Transition Networks TV Converter Box CSDTF1022 100 User Manual

COMPLIANCE INFORMATION  
UL Listed  
C-UL Listed (Canada)  
CISPR22/EN55022 Class A + EN55024  
CE Mark  
T1/E1 Twisted-Pair Copper to Fiber  
Slide-In-Module Media Converters  
FCC Regulations  
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant  
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful  
interference when the equipment is operated in a commercial environment. This equipment generates,  
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the  
instruction manual, may cause harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause harmful interference, in which case the user will be  
required to correct the interference at the user’s own expense.  
CSDTF10xx*-100  
USER’S GUIDE  
TRANSITION Networks CSDTF10xx-100 series media converters, designed to be  
installed in a PointSystemConversion Centerchassis, encode and decode T1 or  
E1 twisted-pair copper signals over duplex fiber-optic cable to extend the distance  
and transmission reliability of high speed T1 or E1 data traffic.  
Canadian Regulations  
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on  
the radio interference regulations of the Canadian Department of Communications.  
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables  
aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique  
édicté par le ministère des Communications du Canada.  
CSDTF1011-100  
Provides an RJ-45 twisted pair copper  
connector for T1 or E1 signals and a set  
of RX/TX ST connectors to 850 nm  
European Regulations  
Warning  
This is a Class A product. In a domestic environment this product may cause radio interference in which  
case the user may be required to take adequate measures.  
PWR  
PWR  
PWR  
PWR  
COL  
SDC SDF PWR  
LOOP  
SDC SDF PWR  
LOOP  
SDC SDF PWR  
RXF  
LKS  
LKM  
LKS  
LKM  
LA  
LKS  
LKM  
LKS  
LKM  
LNK  
RXF  
RXC  
LOOP  
RXC  
TX  
LKC  
TX  
TX  
TX  
TX  
Link Alert  
TX  
RX  
multimode duplex fiber-optic cable.  
E
D
TX  
RX  
Achtung !  
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes  
Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen  
werantwortlich ist.  
SET  
RX  
TX  
RX  
TX  
RX  
TX  
RX  
TX  
RX  
CSDTF1012-100  
0
50‰  
Provides an RJ-45 twisted pair copper  
connector for T1 or E1 signals and an  
RX/TX ST connector to 1300 nm  
RX  
RX  
RX  
RX  
Attention !  
CFETF100  
CSDTF100  
CECF100  
CFMFF100  
CFM  
CFMFF100  
CFETF110  
CFMFF100  
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des  
interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques  
appropriées  
singlemode duplex fiber-optic cable.  
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE  
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in  
damage to the public telephone network.  
CSDTF1013-100  
CSDTF1015-100 (long haul)  
Provides an RJ-45 twisted pair copper  
connector for T1 or E1 signals and an  
RX/TX SC connector to 850 nm  
Provides an RJ-45 twisted pair copper  
connector for T1 or E1 signals and an  
RX/TX SC-LH connector to 1300 nm  
singlemode duplex fiber-optic cable.  
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten  
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur  
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen  
einschliesslich der gegenseitigen Anerkennung ihrer Konformität.  
multimode duplex fiber-optic cable.  
CSDTF1014-100  
CSDTF1022-100 (long haul)  
Provides an RJ-45 twisted pair copper  
connector for T1 or E1 signals and an  
RX/TX SC-SM connector to 1300 nm  
singlemode duplex fiber-optic cable.  
Provides an RJ-45 twisted pair copper  
connector for T1 or E1 signals and an  
RX/TX ST connector to 1300 nm  
singlemode duplex fiber-optic cable.  
CSDTF10xx in the Network . . . . . . .2  
Installation . . . . . . . . . . . . . . . . . . . .3  
Operation . . . . . . . . . . . . . . . . . . . . .7  
Fault Isolation and Correction . . . . .8  
Cable Specifications . . . . . . . . . . . .10  
Technical Specifications . . . . . . . . .11  
Compliance Information . . . . . . . . .12  
Trademark Notice  
All registered trademarks and trademarks are the property of their respective owners.  
*In CSDTF10xx model designation, 10  
represents the T1 or E1 RJ-45 connector;  
xx represents the selectable fiber connector  
installed on the media converter.  
Copyright Restrictions  
© 2001, 2002 TRANSITION Networks.  
All rights reserved. No part of this work may be reproduced or used in any form or by any means –  
graphic, electronic, or mechanical – without written permission from TRANSITION Networks.  
Printed in the U.S.A.  
