Trane Furnace TUD2B080A9V3VB User Manual

UPFLOW/HORIZONTAL  
2-STAGE, VARIABLE SPEED  
GAS-FIRED FURNACE  
XV80  
MODELS  
TUD2B060A9V3VB, TUD2B080A9V3VB  
TUD2C080A9V4VB, TUD2C080B9V4VB  
TUD2B100A9V3VB, TUD2C100A9V5VB  
TUD2C100B9V5VB, TUD2D120A9V5VB  
TUD2D120B9V5VB, TUD2D140A9V5VB  
Two-Stage FanAssisted  
CombustionSystem  
PUB. NO. 22-1650-13  
© 2011 Trane  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
2
Feature Summary  
4
4
5
Features and Benefits  
Standard Equipment  
Optional Equipment  
6
General Data  
TUD2B060A9V3VB  
TUD2B080A9V3VB  
TUD2C080A9V4VB  
TUD2C080B9V4VB  
TUD2B100A9V3VB  
TUD2C100A9V5VB  
TUD2C100B9V5VB  
TUD2D120A9V5VB  
TUD2D120B9V5VB  
TUD2D140A9V5VB  
9
Performance Data  
Electric Data  
19  
19  
24  
Field Wiring Diagrams  
Dimensions  
3
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
and Benefits  
XV80 STANDARD EQUIPMENT  
• Upflow/Horizontal and  
• Power supply 115/1/60  
• 2-stage gas valve  
• Insulated blower door  
• Gasketed blower door  
• Internal filter rack  
• 2-speed venter  
• Standard filter sizes  
• Variable speed blower motor  
Two-tone color  
• Silicon Nitride hot surface igniter with  
• Direct drive, variable speed motor  
• Integrated solid state control with  
self-diagnostics  
• Common vent capability  
• Cleanable framed filters  
• Optional L.P. conversion kit  
• Left/right gas connection  
• Accessory hook-up capability  
adaptive heat up  
• Integrated solid state control  
• Attractive color accents  
• Heavy gauge aluminized steel heat  
exchanger  
• Multi-port In-shot burners  
• Complete front service access  
• Alternate bottom/left/right return air  
• Slide out blower assembly  
• Hinged blower door  
• Selectable cooling fan off delay  
eliminates need for BAY24X045 time  
delay kit  
• Perfect fit door catches  
• Enhanced cooling control  
22-1650-13  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
and Benefits  
XV80 OPTIONAL EQUIPMENT  
Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling ........................................................................................TAYSTAT241 [  
Thermostat, Mechanical Heating Only With Fan Switch............................................................................................. BAYSTAT303 [  
Thermostat, Mechanical Heating Only ....................................................................................................................... BAYSTAT388 [  
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................AY28X092 [  
Thermostat, Electronic Non-programmable 1-Stage Heating/1-Stage Cooling.......................................................... BAYSTAT370 [  
Thermostat, Electronic Programmable (5-2) 1-Stage Heating/1-Stage Cooling......................................................... BAYSTAT340 [  
Thermostat, Heating/Cooling Single Stage (Mounts Vertically).................................................................................. BAYSTAT305 [  
Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling ............................................................... TAYSTAT302C [  
Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ............................................................... TAYSTAT300C [  
Propane Conversion Kit........................................................................................................................................... BAYLPKT210A [  
Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace)........................................................TFM175A9FR0 [  
Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace)..............................................................TFM210A9FR0 [  
Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace)........................................................TFM245A9FR0 [  
Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace)..................................................TFP175A9FR0 [  
Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace)........................................................TFP210A9FR0 [  
Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace)..................................................TFP245A9FR0 [  
Coil Enclosure (17-1/2" Wide Cabinets) ............................................................................................................BAYCLE17A1722A [  
Coil Enclosure (21" Wide Cabinets) ..................................................................................................................BAYCLE21A2130A [  
Coil Enclosure (24-1/2" Wide Cabinets) ............................................................................................................BAYCLE24A2430A [  
Side Filter Rack .......................................................................................................................................................... BAYFLTR200 [  
High Altitude Switch....................................................................................................................................................BAYHALT249 [  
Masonry Chimney Vent Kit (Upflow models only)....................................................................................................BAYVENT800B [  
Filter Rack Kit 1 .................................................................................................................................................... BAYRACK960A [  
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
1 Available for models with 1800 CFM or greater which require an additional side return.  
22-1650-13  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL DATA  
TUD-R9V PRODUCT SPECIFICATIONS1  
MODEL  
TUD2B060A9V3VB  
TUD2B080A9V3VB  
TUD2C080A9V4VB  
TYPE  
Upflow/Horizontal  
Upflow/Horizontal  
Upflow/Horizontal  
RATINGS 2  
1st Stage Input BTUH  
39,000  
31,200  
60,000  
48,000  
30 - 60  
52,000  
41,600  
80,000  
64,000  
30 - 60  
52,000  
41,600  
80,000  
64,000  
30 - 60  
1st Stage Capacity BTUH (ICS) 3  
2nd Stage Input BTUH  
2nd Stage Capacity BTUH (ICS) 3  
Temp. rise (Min.-Max.) °F.  
BLOWER DRIVE  
Diameter - Width (In.)  
No. Used  
Direct  
10 x 7  
Direct  
10 x 7  
Direct  
10 x 10  
1
1
1
Speeds (No.)  
CFM vs. in. w.g.  
Motor HP  
Variable  
See Airflow Table  
1/2  
Variable  
See Airflow Table  
1/2  
Variable  
See Airflow Table  
3/4  
R.P.M.  
