The S&G X D-Drive lock combines ease of operation with
• All codes end with #. This signals the
lock that you have finished entering all
digits of the code.
security and flexibility. Its advanced electronic circuit design
makes it easy to open and easy to change codes. Follow these
instructions carefully to get the best possible use from your lock.
• If you pause more than 10 seconds
IntroductIon
between button presses when entering
a code, the lock will assume you do not
want to continue, and it will reset itself
to the original code. To open the lock,
©
03
™
• This S&G X D-Drive lock is shipped from the factory in
multi-user mode with a factory master code of 1 2 3 4 5 6
#. This code can be used to open the lock and set or change
codes. You should set the lock to your own, unique master
code.
begin the code entry sequence once again from the first step.
• If you realize you have pressed an incorrect button when
entering a code, press ✽ or simply pause ten seconds or more,
then begin entering your code again.
• Your lock can be programmed with a management reset code
that can be used to regain control of the lock in the event the
master code is lost. The management reset code must be
programmed into the lock before the master code is changed
for the first time.
©
03
• If five incorrect codes are entered in a row, the S&G X D-
™
Drive lock will shut down for a period of ten minutes. This
is a security feature. Entering a code during this period will
result in two long error tones (braps). Pressing any buttons
during the lockout period will not affect the penalty timer.
After ten minutes, the lock should operate normally.
• At your discretion, the lock can be set to accept a supervisor
code, up to seven different user codes, and a time delay
override code. The master code holder and the supervisor
code holder (if a supervisor code is set) are responsible
for maintaining the number of active users programmed into
each lock. The master code holder and the supervisor code
holder can create and delete user codes.
The lock can also go into the lockout period during
programming if it interprets an incorrect programming
sequence as five or more consecutive incorrect code entries.
If the lock emits two long error tones (braps) during repeated
programming attempts, it is in lockout mode. Wait ten
minutes, then try again.
• The master code is designated as code #0. The supervisor
code (if set) is designated as code #1. The user codes (if
set) are designated by user position numbers 2, 3, 4, 5, 6, 7,
and 8. The time delay override code (if set) is designated as
code #9.
• For UL installations, the maximum number of working codes
allowed is one.
• Personal data which can be directly related to a code holder,
such as a birthdate, should not be used in making up a lock
code. Avoid codes which can be easily guessed.
• Each time a button is pressed, the lock acknowledges it
by sounding a “beep,” and the LED on the keypad will light
momentarily as the “beep” sounds. If it does not, check your
battery (or batteries) to make sure it is fresh and connected
properly, then try again.
• After the lock is changed to a new code, the lock function
must checked by locking and unlocking it several times with
the container door open. Make sure it functions correctly
before closing the door.
• All codes must contain six digits or six letters. Any digit or
letter can be used as many times as you wish. For instance,
the following codes (while not recommended) will operate the
lock: 5 5 5 5 5 5 # OR J J J J J J #
Note: This lock has been Listed by Underwriters Laboratories for use with the following
S&G keypad(s): 6130-2XX and 6130-3XX
Sargent & Greenleaf, Inc.
Sargent & Greenleaf S.A.
9, chemin du Croset
1024 Ecublens, Switzerland
Phone +41-21 694 34 00
FAX +41-21 694 34 09
A Wholly Owned Subsidiary of Stanley Security Solutions, Inc.
PO Box 930, Nicholasville, Kentucky 40356 USA
Phone (859) 885-9411
Phone (800) 826-7652
FAX (859) 887-2057
FAX (800) 634-4843
Document 630-735
Revised 7/25/06
© Copyright 2006, Sargent & Greenleaf
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating instructiOns
S&G® Z03 D-Drive™ Multi-User Electronic Safe Lock
2005 Series
the time delay, for the opening code at the end of the time delay,
openIng the Lock
or for both codes. The silent alarm signal will be sent each time a
duress code is entered. (Note: Lock codes 4 - 8 are not available if the
duress feature is turned on. If time delay override is disabled or not used, lock
code 9 is available.)
