VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page i
TWO YEAR LIMITED WARRANTY PROGRAM
This limited warranty program is the only one that applies to this product, and it sets forth all the
responsibilities of Vector Manufacturing, Ltd., regarding this product. There is no other warranty, other
than those described herein.
This Vector Manufacturing, Ltd. product is warranted, to the original purchaser only, to be free of defects
in materials and workmanship for two years from the date of purchase without additional charge. The
warranty does not extend to subsequent purchasers or users. Vector Manufacturing, Ltd. will not be
responsible for any amount of damage in excess of the retail purchase price of the product under any
circumstances. Incidental and consequential damages are specifically excluded from coverage under
this warranty.
This product is not intended for commercial use. This warranty does not apply to accessories or damage to
units from misuse or incorrect installation. Misuse includes wiring or connecting to improper polarity
power sources.
RETURN/REPAIR POLICY: Defective products, other than accessories, may be returned postage prepaid
to Vector Manufacturing. Any defective product, other than accessories, that is returned to Vector
Manufacturing within 30 days of the date of purchase will be replaced free of charge. If such a product is
returned more than 30 days but less than two years from the purchase date, Vector Manufacturing will
repair the unit or, at its option, replace it free of charge.
If the unit is repaired, new or reconditioned replacement parts may be used, at Vector Manufacturing’s
option. A unit may be replaced with a new or reconditioned unit of the same or comparable design.
The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty
period. The customer is responsible for the shipping charges on all returned items after 30 days. During
the warranty period, Vector Manufacturing, Ltd. will be responsible for the return shipping charges.
LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and batteries, defects resulting
from normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage
or exposure to sunlight), accidents, damage during shipping to our service facility, alterations, unau-
thorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and maintenance,
fire, flood and Acts of God.
If your problem is not covered by this warranty, call our Technical Support Department at (954) 584-4446
or toll free at 866-584-5504 for general repair information and charges if applicable. You may also
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations
on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential
damages, so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser
specific legal rights; other rights, which vary from state to state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Vector Manufacturing Technical
Support by telephone, fax or mail. We suggest that you keep the original packaging in case you need
to ship the unit. When returning a product, include your name, address, phone number, dated sales
receipt (or copy) and a description of the reason for return and product serial number. After repairing
or replacing the unit, we will make every effort to return it to you within four weeks.
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector Manufacturing.
Enter “VEC012PC” as Model and Jump-starter /12V DC power supply as “Product Type”. All Vector
Manufacturing, Ltd. products must be registered within 10 days of purchase to activate this warranty.
Mail the completed registration form, along with a copy of the original sales receipt to:
ATTN.: CUSTOMER SERVICE / VECTOR MANUFACTURING, Ltd.
4140 SW 28th Way, Ft. Lauderdale, FL 33312
PH: 954-584-4446 • TOLL FREE: 866-584-5504 • Fax: 954-584-5556.
WARRANTY MUST BE PURCHASED WITHIN 10 DAYS OF PRODUCT PURCHASE DATE.
WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.
Download from Www.Somanuals.com. All Manuals Search And Download.
VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page 1
CONTENTS
1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
2. USING VECTOR JUMPER AS A JUMP-START SYSTEM . . . . . . . . . 6
2.1 Easy, Step-by-Step Jump-starting Instructions . . . . . . . . . . . . . 7
3. CHARGING/RECHARGING . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
3.1 110/120 Volt AC Charging . . . . . . . . . . . . . . . . . . . . . . . 9
3.2 12 Volt DC Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3 Estimated Battery Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4. OPERATING AS A PORTABLE POWER SUPPLY . . . . . . . . . . . . . . 9
5. EMERGENCY/WORKLIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6. REPLACEMENT PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.1 Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.2 Battery Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
8. WARRANTY
1
Download from Www.Somanuals.com. All Manuals Search And Download.
VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page 2
Safety information
WARNING:
(Warning statements identify conditions or practices that may result in personal
injury or loss of life)
1) When working with lead acid batteries, always make sure immediate assitance
is available in case of accident or emergency.