Download from W33w2w01.S.Comanuals.com. All Manuals Search And Download.  
Dry-Contact Relay  
CABLE SPECIFICATIONS (continued)  
RJ-45 dry-contact relay opens if power, signal detect/copper or signal  
Twisted-Pair Copper Cable  
detect/fiber are lost.  
Operational rating on pins 3 and 6: 0-30VDC maximum 1A  
Twisted pair connection requires two active pairs. The two active pairs  
in a T1/E1 network are pins 1 & 2 and pins 4 & 5. Use only dedicated  
wire pairs (such as blue/white & white/blue, orange/white &  
white/orange) for the active pins.  
Relay  
3
RJ-45  
Category 3 or better twisted-pair copper wire is required. Either shielded  
twisted-pair (STP) or unshielded twisted-pair (UTP) can be used.  
6
T1:  
Gauge  
24 to 22 AWG  
Attenuation  
Differential Characteristic Impedance  
2.6 dB/100 meters @ 1.0 MHz  
100 ±10%  
Switch-Selectable Configurations  
T1 COPPER RJ-45  
E1:  
Configured as either "long haul" or short haulon 100 ohm cable, with  
Gauge  
24 to 22 AWG  
Attenuation  
Differential Characteristic Impedance  
2.6 dB/100 meters @ 1.0 MHz  
120 ±10%  
a variety of selectable distance settings.  
E1 COPPER RJ-45  
Configured as either "long haul" or short haulon 120 ohm cable.  
STRAIGHT-THROUGH/CROSSOVER RJ-45  
Allows straight-through cable to be used where crossover-configuration  
cable is required.  
Switch-Selectable Functions  
LOOPBACK TEST FUNCTION  
A loopback switch facilitates installation and network debug procedures.  
The path for the CSDTF10xx loopback is shown:  
Fiber  
TP  
TP  
TRANSMIT ALL ONES FUNCTION  
A selectable Transmit All Ones switch on the fiber interface and on the  
twisted-pair interface allows for insertion of an all onespattern on that  
interface when signal detect is lost, which creates an alarm condition at  
the equipment connected to the interface.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
CAUTION: Wear a grounding device and observe electrostatic discharge  
precautions when setting switch and when installing Media Converter Slide-in-  
Module in the Media Conversion Center. Failure to observe this caution could  
result in damage to, and subsequent failure of, the Media Converter Slide-in-  
Module.  
CABLE SPECIFICATIONS  
Fiber Cable  
Bit error rate:  
10-9  
MULTIMODE  
Set Loopback Test Switch  
Fiber Optic Cable Recommended:  
Optional:  
62.5 / 125 µm multimode fiber  
100 / 140 µm multimode fiber  
85 / 125 µm multimode fiber  
50 / 125 µm multimode fiber  
850 nM  
NOTE: The Loopback Test switch, located on Media Converter Slide-in-  
Module front panel, allows the network administrator  
to enable a loopback test for installation and network  
debug procedures.  
Loop  
CSDTF1011-100  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Typical Maximum Cable Distance*:  
CSDTF1013-100  
min: -14.0 dBm  
min: -25.0 dBm  
2 kilometers  
max: -12.0 dBm  
max: -12.0 dBm  
Use small flatblade screwdriver or similar device to set recessed switches.  
Refer to drawing for switch locations.  
850 nM  
Set 3-Position Jumper  
Fiber-optic Transmitter Power:  
Fiber-optic Receiver Sensitivity:  
Typical Maximum Cable Distance*:  
min: -14.0 dBm  
min: -25.0 dBm  
2 kilometers  
max: -12.0 dBm  
max: -12.0 dBm  
NOTE: Jumper is located on Media Converter Slide-in-Module circuit board.  
Use small needle-nosed pliers or similar device to set  
jumper. Refer to drawing for jumper positions.  
SINGLEMODE  
H
S
Fiber Optic Cable Recommended:  
CSDTF1012-100  
Fiber-optic Transmitter Power:  
Fiber-optic Receiver Sensitivity:  
Typical Maximum Cable Distance*:  
CSDTF1014-100  
9 µm singlemode fiber  
1300 nM  
HARDWARE MODE  
HARDWARE Converter mode is determined by  
4-position switch settings below.  
min: -21.0 dBm  
min: -25.0 dBm  
8 kilometers  
max: -14.0 dBm  
max: -14.0 dBm  
H
S
SOFTWARE Converter mode is determined by most-  
recently-saved on-board microprocessor settings.  