Variable  
115/1/60  
Variable  
115/1/60  
Variable  
115/1/60  
Volts/Ph/Hz  
COMBUSTION FAN -Type  
Drive - No. Speeds  
Motor HP - RPM  
Volts/Ph/Hz  
Centrifugal  
Direct - 2  
1/50 - 3000  
115/1/60  
0.7  
Centrifugal  
Direct - 2  
1/50 - 3000  
115/1/60  
0.7  
Centrifugal  
Direct - 2  
1/50 - 3000  
115/1/60  
0.7  
FLA  
FILTER — Furnished?  
Type Recommended  
Hi Vel. (No.-Size-Thk.)  
Ye s  
Ye s  
Ye s  
High Velocity  
1 - 17x25 - 1in.  
High Velocity  
1 - 17x25 - 1in.  
High Velocity  
1 - 20x25 - 1in.  
VENT — Size (In.)  
4 Round  
4 Round  
4 Round  
HEAT EXCHANGER  
Type -Fired  
Alum. Steel - Type 1  
20  
Alum. Steel - Type 1  
20  
Alum. Steel - Type 1  
20  
-Unfired  
Gauge (Fired)  
ORIFICES — Main  
Nat. Gas. Qty. — Drill Size  
L.P. Gas Qty. — Drill Size  
3 — 45  
3 — 56  
4 — 45  
4 — 56  
4 — 45  
4 — 56  
GAS VALVE  
Redundant - Two Stage  
Redundant - Two Stage  
Redundant - Two Stage  
PILOT SAFETY DEVICE  
Type  
Hot Surface Ignition  
Hot Surface Ignition  
Hot Surface Ignition  
BURNERS Type  
Multi-port In-shot  
3
Multi-port In-shot  
4
Multi-port In-shot  
4
Number  
POWER CONN. — V/Ph/Hz 4  
Ampacity (In Amps)  
115/1/60  
10.5  
115/1/60  
10.5  
115/1/60  
12.9  
Max. Overcurrent Protection (Amps)  
15  
15  
20  
PIPE CONN. SIZE (In.)  
1/2  
1/2  
1/2  
DIMENSIONS  
H x W x D  
H x W x D  
H x W x D  
Crated (In.)  
41-3/4 x 19-1/2 x 30-1/2  
41-3/4 x 19-1/2 x 30-1/2  
41-3/4 x 23 x 30-1/2  
WEIGHT  
Shipping (Lbs.)/Net (Lbs.)  
136 / 126  
142 / 132  
166 / 155  
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3  
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,  
above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.  
3 Based on U.S. government standard tests.  
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.  
6
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TUD-R9V PRODUCT SPECIFICATIONS1  
MODEL  
TYPE  
TUD2C100A9V5VB  
TUD2C080B9V4VB 5  
TUD2B100A9V3VB  
Upflow/Horizontal  
Upflow/Horizontal  
Upflow/Horizontal  
RATINGS 2  
1st Stage Input BTUH  
65,000  
52,000  
100,000  
79,000  
35 - 65  
52,000  
41,600  
80,000  
64,000  
30 - 60  
65,000  
52,000  
100,000  
80,000  
40 - 70  
1st Stage Capacity BTUH (ICS) 3  
2nd Stage Input BTUH  
2nd Stage Capacity BTUH (ICS) 3  
Temp. rise (Min.-Max.) °F.  
BLOWER DRIVE  
Diameter - Width (In.)  
No. Used  
Direct  
10 x 10  
1
Direct  
10 x 10  
Direct  
10 x 7  
1
1
Speeds (No.)  
CFM vs. in. w.g.  
Motor HP  
Variable  
See Airflow Table  
1
Variable  
See Airflow Table  
3/4  
Variable  
See Airflow Table  
1/2  
R.P.M.  
Variable  
115/1/60  
Variable  
115/1/60  
Variable  
115/1/60  
Volts/Ph/Hz  
COMBUSTION FAN -Type  
Drive - No. Speeds  
Motor HP - RPM  
Volts/Ph/Hz  
Centrifugal  
Direct - 2  
1/50 - 3000  
115/1/60  
0.87  
Centrifugal  
Direct - 2  
1/50 - 3000  
115/1/60  
0.7  
Centrifugal  
Direct - 2  
1/50 - 3000  
115/1/60  
0.87  
FLA  
FILTER — Furnished?  
Type Recommended  
Hi Vel. (No.-Size-Thk.)  
Ye s  
Ye s  
Ye s  
High Velocity  
1 - 20x25 - 1in.  
High Velocity  
1 - 20x25 - 1in.  
High Velocity  
1 - 17x25 - 1in.  
VENT — Size (In.)  
4 Round  
4 Round  
4 Round  
HEAT EXCHANGER  
Type -Fired  
Alum. Steel - Type 1  
20  
Alum. Steel - Type 1  
20  
Alum. Steel - Type 1  
20  
-Unfired  
Gauge (Fired)  
ORIFICES — Main  
Nat. Gas. Qty. — Drill Size  
L.P. Gas Qty. — Drill Size  
5 — 45  
5 — 56  
4 — 45  
4 — 56  
5 — 45  
5 — 56  
GAS VALVE  
Redundant - Two Stage  
Redundant - Two Stage  
Redundant - Two Stage  
PILOT SAFETY DEVICE  
Type  
Hot Surface Ignition  
Hot Surface Ignition  
Hot Surface Ignition  
BURNERS Type  
Multi-port In-shot  
5
Multi-port In-shot  
4
Multi-port In-shot  
5
Number  
POWER CONN. — V/Ph/Hz 4  
Ampacity (In Amps)  
115/1/60  
14.9  
115/1/60  
12.9  
115/1/60  
10.8  
Max. Overcurrent Protection (Amps)  
20  
20  
15  
PIPE CONN. SIZE (In.)  
