Natural Vent Insert
Models: RHE25
RHE32
RHE42
Installation Instructions & Homeowner's Manual
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPOURS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.
• Do not touch any electric switch
• Do not use any phone in your building.
• Immediately call your gas supplier from your
neighbours phone. Follow the gas suppliers
instructions.
• Installation and service must be performed by
a qualified installer, service agency or your gas
supplier.
• If you cannot reach your gas supplier call the
fire department.
Vermont Castings, Majestic Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
CERTIFIED
I
INSTALLER: DO NOT DISCARD THIS MANUAL - Leave For Homeowner
10000836 8/03 Rev.3
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Installation Instructions
This gas appliance should be installed by a qualified installer
IMPORTANT:
in accordance with local building codes and with current CSA-
B149.1 Installation codes for Gas Burning Appliances and
Equipment.
PLEASE REVIEW THE FOLLOWING CAREFULLY
Remove any plastic from trim parts before turning the
fireplace ON.
For U.S.A Installations follow local codes and/or the current
National Fuel Gas Code. ANSI Z223.1.
It is normal for fireplaces fabricated of steel to give
off some expansion and/or contraction noises during
the start up or cool down cycle. Similar noises are
found with your furnace heat exchanger or car
engine.
FOR SAFE INSTALLATION AND OPERATION OF YOUR
MAJESTIC GAS FIREPLACE INSERT PLEASE NOTE THE
FOLLOWING:
1. This appliance gives off high temperatures and should be
located out of high traffic areas and away from furniture
and draperies.
2. Children and adults should be alerted to the hazards of the
high surface temperatures of this appliance and should
stay away to avoid burns or ignition of clothing.
3. Children should be carefully supervised when they are in
the same room as your appliance.
4. Under no circumstances should this appliance be modified.
Parts removed for servicing should be replaced prior to
operating this appliance again.
5. Installation and any repairs to this appliance should be
carried out by a qualified service person. A professional
service person should be contacted to inspect this appli-
ance annually. Make it a practice to have all of your gas
appliances checked annually. More frequent cleaning may
be required due to excess lint and dust from carpeting,
bedding material, etc.
It is not unusual for your Majestic gas fireplace to
give off some odor the first time it is burned. This is
due to the curing of the paint and any undetected oil
from the manufacturing process.
Please ensure that your room is well ventilated -
open all windows.
It is recommended that you burn your Majestic
fireplace for a least six (6) hours the first time you
use it. If optional fan kit has been installed, place fan
in the "OFF" position during this time.
Locating Your Gas Fireplace Insert with
Zero Clearance Kit
6. Control compartments, burners and air passages in this
appliance should be kept clean and free of dust and lint.
Make sure that the gas valve and pilot light are turned off
before you attempt to clean this unit.
7. The venting system (chimney) of this appliance should be
checked at least once a year and if needed your venting
system should be cleaned.
X
A
B
E
C
D
X
8. Keep the area around your appliance clear of combustible
materials, gasoline and other flammable vapor and liquids.
This appliance should not be used as a drying rack for
clothing, nor should Christmas stockings or decorations be
hung in the area of it.
9. Under no circumstances should any solid fuels (wood, coal,
paper or cardboard etc.) be used in this appliance.
10.The flow of combustion and ventilation air must not be
obstructed in any way.
X
F
FP1249
Fig 1. Locating unit with zero clearance kit.
A) Flat on wall
C) Island
B) Cross corner
D) *Room divider
E) *Flat on wall corner
F) Chase installation
11.These appliances are certified for installation in a solid fuel
burning fireplace unless using the model HEZC Zero
Clearance kit. When the Zero Clearance kit is used, and
the appliance is installed directly on carpeting, vinyl tile or
any combustible material other than wood, the appliance
must be installed on a metal or wood panel extending the
full width and depth of the appliance.
NOTE: (Fig. 1)
* When you install your Majestic fireplace in (D) Room divider
or (E) Flat on wall corner positions, a minimum of 6" (X)
(153mm) clearance must be maintained from the perpendicu-
lar wall and the outer edge of the trim.
Insert Applications
12.This appliance requires adequate ventilation and
combustion air to operate properly.
Before installing the gas fireplace insert, consideration
must be given to the functioning needs of the fireplace.
The size of the fireplace cavity, the design of the chimney
for effective venting should be determined. The
availability of the gas supply as well as electricity for the
insert fan must be confirmed.
Proposition 65 Warning: Fuels used in gas,
woodburning or oil fired appliances, and the products
of combustion of such fuels, contain chemicals known
to the State of California to cause cancer, birth defects
and other reproductive harm.
California Health & Safety Code Sec. 25249.6
10000836
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Fireplace Dimensions
F
B
D
E
A
G
H
Maintain 1"
(25mm) Clearance
to B-Vent
Zero Clearance Kit
C
Minimum Fireplace
Insert Opening
M
P
N
L
O
U
S
K
Q
V
T
1"
(25mm)
Air Inlet Channel
R
Gas Inlet Knock-out
1 = SS or SSD Trim
Q - Fireplace Opening Height T - Firebox Width at Insert Depth(s)
2 = SL or SLD Trim
3 = SXL Trim
R - Fireplace Opening Width
S - Depth of Insert
U - Firebox Depth at Insert Back Height (V)
V - Insert Back Height
4 = BSL Trim
5 = BXL Trim
RHE25
26³⁄₄" (680mm)
RHE32
RHE42
(781mm)
A-1
B-1
A-2
B-2
A-3
B-3
A-4
B-4
A-5
26³⁄₈"
38³⁄₈"
29"
(676mm)
(975mm)
(737mm)
30³⁄₄"
T
R
I
38¹⁄₂"
(978mm)
43¹⁄₈"
(1095mm)
29¹⁄₄"
(743mm)
33³⁄₈"
(848mm)
43¹⁄₂"
(1105mm)
41¹⁵⁄₁₆" (1065mm)
48¹⁄₄"
(1225mm)
M
-
-
-
-
-
-
-
-
-
-
33"
44"
(838mm)
(1118mm)
(712mm)
(1041mm)
(775mm)
-
-
-
-
-
-
-
-
-
-
28"
40⁷⁄₈"
30¹⁄₂"
B-5
C
-
-
46"
28³⁄₄"
(1171mm)
(730mm)
-
-
25¹⁄₄"
(641mm)
31"
(787mm)
F
I
D
E
F
17"
13³⁄₄"
15"
(432mm)
(349mm)
(381mm)
(489mm)
(445mm)
(889mm)
(676mm)
(216mm)
(952mm)
(486mm)
17¹⁄₄"
15⁵⁄₈"
17¹⁄₈"
20¹⁄₂"
20"
(438mm)
(397mm)
(435mm)
(521mm)
(508mm)
(889mm)
(676mm)
(216mm)
(952mm)
(486mm)
20¹⁄₈"
17³⁄₄"
21"
(511mm)
(451mm)
(533m)
R
E
P
L
A
C
E
G
H
K
L
19¹⁄₄"
17¹⁄₂"
35"
23¹⁄₄"
22³⁄₄"
39¹⁄₄"
31¹⁄₈"
8¹⁄₂"
(590mm)
(578mm)
(1000mm)
(790mm)
(216mm)
(954mm)
(553mm)
35"
26⁵⁄₈"
8¹⁄₂"
26⁵⁄₈"
8¹⁄₂"
M
N
O
37¹⁄₂"
19¹⁄₈"
37¹⁄₂"
19¹⁄₈"
37¹⁄₂"
21³⁄₄"
P
Q
27¹⁄₄"
17³⁄₄"
(692mm)
(451mm)
27¹⁄₄"
21"
(692mm)
(533mm)
25³⁄₄"
23¹⁄₄"
(654mm)
(591mm)
M
I
N
I
M
U
M
O
P
E
N
I
N
G
R
S
T
25"
13³⁄₄"
17¹⁄₂"
14"
(635mm)
(349mm)
(445mm)
(356mm)
(451mm)
28"
16"
(711mm)
(407mm)
(451mm)
(419mm)
(514mm)
29"
18"
737mm)
(457mm)
(524mm)
(533mm)
(584mm)
17³⁄₄"
16¹⁄₂"
20¹⁄₄"
20⁵⁄₈"
21"
U
V
17³⁄₄"
23"
4
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
The use of wallpaper adjacent to this
fireplace is not recommended, as the
high heat given off by this fireplace may
adversely effect the binders in the adhe-
sive used to apply the wallpaper.
Mantels
When the insert is being installed into a woodburning
fireplace the minimum the mantel can be above the
fireplace is governed by local building codes applicable
to woodburning fireplaces. Consult local authorities
having jurisdiction for these clearances.
37¹⁄₄" (946mm)
For applications requiring the use of a Zero Clearance
Kit, the minimum a mantel can protrude above the
fireplace is 24" (610mm) from the top of the upper
louvres. The maximum mantel depth is 8" (200mm).
(Fig. 2)
35"
The underside of the mantel will get quite
warm. Use only finishes which are heat
resistant and do not discolour.
(889mm)
24" Min.
(610mm)
19¹⁄₈" (486mm)
(RHE25/32)
21³⁄₄" (553mm)
(RHE42)
Air Inlet Channel
27¹⁄₄" (692mm) (RHE25/32)
25³⁄₄" (654mm) (RHE42)
Dry
Wall
Finish Wall
Decorative Trim Kit
FP1325
FP1351a
Fig. 2 Minimum mantel height above fireplace.
Fig. 3 RHE insert framing dimensions.
Framing & Finishing
Combustion Air
For Zero Clearance Kit applications it is important to
determine the finished facing material before beginning
to frame. This will allow for the thickness of the
finishing material between the frame and the fireplace
trim.
It is very important that an adequate air supply is
available when the unit is being operated. Since most
homes of today are tightly sealed and insulated,
additional make-up air is usually necessary.
This fireplace has been designed to operate by
drawing air in from the front and outer perimeters of
the fireplace. The air provides combustion air ensuring
a clean burning flame, dilution air for proper venting, as
well as, the air which the fan circulates over the
firebox/heat exchanger system.
Similarily, consideration must be given to the 1"
(25mm) depth of the air inlet channel sitting on the
fireplace base. Finishing material for the hearth should
be flush with the top of the air inlet channel.
If the fireplace is installed at floor level a non-
combustible hearth must extend a minimum 12"
(305mm) in front of the fireplace.
Insulating around the fireplace will result in overheating
and possible malfunctioning of the circulating fan.
If the fireplace is recessed into the wall and at least 12"
(305mm) above floor level, no hearth is required.
