TDD-D-1
Upflow/Horizontal
Two-stage Condensing
Gas-Fired Furnace
XV 90
TUY060,080,100,120R9V
Variable Speed Blower
Variable Speed Inducer
PUB. NO. 22-1682-05-0802 (EN)
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Feature Summary
2
4
Features and Benefits
Standard Equipment
Optional Equipment
General Data
6
TUY060R9V3V
TUY080R9V3V
TUY100R9V4V
TUY120R9V5V
Performance Data
Electrical Data
FieldWiring
7
11
12
15
Dimensions
Pub. No. 22-1682-05-0802 (EN)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Features
and Benefits
XV 90 STANDARD EQUIPMENT
• HInged blower door
• Variable speed indoor blower
• Silicon Nitride Igniter with adaptive
heat up
• Perfect fit door latches
• Insulated blower door
• Gasketed blower door
• Variable speed induced draft blower
• Direct/Non-Direct vent option
• Fused 24 volt control circuit
• Manual reset burner safety switches
• Power supply 115/1/60
• Internal filter rack
• Standard filter sizes
• Two tone color
• Complete front service access
• Left/right gas connection
• Adjustable fan off times
• Cleanable high velocity filters
• Optional L.P conversion kit
• Selectable cooling fan off delay
eliminates need for BAY24X045
time delay kit
• Convertible to horizontal on left side
• 2-stage gas valve
• PVC venting-1 or 2 pipe option
• Accessory hook-up capability
• Integrated solid state control with
self-diagnostics
• Attractive color accents
• Lifetime limited primary heat
exchanger or secondary heat
exchanger warranty to original
owner (Residential use)
• 5 Year limited parts warranty
• Heavy gauge aluminized steel heat
exchanger
• Multi-port In-shot burners
4
Pub. No. 22-1682-05-0802 (EN)
Download from Www.Somanuals.com. All Manuals Search And Download.
Features
and Benefits
OPTIONAL EQUIPMENT
Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... TAYSTAT241 [
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................... AY28X092 [
Thermostat, Heating/Cooling Single Stage (MountsVertically) .................................................................................... BAYSTAT305 [
Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling .................................................................. TAYSTAT302C [
Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling .................................................................. TAYSTAT300C [
Propane Conversion Kit ......................................................................................................................................... BAYLPKT210A [
Electronic Air Filter, “Perfect Fit” Super Efficiency (14-1/2"Wide Gas Furnace) .........................................................TFE145A9FR0 [
Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2"Wide Gas Furnace) .........................................................TFE175A9FR0 [
Electronic Air Filter, “Perfect Fit”Super Efficiency (21"Wide Gas Furnace) ...............................................................TFE210A9FR0 [
Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2"Wide Gas Furnace) .........................................................TFE245A9FR0 [
Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2"Wide Gas Furnace) .......................................................... TFM145A9FR0 [
Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2"Wide Gas Furnace) .......................................................... TFM175A9FR0 [
Electronic Air Filter, “Perfect Fit” High Efficiency (21"Wide Gas Furnace) ................................................................ TFM210A9FR0 [
Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2"Wide Gas Furnace) .......................................................... TFM245A9FR0 [
Electronic Air Filter, “Perfect Fit”Standard Efficiency (14-1/2" Wide Gas Furnace) .....................................................TFP145A9FR0 [
Electronic Air Filter, “Perfect Fit”Standard Efficiency (17-1/2" Wide Gas Furnace) .....................................................TFP175A9FR0 [
Electronic Air Filter, “Perfect Fit”Standard Efficiency (21" Wide Gas Furnace) ..........................................................TFP210A9FR0 [
Electronic Air Filter, “Perfect Fit”Standard Efficiency (24-1/2" Wide Gas Furnace) .....................................................TFP245A9FR0 [
Coil Enclosure (14-1/2" Wide Cabinets) .................................................................................................................. BAYCLE1400C [
Coil Enclosure (17-1/2" Wide Cabinets) .................................................................................................................. BAYCLE1700C [