1/2  
1/2  
1/2  
DIMENSIONS  
H x W x D  
H x W x D  
H x W x D  
Crated (In.)  
41-3/4 x 23 x 30-1/2  
41-3/4 x 23 x 30-1/2  
41-3/4 x 19-1/2 x 30-1/2  
WEIGHT  
Shipping (Lbs.)/Net (Lbs.)  
166 / 155  
166 / 155  
142 / 132  
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3  
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,  
above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.  
3 Based on U.S. government standard tests.  
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.  
5 Model uses high efficiency blower.  
22-1650-13  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
TUD-R9V PRODUCT SPECIFICATIONS1  
MODEL  
TYPE  
TUD2D140A9V5VB  
TUD2C100B9V5VB 5  
TUD2D120A9V5VB  
TUD2D120B9V5VB 5  
Upflow/Horizontal  
Upflow/Horizontal  
Upflow/Horizontal  
Upflow/Horizontal  
RATINGS 2  
1st Stage Input BTUH  
91,000  
72,800  
140,000  
111,000  
40 - 70  
65,000  
52,000  
100,000  
79,000  
35 - 65  
78,000  
62,400  
120,000  
97,000  
35 - 65  
78,000  
62,400  
120,000  
97,000  
35 - 65  
1st Stage Capacity BTUH (ICS) 3  
2nd Stage Input BTUH  
2nd Stage Capacity BTUH (ICS) 3  
Temp. rise (Min.-Max.) °F.  
BLOWER DRIVE  
Diameter - Width (In.)  
No. Used  
Direct  
10 x 10  
1
Direct  
10 x 10  
1
Direct  
10 x 10  
1
Direct  
10 x 10  
1
Speeds (No.)  
CFM vs. in. w.g.  
Motor HP  
Variable  
See Airflow Table  
1
Variable  
See Airflow Table  
1
Variable  
See Airflow Table  
1
Variable  
See Airflow Table  
1
R.P.M.  
Variable  
115/1/60  
Variable  
115/1/60  
Variable  
115/1/60  
Variable  
115/1/60  
Volts/Ph/Hz  
COMBUSTION FAN -Type  
Drive - No. Speeds  
Motor HP - RPM  
Volts/Ph/Hz  
Centrifugal  
Direct - 2  
1/50 - 3000  
115/1/60  
1.16  
Centrifugal  
Direct - 2  
1/50 - 3000  
115/1/60  
0.87  
Centrifugal  
Direct - 2  
1/50 - 3000  
115/1/60  
1.14  
Centrifugal  
Direct - 2  
1/50 - 3000  
115/1/60  
1.14  
FLA  
FILTER — Furnished?  
Type Recommended  
Hi Vel. (No.-Size-Thk.)  
Ye s  
Ye s  
Ye s  
Ye s  
High Velocity  
1 - 24x25 - 1in.  
High Velocity  
1 - 20x25 - 1in.  
High Velocity  
1 - 24x25 - 1in.  
High Velocity  
1 - 24x25 - 1in.  
VENT — Size (In.)  
4 Round  
4 Round  
4 Round  
4 Round  
HEAT EXCHANGER  
Type -Fired  
Alum. Steel - Type 1  
20  
Alum. Steel - Type 1  
20  
Alum. Steel - Type 1  
20  
Alum. Steel - Type 1  
20  
-Unfired  
Gauge (Fired)  
ORIFICES — Main  
Nat. Gas. Qty. — Drill Size  
L.P. Gas Qty. — Drill Size  
7 — 45  
7 — 56  
5 — 45  
5 — 56  
6 — 45  
6 — 56  
6 — 45  
6 — 56  
GAS VALVE  
Redundant - Two Stage  
Redundant - Two Stage  
Redundant - Two Stage  
Redundant - Two Stage  
PILOT SAFETY DEVICE  
Type  
Hot Surface Ignition  
Hot Surface Ignition  
Hot Surface Ignition  
Hot Surface Ignition  
BURNERS Type  
Multi-port In-shot  
7
Multi-port In-shot  
5
Multi-port In-shot  
6
Multi-port In-shot  
6
Number  
POWER CONN. — V/Ph/Hz 4  
Ampacity (In Amps)  
115/1/60  
15.3  
115/1/60  
14.9  
115/1/60  
15.3  
115/1/60  
15.3  
Max. Overcurrent Protection (Amps)  
20  
20  
20  
20  
PIPE CONN. SIZE (In.)  
1/2  
1/2  
1/2  
1/2  
DIMENSIONS  
H x W x D  
H x W x D  
H x W x D  
H x W x D  
Crated (In.)  
41-3/4 x 26-1/2 x 30-1/2  
41-3/4 x 23 x 30-1/2  
41-3/4 x 26-1/2 x 30-1/2  
41-3/4 x 26-1/2 x 30-1/2  
WEIGHT  
Shipping (Lbs.)/Net (Lbs.)  
197 / 185  
166 / 155  
193 / 181  
193 / 181  
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3  
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,  
above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.  
3 Based on U.S. government standard tests.  
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.  
