VEC018-AC
TM
MANUFACTURING, Lt.d
P O CKET G ENERATO R™
P O RTABLE/ CO RDLESS/ RECHARG EABLE
P OW ER SUP P LY
110 -VO LT AC & 12 -VO LT DC
PATENT PENDING
OWNER’S MANUAL
& WARRANTY INFORMATION
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARD-
ING SAFETY, OPERATION,
MAINTENANCE AND STORAGE OF THIS PRODUCT.
PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE
3003 Greene St., Hollywood, FL 33020
Tel: (954) 923-1155 • Fax: (954) 923-8111
Download from Www.Somanuals.com. All Manuals Search And Download.
Pocket Generator™ Portable/ Cordless/ Rechargeable
Power Supply
SYSTEM FEATURES
• Take your home or office appliances and electronics with you - portable source
of 12-volt DC power or 110-volt AC power - ideal for use anywhere that
110-volt utility power is unavailable or inconvenient.
• Includes Vector™ Power Force 50™ inverter.
• Powers or charges portable appliances, tools, and electronic devices - cell
phones, camcorders, laptop computers, lamps, fans, radios, TV/ VCRs, CD players,
worklights, etc. (12-volt DC or 110-volt AC).
• Easy recharging from vehicle, boat or RV 12-volt DC accessory outlet, or
110-volt AC household wall socket (AC and DC charging adapters included).
• Equipped with in-line 10-amp fuse to protect the unit and any devices it is
powering or recharging.
• Compact, sturdy, lightweight design.
• Water-resistant, padded case - with belt holster and removable shoulder strap.
• Built-in 12-volt plug-in receptacle (cigarette lighter-type).
• Easy-to-use emergency power supply to boost low battery system in vehicle, RV,
boat (note: will not recharge a completely dead vehicle battery).
• Use as a Memory Saver - protects pre-set electronic settings for seats, radio,
A/ C, etc., if battery power is to be disconnected for repair/ maintenance.
• High surge capacity: 50-watt continuous power - 80-watt peak.
• Low power consumption ensures longer battery life.
• Built-in, single 110-volt AC receptacle.
• Electronic circuit protection prevents damage due to overload/ insufficient ventilation.
• Low-battery shutdown automatically occurs when battery discharges to 10.6-volts,
preventing battery damage.
• Includes 5 amp hour 12-volt sealed lead acid battery system.
CAUTIO NS:
1. Completely charge the Pocket Generator™ before using it for the first time.
2. The AC and DC chargers provided with this unit should never be used with any
other device - they are designed specifically for use with the Pocket Generator™.
3. Never attempt to recharge the Pocket Generator™ using any recharger other
than the ones supplied.
4. Always use the Pocket Generator™ on a stable, flat surface and be sure that
there is adequate ventilation.
5. Do not use the Pocket Generator™ near flammable materials or in locations
that may accumulate flammable fumes or gases.
Continued on next page...
2
Download from Www.Somanuals.com. All Manuals Search And Download.
6. WARNING : Do not run both AC and DC devices at the same time.
7. ALWAYS turn OFF the Power Force 50™ inverter BEFORE charging the
Pocket Generator™.
8. The nylon case that is provided with the Pocket Generator™ is water-resistant
only to the extent that it will help protect the unit from rain or water spray; never
immerse the unit in water (fresh or salt).
9. Do not expose the Pocket Generator™ to extreme heat or flames.
10. Do not exceed recommended charging times.
11. Continuous run times are limited, see charts for estimated operation times.
RECHARGING THE Pocket Generator™
CAUTION:
• IMPORTANT: Before recharging from an AC power source, verify that the source
is 110-volts only. Do not plug this unit’s 110-volt charger into a 220-volt
power source.
• IMPORTANT: Be sure that power inverter ON/ OFF switch is in OFF position
before recharging.
Recharging From A110-volt AC Power Source
1. Before initial use, it will take 18-20 hours to fully charge the Pocket Generator™.
Subsequent charges will only take 12-15 hours (approx.).
2. Insert the cigarette lighter plug at the end of the AC charger cord into the
matching 12-volt receptacle on the side of the Pocket Generator™.