A (3" for RHE25, 4" for RHE32 and RHE42) diameter
Class "B" vent must be used when installing the
fireplace insert along with the Zero Clearance Kit. The
vent system must be a minimum height of 12' (3.7m).
10000836
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Zero Clearance Applications
The installation of your Majestic Fireplace
must conform with local codes, or in the
absence of local codes, with National Fuel Gas
Code, ANSI Z223.1 latest edition, or CSA-
B149.1 Installation Code. (EXCEPTION: Do
not derate this appliance for elevations up to
4,500 ft (1,370m). Maintain the manifold
pressure at 3.5" w.c. for Natural Gas and 10.0"
w.c. for LP gas.)
An alternate air supply is recommended
with this component.
For installations other than in existing woodburning
fireplaces such as new construction or renovation
projects, a Zero Clearance Kit must be used. The kit
enables these inserts to be installed in combustible
environments. It is recommended that an Air Kit
(AKZC) be installed whenever using a Zero Clearance
Kit. Consideration must be given to the dimensions of
the Zero Clearance Kit and the requirements of the Air
Kit when planning the installation.
High Elevations
Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the
current ANSI Z223.1 and/or local codes having
jurisdiction.
Gas Specifications
Max. Min.
Input Input
Model
Fuel
Gas Control
Millivolt HI/LO
Millivolt HI/LO
Manual HI/LO
Manual HI/LO
Millivolt HI/LO
Millivolt HI/LO
Btu/h Btu/h
22,000 15,400
22,000 16,500
22,000 15,400
22,000 16,500
30,000 21,000
30,000 22,500
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370m).
RHE25RN
Natural Gas
RHE25RP Propane Gas
RHE25MN Natural Gas
RHE25MP Propane Gas
RHE3RN Natural Gas
RHE32RP Propane Gas
Preparation
RHE32TN
RHE32TP
RHE42RN
Natural Gas Thermostat HI/LO 30,000 21,000
Propane Gas Thermostat HI/LO 30,000 22,500
Before beginning, remove the glass frame from the
fireplace. Also check to make sure there is no hidden
damage to the fireplace. Take a minute and plan out
the gas, vent and electrical supply. Refer to Glass
Frame Removal section.
Natural Gas
Millivolt HI/LO
Millivolt HI/LO
40,000 28,000
37,000 27,750
RHE42RP Propane Gas
RHE42TN
RHE42TP
Natural Gas Thermostat HI/LO 40,000 28,000
Propane Gas Thermostat HI/LO 37,000 27,750
Gas Line Installation
Gas Inlet & Manifold Pressures
When purging the gas line, the front
glass must be removed.
Natural
LP
11.0" W.C.
Minimum Inlet Pressure
Maximum Inlet Pressure
Manifold Pressure
5.5" W.C.
The gas pipeline can be brought into the fireplace base
from the right side. It is most convenient to install it
from the right side into the gas fittings provided.
14.0" W.C. 14.0" W.C.
3.5" W.C. 10.0" W.C.
Do not use this appliance if any part of it
has been under water. Immediately call a
qualified service technician to inspect the
unit and replace any part of the control
which has been under water.
When using copper or flex connector use only
approved fittings. Always provide a union when using
black iron pipe so that gas line can be easily
disconnected for burner or fan servicing. Refer to gas
specifications for pressure details and ratings.
These gas inserts are approved for installation in
solid fuel burning masonry or zero clearance
fireplaces.
The gas line connection can be made of either properly
tinned 3/8" copper pipe, 3/8" rigid pipe or an approved
flex connector.
The gas control inlet is 3/8" N.P.T. therefore the 1/2"
rigid gas line must be reduced to 3/8" N.P.T. Typical
installation layout for rigid pipe is shown following. (Fig.
4)
RHE25 / RHE32 / RHE42
Certified To
ANSI Z 21.88-2002 / CSA 2.33-2002
Vented Gas Fireplace Heaters
6
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Installation of Remote Switch
for RN/RP Gas Valves
1/2" Gas Supply
1/2" x 3/8" Reducer
3/8" x 3/8" Shut Off
Valve
1. Thread wire through gas inlet opening on the right
side of fireplace. Do not cut wire or insulation on
metal edges.
3/8" Union
2. Slide switch assembly from the back, between
subframe and trim, then fasten the screw. (Fig. 6)
3. For left side installation reverse switch position in
bracket and repeat Step 2. (Fig. 7)
3/8" Nipple
FP1278
4. Connect wiring to gas valve (Fig. 8a & b) and switch.
Fig. 4 Typical gas supply installation.
During any pressure testing of the gas line system,
when the test pressures are to exceed 1/2 psi (3.5 kpa)
the fireplace and its gas valve must not be connected
to that system.
Right Side Installation
Left Side Installation
Trim Top
Trim Left
Side
Trim Right
Side
At test pressures equal to or less than 1/2 psi, the gas
valve of the fireplace may be connected to the gas line,
but must be in the closed position.
ON/OFF Switch
Assembly
Wiring from
Millivolt Gas
Valve
Some municipalities have additional local codes, it is
always best to consult the local authority and the CSA-
B149.1 installation code in Canada.
Trim
Screw
Trim
Screw
FOR U.S.A Installations consult the current National
Fuel Gas Code, ANSI Z223.1
ON/OFF Switch Assembly
FP1253
Fig. 6 Slide switch assembly between subframe and trim.
Always check for gas leaks with a mild soap
and water solution. Do not use an open
flame for leak testing.
Bracket Switch
Manifold Gas
Outlet
Brass
Brass Plug
Thermostat
Bulb
Plug
Pressure
Regulator
Gas Inlet
Thermocouple Inlet
ON/OFF
Switch
Pilot Tube Entry
Pilot
Control Knob
FP1254
Adjustment
Screw
Control Knob
Fig. 7 For left side installation, reverse switch position in
bracket.
i t
Valve
Minimum Rate Screw
(Nonadjustable)
Thermopile
HV118
Fig. 5 On fireplaces equipped with the Eurosit 630 gas
valves, there are brass plugs in two of the holes. These
plugs are not to be removed. The gas inlet hole has a plastic
cap in it. Remove the plastic cap and connect your gas
supply line at this point.
The MN/MP valve control used on the
RHE25 does not include the thermostat
bullb as shown in Figure 5.
FP382a
Fig. 8a ON/OFF switch or millivolt thermostat.
10000836
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Venting and Installation
Installer must attach red warning plate
with screws supplied with the gas fire-
place insert to the inside of the firebox of
the fireplace into which the gas fireplace
insert is installed.
WARNING
This fireplace has been converted for use with
gas only and cannot be used for burning wood
or solid fuels unless all original parts have been
replaced and the fireplace has been re-approved
by the authority having jurisdiction.
FP1218a
Fig. 8b ON/OFF switch wiring.
If a remote wall switch is required for this
fireplace installation, do not wire wall
switch to 120V power supply.
Cutting any sheet metal parts of the
fireplace, in which the gas fireplace insert
is to be installed, is prohibited.
Venting Instructions
If the factory-built fireplace has no gas
access hole(s) provided, an access hole
of 1¹⁄₂" (37.5mm) or less may be drilled
through the lower sides or bottom of the
firebox in a proper workmanship like
manner. This access hole must be
plugged with a noncombustible insulation
after the gas supply line has been
installed.
Canadian Installations:
The venting system must be installed in accordance
with the current CSA-B149.1 installation code, and the
authority having jurisdiction.
U.S.A. Installations:
The venting system must be installed in accordance
with the current National Fuel Gas Code, ANSI Z223.1.
Minimum clearances to combustible materials is 1"
(25mm) for B Vent (use of single wall vent is not
allowed).
Ensure there are no obstructions to side
air passages of decorative trim once
installed on insert.
As with any natural draft appliances, the vent cap must
always extend a minimum of 2' (610mm) above any
structure within a 10' (3m) horizontal plane. (Fig. 9)
WARNING
Some factory built fireplaces have air passages
on face of fireplace for zero clearance capabili-
ties. All trim kits are designed so as to allow
airflow to these passages. Under no circum-
stances should these passages be blocked.
0 To 10’
2’ Min.
0 To 10’
(3m)
3’
Min.
2’
1. The Majestic gas inserts are designed for recessed
installations into solid fuel Masonry or Factory Built
Noncombustible fireplaces that have been installed
in accordance with the National, Provincial, State
and local building codes.
3’
(610mm)
Min.
(914mm)
Min.
Reference
Point
AC246a
2. Measure for minimum fireplace opening requirement
on Page 4 of this installation manual. (If firebrick
[refractory] is removed from a factory built
fireplace in order to gain minimum gas fireplace
insert opening requirements, a minimum of 1/4"
(6.4mm) air space is required between the gas
insert fireplace's outer casing and the inner wall
of the factory built fireplace).
Fig. 9 Example of the 2', 3', 10' rule.
A minimum 12' (3.7m) vent height is
required to effectively vent this fireplace.
3. To assure top performance, safety and efficiency, all
inserts must be installed with an approved 4"
diameter flue liner, with exception of RHE25, which
should be installed with an approved 3" liner,as per
CSA-B.149 or National Fuel Code ANSI Z223.
8
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
4. Flue damper must be fully blocked in the open
Chimney Liner
Damper
Damper
position or removed for installation.
Chimney
Liner
5. The chimney must be clean and in good working
order and constructed of noncombustible materials.
Flue
Collar Plate
Clamp
Screw
Clamp
6. Make sure that all chimney cleanouts fit properly so
air cannot leak into the chimney.
7. Glass door, screen kits and log grate may be
removed for installation of insert into factory built
fireplace.
8. Install the insert without the trim frame and make all
gas, venting and electrical connections.
FP1354
Fig. 10 Remove flue collar plate and attach to flue collar.
9. Install decorative trim frame. Please refer to Frame
Assembly and Mounting instructions on this manual.
Test Chimney Draw
A "Chimney Draw" test must be made before the
installation is complete.
Common Flue Installations
In some areas it is possible to vent more than one gas
fireplace into the same flue. You must ensure the flue
being shared has the proper capacity to handle both
fireplaces. Check installation codes for venting capacity
information.
1. Close all doors and windows in the home and start
exhaust fans in the kitchen and bathroom.
2. Light unit and operate for 5 minutes.
3. Hold an ignited match or cigarette in front of the
unit. Refer to Figure 11 for the location of the draft
hood opening.
4. Check to make sure smoke from the match or
cigarette is drawn into the fireplace. If it is not, turn
the unit off and check for causes creating the lack of
adequate draft.