2) Always use protective eyewear when using this product: contact with battery acid
may cause blindness and/or severe burns, be aware of first aid procedures in
case of accidental contact with battery acid.
3) There is a risk of explosive gases being released when lead acid batteries are
being charged or discharged. Failure to follow instructions may cause property
damage, explosive hazard, and/or personal injury.
4) When connecting the battery clamps to a discharged battery, and an alarm
sounds - the polarity is reversed.
5) When charging unit from a 110/120 Volt AC electrical outlet in any wet or damp
area, make sure that the outlet used is protected by a ground fault interrupt
(GFI) Switch.
6) When charging the unit near water, do not allow the electrical cords and outlets
to get wet or come near water–electrical shock could result.
7) Jump-start procedures should only be performed in a safe, dry, well-ventilated area.
8) Always store battery clamps in built-in holsters when not in use. Never touch
battery clamps together, this can cause dangerous sparks, power arcing and/
or explosion.
9) When using this unit in proximity to the vehicle’s battery and engine, stand the
unit on a flat, stable surface, and be sure to keep all clamps, cords, clothing
and body parts away from moving vehicle components.
10) Do not wear vinyl clothing when jump-starting a vehicle, friction can cause
dangerous static-electricity sparks. Remove all jewelry or metal objects that
could cause short circuits or react with battery acid.
11) Always disconnect the negative (Black) jumper cable first: followed by the
positive (Red) jumper cable, except for positive ground systems.
12) Never allow red and black clamps to touch each other or another common
metal conductor–this could cause damage to the unit and/or create sparking/
explosion hazard. Always store battery clamps in built-in holsters when not in use.
13) Do not expose battery to fire or intense heat as it may explode. Before disposing
of the battery, protect exposed terminals with heavy-duty electrical tape to prevent
shorting (shorting can result in injury or fire).
14) Do not smoke or use inflammable items (matches, cigarette lighters, etc.) while
working on a vehicle’s battery system.
15) Keep unit out of reach of children (whether stored, or in use)!
FIRST AID
SKIN: If battery acid comes in contact with skin, rinse immediately with water, then
wash thoroughly with soap and water. If redness, pain, or irritation occurs, seek
immediate medical attention.
EYES: If battery acid comes in contact with eyes, flush eyes immediately, for a
minimum of 15 minutes and seek immediate medical attention.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page 3
CAUTION:
Caution statements advise against certain conditions and practices that may
result in damage to vehicles, appliances and/or the jump-starter.
IMPORTANT:
Although this unit is delivered in a partially charged state, you must fully charge it
with the supplied 110/120 Volt AC charger for a full 24 hours before using it for
the first time. You cannot overcharge the unit using the AC charger method.
1) Use only the supplied cords/adapters for recharging this unit. Do not recharge
for more than 3-4 hours maximum using 12 Volt DC method. Recharge unit
after each use.
2) All On/Off switches should be in the OFF position when the unit is charging or
not in use. Make sure all switches are in the OFF position before connection to
a power source or load.
3) Never insert anything other than the supplied power/recharging cords or
recommended appliance power/recharging cords into the 12 Volt DC charging/
power socket on this unit. Do not use any accessory that is not recommended
or provided by the manufacturer.
4) Do not use this unit to operate appliances that draw more than 20 amps.
5) This system is designed to be used only on vehicles with 12 Volt DC battery
systems. Do not connect to a 6 Volt or 24 Volt battery system.
6) This system is not designed to be used as a replacement for a vehicular battery.
Do not attempt to operate a vehicle that does not have a battery installed.
7) Vehicles that have on-board computerized systems may be damaged if vehicle
battery is jump-started. Before jump-starting, read the vehicle’s owners manual
to confirm that external-starting assistance is advised.
8) Excessive engine cranking can damage a vehicle’s starter motor. If the engine
fails to start after the recommended number of attempts, discontinue jump-start
procedures and look for other problems that may need to be corrected.
9) Although this unit contains a non-spillable battery, it is recommended that unit be
kept upright during storage, use and recharging. To avoid possible damage that
may shorten the unit’s working life, protect it from direct sunlight, direct heat
and/or moisture.