3. Plug the charger into any standard 110/ 120-volt AC electrical outlet. Never
plug a 110-volt charger into a 220-volt power source.
Recharging From A12-volt DC Power Source
CAUTIO N:
Do not connect the Pocket Generator™ DC charger to a car or boat electrical
system (12-volt DC negative-ground only) without first starting the engine. Failure to
do so could damage the vehicle’s battery.
1. Insert the cigarette lighter plug at one end of the DC charger cord into the
matching 12-volt receptacle on the side of the Pocket Generator™.
2. Insert the cigarette lighter plug at the other end of the cord into the vehicle’s
cigarette lighter receptacle. Rotate the plug slightly to ensure good contact. A
green L.E.D. light on the cigarette plug will indicate a proper connection.
3. The Pocket Generator™ should be charged initially for 4-6 hours, while driving,
before use. Subsequent charges should only require 2-4hours (approx.).
4. The DC charging system will not provide as full a charge as is obtained with a
110-volt charging system.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: Vector™ recommends charging from a vehicle only while its engine is
running, so as not to run down the vehicle’s battery. The ideal charging
rate is 14.5-15.5 volts, which is nearly identical to the charging rate of
most vehicle batteries.
OPERATION
Estimated run-times.
12-VOLT DC APPLIANCE
APPROX. RUNNING TIME
CELL PHONE,
FLORESCENT LIGHT
6-12 HOURS
5 HOURS
RADIO, FAN, DEPTH FINDER
CAMCORDER, VCR, SPOTLIGHT
ELECTRIC TOOLS, BILGE PUMP
INFLATOR/ RAFT
2.5 HOURS
1 HOUR
50 MINUTES
25 MINUTES
AIR COMPRESSOR
110-VOLT AC APPLIANCE
50 WATT LAMP
APPROX. RUNNING TIME
40 MINUTES
LAPTOP / PRINTER
DESK FAN
1.5 HOURS
2.0 HOURS
STEREO/ CD PLAYER
2.5 HOURS
CELLULAR PHONE, POW ER TOOLS
& CAMCORDER CHARGERS
5 TO 10 HOURS
4
Download from Www.Somanuals.com. All Manuals Search And Download.
110-volt AC Operation
CAUTION: Rechargeable Devices
Certain rechargeable devices are designed to be recharged by plugging them
directly into an AC receptacle. These devices may damage the inverter unit of the
Pocket Generator™. When first using a rechargeable device, monitor its temperature
for the initial ten minutes of use to determine whether it emits excessive heat. If
excessive heat is detected, it is a good indication that the device should not be
used with this unit. This problem does not occur with the majority of battery-operated
equipment. Most of these devices use a separate charger or transformer that is
plugged into an AC receptacle. The Pocket Generator™ is capable of running
most chargers and transformers.
1. Make sure that the ON/ OFF switch on the inverter is in the OFF position.
2. Insert the 110-volt AC plug on the device to be operated into the AC outlet on
the power inverter.
3. Turn the power inverter’s ON/ OFF switch to ON.
4. Switch on the device, and operate as usual. Run-time depends upon the amperage
draw of the device (see charts).
5. Green power/ ON light next to switch will be lit.
12-volt DC Operation
WARNING S
• W hen using the Pocket Generator™ Rechargeable Power Supply to run
12-volt devices, always check the polarity of the device to verify that it is negative
ground. The Pocket Generator’s™ DC receptacle has an output limit of
10 amps; do not use it to power devices that require more than 10 amps.
Note: The unit has an in-line 10-amp fuse that is designed to fail in the event the
unit is used with any device requiring more than 10 amps.
• Always turn the power inverter switch to OFF position while running any 12-volt
device, boosting vehicle battery system, using as Memory Saver, or recharging
the Pocket Generator™ from either 110-volt AC or 12-volt DC power source.
Failure to do so will void manufacturer’s warranty.
1. Simply insert the device’s 12-volt plug into the DC receptacle on the side of the
Pocket Generator™.
2. Switch on the device, and operate as usual. Run-time depends upon the
amperage draw of the device.
