INSTALLATION, OPERATION AND CARE OF  
MODEL VCB SERIES CHARBROILERS  
PLEASE KEEP THIS MANUAL FOR FUTURE USE  
GENERAL  
Vulcan-Hart Charbroilers are produced with quality workmanship and material. Proper installation,  
usage and maintenance of your charbroiler will result in many years of satisfactory performance.  
It is suggested that you thoroughly read this entire manual and carefully follow all of the instructions  
provided.  
INSTALLATION  
Before installing, verify that the type of gas supply (natural or propane) agrees with the specifications  
on the rating plate located on the right inside panel. If the supply and equipment requirements do not  
agree, do not proceed with the installation. Contact your dealer or Vulcan-Hart Company immediately.  
UNPACKING  
This charbroiler was inspected before leaving the factory. The transportation company assumes full  
responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check  
for possible shipping damage. If the charbroiler is found to be damaged, save the packaging material  
and contact the carrier within 15 days of delivery.  
Carefully unpack charbroiler and place in a work-accessible area as near to its final installed position  
as possible.  
LOCATION  
The equipment area must be kept free and clear of combustible substances.  
This charbroiler is design certified for installation on a non-combustible counter with 4" (10 cm) legs,  
or on a combustible floor with a 24" (61 cm) high cabinet or stand with the following minimum clearances  
to adjacent wall construction:  
Minimum Clearance  
From:  
Combustible  
Construction  
Non-Combustible  
Construction  
Above Grid Level  
Below Grid Level  
12" (30 cm)  
3" (8 cm)  
3" (8 cm)  
3" (8 cm)  
Back  
Above Grid Level  
Below Grid Level  
9" (23 cm)  
3" (8 cm)  
0"  
0"  
Sides  
– 3 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Floor models must clear 6" (15 cm) from combustible ꢀoors.  
It is recommended that the charbroiler NOT be installed next to open burners or fryers.  
The installation location must allow adequate clearances for servicing and proper operation. A  
minimum front clearance of 24" (61 cm) is required.  
Do not obstruct the ꢀow of combustion and ventilation air. Adequate clearance for air openings into the  
combustion chamber must be provided. Make sure there is an adequate supply of air in the room to  
replace air taken out by the ventilating system. Do not permit fans to blow directly at the charbroiler.  
Avoid wall-type fans which create air cross currents within the room.  
Avoid open windows next to the charbroiler.  
INSTALLATION CODES AND STANDARDS  
In the United States of America:  
1.  
2.  
State and local codes.  
National Fuel Gas Code, ANSI/Z223.1/NFPA #54 (latest edition). Copies may be obtained  
from The American Gas Association, Accredited Standards Committee Z223 @ 400 N. Capital  
St. NW, Washington, DC 2001 or the Secretary Standards Council, NFPA, 1 Batterymarch  
Parch Quincy MA 02169-7471.  
NOTE: In the Commonwealth of Massachusetts,  
All gas appliances vented through a ventilation hood or exhaust system equipped with a  
damper or with a power means of exhaust shall comply with 248 CMR.  
Vapor Removal From Cooking Equipment, NFPA #96 (latest edition). Copies may be obtained  
from The National Fire Protection Association, Batterymarch Park Quincy MA 02169-7471.  
National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The  
National Fire Protection Association, Batterymarch Park, Quincy MA 02169-7471.  
3.  
4.  
In Canada:  
1. Local codes.  
2. CAN/CGA-B149.1 Natural Gas Installation Code (latest edition).  
3. CAN/CGA-B149.2 Propane Installation Code (latest edition), available from The Canadian Gas  
Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.  
CHARBROILERS MOUNTED ON A CABINET, STAND, OR OVEN BASE WITH CASTERS  
When the charbroiler is mounted on a cabinet, stand, or oven base equipped with casters, it must be  
installed with the casters supplied, a connector (not supplied by Vulcan-Hart) complying with either  
ANSI Z21.69 (latest edition) or CAN/CGA-6.16 (latest edition), and a quick-disconnect device  
complyingwitheitherANSIZ21.41(latestedition)orCAN1-6.9(latestedition). Provideagaslinestrain  
relief to limit movement of the appliance without depending on the connector and any quick-disconnect  
device or its associated piping to limit movement of the appliance.  
Should it be necessary to disconnect the strain relief, turn oꢁ the gas supply before disconnection.  
Reconnect the strain relief before turning the gas supply on and returning the broiler to its installation  
position.  
LEVELING  
Place a carpenter's level on the charbroiler. Level the charbroiler front to back and side to side. Unless  
the charbroiler is level, it will not give proper cooking results.  
Casters for the cabinet, stand, or oven base on which the charbroiler can be mounted are of the non-  
adjustable type. Therefore, the ꢀoor must be level. If ꢀoor surface is not level, the charbroiler will  
experience cooking problems.  
– 4 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GAS CONNECTIONS  
CAUTION: Gas supply connections and any pipe joint compound must be resistant to the action  
of propane gases.  
Location of the gas inlet is at the right rear corner. Codes require that a gas shutoff valve must be  
installed in the gas line ahead of the charbroiler.  
Connect gas supply to the charbroiler. Make sure the pipes are clean and free of obstructions.  
3
The gas supply line must be /4" or larger. If flexible or semi-rigid connections are used, the inside  
diameter must be the equivalent of 3/4" iron pipe or larger.  
Natural gas pressure regulators are preset for 5" W.C. (Water Column); propane gas pressure  
regulators are preset for 10" W.C. A pressure regulator is supplied and must be installed outside the  
charbroiler when it is connected to the gas supply.  
All orifices are of the fixed type and require no adjustments.  
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.  
USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.  
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.  