As always it is best to check with the authority having
jurisdiction prior to commencement of the installation.
Liner Installation
Insert liner from top of chimney through the damper
opening and attach to 3" flue collar (for RHE25); 4" flue
collar (for RHE32 & RHE42). For best results use
three (3) sheet metal screws and a hose clamp.
Test for Draft at This Location
For natural draft inserts packing fibreglass insulation
around the liner in the damper area will isolate the
fireplace cavity from the chimney and prevent drafts
and noises during operation.
In case the fireplace opening is only minimum height
(17¹⁄₂" for RHE25) (20" for RHE32) (22³⁄₄" for RHE42)
and access from the front is not possible, remove the
flue collar plate - unscrew and slide out from the back
of the unit. Now attach the liner to the flue collar, lift up
and simply slide flue collar plate back onto the unit top.
It is important the plate is completely inserted and the
front screw is fastened again in order to line up the flue
outlet and the liner properly. (Fig. 10)
FP1371
Fig. 11 Hold an ignited match in front of fireplace.
Vent Safety System
These inserts are equipped with a vent safety shut
down switch. This switch is factory installed, wired and
tested. Check and make sure the switch and wires are
in the proper position. The safety switch is heat acti-
vated and wired in series with the pilot system. (Fig. 12)
If fireplace lintel is wider than 8"
(205mm), the height of the fireplace
opening must be 25" (635mm) to allow
for a 90° offset elbow to be installed.
Bracket
Draft Relief Opening
This insert is equipped with a draft-relief opening which
receives its dilution air supply through the opening
behind the louvres. These openings must not be
obstructed or altered in any way. (Fig. 11)
Vent Safety
Switch
FP1372
Fig. 12 Vent safety switch.
10000836
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Operation of this fireplace when not
connected to a properly installed and
maintained venting system or tampering
with the vent safety shutoff system can
Stud
result in carbon monoxide (CO)
poisoning and possibly death.
Thermal Sensor is
attached to burner
base
Fan is installed
at the back of
the air intake
box
Fan Kit
Stud
Valve
115 Volt, 60 Hz. 56W
Fan Speed Control/Junction Box
The fan kit includes the following: fan, temperature
sensor, speed control and a 6 ft. cord. The following
explains how to start and set the fan for automatic
operation.
FP1252
Fig. 13 Fan location.
1. Plug in the electrical cord.
Fan
2. Start gas fire - see lighting procedures.
3. Turn on fan speed control.
Temperature Sensor
Speed
Control
4. Wait until the unit has warmed up sufficiently to
activate the temperature sensor.
Black
White
Ground
5. Once fan starts, adjust speed control to desired fan
speed. The fan will now automatically come on
every time the fireplace is in operation. Should the
fan not be needed simply turn off the speed control.
FP394
Fig. 14 Wiring diagram RN/RP.
The appliance, when installed must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electrical Code.
For U.S.A. installations, follow local
codes and the national electrical code,
ANSI/NFPA No. 70.
Should this fan require servicing, the
power supply must be disconnected. For
rewiring of any replacement compo-
nents refer to Figures 13 & 14.
Fan Removal Instructions
1. Turn off gas and electricity.
2. Remove the front glass.
3. Remove the logs.
4. Remove burner assembly and rear log support plate.
5. Remove the fan mounting nuts (2). (Fig. 13)
6. Slip off the electrical connector at the motor.
7. Lift out the fan.
8. To reinstall, reverse procedure.
10
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Operating Instructions
General Glass Information
Before remounting glass frame, brass
trim must be installed. Refer to instruc-
tions in "Frame Mounting" section.
Only ceramic glass approved for use in Majestic
fireplaces may be used for replacement on this
fireplace.
1. The use of substitute glass will void all product
warranties.
2. Care must be taken to avoid breakage of the glass.
3. Under no circumstances should this fireplace be
operated without front glass properly installed, or
with any cracked or broken glass. Replacement of
any glass assembly as supplied by the
Glass Frame
Screws
manufacturer should be done by a licensed qualified
service person.
Machine Screws
Open Access Door
FP1373
Louvre Removal
Fig. 16 Remove glass frame.
To remove top flat
louvre pull louvre up
Installation of Logs
and then lift out.
1 . Remove front glass. (Refer to "Glass Removal"
section)
2.
Louvre
2. Remove logs from packaging.
1.
3. Place rear log (JR4/KR4 or SR4) on rear bracket
(ensure log is seated properly, leveled and
centered to the unit), so it will not move from side to
side and is firmly positioned on the bracket.
Glass
Panel
FP444
4. Slip front ember log (KR1or SR1) down in the front
deflector.
Fig. 15 Louvre removal.
5. Place front left log (JR2/KR2 or SR2) on top
burner, left side. Use log's bottom holes to locate it
into the left bracket log locator studs.
Glass Cleaning
It will be necessary to clean the glass periodically.
During start-up, condensation, which is normal, forms
on the inside of the glass and causes lint, dust and
other airborne particles to cling to the glass surface.
Also initial paint curing may deposit a slight film on the
glass. It is therefore recommended the glass be
cleaned two or three times with a non-ammonia
household cleaner and warm water (we recommend
gas fireplace glass cleaner). After that the glass should
be cleaned two or three times during each heating
season depending on the circumstances present.
6. Place front right log (JR3/KR3 or SR3) on top of
burner, right side. Use log's bottom holes to locate
it into the right bracket log locator studs.
7. Place burner lava rock material on top of burner.
(Refer to Figs. 17, 18 & 19 for proper location).
8. Place top left log (JR5/KR5 or SR5) onto locator
notches. Ensure log is secure.
9. Place top right log (JR6/KR6 or SR6) onto locator
notches. Ensure log is secure.
Top logs must be placed properly into
notches.
Clean glass after first two weeks of
operation.
Glass Frame Removal
1. Remove the top louvre. (Refer to "Louvre Removal"
section)
2. Open the access door.
3. Remove two (2) machine screws from the bottom of
glass frame. (Fig. 16)
4. Lift up and unhook glass frame at the top.
10000836
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Flame Adjustment (RN/RP Models)
JR5
JR6
JR4
For fireplaces equipped with HI/LO valve, flame adjust-
ment is accomplished by rotating the HI/LO adjustment
knob located near the center of the gas control.
(Figs. 20 & 21)
JR3
JR2
Turn
counterclockwise
to decrease
HI
Turn clockwise
to increase
LO
flame height
flame height
Burner Lava Rock
Placement
KR1
KR4
LG279
Fig. 20 Flame adjustment knob for Honeywell Valve.
Fig. 17 RHE25 log and lava rock placement.
Turn
counterclockwise
to increase
KR5
KR6
Turn clockwise
to decrease
flame height
flame height
KR3
KR1
KR2
Fig. 21 Flame adjustment knob for SIT Valve.
Temperature Adjustment (TN/TP Models)
The HI/LO reference on the control knob (Fig. 22) is to
indicate a higher or lower temperature setting. This
setting controls the heat by reducing then shutting off
the flame after the desired temperature is reached.
Position the control knob where it effectively maintains
a comfortable room temperature.
Burner Lava Rock
Placement
LG280
Fig. 18 RHE32 log and lava rock placement.
SR5
SR6
SR4
SR2
SR3
SR1
Burner Lava Rock
Placement
Fig. 22 Temperature adjustment knob for TN/TP models.
LG281
Fig. 19 RHE42 log and lava rock placement.
Flame Characteristics
It is important to periodically perform a visual check of
the pilot and the burner flames. Compare them to
Figure 23 and Figure 24 or 25. If any of the flames
appear abnormal, call a service person.
Large Lava Rock Placement
The large lava rock provided with this fireplace must be
placed on the firebox base on either side of the burner
assembly.
Under no circumstances should these
lava rock be placed on top of the burner
assembly.
12
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
First Firing
Upon completing the gas line connection, a small
amount of air will be in the lines. When first lighting unit
with pilot light, it will take a few minutes to purge
themselves of air. Once the purging is complete, the
pilot and burner will light and operate as indicated in
the instruction manual. Subsequent lightings of the
heater will not require such purging.
LG282
When lit for the first time, the appliance will emit a
Fig. 23 Correct burner flame appearance for RHE25 and
RHE32 models.
slight odor for awhile. This is due to paint and
lubricants used in the manufacturing process. After
each lighting, vapor may condense and fog the glass;
this moisture disappears within a few minutes of
burning.
LG283
Fig. 24 Correct burner flame appearance for RHE42.
PSE Pilot
3/8" - 1/2"
SIT Pilot
F584-703
Fig. 25 Correct pilot flame appearance.
10000836
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Lighting And Operating Instructions
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit manu-
ally. When lighting the pilot follow these instruc-
tions exactly.
instructions.
• If you cannot reach your gas supplier, call
the Fire Department
B. BEFORE LIGHTING smell all around the heater
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call a
qualified service technician. Applying force or any
attempted repair may result in a fire or explosion.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any fireplace
• Do not touch any electric switch
• Do not use any phone in your building
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the heater and to replace any part of
the control system and any gas control which has
been under water.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
Lighting Instructions
1. STOP! Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. For MN/MP/TN/TP appliances ONLY, go on to
Step 4. For RN/RP appliances turn the On/Off
switch to “OFF” position or set thermostat to
lowest level.
10. Push the control knob all the way in and hold.
Immediately light the pilot by repeatedly depress-
ing the piezo spark ignitor until a flame appears.
Continue to hold the control knob in for about one
(1) minute after the pilot is lit. Release knob and it
will pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 8.
4. Open control access panel.
5. Push in gas control knob slightly and turn
clockwise
to "OFF".
3/8" - 1/2"
OFF
PILOT
Honeywell
Euro SIT
SIT NOVA
•
If knob does not pop up when released, stop
and immediately call your service technician or
gas supplier.
6. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you
smell gas, STOP! Follow "B" in the safety
information above. If you do not smell gas, go
to the next step.
7. Remove glass door before lighting pilot. (See
Glass Frame Removal section).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise
to "PILOT".
•
If after several tries, the pilot will not stay lit,
turn the gas control knob to "OFF" and call your
service technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. For RN/RP appliances turn the On/Off switch to
“ON” position or set thermostat to desired setting.
14. Turn on all electrical power to the fireplace.
To Turn Off Gas To Heater
1. Turn the On/Off switch to Off position or set the
thermostat to lowest setting.
3. Open control access panel.
4. Push in gas control knob slightly and turn
2. Turn off all electric power to the fireplace if
service is to be performed.
clockwise
5. Close control access panel.
to "OFF". Do not force.
