinge  
KT207  
Fasteners Package (Not Shown)  
Fig. 32 Attach the control box to the bracket and install  
bracket into the cabinet.  
A3 HE25BTKP  
For use with RHEDV25  
HE25BTKP Bay window kit with polished brass trim  
Do not remove existing glass with frame.  
Extension  
Knobs  
Trim Assembly  
KT204a  
1. Reposition controls.  
Fig. 33 Install the knob extensions. (RN/RP models Only)  
a. Remove the Fan Speed Control Box. (Fig. 31)  
b. Attach the Fan Speed Control Box to the Bracket  
(Fig. 32) and install the Bracket into the Cabinet.  
Hanging Bracket  
Only for RN/RP VALVE units:  
c. Install the Control Knob Extensions onto the  
appropriate Control Valve Knobs. (Fig. 33)  
On units fitted with a Honeywell brand control  
valve the location of the control knobs and the  
ignitor button may vary slightly from those  
shown in Figure 33. The Honeywell exten-  
sion pieces are visually different in design  
and are not interchangeable with the RN/RP  
knobs shown in Figure 33.  
KT209b  
Fig. 34 Hanging bracket alignment.  
24  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
HE25BTKP Replacement Parts  
1
11  
HI  
LO  
2
15  
16  
KT210a  
6
7
9
10  
Fig. 35 Hang the window grille or the steel frame onto the  
lower tabs of the hanging brackets.  
5
3
4
13  
12  
8
KT211a  
0801  
Fig. 36 Engage the slots in the upper grille top louvre with  
the upper tabs of the hanging brackets.  
17  
Vermont Castings, Majestic Products reserves the right to make  
changes in design, materials, specifications, prices and discontinue  
colors and products at any time, without notice.  
IMPORTANT: Only trim panel assemblies approved  
by Vermont Castings, Majestic Products can be  
used on these products.  
ALL repair parts will be available from your local dealer.  
When ordering, always give the following information:  
Model and serial number, part description with finish  
and part number.  
Key Description  
HE25BTKP  
1
Trim Window Top & Bottom  
(w/magnets)  
10000779  
10000780  
10000787  
10000786  
52356  
KT212a  
2
3
4
5
6
7
8
9
Top Louvre Assembly  
Bottom Louvre Assembly  
Control Door  
Fig. 37 Attach magnets and brass trim to the steel frame.  
Hinge  
Glass Side  
10000388  
10000389  
10000529  
Glass Front  
Ceramic Refractory Bay  
Extension Knob On/Off  
(only for RN/RP valves)  
55163  
10 Extension Knob Hi/Lo  
(only for RN/RP valves)  
55162  
1409129  
1409146  
57877  
11 Bracket Hanging Bay Window  
12 Bracket Extension Rheostat  
13 Bracket Mounting Bay Window  
14 Hardware Package (Not Shown)  
FP1270  
Fig. 38 Bracket for HEBTKP.  
10000530  
15 Extension Knob Hi/Lo  
(Honeywell Valve)  
20000006  
20000007  
20001427  
16 Extension Knob On/Off  
(Honeywell Valve)  
17 Extension Knob Piezo Ignitor  
(Honeywell Valve)  
10000836  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
3. Install the trim top deflector and use two (2) screws  
A4 Riser Kits  
to fasten it. (Fig. 40 & 41)  
For use with RHEDV25 (Refer to Page 34, Figure 55)  
1. Install the unit according to Homeowner’s Manual.  
2. Install the trim according to Installation Instructions.  
4. Remove ALL plastic protective covering from brass  
trim.  
Trim Top  
Channel  
3. Remove the two (2) screws at the bottom of the  
trim.  
4. Install the riser at the bottom of the trim. (Fig. 55)  
5. Fasten the trim with the same two (2) screws  
removed in Step 3.  
Trim  
Side  
Trim  
Channel  
Side  
Channel  
Riser Trim Dimensions  
Deflector  
Trim Top  
Length - A  
Height - B  
Depth - C  
Screw  
RHE25R1-Riser 1" 38.3" (973mm) 1" (25.6mm) 2.86" (72.8mm)  
RHE25R-2Riser 2" 38.3" (973mm) 2" (50.9mm) 2.89" (73.6mm)  
RHE25R5-Riser 5" 38.3" (973mm) 5" (127.9mm) 2.86" (72.8mm)  
FP1260  
Fig. 40 Install trim channels and trim top deflector.  
B Trim Options for RHE32  
Side View  
B1 RHESS, RHESL, RHESSD, RHESLD, &  
RHESXL Trims  
For use with RHEDV32  
Frame Assembly  
Trim Top Deflector  
RHESS, RHESL, RHESSD, RHESLD and RHESXL  
1. Lay Trim Top Facing and Trim Side Facings, face  
down on to an even surface such as a table or floor.  