5 Model uses high efficiency blower.  
8
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UD2B060A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW7  
SW8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
589  
49  
65  
604  
48  
95  
619  
47  
125  
604  
48  
160  
607  
48  
200  
LOW  
MEDIUM **  
HIGH  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
663  
44  
75  
694  
42  
120  
684  
42  
145  
681  
42  
185  
686  
42  
220  
ON  
OFF  
ON  
OFF  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
775  
37  
105  
781  
37  
145  
776  
37  
180  
805  
36  
230  
811  
36  
270  
CFM  
TEMP. RISE  
WATTS  
813  
55  
110  
818  
54  
150  
818  
54  
185  
837  
53  
240  
842  
53  
280  
LOW  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
907  
49  
140  
919  
48  
200  
942  
47  
240  
958  
46  
300  
959  
46  
330  
MEDIUM **  
HIGH  
ON  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1038  
43  
190  
1066  
42  
260  
1086  
41  
325  
1089  
41  
365  
1079  
41  
415  
OFF  
*UD2B060A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW1  
ON  
SW2  
ON  
SW3  
OFF  
SW4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/ TON)  
CFM  
WATTS  
499  
50  
537  
80  
520  
110  
520  
145  
500  
175  
NORMAL  
(400 CFM/ TON)  
CFM  
WATTS  
605  
60  
610  
80  
610  
120  
597  
155  
593  
180  
1.5  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/ TON)  
CFM  
WATTS  
649  
75  
681  
110  
665  
145  
665  
180  
672  
220  
LOW  
(350 CFM/ TON)  
CFM  
WATTS  
680  
80  
722  
125  
680  
150  
696  
190  
696  
225  
OFF  
OFF  
OFF  
OFF  
NORMAL  
(400 CFM/ TON)  
CFM  
WATTS  
798  
105  
804  
145  
809  
170  
823  
235  
818  
280  
OFF  
2
HIGH  
(450 CFM/ TON)  
CFM  
WATTS  
884  
145  
896  
180  
924  
240  
931  
280  
931  
330  
OFF  
ON  
ON  
OFF  
LOW  
(350 CFM/ TON)  
CFM  
WATTS  
858  
125  
863  
175  
882  
220  
894  
275  
895  
320  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/ TON)  
CFM  
WATTS  
984  
170  
1017  
225  
1038  
295  
1017  
330  
1017  
375  
2.5  
HIGH  
(450 CFM/ TON)  
CFM  
WATTS  
1125  
245  
1138  
315  
1150  
370  
1161  
435  
1161  
475  
ON  
LOW  
(350 CFM/ TON)  
CFM  
WATTS  
1035  
205  
1056  
265  
1076  
330  
1076  
370  
1076  
430  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL **  
(400 CFM/ TON)  
CFM  
WATTS  
1208  
300  
1247  
360  
1268  
440  
1278  
485  
1200  
490  
3 **  
OFF  
OFF  
HIGH  
(450 CFM/ TON)  
CFM  
WATTS  
1380  
440  
1410  
500  
1402  
550  
1350  
550  
1235  
525  
NOTES:  
1. *FIRST LETTER MAY BE "A" OR "T"  
2. **FACTORY SETTING.  
3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.  
4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING:  
NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.  
22-1650-13  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UD2B080A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
800  
48  
100  
790  
49  
135  
765  
50  
155  
750  
52  
200  
730  
53  
230  
LOW  
MEDIUM **  
HIGH  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
910  
43  
130  
890  
44  
170  
875  
44  
210  
860  
45  
240  
820  
47  
280  
ON  
OFF  
ON  
OFF  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1060  
37  
188  
1020  
38  
220  
1010  
39  
265  
1010  
39  
310  
1000  
39  
350  
CFM  
TEMP. RISE  
WATTS  
1110  
54  
210  
1090  
55  
260  
1090  
55  
310  
1080  
55  
350  
1065  
56  
400  
LOW  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1245  
48  
300  
1240  
48  
355  
1240  
48  
410  
1230  
48  
460  
1215  
49  
500  
MEDIUM **  
ON  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1415  
42  
410  
1400  
42  
470  
1400  
42  
530  
1375  
43  
580  
1320  
45  
590  
HIGH  
OFF  
*UD2B080A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
OFF  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
880  
120  
875  
155  
860  
190  
845  
225  
840  
245  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1020  
170  
1000  
205  
990  
240  
980  
280  
960  
320  
2.5  
3.0  
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1110  
210  
110  
260  
1110  
320  
1100  
350  
1100  
385  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1040  
190  
1010  
220  
1000  
260  
1000  
310  
990  
340  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1200  
250  
1200  
320  
1190  
370  
1190  
415  
1175  
450  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1340  
355  
1340  
425  
1330  
475  
1320  
530  
1300  
570  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1215  
265  
1210  
330  
1210  
375  
1200  
430  
1185  
465  
OFF  
OFF  
NORMAL **  
(400 CFM/TON)  
CFM  
WATTS  
1430  
415  
1415  
457  
1410  
520  
1385  
575  
1330  
580  
3.5 **  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1430  
415  
1415  
475  
1410  
520  
1385  
575  
1330  
580  
NOTES:  
1. * First Letter may be "A" or "T"  
2. ** Factory setting  
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.  