14
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Troubleshooting the Gas Control System
SIT NOVA 820 Millivolt Valve
NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position.
WARNING: Before doing any gas control service work, remove glass front.
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE ACTION
1.Spark ignitor will not light
A. Defective or misaligned
electrode at pilot.
Using a match, light pilot. If pilot lights, turn off
pilot and push the red button again. If pilot will not
light - check gap at electrode and pilot-should be
1/8" to have a strong spark.
B. Defective ignitor (Push Button)
Push Piezo Ignitor Button. Check for spark at
electrode and pilot. If no spark to pilot, and elec
trode wire is properly connected, replace ignitor.
2.Pilot will not stay lit after
carefully following lighting
instructions.
A. Defective pilot generator
(thermocouple), remote wall
switch.
Check pilot flame. Must impinge on thermo
couple/thermopile. Note: this pilot burner assem
bly utilizes both-a thermocouple and a thermopile.
The thermocouple operates the main valve
operation (On and Off). Clean and or adjust pilot for
maximum flame impingement on thermopile and
thermocouple.
B. Defective automatic valve
Turn valve knob to “Pilot”. Maintain flow to pilot;
milivolt meter should read greater than 10 mV. If
the reading is okay and the pilot does not stay on,
replace the gas valve. Note: An interrupter block
(not supplied) must be used to conduct this test.
3.Pilot burning, no gas to
main burner
A. Wall switch or wires defective
Check wall switch and wires for proper connec
tions. Jumper wire accross terminals at wall
switch, if burner comes on, replace defective wall
switch. If okay, jumper wires across wall switch
wires at valve, if burner comes on, wires are faulty
or connections are bad.
B. Thermopile may not be
generating sufficient
millivoltage.
1. Be sure wire connections from thermopile at
gas valve terminals are tight and thermopile is
fully inserted into pilot bracket.
2. One of the wall switch wires may be grounded.
Remove wall switch wires from valve terminals if
pilot now stays lit, trace wall switch wiring for
ground. May be grounded to fireplace or gas
supply.
3. Check thermopile with millivolt meter. Take
reading at thermopile terminals of gas valve.
Should read 250-300 millivolts (minimum 150)
while holding valve knob depressed in pilot
position and wall switch “Off”. Replace faulty
thermopile if reading is below specified minimum.
C. Plugged burner orifice.
Check burner orifices for debris and remove.
D. Defective automatic valve
operator.
Turn valve knob to “On”, place wall switch to “On”
millivolt meter should read greater than 100 mV. If
the reading is okay and the burner does not come
on, replace the gas valve.
4.Frequent pilot outage
problem.
A. Pilot flame may be too low
or blowing (high) causing the
pilot safety to drop out.
Clean and/or adjust pilot flame for maximum flame
impingement on thermopile and thermocouple.
B. Possible blockage of the vent
terminal.
Check the vent terminal for blockage (recycling the
flue gases)
10000836
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Troubleshooting the Gas Control System
Eurosit 630 Gas Valve
NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position.
WARNING: Before doing any gas control service work, remove glass front.
Symptom
Possible Causes
Corrective Action
1. Spark ignitor will not light
A. Defective or misaligned
electrode at pilot.
Using a match, light pilot. If pilot lights, turn off pilot and
push the red button again. If pilot will not light - check
gap at electrode and pilot-should be 1/8" to have a
strong spark.
B. Defective ignitor (Push Button)
Push Piezo Ignitor Button. Check for spark at electrode
and pilot. If no spark to pilot, and electrode wire is
properly connected, replace ignitor.
2. Pilot will not stay lit after
carefully following lighting
ment instructions.
A. Defective pilot generator
thermocouple.
Check pilot flame. Must impinge on thermocouple.
Clean and or adjust pilot for maximum flame impinge-
on thermocouple.
B. Defective automatic valve
operator.
Turn valve knob to "Pilot". Maintain flow to pilot;
millivolt meter should read greater than 10 mV. If the
reading is okay and the pilot does not stay on, replace
the gas valve. Note: An interrupter block (not supplied)
must be used to conduct this test.
3. Pilot burning, no gas to
burner, Valve knob "ON".
A. Sensing bulb not in proper
location.
Make sure sensing bulb is located in bracket on the
lower right hand side of unit.
B. Temperature sensing bulb
damaged or tubing to bulb
kinked
Carefully examine sensing bulb and capillery tube for
damage. If tubing is kinked, replace gas valve.
4. Frequent pilot outage
problem.
A. Pilot flame may be too low
or blowing (high) causing the
Clean and/or adjust pilot flame for maximum flame
impingement on thermocouple.
pilot safety to drop out.
B. Possible leak in liner or seals.
Check the venting for leaks or blockage.
16
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Troubleshooting the Gas Control System
Honeywell Millivolt Valve
START
CHECK
Gas Supply On
Supply Line Hooked Up
Shutoff Valve Open
NO
YES
Lockout Has Engaged. Wait
60 Seconds And Try Again.
For Spark At Electrode While
Depressing Piezo 1/8" Gap To
Pilot Hood Needed.
Pilot Lights With
Piezo Ignitor
NO
All Wiring Connections
Replace Piezo Ignitor
YES
Pilot Stays Lit
YES
For Air In The Lines
Thermopile Needs A Minimum
325mv. Adjust Pilot Flame Height.
All Wiring Connections.
Replace Thermopile
Thermocouple Needs A Minimum
of 14mv.
Defective Valve. Turn To Pilot,
Meter Should Read Greater Than
100 Mv. If Not, Replace.
NO
Valve Is Turned On
On/off Switch Is Not Turned On.
Watch For Grounded Wires!
Thermopile Needs A Minimum
325mv.
Pilot Lights Main
Burner
NO
Plugged Burner Orifice.
YES
System OK.
10000836
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Maintenance
Burner and Burner Compartment
Visually inspect pilot. Brush or blow away any dust or
lint accumulation. If pilot orifice is plugged, disassembly
may be required to remove any foreign material from
the orifice or tubing.
It is important to keep the burner and the burner
compartment clean. At least once per year the logs and
lava rock/ember material should be removed and the
burner compartment vacuumed and wiped out. Remove
and replace the logs as per the instructions in this
manual.
To obtain proper operation, it is imperative the pilot and
burner's flame characteristics are steady, not lifting or
floating.
Always handle the logs with care as they
are fragile and may also be hot if the
fireplace has been in use.
Typically, the top 1/8" of the thermopile should be
engulfed in the pilot flame. (Page 13, Fig. 25)
Brass Cleaning
Fan Assembly
Clean the brass trim with a soft clean cloth, slightly
dampened with lemon oil and buff with a soft dry cloth.
Do not use brass polish or household cleaners as these
products will damage the trim. Lemon oil can be
obtained at supermarkets or hardware stores.
The fan unit requires periodic cleaning. At least once
per month in the operating season, open the lower
louvre panels and wipe or vacuum the area around the
fan to remove any build up of dust or lint.
Cleaning the Standing Pilot
Control System
The burner and control system consists of:
• main burner
• gas orifice
• pilot burner
• thermopile
• combination millivolt gas valve
Most of these components may require only an occa-
sional checkup and cleaning and some may require
adjustment. If repair is necessary, it should be per-
formed by a qualified technician.
In order to properly clean the burner and pilot assembly,
turn off the gas to the unit, remove the window frame
panel and logs exposing the burner and pilot assembly.
Clean all foreign materials from the top of the burner.
Check to make sure that burner parts are clean.
18
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
12
19
5
10 a/b
18
31
30
4a/b
16
11 a/b
14
20
24 a/b
8a/b
27
9 a/b
i t
6/7 a/b
32
28
13 18
17
29
15
22a/b
35
25
34
3
2
36
26
OFF
L
I
PILT
O
H
38
40
21
39a/b
23 a/b
33
41a/b
44
42a/b
OFF
¥
43
LED
45
1d
1d
1d
1c
1f
1f
1f
1e
1e
1e
1b
1c
1c
1b
1b
1a
1a
1a
0836
Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and
products at any time, without notice.
RHE25/32/42 Series
10000836
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
RHE25/32/42 Series (continued)
Ref. Description
RHE25
10000191
KR1
RHE32
57896
KR1
RHE42
10000206
SR1
1. Log Set Complete
1a. Log Ember Front
1b. Log Front Left
JR2
KR2
SR
1c. Log Front Right
JR3
KR3
SR3
1d. Log Rear
JR4
KR4
SR4
1e. Log Top Left
JR5
KR5
SR5
1f. Log Top Right
JR6
KR6
SR6
2. Lava Rock (Package)
3. Burner Lava Rock (Package)
4a. Burner Complete with tiles Nat.
4b. Burner Complete with tiles Prop.
5. Ceramic Tile (Single)
6a. Orifice Front Burner Nat.
6b. Orifice Front Burner Prop.
7a. Orifice Main Burner Nat.
7b. Orifice Main Burner Prop
8a. Orifice Pilot SIT Nat.
8b. Orifice Pilot SIT Prop
9a. Orifice Pilot PSE Nat.
9b. Orifice Pilot PSE Prop.
10a. Pilot Assembly SIT Nat.
10b. Pilot Assembly SIT Prop.
11a. Pilot Assembly PSE Nat.
11b. Pilot Assembly PSE Prop.
12. Pilot SIT
10001454
57897
10000192
10000193
57803
10001454
57897
57903
57904
57803
10001454
57897
10000869
10000870
57803
See Rating Plate for Orifice Size
See Rating Plate for Orifice Size
See Rating Plate for Orifice Size
See Rating Plate for Orifice Size
54273
54273
54272
54273
54272
10001822
10001823
10000672
10000673
10001739
10001740
10001295
10001824
10001296
57318
54272
10001822
10001823
10000672
10000673
10001739
10001740
10001295
10001824
10001296
57318
10001822
10001823
10000672
10000673
10001739
10001740
10001295
10001824
10001296
57318
13. Pilot w/ignitor and cable PSE
14. Pilot Tubing w/fittings
15. Manifold Tubing w/fittings
16. Thermocouple w/ Interrupter SIT
17. Thermocouple w/Interrupter PSE
18. Thermopile
54912
54912
54912
10001828
51827
10001828
51827
10001828
51827
19. Electrode Ignitor w/cable SIT
20. Ignitor Piezzo SIT
10001297
52464
10001297
52464
10001297
52464
21. Ignitor Piezzo Honeywell
22a. Valve SIT 820 Nat.