Be sure not to scratch the painted surfaces.  
2. Install the nuts and bolts. (Fig. 39)  
Trim Frame Top  
Section  
FP1261a  
Fig. 41 Trim top deflector.  
RHESSD and RHESLD (Fig. 42)  
10/24 Screws  
Frame Top  
1. Install trim channels (left and right sides). Use two  
(2) screws to assemble each piece.  
2. Peel off plastic protective covering from top edges of  
the inner sides where they will be covered by the  
inner top trim facing.  
3. Place the trim facing inner top in place (do not fasten  
it yet). Peel off the plastic protective covering from  
the bottom edge.  
10/24 Nuts  
Left  
4. Install the trim top deflector and fasten it (will hold  
the inner top piece). Use two (2) screws to assemble  
them.  
Right Frame  
Frame  
FP1259  
5. Install trim channels (left and right sides). Use two  
(2) screws to assemble each piece.  
Fig. 39 Attache left and right frame to frame top.  
6. Slide on the trim top channel and fasten it from the  
back side.  
Trim Assembly  
RHESS, RHESL and RHESXL (Fig. 40)  
7. Remove ALL plastic protective covering from brass  
trim.  
1. Install trim channels (left and right sides). Use two  
(2) screws to assemble each piece.  
2. Slide on the trim top channel and fasten it from the  
back side.  
26  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Trim Top  
Channel  
Trim  
Side  
Channel  
Trim  
Side  
Channel  
Screw  
Trim  
Framing Inner Sides  
FP1262  
Screws  
Fig. 42 RHESSD and RHESLD trim assembly.  
FP1263  
Front View  
A flat louvre kit OR a bay window kit need  
Fig. 43 Frame mounting.  
to be chosen to complete the installation.  
Plastic on the trim must be removed  
before mounting onto the fireplace.  
Frame Mounting  
General Information  
Glass must be tightly pressed against the  
front of the frame in order to prevent  
screws from damaging glass edges.  
The Decorative Front Frame should be installed last  
after all other work, such as gas connections, venting,  
etc., has been completed and thoroughly checked and  
tested for operation, leaks and proper installation re-  
quirements.  
Fit decorative frame to the fireplace and fasten. (Fig. 43)  
10000836  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
RHESS, RHESL, RHESSD, RHESLD, RHESXL Trim Replacement Parts  
5
1
IMPORTANT: Only trim panel assemblies ap-  
proved by Vermont Castings, Majestic Products  
4
can be used on these products.  
ALL repair parts will be available from your local  
dealer.  
6
2
3
6
When ordering, always give the following informa-  
tion: Model and serial number, part description with  
finish and part number.  
7
9
8
FP1264  
Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and  
products at any time, without notice.  
Key Description  
RHESS(2)  
RHESL(3)  
RHESSD(3)  
RHESLD(3)  
RHESXL(4)  
1
2
Trim Frame Top, Flat Black  
57929  
57927  
57928  
17634  
50586  
50589  
-
57932  
57930  
57931  
17634  
50587  
50590  
-
57929  
57927  
57928  
17634  
17611  
17623  
17609  
17620  
17622  
55043  
57932  
57930  
57931  
17634  
17612  
17624  
17610  
17619  
17621  
55043  
57935  
57933  
57934  
17634  
52787  
52788  
-
Trim Frame Left, Flat Black  
Trim Frame Right, Flat Black  
Trim Top Deflector(1)  
3
4
5
Trim Top Channel(1)  
6
Trim Side Channel Left(1)  
Trim Facing Inner Top(1)  
Trim Facing Inner Left(1)  
Trim Facing Inner Right(1)  
Fasteners Package (Not Shown)  
7
8
-
-
-
9
-
-
-
10  
55043  
55043  
55043  
(1)Specify Finish (Antique or Polished Brass)  
(2)SS and SSD trim dimensions are for openings smaller than 26¹⁄₂"H x 38" W (673mm x 965mm)  
(3)SL and SLD trim dimensions are for openings smaller than 29"H x 41" W (736mm x 1040mm)  
(4)SXL trim dimensions are for openings smaller than 32"H x 43" W (813mm x 1092mm)  
28  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
RHEBXL  
B2 RHEBSL & RHEBXL Trims  
To install the kit you do not have to remove any  
piece of brass, just add the external pieces.  
For use with RHEDV32  
Remove the frame trim from the unit if it is already  
installed.  
Trim Assembly  
RHEBSL  
1. Install trim channels (left and right sides)by remov-  
ing the two (2) screws that hold the side brass trim  
and put them back to hold both parts.  