➥WIth no tIme deLay
A valid code is needed to open the lock. This is how to open the
lock with the original factory master code of 1 2 3 4 5 6. Make
sure the keypad is turned counterclockwise to stop.
➥usIng a tIme deLay overrIde code
Enter 1 2 3 4 5 6
#
This lock is capable of using a time delay override code if it
was originally ordered with this feature, and if the TDO (time delay
override) feature is enabled. As the name implies, the time delay
override code can be used to open the lock without waiting for
the time delay period to expire. This is useful for armored car cash
pickups. The TDO code only works when your lock uses a time delay.
Then, within six seconds, turn the keypad clockwise about
70 degrees, until it comes to a positive stop. Do not put any
pressure on the safe handle until after the keypad has been
turned. To re-lock the S&G X D-Drive , turn the keypad back
counterclockwise to stop. When the mechanism re-locks, it will emit a
double beep consisting of a low tone followed by a slightly higher tone. If
you do not hear the double beep, the mechanism is not properly locked.
©
03
™
Your lock is capable of two different types of time delay override.
Single control time delay override allows the TDO code holder to
simply enter his code to open the lock. The time delay period is
completely bypassed. For example, if the TDO code is 9 8 7 6 5 4,
it would only be necessary to press the following keypad buttons to
unlock the safe.
➥WIth tIme deLay actIve
Time delay enforces a waiting period between entry of the first
code and opening of the safe. This feature is a proven deterrent to
armed robbery. Any valid lock code can be used to start the time
delay. When this code is entered, the lock beeps three times and
begins counting down the delay period. The lock will beep once
every ten seconds during the delay period. At the end of the delay
period, the lock will beep ten times rapidly. Enter a valid code
for the lock. After the code is entered, the lock will release for six
seconds to allow you to turn the keypad and open the safe.
Enter 9 8 7 6 5 4 #
The other type of time delay override is dual control TDO. To use
this type of time delay override, it is necessary to start the lock’s
time delay by entering any valid code other than the TDO code.
Then, within one minute, enter the TDO code. The lock will open
immediately. This type of time delay override places a secondary
control on the TDO code holder, adding a measure of extra
security. The following example uses the factory set master code
(1 2 3 4 5 6) to start the time delay, then a TDO code of 9 8 7 6 5
4 is used to open the lock without waiting for the time delay period
➥WIth duress actIve
Duress , sometimes referred to as “silent alarm,” is a feature that
causes an alarm signal to be sent when a code is entered. This
capability must be enabled in the lock, and an optional duress
module must be added to the lock and connected to an existing
alarm system for this feature to work.
to expire.
♪♪♪
Enter 1 2 3 4 5 6
#
9 8 7 6 5 4 #
➥usefuL operatIng InformatIon
A duress code (one which triggers the alarm signal) is simply
any valid lock code with 1 added to the last digit. For instance, if
you create a user code of 2 2 2 2 2 2, the duress version of this
code is 2 2 2 2 2 3. This code is valid for operating the lock and
simultaneously triggering the duress alarm signal.
The lock will emit a long error tone if an incorrect or incomplete
code is entered. If five or more incorrect codes are entered in
a row, the lock will go into a ten-minute lockout period. If you
attempt to enter a code during this lockout period, two long error
tones will be heard. Simply wait ten minutes, then attempt to
operate the lock again. The lockout period cannot be bypassed. You
must wait for it to time out.
When the duress feature is turned on, lock codes 0, 1, 2, 3, and
9 are capable of triggering the silent alarm signal. If a time delay
is programmed into the lock, a duress code can be used to start
© Copyright 2006, Sargent & Greenleaf
Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating instructiOns
S&G® Z03 D-Drive™ Multi-User Electronic Safe Lock
2005 Series
changIng, creatIng, deLetIng codes
➥changIng your oWn code
Any code holder can change his own code. The process is:
➥creatIng a management reset code
♪♪♪♪♪
♪♪♪
♪♪♪
2 2 ✽ OLD CODE #
NEW CODE # NEW CODE #
A management reset code can only be created before the lock's
master code is changed for the first time. It can later be used to
reset the lock in the event the master code is lost. Resetting the
lock this way deletes the time delay override code, supervisor
code, and all user codes, and it allows you to set a new master
code at the same time. This reset does not affect the time delay
or opening window, duress, audit trail, or lock access method.