22b. Valve SIT 820 Prop.
23a. Valve Honeywell Nat.
23b. Valve Honeywell Prop.
24a. Valve Eurosit 630 Nat.
24b. Valve Eurosit 630 Prop.
25. Fan with Bracket
20000062
52677
20000062
52677
20000062
52677
52678
52678
52678
10001782
10001759
10001105
10001106
54103
10001782
10001759
10001104
10001102
54103
10001782
10001759
10001104
10001102
54103
26. Electrical Cord (6ft.)
27. Fan Temperature Sensor
28. Speed Control
51865
51865
51865
51704
51704
51704
51738
51738
51738
20
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
RHE25/32/42 Series (continued)
Ref. Description
29. Speed Control Knob
RHE25
51882
RHE32
51882
RHE42
51882
30. Glass with Gasket
54595
51735
10000961
57316
31. Gasket Glass
57316
57316
32. Frame Window
54455
57914
10000837
53606
33. Remote Switch
53606
53606
34. Remote Wire Harness w/ terminals
35. Vent Safety Switch
57265
57265
57265
51866
51866
51866
36. Vent Safety Switch Wiring Harness
37. Ceramic Refractory Kit (Not Shown)
38. Antennae HW 395783-1 RFN/RFP Valve
39a. RF Valve 8310E - Natural
39b. RF Valve 8310E - LP
40. Thermopile - RF Valve
41a. Pilot Orifice - Natural - RF
41b. Pilot Orifice - LP - RF
42a. Pilot Assembly - Natural (3 Way) RF
42b. Pilot Assembly - LP (3 Way) RF
43. Transmitter
54849
54849
54849
JT2TBO
KT2TBO
20003561
20003719
20003720
20002400
20000908
20000907
20002266
20002268
20002047
20002541
10003279
10000851
20003561
20003719
20003720
20002400
20000908
20000907
20002266
20002268
20002047
20002541
10003279
--
--
--
--
--
--
--
--
--
--
--
44. Cord Set
45. Pilot Tube 1/8” x 24” long w/Fittings (PSE Pilot)
10000836
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Optional Accessories
the Zero Clearance Kit and the requirements of the Air
Kit when planning out the installation.
Ceramic Refractory
Optional for RHE25 and RHE32
Follow the instructions supplied with the Zero Clear-
ance Kit carefully for proper installation.
Model
Description
RHE25CR
RHE32CR
RHE42CR
Ceramic Firebox Liner
Ceramic Firebox Liner
Ceramic Firebox Liner
Remote Controls
Optional remote control units are available to control
different functions of the appliance.
1. Remove front glass (Refer to Glass Frame Removal
section)
Model
MRC1
MRC2
MRC3
Function(s) Controlled
ON/OFF
ON/OFF and Temperature
ON/OFF and Temperature control
with a digital and a programmable
24 hour clock
2. Remove logs from unit.
Logs may be hot!
3. Remove refractory from packaging.
IMT
Wall mounted thermostat control
Refractory are fragile and must be
handled with care. Where at all possible,
two hands should be used when
handling.
A Trim Options for RHE25
A1 RHE25SSP, RHE25LP
Trim Assembly
4. Take center refractory and tilt so bottom edge slides
into support angle in back of fireplace.
RHE25SSP
5. Now press center refractory to back side of fireplace
and hold in place.
1. Install trim channels (left and right sides). Use two
screws to assemble each piece.
6. Take left or right refractory and align it so leading
edge faces outward. Place refractory in fireplace
side and slide it back to support center refractory.
2. Slide on the trim top channel and fasten it from the
back side.
3. Install the trim top deflector using two screws.
7. Install metallic piece in the leading edge (RHE32
only).
4. Remove ALL plastic protective covering from brass
trim.
8. Repeat Step 6 and 7 for remaining side refractory.
When side refractory is installed correctly,
the center refractory will be supported by
the side refractory.
Side View
9. Fasten top tab supports against refractory to hold
sides in place.
Trim Top
Deflector
Center
Right Side
Left Side
Leading
Edge
Leading
Trim Frame Top Section
FP1261a
Edge
Bottom Edge
Fig. 27 Trim top deflector.
FP1278
HE25LP
Fig. 26 Ceramic refractory.
1. To install the kit you do not have to remove any
piece of brass, you just add the external pieces.
Zero Clearance Kit
For installations other than in existing woodburning
fireplaces such as new construction or renovation
projects, a Zero Clearance Kit must be used. The
HEZC enables these inserts to be installed in combusti-
ble environments. It is recommended that an Air Kit
(AKZC) be installed whenever using a Zero Clearance
Kit. Consideration must be given to the dimensions of
2. Remove the frame trim from the unit if it is already
installed.
3. Install trim channels (left and right sides) by remov-
ing the two screws that hold the side brass trim and
put them back to hold both parts.
4. Slide on the trim top channel and fasten it from the
back side.
22
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
5. Remove the two screws that hold the top brass trim.
Trim Assembly
6. Install the two brackets to the studs in the bottom of
the top channel. Use the nuts supplied with top trim
channel.
1. Remove the front glass (see "Glass Frame Re-
moval" section).
2. Install top and bottom brass trim by using the short-
est black screw. (Fig. 28 & 29)
A flat louvre kit OR a bay window kit need
to be chosen to complete the installation.
3. Install bottom decorative plate by simply sliding it
under the unit floor. No fastening is required for this
installation. (Fig. 30) Be sure to remove protective
cover.
RHE25SSP & HE25LP Replacement Parts
5
4. Install the bottom louvre assembly by fastening the
hinges with four screws to the pre-punched holes in
the cabinet.
6
6
4
4
3
1
5. Re-install the front glass.
6. Install the top louvre by using the hooks to hang it in
place.
2
Trim Top
Screws
FP1289
Vermont Castings, Majestic Products reserves the right to make
changes in design, materials, specifications, prices and discontinue
colors and products at any time, without notice.
Glass Frame
IMPORTANT: Only trim panel assemblies approved
by Vermont Castings, Majestic Products can be
used on these products.
ALL repair parts will be available from your local dealer.
Trim Bottom
FP1290
When ordering, always give the following information:
Model and serial number, part description with finish
and part number.
Fig. 28 Install top and bottom brass trim.
Key Description
RHE25SSP
10001939
55099
55077
55096
-
HE25LP(1)
Louvre
1
2
3
4
5
6
7
Trim Frame Black
-
Trim Top Deflector
Trim Top Channel(1)
Trim Side Channel
Trim Top Channel
Trim Side Channel
-
NOTE: Position
brass trim top as
shown (small end up)
to prevent heat
discoloration.
-
-
55097
55080
-
Glass Frame
Fasteners Package
(Not Shown)
FP1291
54618
57633
Fig. 29 Position brass trim to with small end up.
(1) LP trim to be used with SSP trim.
SSP trim dimensions are for openings smaller than
26¹⁄₂" H x 38" W (673mm x 965mm).
LP trim dimensions are for openings smaller than 29" H
x 41" W (736mm x 1040mm).
A2 HE25FP Trim
For use with RHEDV25
Bottom
Decorative
Plate
HE25FP
Flat face louvres with polished window
brass trim
FP1292
Fig. 30 Slide bottom decorative plate under unit floor.
10000836
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
2. Install the hanging brackets. (Fig. 34)
HE25FP Replacement Parts
3. Install bracket on each side of the cabinet. Fig. 38)
4. Install the ceramic piece inside the bay window.
1
2
3
4
5. Install the bay window by hanging it onto the lower
tabs of the hanging brackets. (Fig. 35)
6. Install top louvre by engaging the oblong holes with
the upper tabs of the hanging brackets. (Fig. 36)
7. Install brass trim to the steel frame. (Fig. 37)
FP1293
5
Vermont Castings, Majestic Products reserves the right to make
changes in design, materials, specifications, prices and discontinue
colors and products at any time, without notice.
IMPORTANT: Only trim panel assemblies approved
by Vermont Castings, Majestic Products can be
used on these products.
Fan Control Box
KT205
ALL repair parts will be available from your local dealer.
Fig. 31 Remove fan control box.
When ordering, always give the following information:
Model and serial number, part description with finish
and part number.
Fan Control
Box
Key Description
HE25FP
55098
55079
54603
54604
52356
57916
1
2
3
4
5
6
Trim Window Top/Bottom
Extension
Bracket
Trim Bottom Channel
Top Louvre Assembly
Bottom Louvre Assembly
Hinge
KT207
Fasteners Package (Not Shown)
Fig. 32 Attach the control box to the bracket and install
bracket into the cabinet.
A3 HE25BTKP
For use with RHEDV25
HE25BTKP Bay window kit with polished brass trim
Do not remove existing glass with frame.
Extension
Knobs
Trim Assembly
KT204a
1. Reposition controls.
Fig. 33 Install the knob extensions. (RN/RP models Only)
a. Remove the Fan Speed Control Box. (Fig. 31)
b. Attach the Fan Speed Control Box to the Bracket
(Fig. 32) and install the Bracket into the Cabinet.
Hanging Bracket
Only for RN/RP VALVE units:
c. Install the Control Knob Extensions onto the
appropriate Control Valve Knobs. (Fig. 33)
On units fitted with a Honeywell brand control
valve the location of the control knobs and the
ignitor button may vary slightly from those
shown in Figure 33. The Honeywell exten-
sion pieces are visually different in design
and are not interchangeable with the RN/RP
knobs shown in Figure 33.
KT209b
Fig. 34 Hanging bracket alignment.
24
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
HE25BTKP Replacement Parts
1
11
HI
LO
2
15
16
KT210a
6
7
9
10
Fig. 35 Hang the window grille or the steel frame onto the
lower tabs of the hanging brackets.
5
3
4
13
12
8
KT211a
0801
Fig. 36 Engage the slots in the upper grille top louvre with
the upper tabs of the hanging brackets.
17
Vermont Castings, Majestic Products reserves the right to make
changes in design, materials, specifications, prices and discontinue
colors and products at any time, without notice.
IMPORTANT: Only trim panel assemblies approved
by Vermont Castings, Majestic Products can be
used on these products.
ALL repair parts will be available from your local dealer.
When ordering, always give the following information:
Model and serial number, part description with finish
and part number.
Key Description
HE25BTKP
1
Trim Window Top & Bottom
(w/magnets)
10000779
10000780
10000787
10000786
52356
KT212a
2
3
4
5
6
7
8
9
Top Louvre Assembly
Bottom Louvre Assembly
Control Door
Fig. 37 Attach magnets and brass trim to the steel frame.