1. Install trim channels (left and right sides). Use two  
(2) screws to assemble each piece.  
2. Slide on the trim top channel and fasten it from the  
back side.  
2. Slide on the trim top channel and fasten it from the  
back side.  
3. Install the trim top deflector. Use two (2) screws to  
fasten it. (Fig. 44)  
3. Remove the two (2) screws that hold the top brass  
trim.  
4. Remove ALL plastic protective covering from brass  
trim.  
4. Install the two (2) brackets to the studs in the bottom  
of the top channel. Use the nuts supplied with the  
kit.  
Side View  
5. Reinstall the two (2) screws to hold the top trim  
channel.  
Trim Top Deflector  
Trim Frame Top  
Section  
FP1261a  
Fig. 44 Trim top deflector.  
RHEBSLP, RHEBSLA, RHEBXLP, RHEBXLA Trim Replacement Parts  
IMPORTANT: Only Trim Panel Assemblies Approved by  
Vermont Castings, Majestic Products Can Be Used on  
These Products.  
5
3
ALL repair parts will be available from your local dealer.  
When ordering, always give the following information:  
Model and serial number, part description with finish and  
part number;  
1
2
4
(1) RHEBXLP or RHEBXLA to be used with RHEBSLP  
or RHEBSLA trims.  
6
4
6
(2) SL trim dimensions are for openings smaller than  
27¹⁄₂"H x 40¹⁄₂" W (700mm x 1030mm)  
(4) XL trim dimensions are for openings smaller than  
30"H x 45⁵⁄₈" W (765mm x 1160mm)  
Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and  
products at any time, without notice.  
Key Description  
RHEBSLP  
57926  
17634-PB  
57864  
57862  
-
RHEBSLA  
57926  
17634-AB  
57844  
57843  
-
RHEBXLP(1)  
RHEBXLA(1)  
1
2
3
4
5
6
7
Trim Frame Flat Black  
-
-
Trim Top Deflector  
-
-
Trim Top Channel  
-
-
Trim Side Channel  
-
-
Trim Outer Top Channel  
Trim Outer Side Channel  
Fasteners Package (Not Shown)  
57861  
57863  
57633  
57845  
57846  
57633  
-
-
54618  
54618  
10000836  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
B3 RHEFA and RHEFP Trims  
For use with RHEDV32  
Trim Assembly  
1. Remove the front glass (Refer to "Glass Frame  
Removal" section).  
2. Install support window trim channel, top and bottom  
brass trim by using the shortest black screw. (Fig. 45  
& 46)  
Bottom  
Decorative  
Plate  
3. Install bottom decorative plate by simply sliding it  
under the unit floor. No fastening is required for this  
installation. (Fig. 47) Be sure to remove protective  
cover.  
FP1292  
Fig. 47 Slide bottom decorative plate under unit floor.  
RHEFA & RHEFP Trim Replacement Parts  
4. Install the bottom louvre assembly by fastening the  
hinges with four (4) screws to the pre-punched holes  
in the cabinet.  
1
2
3
5. Re-install the front glass.  
6. Install the top louvre by using the hooks to hang it in  
place.  
4
Trim Top  
Screws  
5
6
FP1296  
Vermont Castings, Majestic Products reserves the right to make  
changes in design, materials, specifications, prices and discontinue  
colors and products at any time, without notice.  
Glass Frame  
IMPORTANT: Only trim panel assemblies approved  
by Vermont Castings, Majestic Products can be  
used on these products.  
Trim Bottom  
ALL repair parts will be available from your local dealer.  
FP1295  
When ordering, always give the following information:  
Model and serial number, part description with finish  
and part number.  
Fig. 45 Install support window trim channel and top and  
bottom brass trim.  
Key Description  
RHEFA  
RHEFP  
1
Trim Window  
Top/Bottom  
52624-AB  
52624-PB  
Louvre  
2
Plate Decorative  
Bottom  
NOTE: Position  
brass trim top as  
shown (small end up)  
to prevent heat  
discoloration.  
17597-AB  
57905  
17597-PB  
57905  
3
4
Top Louvre Assembly  
Bottom Louvre  
Assembly  
57906  
57906  
Glass Frame  
5
Support Window  
Trim Channel  
57909  
52356  
57909  
52356  
FP1291  
6
7
Hinge  
Fig. 46 Position brass trim to with small end up.  
Fasteners Package  
(Not Shown)  
57916  
57916  
30  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
B4 HEBTKP, HESBTKP, HECBTK, HECBTKMB & HEBTA Trims  
For use with RHEDV32  
HECBTK  
Cast bay window and grilles in classic black trim kit  
HECBKMB Cast bay window and grilles in midnight black porcelain enamel trim kit  
HESBTKP Steel bay window with polished brass and cast grilles in classic black trim kit  
HEBTKP  
Steel bay window and bay louvres with polished brass trim kit  
Install the bay window after all other installation work has been completed, thoroughly checked and tested for opera-  
tion, leaks and proper installation requirements.  