10) Check unit periodically for wear and tear. Replace worn or defective parts imme-
diately. Contact Vector Customer Service department toll-free 866-584-5504.
11) Do not attempt to jump-start a frozen battery.
12) Never submerge this unit in water.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page 4
INTRODUCTION
®
Congratulations on selecting the VECTOR JUMP-STARTER and 12 VOLT DC POWER
SUPPLY. This compact jump-starter is unique in the amount of energy it can supply for
its size. The internal battery is a high density sealed, lead-acid battery that stores and
delivers energy comparable to full sized ordinary jump-starters. Please read this
guide carefully before use to ensure optimum performance and avoid damage to the
unit or items that you are using it with.
®
The VECTOR JUMP-STARTER & 12 VOLT DC POWER SUPPLY is a compact, durable
and portable jump-start system for vehicles and boats that have a standard 12 Volt
battery system. This self-contained, rechargeable system will start most vehicles and
boats without the need for a host vehicle or 110/120 Volt AC power supply. It
can also be used as a safe, portable source of 12 Volt DC electric power in remote
locations and/or emergency situations. It is ideal for use with Vector 12 Volt DC
cordless, portable, rechargeable products and MAXXSST DC/AC Power Inverters.
Use the VECTOR JUMP-START SYSTEM to:
•
Jump-start any engine system with a standard 12 Volt DC battery: boat; truck; car; air-
plane; RV; personal watercraft; snowmobile; garden tractor; gasoline engine
generator, etc.
•
Operate: 12 Volt DC fans, inflators, fluorescent worklights, cellular phones (can
quick-charge a cellular phone by using the phone’s 12 Volt DC adapter cord),
spotlights, TVs, portable radios, cassette or CD players, and more.
•
Operate: Certain 110/120 Volt AC Accessories (requires a Vector 12 volt power
inverter, sold separately).
The JUMP-START SYSTEM has an easy-to-read series of LED (Light Emitting Diode)
charge indicators that show when the unit is fully charged, or the level of charge in
the battery. Charge level can be viewed when the charge status push button is
pressed. A 12 Volt DC power accessory socket is provided for use with appliances
that can operate from a vehicle 12 Volt DC accessory outlet. This allows maximum
portability and utility when the Jump-Start Sytem is used in remote locations.
The Jump-Start System can be recharged from any standard 110/120 Volt AC power
source using the supplied AC Recharge Adapter. The adapter barrel connector
attaches to the Recharge Port on the top panel of the jump-starter. A built-in 12 Volt
appliance socket and the appropriate DC/DC charging/adapter cord is used to
recharge the battery from another 12 Volt DC source. When pressed, the CHARGE
STATUS button will show the battery power level status (from Low to Full). The green
LED full indicator illuminates when the unit is fully recharged and charging can be
discontinued. An ON/OFF switch operates the built-in work/emergency light.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page 5
9
8
2
1
5
4
3
11
6
10
7
FIGURE 1A (Front View)
FIGURE 1B (Rear View)
1. Reverse connection indicator
2. Good connection indicator
3. 12 Volt DC Accessory Socket with 20 amp overload protection
4. Battery Level Push Button
5. LED Charging/Battery Level Indicators
6. Heavy-Duty Welding Quality Jumper Cables
7. Heavy-Duty 450 Amp Copper Clamps
8. 110/120 Volt UL approved AC/DC Charging Adapter
9. 12 Volt DC/DC Charging Adapter
10. Light ON/OFF Switch
11. AC Recharge Adapter barrel connector receptacle
ADDITIONAL FEATURES
•
Includes non-spillable, maintenance-free, heavy-duty, new high energy density
19 Amp hour, sealed battery
•
Sturdy and unique compact design provides up to 35 hours of completely portable
12 Volt DC power
•
•
•
•
•
•
Safe to use, transport, and store. Includes an audible polarity alarm
Requires no maintenance (other than recharging) for optimum operation
Automatic taper charge for AC recharge
Audible alarm for reverse polarity
Molded high-impact case is tough and durable
Built-in emergency/worklight with krypton bulb for roadside repairs and use in
remote locations without utility power
CAUTION: Use only adapters supplied with this unit. Never insert any other
adapters into the charging or power receptacles on this unit.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page 6
USE AS A JUMP-START SYSTEM
WARNING:
1. Before using this system to jump-start any vehicle or boat, read and understand
all instructions, safety tips, warnings, cautions and first aid information pro-
vided in this manual and on the product labeling. Additional important infor-
mation may also be provided by the vehicle’s battery system manufacturer.