3. W hen necessary, recharge the Pocket Generator™, as directed in this manual.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
To Use The Pocket Generator™ To Boost Vehicle’s
Low Battery System
WARNING : Be sure that the ON/ OFF switch on the inverter is in the OFF
position, before using unit as Battery Booster. Failure to do so may cause damage
to the inverter, and will void manufacturer’s warranty. Note: The Pocket Generator™
will not fully charge a completely dead battery, but it can be used to boost a
vehicle’s weak battery system, or to provide auxiliary power for the onboard
electrical systems and selected memory settings for electronics (A/ C, seats, radio,
etc.). Using the adapter cord with two cigarette lighter-type plugs, insert one end
of the cord into the vehicle’s cigarette lighter receptacle, and the other end into the
corresponding receptacle on the Pocket Generator™. W hen power assist is
completed, disconnect the adapter cord’s plugs from the vehicle’s cigarette lighter
receptacle and the Pocket Generator™.
To Use The Pocket Generator™ As A Memory Saver For
Onboard Systems And Pre-Sets
WARNING : Be sure that the ON/ OFF switch on the inverter is in the OFF
position, before using unit as Memory Saver. Failure to do so may cause damage
to the inverter, and will void manufacturer’s warranty. W hen the vehicle’s battery
system is to be disconnected for repair or maintenance, the Pocket Generator™
will provide auxiliary power to maintain the selected memory settings and other
onboard electrical systems, until power is restored. BEFORE the vehicle’s battery
system is disconnected: using the adapter cord with two cigarette lighter-type plugs,
insert one end of the cord into the vehicle’s cigarette lighter receptacle, and the
other end into the corresponding receptacle on the Pocket Generator™. Onboard
power will be maintained. AFTER the vehicle’s battery system is reconnected,
disconnect the adapter cord’s plugs from the vehicle’s cigarette lighter receptacle
and the Pocket Generator™.
Fuse Replacement
Main Fuse
1
2
1. Open the top flap of the Pocket Generator™,
carrying case. The main fuse holder’s
screw-on/ off cap will immediately be visible.
3
4
2. Unscrew the fuse holder cap and remove the fuse.
3. Replace with a new 10-amp fuse, if needed.
4. Screw fuse holder cap back on.
5. Close case securely.
Fig. B.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Storage
• Ideal storage temperature range is 50-68°F (10-20°C).
• Store the Pocket Generator™ in a cool, dry place with adequate ventilation for
all-around air circulation.
• Avoid locations that are exposed to heating units, radiators, direct sunlight, or
excessive humidity or dampness.
• To maximize useful life, fully charge the unit before storing.
• If storing at less than 50°F, recharge every six months; at 50-80°F, recharge
every three months; at 80-104°F, recharge every 45 days.
• Always make sure the unit is disconnected from charger before storing.
SPECIFICATIONS: Pocket Generator™
AC Output
DC Output
Fuse
110-volts
12-volts
10 amps
Battery
12-volt 5 amp hour sealed lead acid, maintenance-free
Inverter
Weight:
Height:
Depth:
50-watts continuous/ 80 amps peak surge capacity
4.60lbs.
6.25”
4.00”
7.50”
W idth:
Power Force 50™ Inverter
WARNING : Do not attempt to remove the inverter from the unit for any
reason - it is hard-wired into the unit, and you may cause unnecessary damage to
the unit and void the manufacturer’s warranty. In the event of any failure, refer to
the warranty information at the back of this manual and return the complete unit for
repair or replacement, or call the customer service department at Vector
Manufacturing, Ltd. (954) 923-1155.
The Vector™ Power Force 50™ inverter supplied with the Pocket Generator™ is
one in a series of the most advanced DC to AC inverters available today. W ith
proper care and maintenance, it will deliver years of dependable service. For easy
reference, see sections titled:
Introduction
How the Power Force 50™ Inverter Works
Power Source Requirements
Fuse Replacement
Operating Tips
Troubleshooting
Specifications
7
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
The Power Force 50™ supplies 50-watts of continuous power, with an 80-watt
peak, via a household-type outlet that is ready to deliver 110-volt AC power
whenever and wherever it is needed. Simply, fully charge before use and turn ON
the power switch to operate small electronic devices such as laptop computers,
portable radio/ cassette/ CD players, color TVs (up to 50 watts), cellular phone
and camcorder battery chargers, and more.