For example, changing a user code of 2 2 2 2 2 2 to a new code
of 2 4 6 8 3 3 would be accomplished as follows:
♪♪♪♪♪
♪♪♪
♪♪♪
2 2 ✽ 2 2 2 2 2 2 #
2 4 6 8 3 3 # 2 4 6 8 3 3 #
➥creatIng a neW code
The holder of the master code (position 0) can create new codes and
delete existing codes. The master code can also be used to set or
delete a time delay override code.
It is important to note that the management reset code can only
be set or changed before the lock’s master code is changed for
the first time. It is recommended that the management reset
code be stored off premises as an additional security measure.
The holder of the supervisor code (position 1) can create and delete
user codes and the time delay override code. The supervisor
code cannot be used for any operations affecting the master code.
The management reset code is different from other lock codes.
It is composed of seven digits, two of which are pressed at the
same time. This two-digit pair must be either 0/1 or 0/3. For
instance, a management reset code could be 3 6 2 [0/3] 1 9.
The 0 and 3 must be pressed simultaneously. The 0/1 or 0/3 can
be located anywhere in the management reset code, and the
digits 0, 1, and 3 can also be used as individual digits anywhere
in the code. For instance, 0 3 1 0 [0/1] 0 would be an acceptable
MRC. Only the 0/1 in brackets would be pressed simultaneously.
There are several code storage positions in the lock, designated 0
through 9. They store the following types of codes:
position 0 — master code
position 1 — supervisor code
positions2 through 8 — user codes
position 9 — time delay override code
Here is the process for creating a supervisor code.
The lock’s MRC (management reset code) may have been preset
at the factory. A factory MRC can be set or changed using the
following procedure.
♪♪♪♪♪ ♪♪♪
7 4 ✽ master code #
1 #
♪♪♪
♪♪♪
new supervisor code # new supervisor code #
♪♪♪♪♪
♪♪♪
♪♪♪
To create a new user code, use the following sequence. In this
example, a new user code is being created in position 5.
6 7 ✽ 1 2 3 4 5 6 #
NEW MRC # NEW MRC #
♪♪♪♪♪
➥usIng a management reset code
7 4 ✽ master code or supervisor code #
♪♪♪
♪♪♪
♪♪♪
Use the MRC only when you have lost or forgotten the master
code for the lock. You should make up a new six digit master
code before implementing the reset. Following is the procedure.
5
(position number)
#
new user code # new user code #
User codes can be set in any storage position from 2 through 8.
♪♪♪♪♪
♪♪♪
To create a new time delay override code, see the time delay
section.
6 7 ✽ MRC #
NEW 6-DIGIT MASTER CODE #
♪♪♪
NEW 6-DIGIT MASTER CODE #
After the final three beeps, indicating completion of the reset,
the lock will beep once for each time the MRC has been used,
including the current usage.
Page 4
© Copyright 2006, Sargent & Greenleaf
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating instructiOns
S&G® Z03 D-Drive™ Multi-User Electronic Safe Lock
2005 Series
➥deLetIng an exIstIng code
➥changIng the openIng WIndoW duratIon
The holder of the master code (position 0) can delete any other code. The length of the opening window period is set as follows. The period
The master code cannot be deleted under any circumstances.
can be anywhere from 1 to 10 minutes.
♪♪♪♪♪
♪♪♪
The holder of the supervisor code (position 1) can delete user
codes. The supervisor code cannot be used to delete the master
code or itself.
7 4 ✽ master code #
0 1 #
♪♪♪
length of desired opening window period #
length of desired opening window period #
♪♪♪
Here is the process for deleting a supervisor code.