Do not remove existing glass with frame  
HEBTKP  
HESBTKP  
HECBTK &  
HECBTKMB  
Fig. 48 Optional bay front windows available for use on the RHEDV32.  
2. Install the hanging brackets. (Fig. 52)  
HECBTKP, HECBTKMB and HESBTKP  
Trim Assembly  
3. Install the two (2) ceramic pieces inside the bay  
window. (Fig. 48)  
1. Reposition controls.  
4. Install the bay window by hanging it onto the lower  
tabs of the hanging brackets. (Fig. 53)  
a. Remove the Fan Speed Control Box (Fig. 49)  
b. Attach the Fan Speed Control Box to the Bracket  
(Fig. 50) and install the Bracket into the Cabinet.  
Only for RN/RP VALVE units:  
5. Install the upper grille by engaging the oblong holes  
with the upper tabs of the hanging brackets. (Fig.  
54)  
c. Install the Control Knob Extensions onto the  
appropriate Control Valve Knobs (Fig. 51)  
6. Install brass trim to the steel frame. (Fig. 55) (Only  
for HESBTKP trim).  
On units fitted with a Honeywell brand control  
valve the location of the control knobs and the  
ignitor button may vary slightly from those  
shown in Figure 51. The Honeywell exten-  
sion pieces are visually different in design  
and are not interchangeable with the RN/RP  
knobs shown in Figure 51.  
HEBTKP Trim Assembly  
1. Reposition controls.  
a. Remove the Fan Speed Control Box (Fig. 49)  
b. Attach the Fan Speed Control Box to the Bracket  
(Fig. 50) and install the Bracket into the Cabinet.  
Only for RN/RP VALVE units:  
c. Install the Control Knob Extensions onto the  
appropriate Control Valve Knobs. (Fig. 51)  
10000836  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
On units fitted with a Honeywell brand control  
Hanging Bracket  
valve the location of the control knobs and  
the ignitor button may vary slightly from those  
shown in Figure 51. The Honeywell extension  
pieces are visually different in design and are  
not interchangeable with the RN/RP knobs  
shown in Figure 51.  
2. Install the hanging brackets. (Fig. 52)  
3. Install bracket on each side of the cabinet. (Fig. 56)  
4. Install the two ceramic pieces inside the bay win-  
dow. (Fig. 48)  
5. Install the bay window by hanging it onto the lower  
tabs of the hanging brackets. (Fig. 51)  
KT209a  
Fig. 52 Hanging bracket alignment.  
6. Install top louvre by engaging the oblong holes with  
the upper tabs of the hanging brackets. (Fig. 54)  
7. Install brass trim to the steel frame. (Fig. 55)  
KT210  
Fig. 53 Hang the window grille or the steel frame onto the  
lower tabs of the hanging brackets.  
Fan Control Box  
KT205  
Fig. 49 Remove fan control box.  
KT211  
Fan Control  
Box  
Fig. 54 Engage the slots in the upper grille top louvre with  
the upper tabs of the hanging bracket.  
Extension  
Bracket  
KT207  
Fig. 50 Attach the control box to the bracket and install  
bracket into the cabinet.  
KT212a  
Fig. 55 Attach magnets and brass trim to the steel frame.  
Extension  
Knobs  
KT204a  
Fig. 51 Install the knob extensions. (RN/RP models Only)  
FP1270  
Fig. 56 Bracket for HEBTKP.  
32  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
HECBTK, HECBTKMB, HESBTKP, HEBTKP, HEBTA Trim Parts Replacement  
1
3
14  
3
13  
6
9
7
10  
5
8
4
6
2
5
7
20  
16  
18  
11  
12  
15  
HI  
LO  
19  
0801  
Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and  
products at any time, without notice.  
IMPORTANT: Only Trim Panel Assemblies Approved by Vermont Castings, Majestic Products Can Be Used on These Products.  
ALL repair parts will be available from your local dealer.  