2. Be aware of first aid procedures before attempting jump-start procedure.
3. Always wear protective eyewear when working with a lead acid-type battery.
4. Do not smoke or use inflammable items (matches, cigarette lighters, etc.) while
working on a vehicle’s battery system.
5. When using this jump-starter in proximity to the vehicle’s battery and engine,
stand the unit on a flat, stable surface, and be sure to keep all cords and
cables away from any moving parts.
6. Check unit periodically for wear and tear. Replace worn or defective parts
immediately; contact Vector Customer Service Department toll-free:
7. Do not attempt to jump-start a frozen battery.
8. NEVER submerge this unit in water.
9. Do not wear vinyl clothing when jump-starting a vehicle, friction can cause
dangerous static electricity sparks. Remove all jewelry or metal objects-they can
cause short circuits or react with battery acid to cause severe burns. Remove
or secure any loose clothing, and restrain long hair, before attempting jump-start
procedure.
10. Lead-acid batteries generate hydrogen gas during normal operation. More
gas is generated when the battery is charging. Hydrogen gas is explosive,
poisonous to breathe and highly flammable.
®
Recommendations for optimum performance of the VECTOR jump-starter:
CAUTION:
1. To avoid possible damage that may shorten the unit’s working life, protect this
unit from direct sunlight, direct heat and moisture.
2. This system is to be used ONLY on vehicles, boats, garden tractors and gaso-
line powered generators with 12 Volt DC battery systems.
3. This system is NOT designed to be installed as a replacement for a vehicle battery.
4. Vehicles that have on-board computerized systems may be damaged if vehicle
battery is jump-started. Before jump-starting this type of vehicle, read the vehicle
owner’s manual to confirm that external-starting assistance is advised.
5. Excessive engine cranking can damage the vehicle’s starter motor. If the engine
fails to start after the recommended number of attempts, discontinue jump-start
procedure and look for other problems that may need to be corrected.
®
6. This VECTOR jump-starter is equipped with an internal, automatic safety switch.
This switch only activates when connections to the battery are correctly made
positive (+) to positive (+) and negative (-) to negative (-). An incorrect connection
will sound an audible alarm indicating an incorrect connection. Should this
alarm sound, remove the clamps and reconnect ensuring proper polarity.
Once the connections are properly made, the internal switch turns on and you
are ready to jump-start the vehicle. This automatic internal safety switch is fully
automatic and requires no action by the user.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page 7
2.1 EASY, STEP-BY-STEP JUMP-STARTING INSTRUCTIONS
This jump-starter is equipped with an automatic ON/OFF that only allows jump-
start energy to flow when proper connections are made to battery and frame. The
automatic ON/OFF works in conjunction with an audible reverse polarity alarm
and a large red LED. If inadvertent reverse polarity occurs, the alarm will sound
and the red LED will light. Disconnect the black clamp (negative clamp) first, then
the red clamp. Reconnect properly and a green LED will light. Wait one minute
and then turn the key. To recap:
CONNECT – Red clamp first, then black clamp.
DISCONNECT – Black clamp first, then red clamp.
1. Turn OFF vehicle ignition and all accessories (radio, A/C, lights, cell phone,
etc.). Place vehicle in park and set the emergency brake.
2. Remove booster clamps from clamp holster.
3. Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM (NEGATIVE
BATTERY TERMINAL IS CONNECTED TO CHASSIS).
3a. Connect positive (+) red clamp to vehicle battery’s positive terminal.
3b. Connect negative (-) black clamp to chassis or a solid, non-moving, metal
vehicle component or body part. Never clamp directly to negative battery
terminal or moving part. If the audible alarm sounds, the polarity is not correct.