Hinge
Glass Side
10000388
10000389
10000529
Glass Front
Ceramic Refractory Bay
Extension Knob On/Off
(only for RN/RP valves)
55163
10 Extension Knob Hi/Lo
(only for RN/RP valves)
55162
1409129
1409146
57877
11 Bracket Hanging Bay Window
12 Bracket Extension Rheostat
13 Bracket Mounting Bay Window
14 Hardware Package (Not Shown)
FP1270
Fig. 38 Bracket for HEBTKP.
10000530
15 Extension Knob Hi/Lo
(Honeywell Valve)
20000006
20000007
20001427
16 Extension Knob On/Off
(Honeywell Valve)
17 Extension Knob Piezo Ignitor
(Honeywell Valve)
10000836
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
3. Install the trim top deflector and use two (2) screws
A4 Riser Kits
to fasten it. (Fig. 40 & 41)
For use with RHEDV25 (Refer to Page 34, Figure 55)
1. Install the unit according to Homeowner’s Manual.
2. Install the trim according to Installation Instructions.
4. Remove ALL plastic protective covering from brass
trim.
Trim Top
Channel
3. Remove the two (2) screws at the bottom of the
trim.
4. Install the riser at the bottom of the trim. (Fig. 55)
5. Fasten the trim with the same two (2) screws
removed in Step 3.
Trim
Side
Trim
Channel
Side
Channel
Riser Trim Dimensions
Deflector
Trim Top
Length - A
Height - B
Depth - C
Screw
RHE25R1-Riser 1" 38.3" (973mm) 1" (25.6mm) 2.86" (72.8mm)
RHE25R-2Riser 2" 38.3" (973mm) 2" (50.9mm) 2.89" (73.6mm)
RHE25R5-Riser 5" 38.3" (973mm) 5" (127.9mm) 2.86" (72.8mm)
FP1260
Fig. 40 Install trim channels and trim top deflector.
B Trim Options for RHE32
Side View
B1 RHESS, RHESL, RHESSD, RHESLD, &
RHESXL Trims
For use with RHEDV32
Frame Assembly
Trim Top Deflector
RHESS, RHESL, RHESSD, RHESLD and RHESXL
1. Lay Trim Top Facing and Trim Side Facings, face
down on to an even surface such as a table or floor.
Be sure not to scratch the painted surfaces.
2. Install the nuts and bolts. (Fig. 39)
Trim Frame Top
Section
FP1261a
Fig. 41 Trim top deflector.
RHESSD and RHESLD (Fig. 42)
10/24 Screws
Frame Top
1. Install trim channels (left and right sides). Use two
(2) screws to assemble each piece.
2. Peel off plastic protective covering from top edges of
the inner sides where they will be covered by the
inner top trim facing.
3. Place the trim facing inner top in place (do not fasten
it yet). Peel off the plastic protective covering from
the bottom edge.
10/24 Nuts
Left
4. Install the trim top deflector and fasten it (will hold
the inner top piece). Use two (2) screws to assemble
them.
Right Frame
Frame
FP1259
5. Install trim channels (left and right sides). Use two
(2) screws to assemble each piece.
Fig. 39 Attache left and right frame to frame top.
6. Slide on the trim top channel and fasten it from the
back side.
Trim Assembly
RHESS, RHESL and RHESXL (Fig. 40)
7. Remove ALL plastic protective covering from brass
trim.
1. Install trim channels (left and right sides). Use two
(2) screws to assemble each piece.
2. Slide on the trim top channel and fasten it from the
back side.
26
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Trim Top
Channel
Trim
Side
Channel
Trim
Side
Channel
Screw
Trim
Framing Inner Sides
FP1262
Screws
Fig. 42 RHESSD and RHESLD trim assembly.
FP1263
Front View
A flat louvre kit OR a bay window kit need
Fig. 43 Frame mounting.
to be chosen to complete the installation.
Plastic on the trim must be removed
before mounting onto the fireplace.
Frame Mounting
General Information
Glass must be tightly pressed against the
front of the frame in order to prevent
screws from damaging glass edges.
The Decorative Front Frame should be installed last
after all other work, such as gas connections, venting,
etc., has been completed and thoroughly checked and
tested for operation, leaks and proper installation re-
quirements.
Fit decorative frame to the fireplace and fasten. (Fig. 43)
10000836
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
RHESS, RHESL, RHESSD, RHESLD, RHESXL Trim Replacement Parts
5
1
IMPORTANT: Only trim panel assemblies ap-
proved by Vermont Castings, Majestic Products
4
can be used on these products.
ALL repair parts will be available from your local
dealer.
6
2
3
6
When ordering, always give the following informa-
tion: Model and serial number, part description with
finish and part number.
7
9
8
FP1264
Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and
products at any time, without notice.
Key Description
RHESS(2)
RHESL(3)
RHESSD(3)
RHESLD(3)
RHESXL(4)
1
2
Trim Frame Top, Flat Black
57929
57927
57928
17634
50586
50589
-
57932
57930
57931
17634
50587
50590
-
57929
57927
57928
17634
17611
17623
17609
17620
17622
55043
57932
57930
57931
17634
17612
17624
17610
17619
17621
55043
57935
57933
57934
17634
52787
52788
-
Trim Frame Left, Flat Black
Trim Frame Right, Flat Black
Trim Top Deflector(1)
3
4
5
Trim Top Channel(1)
6
Trim Side Channel Left(1)
Trim Facing Inner Top(1)
Trim Facing Inner Left(1)
Trim Facing Inner Right(1)
Fasteners Package (Not Shown)
7
8
-
-
-
9
-
-
-
10
55043
55043
55043
(1)Specify Finish (Antique or Polished Brass)
(2)SS and SSD trim dimensions are for openings smaller than 26¹⁄₂"H x 38" W (673mm x 965mm)
(3)SL and SLD trim dimensions are for openings smaller than 29"H x 41" W (736mm x 1040mm)
(4)SXL trim dimensions are for openings smaller than 32"H x 43" W (813mm x 1092mm)
28
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
RHEBXL
B2 RHEBSL & RHEBXL Trims
To install the kit you do not have to remove any
piece of brass, just add the external pieces.
For use with RHEDV32
Remove the frame trim from the unit if it is already
installed.
Trim Assembly
RHEBSL
1. Install trim channels (left and right sides)by remov-
ing the two (2) screws that hold the side brass trim
and put them back to hold both parts.
1. Install trim channels (left and right sides). Use two
(2) screws to assemble each piece.
2. Slide on the trim top channel and fasten it from the
back side.
2. Slide on the trim top channel and fasten it from the
back side.
3. Install the trim top deflector. Use two (2) screws to
fasten it. (Fig. 44)
3. Remove the two (2) screws that hold the top brass
trim.
4. Remove ALL plastic protective covering from brass
trim.
4. Install the two (2) brackets to the studs in the bottom
of the top channel. Use the nuts supplied with the
kit.
Side View
5. Reinstall the two (2) screws to hold the top trim
channel.
Trim Top Deflector
Trim Frame Top
Section
FP1261a
Fig. 44 Trim top deflector.
RHEBSLP, RHEBSLA, RHEBXLP, RHEBXLA Trim Replacement Parts
IMPORTANT: Only Trim Panel Assemblies Approved by
Vermont Castings, Majestic Products Can Be Used on
These Products.
5
3
ALL repair parts will be available from your local dealer.
When ordering, always give the following information:
Model and serial number, part description with finish and
part number;
1
2
4
(1) RHEBXLP or RHEBXLA to be used with RHEBSLP
or RHEBSLA trims.
6
4
6
(2) SL trim dimensions are for openings smaller than
27¹⁄₂"H x 40¹⁄₂" W (700mm x 1030mm)
(4) XL trim dimensions are for openings smaller than
30"H x 45⁵⁄₈" W (765mm x 1160mm)
Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and
products at any time, without notice.
Key Description
RHEBSLP
57926
17634-PB
57864
57862
-
RHEBSLA
57926
17634-AB
57844
57843
-
RHEBXLP(1)
RHEBXLA(1)
1
2
3
4
5
6
7
Trim Frame Flat Black
-
-
Trim Top Deflector
-
-
Trim Top Channel
-
-
Trim Side Channel
-
-
Trim Outer Top Channel
Trim Outer Side Channel
Fasteners Package (Not Shown)
57861
57863
57633
57845
57846
57633
-
-
54618
54618
10000836
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
B3 RHEFA and RHEFP Trims
For use with RHEDV32
Trim Assembly
1. Remove the front glass (Refer to "Glass Frame
Removal" section).
2. Install support window trim channel, top and bottom
brass trim by using the shortest black screw. (Fig. 45
& 46)
Bottom
Decorative
Plate
3. Install bottom decorative plate by simply sliding it
under the unit floor. No fastening is required for this
installation. (Fig. 47) Be sure to remove protective
cover.
FP1292
Fig. 47 Slide bottom decorative plate under unit floor.
RHEFA & RHEFP Trim Replacement Parts
4. Install the bottom louvre assembly by fastening the
hinges with four (4) screws to the pre-punched holes
in the cabinet.
1
2
3
5. Re-install the front glass.
6. Install the top louvre by using the hooks to hang it in
place.
4
Trim Top
Screws
5
6
FP1296
Vermont Castings, Majestic Products reserves the right to make
changes in design, materials, specifications, prices and discontinue
colors and products at any time, without notice.
Glass Frame
IMPORTANT: Only trim panel assemblies approved
by Vermont Castings, Majestic Products can be
used on these products.
Trim Bottom
ALL repair parts will be available from your local dealer.
FP1295
When ordering, always give the following information:
Model and serial number, part description with finish
and part number.
Fig. 45 Install support window trim channel and top and
bottom brass trim.
Key Description
RHEFA
RHEFP
1
Trim Window
Top/Bottom
52624-AB
52624-PB
Louvre
2
Plate Decorative
Bottom
NOTE: Position
brass trim top as
shown (small end up)
to prevent heat
discoloration.
17597-AB
57905
17597-PB
57905
3
4
Top Louvre Assembly
Bottom Louvre
Assembly
57906
57906
Glass Frame
5
Support Window
Trim Channel
57909
52356
57909
52356
FP1291
6
7
Hinge
Fig. 46 Position brass trim to with small end up.