Coil Enclosure (21"Wide Cabinets) ........................................................................................................................ BAYCLE2100C [
Coil Enclosure (24-1/2" Wide Cabinets) .................................................................................................................. BAYCLE2400C [
Side Filter Rack ........................................................................................................................................................ BAYFLTR200 [
Filter Kit/Horizontal ConversionTUY060, 080-R......................................................................................................... BAYFLTR203 [
Filter Kit/Horizontal ConversionTUY100-R ................................................................................................................ BAYFLTR204 [
Filter Kit/Horizontal ConversionTUY120-R ................................................................................................................ BAYFLTR205 [
Filter Accessory Kit Upflow 14.5" Furnaces ............................................................................................................... BAYFLTR317 [
Filter Accessory Kit Upflow 21" Furnaces .................................................................................................................. BAYFLTR321 [
Filter Accessory Kit Upflow 24.5" Furnaces ............................................................................................................... BAYFLTR324 [
High Altitude SwitchTUY060R .............................................................................................................................. BAYHALT2451 [
High Altitude SwitchTUY080, 100R ...................................................................................................................... BAYHALT2461 [
High Altitude SwitchTUY120R .............................................................................................................................. BAYHALT2471 [
ConcentricVent Kit ............................................................................................................................................... BAYVENT100A [
SidewallVentTermination Kit ................................................................................................................................. BAYVENT200B [
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
Manufactured/Mobile Home Kit............................................................................................................................. BAYMFGH100A [
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.
Pub. No. 22-1682-05-0802 (EN)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
TUY-R9V PRODUCT SPECIFICATIONS1
MODEL
TUY060R9V3V
TUY080R9V3V
TUY100R9V4V
TUY120R9V5V
RATINGS2
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS)
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)
AFUE (ICS)
39000
37000
60000
56000
93.0
52000
49000
80000
73000
92.5
65000
62000
100000
93000
93.0
78000
74000
120000
112000
92.5
3
3
Temp. Rise (Min.-Max.) °F.
35 - 65
35 - 65
35 - 65
40 - 70
BLOWER DRIVE
Dia.-Width (In.)
No.Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
DIRECT
10 x 8
1
VARIABLE
SEE FAN PERF.TABLE
1/2
DIRECT
10 x 8
1
VARIABLE
SEE FAN PERF.TABLE
1/2
DIRECT
10 x 10
1
VARIABLE
SEE FAN PERF.TABLE
1
DIRECT
10 x 10
1
VARIABLE
SEE FAN PERF.TABLE
1
R.P.M.
Volts/Ph/Hz
VARIABLE
115/1/60
VARIABLE
115/1/60
VARIABLE
115/1/60
VARIABLE
115/1/60
COMBUSTION FAN -TYPE
Drive - No. Speeds
Motor HP - RPM
Volts/Ph/Hz
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
CENTRIFUGAL
DIRECT - VARIABLE
1/25 - 5000
115/1/60
1.1
115/1/60
1.1
115/1/60
1.1
115/1/60
1.1
FL Amps
FILTER — Furnished?
Type Recommended
Filter (No.-Size-Thk.)
YES
HIGHVELOCITY
1 X 17 X 25 X 1
YES
HIGHVELOCITY
1 X 17 X 25 X 1
YES
HIGHVELOCITY
1 - 20 X 25 X 1
YES
HIGHVELOCITY
1 - 24 X 25 X 1
VENT — Size (In.)
2 ROUND
2 ROUND
3 ROUND
3 ROUND
HEAT EXCHANGER
Type-Fired
-Unfired
Gauge (Fired)
ALUMINIZED STEEL TYPE 1
20
ALUMINIZED STEEL TYPE 1
20
ALUMINIZED STEEL TYPE 1
20
ALUMINIZED STEELTYPE 1
20
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
3 - 45
3 - 56
4 - 45
4 - 56
5 - 45
5 - 56
6 - 45
6 - 56
GAS VALVE
REDUNDANT - TWO STAGE
REDUNDANT - TWO STAGE
REDUNDANT - TWO STAGE
REDUNDANT - TWO STAGE
DIRECT IGNITION DEVICE
Type
HOT SURFACE IGNITER
HOT SURFACE IGNITER
HOT SURFACE IGNITER
HOT SURFACE IGNITER
BURNERS —Type
Number
IN-SHOT
3
IN-SHOT
4
IN-SHOT
5
IN-SHOT
6
POWER CONN. —V/Ph/Hz
Ampacity (In Amps)
4
115/1/60
8.4
115/1/60
8.4
115/1/60
11.4
115/1/60
11.4
Max.Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
15
15
15
15
0.50
0.50
0.50
0.50
SEE OUTLINE DRAWING
SEE OUTLINE DRAWING
SEE OUTLINE DRAWING
SEE OUTLINE DRAWING
DIMENSIONS
Crated (In.)