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;  
HIGH 450 cfm/ton is for DRY CLIMATE setting  
10  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UD2C080A9V4VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
782  
49  
75  
762  
51  
110  
751  
51  
145  
748  
51  
185  
737  
52  
225  
LOW  
MEDIUM **  
HIGH  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
870  
44  
90  
865  
45  
125  
861  
45  
175  
848  
45  
215  
831  
46  
255  
ON  
OFF  
ON  
OFF  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
962  
40  
110  
974  
40  
155  
963  
40  
200  
938  
41  
245  
914  
42  
290  
CFM  
TEMP. RISE  
WATTS  
1091  
54  
145  
1092  
54  
190  
1087  
55  
245  
1092  
54  
305  
1077  
55  
355  
LOW  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1211  
49  
190  
1243  
48  
255  
1243  
48  
310  
1244  
48  
370  
1235  
48  
430  
MEDIUM **  
HIGH  
ON  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1371  
43  
255  
1388  
43  
325  
1392  
43  
395  
1385  
43  
455  
1377  
43  
515  
OFF  
*UD2C080A9V4VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
863  
90  
865  
130  
858  
175  
843  
220  
831  
255  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
995  
115  
1005  
170  
989  
210  
973  
260  
956  
305  
2.5  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1101  
150  
1112  
200  
1111  
255  
1107  
305  
1101  
360  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1031  
125  
1031  
175  
1026  
215  
1013  
270  
1003  
320  
OFF  
OFF  
OFF  
OFF  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1163  
170  
1178  
230  
1188  
285  
1183  
345  
1178  
405  
OFF  
3.0  
3.5  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1319  
240  
1337  
305  
1344  
365  
1340  
420  
1336  
485  
OFF  
ON  
ON  
OFF  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1182  
200  
1206  
240  
1211  
295  
1211  
350  
1211  
420  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1380  
255  
1401  
325  
1402  
390  
1402  
460  
1399  
515  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1553  
350  
1566  
425  
1557  
500  
1558  
560  
1559  
645  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1386  
255  
1401  
330  
1408  
395  
1402  
460  
1390  
520  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL **  
(400 CFM/TON)  
CFM  
WATTS  
1590  
360  
1593  
440  
1591  
515  
1588  
575  
1576  
650  
4 **  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1791  
360  
1808  
615  
1810  
615  
1808  
775  
1726  
800  
NOTES:  
1. * First Letter may be "A" or "T"  
2. ** Factory setting  
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.  
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;  
HIGH 450 cfm/ton is for DRY CLIMATE setting  
22-1650-13  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UD2C080B9V4VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
974  
49  
133  
968  
49  
285  
949  
50  
202  
925  
51  
254  
906  
52  
304  
LOW  
MEDIUM **  
HIGH  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1102  
43  
93  
1112  
43  
144  
1103  
43  
201  
1083  
44  
255  
1066  
45  
305  
ON  
OFF  
ON  
OFF  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1194  
40  
119  
1217  
39  
180  
1215  
39  
243  
1200  
40  
304  
1182  
40  
362  
CFM  
TEMP. RISE  
WATTS  
1189  
58  
142  
1210  
57  
209  
1209  
57  
276  
1193  
58  
341  
1175  
58  
404  
LOW  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1346  
51  
141  
1388  
49  
207  
1398  
49  
274  
1390  
49  
339  
1372  
50  
401  
MEDIUM **  
HIGH  
ON  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1460  
47  
186  
1516  
45  
263  
1536  
45  
335  
1533  
45  
407  
1515  
45  
477  
OFF  
*UD2C080B9V4VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
842  
71  
819  
114  
789  
163  
756  
207  
740  
249  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
956  
90  
948  
140  
928  
196  
901  
248  
884  
298  
2.5  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1071  
113  
1078  
171  
1067  
233  
1045  
292  
1028  
348  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1002  
99  
1000  
152  
983  
210  
958  
265  
942  
318  
OFF  
OFF  
OFF  
OFF  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1140  
128  
1155  
191  
1150  
256  
1132  
319  
1114  
379  
OFF  
3.0  
3.5  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1278  
165  
1311  
238  
1316  
308  
1305  
377  
1287  
444  
OFF  
ON  
ON  
OFF  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1163  
134  
1181  
199  
1177  
265  
1161  
328  
1143  
389  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1324  
179  
1363  
255  
1372  
326  
1363  
397  
1345  
466  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1485  
234  
1544  
319  
1566  
396  
1565  
472  
1546  
550  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1324  
179  
1363  
255  
1372  
326  
1363  
397  
1345  
466  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL **  
(400 CFM/TON)  
CFM  
WATTS  
1508  
243  
1570  
329  
1594  
407  
1593  
483  
1575  
562  
4 **  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1691  
322  
1777  
416  
1816  
499  
1824  
579  
1805  
669  
NOTES:  
1. * First Letter may be "A" or "T"  
2. ** Factory setting  
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.  