SOFTWARE MODE  
1300 nM  
Fiber-optic Transmitter Power:  
Fiber-optic Receiver Sensitivity:  
Typical Maximum Cable Distance*:  
CSDTF1015-100 (long haul)  
Fiber-optic Transmitter Power:  
Fiber-optic Receiver Sensitivity:  
Typical Maximum Cable Distance*:  
CSDTF1022-100 (long haul)  
Fiber-optic Transmitter Power:  
Fiber-optic Receiver Sensitivity:  
Typical Maximum Cable Distance*:  
min: -21.0 dBm  
min: -27.0 dBm  
8 kilometers  
max: -14.0 dBm  
max: -14.0 dBm  
Set MDI/MDI-X Switch  
NOTE: The MDI/MDI-X switch, located on Media Converter Slide-in-Module  
circuit board, allows the network administrator to use straight-through cable  
in installations where crossover-configuration cable is required.  
1300 nM  
min: -15.0 dBm  
min: -27.0 dBm  
15 kilometers  
1300 nM  
min: -15.0 dBm  
min: -25.0 dBm  
15 kilometers  
max: -5.0 dBm  
max: -14.0 dBm  
Use small flatblade screwdriver or similar device to set recessed switches.  
Refer to drawing for switch settings.  
max: -5.0 dBm  
max: -14.0 dBm  
MDI-X  
MDI  
*Actual distance dependent upon physical characteristics of network installation.  
1
2
1
2
RTIP  
TTIP  
RTIP  
RTIP  
Twisted  
Pair #1  
Twisted  
Pair #1  
RRING  
TRING  
RRING  
RRING  
4
5
TTIP  
RTIP  
4
5
TTIP  
TTIP  
Twisted  
Pair #2  
Twisted  
Pair #2  
TRING  
RRING  
TRING  
TRING  
Connectors for unlike devices  
Connectors for like devices  
Set 8-Position Switch  
NOTE: The eight-position switch, located on Media Converter Slide-in-  
Module circuit board, allows the network administrator to configure the  
media converter for network conditions.  
Use small flatblade screwdriver or similar device to set recessed switches for  
Download from Www.Somanuals.com. All Manuals Search And Download.  
site installation. Refer to drawings at right for eight-position switch settings.  
NOTE:  
LEFT SWITCH SET  
FAULT ISOLATION and CORRECTION  
If the media converter fails, isolate and correct the failure by determining the  
answers to the following questions and then taking the indicated action:  
T1 must be selected (LEFT  
SWITCH SET #4 UP) for RIGHT  
SWITCH SET to have any effect.  
1
2
3
4
1
2
3
4
If E1 is selected (LEFT SWITCH SET  
#4 DOWN), RIGHT SWITCH SET is  
ignored and the default is E1  
3.0V 120cable.  
toward chassis  
toward network connectors  
1.  
Is the P(o)W(e)R LED on the media converter illuminated?  
NO  
NETWORK Switch Settings  
1 2 3 4  
Is the media converter inserted properly into the chassis?  
Is the power cord properly installed in the chassis and at the  
external power source?  
If T1 and short haul are  
Transmit All Ones onto Fiber  
on loss of TP Carrier Detect  
UP= Enabled  
selected (LEFT SWITCH SET #3  
UP, #4 UP), but RIGHT SWITCH  
SET is not set to a valid short  
haul value, the short haul  
default is DSX-1 0-133cable.  
Does the external power source provide power?  
Contact Technical Support: (800) 260-1312.  
YES  
Transmit All Ones onto TP  
on loss of FiberCarrier Detect  
UP= Enabled  
Proceed to step 2.  
If T1 and long haul are  
selected (LEFT SWITCH SET #3  
DOWN, #4 UP), but RIGHT  
SWITCH SET is not  
2.  
Is the SDF (Signal Detect/Fiber) LED illuminated?  
NO  
Long Haul/Short Haul (T1 only)  
UP= Short Haul  
Check fiber cables for proper connection.  
Verify that TX and RX cables on media converter are connected to  
RX and TX ports, respectively, on other media converter.  
Contact Technical Support: (800) 260-1312.  
set to a valid  
long haul value,  
the long haul  
default is 0db  
100cable.  
KEY  
=
UP  
T1/E1 Selection  
UP= T1  
YES  
=
DOWN  
Proceed to step 3.  
3.  
Is the SDC (Signal Detect/Copper) LED illuminated?  
NO  
SHORT HAUL Switch Settings*  
1 2 3 4  
RIGHT SWITCH SET  
1
2
3
4
1
2
3
4
Check twisted pair cables for proper connection.  
Check RJ-45 Pinning Switch for correct twisted pair cable  
configuration.  