Reverse the connections.
4. Procedure for jump-starting POSITIVE GROUND SYSTEMS (NOTE: In the rare
event that the vehicle to be started has a Positive Grounded System (positive
battery terminal is connected to chassis) replace steps 3a and 3b above with
steps 4a and 4b, then proceed to steps 5 through 7 below.
4a.Connect negative (-) black clamp to vehicle battery’s negative terminal
4b. Connect positive (+) red clamp to vehicle chassis or a solid, non-moving,
metal vehicle component or body part. DO NOT CLAMP DIRECTLY TO POSITIVE
BATTERY TERMINAL OR MOVING PART
5. A five (5) second delay is built into this jump-starter unit after the clamp connections
are made. This delay is designed to reduce the possibility of sparking upon
connection. We recommend waiting one (1) minute after making the clamp
connections prior to attempting to start vehicle.
6. Start vehicle (do not turn key for longer than 3-5 seconds).
7. After vehicle starts, remove clamps (disconnect the frame or engine clamp first,
followed by the battery cable) and replace them in the built-in storage holsters.
Squeeze the handles and slide the clamp into position and release your grip.
CAUTION:
1. If engine fails to start, leave ignition key turned off and disconnect the negative
(-) clamp first, then the positive (+) clamp. Try again later – the engine may be
flooded.
2. Recharge jump-start system after each use.
WARNING:
•
Always disconnect the engine or frame jumper clamp first; followed by the battery
jumper clamp
•
There is a risk of explosive gases being released when batteries are charged or
discharged, failure to follow instructions may cause property damage, explosive
hazard, and/or personal injury.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page 8
•
Always use protective eyewear when using this product: contact with battery
acid may cause blindness and/or severe burns
•
Keep out of children’s reach.
ALWAYS store battery clamps in holsters when not in use.
•
FIRST AID
•
SKIN: If battery acid comes in contact with skin, rinse immediately with water,
then wash thoroughly with soap and water. If redness, pain, or irritation occurs,
seek immediate medical attention
•
EYES: If battery acid comes in contact with eyes, flush eyes immediately for a
minimum of 15 minutes and SEEK IMMEDIATE MEDICAL ATTENTION
3.
CHARGING/RECHARGING
For maximum battery life, we recommend the VECTOR® system be kept fully
charged at all times. If the battery is allowed to remain in a discharged state,
battery life will be shortened.
NOTE: Recharging battery after each use will prolong battery life; frequent
discharges between recharges will reduce battery life
IMPORTANT:
•
MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING
•
Charge unit for full 24 hours using AC method, prior to first use
•
Recharge unit fully after each use
Recharge unit every two months, when it has not been used
•
3.1 110/120 Volt AC Charging
1. Simply plug the AC plug of the AC/DC adapter/charger into any standard
110/ 120 volt AC wall outlet.
2. Plug the barrel connector attached to the AC/DC adapter into the small barrel
receptacle on the jump-starter that is marked recharge port.
3. After initial 24 hour charge, charge this device for at least 14-16 hours or until
the green FULL indicator lights. Charge at least once a month when not in use.
4. When charging is completed and the FULL light lights, remove the AC/DC
charger plug and store in a safe place.
®
NOTE: The unit cannot be overcharged using the AC method. The VECTOR
system also comes with a DC/DC charging adapter for recharging the unit from
a 12 volt DC accessory socket in a vehicle or boat .
This recharging method will NOT recharge the unit as effectively as recharging
from a 110/120 volt AC outlet. The 12 Volt DC recharging procedure is
recommended only when it is necessary, as continued use of the 12 Volt DC
recharging procedure may shorten the battery system’s life .
If unit is fully discharged, it is recommended that the vehicle being used for recharging
be left running while the unit is being charged via the 12 Volt DC method.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page 9
WARNING:
Do not recharge for more than 3-4 hours maximum using 12 Volt DC method
3.2 12 Volt DC Charging
1. Insert one end of the DC/DC charging adapter into the 12 Volt DC accessory
receptacle on the vehicle or boat.