TESTING THE GAS SUPPLY SYSTEM  
When gas supply pressure exceeds 1/2 psig (3.45 kPa), the charbroiler and its individual shutoff valve  
must be disconnected from the gas supply piping system.  
When gas supply pressure is 1/2 psig (3.45 kPa) or less, the charbroiler should be isolated from the gas  
supply system by closing its individual manual shutoff valve.  
FLUE CONNECTIONS  
DO NOT obstruct the flow of flue gases from the flue located on the rear of the charbroiler. It is  
recommended that the flue gases be ventilated to the outside of the building through a ventilation  
system installed by qualified personnel.  
From the termination of the flue to the filters of the hood venting system, a minimum clearance of 18"  
(46 cm) must be maintained.  
Information on the construction and installation of ventilating hoods may be obtained from the standard  
for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest edition), available from The  
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
– 5 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN  
OPERATING, CLEANING OR SERVICING THE CHARBROILER.  
CONTROLS  
Gas Valves  
— Regulate gas flow to the burners.  
— Regulates gas flow to pilot burner.  
Pilot Adjusting Valve  
Gas Pressure Regulator — Regulates gas pressure to the burners.  
LIGHTING INSTRUCTIONS  
1. Turn gas shutoff valve and burner gas valves to the OFF position and wait 5 minutes.  
2. Turn the gas shutoff valve to the ON position.  
3. Turn pilot valve adjusting valve counterclockwise. Light the pilot adjacent to each burner. Adjust  
the pilot screw until the pilot flame is 1/4" (6 mm) high. The flame should have a slight yellow tip.  
Light pilots through observation holes provided on front face of burner box.  
4. Turn the burner gas valve to the ON position.  
5. Air shutters on the burners must be individually adjusted to provide a blue flame. Adjust all traces  
of yellow out of the burner flame.  
6. For complete shutdown, turn the gas shutoff valve, burner gas valves, and the pilot adjustment  
valves to the OFF position.  
7. To relight, follow steps 1-4.  
GRATE POSITION  
The cast iron grates are positioned to lay flat for stock pot use and for cleaning. For broiling, reverse  
grates to slope forward. If you need an extra griddle for your rush hour periods, a lift-off griddle is  
available as an optional extra.  
PREHEATING  
Allow charbroiler to preheat approximately 30 minutes with burners full-on. Rub grates with grease  
before using. The excess grease will run forward and drip onto the front grease trough.  
OPERATING THE CHARBROILER  
1. Load charbroiler.  
2. Turn burners down to prevent overheating which causes the meat to overchar.  
3. Scrape the grates with a wire brush during broiling to keep the grates clean. Do not allow debris  
to accumulate on the grates.  
4. Turn burners to low setting during slack periods to conserve energy.  
– 6 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The charbroiler is a free-vented appliance. All the products of combustion and the heat generated by  
the burners pass through the grates. When meat is placed on the grates, you are blocking the venting,  
thus causing a temperature build-up. The charbroiler, with a complete load, will operate most efficiently  
with burners turned down 1/3 to 1/2  
.
DRIP PAN  
DO NOT allow the drip pan to overflow. Empty the drip pan when three-quarters full to reduce the  
possibility of spillage.  
CLEANING  
Daily  
Thoroughly scrape grate so that grease flows into front grease trough and drip pan. This prevents flare-  
ups.  
Grates may be laid in the flat position with burners full on to burn off fat and carbon. When grates have  
cooled off, brush thoroughly with a steel brush.  
Remove grates and front grease trough for thorough cleaning.  
Remove and empty drip pan. Clean as you would any normal utensil. Rinse thoroughly and wipe dry  
with a soft clean cloth.  
Once charbroiler is clean, replace drip pan, grates, and front grease trough.  
Clean stainless steel surfaces with a mild detergent and water, using a damp cloth, or with a  
commercial stainless steel cleaner. Rinse thoroughly and wipe dry with a soft clean cloth.  
Burner ports and throats should be thoroughly cleaned. Venturi must be free from grease and lint. DO  
NOT insert pick in burner port hole.  
Burner with baffle may be removed periodically for cleaning (use a wire brush).  
– 7 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN  
OPERATING, CLEANING OR SERVICING THE CHARBROILER.  
LUBRICATION  
All moving parts must be checked for wear and lubricated. Contact your local Vulcan authorized  
servicer.  
All valves and controls should be lubricated with a high temperature grease by your local Vulcan  
authorized servicer.  
PILOT LIGHTS  
Pilot lights are to be kept clean and adjusted.  
RECOMMENDED SERVICE FREQUENCY  
Frequency of service maintenance will be largely dependent upon customer usage.  
10-12 hours operation per day, 7 days a week  
4-6 hours a day, 5 days a week  
Limited daily usage  
Every 30-60 days  
Every 120 days  
Every 180 days  
All equipment  
At least once a year  
SERVICE AND PARTS INFORMATION  
To obtain service and parts information concerning this charbroiler, contact the Vulcan-Hart Service  
Agency in your area (refer to listing supplied with the charbroiler), or Vulcan-Hart Company Service  
Department at the address or phone number shown on the front cover of this manual.  
FORM 31167 (Jan., 2001)  
PRINTED IN U.S.A.  
– 8 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  

TechniSat DVD Player TechniBox VIACAM User Manual
Toshiba Camcorder IK VR01A User Manual
Toshiba Film Camera 1080p 60 FP3 User Manual
Toshiba Network Card VF S9 User Manual
Transition Networks Plumbing Product SISTF10xx 141 LRT User Manual
Traulsen Refrigerator UHT27 User Manual
TRENDnet Computer Drive TBW 101UB User Manual
Vizio Mouse TECRA S10 User Manual
Volkswagen Automobile Caravelle User Manual
Weed Eater Lawn Mower WET1742STA User Manual