The Power Force 50™ is equipped with an ON/ OFF switch and power/ charging
indicator light. The AC receptacle is fully marinized, weather-proof and fused.
Added safety features include:
• electronic circuit protection that prevents damage due overloading or insufficient
ventilation;
• automatic shutdown to prevent damage to vehicle’s battery.
Please read the following information carefully before use, to ensure reliable
service and complete safety. Pay particular attention to the CAUTION and
WARNING statements that are provided.
HOW THE Power Force 50™ INVERTER WORKS
The Power Force 50™ inverter is an electronic device that converts low voltage
DC (direct current) electricity from a battery to standard 110-volt AC (alternating
current) household power. In designing the Power Force 50™, Vector™ has
incorporated design techniques previously employed in computer power supplies.
The result of these design innovations is a smaller, lighter and easier-to-use
power inverter.
Principle Of Operation
The Power Force 50™ inverter converts power in two stages. The first stage is a
DC-to-DC conversion process that raises the low voltage DC at the inverter input to
14.5-volts DC. The second stage is the actual inverter stage that converts the high
voltage DC into 110-volts, 60 Hz AC.
The DC-to-DC converter stage uses modern high frequency power conversion
techniques that have replaced the bulky transformers found in less technologically
advanced models. The inverter stage uses advanced power MOSFET transistors in
a full bridge configuration. This ensures excellent overload capability and the
ability to operate reactive loads like lamp ballasts and small induction motors.
Figure 1.
™
Vector™ Power Force 50
Inverter - Principle of
Operation
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Force 50™ Output Waveform
The AC output waveform of the Power Force 50™ is known as a “quasi-sine wave”
or a “modified sine wave”. It is a stepped waveform that is designed to have
characteristics similar to the sine wave shape of utility power. This type of
waveform is suitable for most AC loads, including linear and switching power
supplies used in electronic equipment, transformers, and motors.
The modified sine wave produced by the Power Force 50™ inverter is designed
to have an RMS (root mean square) voltage of 110 volts, which is the same as
standard household power. Most AC voltmeters (both digital and analog) are
sensitive to the average value of the waveform rather than the RMS value. They are
calibrated for RMS voltage under the assumption that the waveform measured will
be a pure sine wave. These meters will not read the RMS voltage of a modified
sine wave correctly. They will read about 20 to 30 volts low when measuring the
output of the Power Force 50™. For accurate measurement of the output voltage
of this unit, use a true RMS reading voltmeter such as a Fluke 87, Fluke 8080A,
Beckman 4410, or Triplett 4200.
™
Figure 2: Power Force 50 - Modified Sine Wave
POWER SOURCE REQUIREMENTS
The Pocket Generator™ battery must provide between 10.5 and 14.5 volts DC
and must be able to supply the necessary current to operate the load. To obtain a
rough estimate of the current (in amperes) the power source must deliver, simply
divide the power consumption of the load (in watts) by 10.
Example: If a load is rated at 50 watts, the power source must be able to deliver:
50 ÷ 10 = 5 amperes
Connection To Load
Connect the Pocket Generator™ to the vehicle’s cigarette lighter socket using the
cigarette lighter plug provided. The Power Force 50™ is equipped with a
standard AC household-type receptacle. Plug the cord from the equipment to be
operated into the AC receptacle. The green LED indicator will illuminate to indicate
that the unit is functioning. Make sure the load requirements of your equipment are
within the parameters of the Power Force 50™ output. If so, turn on the equipment.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTIO N:
DO NOT CONNECT TO AC DISTRIBUTION WIRING:
The Power Force 50™ is engineered to be connected directly to standard
electrical and electronic equipment in the manner described above. Do not
connect the Power Inverter to household or RV AC distribution wiring. Do not
connect the Power Inverter to any AC load circuit in which the neutral conductor is
connected to ground (earth) or to the negative of the DC (battery) source.
CAUTIO N:
RECHARGEABLE APPLIANCES
Certain rechargeable devices are designed to be recharged by plugging them
directly into an AC receptacle. These devices may damage the Power Force 50™.