➥managIng tIme deLay overrIde
♪♪♪♪♪ ♪♪♪ ♪♪♪ ♪♪♪
7 4 ✽ master code #
1 #
#
#
This optional feature determines whether or not you can override the
time delay waiting period. There may be special circumstances that
make it desirable to open the lock before time delay expires, such as
during cash pickups by an armored car service. Time delay override
only works when the lock is being operated in time delay mode. Your
lock is capable of two different types of time delay override. Single
control time delay override allows the TDO code holder to simply enter
his code to open the lock. The delay period is completely bypassed.
To delete a user code in position 5, use the following sequence.
♪♪♪♪♪ ♪♪♪ ♪♪♪ ♪♪♪
7 4 ✽ master code or supervisor code #
5 #
#
#
To delete a time delay override code, see the time delay section.
managIng tIme deLay
➥creatIng, changIng, deLetIng a tIme deLay
The other type of time delay override is dual control TDO. To use this
type of time delay override, it is necessary to start the lock’s time
delay by entering any valid code other than the TDO code. Then, within
Time delay is a security feature that enforces a predetermined waiting
period between the entering of a valid lock code and the actual
opening of the lock. The delay period can be set from 1 to 99 minutes. one minute, enter the TDO code. The lock will open immediately. This
type of time delay override places a secondary control on the TDO
code holder, adding a measure of extra security.
The opening window is a period of time immediately after the time
delay during which you can enter a valid lock code to open the lock.
The factory default opening window is 2 minutes, but it can be
changed to any value between 1 and 10 minutes.
➥turnIng sIngLe controL tIme deLay overrIde on
If your lock was ordered with time delay override capability, single
control TDO can be turned on as follows.
Note: Changes to an existing time delay or opening window can only be
accomplished during the opening window period. This means you must enter
a valid operating code for the lock, wait for the time delay to expire, then
begin the appropriate programming sequence rather than opening the lock.
♪♪♪♪♪ ♪♪♪ ♪♪♪
4 6 ✽ master code #
2 # 2 #
The programming sequence for setting, changing, or deleting a
time delay period is as follows. The period can be anywhere from
1 to 99 minutes.
➥turnIng duaL controL tIme deLay overrIde on
If your lock was ordered with time delay override capability, dual
control TDO can be turned on as follows.
♪♪♪♪♪ ♪♪♪ ♪♪♪
♪♪♪♪♪
♪♪♪
7 4 ✽ master code #
0 0 #
♪♪♪
♪♪♪
length of desired time delay period # length of desired time delay period #
4 6 ✽ master code #
1 # 1 #
To delete a time delay, enter 0 for the desired time delay length.
➥turnIng tIme deLay overrIde off
♪♪♪♪♪ ♪♪♪ ♪♪♪
4 6 ✽ master code #
0 # 0 #
When time delay override is turned off, the time delay override
code is erased. PIN position #9 can now be used to store a
regular user code.
© Copyright 2006, Sargent & Greenleaf
Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating instructiOns
S&G® Z03 D-Drive™ Multi-User Electronic Safe Lock
2005 Series
After this programming procedure is completed, the lock will be
disabled. If a valid code is entered, the lock will emit a double
beep, but will not open.
➥creatIng the tIme deLay overrIde code
The TDO code is located in position 9. It is programmed as follows.
♪♪♪♪♪
♪♪♪
7 4 ✽ master code or supervisor code #
9
#
♪♪♪
(♪po♪s♪ition number)
➥enabLIng the Lock In management/empLoyee access mode
new TDO code # new TDO code #
Before valid codes can be entered to open the lock, it will be
necessary to perform the following procedure.
➥changIng the tIme deLay overrIde code
♪♪♪♪
An existing TDO code can only be changed by the holder of that code,
as follows.
5 5 ✽ master code or supervisor code #
Note that the lock emits four beeps to indicate that it can now
be opened by any valid code.
♪♪♪♪♪
♪♪♪
♪♪♪
22 ✽OLDTDOCODE# NEWTDOCODE# NEWTDOCODE#
➥deLetIng the tIme deLay overrIde code
➥dIsabLIng the Lock In management/empLoyee access mode
The TDO code is deleted as follows.