When ordering, always give the following information: Model and serial number, part description with finish and part number;  
Key Description  
HECBTK  
-
HECBTKMB  
-
HESBTKP  
55188-PB  
-
HEBTKP  
55188-PB  
52828-PB  
57945  
HEBTA  
1
2
Trim Window Top/Bottom w/magnets  
55188-AB  
Plate Decorative Bottom  
Top Louvre (Grill) Assembly  
Bottom Louvre (Grill) Assembly  
Control Door  
-
-
52828-AB  
3
1301199  
-
1341199  
-
1301199  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4
57947  
5
1301200  
1301219  
1301218  
1301198  
1601971  
1601957  
55163  
55162  
57772  
1409129  
1409146  
-
1341200  
1341219  
1341218  
1341198  
1601971  
1601957  
55163  
55162  
57772  
1409129  
1409146  
-
1301200  
1301219  
1301218  
1409127  
1601971  
1601957  
55163  
57946  
6
Bottom Louvre Left  
-
7
Bottom Louvre Right  
-
8
Bay Window Frame  
1409127  
1601971  
1601957  
55163  
9
Glass Side  
10  
11  
12  
13  
14  
15  
16  
17  
18  
Glass Front  
Extension Knob ON/OFF (RN/RP)  
Extension Knob Hi/Lo (RN/RP)  
Ceramic Refractory Bay (Set)  
Bracket Hanging Bay Window  
Bracket Extension Rheostat  
Bracket Mounting Bay Window  
Hardware Pkg. (Not Shown)  
55162  
55162  
57772  
57772  
1409129  
1409146  
-
1409129  
1409146  
57877  
10000108  
10000108  
10000108  
10000108  
-
-
-
Extension Knob Hi/Lo  
(Honeywell Valve)  
20000006  
20000007  
20000006  
20000007  
20000006  
20000007  
20000006  
20000007  
19  
20  
21  
Extension Knob On/Off  
(Honeywell Valve)  
Extension Knob Piezo Ignitor  
(Honeywell Valve)  
20001427  
-
20001427  
-
20001427  
-
20001427  
52356  
Hinge  
-
10000836  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
Riser Trim Dimensions  
B5 Cast Trim Options  
Length A  
Height B  
Depth C  
Cast Surround and Flat Face  
HECBL Cast Surround Black  
HECBLUE Cast Surround Blue  
RHER1-Riser 1" 42" (1067mm) 1" (25.6mm) 2.55" (64.8mm)  
RHER2-Riser 2" 42" (1067mm) 2" (50.9mm) 2.58" (65.6mm)  
RHER5-Riser 5" 42" (1067mm) 5" (127.9mm) 2.58" (65.6mm)  
HECCG  
HECGR  
CSSP  
Cast Surround Charcoal Grey  
Cast Surround Green  
B8 Arch Door Kits  
Polished Brass Small Trim for  
Cast Surround  
HEADKA  
HEADKP  
Antique Brass Arch Door  
Polished Brass Arch Door  
CSLP  
Polished Brass Large Trim for Cast  
Surround (to be used with CSSP)  
C Trim Options for RHE42  
C1 RHE42SSP and RHE42LP Trims  
For use with RHEDV42  
B6 Freestanding Kits  
Convert Insert Into A Freestanding Stove  
NOTE: 1. Requires Bay Window Face Kit  
RHE42SSP Small surround, black with thin polished  
2. Vent starter kit FSHEDVSK must be in  
stalledtouseanyofthefreestandingshells.  
brass edge  
RHE42LP Large polished brass edge (to be used  
FSNVCSKB Classic Black Freestanding Cast Shell  
with RHE42SSP)  
FSNVCSKM Midnight Black Enamel Freestanding  
Cast Shell  
Trim Assembly  
RHE42SSP  
FSNVCSKG Green Enamel Freestanding Cast Shell  
1. Install trim channels (left and right sides). Use two  
(2) screws to assemble each piece.  
B7 Riser Kits  
1. Install the unit according to Homeowner’s Manual.  
2. Install the trim according to Installation Instructions.  
2. Slide on the trim top channel and fasten it from the  
back side.  
3. Install the trim top deflector. Use two (2) screws to  
fasten it. (Fig. 58)  
3. Remove the two (2) screws at the bottom of the  
trim.  
4. Remove ALL plastic protective covering from brass  
trim.  
4. Install the riser at the bottom of the trim. (Fig. 57)  
5. Fasten the trim with the same two (2) screws  
removed in Step 3.  
Side View  
NOTE: The riser kit should only be used with the  
RHEBSL & RHEBXL trim.  
Trim Kit  
Trim Top Deflector  
Trim Frame Top  
Section  
FP1261a  
Fig. 58 Trim top deflector.  
RHE42LP  
Riser  
Decorative  
Trim  
To install the kit you do not have to remove any piece  
of brass, you just add the external pieces.  
Remove the frame trim from the unit if it is already  
installed.  
A
B
C
FP1276  
Fig. 57 RHEBSL, RHEBXL trim kit.  
34  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
1. Install trim channels (left and right sides) by remov-  
C2 RHE42FP Trim  
ing the two (2) screws that hold the side brass trim  
and put them back to hold both parts.  