DSX-1 533'-655'  
100 ohm cable  
toward chassis  
toward network connectors  
Check integrity of device attached to media converter by twisted-  
pair cable.  
DSX-1 399-533’  
100 ohm cable  
LONG HAUL Switch Settings*  
1 2 3 4  
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.  
YES  
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.  
-22.5db  
DSX-1 266-399’  
100 ohm cable  
100 ohm cable  
-15db  
100 ohm cable  
DSX-1 133'-266'  
100 ohm cable  
-7.5db  
100 ohm cable  
DSX-1 1 0-133’  
and ANSI T1.403  
100 ohm cable  
0db  
100 ohm cable  
DSX-1 6.0V  
100 ohm cable  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*Right switch set #4 not used  
*Right switch set #4 not used  
Power the Slide-In-Module  
INSTALLATION (continued)  
Install Slide-In-Module in PointSystemChassis  
NOTE: The Slide-In-Module is powered through the Conversion  
Center.  
CAUTION: Any Slide-in-Module installation slot in which a Media Converter  
Slide-in-Module is NOT installed MUST have a protective plate instead.  
Failure to observe this caution will void Class A and/or Class B compliance.  
OPERATION  
NOTE: Install Media Converter Slide-in-Modules in any slot, in any order.  
After installation, the media converter should function without operator  
intervention.  
1. Carefully slide Media Converter Slide-in-Module into installation slot,  
aligning Media Converter Slide-in-Module with installation guides.  
Status LEDs  
NOTE: Ensure that Slide-in-Module is firmly seated against backplane.  
Use the status LEDs to monitor media converter operation in the network.  
2. Secure Slide-in-Module by securing panel fastener screw (attached to  
Slide-in-Module) to chassis front.  
SDC  
Signal Detect/Copper - Steady LED  
indicates twisted-pair copper link is up.  
3. Install protective plate at EVERY Slide-in-Module installation slot in  
which a Media Converter Slide-in-Module is not installed by securing  
attached protective plate panel fastener screw to chassis front.  
SDC SDF PWR  
LOOP  
Flashing LED (once/second) indicates  
transmitting on link if other link is down.  
Flashing LED (5 times/second) indicates All  
Ones detected on Link.  
Install Cable  
COPPER  
SDF  
Signal Detect/Fiber - Steady LED indicates fiber link is up.  
T1 100 OHM (RJ-45 CONNECTOR)  
Flashing LED (once/second) indicates transmitting on link if  
other link is down.  
1. Locate or build twisted-pair cables that are compliant with  
specifications on page 10, with RJ-45 plug connectors at both ends.  
Flashing LED (5 times/second) indicates All Ones detected on  
Link.  
2. Ensure that MDI/MDI-X switch is set according to network  
conditions.  
P(o)W(e)R Steady green LED indicates connection to external AC power.  
Using SNMP*  
3. Connect RJ-45 plug connector at one end of cable to media  
converter RJ-45 jack connector.  
Use SNMP at an attached terminal or at a remote location to:  
4. Connect RJ-45 plug connector at other end of cable to network  
equipment.  
Monitor media converter by monitoring:  
Media Converter Power  
Fiber Link Status  
FIBER  
1. Locate or build fiber cables that are compliant with specifications  
on page 9, with male two-stranded TX to RX connectors installed at  
both ends.  
Copper Link Status  
Hardware Switch settings  
AIS detected on Fiber  
TX  
TX  
AIS detected on Copper  
Enter network commands that:  
Enable/disable Loop-back on Fiber  
RX  
RX  
Enable/disable Transmit All Ones on Fiber when Copper is down  
Enable/disable Transmit All Ones on Copper when Fiber is down  
Power Down Media Converter.  
2. Connect cable with connector installed at TX location on media  
converter to RX location on attached device.  
3. Connect cable with connector installed at RX location on media  
*See the on-line documentation that comes with TRANSITION Networks  
FocalPoint software for applicable commands and usage.  
converter to TX location on attached device.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Telex Stereo Amplifier 811 100 User Manual
Thule Automobile Accessories 077 User Manual
Topcom Cordless Telephone ORBIT User Manual
Toshiba Personal Computer M505 User Manual
Toshiba Power Supply 300 KW User Manual
TP Link Network Card TL PA4020P User Manual
Traulsen Refrigerator UHT27 User Manual
TVS electronic Printer MSP 255 User Manual
Vulcan Hart Hot Beverage Maker ML 103414 User Manual
Waterpik Technologies Electric Toothbrush WP 440 User Manual