To make the lock inoperable by any code, simply repeat the same
programming procedure.
♪♪♪♪♪
♪♪♪ ♪♪♪ ♪♪♪
7 4 ✽ master code or supervisor code #
9
(position number)
#
#
#
♪♪
5 5 ✽ master code or supervisor code #
management/empLoyee access mode
Note that the lock emits two beeps to indicate that it is now
disabled, and cannot be opened by any code.
➥types of management/empLoyee access
Management/employee access is an alternate way to operate this lock,
to meet special security needs. Your lock can be programmed so that
during everyday operation, the master code holder or supervisor
code holder can enable the lock. It can then be opened using any valid
lock code (master, supervisor, or user code), until it is disabled.
There are two varieties of the enable/disable function.
This sequence simply toggles the lock on and off to determine
whether or not it can be opened by the master code, supervisor
code, or any user code. When the lock is disabled, it will emit a
double beep when a code is entered, but will not open.
➥LettIng users dIsabLe the Lock In management/empLoyee access mode
In the first version, only the holder of the master code and
supervisor code can enable and disable the lock.
Only the holder of the master code or supervisor code can enable
the lock, but there may be circumstances under which you want
user code holders to also be able to disable the lock. To allow
this, perform the following procedure.
In the second version, user code holders can also disable the lock.
The master code and supervisor code holders are the only persons
who can both enable and disable the lock.
♪♪♪♪♪ ♪♪♪ ♪♪♪
5 6 ✽ master code #
1 # 1 #
Now, after the lock is enabled by the master code or supervisor
code holder, any user code holder can disable it by entering the
following sequence.
➥programmIng the Lock for management/empLoyee access mode
Your lock can be programmed so that the master code holder or
supervisor code holder can use his code to enable the lock for
opening by any valid lock code. When either the master code or
supervisor code is again to toggle the lock, it can no longer be
opened. This process can be repeated whenever appropriate.
♪♪♪♪♪ ♪♪♪ ♪♪♪
♪♪
5 5 ✽ any user code #
When the lock is disabled, it will emit a double beep when a
code is entered, but will not open.
3 2 ✽ master code #
2 # 2 #
Page 6
© Copyright 2006, Sargent & Greenleaf
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating instructiOns
S&G® Z03 D-Drive™ Multi-User Electronic Safe Lock
2005 Series
➥canceLLIng user dIsabLe In management/empLoyee access mode
managIng audIt traIL
If you decide user code holders should no longer have the ability
to disable the lock, perform the following procedure.
♪♪♪♪♪ ♪♪♪ ♪♪♪
➥capturIng an audIt traIL
Your lock must have been ordered with this option. Using the audit
trail feature also requires an optional keypad extension (S&G part
number 6101-201), as well as an audit trail software kit (S&G part
number 6103-100). The lock records the last 63 events, in the order
they occurred. After the 63rd event, the lock overwrites the oldest
event with the new one, so you always have access to the most recent
63 events. To download the audit trail through the optional keypad
extension, hold the Dallas iButton key provided in the audit trail kit to
the receptacle in the keypad extension, and enter the following.
5 6 ✽ master code #
0 # 0 #
User code holders will no longer be able to disable the lock,
although the master code holder and supervisor code holder will
still have the ability to do so.
➥takIng the Lock out of management/empLoyee access mode
If you no longer want the lock to function in the management/
employee access mode, enter the following sequence.
♪♪♪♪♪ ♪♪♪ ♪♪♪
2 8 ✽ master code #
3 2 ✽ master code or supervisor code #
1 # 1 #
The lock will beep three times when the download is complete.
You may then remove your iButton key from the keypad
extension’s receptacle. The information now stored in the key is
a copy of what is in the lock. The lock’s audit information is not
erased in the download process.
The lock will now operate on any valid code at any time.
managIng duress
➥turnIng duress on
If your lock was ordered with time duress capability and an optional
duress module is installed, the feature can be turned on as follows.