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;  
HIGH 450 cfm/ton is for DRY CLIMATE setting  
12  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UD2B100A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
751  
64  
86  
796  
61  
132  
817  
59  
175  
832  
58  
218  
838  
57  
263  
LOW  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
862  
56  
121  
921  
52  
185  
953  
51  
233  
967  
50  
285  
954  
50  
322  
MEDIUM **  
ON  
OFF  
CFM  
TEMP. RISE  
WATTS  
959  
50  
148  
1002  
48  
210  
1036  
46  
280  
1036  
46  
325  
1003  
48  
355  
HIGH  
LOW  
OFF  
ON  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1099  
67  
227  
1124  
66  
287  
1149  
64  
355  
1157  
64  
415  
1055  
70  
395  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1286  
58  
365  
1321  
56  
450  
1313  
56  
455  
1215  
61  
475  
1119  
66  
450  
MEDIUM **  
HIGH  
ON  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1399  
53  
465  
1419  
52  
570  
1347  
55  
545  
1265  
59  
520  
1163  
64  
485  
OFF  
*UD2B100A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
516  
50  
536  
75  
551  
105  
547  
135  
530  
165  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
583  
59  
615  
92  
633  
127  
621  
157  
618  
18  
1.5  
2.0  
2.5  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
681  
70  
697  
110  
701  
140  
709  
180  
712  
215  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
680  
75  
726  
120  
735  
150  
741  
190  
745  
230  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
769  
103  
819  
145  
843  
190  
858  
235  
865  
286  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
882  
130  
938  
190  
961  
245  
975  
300  
970  
345  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
831  
180  
903  
180  
928  
230  
935  
275  
935  
320  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
979  
167  
1036  
240  
1053  
295  
1053  
345  
1015  
368  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1121  
245  
1147  
310  
1176  
383  
1167  
442  
1055  
396  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1061  
210  
1081  
265  
1095  
320  
1101  
382  
1032  
380  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL **  
(400 CFM/TON)  
CFM  
WATTS  
1185  
278  
1223  
364  
1251  
435  
1205  
455  
1101  
426  
3.0**  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1351  
425  
1372  
503  
1343  
535  
1248  
505  
1168  
480  
NOTES:  
1. * First Letter may be "A" or "T"  
2. ** Factory setting  
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.  
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;  
HIGH 450 cfm/ton is for DRY CLIMATE setting  
22-1650-13  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UD2C100A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
900  
53  
100  
890  
54  
130  
870  
55  
175  
850  
57  
220  
835  
58  
270  
LOW  
MEDIUM **  
HIGH  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1125  
43  
150  
1090  
44  
200  
1060  
46  
235  
1070  
45  
300  
1070  
45  
340  
ON  
OFF  
ON  
OFF  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1300  
37  
220  
1300  
37  
290  
1320  
36  
365  
1350  
36  
430  
1340  
36  
490  
CFM  
TEMP. RISE  
WATTS  
1270  
59  
200  
1290  
58  
260  
1290  
58  
335  
1290  
58  
400  
1280  
58  
460  
LOW  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1575  
47  
355  
1600  
46  
445  
1610  
46  
520  
1600  
46  
575  
1580  
47  
650  
MEDIUM **  
HIGH  
ON  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1870  
40  
560  
1890  
39  
665  
1860  
40  
710  
1870  
40  
830  
1730  
43  
760  
OFF  
*UD2C100A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1075  
135  
1055  
185  
1015  
220  
1000  
265  
990  
325  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1220  
185  
1200  
240  
1210  
295  
1210  
350  
1210  
410  
3.0  
3.5  
4.0  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1390  
245  
1390  
320  
1410  
391  
1410  
470  
1400  
510  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1214  
185  
1210  
240  
1215  
295  
1210  
350  
1210  
415  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1430  
310  
1460  
355  
1470  
430  
1460  
500  
1440  
555  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1640  
370  
1665  
460  
1650  
540  
1640  
615  
1610  
660  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1405  
270  
1430  
310  
1440  
375  
1440  
480  
1420  
550  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1670  
395  
1675  
490  
1670  
550  
1655  
630  
1630  
700  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1870  
540  
1880  
635  
1880  
730  
1845  
800  
1670  
640  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1775  
480  
1800  
580  
1820  
680  
1800  
750  
1680  
740  
OFF  
OFF  
OFF  
OFF  
NORMAL **  
(400 CFM/TON)  
CFM  
WATTS  
2065  
755  
2020  
840  
1945  
900  
1805  
880  
1623  
800  
OFF  
5.0 **  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
2310  
1000  
2100  
1000  
2100  
950  
1965  
890  
1800  
825  
OFF  
OFF  
ON  
OFF  
NOTES:  
1. * First letter may be "A" or "T"  
2. ** Factory setting  
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.  
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;  
HIGH 450 cfm/ton is for DRY CLIMATE setting  
14  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UD2C100B9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
953  
50  
93  
944  
50  
146  
936  
51  
193  
908  
52  
243  
887  
54  
292  
LOW  
MEDIUM **  
HIGH  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1142  
42  
135  
1141  
42  
200  
1135  
42  
255  
1112  
43  
322  
1098  
43  
377  
ON  
OFF  
ON  
OFF  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1258  
38  
169  
1260  
38  
240  
1256  
38  
302  
1236  
38  
378  
1227  
39  
437  
CFM  
TEMP. RISE  
WATTS  
1312  
52  
188  
1317  
52  
261  
1314  
52  
326  
1294  
53  
406  
1287  
53  
468  
LOW  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1577  
44  
301  
1592  
43  
387  
1592  
43  
468  
1597  
43  
563  
1582  
43  
644  
MEDIUM **  
HIGH  
ON  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1739  
39  
392  
1761  
39  
486  
1762  
39  
575  
1753  
39  
675  
1762  
39  
774  
OFF  
*UD2C100B9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1056  
114  
1050  
173  
1044  
225  
1019  
284  
1002  
336  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1199  
151  
1199  
219  
1194  
277  
1172  
349  
1161  
405  
3.0  
3.5  
4.0  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1342  
198  
1348  
273  
1345  
340  
1326  
422  
1320  
486  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1223  
158  
1224  
227  
1219  
287  
1198  
361  
1187  
418  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1389  
217  
1397  
294  
1395  
363  
1377  
449  
1373  
515  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1556  
291  
1570  
376  
1570  
455  
1556  
549  
1559  
629  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1389  
217  
1397  
294  
1395  
363  
1377  
449  
1373  
515  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1580  
303  
1595  
389  
1595  
469  
1582  
565  
1585  
647  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1770  
411  
1793  
507  
1795  
598  
1787  
698  
1797  
801  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1723  
382  
1744  
475  
1754  
564  
1735  
663  
1744  
760  
OFF  
OFF  
OFF  
OFF  
NORMAL **  
(400 CFM/TON)  
CFM  
WATTS  
1961  
546  
1991  
652  
1996  
751  
1991  
850  
2010  
981  
OFF  
5.0 **  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
2199  
754  
2217  
875  
2217  
983  
2197  
1067  
1987  
943  
OFF  
OFF  
ON  
OFF  
NOTES:  
1. * First letter may be "A" or "T"  
2. ** Factory setting  
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.  