Uncrated
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 23 X 30-1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 26-1/2 X 30-1/2
SEE OUTLINE DRAWING
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
158/146
158/148
171/160
205/193
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above
input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
6
Pub. No. 22-1682-05-0802 (EN)
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
*UY060R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 1
ON
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
-
LOW
(350 CFM/TON)
CFM
WATTS
575
65
575
90
575
125
550
155
NORMAL
(400 CFM/TON)
CFM
WATTS
640
70
640
110
640
140
630
175
1.5
2.0
2.5
3
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
-
-
-
-
-
-
HIGH
(450 CFM/TON)
CFM
WATTS
700
85
700
125
700
160
700
200
LOW
(350 CFM/TON)
CFM
WATTS
700
100
700
130
700
170
700
210
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
800
115
800
155
800
200
800
250
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
900
140
900
195
900
240
900
290
ON
LOW
(350 CFM/TON)
CFM
WATTS
875
130
875
180
875
230
875
270
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1000
175
1000
235
1000
285
1000
335
900
310
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1125
235
1125
295
1125
345
1100
370
925
318
ON
LOW
(350 CFM/TON)
CFM
WATTS
1050
195
1050
260
1050
305
1050
350
920
315
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1200
275
1200
330
1200
385
1100
385
940
330
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1325
360
1325
425
1300
460
1175
425
1000
365
NOTES: * First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
*UY060R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity =
2nd Stage Capacity =
37,000
56,000
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
-
CFM
TEMP. RISE
WATTS
600
57
85
600
57
110
600
57
155
600
57
190
LOW
MEDIUM LOW
NORMAL **
HIGH
ON
ON
CFM
TEMP. RISE
WATTS
700
49
90
700
49
130
700
49
175
700
49
210
OFF
ON
ON
OFF
OFF
ON
-
-
-
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
775
44
105
775
44
155
775
44
195
775
44
240
CFM
TEMP. RISE
WATTS
870
39
135
870
39
185
870
39
235
870
39
290
OFF
ON
CFM
TEMP. RISE
WATTS
860
61
140
920
57
200
920
57
245
920
57
300
670
79
245
LOW
CFM
TEMP. RISE
WATTS
1000
53
190
1000
53
255
1000
53
305
1000
53
340
700
75
255
MEDIUM LOW
NORMAL **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
1125
47
250
1125
47
315
1125
47
370
1025
51
355
775
68
285
OFF
OFF
CFM
TEMP. RISE
WATTS
1250
42
340
1250
42
405
1250
42
445
1100
48
390
1000
53
355
OFF
NOTES:
* First letter may be "A" or "T"
** Factory setting
Pub. No. 22-1682-05-0802 (EN)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
AIRFLOW
SETTING
(See Notes)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
SW 1
ON
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
750
84
750
122
750
154
720
185
710
221
NORMAL
(400 CFM/TON)
CFM
WATTS
840
109
840
146
840
181
840
226
820
264
2.0
2.5
3.0
3.5
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
940
136
940
177
940
215
940
274
940
318
LOW
(350 CFM/TON)
CFM
WATTS
850
113
850
150
870
200
890
250
890
295
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
960
150
990
200
1000
230
1020
305
1010
350
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1080
195
1110
255
1120
315
1120
365
1080
390
ON
LOW
(350 CFM/TON)
CFM
WATTS
1020
175
1020
225
1040
280
1050
330
1050
375
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1170
240
1180
300
1200
365
1200
415
1130
420
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1290
