Unisar Thermometer BR101 User Manual

Download from Www.Somanuals.com. All Manuals Search And Download.  
KEY FEATURES  
BATTERY INSTALLATION  
(See diagram below)  
• No probe cover needed  
• Probe can be wiped clean with water  
or alcohol  
1. Replace the battery when  
the “low battery” warning  
symbol appears.  
• Each temperature reading takes only 1  
second  
2. Slide the battery compartment lid off.  
• A second temperature reading can be  
taken after just 5 seconds  
3. Insert one 3-volt CR-2032 lithium  
• 512 temperature scanning sequences per  
second ensure reliable accuracy  
battery with the anode (+) facing up.  
• Ergonomic design makes the thermometer  
comfortable and easy to use  
4. Replace the battery compartment lid by  
sliding it forward.  
• Stores and recalls last 10 readings  
• Small and lightweight design makes it  
ideal for home use and traveling  
• Powers off automatically after one minute  
of non-use to ensure a long battery life for  
at least 5,000 measurements  
• Easy to read LCD display  
• Temperature shown in Fahrenheit (F) or  
Celsius (C)  
The Ear Thermometer is a Personal Care  
Product and cannot be returned to the retailer.  
All exchange and refund requests should be  
directed to the BébéSounds® Help Desk  
at 1-888-232-6476  
Mon-Fri from 9:00AM – 5:00PM EST  
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
into the ear to allow the  
probe tip to continuously  
scan the ear canal. This  
will ensure an accurate  
temperature measurement  
(See Fig. 4). After one  
second release the  
INSTRUCTIONS FOR USE  
1. Press and realease the  
POWER/SCAN button  
and the system will start  
Figure 4  
Figure 1  
its self-testing cycle  
(See Fig. 1).  
POWER/SCAN button  
for a temperature reading.  
2. Once the self-testing is  
completed, the display  
will show the last temper-  
ature recorded. (See Fig.  
2). This indicates that the  
thermometer is ready for  
you to use.  
Figure 2  
5. A beep will indicate the  
end of the temperature  
measurement. (See Fig. 5).  
Remove thermometer from  
ear canal and view the  
temperature.  
Figure 5  
3. Press the POWER/SCAN  
button without releasing  
it so it will perform the  
automatic scanning  
6. To change the reading from Celsius to  
Fahrenheit, press the POWER/SCAN  
button without releasing it and then  
press the MEM button.  
Figure 3  
sequences. The word Lo  
may appear indicating  
the temperature  
7. A smiling face will  
registering is lower than  
93.2°F/34°C (See Fig. 3).  
appear in the display to  
indicate a temperature  
Figure 6  
lower than 100.4°F/38°C  
4. Keeping the POWER/SCAN button  
depressed, insert the probe into the ear  
canal. The probe must be inserted well  
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
while a frowning face  
accompanied by one  
long and two short beeps  
will indicate a  
temperature higher than  
100.4°F/38°C  
simply press the MEM button. The  
memory symbol (top left corner), the  
number of the reading and the tempera-  
ture reading will appear on the display  
(See Fig. 11).  
Figure 7  
(See Figs. 6 & 7).  
11. To get the most precise temperature  
reading wait five seconds before taking  
a temperature again.  
8. The thermometer’s  
temperature range is  
Figure 8  
Figure 9  
between 93.2°- 109.4°F  
and 34°- 43°C. A Lo  
reading appears when  
the temperature measured  
is lower than 93.2°F/34°C,  
12. The temperature will vary between both  
ears so try to take the temperature from  
the same ear each time.  
while a Hi reading appears when the  
temperature measured is higher than  
109.4°F/43°C (See Figs. 8 & 9).  
9. If the ambient temperature  
is outside the thermome-  
Figure 10  
ter’s range (see Technical  
Specifications), “Err” will  
appear in the display  
(see Fig. 10).  
The Ear Thermometer is a Personal Care  
Product and cannot be returned to the retailer.  
All exchange and refund requests should be  
directed to the BébéSounds® Help Desk  
at 1-888-232-6476  
10. The Ear Thermometer  
stores and recalls the last  
10 temperature readings.  
Figure 11  
Mon-Fri from 9:00AM – 5:00PM EST  
To recall prior readings  
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNDERSTANDING THE  
SYMBOLS  
CARE AND CLEANING  
1. The ear thermometer is a delicate  
electronic device. Although the probe  
is waterproof, the body of the  
Degrees of temperature  
Celsius  
thermometer is not. Therefore, to ensure  
proper functioning, avoid direct contact  
of the body of the thermometer with  
water or other liquids.  
2. Clean the probe with a soft cloth  
moistened with either water or alcohol.  
Clean the body of the thermometer with  
a soft dry cloth. Never use an abrasive.  
Fahrenheit  
Temperature is being scanned  
3. Avoid touching the probe with your  
fingers.  
Memory symbol and number of  
the recorded reading  
4. Do not expose the thermometer to direct  
sunlight.  