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;  
HIGH 450 cfm/ton is for DRY CLIMATE setting  
22-1650-13  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UD2D120A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW7  
SW8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
1007  
57  
114  
1062  
54  
177  
1084  
53  
285  
1063  
54  
303  
1063  
54  
350  
LOW  
MEDIUM **  
HIGH  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1154  
50  
167  
1211  
48  
230  
1211  
48  
277  
1221  
47  
344  
1212  
48  
417  
ON  
OFF  
ON  
OFF  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1288  
45  
208  
1319  
44  
273  
1310  
44  
330  
1349  
43  
410  
1358  
43  
460  
CFM  
TEMP. RISE  
WATTS  
1387  
64  
250  
1421  
63  
320  
1455  
61  
400  
1488  
60  
460  
1495  
59  
540  
LOW  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1589  
56  
350  
1637  
54  
440  
1666  
53  
535  
1678  
53  
600  
1541  
58  
575  
MEDIUM **  
HIGH  
ON  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1771  
50  
475  
1788  
50  
560  
1804  
49  
650  
1751  
51  
675  
1554  
57  
590  
OFF  
*UD2D120A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
AIRFLOW  
SETTING  
(See Notes)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
SW1  
OFF  
SW2  
ON  
SW3  
OFF  
SW4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/ TON)  
CFM  
WATTS  
1195  
150  
1243  
225  
1235  
275  
1251  
325  
1251  
410  
NORMAL  
(400 CFM/ TON)  
CFM  
WATTS  
1353  
210  
1403  
290  
1417  
370  
1437  
425  
1458  
485  
3.5  
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/ TON)  
CFM  
WATTS  
1554  
315  
1572  
410  
1615  
480  
1634  
570  
1567  
575  
LOW  
(350 CFM/ TON)  
CFM  
WATTS  
1356  
200  
1391  
280  
1399  
370  
1433  
420  
1454  
510  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/ TON)  
CFM  
WATTS  
1565  
320  
1584  
410  
1633  
475  
1639  
560  
1554  
575  
4
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/ TON)  
CFM  
WATTS  
1766  
450  
1799  
550  
1810  
650  
1784  
685  
1590  
600  
ON  
LOW  
(350 CFM/ TON)  
CFM  
WATTS  
1708  
420  
1758  
530  
1759  
585  
1775  
675  
1575  
585  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL **  
(400 CFM/ TON)  
CFM  
WATTS  
1994  
665  
2018  
775  
1971  
785  
1814  
725  
1618  
625  
5 **  
OFF  
OFF  
HIGH  
(450 CFM/ TON)  
CFM  
WATTS  
2247  
975  
2152  
925  
2019  
860  
1861  
765  
1693  
680  
NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON".  
1. *FIRST LETTER MAY BE "A" OR "T"  
2. **FACTORY SETTING.  
3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.  
4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING:  
NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.  
16  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UD2D120B9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
S4-3  
S4-4  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
1050  
45  
99  
1044  
46  
146  
1035  
46  
208  
1005  
47  
252  
980  
48  
310  
LOW  
MEDIUM **  
HIGH  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1214  
39  
129  
1216  
39  
188  
1217  
39  
262  
1192  
40  
252  
1169  
41  
310  
ON  
OFF  
ON  
OFF  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1288  
37  
147  
1293  
37  
212  
1298  
37  
293  
1275  
37  
309  
1254  
38  
373  
CFM  
TEMP. RISE  
WATTS  
1429  
48  
191  
1440  
48  
267  
1453  
47  
363  
1435  
48  
340  
1416  
48  
406  
LOW  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1672  
41  
310  
1695  
40  
402  
1722  
40  
528  
1711  
40  
409  
1697  
40  
480  
MEDIUM **  
HIGH  
ON  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1782  
39  
385  
1809  
38  
480  
1890  
36  
623  
1835  
37  
565  
1871  
37  
644  
OFF  
*UD2D120B9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
AIRFLOW  
SETTING  
(See Notes)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
S3-1  
OFF  
S3-2  
ON  
S3-3  
OFF  
S3-4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/ TON)  
CFM  
WATTS  
1208  
128  
1209  
186  
1210  
260  
1185  
306  
1162  
370  
NORMAL  
(400 CFM/ TON)  
CFM  
WATTS  
1343  
162  
1350  
232  
1358  
318  
1337  
365  
1317  
433  
3.5  
4.0  
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/ TON)  
CFM  
WATTS  
1477  
210  
1491  
290  
1507  
391  
1490  
436  
1472  
508  
LOW  
(350 CFM/ TON)  
CFM  
WATTS  
1343  
162  
1350  
232  
1358  
318  
1337  
365  
1317  
433  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/ TON)  
CFM  
WATTS  
1496  
218  
1511  
300  
1528  
403  
1511  
447  
1494  
520  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/ TON)  
CFM  
WATTS  
1650  
296  
1671  
387  
1698  
511  
1686  
548  
1671  
626  
ON  
LOW  
(350 CFM/ TON)  
CFM  
WATTS  
1612  
274  
1631  
363  
1655  
482  
1642  
521  
1627  
598  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL **  
(400 CFM/ TON)  
CFM  
WATTS  
1858  
403  
1902  
533  
1907  
624  
1906  
714  
1871  
755  
5.0 **  
OFF  
OFF  
HIGH  
(450 CFM/ TON)  
CFM  
WATTS  
1871  
585  
2126  
711  
2110  
797  
2098  
888  
2001  
953  
NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON".  