310
1320
410
1350
470
1340
520
1150
440
ON
LOW
(350 CFM/TON)
CFM
WATTS
1170
250
1190
315
1210
370
1210
435
1100
405
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1360
365
1390
445
1400
500
1360
535
1210
475
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1360
355
1390
450
1400
520
1350
535
1180
460
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
TUY080R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity =
2nd Stage Capacity =
49,000
73,000
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
800
56
105
800
56
140
800
56
180
800
56
220
800
56
265
LOW
MEDIUM LOW
NORMAL **
HIGH
ON
ON
CFM
TEMP. RISE
WATTS
860
52
115
880
51
165
890
50
215
920
48
265
910
49
320
OFF
ON
ON
OFF
OFF
ON
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
960
46
150
990
45
200
1000
44
230
1020
44
310
1010
44
350
CFM
TEMP. RISE
WATTS
1080
41
195
1110
40
255
1120
40
315
1120
40
365
1080
41
390
OFF
ON
CFM
TEMP. RISE
WATTS
1100
62
205
1100
62
260
1120
61
320
1120
61
370
1090
63
400
LOW
CFM
TEMP. RISE
WATTS
1210
57
265
1240
55
340
1260
54
410
1260
54
470
1130
61
430
MEDIUM LOW
NORMAL **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
1360
50
365
1390
49
445
1400
49
500
1360
50
535
1210
57
475
OFF
OFF
CFM
TEMP. RISE
WATTS
1360
50
355
1390
49
450
1400
49
520
1350
51
535
1180
58
465
OFF
NOTES:
** Factory setting
8
Pub. No. 22-1682-05-0802 (EN)
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
AIRFLOW
SETTING
(See Notes)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
SW 1
ON
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
1040
165
1040
220
1040
270
1030
320
1030
375
NORMAL
(400 CFM/TON)
CFM
WATTS
1210
235
1210
285
1230
360
1230
415
1230
475
3.0
3.5
4.0
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1340
390
1370
390
1400
465
1390
525
1370
580
LOW
(350 CFM/TON)
CFM
WATTS
1200
225
1220
280
1230
365
1250
425
1230
485
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1390
335
1430
425
1430
495
1430
560
1400
590
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1590
490
1590
575
1590
625
1580
685
1420
615
ON
LOW
(350 CFM/TON)
CFM
WATTS
1370
325
1420
415
1430
490
1340
550
1410
595
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1640
515
1640
585
1640
655
1590
680
1420
615
ON
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1840
700
1840
780
1770
795
1630
725
1470
655
ON
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
TUY100R9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity =
2nd Stage Capacity =
62,000
93,000
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
920
60
130
920
60
180
920
60
220
920
60
280
920
60
320
LOW
MEDIUM LOW
NORMAL **
HIGH
ON
ON
CFM
TEMP. RISE
WATTS
1020
54
165
1020
54
220
1020
54
260
1010
55
310
1000
56
365
OFF
ON
ON
OFF
OFF
ON
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
1160
48
220
1160
48
260
1160
48
325
1160
48
390
1150
48
430
CFM
TEMP. RISE
WATTS
1350
41
320
1380
40
400
1400
40
470
1400
40
540
1390
40
585
OFF
ON
CFM
TEMP. RISE
WATTS
1290
67
275
1290
67
355
1330
65
430
1340
64
490
1320
65
545
LOW
CFM
TEMP. RISE
WATTS
1410
61
3561
1460
59
455
1460
59
520
1460
59
590
1370
63
590
MEDIUM LOW
NORMAL **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
1640
53
530
1640
53
590
1640
53
660
1600
54
695
1410
61
620
OFF
OFF
CFM
TEMP. RISE
WATTS
1970
44
855
1920
45
895
1780
48
820
1660
52
760
1520
57
695
OFF
NOTES:
** Factory setting
Pub. No. 22-1682-05-0802 (EN)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
TUY120R9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
AIRFLOW
SETTING
(See Notes)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