♪♪♪♪♪ ♪♪♪ ♪♪♪
3 8 ✽ master code #
1 # 1 #
➥turnIng duress off
The duress feature can be turned off as follows.
♪♪♪♪♪ ♪♪♪ ♪♪♪
3 8 ✽ master code #
0 # 0 #
➥verIfyIng duress
If duress is enabled, you can tell if the lock has sent a silent alarm.
Fifteen minutes or more after a duress signal has been sent, press
and hold down the ✽button for at least four seconds. The lock will
emit a continuous alternating series of high and low pitch beeps
to indicate that a duress signal has been sent. Reset the duress
indication by entering the lock’s master code within one minute after
the verification signal ends.
Page 7
© Copyright 2006, Sargent & Greenleaf
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating instructiOns
S&G® Z03 D-Drive™ Multi-User Electronic Safe Lock
2005 Series
LoW battery condItIon
InformatIon tabLes
©
03
™
The S&G X D-Drive lock uses a 9-volt alkaline battery. We
recommend Duracell® brand. If the battery in your lock needs to
be replaced, twenty consecutive beeps will be heard after the
last number of the code and # have been pressed. The battery
will have to be replaced before the lock can be opened.
➥determInIng your Lock’s mode of operatIon
Enter 4 3 ✽
The ensuing beep pattern will tell you if your lock is configured
in single user, multiple user, or dual control mode.
BEEP PATTERN
Note: If the battery is getting low, but the lock still has enough
power to function, it will emit five sets of two short, high pitch
beeps before opening. This is an early signal that battery failure
is approaching.
1ST SET OF
BEEPS
4
4
4
2ND SET OF
BEEPS INDICATES
MODE
1 BEEP INDICATES
SINGLE USER
2 BEEPS INDICATE
MULTIPLE USER
3 BEEPS INDICATE
DUAL CONTROL
➥beep pattern reference tabLe
Lock Activity
Beep Pattern Emitted
3 short high pitch beeps
1 long continuous beep
2 long continuous beeps
A code has been entered to start a time delay
An incorrect code has been entered
A code has been entered during a penalty
lockout period
Time delay countdown period in effect
Time delay countdown finished
Opening window period in effect
Low battery warning
1 short high pitch beep every 10 seconds
10 short high pitch beeps
2 short high pitch beeps every 6 seconds
5 sets of 2 short high pitch beeps
Battery too low for lock to function
Bolt extension signal
20 short high pitch beeps (lock does not open)
1 low/high beep sequence
3 high pitch beeps
Optional audit trail download completion
Lock is enabled in Management/Employee mode
4 high pitch beeps
Lock is disabled in Management/Employee mode 2 low pitch beeps
➥QuIck reference tabLe
Command Function
2 2 ✽
2 8 ✽
3 8 ✽
4 3 ✽
4 6 ✽
7 4 ✽
7 7 ✽
3 2 ✽
5 5 ✽
5 6 ✽
6 7 ✽
Any code holder changes his own six-digit code
Master code holder downloads the event audit trail
Master code holder enables or disables the optional duress feature
Anyone identifies the lock type
Master code holder enables or disables the optional time delay override feature
Master code and supervisor code holder sets or deletes codes
Anyone interrogates the lock to identify used and unused code positions
Master code holder enables or disables management/employee mode
Enable and disable the lock in management/employee mode
Master code holder determines whether or not user code holders can disable the lock in management/employee mode
Set and use the management reset code (MRC)
Page 8
© Copyright 2006, Sargent & Greenleaf
Download from Www.Somanuals.com. All Manuals Search And Download.
Battery changing instructiOns
S&G® Z03 D-Drive™ Multi-User Electronic Safe Lock
2005 Series
LoW battery condItIon
©
03
™
The S&G X D-Drive lock uses one 9-volt alkaline battery,
which is housed in the keypad. We recommend Duracell® brand.