For use with RHEDV42  
2. Slide on the trim top channel and fasten it from the  
back side.  
RHE42FP Flat face louvres with polished window  
brass trim  
3. Remove the two (2) screws that hold the top brass  
trim.  
Trim Assembly  
4. Install the two (2) brackets to the studs in the bottom  
of the top channel. Use the nuts supplied with the kit.  
1. Remove the front glass (Refer to "Glass Frame  
Removal" section).  
5. Reinstall the two (2) screws to hold the top trim  
channel.  
2. Install top and bottom brass trim (Fig. 59 & Fig. 60)  
Use the shortest black screw.  
A flat louvre kit OR a bay window kit  
need to be chosen to complete the  
installation.  
4. Install bottom decorative plate by simply sliding it  
under the unit. No fastening is required for this  
installation. (Fig. 61) Be sure to remove the protec-  
tive plastic cover from the trim.  
RHE42SSP & RHE42LP Replacement Parts  
5. Install the bottom louvre assembly by fastening the  
hinges with four (4) screws to the pre-punched holes  
in the cabinet.  
4
3
5
5
3
2
6. Re-install the front glass.  
7. Install the top louvre assembly by using the hooks to  
hang it in place.  
1
7
Trim Top  
Screws  
FP1297  
Vermont Castings, Majestic Products reserves the right to make  
changes in design, materials, specifications, prices and discontinue  
colors and products at any time, without notice.  
Glass Frame  
IMPORTANT: Only Trim Panel Assemblies Approved by  
Vermont Castings, Majestic Products Can Be Used on These  
Products.  
Trim Bottom  
ALL repair parts will be available from your local dealer.  
FP1295  
When ordering, always give the following information: Model  
and serial number, part description with finish and part  
number;  
Fig. 59 Install support window trim channel and top and  
bottom brass trim.  
Key Description  
RHE42SSP  
RHE42LP(1)  
1
Frame Trim Kit  
(Metallic Black)  
10000931  
-
Louvre  
2
3
4
5
6
Trim Top Channel  
Trim Side Channel  
Trim Top Channel  
Trim Side Channel  
57508  
-
NOTE: Position  
brass trim top as  
shown (small end up)  
to prevent heat  
discoloration.  
57509  
-
-
-
57511  
57507  
Fasteners Package  
(Not Shown)  
Glass Frame  
54618  
-
-
7
Trim Top Deflector  
10000912  
FP1291  
Fig. 60 Position brass trim to with small end up.  
(1)LP trim to be used with SSP trim.  
SSP trim dimensions are for openings smaller than  
30³⁄₄" H x 42⁷⁄₈"W (781mm x 1089mm)  
LP trim dimensions are for openings smaller than  
33³⁄₁₆"H x 48"W (846mm x 1225mm)  
10000836  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
C3 RHE42BTKP  
For use with RHEDV42  
RHE42BTKP Bay window with polished brass trim  
Do not remove existing glass with frame.  
Bottom  
Decorative  
Plate  
Trim Assembly  
1. Reposition controls.  
FP1292  
a. Remove the Fan Speed Control Box. (Fig. 62)  
Fig. 61 Slide bottom decorative plate under unit floor.  
b. Attach the Fan Speed Control Box to the Bracket  
(Fig. 61) and install the Bracket into the Cabinet.  
RHE42FP Replacement Parts  
Only for RN/RP VALVE units:  
c. Install the Control Knob Extensions onto the  
appropriate Control Valve Knobs. (Fig. 64)  
1
2
3
On units fitted with a Honeywell brand control  
valve the location of the control knobs and the  
ignitor button may vary slightly from those  
shown in Figure 64. The Honeywell extension  
pieces are visually different in design and are  
not interchangeable with the RN/RP knobs  
shown in Figure 64.  
4
5
6
FP1296  
Vermont Castings, Majestic Products reserves the right to make  
changes in design, materials, specifications, prices and discontinue  
colors and products at any time, without notice.  
2. Install the hanging brackets. (Fig. 65)  
3. Install the two (2) ceramic pieces inside the bay  
window.  
IMPORTANT: Only trim panel assemblies approved  
by Vermont Castings, Majestic Products can be  
used on these products.  
4. Install the bay window by hanging it onto the lower  
tabs of the hanging brackets. (Fig. 66)  
5. Install top louvre by engaging the oblong holes with  
the upper tabs of the hanging brackets. (Fig. 67)  
ALL repair parts will be available from your local dealer.  
When ordering, always give the following information:  
Model and serial number, part description with finish  
and part number.  