SW 1
OFF
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
1210
220
1210
270
1220
325
1230
400
1230
445
NORMAL
(400 CFM/TON)
CFM
WATTS
1400
305
1440
390
1450
465
1450
510
1410
560
3.5
4.0
5
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1590
425
1600
520
1610
600
1600
645
1380
575
LOW
(350 CFM/TON)
CFM
WATTS
1390
305
1400
375
1430
445
1440
515
1420
565
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1620
420
1650
530
1670
595
1640
660
1480
600
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1840
600
1830
690
1820
765
1670
700
1490
620
ON
LOW
(350 CFM/TON)
CFM
WATTS
1800
570
1780
630
1780
705
1700
695
1530
615
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
2050
845
2010
875
1860
805
1710
735
1530
655
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
2160
995
2040
935
1920
875
1780
805
1620
730
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
TUY120R9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity =
2nd Stage Capacity =
74,000
112,000
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
1090
62
165
1120
60
225
1080
63
270
1070
63
310
1010
67
380
LOW
MEDIUM LOW
NORMAL **
HIGH
ON
ON
CFM
TEMP. RISE
WATTS
1210
56
220
1200
56
280
1200
56
330
1180
57
395
1160
58
455
OFF
ON
ON
OFF
OFF
ON
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
1340
50
295
1360
50
350
1370
49
425
1380
49
495
1330
51
535
CFM
TEMP. RISE
WATTS
1430
47
390
1570
43
490
1580
43
565
1570
43
625
1390
49
565
OFF
ON
CFM
TEMP. RISE
WATTS
1660
63
485
1690
62
590
1680
62
640
1640
64
675
1460
72
600
LOW
CFM
TEMP. RISE
WATTS
1870
56
675
1870
56
745
1810
58
770
1680
62
715
1490
70
625
MEDIUM LOW
NORMAL **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
2060
51
880
1990
53
890
1850
57
810
1710
61
750
1530
68
665
OFF
OFF
CFM
TEMP. RISE
WATTS
2200
48
1030
2090
50
965
1940
54
895
1790
58
830
1640
64
750
OFF
NOTES:
** Factory setting
10
Pub. No. 22-1682-05-0802 (EN)
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
SCHEMATIC DIAGRAMS FOR GAS FURNACES
TUY060,080,100,120R9V-V
LEGEND
From Dwg. 21D341111 P03
Pub. No. 22-1682-05-0802 (EN)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Field
Wiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING
TO 115 V 1 PH.,
60 HZ., POWER
SUPPLY PER
LOCAL CODES
HUM SEE
NOTE 5
EAC SEE
NOTE 5
From Dwg. 21B341127 Rev. 0
FIELD WIRING DIAGRAM FOR 2 STAGE HEATINGTHERMOSTAT
TO 115 V 1 PH.,
60 HZ., POWER
SUPPLY PER
LOCAL CODES
HUM SEE
NOTE 5
EAC SEE
NOTE 5
From Dwg. 21B341126 Rev. 0
12
Pub. No. 22-1682-05-0802 (EN)
Download from Www.Somanuals.com. All Manuals Search And Download.
Field
Wiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING
(OUTDOOR SECTION WITHOUTTRANSFORMER)
From Dwg. 21B341125 Rev. 1
FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING
(OUTDOOR SECTION WITHOUTTRANSFORMER)
From Dwg. 21B341124 Rev. 1
Pub. No. 22-1682-05-0802 (EN)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Field
Wiring
FIELD WIRING DIAGRAM FOR 2 STAGE HEATINGTWO STAGE COOLING
(OUTDOOR SECTION WITHOUTTRANSFORMER)
TO 115 V 1 PH.,
60 HZ., POWER
SUPPLY PER
LOCAL CODES
HUM SEE
NOTE 5
EAC SEE
NOTE 5
From Dwg. 21B341128 Rev. 0
14
Pub. No. 22-1682-05-0802 (EN)
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
Pub. No. 22-1682-05-0802 (EN)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
File No.
PL-UN-FURN-TDD-D-1 3/98
TDD-D-1 8/95
P. I .
Supersedes
Trane
A business of American Standard Companies
Since Trane has a policy of continuous product improvement, it reserves the right to change design and
specifications without notice.