1. *FIRST LETTER MAY BE "A" OR "T"  
2. **FACTORY SETTING.  
3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.  
4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING:  
NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.  
22-1650-13  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UD2D140A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
1090  
62  
130  
1100  
61  
175  
1070  
63  
215  
1080  
62  
255  
1060  
63  
290  
LOW  
MEDIUM **  
HIGH  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1230  
55  
180  
1265  
53  
235  
1280  
53  
315  
1300  
52  
380  
1300  
52  
455  
ON  
OFF  
ON  
OFF  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1380  
49  
235  
1405  
48  
290  
1425  
47  
375  
1430  
47  
415  
1450  
47  
520  
CFM  
TEMP. RISE  
WATTS  
1545  
67  
320  
1550  
67  
385  
1560  
67  
475  
1560  
67  
540  
1575  
66  
605  
LOW  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1760  
59  
435  
1790  
58  
545  
1810  
58  
620  
1800  
58  
695  
1725  
60  
725  
MEDIUM **  
HIGH  
ON  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
2000  
52  
615  
2010  
52  
715  
2000  
52  
790  
1950  
54  
820  
1800  
58  
775  
OFF  
*UD2D140A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
OFF  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1175  
165  
1165  
200  
1180  
265  
1170  
320  
1150  
400  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1345  
225  
1370  
285  
1400  
360  
1405  
440  
1380  
490  
3.5  
4.0  
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1525  
295  
1565  
390  
1585  
470  
1575  
515  
1530  
585  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1320  
220  
1330  
275  
1335  
355  
1300  
435  
1240  
490  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1550  
310  
1580  
400  
1590  
475  
1555  
540  
1460  
610  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1735  
430  
1735  
510  
1710  
600  
1670  
675  
1590  
710  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1700  
415  
1725  
470  
1730  
560  
1725  
640  
1690  
700  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL **  
(400 CFM/TON)  
CFM  
WATTS  
1980  
616  
1980  
710  
1950  
770  
1885  
780  
1735  
735  
5.0 **  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
2190  
835  
2150  
870  
2075  
890  
1905  
800  
1735  
735  
NOTES:  
1. * First Letter may be "A" or "T"  
2. ** Factory setting  
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.  
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;  
HIGH 450 cfm/ton is for DRY CLIMATE setting  
18  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT DATA  
WIRING DIAGRAM  
From Dwg. D344249P02  
22-1650-13  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT DATA  
SCHEMATIC DIAGRAMS  
From Dwg. D344249P02  
20  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT DATA  
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY  
TO 115 V 1 PH.,  
60 HZ., POWER  
SUPPLY PER  
LOCAL CODES  
M SEE  
HUM SEE  
NOTE 5  
EAC SEE  
NOTE 5  
SEE  
From Dwg. 21B341127 Rev. 0  
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING  
TO 115 V 1 PH.,  
60 HZ., POWER  
M SEE  
SUPPLY PER  
LOCAL CODES  
TE 5  
HUM SEE  
NOTE 5  
EAC SEE  
C SEE  
NOTE 5  
TE 5  
From Dwg. 21B341126 Rev. 0  
22-1650-13  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT DATA  
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING WITH SINGLE STAGE COOLING  
(OUTDOOR SECTION WITHOUT TRANSFORMER)  
From Dwg. 21B341125 Rev. 1  
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH SINGLE STAGE COOLING  
(OUTDOOR SECTION WITHOUT TRANSFORMER)  
From Dwg. 21B341124 Rev. 1  
22  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT DATA  
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH TWO STAGE COOLING  
(OUTDOOR SECTION WITHOUT TRANSFORMER)  
TO 115 V 1 PH.,  
60 HZ., POWER  
SEE  
SUPPLY PER  
LOCAL CODES  
5
HUM SEE  
WER6  
NOTE 5  
DES L  
EAC SEE  
NOTE 5  
From Dwg. 21B341128 Rev. 0  
22-1650-13  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT DATA  
24  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
22-1650-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22-1650-13  
DATA SUBJECT TO CHANGE WITHOUT NOTICE  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT DATA  
Since the manufacturer has a policy of continuous product  
andproductdataimprovement,itreservestherighttochange  
the design and specifications without notice.  
Technical Literature - Printed in U.S.A.  
Trane  
6200 Troup Highway  
Tyler, TX 75707  
Download from Www.Somanuals.com. All Manuals Search And Download.  

TDK Network Card HHM Series HHM2409 User Manual
Tiger PDAs Smartphones 71 008 User Manual
Timex Watch W273 EU1 355 095013 User Manual
Toshiba Power Supply VF PS1 User Manual
Tripp Lite Marine Battery RV1012UL User Manual
Tripp Lite Power Supply XL INT User Manual
Troy Bilt Lawn Mower Pony User Manual
Uniden Cordless Telephone EXT 1960 User Manual
Vincent Audio CD Player CD S6MK User Manual
Wagner SprayTech Paint Sprayer W 687 E User Manual