W hen first using a rechargeable device, monitor its temperature for the initial ten
minutes of use to determine whether it emits excessive heat. If excessive heat is
detected, it is a good indication that the device should not be used with this
inverter. This problem does not occur with the majority of battery-operated
equipment. Most of these devices use a separate charger or transformer that is
plugged into an AC receptacle. The Power Force 50™ is capable of running most
chargers and transformers.
FUSE REPLACEMENT
If the Power Force 50™ is overloaded, replace the main fuse as follows:
1. Open the top flap of the Pocket Generator™, carrying case. The main fuse
holder’s screw-on/ off cap will immediately be visible.
2. Unscrew the fuse holder cap and remove the fuse.
3. Replace with a new 10-amp fuse, if needed.
1
4. Screw fuse holder cap back on.
5. Close case securely.
2
3
4
Fig. 3.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING TIPS
The Power Force 50™ should only be operated in locations that meet the
following criteria:
DRY - Do not allow water or other liquids to come into contact with the inverter.
COOL - Ambient air temperature should be between -20°C and 40°C - ideally
between 15°C and 25°C (60 - 80°F). Do not place the inverter on or near a
heating vent or any piece of equipment which is generating heat above room
temperature. Keep the inverter away from direct sunlight, if at all possible.
VENTILATED - Keep the area surrounding the Power Force 50™ clear to ensure
free air circulation around the unit. Do not place items on or over the inverter
during operation. The unit will shut down if the internal temperature exceeds 90°C.
Restart the unit once it cools down sufficiently.
SAFE - Do not use the Power Force 50™ near flammable materials or in any
locations that may accumulate flammable fumes or gases.
Rated Versus Actual Current Draw of Equipment
Most electrical tools, appliances, electronic devices and audio/ visual equipment
have labels that indicate the power consumption in amps or watts. Be sure that the
power consumption of the item to be operated is below 50 watts. If the power
consumption is rated in amps, simply multiply by the AC volts (110) to determine
the wattage.
Resistive loads are the easiest for the Power Force 50™ to run; however, it will not
run larger resistive loads (such as electric stoves and heaters) which require far more
wattage than the Power Force 50™ can deliver on a continuous basis. Inductive
loads (such as TVs and stereos) require more current to operate than do resistive
loads of the same wattage rating. Induction motors, as well as some TVs, may
require 2 to 6 times their wattage rating to start up. The most demanding in this
category are those that start under load, such as compressors and pumps. Testing
is the only definitive way to determine whether a specific load can be started and
how long it can run. For safety reasons, the unit will simply shut down if it is
overloaded. To restart the unit after a shutdown due to overloading, momentarily
turn off the power to the unit.
Note: The Power Force 50™ will not operate appliances and equipment that
generate heat, such as hair dryers, microwave ovens, and toasters.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Battery Operating Time
1. Always turn power switch on the inverter to OFF position when unit is not in use. If
the switch is left in the ON position, it will drain the Pocket Generator™ battery.
2. WARNING: Never run both AC and DC devices at the same time as this can
damage the Pocket Generator™.
3. Always recharge unit after using.
W ith a full charge, the Power Force 50™ inverter will deliver a minimum
operating time of 30 minutes to one hour. In most instances, 1-3 hours of
operating time is achievable (see chart below).
Estimated Operation Times:
110-VOLT AC APPLIANCE
50 WATT LAMP
APPROX. RUNNING TIME
40 MINUTES
LAPTOP / PRINTER
DESK FAN
1.5 HOURS
2.0 HOURS
STEREO/ CD PLAYER
2.5 HOURS
CELLULAR PHONE, POW ER TOOLS
& CAMCORDER CHARGERS
5 TO 10 HOURS
TROUBLESHOOTING
Protective Features of the Power Force 50™
The Power Force 50™ monitors the following potentially hazardous conditions:
Low Battery Voltage - this condition is not harmful to the inverter but could dam-
age the power source, so the inverter automatically shuts down when input voltage
drops to 10.0 volts. W hen this condition is corrected, the unit may be restarted.
O ver Voltage Protection - the Power Force 50™ will automatically shut down
when the input voltage exceeds 15 volts DC.