Fasteners Package
(Not Shown)
57916
57916
30
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
B4 HEBTKP, HESBTKP, HECBTK, HECBTKMB & HEBTA Trims
For use with RHEDV32
HECBTK
Cast bay window and grilles in classic black trim kit
HECBKMB Cast bay window and grilles in midnight black porcelain enamel trim kit
HESBTKP Steel bay window with polished brass and cast grilles in classic black trim kit
HEBTKP
Steel bay window and bay louvres with polished brass trim kit
Install the bay window after all other installation work has been completed, thoroughly checked and tested for opera-
tion, leaks and proper installation requirements.
Do not remove existing glass with frame
HEBTKP
HESBTKP
HECBTK &
HECBTKMB
Fig. 48 Optional bay front windows available for use on the RHEDV32.
2. Install the hanging brackets. (Fig. 52)
HECBTKP, HECBTKMB and HESBTKP
Trim Assembly
3. Install the two (2) ceramic pieces inside the bay
window. (Fig. 48)
1. Reposition controls.
4. Install the bay window by hanging it onto the lower
tabs of the hanging brackets. (Fig. 53)
a. Remove the Fan Speed Control Box (Fig. 49)
b. Attach the Fan Speed Control Box to the Bracket
(Fig. 50) and install the Bracket into the Cabinet.
Only for RN/RP VALVE units:
5. Install the upper grille by engaging the oblong holes
with the upper tabs of the hanging brackets. (Fig.
54)
c. Install the Control Knob Extensions onto the
appropriate Control Valve Knobs (Fig. 51)
6. Install brass trim to the steel frame. (Fig. 55) (Only
for HESBTKP trim).
On units fitted with a Honeywell brand control
valve the location of the control knobs and the
ignitor button may vary slightly from those
shown in Figure 51. The Honeywell exten-
sion pieces are visually different in design
and are not interchangeable with the RN/RP
knobs shown in Figure 51.
HEBTKP Trim Assembly
1. Reposition controls.
a. Remove the Fan Speed Control Box (Fig. 49)
b. Attach the Fan Speed Control Box to the Bracket
(Fig. 50) and install the Bracket into the Cabinet.
Only for RN/RP VALVE units:
c. Install the Control Knob Extensions onto the
appropriate Control Valve Knobs. (Fig. 51)
10000836
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
On units fitted with a Honeywell brand control
Hanging Bracket
valve the location of the control knobs and
the ignitor button may vary slightly from those
shown in Figure 51. The Honeywell extension
pieces are visually different in design and are
not interchangeable with the RN/RP knobs
shown in Figure 51.
2. Install the hanging brackets. (Fig. 52)
3. Install bracket on each side of the cabinet. (Fig. 56)
4. Install the two ceramic pieces inside the bay win-
dow. (Fig. 48)
5. Install the bay window by hanging it onto the lower
tabs of the hanging brackets. (Fig. 51)
KT209a
Fig. 52 Hanging bracket alignment.
6. Install top louvre by engaging the oblong holes with
the upper tabs of the hanging brackets. (Fig. 54)
7. Install brass trim to the steel frame. (Fig. 55)
KT210
Fig. 53 Hang the window grille or the steel frame onto the
lower tabs of the hanging brackets.
Fan Control Box
KT205
Fig. 49 Remove fan control box.
KT211
Fan Control
Box
Fig. 54 Engage the slots in the upper grille top louvre with
the upper tabs of the hanging bracket.
Extension
Bracket
KT207
Fig. 50 Attach the control box to the bracket and install
bracket into the cabinet.
KT212a
Fig. 55 Attach magnets and brass trim to the steel frame.
Extension
Knobs
KT204a
Fig. 51 Install the knob extensions. (RN/RP models Only)
FP1270
Fig. 56 Bracket for HEBTKP.
32
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
HECBTK, HECBTKMB, HESBTKP, HEBTKP, HEBTA Trim Parts Replacement
1
3
14
3
13
6
9
7
10
5
8
4
6
2
5
7
20
16
18
11
12
15
HI
LO
19
0801
Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and
products at any time, without notice.
IMPORTANT: Only Trim Panel Assemblies Approved by Vermont Castings, Majestic Products Can Be Used on These Products.
ALL repair parts will be available from your local dealer.
When ordering, always give the following information: Model and serial number, part description with finish and part number;
Key Description
HECBTK
-
HECBTKMB
-
HESBTKP
55188-PB
-
HEBTKP
55188-PB
52828-PB
57945
HEBTA
1
2
Trim Window Top/Bottom w/magnets
55188-AB
Plate Decorative Bottom
Top Louvre (Grill) Assembly
Bottom Louvre (Grill) Assembly
Control Door
-
-
52828-AB
3
1301199
-
1341199
-
1301199
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4
57947
5
1301200
1301219
1301218
1301198
1601971
1601957
55163
55162
57772
1409129
1409146
-
1341200
1341219
1341218
1341198
1601971
1601957
55163
55162
57772
1409129
1409146
-
1301200
1301219
1301218
1409127
1601971
1601957
55163
57946
6
Bottom Louvre Left
-
7
Bottom Louvre Right
-
8
Bay Window Frame
1409127
1601971
1601957
55163
9
Glass Side
10
11
12
13
14
15
16
17
18
Glass Front
Extension Knob ON/OFF (RN/RP)
Extension Knob Hi/Lo (RN/RP)
Ceramic Refractory Bay (Set)
Bracket Hanging Bay Window
Bracket Extension Rheostat
Bracket Mounting Bay Window
Hardware Pkg. (Not Shown)
55162
55162
57772
57772
1409129
1409146
-
1409129
1409146
57877
10000108
10000108
10000108
10000108
-
-
-
Extension Knob Hi/Lo
(Honeywell Valve)
20000006
20000007
20000006
20000007
20000006
20000007
20000006
20000007
19
20
21
Extension Knob On/Off
(Honeywell Valve)
Extension Knob Piezo Ignitor
(Honeywell Valve)
20001427
-
20001427
-
20001427
-
20001427
52356
Hinge
-
10000836
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
Riser Trim Dimensions
B5 Cast Trim Options
Length A
Height B
Depth C
Cast Surround and Flat Face
HECBL Cast Surround Black
HECBLUE Cast Surround Blue
RHER1-Riser 1" 42" (1067mm) 1" (25.6mm) 2.55" (64.8mm)
RHER2-Riser 2" 42" (1067mm) 2" (50.9mm) 2.58" (65.6mm)
RHER5-Riser 5" 42" (1067mm) 5" (127.9mm) 2.58" (65.6mm)
HECCG
HECGR
CSSP
Cast Surround Charcoal Grey
Cast Surround Green
B8 Arch Door Kits
Polished Brass Small Trim for
Cast Surround
HEADKA
HEADKP
Antique Brass Arch Door
Polished Brass Arch Door
CSLP
Polished Brass Large Trim for Cast
Surround (to be used with CSSP)
C Trim Options for RHE42
C1 RHE42SSP and RHE42LP Trims
For use with RHEDV42
B6 Freestanding Kits
Convert Insert Into A Freestanding Stove
NOTE: 1. Requires Bay Window Face Kit
RHE42SSP Small surround, black with thin polished
2. Vent starter kit FSHEDVSK must be in
stalledtouseanyofthefreestandingshells.
brass edge
RHE42LP Large polished brass edge (to be used
FSNVCSKB Classic Black Freestanding Cast Shell
with RHE42SSP)
FSNVCSKM Midnight Black Enamel Freestanding
Cast Shell
Trim Assembly
RHE42SSP
FSNVCSKG Green Enamel Freestanding Cast Shell
1. Install trim channels (left and right sides). Use two
(2) screws to assemble each piece.
B7 Riser Kits
1. Install the unit according to Homeowner’s Manual.
2. Install the trim according to Installation Instructions.
2. Slide on the trim top channel and fasten it from the
back side.
3. Install the trim top deflector. Use two (2) screws to
fasten it. (Fig. 58)
3. Remove the two (2) screws at the bottom of the
trim.
4. Remove ALL plastic protective covering from brass
trim.
4. Install the riser at the bottom of the trim. (Fig. 57)
5. Fasten the trim with the same two (2) screws
removed in Step 3.
Side View
NOTE: The riser kit should only be used with the
RHEBSL & RHEBXL trim.
Trim Kit
Trim Top Deflector
Trim Frame Top
Section
FP1261a
Fig. 58 Trim top deflector.
RHE42LP
Riser
Decorative
Trim
To install the kit you do not have to remove any piece
of brass, you just add the external pieces.
Remove the frame trim from the unit if it is already
installed.
A
B
C
FP1276
Fig. 57 RHEBSL, RHEBXL trim kit.
34
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
1. Install trim channels (left and right sides) by remov-
C2 RHE42FP Trim
ing the two (2) screws that hold the side brass trim
and put them back to hold both parts.
For use with RHEDV42
2. Slide on the trim top channel and fasten it from the
back side.
RHE42FP Flat face louvres with polished window
brass trim
3. Remove the two (2) screws that hold the top brass
trim.
Trim Assembly
4. Install the two (2) brackets to the studs in the bottom
of the top channel. Use the nuts supplied with the kit.
1. Remove the front glass (Refer to "Glass Frame
Removal" section).
5. Reinstall the two (2) screws to hold the top trim
channel.
2. Install top and bottom brass trim (Fig. 59 & Fig. 60)
Use the shortest black screw.
A flat louvre kit OR a bay window kit
need to be chosen to complete the
installation.
4. Install bottom decorative plate by simply sliding it
under the unit. No fastening is required for this
installation. (Fig. 61) Be sure to remove the protec-
tive plastic cover from the trim.
RHE42SSP & RHE42LP Replacement Parts
5. Install the bottom louvre assembly by fastening the
hinges with four (4) screws to the pre-punched holes
in the cabinet.
4
3
5
5
3
2
6. Re-install the front glass.
7. Install the top louvre assembly by using the hooks to
hang it in place.
1
7
Trim Top
Screws
FP1297
Vermont Castings, Majestic Products reserves the right to make
changes in design, materials, specifications, prices and discontinue
colors and products at any time, without notice.
Glass Frame
IMPORTANT: Only Trim Panel Assemblies Approved by
Vermont Castings, Majestic Products Can Be Used on These
Products.
Trim Bottom
ALL repair parts will be available from your local dealer.
FP1295
When ordering, always give the following information: Model
and serial number, part description with finish and part
number;
Fig. 59 Install support window trim channel and top and
bottom brass trim.
Key Description
RHE42SSP
RHE42LP(1)
1
Frame Trim Kit
(Metallic Black)
10000931
-
Louvre
2
3
4
5
6
Trim Top Channel
Trim Side Channel
Trim Top Channel
Trim Side Channel
57508
-
NOTE: Position
brass trim top as
shown (small end up)
to prevent heat
discoloration.
