				SUUNTO COMBO CONSOLES   
					The Suunto combo consoles for recreational use allow you to create a   
					personal console according to your own specific needs. Analog gauges,   
					dive computers and compasses fit together like building blocks.   
					Suunto console compasses   
					The Suunto SK-8 is available in two models, each with northern and   
					sothern hemisphere balancing options. The SK-8 Console Mount, front   
					attaches to the top of the combo module or the Cobra dive computer.   
					The SK-8 Console Mount, back attaches to the back side of the combo   
					module.   
					Suunto mechanical gauges   
					There are four Suunto SM-16 depth gauge models: 45 m, 70 m, 150 ft   
					and 230 ft.   
					There are two Suunto SM-36 pressure gauge models: 300 bar and 4000   
					psi.   
					Adding SM-16 and SM-36 guages to combos always requires a CB-In-   
					Line module.   
					1 
					wnload from Www.Somanuals.com. All Manuals Search And Downlo   
				SK-8   
					CB-TWO   
					+ 
					= 
					CB-ONE   
					+ 
					CB-DOUBLE   
					SK-8   
					CB-TWO-IN-LINE   
					SK-8   
					+ 
					CB-DOUBLE-IN-LINE   
					CB-THREE-IN-LINE   
					CB-IN-LINE   
					= 
					+ 
					CB-ONE   
					+ 
					SK-8   
					2 
					wnload from Www.Somanuals.com. All Manuals Search And Downlo   
				1 
					2 
					3 
					(3)   
					5 
					4 
					(5)   
					1. CB-ONE module front cover with SM-36 pressure gauge in place   
					(see section CB-ONE Module assembly)   
					2. CB-IN-LINE module front cover   
					3. CB-end piece or SK-8 Console Mount, front compass (optional)   
					4. CB-IN-LINE module back cover with instrument   
					5. CB-ONE module back cover or SK-8 Console Mount, back   
					compass (optional)   
					3 
					wnload from Www.Somanuals.com. All Manuals Search And Downlo   
				CB-ONE MODULE ASSEMBLY   
					The CB-ONE Module is designed to fit the Suunto SM-36 analog   
					pressure gauges.   
					Before assembling the CB-ONE module the hose cover needs to be   
					fitted on the pressure hose. The hose cover ensures that the SM-36   
					pressure gauge fits properly on the CB-ONE module.   
					If the Suunto Quick Release is used, see section ‘CB-ONE module   
					assembly with Quick Release.’   
					After attaching the hose cover the pressure hose and gauge are   
					assembled on the CB-ONE front cover according to the picture.   
					After the pressure gauge is in place, the CB-ONE back cover (or   
					alternatively the CB-71/SK-8 Console Mount, back compass) is attached   
					with four screws.   
					4 
					wnload from Www.Somanuals.com. All Manuals Search And Downlo   
				CB-ONE MODULE ASSEMBLY WITH QUICK RELEASE   
					If the Suunto Quick Release is used, the hose cover should be attached   
					on the high pressure hose below the female end of the Quick Release.   
					The male end is attached to the pressure gauge which is then fitted   
					onto the CB-ONE front cover as shown below.   
					CB-IN-LINE MODULE ASSEMBLY   
					The CB-IN-LINE module fits the Suunto Vyper, Vyper Air, HelO2 and   
					Zoop dive computers or the SM-16 depth gauge.   
					The Vyper locks into place on the IN-LINE module back cover. For the   
					other instruments, lugs on the back cover aid alignment.   
					5 
					wnload from Www.Somanuals.com. All Manuals Search And Downlo   
				SUUNTO ZOOP NOVO AND VYPER NOVO   
					COMBO MOUNT ASSEMBLY   
					The combo mount for Suunto Zoop Novo and Vyper Novo locks into   
					place on the IN-LINE module back cover.   
					6 
					wnload from Www.Somanuals.com. All Manuals Search And Downlo   
				BEFORE USE   
					Depth gauge   
					Before diving, check the position of the depth indicating pointer.   
					Atmospheric conditions (altitude, temperature) may cause   
					misalignment. Turn the adjustment screw located on the right side of   
					the depth gauge to align the pointer to zero. The adjustment is to be   
					made at the temperature of usage. Repeated unnecessary adjustments   
					may cause excessive wear to the seals and eventual leakage.   
					CAUTION!   
					Do not attempt to adjust the water entry port located at the left   
					side of gauge. Tampering with the port can cause damage to   
					internal components. Do not pressure test gauge in air. Always   
					immerse the gauge in water while pressure testing it.   