Short Circuit Protection - Reverse polarity or a short circuit condition will usually
result in failure of the inverter’s fuse. Immediately disconnect the shorted load and
replace the fuse inside the Pocket Generator™.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Common Audio/ Visual Problems
Problem: Buzzing Sound In Audio Systems
Some inexpensive stereo systems and “boom boxes” emit a buzzing sound from
their speakers when operated from the Power Force 50™ inverter, because the
power supply in the electronic device does not adequately filter the modified sine
wave produced by the inverter. The only solution to this problem is to use a sound
system that has a higher quality power supply internally.
Problem: Television Interference
The Vector™ Power Force 50™ is shielded to minimize interference with TV
signals. However, in some instances, some interference may still be visible,
particularly when the TV signal is weak. Try the following corrective measures:
• Position the Pocket Generator™ as far as possible from the TV set, the antennae,
and the antennae cables. Use an extension cable, if necessary.
• Adjust the orientation of the Pocket Generator™, the antennae cables, and the
TV power cord to minimize interference.
• Make sure that the antennae feeding the TV provides an adequate (“snow free”)
signal and that high quality, shielded antennae cable is used.
Common Power Output Problems
Problem: Lack Of Power Output
Possible Causes
Recommendations
Inverter not adequately
warmed up.
Turn power inverter switch OFF and
then ON again. Repeat if necessary.
Battery voltage
below 10 volts.
Recharge or replace Pocket Generator™ battery.
Equipment being operated
draws too much power.
Reduce load to maximum 50 watts.
Inverter in thermal
shutdown condition.
Allow inverter to cool down. Ensure that there is
adequate ventilation around unit, and load is no
more than 50 watts for continuous operation.
Main fuse failed (blown).
Replace Pocket Generator™ fuse.
Problem: Low Output Voltage
Using average reading voltmeter. Use true RMS reading meter.
Inverter is overloaded.
Reduce load to 50 watts max. to maintain regulation.
Input voltage below 10.5 volts. Keep input voltage above 10.5 volts to maintain regulation.
SPECIFICATIONS: Power Force 50™ Inverter
MAX. CONTINUOUS POW ER . 50 WATTS
PEAK SURGE CAPACITY . . . . . 80 WATTS
LOW VOLTAGE SHUTDOW N ACTIVATION .10.0 VOLTS
WAVE FORM . . . . . . . . . . . . . . . . MAX. SINE WAVE
MAX.EFFICIENCY . . . . . . . . . . . . . ±80% # OF AC RECEPTACLES . . . . . . . . . . . . . . . . . . ONE
NO LOAD CURRENT DRAW . . . . <0.06A
INPUT VOLTAGE RANGE . . . 10 - 15 VDC
FUSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 AMP
13
Download from Www.Somanuals.com. All Manuals Search And Download.
TM
3 YEAR EXTENDED WARRANTY REGISTRATION FORM
Certain Vector Manufacturing, Ltd. products are eligible to be covered to the original pur-
chaser only, for three (3) years from the date of purchase, to be free of defects in materials
or workmanship. Vector Manufacturing, Ltd. disclaims any liability for consequential
damages. In no event will Vector Manufacturing, Ltd. be responsible for any amount of
damages beyond the amount paid for the product at retail. In the event of a defective item,
please ship the item to us, prepaid, with an explanation of the problem, your name, address
and daytime telephone number. Vector Manufacturing, Ltd. will, at its option, replace or
repair the defective part.
The following situations are not covered under this warranty:
✓ Cost of shipment to Vector Manufacturing, Ltd.
✓ Normal wear and tear, including chips, scratches, abrasions, discoloration or fading due
to usage or exposure to sunlight.
✓ Damage caused by misuse, abuse, neglect, alterations, repairs by unauthorized persons,
or failure to follow recommended care and use instructions.
✓ Bulbs, fuses and batteries.
Please activate my Extended Warranty for Model #VEC018-AC.
Name
Street Address
State
City
Zip Code
E-mail
Phone
Fax
Item Purchased
Date of Purchase
Store W here Purchased
UPC Number from package (12 digits)
Form of Payment (US$20.00) Check
Money Order
All Vector Manufacturing, Ltd. products must be registered within (10) days of purchase to
activate this warranty. Mail the completed registration form, along with a copy of the
original sales receipt, and a check or money order for US$20.00 made payable to Vector
Manufacturing, Ltd., to:
ATTN: CUSTOMER SERVICE
VECTOR MANUFACTURING, LTD.