6. Install brass trim to the steel frame. (Fig. 68)  
Key Description  
RHE42FP  
10000880  
10000915  
10000929  
1
2
3
Trim Window Top/Bottom  
Plate Decorative Bottom  
Top Louvre Assembly (Metallic Black)  
Fan Control Box  
4
Bottom Louvre Assembly  
(Metallic Black)  
KT205  
10000930  
52356  
Fig. 62 Remove fan control box.  
5
6
Hinge  
Hardware Package (Not Shown)  
57916  
Fan Control  
Box  
Extension  
Bracket  
KT207  
Fig. 63 Attach the control box to the bracket and install  
bracket into the cabinet.  
36  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vermont Castings, Majestic Products RHE Natural Vent Insert  
HE42BTKP Trim Replacement Parts  
1
12  
HI  
LO  
2
14  
Extension  
Knobs  
15  
KT204a  
11  
6
8
7
10  
Fig. 64 Install the knob extensions. (RN/RP models Only)  
Hanging Bracket  
3
9
4
13  
5
16  
Vermont Castings, Majestic Products reserves the right to make  
changes in design, materials, specifications, prices and discontinue  
colors and products at any time, without notice.  
KT209a  
Fig. 65 Hanging bracket alignment.  
IMPORTANT: Only trim panel assemblies approved  
by Vermont Castings, Majestic Products can be  
used on these products.  
ALL repair parts will be available from your local dealer.  
When ordering, always give the following information:  
Model and serial number, part description with finish  
and part number.  
KT210  
Fig. 66 Hang the window grille or the steel frame onto the  
Key Description  
HE42BTKP  
lower tabs of the hanging brackets.  
1
Trim Window Top & Bottom  
(w/magnets)  
57576  
2
3
Top Louvre Assembly (Metallic Black)  
10000932  
Bottom Louvre Assembly  
(Metallic Black)  
10000933  
10000934  
57551  
4
5
Control Door (Metallic Black)  
Plate Decorative Bottom  
Hinge  
KT211a  
6
52356  
Fig. 67 Engage the slots in the upper grille top louvre with  
the upper tabs of the hanging brackets.  
7
Glass Side  
57405  
8
Glass Front  
57406  
9
Ceramic Refractory Bay  
10000854  
10  
Extension Knob On/Off  
(only for RN/RP valves)  
55163  
11  
Extension Knob Hi/Lo  
(only for RN/RP valves)  
55162  
12  
13  
14  
Bracket Hanging Bay Window  
Bracket Extension Rheostat  
1409129  
1409146  
Extension Knob Hi/Lo  
(Honeywell Valve)  
20000006  
20000007  
15  
16  
17  
Extension Knob On/Off  
(Honeywell Valve)  
Extension Knob Piezo Ignitor  
(Honeywell Valve)  
KT212a  
20001427  
10000928  
Hardware Package (Not Shown)  
Fig. 68 Attach magnets and brass trim to the steel frame.  
10000836  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED LIFETIME WARRANTY  
PRODUCT COVERED BY THIS WARRANTY  
All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces  
equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.  
BASIC WARRANTY  
Any part and/or component replaced under the provisions of this  
warranty is covered for six months or the remainder of the original  
warranty, whichever is longest.  
The Vermont Castings, Majestic Products Company (hereinafter  
referred to collectively as the Company) warrants that your new  
Vermont Castings or Majestic Gas Fireplace/Stove is free from  
manufacturing and material defects for a period of one year from the  
date of purchase, subject to the following conditions and limitations.  
This warranty is limited to the repair of or replacement of part(s) found  
to be defective in material or workmanship, provided that such part(s)  
have been subjected to normal conditions of use and service, after  
said defect is confirmed by the Company’s inspection.  
EXTENDED LIFETIME WARRANTY  
Thecompanymay, at itsdiscretion, fullydischargeallobligationswith  
respect to this warranty by refunding the wholesale price of the  
defective part(s)  
The heat exchanger, where applicable, and combustion chamber of  
every Vermont Castings or Majestic gas product is warranted for life  
against through wall perforation. All appliances equipped with an  
Insta-Flame Ceramic Burner have limited lifetime coverage on the  
ceramic burner plaque. Warrantees are made to the original owner  
subject to proof of purchase and the conditions and limitations listed  
on this Warranty Document  
Any installation, labor, construction, transportation, or other related  
costs/expensesarisingfromdefectivepart(s), repair, replacement, or  
otherwise of same, will not be covered by this warranty, nor shall the  
Company assume responsibility for same. Further, the Company will  
not be responsible for any incidental, indirect, or consequential  
damages except as provided by law.  
COMPONENT WARRANTY  
CAST IRON: All external and internal cast iron parts are warranted for a  
period of three years.  
SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR  
LIMITATIONSOFINCIDENTALANDCONSEQUENTIALDAMAGES  
ORLIMITATIONSONHOWLONGANIMPLIEDWARRANTYLASTS,  
SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR  
CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC  
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY  
FROM STATE TO STATE.  
Note: On porcelain enamel finished external parts and accessories  
The Company offers no Warranty on chipping of enamel surfaces.  
Inspect all product prior to accepting it for any damage to the enamel.  
The salt air environment of coastal areas or a high humidity  
environment can be corrosive to the porcelain enamel finish. These  
conditions can cause rusting of the cast iron beneath the porcelain  
enamel finish, which will cause the finish to flake off.  
Allotherwarranties-expressedorimplied-withrespecttotheproduct,  
its components and accessories, or any obligations/liabilities on the  
part of the Company are hereby expressly excluded.  
Dye lot variations with replacement parts and/or accessories can  
occur and are not covered by warranty.  
The Company neither assumes, nor authorizes any third party to  
assume on its behalf, any other liabilities with respect to the sale of  
this Vermont Castings, Majestic product  
GLASS DOORS: Glass doors are covered for a period of one year.  
Glass doors are not warranted for breakage due to misuse or  
accident. Glass doors are not covered for discoloration or burned in  
stains due to environmental issues, or improper cleaning and  
maintenance.  
The warranties as outlined within this document do not apply to  
chimney components or other non Vermont Castings, Majestic  
accessories used in conjunction with the installation of this product..  
Damage to the unit while in transit is not covered by this warranty but  
is subject to claim against the common carrier. Contact the dealer  
from whom you purchased your fireplace/stove (do not operate the  
appliance as this might negate the ability to process the claim with the  
carrier).  
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be  
cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar  
mix and masonry cleaners may corrode the brass finish. The  
Company will not be responsible for, nor will it warrant any brass parts  
which are damaged by external chemicals or down draft conditions.  
The Company will not be responsible for:  
GAS VALVES: Gas valves are covered for a period of one year  
a) Down drafts or spillage caused by environmental conditions such  
as near-by trees, buildings, roof tops, hills, or mountains.  
b) Inadequate ventilation or negative air pressure caused by  
mechanical systems such as furnaces, fans, clothes dryers, etc.  
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and  
mechanical components of the burner assembly are covered for one  
year. All steel tube burners are warranted for one year.  
ACCESSORIES: Unless otherwise noted all components and Vermont  
Castings, Majestic Products company supplied accessories are covered  
for a period of one year.  
This warranty is void if:  
a) The fireplace has been operated in atmospheres contaminated  
by chlorine, fluorine, or other damaging chemicals.  
b) The fireplace has been subjected to prolonged periods of  
dampness or condensation  
c) Any damages to the fireplace, combustion chamber, heat  
exchangerorothercomponentsduetowater,orweatherdamage,  
which is the result of but not limited to, improper chimney/venting  
installation.  
CONDITIONS AND LIMITATIONS  
This new Vermont Castings or Majestic product must be installed by  
a competent, authorized, service contractor. A licensed technician,  
as prescribed by the local jurisdiction must perform any installation/  
service work. It must be installed and operated at all times in  
accordance with the Installation and Operating instructions furnished  
with the product. Any alteration, willful abuse, accident, or misuse of  
the product shall nullify this warranty.  
d) Any alteration, willful abuse, accident, or misuse of the product  
has occurred.  
This warranty is non-transferable, and is made to the original owner,  
provided that the purchase was made through an authorized supplier  
of the Company.  
IF WARRANTY SERVICE IS NEEDED…  
1) Contactyoursupplier. Makesureyouhaveyourwarranty,  
your sales receipt, and the model/serial number of your  
Vermont Castings, Majestic product.  
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK  
YOURSELF.  
ThecustomermustpayforanyAuthorizedDealerin-hometravelfees  
or service charges for in-home repair work. It is the dealers option  
whether the repair work will be done in the customer’s home or in the  
dealer’s shop.  
If upon inspection, the damage is found to be the fault of the  
manufacturer, repairs will be authorized at no charge to the customer  
parts and/or labor.  
38  
10000836  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Telex SONAR CIA 1000 User Manual
Topfield DVR TF4000PVR CoCI User Manual
Trane Thermostat VAV SVX02B EN User Manual
Transition Networks Cable Box C E 100BTX FRL 03 User Manual
Tripp Lite Network Card PDU1230 User Manual
Tripp Lite TV Cables N820 02M User Manual
ViewSonic Projector VS14116 User Manual
Villaware Crepe Maker Crpe Maker User Manual
Wagan Air Compressor 9916 User Manual
Walker Lawn Mower Model MT User Manual