Low battery warning  
5. Keep out of the reach of children and in  
the storage case when not in use.  
The optimal storage temperature is  
between 4°~122°F/-20°~50°C.  
Smiling face indicating  
temperature lower than  
100.4°F/38°C  
6. The ear thermometer is designed for  
taking temperatures from the ear canal  
only. Do not use it to take rectal, oral,  
or armpit temperatures.  
Frowning face indicating  
temperature higher than  
100.4°F/38°C  
7. Do not disassemble the thermometer.  
10  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: According to extensive clinical  
examinations, the temperature readings  
given by an ear thermometer are equivalent  
to those given by its oral counterparts.  
NOTE: If you believe your thermometer  
is defective or otherwise not operating  
properly, please check the battery first.  
If the thermometer is still not operating  
properly or if you are having any other  
technical problems, please contact:  
Use of this ear thermometer should not  
replace a visit to your doctor.  
Unisar Inc.  
TROUBLESHOOTING  
1. Consistent low temperature readings  
15 West 36th Street  
New York, NY 10018  
1-888-232-6476  
a. The probe is not positioned properly in  
the ear canal. The tip of the probe must  
be snug and fully seated against the  
opening of the ear canal. Failure to  
properly position the probe may lead to  
a low temperature reading.  
b. The waterproof lens is dirty. Clean the  
lens with a soft cloth moistened with  
water or alcohol.  
TECHNICAL SPECIFICATIONS  
• For household use only  
• Temperature readings are to the nearest  
0.1°F or °C  
• Temperature measurement range:  
93.2° ~ 109.4°F/34°C ~ 43°C  
• Ambient operating environment:  
60.8 ~ 104°F (16° ~ 40°C)  
• Ambient storage environment:  
-4° ~ 122°F/-20° ~ 50°C  
2. The measurement is out of the range  
of the ear thermometer  
a. Switch the ear thermometer on before  
positioning it in the ear. Please  
properly position the ear thermometer  
in the ear canal and then repeat the  
measurement.  
3. Low battery warning  
a. Battery needs to be replaced.  
See Battery Installation section of the  
• Laboratory accuracy against an infrared  
reference source:  
95°~102.2°F/35° ~ 39°C: +/- 0.4°F/0.2°C  
less than 96.8°F/36°C: +/- 0.5°F/0.3°C  
greater than 102.2°F/39°C: +/-0.5°F/0.3°C  
• Requires one 3-volt CR-2032 battery  
(included)  
• Equipment is not category AP/APG  
manual.  
12  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED PRODUCT WARRANTY  
APPLIED STANDARDS AND  
APPROVALS  
The BébéSounds® Ear Thermometer,  
distributed by Unisar Inc., has a limited  
warranty against defects for a period of  
three years from the original purchase date.  
Battery life or damage due to misuse or  
abuse are excluded from this warranty.  
FDA approved. For home use only.  
This product conforms to the provisions of  
the EC directive MDD(93/42/EEC).  
The following standards apply to design  
and/or manufacturing of the products:  
• ASTM E 1965-98: Standard Specification  
for infrared thermometers for intermittent  
determination of patient temperature.  
In-Warranty Procedure  
In the event service is required due to  
defect or malfunction during the warranty  
period, Unisar Inc. will replace or repair the  
product under warranty. The repair or  
replacement of the defective item will be  
free of charge. Repair or replacement of  
the defective item is subject to verification  
of the malfunction or defect when delivered  
to:  
• EN 980:1997: Graphical symbol for  
use in the labeling of medical devices.  
• EN 60601-1: Medical electrical  
equipment – Part 1: General require-  
ment for safety.  
• EN60601-1-2: Medical electrical  
equipment – Part 2: Collateral stan-  
dard: Electromagnetic compatibility –  
Requirements and tests.  
Unisar® Service Center  
15 West 36th Street  
New York, NY 10018 USA  
Please enclose dated proof of purchase with  
your return.  
14  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Ear Thermometer is a Personal Care  
Product and cannot be returned to the retailer.  
All exchange and refund requests should be  
directed to the BébéSounds® Help Desk  
at 1-888-232-6476  
Mon-Fri from 9:00AM – 5:00PM EST  
Unisar Inc.  
15 West 36th Street  
New York, NY 10018  
1-800-233-1196  
visit us at  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Teac MP3 Player WAP 4500 User Manual
Toshiba DVD Player SD 330ESB User Manual
Toshiba DVD Player SD KP19 User Manual
Tricity Bendix Freezer TBFF 73 User Manual
Turbosound Speaker Impact 50 User Manual
Ultralink Network Card UL2 DA User Manual
Ultra Products Network Card ULT40120 User Manual
Uniden Scanner UBC 245XLT User Manual
Universal Remote Control Universal Remote UR5U 8700L IP User Manual
Victory Refrigeration Refrigerator GRS 1 S7 User Manual