57509
-
-
-
57511
57507
Fasteners Package
(Not Shown)
Glass Frame
54618
-
-
7
Trim Top Deflector
10000912
FP1291
Fig. 60 Position brass trim to with small end up.
(1)LP trim to be used with SSP trim.
SSP trim dimensions are for openings smaller than
30³⁄₄" H x 42⁷⁄₈"W (781mm x 1089mm)
LP trim dimensions are for openings smaller than
33³⁄₁₆"H x 48"W (846mm x 1225mm)
10000836
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
C3 RHE42BTKP
For use with RHEDV42
RHE42BTKP Bay window with polished brass trim
Do not remove existing glass with frame.
Bottom
Decorative
Plate
Trim Assembly
1. Reposition controls.
FP1292
a. Remove the Fan Speed Control Box. (Fig. 62)
Fig. 61 Slide bottom decorative plate under unit floor.
b. Attach the Fan Speed Control Box to the Bracket
(Fig. 61) and install the Bracket into the Cabinet.
RHE42FP Replacement Parts
Only for RN/RP VALVE units:
c. Install the Control Knob Extensions onto the
appropriate Control Valve Knobs. (Fig. 64)
1
2
3
On units fitted with a Honeywell brand control
valve the location of the control knobs and the
ignitor button may vary slightly from those
shown in Figure 64. The Honeywell extension
pieces are visually different in design and are
not interchangeable with the RN/RP knobs
shown in Figure 64.
4
5
6
FP1296
Vermont Castings, Majestic Products reserves the right to make
changes in design, materials, specifications, prices and discontinue
colors and products at any time, without notice.
2. Install the hanging brackets. (Fig. 65)
3. Install the two (2) ceramic pieces inside the bay
window.
IMPORTANT: Only trim panel assemblies approved
by Vermont Castings, Majestic Products can be
used on these products.
4. Install the bay window by hanging it onto the lower
tabs of the hanging brackets. (Fig. 66)
5. Install top louvre by engaging the oblong holes with
the upper tabs of the hanging brackets. (Fig. 67)
ALL repair parts will be available from your local dealer.
When ordering, always give the following information:
Model and serial number, part description with finish
and part number.
6. Install brass trim to the steel frame. (Fig. 68)
Key Description
RHE42FP
10000880
10000915
10000929
1
2
3
Trim Window Top/Bottom
Plate Decorative Bottom
Top Louvre Assembly (Metallic Black)
Fan Control Box
4
Bottom Louvre Assembly
(Metallic Black)
KT205
10000930
52356
Fig. 62 Remove fan control box.
5
6
Hinge
Hardware Package (Not Shown)
57916
Fan Control
Box
Extension
Bracket
KT207
Fig. 63 Attach the control box to the bracket and install
bracket into the cabinet.
36
10000836
Download from Www.Somanuals.com. All Manuals Search And Download.
Vermont Castings, Majestic Products RHE Natural Vent Insert
HE42BTKP Trim Replacement Parts
1
12
HI
LO
2
14
Extension
Knobs
15
KT204a
11
6
8
7
10
Fig. 64 Install the knob extensions. (RN/RP models Only)
Hanging Bracket
3
9
4
13
5
16
Vermont Castings, Majestic Products reserves the right to make
changes in design, materials, specifications, prices and discontinue
colors and products at any time, without notice.
KT209a
Fig. 65 Hanging bracket alignment.
IMPORTANT: Only trim panel assemblies approved
by Vermont Castings, Majestic Products can be
used on these products.
ALL repair parts will be available from your local dealer.
When ordering, always give the following information:
Model and serial number, part description with finish
and part number.
KT210
Fig. 66 Hang the window grille or the steel frame onto the
Key Description
HE42BTKP
lower tabs of the hanging brackets.
1
Trim Window Top & Bottom
(w/magnets)
57576
2
3
Top Louvre Assembly (Metallic Black)
10000932
Bottom Louvre Assembly
(Metallic Black)
10000933
10000934
57551
4
5
Control Door (Metallic Black)
Plate Decorative Bottom
Hinge
KT211a
6
52356
Fig. 67 Engage the slots in the upper grille top louvre with
the upper tabs of the hanging brackets.
7
Glass Side
57405
8
Glass Front
57406
9
Ceramic Refractory Bay
10000854
10
Extension Knob On/Off
(only for RN/RP valves)
55163
11
Extension Knob Hi/Lo
(only for RN/RP valves)
55162
12
13
14
Bracket Hanging Bay Window
Bracket Extension Rheostat
1409129
1409146
Extension Knob Hi/Lo
(Honeywell Valve)
20000006
20000007
15
16
17
Extension Knob On/Off
(Honeywell Valve)
Extension Knob Piezo Ignitor
(Honeywell Valve)
KT212a
20001427
10000928
Hardware Package (Not Shown)
Fig. 68 Attach magnets and brass trim to the steel frame.
10000836
37
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED LIFETIME WARRANTY
PRODUCT COVERED BY THIS WARRANTY
All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces
equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
BASIC WARRANTY
•
Any part and/or component replaced under the provisions of this
warranty is covered for six months or the remainder of the original
warranty, whichever is longest.
The Vermont Castings, Majestic Products Company (hereinafter
referred to collectively as the Company) warrants that your new
Vermont Castings or Majestic Gas Fireplace/Stove is free from
manufacturing and material defects for a period of one year from the
date of purchase, subject to the following conditions and limitations.
•
This warranty is limited to the repair of or replacement of part(s) found
to be defective in material or workmanship, provided that such part(s)
have been subjected to normal conditions of use and service, after
said defect is confirmed by the Company’s inspection.
EXTENDED LIFETIME WARRANTY
•
•
Thecompanymay, at itsdiscretion, fullydischargeallobligationswith
respect to this warranty by refunding the wholesale price of the
defective part(s)
The heat exchanger, where applicable, and combustion chamber of
every Vermont Castings or Majestic gas product is warranted for life
against through wall perforation. All appliances equipped with an
Insta-Flame Ceramic Burner have limited lifetime coverage on the
ceramic burner plaque. Warrantees are made to the original owner
subject to proof of purchase and the conditions and limitations listed
on this Warranty Document
Any installation, labor, construction, transportation, or other related
costs/expensesarisingfromdefectivepart(s), repair, replacement, or
otherwise of same, will not be covered by this warranty, nor shall the
Company assume responsibility for same. Further, the Company will
not be responsible for any incidental, indirect, or consequential
damages except as provided by law.
COMPONENT WARRANTY
CAST IRON: All external and internal cast iron parts are warranted for a
period of three years.
•
SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR
LIMITATIONSOFINCIDENTALANDCONSEQUENTIALDAMAGES
ORLIMITATIONSONHOWLONGANIMPLIEDWARRANTYLASTS,
SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR
CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY
FROM STATE TO STATE.
Note: On porcelain enamel finished external parts and accessories
The Company offers no Warranty on chipping of enamel surfaces.
Inspect all product prior to accepting it for any damage to the enamel.
The salt air environment of coastal areas or a high humidity
environment can be corrosive to the porcelain enamel finish. These
conditions can cause rusting of the cast iron beneath the porcelain
enamel finish, which will cause the finish to flake off.
•
•
•
•
Allotherwarranties-expressedorimplied-withrespecttotheproduct,
its components and accessories, or any obligations/liabilities on the
part of the Company are hereby expressly excluded.
Dye lot variations with replacement parts and/or accessories can
occur and are not covered by warranty.
The Company neither assumes, nor authorizes any third party to
assume on its behalf, any other liabilities with respect to the sale of
this Vermont Castings, Majestic product
GLASS DOORS: Glass doors are covered for a period of one year.
Glass doors are not warranted for breakage due to misuse or
accident. Glass doors are not covered for discoloration or burned in
stains due to environmental issues, or improper cleaning and
maintenance.
The warranties as outlined within this document do not apply to
chimney components or other non Vermont Castings, Majestic
accessories used in conjunction with the installation of this product..
Damage to the unit while in transit is not covered by this warranty but
is subject to claim against the common carrier. Contact the dealer
from whom you purchased your fireplace/stove (do not operate the
appliance as this might negate the ability to process the claim with the
carrier).
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be
cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar
mix and masonry cleaners may corrode the brass finish. The
Company will not be responsible for, nor will it warrant any brass parts
which are damaged by external chemicals or down draft conditions.
•
•
The Company will not be responsible for:
GAS VALVES: Gas valves are covered for a period of one year
a) Down drafts or spillage caused by environmental conditions such
as near-by trees, buildings, roof tops, hills, or mountains.
b) Inadequate ventilation or negative air pressure caused by
mechanical systems such as furnaces, fans, clothes dryers, etc.
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and
mechanical components of the burner assembly are covered for one
year. All steel tube burners are warranted for one year.
ACCESSORIES: Unless otherwise noted all components and Vermont
Castings, Majestic Products company supplied accessories are covered
for a period of one year.
This warranty is void if:
a) The fireplace has been operated in atmospheres contaminated
by chlorine, fluorine, or other damaging chemicals.
b) The fireplace has been subjected to prolonged periods of
dampness or condensation
c) Any damages to the fireplace, combustion chamber, heat
exchangerorothercomponentsduetowater,orweatherdamage,
which is the result of but not limited to, improper chimney/venting
installation.
CONDITIONS AND LIMITATIONS
•
This new Vermont Castings or Majestic product must be installed by
a competent, authorized, service contractor. A licensed technician,
as prescribed by the local jurisdiction must perform any installation/
service work. It must be installed and operated at all times in
accordance with the Installation and Operating instructions furnished
with the product. Any alteration, willful abuse, accident, or misuse of
the product shall nullify this warranty.
d) Any alteration, willful abuse, accident, or misuse of the product
has occurred.
•
•
This warranty is non-transferable, and is made to the original owner,
provided that the purchase was made through an authorized supplier
of the Company.
IF WARRANTY SERVICE IS NEEDED…
1) Contactyoursupplier. Makesureyouhaveyourwarranty,
your sales receipt, and the model/serial number of your
Vermont Castings, Majestic product.
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK
YOURSELF.
ThecustomermustpayforanyAuthorizedDealerin-hometravelfees
or service charges for in-home repair work. It is the dealers option
whether the repair work will be done in the customer’s home or in the
dealer’s shop.
•
If upon inspection, the damage is found to be the fault of the
manufacturer, repairs will be authorized at no charge to the customer
parts and/or labor.
38
10000836