UltraLink 2
Quick Start Guide
UL2-SA (Single Access)
UL2-DA (Dual Access)
FRONT
REAR
To KVM
To Computer
Switch 1 - Power Option switch
Switch 2 - unit configuration switch
Located on the side of all models
(S1 and S2 Off for normal operation)
To configure the UL 2, the default IP address (192.168.1.42) must be changed to be compatible with
your network. There are two different ways to configure the UltraLink 2’s network information, using the
USB ports or a network crossover cable. Following explains both methods.
1- Unit Configuration via USB ports
The configuration procedure using USB connections is shown below.
Computer Requirements
Dual access model
connect to lower
PS/2 ports
OS – XP or Vista
2 – USB 2.0 ports
DO NOT
Connect the monitor
HD15 connectors
PS/2 to USB
adapters
CPU Adapter
Cable
1. Position Switch 2 on the UltraLink 2 to the ON position
2. Disconnect unit from the network if connected (computer and monitor should be ON)
3. Connect the PS/2 to USB adapters to the CPU adapter cable and to the computer’s USB ports.
4. Connect the PS/2 connectors on the other end of the cable to the UltraLink 2’s PS/2 connectors.
5. When the keyboard and mouse connectors are connected to the UltraLink 2, the computer
operating system will detect the UltraLink 2 unit as a removable drive.
6. Using Windows explorer, select the UL-2 removable drive and you should see a text file name
“Config.txt”. Edit this text file using a text editor like Notepad and change the IP Address, IP
NetMask and IP Gateway to the IP address information assigned to the UltraLink 2 unit. Also the
Unit name, Use DHCP, and Reset Admin Password options can be selected here. Complete
instructions are included in the “Config.txt” file.
7. When changes are complete, save the file and close the text editor.
Download from Www.Somanuals.com. All Manuals Search And Download.
Change the IP address, network mask, and other network information that has been
assigned to the UltraLink 2. The VNC port (5900) and HTTP Port (80) should only be
changed if they conflict with existing network settings. If you choose to use DHCP, check
the box adjacent to “Use DHCP”. When complete “Save” the new IP information.
NOTE: When the unit is configured properly and connected to the network, if you have
chosen the option “Use DHCP” the IP address will change to whatever IP address your
DHCP server assigns it. Once the IP address has been changed, UltraLink 2 will lose the
connection to the computer used for configuration. Please see the user’s manual for
additional DHCP information.
When complete, change the IP information on the computer used to connect to the
UltraLink 2 back to the original values.
3- Unit Installation / Cabling
Single Access Model
1- Connect the supplied CPU adapter cable from the keyboard,
monitor, and mouse ports on the UltraLink 2 to the
corresponding ports on the computer to access.
2- Connect a standard network cable from the RJ45 connector
on the UltraLink 2 to your network.
Dual Access Model
1- Connect the supplied CPU adapter cable from the keyboard,
monitor, and mouse ports on the UltraLink 2 (bottom ports) to
the corresponding ports on the computer to access.
2- Connect a local keyboard, monitor, and mouse to the
corresponding ports (top ports) on the UltraLink 2.
3- Connect a standard network cable from the RJ45
connector on the UltraLink 2 to your network.
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting to a KVM switch
1- Connect the supplied CPU adapter cable from the
keyboard, monitor, and mouse ports on the
UltraLink 2 to the corresponding ports on the
KVM switch to access.
2- Dual model only - Connect a local keyboard,
monitor, and mouse to the corresponding ports on
the UltraLink 2 (top ports).
3- Connect a standard network cable from the RJ45
connector on the UltraLink 2 to your network.
3- Operating Instructions (Single and Dual access models)
With all cabling in place, the default IP address changed to be compatible with your network, and power
applied to the connected computer or switch, access to the connected computer can now be made.
Connecting to the computer can be made from any computer with access to the network UltraLink 2 is
connected to. From a network workstation, start internet explorer or other web browser. Type in the
assigned IP address given to UltraLink 2 in the URL field. The below browser screen will display. Click
on “Connect using built-in Java VNC Viewer”. This will install a temporary small java applet on the
connecting computer and then display the remote computers video.
Click on the “Configure” tab in the upper right corner of the VNC viewer window. This will display
the configuration options. Click on each tab as needed to change/update the information. Below
briefly describes each configuration tab.
User Accounts tab
Allows you to create and manage up to sixteen separate user accounts, each with separate
access permissions. Account #1 is the admin account. Enter User name, password. Tick/un-tick
the Local and Remote options that are appropriate to the user.
Unit Configuration tab
Allows you to alter settings within the UltraLink-2. You can define the keyboard, set-up the admin
account, assign a name to the unit, screensaver time and encryption options
Time and Date Configuration tab
Set the time and date, this time stamps the log files
Network Configuration tab
(Similar to the initial network configuration)
Host Configuration tab
Allows configuration of various details for each host system connected to UltraLink 2. 128 entries
max, Add host names, Users, Hotkey, and Power Control Sequence.
Logging and Status tab
Provides various details about the user activity on the UltraLink 2.
Return to Host tab
Exit the configuration menu system and return to the host computer.
3
10707 Stancliff Road
Houston, Texas 77099
Phone: (281) 933-7673
WWW.ROSE.COM
UL2-QS rev
Copyright © 2008 Rose Electronics