					Pressure gauge   
					The hose has an end fitting with 7/16” 20 UNF-thread. If your   
					regulator has a different thread size in the high pressure (HP-output)   
					port, ask your dealer for the correct adapter. Always inspect the   
					O-ring at the male thread to be sure it is clean and undamaged before   
					connecting it to the regulator.   
					Always turn your air supply on slowly. Always turn the pressure gauge   
					dial face away from your face when turning on the air supply.   
					Do not overtighten the hose at the gauge. The fitting is pressure   
					resistant even when tightened with fingers.   
					SERVICE AND CARE   
					The instruments must be serviced by an authorized dealer every   
					second year or after 200 dives (whichever comes first).   
					Avoid subjecting the gauges to excessive shocks such as dropping   
					or hitting against an immovable object. Do not subject the gauges   
					to pressures beyond their maximum range. Temperature extremes   
					can be damaging. In general, the gauges should not be exposed to   
					temperatures to which you would not expose yourself.   
					7 
					wnload from Www.Somanuals.com. All Manuals Search And Downlo   
				CAUTION: After use, rinse the gauges or the console with fresh water and   
					store them out of direct sunlight, in a dry place at room temperature.   
					CAUTION: Do not attempt to clean the gauges with anything other than   
					water. Use of cleaning agents or compressed air can cause permanent damage.   
					Inserting objects into the water entry port of the depth gauge or the pressure   
					relief valve opening of the pressure gauge can damage internal components.   
					Before prolonged storage, the instruments should be removed from   
					the console, rinsed with fresh water and stored separately.   
					CAUTION: Do not attempt to disassemble the gauges. Special tools and   
					training are required.   
					8 
					wnload from Www.Somanuals.com. All Manuals Search And Downlo   
				TECHNICAL SPECIFICATIONS   
					The Suunto SM-16 complies with EN 13319. The tolerances are:   
					At 3m   
					+0.8 / -0.4 m   
					+0.8 / -0.4 m   
					0.8 m   
					At 6m   
					At 9m   
					At 15m   
					At 30m   
					At 45m   
					At 60m   
					+1/ -1.2 m   
					+1/ -1.2 m   
					+1/ -1.5 m   
					+1 / -1.5 m   
					The Suunto SM-36 complies with EN 250. The tolerances are:   
					At 40 bar   
					At 100 bar   
					At 200 bar   
					At 300 bar   
					5 bar   
					10 bar   
					10 bar   
					10 bar   
					SM-16   
					SM-36   
					Operating temperature 0° to 40° C (32° to 104° F)   
					Operating temperature 0° to 40° C (32° to 104° F)   
					9 
					wnload from Www.Somanuals.com. All Manuals Search And Downlo   
				SUUNTO CUSTOMER SUPPORT   
					
					
					2. AUSTRALIA +61 1800 240 498   
					AUSTRIA   
					CANADA   
					CHINA   
					FINLAND   
					FRANCE   
					GERMANY   
					ITALY   
					+43 720 883 104   
					+1 800 267 7506   
					+86 010 84054725   
					+358 9 4245 0127   
					+33 4 81 68 09 26   
					+49 89 3803 8778   
					+39 02 9475 1965   
					+81 3 4520 9417   
					+31 1 0713 7269   
					+64 9887 5223   
					+7 499 918 7148   
					+34 91 11 43 175   
					+46 8 5250 0730   
					+41 44 580 9988   
					+44 20 3608 0534   
					+1 855 258 0900   
					JAPAN   
					NETHERLANDS   
					NEW ZEALAND   
					RUSSIA   
					SPAIN   
					SWEDEN   
					SWITZERLAND   
					UK   
					USA   
					© Suunto Oy 11/2005, 09/2006, 11/2011, 3/2015, 4/2016. All rights   
					reserved.   
					Suunto is a registered trademark of Suunto Oy.   
					wnload from Www.Somanuals.com. All Manuals Search And Downlo   
				 | 
Sharp Copier AL 1451 User Manual
Sharp Microscope Magnifier DK KP82PH User Manual
SonicWALL Humidifier TZ 180 User Manual
Sony Clock Radio ICF CD837L User Manual
Sony CRT Television KP 48V80 User Manual
Sony Video Game Controller 10037 User Manual
SOYO Computer Hardware SY P4I845PE User Manual
Speco Technologies Security Camera CNC5915DNVW User Manual
Sterling Power Products Battery Charger DAI 1500C 12xx User Manual
Tannoy Speaker ic6 DC User Manual