If the battery needs to be replaced, the lock will emit five
double-beeps whenever it is opened. If this signal is ignored
and the battery becomes so weak that it will no longer operate
the lock, you’ll hear twenty quick beeps when you enter a code,
but the lock will not open. You will have to replace the battery
before your lock can be opened.
Figure 1
Figure 2
Figure 3
battery repLacement procedure
Always perform a battery change with the container door open.
The lock will NOT forget your code(s) during battery change.
The circuitry is designed to hold this information for extended
periods of time even if there are no batteries installed. Codes
are stored in non-volatile memory.
Step 1—Pull the yellow, spring-loaded tab at the top of the
keypad (Figure 1) toward you slightly. It is not meant to separate
from the keypad. Once it’s pulled forward, carefully turn the
keypad ring counterclockwise to stop. Then pull the ring away
from its base far enough to expose the battery compartment.
Step 2—Put your finger in the battery compartment, and
carefully pull out the battery cables (Figure 2). There should be
enough slack to allow you to pull the connector and old battery
outside the compartment. Disconnect the old battery.
Step 3—S&G strongly recommends Duracell® brand alkaline
batteries. No matter what brand is used, the battery must be
alkaline. Align the battery and connector terminals, and snap
the battery to the connector (Figure 3).
© Copyright 2006, Sargent & Greenleaf
Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Battery changing instructiOns
S&G® Z03 D-Drive™ Multi-User Electronic Safe Lock
2005 Series
Step 4—Carefully slide the battery behind the keypad, into the
cavity that is designed to hold it (Figure 4). Be sure the battery
has dropped all the way to the bottom of the cavity.
Step 5—Gently place any excess wire into the cavity. Make sure
it is not in a position to be caught between the keypad ring and
the keypad base when the ring is pushed back against the base
(Figure 5).
Step 6—Once the wires are safely positioned out of harm’s
way, push the keypad ring back up against the base, then turn
it clockwise until the yellow tab snaps back into its normal
position (Figure 6).
Figure 4
Figure 5
Figure 6
Check your lock operation at least three times with the container
door open before closing it.
Page 10
© Copyright 2006, Sargent & Greenleaf
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
Seller warrants that for one year from the date of shipment from Seller’s point of manufacture, the goods shall be free from defects in material and workmanship,
provided the goods are normally and properly used according to the Seller’s written instructions.
THIS WARRANTY IS EXPRESSLY MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. S&G DOES NOT WARRANT THAT THE GOODS ARE
MERCHANTABLE OR FIT FOR ANY PARTICULAR PURPOSE EXCEPT AS EXPRESSLY PROVIDED HEREIN.
Seller’s entire liability and Buyer’s exclusive remedy in the event that the goods do not conform to the foregoing warranty shall be Seller’s repair or replacement of
the goods (including payment of freight costs to and from point of manufacture).
UNAUTHORIZED USE OF DIAL, DIAL RINGS, AND/OR SPINDLES NOT MANUFACTURED BY THE SELLER IN CONJUNCTION WITH ITS COMBINATION LOCK PRODUCTS
INVALIDATES THE WARRANTY.
SELLER SHALL HAVE NO LIABILITY FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT OR SPECIAL DAMAGES. SELLER DOES NOT WARRANT ITS LOCK PRODUCTS
TO BE IMPERVIOUS TO FORCIBLE OR SURREPTITIOUS ENTRY, AND SELLER SHALL HAVE NO LIABILITY FOR DAMAGE TO OR LOSS OF PROPERTY SOUGHT TO BE
PROTECTED BY ANY SUCH LOCK.
Sargent & Greenleaf, Inc.
A Wholly Owned Subsidiary of Stanley Security Solutions, Inc.
PO Box 930, Nicholasville, Kentucky 40356 USA
Phone (859) 885-9411
Sargent & Greenleaf S.A.
9, chemin du Croset
1024 Ecublens, Switzerland
Phone +41-21 694 34 00
FAX +41-21 694 34 09
Phone (800) 826-7652
FAX (859) 887-2057
FAX (800) 634-4843
Download from Www.Somanuals.com. All Manuals Search And Download.
|