2. Insert the plug at the other end of this charging adapter into recharging port
on the front panel of the unit.
3. Charge the unit until the green FULL indicator lights when Charge Switch
Indicator Button is pressed. DO NOT EXCEED 3-4 HOURS MAXIMUM.
4. When charging is completed, remove the power cord and store in a safe place.
3.3 Estimated Battery Life
Table I shows the relationship of the frequency of use between recharging and
the expected number of discharge/recharge cycles.
Table I - Estimated Battery Life between recharges (lifetime of unit’s battery)
Use
1
Recharges
1000+
700+
5
10
500+
4.
OPERATION AS A 12 VOLT PORTABLE POWER SUPPLY
1. Lift up the cover of the unit’s 12 Volt DC accessory receptacle (See Figure 1).
2. Insert the 12 volt DC plug from the appliance into the receptacle on the unit.
3. Switch on the appliance, and operate as usual.
CAUTION:
DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE
THAN 20 AMPS DC
Table II shows the estimated 12 volt DC operation time when using a fully
charged system.
®
Table II - VECTOR as a 12 Volt DC Power Supply
Appliance
Estimated Power Usage
Operating Time
(Watts)
1
(hours)
Cell phone
Fluorescent light
Radio, fan, depth finder
Camcorder, VCR, spotlight
Power tools, bilge pump
Car vacuum
120 (talk time)
4
9
15
24
80
40
24
14
10
2
NOTE: ALL TIMES ARE APPROXIMATE AND BASED UPON A FULLY CHARGED
UNIT.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
VEC012AP•ManuaL 12/02.qxp 12/20/02 5:07 PM Page 10
5.
EMERGENCY WORKLIGHT
The Worklight is controlled by an On/Off switch. Make sure the lamp is turned OFF
when the unit is being recharged or stored.
6.
REPLACEMENT PARTS
For replacement parts (bulbs, batteries, fuses, etc.), contact Vector Customer
Service: (954) 584-4446 or toll-free (866) 584-5504.
6.1 Battery replacement
It is recommended that the unit be returned to Vector Customer Service for
battery replacement: Contact (954) 584-4446 or toll-free (866) 584-5504.
WARNING
• Do not dispose of the battery in fire as this may result in an explosion
• Before disposing of the battery, protect exposed terminals with heavy-duty
electrical tape to prevent shorting (shorting can result in injury or fire)
• Do not expose battery to fire or intense heat as it may explode
6.2 Battery disposal:
This unit contains a maintenance-free, non-spillable, sealed lead-acid battery.
This battery is fully recyclable and should be accepted at any location that
accepts common automotive starter batteries. Examples of places that accept
these batteries are: County or municipal recycling drop-off centers, scrap metal
dealers and retailers who sell automotive replacement lead acid starter batteries.
For more information on recycling this battery, call toll-free (877) 288-7722.
7.
SPECIFICATIONS
Model No . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VEC012AP
Peak Ampere . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1200 Amps
Boost Ampere . . . . . . . . . . . . . . . . . . 450 Instantaneous Cranking Amps
HEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.75 in. (29.85 cm)
WIDTH
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.625 in (29.53 cm)
DEPTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.375 in (11.1125 cm)
WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 lbs. (8.16 Kg)
Battery Type
12Volt, 19AH/20HR Sealed, Rechargable
Non-Spillable, Maintenance-free,
Jumper Cables . . . . . . . . . . . . . . . . . . . . . . .Heavy Duty, Welding Cable
Cables Clamps . . . . . . . . . . . . . . . . . . . . . . . 450 Amp, Copper Clamps
Area Light . . . . . . . . . . . . . . . . . . . . . . . Three high Intensity White LEDs
Accessory Socket . . . . . . . . . . . . . . . . . .Self-Resetting Breaker 20 Amps
DC Charging Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Volt DC
AC Charging Adapter . . .110/120 Volt AC (700mA, 12 Volt DC Output)
Reverse Polarity Detection . . . . . . . . . . . . . . . . . . . . . . . . . .2 Volts (min)
10
Download from Www.Somanuals.com. All Manuals Search And Download.
|