3003 GREENE STREET
HOLLYW OOD, FL 33020
WARRANTY MUST BE PURCHASED W ITHIN 90 DAYS OF PRODUCT PURCHASE DATE.
WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.
Download from Www.Somanuals.com. All Manuals Search And Download.
TM
120 DAY LIMITED WARRANTY REGISTRATION FORM
All Vector Manufacturing, Ltd. products are warranted to the original purchaser only, for 120 days from
the date of purchase, to be free of defects in materials and workmanship. In no event will Vector
Manufacturing, Ltd. be responsible for any amount of damages beyond the retail purchase price of the
product. All Vector Manufacturing, Ltd. products must be registered within (10) days of purchase. To
activate this warranty, mail the completed registration form along with a copy of the original sales receipt
to the address shown below.
TERMS OF REPAIR OR REPLACEMENT: In the event of a defective unit, return the unit to us within 30
days of the date of purchase, and we will replace it, free of charge. If returned after 30 days but within
120 days of the purchase date we will repair the unit or, at our option, replace it free of charge. If we
repair the unit, we may use new or reconditioned replacement parts, at our option. If we elect to replace
the unit, we may replace it with a new or reconditioned one of the same or comparable design. The
repair or replacement unit will then be warranted under the terms of our standard 120 day warranty.
The customer is responsible for shipping charges on all returned items. During the warranty
period, Vector Manufacturing, Ltd. will be responsible for the repair or replacement cost plus the return
shipping charges.
LIMITATIONS: Implied warranties, including those of fitness for a particular purpose and merchantability
(an unwritten warranty that the product is fit for ordinary use), are limited to 120 days from the purchase
date. Vector Manufacturing, Ltd. will not reimburse for loss of time, inconvenience, loss of use of a
product, or property damage caused by a product or its failure to work, or any other incidental or
inconsequential damages, including personal injury.
EXCLUSIONS: This warranty does not cover bulbs, fuses and batteries, defects resulting from normal
wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage or exposure
to sunlight), accidents, damage during shipping to our service facility, alterations, unauthorized use or
repair, neglect, misuse, abuse, failure to follow instructions for care and maintenance, fire, flood, and
Acts of God. If your problem is not covered by this warranty, call our customer service facility at (954)
923-1155 for general repair information and charges. This limited warranty is the only one that applies
to this product, and sets forth all the responsibilities of Vector Manufacturing, Ltd. regarding this product.
There are no warranties which extend beyond those described herein.
STATE LAW RIGHTS: Some states do not allow limitations on how long an implied warranty lasts or the
exclusion or limitation of incidental or consequential damages, so the exclusions or limitations stated
herein may not apply. This warranty gives the purchaser specific legal rights; other rights, varying from
state to state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: W ithin 30 days of the purchase date, return
the unit, along with the dated sales receipt, to the place of purchase for immediate replacement. After
30 days, but within the 120 day warranty period, you may return the product to the address shown
below. We suggest that you retain the original packaging in case you need to ship the unit. W hen
returning a product, include your name, address, phone number, dated sales receipt, and a description
of the reason for return. After repairing or replacing the unit, we will return it to you within four weeks.
VECTOR MANUFACTURING, Ltd.
3003 Greene Street
Hollywood, FL 33020
Please activate my Limited Warranty for Model #VEC018-AC.
I have enclosed a copy of the original sales receipt.
Name
City
Street Address
State
Zip Code
Phone
Fax
E-mail
Item Purchased
Date of Purchase
Store W here Purchased
UPC Number from package (12 digits)
All Vector Manufacturing, Ltd. products must be registered within (10) days of purchase to activate this
warranty. Mail the completed registration form, along with a copy of the original sales receipt, to:
ATTN: CUSTOMER SERVICE
VECTOR MANUFACTURING, LTD.
3003 GREENE STREET
HOLLYW OOD, FL 33020
Download from Www.Somanuals.com. All Manuals Search And Download.
|